A Comparison of Examination Equipment Used During Common Clinical Ophthalmologic Tasks
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

A Comparison of Examination Equipment Used During Common Clinical Ophthalmologic Tasks

Filetype[PDF-497.65 KB]


  • English

  • Details:

    • Alternative Title:
      IIE Trans Occup
    • Description:
      Background:

      Ophthalmologists report a high prevalence of work-related musculoskeletal symptoms, particularly of the neck and shoulders. Improving the design of equipment used in the clinical environment may reduce exposures to physical risk factors (e.g., sustained muscular exertions and non-neutral postures) associated with neck and shoulder pain among ophthalmologists.

      Purpose:

      To compare estimates of neck and shoulder muscle activity and upper arm posture during use of conventional and alternative examination equipment common in clinical ophthalmologic practice.

      Methods:

      Fifteen ophthalmologists performed one mock clinical examination using conventional equipment and one mock clinical examination using alternative equipment with the potential to reduce exposure to sustained muscular exertions and non-neutral upper arm postures. The alternative equipment included a slit-lamp biomicroscope with inclined viewing oculars, adjustable elbow supports, and a wider table-top with more room for supporting the arms in comparison to the conventional slit-lamp biomicroscope. A wireless binocular indirect ophthalmoscope was also evaluated that had a more even weight distribution than the conventional design. Measurements of upper trapezius and anterior deltoid muscle activity, upper arm posture, and perceived usability were used to compare the conventional and alternative equipment.

      Results:

      In comparison to the conventional slit lamp biomicroscope, the alternative slit lamp biomicroscope led to (i) 12% to 13% reductions in upper trapezius muscle activity levels, (ii) a 9% reduction in left anterior deltoid muscle activity levels, and (iii) a 15% reduction in the percentage of work time spent with the left upper arm elevated in positions greater than 60°. In addition, participants rated the comfort and adjustability of both the alternative slit lamp biomicroscope and binocular indirect ophthalmoscope more favorably than the conventional equipment.

      Conclusions:

      The results suggest that the alternative slit-lamp biomicroscope may help to reduce overall muscular demands and non-neutral postures of the neck and shoulder region among ophthalmologists.

    • Pubmed ID:
      37180554