CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
i
Volunteer Fire Chief Dies After Being Crushed Between Two Fire Trucks – Kansas
-
2010/08/23
Details:
-
Personal Author:
-
Corporate Authors:
-
Description:Death in the line of duty…A summary of a NIOSH fire fighter fatality investigation
On February 10, 2010, a 69-year-old male Fire Chief (the victim) died after being crushed between a parked tanker and a pumper being backed into the fire station. The fire fighter reported that he observed the Fire Chief outside of the station as he was backing the pumper into the station. The fire fighter then realized he had backed the pumper too close to the tanker parked inside of the station, pulled forward to reposition the pumper, and then finished backing it into the station. The fire fighter exited the pumper and yelled for the Chief. The Chief did not respond. When the fire fighter searched for the Chief he found him unconscious and unresponsive on the station floor next to the pump panel of the tanker. The fire fighter called 911 and started CPR on the Chief. Emergency medical services responded and the Chief was pronounced dead by the coroner at the scene. Contributing Factors: 1.) Inadequate policies for backing apparatus. 2.) Inadequate facility space for the number of apparatus. 3.) Inoperative backup warning system and possibly obscured side view mirror. Key Recommendations: 1.) Ensure that standard operating procedures are developed, implemented, and enforced on safe backing of fire apparatus and include adequate training to ensure fire fighter comprehension. 2.) Ensure that apparatus storage bays are well lit and have adequate room to store apparatus. 3.) Implement procedures for inspection, use, and maintenance of safety equipment used to assist in the backing of fire apparatus to ensure the equipment functions properly when needed. 4.) Ensure that fire apparatus drivers have unobstructed views from their rear view mirrors. 5.) Consider replacing fire apparatus more than 25 years old. 6.) Be aware of programs that provide assistance in obtaining alternate funding for replacing or purchasing fire apparatus and equipment and for facility modification.
-
Subjects:
-
Keywords:
-
FACE - Firefighter:
-
Series:
-
DOI:
-
Publisher:
-
Document Type:
-
Genre:
-
Place as Subject:
-
CIO:
-
Division:
-
Topic:
-
Location:
-
Pages in Document:1-13
-
Contributor:Goldfeder, William
-
NIOSHTIC Number:20037536
-
NTIS Accession Number:PB2010-115407
-
Citation:Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE F2010-07, 2010 Aug; :1-13
-
Federal Fiscal Year:2010
-
NORA Priority Area:
-
Peer Reviewed:False
-
NAICS and SIC Codes:
-
Start Date:2010/02/10
-
Resource Number:FACE-F2010-07
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: