i
Superseded
This Document Has Been Replaced By:
i
Retired
This Document Has Been Retired
i
Up-to-date Information
This is the latest update:
Design of a water curtain to reduce accumulations of float coal dust in longwall returns
-
Published Date:
Jul 2020
-
Source:Int J Min Sci Technol. 30(4):443-447
-
Language:English
-
Details:
-
Alternative Title:Int J Min Sci Technol
-
Personal Author:
-
Description:Accumulation of float coal dust (FCD) in underground mines is an explosion hazard that affects all underground coal mine workers. While this hazard is addressed by the application of rock dust, inadequate rock dusting practices can leave miners exposed to an explosion risk. Researchers at the National Institute for Occupational Safety and Health (NIOSH) have focused on developing a water curtain that removes FCD from the airstream, thereby reducing the buildup of FCD in mine airways. In this study, the number and spacing of the active sprays in the water curtain were varied to determine the optimal configuration to obtain peak knockdown efficiency (KE) while minimizing water consumption.
-
Subject:
-
Pubmed ID:32953195
-
Pubmed Central ID:PMC7500871
-
Document Type:
-
Collection(s):
-
Main Document Checksum:
- File Type:
-
Supporting Files:
image/gif image/jpeg text/xml image/gif image/jpeg image/gif image/jpeg image/gif image/jpeg image/gif image/jpeg
No Related Documents.