Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Evaluation of a sheathed permissible explosive charge for open shooting in flammable atmospheres

Filetype[PDF-1.06 MB]


  • English

  • Details:

    • Description:
      The Bureau of Mines has developed a prototype nonincendive explosive rock-breaker charge that can be fired unconfined in underground bituminous coal mines without the danger of igniting a flammable atmosphere that might be present. At present, unconfined shooting in underground coal mines is prohibited, but there are situations where the use of such shots would yield an overall improvement in safety. The charge consists of 1-1/2 lb of permissible water gel explosive in the form of a short cylinder 7 inches in diameter and 7/8 inches high, surrounded by a 1/2-inch-thick layer of damp salt, and encased in latex rubber reinforced with cheese cloth. The latex rubber housing provides a charge package that is strong enough to resist rough handling yet is pliable enough to conform to an irregular stone surface. A charge of this shape was found to be more effective at breaking rock than charges with lined or unlined cavities. Incendivity tests in a gallery have shown that the prototype charge will not ignite a flammable methane-air atmosphere when fired. Rockbreaking tests made with limestone boulders indicate that the charge will satisfactorily break stone slabs weighing 1 to 2 tons, and that two or more charges might be effective for slabs weighing up to 10 tons. In cooperation with the Mine Safety and Health Administration (MSHA), a test protocol for the certification of these charges as "permissible" for use in flammable atmospheres is being developed.
    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov