Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Overview Of Mine Fire Detection

  • 1998

  • Source: Proceedings from the Second International Conference on Fire Research and Engineering. Bethesda, MD: Society of Fire Protection Engineers, 1998 Aug; :489-499
Filetype[PDF-567.00 KB]


  • English

  • Details:

    • Personal Author:
    • Description:
      Several experimental programs were conducted at the Pittsburgh Research Center to investigate the level of mine fire detection and alarm capability possible using state-of-the-art technology. These programs involved comparison of the response and alarm time of optical and ionization type smoke sensors to smoldering and flaming coal combustion in a smoke chamber. Coal combustion experiments conducted in the smoke chamber demonstrated that a CO concentration of 5 ppm above ambient corresponded to an optical density of 0.022m1. For the four smoke sensors for which a continuous analog signal was available, a smoke sensor alarm was defined as the average background signal plus ten times the peak-to-peak noise. This alarm criterion resulted in the association of the alarm for three of the four sensors with a smoke optical density of 0.022m-1. and 0.033m-1 for the fourth smoke sensor. The smoke sensors used in the smoke chamber studies were incorporated into large scale diesel fuel fire experiments conducted under normal ventilation conditions in the Safety Research Coal Mine (SRCM) at the Pittsburgh Research Center. These experiments showed that a diffusion mode smoke sensor alarmed earlier than a diffusion mode CO sensor; and, based upon the measurement of the optical transmission at the location of a pump mode ionization type smoke sensor that a pump mode ionization smoke sensor alarmed at an average smoke optical density of 0.021m" for the twelve experiments conducted. A series of 30 and 330 kW diesel fuel fire intensity experiments were conducted under zero airflow conditions in the SRCM. It was determined that :(I) thermal sensors are inadequate at 30 m from a 300 kW fire;(2) a diffusion mode ionization smoke sensor can be more effective for mine fire detection than a diffusion mode CO sensor;(3) recommendations can be made for sensor spacing in a mine entry based upon the measured CO buoyancy induced spread rates along the mine roof and the time for a developing coal fire to ignite a conveyor belt.
    • Subjects:
    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov