Relationships between annulus thickness and the integrity of resin-grouted roof bolts
Details:
-
Personal Author:
-
Corporate Authors:
-
Description:"If resin-grouted roof bolts are not installed correctly, mine roof reinforcement can be affected, and roof falls can result. A bolt installation variable that is readily controlled by the mine operator is annulus thickness. The ojective of this U.S. Bureau of Mines investigation was to study the effect of annulus thickness variations on the integrity of 3/4-in-diam resin-grouted bolts. Forged-head test bolts, 2 and 1 ft long, were installed in concrete blocks that had been drilled with 1-, 1-1/8-, 1-1/4-, 1-3/8-, and 1- 1/2-in-diam bits. Standard pull tests were performed; then the concrete was broken away from the bolts so that grout mix quality could be inspected. It was found that the optimum annulus thickness is 1/8 in (1-in-diam drill hole), and as annulus thickness increases from the optimum, there is a corresponding decrease in grout mix quality, effective grout ratio, and axial stiffness." - NIOSHTIC-2
NIOSHTIC no. 10007257
-