Career Lieutenant Killed in Building Collapse While Fighting Row House Fire – Pennsylvania

Supporting Files Public Domain
File Language:
English


Select the Download button to view the document
Please click the download button to view the document.

Details

  • Personal Author:
  • Corporate Authors:
  • Description:
    Death in the Line of Duty…a Report from the NIOSH Fire Fighter Fatality Investigation and Prevention Program

    On January 6, 2018, a 42-year-old career Lieutenant (Engine-45 officer) was killed in a structural collapse while fighting a fire in an 1800's era row house. Firefighters arrived to find a two-story row house heavily involved in fire. Fire crews faced limited street access to the fire dwelling (snow covered narrow road and civilian parking), excessive clutter in the building, extreme cold, multiple inoperable fire hydrants and a frozen handline (nozzle). The first arriving crews operating only off tank water were able to locate and remove a civilian victim from the first floor and initially knock down the fire on the first floor. Interruptions in water supply hampered fire-fighting efforts and forced a change in strategy until a reliable supply was established. Once the water supply was re-established, crews re-entered the structure to continue to extinguish the fire. Fire crews reported excessive debris scattered throughout the interior. Engine-45's officer and his tip man re-entered the structure after changing out their SCBA cylinders and joined several other members on the first floor including, Rescue-1's Search Firefighter, Squad-72's officer and Engine-50's Pak. There was a total of 5 firefighters on the first floor with 2 additional firefighters (Squad-72 Tip and Squad-72 Pak) in the vestibule area at the front door. Another crew of 3 firefighters from different companies stretched a line in and up the interior stairs on the Bravo wall to the second floor. One firefighter from this crew advanced onto the second floor, while the two other members remained on the stairs to advance hoseline. The firefighter on the second floor experienced a shift in the floor and without time to react, the second floor collapsed into the first floor. Squad-72's officer reported hearing a loud crack and went to the front door (side Alpha) and told Command to get everyone out. Some members operating on the first floor were pushed forward (towards side Alpha interior) during the collapse except for the Engine-45 officer. Members of the crew on the second floor either rode the floor down and escaped out of side Charlie or escaped out of the side Alpha entry door. The victim was pinned down by the second-floor joists and was unable to escape. Rescue crews worked continuously for approximately 60 minutes in extremely dangerous conditions to extricate the lieutenant. He died of positional asphyxia with superheated gas and smoke inhalation. Key Recommendations: 1) Fire Departments should consider increasing response capabilities during extreme weather. 2) Fire Departments should consider defensive operations when a dependable, continuous water supply is lost or not available and the building's primary building materials may have been subject to severe fire conditions. 3) Fire Departments should ensure that firefighters are trained to understand the influence of building age, use, design, modifications and construction on structural collapse, and consider defensive operations when hoarding/dilapidated conditions are evident or encountered. 4) Fire Departments should perform a thorough risk assessment, including an evaluation of structural conditions, when switching from a defensive strategy back to an offensive strategy. Additionally, governing municipalities (federal, state, regional, and local) should: Consider upgrading access to narrow roadways in 19th century neighborhoods or restrict parking so access is maintained for modern fire apparatus.

  • Subjects:
  • Keywords:
  • FACE - Firefighter:
  • Series:
  • Subseries:
  • DOI:
  • Publisher:
  • Document Type:
  • Genre:
  • Place as Subject:
  • CIO:
  • Division:
  • Topic:
  • Location:
  • Pages in Document:
    1-150
  • Contributor:
    DeVallance, David B. ; Stutzman, Paul ; Naum, Christopher J.
  • NIOSHTIC Number:
    nn:20060469
  • NTIS Accession Number:
    PB2021-100172
  • Citation:
    Morgantown, WV: U.S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, FACE F2018-03, 2020 Jul ; :1-150
  • Federal Fiscal Year:
    2020
  • NORA Priority Area:
  • Peer Reviewed:
    False
  • NAICS and SIC Codes:
  • Start Date:
    2018/01/06
  • Collection(s):
  • Main Document Checksum:
    urn:sha-512:b26a4dc5d0c57662d6466a12797b469e93d18f5f45a6b75430d4307d74a6cf8b13fbbb97c974046d31cb7f1de520eb6b960805fb4d9c9b69d13cb0cb2e06fb39
  • Download URL:
  • File Type:
    Filetype[PDF - 10.54 MB ]
File Language:
English
ON THIS PAGE

CDC STACKS serves as an archival repository of CDC-published products including scientific findings, journal articles, guidelines, recommendations, or other public health information authored or co-authored by CDC or funded partners.

As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.