Critical investigation of glove–gown interface barrier performance in simulated surgical settings
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Critical investigation of glove–gown interface barrier performance in simulated surgical settings

Filetype[PDF-1.08 MB]


  • English

  • Details:

    • Alternative Title:
      J Occup Environ Hyg
    • Description:
      The barrier properties of personal protective equipment are vital to healthcare personnel to protect themselves from possible infectious body fluids. Intraoperative exposure of healthcare personnel to body fluids can be substantial in both inpatient and outpatient settings. The glove-gown interface is known as one of the weakest points of the whole personal protective equipment system. However, there is a lack of scientific research designed to investigate the problem. This paper reports the results of experiments using a new testing methodology developed to quantify fluid leakage through the glove-gown interface while simulating surgical settings in terms of operating room personnel activities, exposure types, exposure durations, and physical stresses applied on the interface. This study represents one of the first efforts investigating the amount of fluid leakage through the glove-gown interface for a number of surgical gown and glove models while considering glove material differences and single | double gloving. The test results showed that there is a significant difference in fluid leakage amounts between three gown models and four glove models studied. The results also demonstrated that double gloving significantly reduced the fluid leakage compared to single glove use. The mean fluid leakage was lower in the double synthetic glove configurations (M = 2.76g) compared with all other configurations (3GLV, M = 8.3g; 4GLV, M = 9.49g; 5GLV, M = 3.08g; 6GLV, M = 20.03g; double latex, M = 5.22g). Findings highlighted a significant interaction between glove and gown designs, which suggests that gown and gloves should be designed together as a system to minimize or eliminate the fluid leakage.
    • Pubmed ID:
      31021715
    • Pubmed Central ID:
      PMC10009782
    • Document Type:
    • Collection(s):
    • Main Document Checksum:
    • File Type:

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov