Evaluating Reception Center Models for Radiation Response Screening Capacity and Throughput Predictions



Public Access Version Available on: August 01, 2025, 12:00 AM
Please check back on the date listed above.
English

Details:

  • Alternative Title:
    Health Phys
  • Personal Author:
  • Description:
    Introduction:

    The current fleet of nuclear reactors in the United States is mandated to provide evidence that surrounding jurisdictions can screen their populations should an incident occur. Capacity can be measured as throughput in reception centers used for screening. Due to the significant staffing and resources required to exercise screening capacity, most jurisdictions typically perform smaller exercises and use models to estimate their overall throughput.

    Objective:

    To evaluate the applicability and realism of current throughput models and practices.

    Methods:

    Throughput capacity for radiation screening is estimated with a mathematical model derived by the Federal Emergency Management Agency (FEMA). The Centers for Disease Control and Prevention developed a discrete event simulation model as a tool, SimPLER, to evaluate capacity and make throughput predictions. Model estimates will be compared and evaluated using timing data collected at a large-scale exercise.

    Results:

    The FEMA model estimated a throughput 41.2% higher than the actual radiation screening throughput, while the SimPLER model provided identical values. The FEMA and SimPLER models’ predicted throughputs were 50% and 3.8%, respectively, higher than total exercise throughput. Applying each model to the throughput projections for a 12-hour shift, the FEMA model estimates ranged from 665 to 6,646 people and the SimPLER model yielded an estimated throughput of 1,809 people with a standard deviation of 74.6.

    Conclusion:

    Discrete event simulation models, such as SimPLER, may provide more realistic and accurate predictions of radiation screening and throughput capacity of reception centers than mathematical models such as the FEMA model.

  • Subjects:
  • Keywords:
  • Source:
  • Pubmed ID:
    38517299
  • Pubmed Central ID:
    PMC11321534
  • Document Type:
  • Funding:
  • Volume:
    127
  • Issue:
    2
  • Collection(s):
  • Main Document Checksum:
  • File Type:
  • Supporting Files:
    No Additional Files
More +

You May Also Like

Checkout today's featured content at stacks.cdc.gov