<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">7709027</journal-id><journal-id journal-id-type="pubmed-jr-id">7774</journal-id><journal-id journal-id-type="nlm-ta">Toxicol Lett</journal-id><journal-id journal-id-type="iso-abbrev">Toxicol. Lett.</journal-id><journal-title-group><journal-title>Toxicology letters</journal-title></journal-title-group><issn pub-type="ppub">0378-4274</issn><issn pub-type="epub">1879-3169</issn></journal-meta><article-meta><article-id pub-id-type="pmid">31812604</article-id><article-id pub-id-type="pmc">7187403</article-id><article-id pub-id-type="doi">10.1016/j.toxlet.2019.12.007</article-id><article-id pub-id-type="manuscript">HHSPA1581139</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Application of the Fentanyl Analog Screening Kit toward the Identification of Emerging Synthetic Opioids in Human Plasma and Urine by LC-QTOF</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Krajewski</surname><given-names>Logan C.</given-names></name><xref ref-type="aff" rid="A1">1</xref></contrib><contrib contrib-type="author"><name><surname>Swanson</surname><given-names>Kenneth D.</given-names></name><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Bragg</surname><given-names>William A</given-names></name><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Shaner</surname><given-names>Rebecca L.</given-names></name><xref ref-type="aff" rid="A2">2</xref><xref rid="CR1" ref-type="corresp">*</xref></contrib><contrib contrib-type="author"><name><surname>Seymour</surname><given-names>Craig</given-names></name><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Carter</surname><given-names>Melissa D.</given-names></name><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Hamelin</surname><given-names>Elizabeth I.</given-names></name><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Johnson</surname><given-names>Rudolph C.</given-names></name><xref ref-type="aff" rid="A2">2</xref></contrib></contrib-group><aff id="A1"><label>1.</label>Battelle Memorial Institute at the Centers for Disease Control and Prevention, Atlanta, GA 30341</aff><aff id="A2"><label>2.</label>Division of Laboratory Sciences, National Center for Environmental Health, CDC, Atlanta, GA 30341</aff><author-notes><corresp id="CR1"><label>*</label>Correspondence to: R. L. Shaner, Division of Laboratory Sciences, Centers for Disease Control and Prevention, 4770 Buford Hwy NE, MS-F44, Atlanta, GA 30341, USA. <email>rebecca.shaner@cdc.hhs.gov</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>3</day><month>4</month><year>2020</year></pub-date><pub-date pub-type="epub"><day>05</day><month>12</month><year>2019</year></pub-date><pub-date pub-type="ppub"><day>01</day><month>3</month><year>2020</year></pub-date><pub-date pub-type="pmc-release"><day>01</day><month>3</month><year>2021</year></pub-date><volume>320</volume><fpage>87</fpage><lpage>94</lpage><!--elocation-id from pubmed: 10.1016/j.toxlet.2019.12.007--><abstract id="ABS1"><p id="P1">Human exposures to fentanyl analogs, which significantly contribute to the ongoing U.S. opioid overdose epidemic, can be confirmed through the analysis of clinical samples. Our laboratory has developed and evaluated a qualitative approach coupling liquid chromatography and quadrupole time-of-flight mass spectrometry (LC-QTOF) to address novel fentanyl analogs and related compounds using untargeted, data-dependent acquisition. Compound identification was accomplished by searching against a locally-established mass spectral library of 174 fentanyl analogs and metabolites. Currently, our library can identify 150 fentanyl-related compounds from the Fentanyl Analog Screening (FAS) Kit), plus an additional 25 fentanyl-related compounds from individual purchases. Plasma and urine samples fortified with fentanyl-related compounds were assessed to confirm the capabilities and intended use of this LC-QTOF method. For fentanyl, 8 fentanyl-related compounds and naloxone, lower reportable limits (LRL<sub>100</sub>), defined as the lowest concentration with 100% true positive rate (n=12) within clinical samples, were evaluated and range from 0.5 ng/mL to 5.0 ng/mL for urine and 0.25 ng/mL to 2.5 ng/mL in plasma. The application of this high resolution mass spectrometry (HRMS) method enables the real-time detection of known and emerging synthetic opioids present in clinical samples.</p></abstract><abstract id="ABS2" abstract-type="graphical"><title>Graphical Abstract</title><p id="P47"><graphic xlink:href="nihms-1581139-f0001.jpg" position="anchor" orientation="portrait"/></p></abstract></article-meta></front><body><sec id="S1"><label>1.</label><title>Introduction</title><p id="P2">Drug overdose deaths in the United States have risen substantially with deaths involving opioids contributing significantly to the drug overdose epidemic (<xref rid="R24" ref-type="bibr">Scholl et al., 2019</xref>). Much of this is due to synthetic opioids such as fentanyl and fentanyl analogs, with a 45.2% increase in death rates related to these compounds from 2016 to 2017 (<xref rid="R24" ref-type="bibr">Scholl et al., 2019</xref>). A similar trend has also been seen in Europe (<xref rid="R2" ref-type="bibr">UNODC, 2017</xref>; <xref rid="R17" ref-type="bibr">Mounteney et al., 2015</xref>). While fentanyl was synthesized in the 1960&#x02019;s by Jansson pharmaceuticals, modifications to increase potency or onset has added multiple analogs to this family of compounds (<xref rid="R33" ref-type="bibr">Vardanyan and Hruby, 2014</xref>). In 2018, 8 out of the 26 synthetic opioids identified in the US were reported for the first time (<xref rid="R8" ref-type="bibr">DEA, 2018</xref>). With this rapid addition of new analogs, methods to identify exposure to as many fentanyl analogs as possible are needed.</p><p id="P3">Developed methods to detect fentanyl, fentanyl analogs, and metabolites in biological matrices include immunoassays (<xref rid="R3" ref-type="bibr">Angelini et al., 2019</xref>; <xref rid="R11" ref-type="bibr">Guerrieri et al., 2019</xref>; <xref rid="R22" ref-type="bibr">Ruangyuttikam et al., 1990</xref>; <xref rid="R25" ref-type="bibr">Schuttler and White, 1984</xref>; <xref rid="R34" ref-type="bibr">Wang et al., 2011</xref>), gas chromatography mass spectrometry (GC-MS) (<xref rid="R4" ref-type="bibr">Buchalter et al., 2019</xref>; <xref rid="R10" ref-type="bibr">Gillespie et al., 1981</xref>; <xref rid="R14" ref-type="bibr">Misailidi et al., 2019</xref>; <xref rid="R32" ref-type="bibr">Van Rooy, 1981</xref>), and liquid chromatography tandem mass spectrometry (LC-MS/MS) (<xref rid="R9" ref-type="bibr">Fogarty et al., 2018</xref>; <xref rid="R27" ref-type="bibr">Seymour et al., 2019</xref>; <xref rid="R29" ref-type="bibr">Sofalvi et al., 2017</xref>; <xref rid="R30" ref-type="bibr">Strayer et al., 2018</xref>). While immunoassays are typically quick and sensitive, many are neither able to identify nor distinguish between emerging fentanyl analogs since the selectivity of the antibodies used was developed primarily for the detection of fentanyl (<xref rid="R11" ref-type="bibr">Guerrieri et al., 2019</xref>). When responses are detected, cross-reactivity of the antibodies may make it impossible to differentiate analogs (<xref rid="R11" ref-type="bibr">Guerrieri et al., 2019</xref>). Methods using GC-MS and LC-MS/MS have been developed for many fentanyl analogs in human matrices including urine, blood, plasma, and oral fluid (<xref rid="R4" ref-type="bibr">Buchalter et al., 2019</xref>; <xref rid="R5" ref-type="bibr">Busardo et al., 2019</xref>; <xref rid="R9" ref-type="bibr">Fogarty et al., 2018</xref>; <xref rid="R14" ref-type="bibr">Misailidi et al., 2019</xref>; <xref rid="R19" ref-type="bibr">Palamar et al., 2019</xref>; <xref rid="R23" ref-type="bibr">Salomone et al., 2019</xref>; <xref rid="R27" ref-type="bibr">Seymour et al., 2019</xref>; <xref rid="R29" ref-type="bibr">Sofalvi et al., 2017</xref>; <xref rid="R30" ref-type="bibr">Strayer et al., 2018</xref>). These methods were reported to have detection limits as low as 0.002 ng/mL for selected compounds, with most fentanyl analog detection limits around 0.1 ng/mL (<xref rid="R5" ref-type="bibr">Busardo et al., 2019</xref>; <xref rid="R9" ref-type="bibr">Fogarty et al., 2018</xref>; <xref rid="R14" ref-type="bibr">Misailidi et al., 2019</xref>; <xref rid="R23" ref-type="bibr">Salomone et al., 2019</xref>; <xref rid="R27" ref-type="bibr">Seymour et al., 2019</xref>; <xref rid="R29" ref-type="bibr">Sofalvi et al., 2017</xref>; <xref rid="R30" ref-type="bibr">Strayer et al., 2018</xref>). When applied to case reports of opioid overdoses, carfentanil, acetylfentanyl, acrylfentanyl, and furanyl fentanyl were detected at 0.0102 ng/mL to 827 ng/mL (<xref rid="R6" ref-type="bibr">Butler et al., 2018</xref>; <xref rid="R13" ref-type="bibr">Martucci et al., 2018</xref>; <xref rid="R15" ref-type="bibr">Mochizuki et al., 2018</xref>; <xref rid="R28" ref-type="bibr">Shanks and Behonick, 2017</xref>; <xref rid="R29" ref-type="bibr">Sofalvi et al., 2017</xref>; <xref rid="R31" ref-type="bibr">Swanson et al., 2017</xref>). The lowest concentration was attributed to carfentanil, which has also been determined to be significantly more toxic than most other analogs (<xref rid="R28" ref-type="bibr">Shanks and Behonick, 2017</xref>). The majority of these case studies identified in overdose samples were detected at 0.1 ng/mL or greater.</p><p id="P4">While targeted GC-MS and LC-MS/MS methods allow for low detection levels, they are limited to the analytes predetermined in each method. Recent targeted methods, developed in response to the opioid crisis, have typically reported around 20 fentanyl analogs per method (<xref rid="R5" ref-type="bibr">Busardo et al., 2019</xref>; <xref rid="R9" ref-type="bibr">Fogarty et al., 2018</xref>; <xref rid="R30" ref-type="bibr">Strayer et al., 2018</xref>). To identify a broader array of compounds, an untargeted approach for data collection is needed. High resolution mass spectrometry has been used as a data-independent technique for detection of multiple fentanyl analogs in clinical and forensic samples (<xref rid="R18" ref-type="bibr">Noble et al., 2018</xref>; <xref rid="R20" ref-type="bibr">Palmquist and Swortwood, 2019</xref>). Following data acquisition, the collected data are evaluated against a reference spectral library for accurate mass and fragmentation patterns to identify and confirm the compounds present. As new reference materials for emerging opioids becomes available their reference spectra can be added to the library. Since compounds are identified after data collection, the results can potentially be retrospectively and independently interrogated evaluated for these new compounds (<xref rid="R7" ref-type="bibr">Campos-Ma&#x000f1;as et al., 2019</xref>; <xref rid="R18" ref-type="bibr">Noble et al., 2018</xref>; <xref rid="R21" ref-type="bibr">Partridge et al., 2018</xref>).</p><p id="P5">Mass spectral libraries can be purchased or created in-house. Currently commercially available forensic libraries offered by three major instrument vendors contain up to 18 fentanyl analogs. Published libraries include up to 50 fentanyl analogs; however, some of those identifications are based on predicted product ions, not the infusion of reference materials (<xref rid="R18" ref-type="bibr">Noble et al., 2018</xref>). Our method utilizes the newly available product line of Traceable Opioid Material<sup>&#x000a7;</sup> Kits (TOM Kits<sup>&#x000a7;</sup>), specifically the Fentanyl Analog Screening (FAS) Kit, along with 25 other commercially available and custom synthesized compounds to create an in-house spectral library of 174 synthetic opioid compounds. Using Scientific Working Group for Forensic Toxicology (SWGTOX) guidelines, a qualitative method was developed and fully validated for a subset of 10 synthetic opioid compounds; including investigating the lower reportable limit, matrix effects, and possible interferences; in both urine and plasma (<xref rid="R26" ref-type="bibr">Scientific Working Group for Forensic, 2013</xref>). This method has been designed to collect data permitting the identification of currently known fentanyl-related compounds and retrospective data mining as new fentanyl analogs are discovered.</p></sec><sec id="S2"><label>2.</label><title>Materials and Methods</title><sec id="S3"><label>2.1</label><title>Materials.</title><p id="P6">High-pressure liquid chromatography (HPLC) grade methanol (Fisher, Hampton, NH), acetonitrile (The Lab Depot, Dawsonville, GA), and dichloromethane (DCM) (The Lab Depot, Dawsonville, GA) were used for all experiments. Deionized (DI) water was prepared with an on-site water purification system (Aqua Solutions Inc., Jasper, GA). Ammonium formate and formic acid (99%) were acquired from Sigma Aldrich (Pittsburg, PA). Isotopically labeled (<sup>2</sup>H<sub>5</sub>) standards of cyclopropylfentanyl, 2-furanylfentanyl, acrylfentanyl, isobutyrylfentanyl, ocfentanil, and methoxyacetylfentanyl were purchased from Cayman Chemical (Ann Arbor, MI). Fentanyl, norfentanyl, and corresponding <sup>2</sup>H<sub>5</sub> labeled standards as well as acetylfentanyl and corresponding <sup>13</sup>C<sub>6</sub> labeled standard were purchased from Cerilliant (Round Rock, TX). Naloxone, naltrexone, heroin, 6-MAM, morphine, morphine-6-G, cocaine, and norcocaine were also purchased from Cerilliant. Norlofentanil and corresponding <sup>2</sup>H<sub>3</sub> labeled standard were purchased from Toronto Research Chemicals (Toronto, Canada). Carfentanil, norcarfentanil, sufentanil, norsufentanil, corresponding <sup>2</sup>H<sub>5</sub> labeled standards, and <sup>13</sup>C<sub>6</sub>-alfentanil were custom synthesized by Battelle (Columbus, OH). Pooled urine and pooled plasma along with individual urine and plasma reference samples were purchased from Tennessee Blood Services (Memphis, TN). This study does not meet the definition of human subjects as specified in 45 CFR 46.102 (f) as all urine and plasma samples were acquired from commercial sources with appropriate institutional review board approvals.</p></sec><sec id="S4"><label>2.2</label><title>Evaluation Samples.</title><p id="P7">Three novel opioids and benzodiazapines (NOB) survey samples from the College of American Pathologists (CAP) were used to challenge our method. The samples, prepared by CAP in processed ovine blood, were evaluated in the same manner as human plasma samples used for method development.</p></sec><sec id="S5"><label>2.3</label><title>Fentanyl Analog Screening (FAS) Kit.</title><p id="P8">CDC has contracted Cayman Chemical (Ann Arbor, MI) to manufacture and distribute the FAS Kit containing 200 micrograms each of 120 fentanyl analogs and metabolites analytical reference materials (<xref rid="R1" ref-type="bibr">Fentanyl Analog Screening Kit, FAS Kit</xref>). In addition, an expansion pack (Emergent Panel Version 1, FAS V1) was developed to contain 200 micrograms of an additional 30 synthetic opioid related compounds. Each compound in the FAS Kit and FAS V1 was provided in separate, individual vials. A list of all synthetic opioids and related compounds in the FAS Kit and FAS V1 can be found on the vendor&#x02019;s website (<ext-link ext-link-type="uri" xlink:href="https://www.caymanchem.com/forensics/faskit/">https://www.caymanchem.com/forensics/faskit/</ext-link>). FAS kit development is explored in greater depth by Mojica et al. (<xref rid="R16" ref-type="bibr">Mojica et al, 2019</xref>)</p></sec><sec id="S6"><label>2.4</label><title>Working Solutions</title><p id="P9">Individual stock solutions of all analytes, purchased individually or provided in the FAS Kit and FAS V1, were prepared at 10 &#x003bc;g/mL in a mixture of methanol and DI water at a ratio of 3:2, respectively, with individual working solutions generated by diluting to 100 ng/mL in DI water. A 25 ng/mL internal standard (IS) working solution was created by a mixture of the isotopically labeled standards of fentanyl, carfentanil, acetylfentanyl, 2-furanylfentanyl, cyclopropylfentanyl, acrylfentanyl, sufentanil, ocfentanil, and methoxyacetylfentanyl. To form a 1 &#x003bc;g/mL quality control (QC) stock solution, 4-ANPP, acetylfentanyl, carfentanil, cyclopropylfentanyl, fentanyl, fluoroisobutyrylfentanyl, furanylfentanyl, methoxyacetylfentanyl, naloxone, and norfentanyl were diluted from the 10 &#x003bc;g/mL stock solutions. The QC stock solution was further diluted in pooled urine and plasma to create a positive QC Low (QCL) at 2 ng/mL and a positive QC High (QCH) at 15 ng/mL. In addition, an aliquot of pooled urine and plasma with no fortification was designated as a negative QC Blank (QCB).</p></sec><sec id="S7"><label>2.5</label><title>Sample Preparation.</title><p id="P10">A 200 &#x003bc;L aliquot of urine or plasma sample was pipetted into a 2 mL conical bottomed 96-deep well plate. IS working solution (25 &#x003bc;L) was added to the 96-deep well plate, followed by 175 &#x003bc;L of 0.1% v/v formic acid in DI water. The 96-deep well plate was sealed with adhesive foil and mixed at 1,000 rpm for 5 minutes (Eppendorf MixMate, Hauppauge, NY). The extraction was automated using a Biotage Extrahera (Charlotte, NC). The diluted sample was pipetted onto a Biotage ISOLUTE SLE+ 400 &#x003bc;L plate and given a 5 second burst of positive pressure air. The sample was allowed to absorb onto the media for 5 minutes, after which time 900 &#x003bc;L of DCM was applied to each sample well in the SLE plate. The DCM eluted without added pressure for 5 minutes into an empty 96-deep well plate. After 5 minutes, 0.7 bar of positive pressure was applied to the SLE plate to ensure the entire aliquot of DCM had eluted before a second 900 &#x003bc;L aliquot of DCM was added again to each sample well in the SLE plate. After 5 minutes had elapsed after the addition of the second 900 &#x003bc;L aliquot, a final 5 second burst of positive pressure was applied to the SLE plate. The collection plate was removed from the Extrahera and dried down with N<sub>2</sub> using a Porvair TurboVap (Ashland, VA) at a maximum temperature of 55 &#x000b0;C until dryness. The dried samples were then reconstituted in 100 &#x003bc;L of 78:22 10 mM ammonium formate in water : 0.1% v/v formic acid in acetonitrile. The 96-deep well plate was sealed with adhesive foil and shaken at 1,000 rpm for 5 minutes. The samples were then transferred into a 96-well PCR plate, heat sealed, and loaded into the instrument for analysis.</p></sec><sec id="S8"><label>2.6</label><title>Liquid Chromatography.</title><p id="P11">An Agilent Technologies 1290 Infinity II Liquid Chromatography (LC) system (Santa Clara, CA) with a 100 &#x000d7; 3.0 mm Phenomenex (Torrance, CA) biphenyl column kept at 50 &#x000b0;C was used for chromatographic separation. The column has a particle size of 2.6 &#x003bc;m and a pore size of 100 &#x000c5;. For separation the eluents (A) 10 mM ammonium formate in DI water and (B) acetonitrile containing 0.1% v/v formic acid were used in the following gradient with a 700 &#x003bc;L/min flow rate: 78% A held for 0.5 min then reduced to 75% A over next 8.5 min. After 9 min A reduced to 70% over 2 min, then dropped to 60% at 11.01 min. From 11.01 min A was reduced to 55% over 1.99 min, and at 13 min A reduced to 5% over 0.60 min, at which it was held until chromatography completion at 16 min. The sample (15 &#x003bc;L) was injected, and the needle multi-washed with methanol containing 1% v/v formic acid and 82:18 10 mM ammonium formate in DI water : 0.1% v/v formic acid in acetonitrile before each injection.</p></sec><sec id="S9"><label>2.7</label><title>Mass Spectrometry.</title><p id="P12">Mass analysis was performed with an Agilent 6545 Q-TOF mass spectrometer in Auto MS/MS mode controlled using Agilent&#x02019;s MassHunter Data Acquisition Version B.09.00. Analytes were ionized in positive mode electrospray ionization (ESI) using an Agilent Jet Stream source. The first 0.5 minutes and last 2 minutes of the chromatographic separation were diverted to waste. A capillary voltage of 3500 V and nozzle voltage of 1000 V was used for ESI, along with nebulizer and sheath gas (ultra-high purity nitrogen) at 350 &#x000b0;C to assist in ionization. For broadband MS analysis a mass range of <italic>m/z</italic> 100&#x02013;1000 was analyzed a rate of 5 spectra/s and a time of 200 ms/spectrum. For each MS cycle, two precursors within <italic>m/z</italic> 200&#x02013;600 and with at least 1000 counts abundance were automatically selected for MS/MS. Those precursors were then dynamically excluded for 0.1 minutes. To conserve cycle time, all IS compounds were placed on a static exclusion list, except fentanyl-D<sub>5</sub> which was used as a control to ensure sample viability. To ensure identification of library components, a list of the compounds in the library was used for preferential precursor selection. Precursors were isolated with a medium isolation width (~4 Da wide) and fragmented by collision-induced dissociation (CID) at 20 eV and 40 eV. The fragments were acquired at a rate of 3 spectra/s and a time of 333.3 ms/spectrum across <italic>m/</italic>z 50&#x02013;1000. The instrument was externally calibrated daily with Agilent low concentration ESI tuning mix, and each analysis internally calibrated with purine and HP-0921 (hexakis(1H, 1H, 3H-tetrafluoropropoxy)phosphazine) from Agilent&#x02019;s ESI-TOF reference mass solution kit.</p></sec><sec id="S10"><label>2.8</label><title>Creation of a Spectral Library using the FAS Kit and FAS V1</title><p id="P13">The molecular formula of the synthetic opioids, fentanyl analogs, or other associated compounds found in the FAS Kit, FAS V1, or available in-house were entered into a personal compound database and library (PCDL) along with their calculated monoisotopic mass using MassHunter PCDL Manager B.08.00 (Agilent). To acquire mass fragmentation spectra, each individual compound stock solution was diluted to 25 ng/mL in DI water and analyzed in triplicate. The retention time (RT) was averaged and added to the PCDL alongside the fragmentation spectra. A table of all compounds in the in-house PCDL can be found in supplemental information (<xref rid="SD1" ref-type="supplementary-material">Table S1</xref>).</p></sec><sec id="S11"><label>2.9</label><title>Spectral Library Matching.</title><p id="P14">Chromatographic peaks were extracted in MassHunter Qualitative Analysis Workflows (Agilent, MassHunter Qualitative Analysis software version B.10) and identified by accurate mass and isotopic spacing using the Find-by-Formula algorithm against the in-house PCDL with a mass tolerance of &#x000b1;5 ppm and RT tolerance of &#x000b1;0.50 minutes. Only chromatographic peaks with a height greater than 7000 counts were extracted. Find by Formula&#x02019;s match score is weighted based on mass (32.3%), isotope abundance (19.4%), isotopic spacing (16.1%), and RT accuracy (32.2%). The MS/MS spectra of the precursors identified by the Find by Formula were then used for library matching against the in-house PCDL, containing the reference CID spectra at 20 and 40 eV, using the &#x0201c;Identify Compounds&#x0201d; tool in Qualitative Analysis Workflows with an allowable mass error of &#x000b1;10 ppm.</p></sec><sec id="S12"><label>2.10</label><title>Method Validation.</title><p id="P15">This method was validated for both urine and plasma following SWGTOX guidelines, as described in the following paragraphs (<xref rid="R26" ref-type="bibr">Scientific Working Group for Forensic, 2013</xref>).</p><sec id="S13"><label>2.10.1</label><title>Lower Reportable Limit.</title><p id="P16">The lower reportable limit (LRL<sub>100</sub>) for urine and plasma was determined for the quality control compounds (<xref rid="T1" ref-type="table">Table 1</xref>) by spiking one blank pooled and three blank individual matrix (urine and plasma) samples with analytes at decreasing concentration levels (5 ng/mL to 0.075 ng/mL). Analysis was performed in triplicate each day across four days. The lowest concentration level in which the compound was positively identified across all 12 replicates was reported as the LRL<sub>100</sub> for that matrix.</p></sec><sec id="S14"><label>2.10.2</label><title>Carryover.</title><p id="P17">Carryover was evaluated by injecting an extracted blank matrix immediately following injection of an extracted sample of quality control compounds at 100 ng/mL. This experiment was performed in triplicate.</p></sec><sec id="S15"><label>2.10.3</label><title>Interference.</title><p id="P18">Fifty individual urine and 50 individual plasma reference samples, assumed to be unexposed, were analyzed to confirm the absence of matrix interferences. In addition, biomarkers of several drugs of misuse commonly associated with fentanyl use (i.e., cocaine, heroin, and tramadol) were also analyzed to confirm no interference with library compounds.</p></sec><sec id="S16"><label>2.10.4</label><title>Extraction Efficiency and Matrix Effects.</title><p id="P19">Extraction efficiency was determined by comparing QC analytes spiked into matrix before and after extraction at both QC levels (2.0 and 15 ng/mL) and calculated as follows:
<disp-formula id="FD1"><mml:math display="block" id="M1"><mml:mrow><mml:mtext mathvariant="italic">Extraction&#x000a0;Efficiency</mml:mtext><mml:mo>=</mml:mo><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:mfrac><mml:mrow><mml:mtext mathvariant="italic">Area&#x000a0;of&#x000a0;pre</mml:mtext><mml:mo>&#x02212;</mml:mo><mml:mtext mathvariant="italic">extraction&#x000a0;spike</mml:mtext></mml:mrow><mml:mrow><mml:mtext mathvariant="italic">Area&#x000a0;of&#x000a0;post</mml:mtext><mml:mo>&#x02212;</mml:mo><mml:mtext mathvariant="italic">extraction&#x000a0;spike</mml:mtext></mml:mrow></mml:mfrac></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mo>&#x000d7;</mml:mo><mml:mn>100</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></disp-formula></p><p id="P20">To determine matrix effects, solutions of the QC analytes spiked post extraction in urine/plasma and QC analytes spiked at the equivalent concentration level in DI water were prepared, analyzed, and compared to each other. The DI solutions were prepared at double the QC concentration levels, as the extraction process ultimately doubles the concentration of the analyte sample concentration for analysis. Matrix effects were then calculated using SWGTOX guidelines section 7.5.2 (<xref rid="R26" ref-type="bibr">Scientific Working Group for Forensic, 2013</xref>).</p></sec><sec id="S17"><label>2.10.5</label><title>Extracted Stability.</title><p id="P21">Stability was assessed by extracting QC samples and storing at 10 &#x000b0;C for 24 hours before analysis. Samples were then evaluated to confirm all analytes were identified with the established criteria.</p></sec></sec><sec id="S18"><label>2.11</label><title>Method Characterization.</title><p id="P22">Twenty replicate analytical runs of QCL, QCH, and QCB were analyzed to evaluate internal standard abundance, retention time, and library scores. These analytical runs were extracted and analyzed by two analysts, with no more than two replicates per day, over the course of 10 separate days.</p></sec></sec><sec id="S19"><label>3.</label><title>Results and Discussion.</title><sec id="S20"><label>3.1</label><title>Method Development</title><sec id="S21"><label>3.1.1</label><title>LC parameters.</title><p id="P23">Ten synthetic opioids and related compounds were chosen and defined as QC compounds to optimize sample preparation and instrument parameters. These compounds were selected due to their frequency in recent illicit use, pharmacetical use, or association with synthetic opioid exposure or treatment (Emerging threat report). Contained within the QC compounds is one synthetic precursor (4-ANPP), one metabolite (norfentanyl), and six fentanyl analogs in addition to fentanyl. Naloxone, commonly used to treat opioid overdoses, is also included. Baseline LC separation was achieved for the compounds in the quality control solution, except two pairs of co-eluting peaks that are easily distinguished by mass. (<xref rid="F1" ref-type="fig">Figure 1</xref>). To minimize source contamination, the LC eluent was diverted to waste for the first 30 seconds and last two minutes of the analytical run.</p></sec><sec id="S22"><label>3.1.2</label><title>MS Optimization and Library Creation.</title><p id="P24">Agilent&#x02019;s Auto MS/MS parameters were optimized to capture library compounds that may be found in a sample. A preferred list, comprised of exact <italic>m/z</italic> and retention times, was established to preferentially select library compounds for fragmentation. In the event of co-eluting compounds of interest, the most abundant ion from the preferred list was selected for fragmentation. When no preferred compounds were found, the instrument selected the most abundant ion present with a height greater than 1000 counts. After two fragmentation spectra of a given <italic>m/z</italic> were acquired, at both fragmentation energies, the compound was excluded for 0.1 minutes so other compounds may be selected. The red diamonds in <xref rid="F2" ref-type="fig">Figure 2</xref> indicate where fentanyl (black peak) was selected for fragmentation. The short exclusion duration (i.e., 5.46 to 5.54 min) permits the selection of other compounds, while fragmenting fentanyl at high abundance.</p><p id="P25">All compounds from the FAS Kit, FAS V1, internal standards, additional commercially available fentanyl analogs (e.g., carfentanil), and other compounds commonly detected in fentanyl exposure specimens (e.g., naloxone and heroin metabolites) were analyzed using these parameters to create the in-house spectral library for 174 fentanyl analogs and related compounds (<xref rid="SD1" ref-type="supplementary-material">Table S1</xref>).</p></sec><sec id="S23"><label>3.1.3</label><title>Match and Confirmation Criteria.</title><p id="P26">Twenty replicate analytical runs of the QCL, QCH, and QCB were used to characterize the method and set match criteria. To minimize false positives, chromatographic peaks with a height less than 7000 counts were not evaluated. Compounds with database scores, determined by mass, isotopic abundance, isotope spacing, and RT accuracy, greater than 40 were selected for library matching. Then the experimental fragmentation pattern was compared to a reference fragmentation pattern (<xref rid="F3" ref-type="fig">Figure 3</xref>, <xref rid="F3" ref-type="fig">A</xref>) to generate a library score. When a peak was identified with a library match, the library scores of the two fragmentation spectra (collected at 20 and 40 eV) were averaged. Only averaged library scores greater than 70 were accepted as a potential positive match, eliminating misidentification of potential isomers (<xref rid="F3" ref-type="fig">Figure 3</xref>, <xref rid="F3" ref-type="fig">B</xref>). Library matching requires a relatively broad RT window (&#x000b1; 0.5 minutes) to account for column or solvent variations that may occur since the compound RT was first measured and added to the library. For the analysis of samples, however, a narrower RT window is desired to ensure no false positive identifications or to distinguish between various isomers with similar fragmentation patterns that may all elute within the broad RT window. Therefore, for final identity confirmation, reference standards of all potential positive identifications were analyzed within 24 hours of the initial sample analysis, using the same column and mobile phase batch. The identity of the compound was confirmed when the mass error of the reference standard and unknown were within 5 ppm and the RT difference was less than 0.15 min of each other.</p></sec></sec><sec id="S24"><label>3.2</label><title>Method Validation</title><p id="P27">Extraction efficiency and matrix effects were investigated for the QC compounds (<xref rid="T1" ref-type="table">Table 1</xref>). Data is only shown for 15 ng/mL but matched calculations for 2.0 ng/mL. Plasma extraction efficiencies ranged from 48.9 &#x02013; 91.6%; urine extraction efficiencies ranged from 43.3 &#x02013; 92.1%. The majority of the compounds had extraction efficiencies greater than 80% or above in both matrices. Only 4-ANPP and naloxone had lower extraction efficiencies, which could be attributed to their differences in chemical structures relative to fentanyl analogs. Matrix effects were below the SWGTOX guidelines of 25% with the exception of three compounds for urine and one for plasma (<xref rid="T1" ref-type="table">Table 1</xref>)(<xref rid="R26" ref-type="bibr">Scientific Working Group for Forensic, 2013</xref>). With the exception of fluoroisobutyrylfentanyl, the compounds with high matrix effects eluted at the extremes of the chromatographic run, which coincides with the elution of matrix components.</p><p id="P28">The LRL<sub>100</sub> was determined for the QC compounds (<xref rid="T1" ref-type="table">Table 1</xref>). LRL<sub>100</sub> for these compounds ranged from 0.25 &#x02013; 1.00 ng/mL with the exception of norfentanyl and naloxone which were higher. In addition, LRL<sub>100</sub> were higher in urine than plasma. Compounds with lower extraction efficiencies, higher matrix effects, or a combination had higher LRL<sub>100</sub>. The selected approach to determine LRL resulted in a conservative estimate to best describe method performance across time and variable conditions. Reported concentrations of fentanyl and fentanyl analogs following exposure have varied greatly, with fentanyl, carfentanil, acetylfentanyl, and furanylfentanyl concentrations ranging from 0.0102 ng/mL to 827 ng/mL in human matrices (<xref rid="R6" ref-type="bibr">Butler et al., 2018</xref>; <xref rid="R12" ref-type="bibr">Henderson, 1991</xref>; <xref rid="R13" ref-type="bibr">Martucci et al., 2018</xref>; <xref rid="R15" ref-type="bibr">Mochizuki et al., 2018</xref>; <xref rid="R28" ref-type="bibr">Shanks and Behonick, 2017</xref>; <xref rid="R29" ref-type="bibr">Sofalvi et al., 2017</xref>; <xref rid="R31" ref-type="bibr">Swanson et al., 2017</xref>). Although sensitivity may preclude the detection of all exposures due to delayed sample collection or opioid toxicity, this method has the capability to identify 174 fentanyl related compounds. This method can confirm the presence of analogs based on library match criteria, but the absence of an analyte cannot be definitively reported without characterization of the individual compound LRL.</p><p id="P29">Matrix interferences did not result in the positive identification of library compounds in the analysis of 50 individual urine samples and 50 individual plasma samples. However, fentanyl, acetylfentanyl, fluroisobutrylfentanyl, morphine, and norfentanyl were all positively identified in one of the individual plasma samples. Identification of fentanyl and acetylfentanyl was confirmed with a second method (data not shown). The addition of isotopically labeled standards or the metabolites of drugs commonly associated with fentanyl use did not result in any false positives.</p><p id="P30">Carryover was not observed in matrix blanks following a highly concentrated sample (100 ng/mL). Stability of processed samples was assessed over a period of 24 hours with no decrease in peak area counts.</p></sec><sec id="S25"><label>3.3</label><title>Method Characterization</title><p id="P31">Three quality control materials (QCL, QCH, QCB) were extracted and analyzed in duplicates over the course of 10 days. All QC analytes were positively identified in QCL and QCH across all runs, with the exception of norfentanyl, which had an LRL<sub>100</sub> above QCL concentration. No false positives were detected in the QCB.</p></sec><sec id="S26"><label>3.4</label><title>Analysis of evaluation samples</title><p id="P32">In analysis of the three CAP evaluation samples, eight compounds were positively identified (<xref rid="T2" ref-type="table">Table 2</xref>) with library scores greater than 70 and mass error less than 5 ppm. A contemporaneous reference standard was analyzed within 24 hours for each positive identification and retention times were compared (<xref rid="T2" ref-type="table">Table 2</xref>) to confirm identification.</p><p id="P33">During the analysis of NOB-03, there were three possible isomeric identifications for a single peak: para-fluorofentanyl, meta-fluorofentanyl, and ortho-fluorofentanyl. As demonstrated from the chromatogram of all three standards and the CAP sample peak (<xref rid="F4" ref-type="fig">Figure 4</xref>) the retention time of the sample most closely matches that of para-fluorofentanyl. With the similar retention times and library match we confirmed the peak as para-fluorofentanyl. Without the addition of the FAS Kit and the FAS V1 materials into this work&#x02019;s newly implemented spectral database, the authors would not have known that the method would chromatographically separate the fluorofentanyl isomers ortho, meta, and para. Additionally, if the specimen had contained the ortho or meta isomers, and the laboratory was limited to a reference standard for only the para-fluorofentanyl, the method would not have been able to distinguish the specific fluorofentanyl isomer present, a potentially important piece of information critical to exposure surveillance. The application of the FAS Kit in this work, therefore, demonstrates the ability of the new analytical reference materials to expand opioid testing capabilities. The CAP NOB survey report, received after analysis, confirmed that para-fluorofentanyl was spiked into the sample, in agreement with our identification. Even with retention time tolerances and tight mass error criteria, this demonstrates the importance of analyzing known standards to positively identify unknown peaks, preferably within 24 hours as requested by a number of data reporting programs. In addition to the para-fluorofentanyl, all synthetic opioid-related compounds identified in <xref rid="T2" ref-type="table">table 2</xref> were confirmed by the CAP NOB survey report to be found in the samples indicating there were no false positives. In addition, there were no false negatives, confirmed by the CAP NOB survey report.</p></sec></sec><sec id="S27"><label>4.</label><title>Conclusions</title><p id="P34">A spectral library and detection method for fentanyl analogs and related compounds was developed for exposure analysis in human urine and plasma using LC-QTOF instrumentation. This method was validated for a subset of compounds using SWGTOX guidelines with lower reportable limits ranging from 0.25 to 2.5 ng/mL. The spectral library of 174 compounds used in this work was created to expand the laboratory&#x02019;s opioid testing capabilities for emerging fentanyl-related compounds. The library was heavily influenced by its inclusion of the product line of Traceable Opioid Material<sup>&#x000a7;</sup> Kits, specifically the FAS Kit (120 compounds) and FAS V1 (30 compounds). The effective use of this method was confirmed by its application in the analysis of CAP NOB survey samples, where the correct synthetic opioid-related analytes were identified even when isomers were present. This method provides a much-needed resource toward expanding laboratory synthetic opioid testing capabilities and identifying emerging fentanyl analogs and related compounds in human matrices.</p></sec><sec sec-type="supplementary-material" id="SM1"><title>Supplementary Material</title><supplementary-material content-type="local-data" id="SD1"><label>Supplemental Table 1</label><media xlink:href="NIHMS1581139-supplement-Supplemental_Table_1.docx" orientation="portrait" id="d36e740" position="anchor"/></supplementary-material></sec></body><back><ack id="S28"><title>Acknowledgements</title><p id="P35"><sup>&#x000a7;</sup>TRACEABLE OPIOID MATERIAL, TOM KITS, and the TOM KITS logo are marks of the U.S. Department of Health and Human Services.</p><p id="P36">The CDC appreciates the College of American Pathologists&#x02019; (CAP) assistance in providing essential information of CAP proficiency testing samples used in this program.</p><p id="P37">This work was funded through CDC&#x02019;s National Center for Injury prevention and Control. The authors would like to especially thank the National Center for Injury Prevention and Control and the many CDC offices that provided support in the areas of contracting, policy, communications, ethics, technology transfer, general counsel, and administrative services.</p></ack><fn-group><fn id="FN1"><p id="P38" content-type="publisher-disclaimer">Disclaimer</p></fn><fn id="FN2"><p id="P39" content-type="publisher-disclaimer">The findings and conclusions in this study are those of the authors and do not necessarily represent the views of the U.S. Department of Health and Human Services, or the U.S. Centers for Disease Control and Prevention. Use of trade names and commercial sources is for identification only and does not constitute endorsement by the U.S. Department of Health and Human Services, or the U.S. Centers for Disease Control and Prevention.</p></fn><fn fn-type="COI-statement" id="FN3"><p id="P40">The authors have no competing interests to declare.</p></fn></fn-group><ref-list><title>References</title><ref id="R1"><mixed-citation publication-type="web"><source>Fentanyl Analog Screening Kits</source>. <comment><ext-link ext-link-type="uri" xlink:href="https://www.caymanchem.com/forensics/faskit/">https://www.caymanchem.com/forensics/faskit/</ext-link>.</comment>
<comment>Access Date</comment>
<date-in-citation>07/02/2019</date-in-citation>.</mixed-citation></ref><ref id="R2"><mixed-citation publication-type="book"><collab>United Nations Office on Drugs and Crime</collab>, <year>2017</year>
<source>Fentanyl and its Analogues - 50 Years On. Global Smart Update</source>. <publisher-name>UNODC</publisher-name>, <publisher-loc>Vienna, Austria</publisher-loc>.</mixed-citation></ref><ref id="R3"><mixed-citation publication-type="journal"><name><surname>Angelini</surname><given-names>DJ</given-names></name>, <name><surname>Biggs</surname><given-names>TD</given-names></name>, <name><surname>Maughan</surname><given-names>MN</given-names></name>, <name><surname>Feasel</surname><given-names>MG</given-names></name>, <name><surname>Sisco</surname><given-names>E</given-names></name>, <name><surname>Sekowski</surname><given-names>JW</given-names></name>, <year>2019</year>
<article-title>Evaluation of a lateral flow immunoassay for the detection of the synthetic opioid fentanyl</article-title>. <source>Forensic Sci Int</source>
<volume>300</volume>, <fpage>75</fpage>&#x02013;<lpage>81</lpage>.<pub-id pub-id-type="pmid">31078080</pub-id></mixed-citation></ref><ref id="R4"><mixed-citation publication-type="journal"><name><surname>Buchalter</surname><given-names>S</given-names></name>, <name><surname>Marginean</surname><given-names>I</given-names></name>, <name><surname>Yohannan</surname><given-names>J</given-names></name>, <name><surname>Lurie</surname><given-names>IS</given-names></name>, <year>2019</year>
<article-title>Gas chromatography with tandem cold electron ionization mass spectrometric detection and vacuum ultraviolet detection for the comprehensive analysis of fentanyl analogues</article-title>. <source>Journal of Chromatography A</source>
<volume>1596</volume>, <fpage>183</fpage>&#x02013;<lpage>193</lpage>.<pub-id pub-id-type="pmid">30876740</pub-id></mixed-citation></ref><ref id="R5"><mixed-citation publication-type="journal"><name><surname>Busardo</surname><given-names>FP</given-names></name>, <name><surname>Carlier</surname><given-names>J</given-names></name>, <name><surname>Giorgetti</surname><given-names>R</given-names></name>, <name><surname>Tagliabracci</surname><given-names>A</given-names></name>, <name><surname>Pacifici</surname><given-names>R</given-names></name>, <name><surname>Gottardi</surname><given-names>M</given-names></name>, <name><surname>Pichini</surname><given-names>S</given-names></name>, <year>2019</year>
<article-title>Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry Assay for Quantifying Fentanyl and 22 Analogs and Metabolites in Whole Blood, Urine, and Hair</article-title>. <source>Front Chem</source>
<volume>7</volume>, <fpage>184</fpage>.<pub-id pub-id-type="pmid">31001514</pub-id></mixed-citation></ref><ref id="R6"><mixed-citation publication-type="journal"><name><surname>Butler</surname><given-names>DC</given-names></name>, <name><surname>Shanks</surname><given-names>K</given-names></name>, <name><surname>Behonick</surname><given-names>GS</given-names></name>, <name><surname>Smith</surname><given-names>D</given-names></name>, <name><surname>Presnell</surname><given-names>SE</given-names></name>, <name><surname>Tormos</surname><given-names>LM</given-names></name>, <year>2018</year>
<article-title>Three Cases of Fatal Acrylfentanyl Toxicity in the United States and a Review of Literature</article-title>. <source>J Anal Toxicol</source>
<volume>42</volume>, <fpage>e6</fpage>&#x02013;<lpage>e11</lpage>.<pub-id pub-id-type="pmid">29036502</pub-id></mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>Campos-Ma&#x000f1;as</surname><given-names>MC</given-names></name>, <name><surname>Ferrer</surname><given-names>I</given-names></name>, <name><surname>Thurman</surname><given-names>EM</given-names></name>, <name><surname>S&#x000e1;nchez P&#x000e9;rez</surname><given-names>JA</given-names></name>, <name><surname>Ag&#x000fc;era</surname><given-names>A</given-names></name>, <year>2019</year>
<article-title>Identification of opioids in surface and wastewaters by LC/QTOF-MS using retrospective data analysis</article-title>. <source>Science of The Total Environment</source>
<volume>664</volume>, <fpage>874</fpage>&#x02013;<lpage>884</lpage>.<pub-id pub-id-type="pmid">30769311</pub-id></mixed-citation></ref><ref id="R8"><mixed-citation publication-type="web"><collab>DEA</collab>, <year>2018</year>
<source>2018 Emerging Threat Report</source>. <comment><ext-link ext-link-type="uri" xlink:href="https://ndews.umd.edu/resources/dea-emerging-threat-reports">https://ndews.umd.edu/resources/dea-emerging-threat-reports</ext-link>.</comment>
<comment>Access Date:</comment>
<date-in-citation>6/26/2019</date-in-citation>.</mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Fogarty</surname><given-names>MF</given-names></name>, <name><surname>Papsun</surname><given-names>DM</given-names></name>, <name><surname>Logan</surname><given-names>BK</given-names></name>, <year>2018</year>
<article-title>Analysis of Fentanyl and 18 Novel Fentanyl Analogs and Metabolites by LC&#x02013;MS-MS, and report of Fatalities Associated with Methoxyacetylfentanyl and Cyclopropylfentanyl</article-title>. <source>Journal of Analytical Toxicology</source>
<volume>42</volume>, <fpage>592</fpage>&#x02013;<lpage>604</lpage>.<pub-id pub-id-type="pmid">29750250</pub-id></mixed-citation></ref><ref id="R10"><mixed-citation publication-type="journal"><name><surname>Gillespie</surname><given-names>TJ</given-names></name>, <name><surname>Gandolfi</surname><given-names>AJ</given-names></name>, <name><surname>Vaughan</surname><given-names>RW</given-names></name>, <year>1981</year>
<article-title>Gas Chromatographic Determination of Fentanyl and its Analogues in Human Plasma</article-title>. <source>Journal of Analytical Toxicology</source>
<volume>5</volume>, <fpage>133</fpage>&#x02013;<lpage>137</lpage>.<pub-id pub-id-type="pmid">6115094</pub-id></mixed-citation></ref><ref id="R11"><mixed-citation publication-type="journal"><name><surname>Guerrieri</surname><given-names>D</given-names></name>, <name><surname>Kjellqvist</surname><given-names>F</given-names></name>, <name><surname>Kronstrand</surname><given-names>R</given-names></name>, <name><surname>Green</surname><given-names>H</given-names></name>, <year>2019</year>
<article-title>Validation and Cross-Reactivity Data for Fentanyl Analogs With the Immunalysis Fentanyl ELISA</article-title>. <source>J Anal Toxicol</source>
<volume>43</volume>, <fpage>18</fpage>&#x02013;<lpage>24</lpage>.<pub-id pub-id-type="pmid">30215771</pub-id></mixed-citation></ref><ref id="R12"><mixed-citation publication-type="journal"><name><surname>Henderson</surname><given-names>GL</given-names></name>, <year>1991</year>
<article-title>Fentanyl-Related Deaths Demographics, Circumstances, and Toxicology of 112 Cases</article-title>. <source>Journal of Forensic Sciences</source>, <fpage>422</fpage>&#x02013;<lpage>433</lpage>.<pub-id pub-id-type="pmid">2066723</pub-id></mixed-citation></ref><ref id="R13"><mixed-citation publication-type="journal"><name><surname>Martucci</surname><given-names>HFH</given-names></name>, <name><surname>Ingle</surname><given-names>EA</given-names></name>, <name><surname>Hunter</surname><given-names>MD</given-names></name>, <name><surname>Rodda</surname><given-names>LN</given-names></name>, <year>2018</year>
<article-title>Distribution of furanyl fentanyl and 4-ANPP in an accidental acute death: A case report</article-title>. <source>Forensic Science International</source>
<volume>283</volume>, <fpage>e13</fpage>&#x02013;<lpage>e17</lpage>.<pub-id pub-id-type="pmid">29254806</pub-id></mixed-citation></ref><ref id="R14"><mixed-citation publication-type="journal"><name><surname>Misailidi</surname><given-names>N</given-names></name>, <name><surname>Athanaselis</surname><given-names>S</given-names></name>, <name><surname>Nikolaou</surname><given-names>P</given-names></name>, <name><surname>Katselou</surname><given-names>M</given-names></name>, <name><surname>Dotsikas</surname><given-names>Y</given-names></name>, <name><surname>Spiliopoulou</surname><given-names>C</given-names></name>, <name><surname>Papoutsis</surname><given-names>I</given-names></name>, <year>2019</year>
<article-title>A GC-MS method for the determination of furanylfentanyl and ocfentanil in whole blood with full validation</article-title>. <source>Forensic Toxicol</source>
<volume>37</volume>, <fpage>238</fpage>&#x02013;<lpage>244</lpage>.<pub-id pub-id-type="pmid">30636990</pub-id></mixed-citation></ref><ref id="R15"><mixed-citation publication-type="journal"><name><surname>Mochizuki</surname><given-names>A</given-names></name>, <name><surname>Nakazawa</surname><given-names>H</given-names></name>, <name><surname>Adachi</surname><given-names>N</given-names></name>, <name><surname>Takekawa</surname><given-names>K</given-names></name>, <name><surname>Shojo</surname><given-names>H</given-names></name>, <year>2018</year>
<article-title>Postmortem distribution of mepirapim and acetyl fentanyl in biological fluid and solid tissue specimens measured by the standard addition method</article-title>. <source>Forensic Toxicology</source>
<volume>37</volume>, <fpage>27</fpage>&#x02013;<lpage>33</lpage>.<pub-id pub-id-type="pmid">30636981</pub-id></mixed-citation></ref><ref id="R16"><mixed-citation publication-type="journal"><name><surname>Mojica</surname><given-names>MA</given-names></name>, <name><surname>Carter</surname><given-names>MD</given-names></name>, <name><surname>Isenberg</surname><given-names>SL</given-names></name>, <name><surname>Pirkle</surname><given-names>JL</given-names></name>, <name><surname>Hamelin</surname><given-names>EI</given-names></name>, <name><surname>Shaner</surname><given-names>RL</given-names></name>, <name><surname>Seymour</surname><given-names>C</given-names></name>, <name><surname>Sheppard</surname><given-names>CI</given-names></name>, <name><surname>Baldwin</surname><given-names>GT</given-names></name>, <name><surname>Johnson</surname><given-names>RC</given-names></name>, <year>2019</year>
<article-title>Designing traceable opioid material* kits to improve laboratory testing during the U.S. opioid crisis</article-title>. <source>Toxicology Letters</source>
<volume>317</volume>, <fpage>53</fpage>&#x02013;<lpage>58</lpage>.<pub-id pub-id-type="pmid">31560942</pub-id></mixed-citation></ref><ref id="R17"><mixed-citation publication-type="journal"><name><surname>Mounteney</surname><given-names>J</given-names></name>, <name><surname>Giraudon</surname><given-names>I</given-names></name>, <name><surname>Denissov</surname><given-names>G</given-names></name>, <name><surname>Griffiths</surname><given-names>P</given-names></name>, <year>2015</year>
<article-title>Fentanyls: Are we missing the signs? Highly potent and on the rise in Europe</article-title>. <source>International Journal of Drug Policy</source>
<volume>26</volume>, <fpage>626</fpage>&#x02013;<lpage>631</lpage>.<pub-id pub-id-type="pmid">25976511</pub-id></mixed-citation></ref><ref id="R18"><mixed-citation publication-type="journal"><name><surname>Noble</surname><given-names>C</given-names></name>, <name><surname>Weihe Dalsgaard</surname><given-names>P</given-names></name>, <name><surname>Stybe Johansen</surname><given-names>S</given-names></name>, <name><surname>Linnet</surname><given-names>K</given-names></name>, <year>2018</year>
<article-title>Application of a screening method for fentanyl and its analogues using UHPLC-QTOF-MS with data-independent acquisition (DIA) in MS(E) mode and retrospective analysis of authentic forensic blood samples</article-title>. <source>Drug Test Anal</source>
<volume>10</volume>, <fpage>651</fpage>&#x02013;<lpage>662</lpage>.<pub-id pub-id-type="pmid">28834382</pub-id></mixed-citation></ref><ref id="R19"><mixed-citation publication-type="journal"><name><surname>Palamar</surname><given-names>JJ</given-names></name>, <name><surname>Salomone</surname><given-names>A</given-names></name>, <name><surname>Bigiarini</surname><given-names>R</given-names></name>, <name><surname>Vincenti</surname><given-names>M</given-names></name>, <name><surname>Acosta</surname><given-names>P</given-names></name>, <name><surname>Tofighi</surname><given-names>B</given-names></name>, <year>2019</year>
<article-title>Testing hair for fentanyl exposure: a method to inform harm reduction behavior among individuals who use heroin</article-title>. <source>Am J Drug Alcohol Abuse</source>
<volume>45</volume>, <fpage>90</fpage>&#x02013;<lpage>96</lpage>.<pub-id pub-id-type="pmid">30601034</pub-id></mixed-citation></ref><ref id="R20"><mixed-citation publication-type="journal"><name><surname>Palmquist</surname><given-names>KB</given-names></name>, <name><surname>Swortwood</surname><given-names>MJ</given-names></name>, <year>2019</year>
<article-title>Data-independent screening method for 14 fentanyl analogs in whole blood and oral fluid using LC-QTOF-MS</article-title>. <source>Forensic Sci Int</source>
<volume>297</volume>, <fpage>189</fpage>&#x02013;<lpage>197</lpage>.<pub-id pub-id-type="pmid">30802648</pub-id></mixed-citation></ref><ref id="R21"><mixed-citation publication-type="journal"><name><surname>Partridge</surname><given-names>E</given-names></name>, <name><surname>Trobbiani</surname><given-names>S</given-names></name>, <name><surname>Stockham</surname><given-names>P</given-names></name>, <name><surname>Charlwood</surname><given-names>C</given-names></name>, <name><surname>Kostakis</surname><given-names>C</given-names></name>, <year>2018</year>
<article-title>A Case Study Involving U-47700, Diclazepam and Flubromazepam-Application of Retrospective Analysis of HRMS Data</article-title>. <source>J Anal Toxicol</source>
<volume>42</volume>, <fpage>655</fpage>&#x02013;<lpage>660</lpage>.<pub-id pub-id-type="pmid">29945197</pub-id></mixed-citation></ref><ref id="R22"><mixed-citation publication-type="journal"><name><surname>Ruangyuttikam</surname><given-names>W</given-names></name>, <name><surname>Law</surname><given-names>MY</given-names></name>, <name><surname>Rollins</surname><given-names>DE</given-names></name>, <name><surname>Moody</surname><given-names>DE</given-names></name>, <year>1990</year>
<article-title>Detection of Fentanyl and its Analogs by Enzyme-Linked Immunosorbent Assay</article-title>. <source>Journal of Analytical Toxicology</source>
<volume>14</volume>, <fpage>160</fpage>&#x02013;<lpage>164</lpage>.<pub-id pub-id-type="pmid">2374405</pub-id></mixed-citation></ref><ref id="R23"><mixed-citation publication-type="journal"><name><surname>Salomone</surname><given-names>A</given-names></name>, <name><surname>Palamar</surname><given-names>JJ</given-names></name>, <name><surname>Bigiarini</surname><given-names>R</given-names></name>, <name><surname>Gerace</surname><given-names>E</given-names></name>, <name><surname>Di Corcia</surname><given-names>D</given-names></name>, <name><surname>Vincenti</surname><given-names>M</given-names></name>, <year>2019</year>
<article-title>Detection of Fentanyl Analogs and Synthetic Opioids in Real Hair Samples</article-title>. <source>J Anal Toxicol</source>
<volume>43</volume>, <fpage>259</fpage>&#x02013;<lpage>265</lpage>.<pub-id pub-id-type="pmid">30462247</pub-id></mixed-citation></ref><ref id="R24"><mixed-citation publication-type="journal"><name><surname>Scholl</surname><given-names>L</given-names></name>, <name><surname>Seth</surname><given-names>P</given-names></name>, <name><surname>Kariisa</surname><given-names>M</given-names></name>, <name><surname>Wilson</surname><given-names>N</given-names></name>, <name><surname>Baldwin</surname><given-names>G</given-names></name>, <year>2019</year>
<article-title>Drugs and Opioid Involved Overdose Deaths - United States 2013&#x02013;2017</article-title>. <source>Morbidity and Mortality Weekly Report</source>
<volume>67</volume>, <fpage>1419</fpage>&#x02013;<lpage>1427</lpage>.</mixed-citation></ref><ref id="R25"><mixed-citation publication-type="journal"><name><surname>Schuttler</surname><given-names>J</given-names></name>, <name><surname>White</surname><given-names>PF</given-names></name>, <year>1984</year>
<article-title>Optimization of the Radioimmunoassays for Measureing Fentanyl and Alfentanil in Human Serum</article-title>. <source>Anesthesiology</source>
<volume>61</volume>, <fpage>315</fpage>&#x02013;<lpage>320</lpage>.<pub-id pub-id-type="pmid">6433750</pub-id></mixed-citation></ref><ref id="R26"><mixed-citation publication-type="journal"><collab>Scientific Working Group for Forensic, T.</collab>, <year>2013</year>
<article-title>Scientific Working Group for Forensic Toxicology (SWGTOX) standard practices for method validation in forensic toxicology</article-title>. <source>J Anal Toxicol</source>
<volume>37</volume>, <fpage>452</fpage>&#x02013;<lpage>474</lpage>.<pub-id pub-id-type="pmid">23934984</pub-id></mixed-citation></ref><ref id="R27"><mixed-citation publication-type="journal"><name><surname>Seymour</surname><given-names>C</given-names></name>, <name><surname>Shaner</surname><given-names>RL</given-names></name>, <name><surname>Feyereisen</surname><given-names>MC</given-names></name>, <name><surname>Wharton</surname><given-names>RE</given-names></name>, <name><surname>Kaplan</surname><given-names>P</given-names></name>, <name><surname>Hamelin</surname><given-names>EI</given-names></name>, <name><surname>Johnson</surname><given-names>RC</given-names></name>, <year>2019</year>
<article-title>Determination of Fentanyl Analog Exposure Using Dried Blood Spots with LC-MS-MS</article-title>. <source>J Anal Toxicol</source>
<volume>43</volume>, <fpage>266</fpage>&#x02013;<lpage>276</lpage>.<pub-id pub-id-type="pmid">30462229</pub-id></mixed-citation></ref><ref id="R28"><mixed-citation publication-type="journal"><name><surname>Shanks</surname><given-names>KG</given-names></name>, <name><surname>Behonick</surname><given-names>GS</given-names></name>, <year>2017</year>
<article-title>Detection of Carfentanil by LC-MS-MS and Reports of Associated Fatalities in the USA</article-title>. <source>J Anal Toxicol</source>
<volume>41</volume>, <fpage>466</fpage>&#x02013;<lpage>472</lpage>.<pub-id pub-id-type="pmid">28830120</pub-id></mixed-citation></ref><ref id="R29"><mixed-citation publication-type="journal"><name><surname>Sofalvi</surname><given-names>S</given-names></name>, <name><surname>Schueler</surname><given-names>HE</given-names></name>, <name><surname>Lavins</surname><given-names>ES</given-names></name>, <name><surname>Kaspar</surname><given-names>CK</given-names></name>, <name><surname>Brooker</surname><given-names>IT</given-names></name>, <name><surname>Mazzola</surname><given-names>CD</given-names></name>, <name><surname>Dolinak</surname><given-names>D</given-names></name>, <name><surname>Gilson</surname><given-names>TP</given-names></name>, <name><surname>Perch</surname><given-names>S</given-names></name>, <year>2017</year>
<article-title>An LC&#x02013;MS-MS Method for the Analysis of Carfentanil, 3-Methylfentanyl, 2-Furanyl Fentanyl, Acetyl Fentanyl, Fentanyl and Norfentanyl in Postmortem and Impaired-Driving Cases</article-title>. <source>Journal of Analytical Toxicology</source>
<volume>41</volume>, <fpage>473</fpage>&#x02013;<lpage>483</lpage>.<pub-id pub-id-type="pmid">28830122</pub-id></mixed-citation></ref><ref id="R30"><mixed-citation publication-type="journal"><name><surname>Strayer</surname><given-names>KE</given-names></name>, <name><surname>Antonides</surname><given-names>HM</given-names></name>, <name><surname>Juhascik</surname><given-names>MP</given-names></name>, <name><surname>Daniulaityte</surname><given-names>R</given-names></name>, <name><surname>Sizemore</surname><given-names>IE</given-names></name>, <year>2018</year>
<article-title>LC-MS/MS-Based Method for the Multiplex Detection of 24 Fentanyl Analogues and Metabolites in Whole Blood at Sub ng mL(&#x02212;1) Concentrations</article-title>. <source>ACS Omega</source>
<volume>3</volume>, <fpage>514</fpage>&#x02013;<lpage>523</lpage>.<pub-id pub-id-type="pmid">29399650</pub-id></mixed-citation></ref><ref id="R31"><mixed-citation publication-type="journal"><name><surname>Swanson</surname><given-names>DM</given-names></name>, <name><surname>Hair</surname><given-names>LS</given-names></name>, <name><surname>Strauch Rivers</surname><given-names>SR</given-names></name>, <name><surname>Smyth</surname><given-names>BC</given-names></name>, <name><surname>Brogan</surname><given-names>SC</given-names></name>, <name><surname>Ventoso</surname><given-names>AD</given-names></name>, <name><surname>Vaccaro</surname><given-names>SL</given-names></name>, <name><surname>Pearson</surname><given-names>JM</given-names></name>, <year>2017</year>
<article-title>Fatalities Involving Carfentanil and Furanyl Fentanyl: Two Case Reports</article-title>. <source>Journal of Analytical Toxicology</source>
<volume>41</volume>, <fpage>498</fpage>&#x02013;<lpage>502</lpage>.<pub-id pub-id-type="pmid">28575422</pub-id></mixed-citation></ref><ref id="R32"><mixed-citation publication-type="journal"><name><surname>Van Rooy</surname><given-names>HH</given-names></name>, <year>1981</year>
<article-title>The assay of fentanyl and its metabolites in plasma of patients using gas chromatography with alkali flame ionisation detection and gas chromatography-mass spectrometry</article-title>. <source>JOurnal of Chromatography</source>
<volume>233</volume>, <fpage>85</fpage>&#x02013;<lpage>93</lpage>.</mixed-citation></ref><ref id="R33"><mixed-citation publication-type="journal"><name><surname>Vardanyan</surname><given-names>RS</given-names></name>, <name><surname>Hruby</surname><given-names>VJ</given-names></name>, <year>2014</year>
<article-title>Fentanyl-related compounds and derivatives: current status and future prospects for pharmaceutical applications</article-title>. <source>Future Med Chem</source>
<volume>6</volume>, <fpage>385</fpage>&#x02013;<lpage>412</lpage>.<pub-id pub-id-type="pmid">24635521</pub-id></mixed-citation></ref><ref id="R34"><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>G</given-names></name>, <name><surname>Huynh</surname><given-names>K</given-names></name>, <name><surname>Barhate</surname><given-names>R</given-names></name>, <name><surname>Rodrigues</surname><given-names>W</given-names></name>, <name><surname>Moore</surname><given-names>C</given-names></name>, <name><surname>Coulter</surname><given-names>C</given-names></name>, <name><surname>Vincent</surname><given-names>M</given-names></name>, <name><surname>Soares</surname><given-names>J</given-names></name>, <year>2011</year>
<article-title>Development of a homogeneous immunoassay for the detection of fentanyl in urine</article-title>. <source>Forensic Sci Int</source>
<volume>206</volume>, <fpage>127</fpage>&#x02013;<lpage>131</lpage>.<pub-id pub-id-type="pmid">20801588</pub-id></mixed-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Figure 1.</label><caption><p id="P41">TIC of all compounds in the quality control solution at 15 ng/mL in water after LC-QTOF analysis. Quality control solution contains a total of eight different fentanyl related compounds in addition to fentanyl. six of these compounds are fentanyl analogs, one is a synthetic precursor (4-ANPP), and one is a metabolite (norfentanyl). Naloxone is also studied due to its usage as treatment against opioid exposure.</p></caption><graphic xlink:href="nihms-1581139-f0002"/></fig><fig id="F2" orientation="portrait" position="float"><label>Figure 2.</label><caption><p id="P42">Extracted Ion Chromatogram (<italic>m/z</italic> 337.2278 &#x000b1; 0.0005) of fentanyl. Red diamonds indicate when MS/MS spectra were acquired, as triggered by the Auto MS/MS mode.</p></caption><graphic xlink:href="nihms-1581139-f0003"/></fig><fig id="F3" orientation="portrait" position="float"><label>Figure 3.</label><caption><p id="P43">Comparison of fragmentation spectra between <bold>A</bold>) acetylfentanyl and its reference standard within the library, and <bold>B</bold>) 4&#x02019;-methyl acetylfentanyl and its isomer fentanyl. Acetylfentanyl has a close match with its reference standard giving a high match score of 99.12. Despite fentanyl and 4&#x02019;-methyl acetylfentanyl being isomers, they have different fragmentation patterns due to the differing location of a methyl group, resulting in a poor match score (25.12) of 4&#x02019;-methyl acetylfentanyl relative to the fentanyl.</p></caption><graphic xlink:href="nihms-1581139-f0004"/></fig><fig id="F4" orientation="portrait" position="float"><label>Figure 4.</label><caption><p id="P44">Extracted ion chromatrogram (<italic>m/z</italic> 355.2185 &#x000b1; 0.0005) overlay of the evaluation sample NOB-03 (green) and separate standards of para-fluorofentanyl (pink), meta-fluorofentanyl (red), and ortho-fluorofentanyl (blue) from the FAS Kit (all isomers). The evaluation sample was positively identified as the para-fluorofentanyl isomer due to the similar retention times.</p></caption><graphic xlink:href="nihms-1581139-f0005"/></fig><table-wrap id="T1" position="float" orientation="portrait"><label>Table 1.</label><caption><p id="P45">Evaluation of analyte matrix effects, extraction efficiency, and lower reportable limit (LRL<sub>100</sub>) in plasma and urine. Matrix effects and extraction efficiency shown is at 15 ng/mL.</p></caption><table frame="box" rules="all"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th rowspan="2" align="center" valign="middle" colspan="1">Analyte</th><th colspan="3" align="center" valign="middle" rowspan="1">Plasma</th><th colspan="3" align="center" valign="middle" rowspan="1">Urine</th></tr><tr><th align="center" valign="middle" rowspan="1" colspan="1">Matrix Effects (%)</th><th align="center" valign="middle" rowspan="1" colspan="1">Extraction Efficiency (%)</th><th align="center" valign="middle" rowspan="1" colspan="1">LRL<sub>100</sub> (ng/mL)</th><th align="center" valign="middle" rowspan="1" colspan="1">Matrix Effects (%)</th><th align="center" valign="middle" rowspan="1" colspan="1">Extraction Efficiency (%)</th><th align="center" valign="middle" rowspan="1" colspan="1">LRL<sub>100</sub> (ng/mL)</th></tr></thead><tbody><tr><td align="center" valign="middle" rowspan="1" colspan="1">Fentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;14.4</td><td align="center" valign="middle" rowspan="1" colspan="1">82.4</td><td align="center" valign="middle" rowspan="1" colspan="1">0.50</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;17.6</td><td align="center" valign="middle" rowspan="1" colspan="1">86.7</td><td align="center" valign="middle" rowspan="1" colspan="1">0.50</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Acetylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;10.5</td><td align="center" valign="middle" rowspan="1" colspan="1">85.2</td><td align="center" valign="middle" rowspan="1" colspan="1">0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;11.2</td><td align="center" valign="middle" rowspan="1" colspan="1">88.6</td><td align="center" valign="middle" rowspan="1" colspan="1">0.75</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Carfentanil</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;12.2</td><td align="center" valign="middle" rowspan="1" colspan="1">84.0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.75</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;16.5</td><td align="center" valign="middle" rowspan="1" colspan="1">88.6</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Cyclopropylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;14.2</td><td align="center" valign="middle" rowspan="1" colspan="1">86.5</td><td align="center" valign="middle" rowspan="1" colspan="1">0.75</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;18.0</td><td align="center" valign="middle" rowspan="1" colspan="1">85.1</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Fluoroisobutyrylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;23.1</td><td align="center" valign="middle" rowspan="1" colspan="1">86.4</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;27.1</td><td align="center" valign="middle" rowspan="1" colspan="1">87.0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.75</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Furanylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;10.1</td><td align="center" valign="middle" rowspan="1" colspan="1">81.5</td><td align="center" valign="middle" rowspan="1" colspan="1">2.50</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;14.8</td><td align="center" valign="middle" rowspan="1" colspan="1">81.7</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Methoxyacethylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;9.2</td><td align="center" valign="middle" rowspan="1" colspan="1">82.0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.50</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;9.3</td><td align="center" valign="middle" rowspan="1" colspan="1">88.1</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">4-ANPP</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;12.3</td><td align="center" valign="middle" rowspan="1" colspan="1">63.1</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;17.6</td><td align="center" valign="middle" rowspan="1" colspan="1">71.3</td><td align="center" valign="middle" rowspan="1" colspan="1">1.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Norfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;17.5</td><td align="center" valign="middle" rowspan="1" colspan="1">91.6</td><td align="center" valign="middle" rowspan="1" colspan="1">2.50</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;54.5</td><td align="center" valign="middle" rowspan="1" colspan="1">92.1</td><td align="center" valign="middle" rowspan="1" colspan="1">5.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Naloxone</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;26.1</td><td align="center" valign="middle" rowspan="1" colspan="1">48.9</td><td align="center" valign="middle" rowspan="1" colspan="1">2.50</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;31.6</td><td align="center" valign="middle" rowspan="1" colspan="1">43.3</td><td align="center" valign="middle" rowspan="1" colspan="1">5.00</td></tr></tbody></table></table-wrap><table-wrap id="T2" position="float" orientation="portrait"><label>Table 2.</label><caption><p id="P46">Positive compound confirmations from three spiked whole blood CAP evaluation samples.</p></caption><table frame="box" rules="all"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="center" valign="middle" rowspan="1" colspan="1">Sample ID</th><th align="center" valign="middle" rowspan="1" colspan="1">Compounds Identified</th><th align="center" valign="middle" rowspan="1" colspan="1">&#x00394;RT* (min)</th><th align="center" valign="middle" rowspan="1" colspan="1">Mass Error (ppm)</th><th align="center" valign="middle" rowspan="1" colspan="1">Library Score</th></tr></thead><tbody><tr><td rowspan="3" align="center" valign="middle" colspan="1">NOB-01</td><td align="center" valign="middle" rowspan="1" colspan="1">Acetylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.72</td><td align="center" valign="middle" rowspan="1" colspan="1">99.1</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Acrylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">1.55</td><td align="center" valign="middle" rowspan="1" colspan="1">96.3</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Carfentanil</td><td align="center" valign="middle" rowspan="1" colspan="1">0.06</td><td align="center" valign="middle" rowspan="1" colspan="1">1.03</td><td align="center" valign="middle" rowspan="1" colspan="1">95.5</td></tr><tr><td rowspan="3" align="center" valign="middle" colspan="1">NOB-02</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x003b1;-Methylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">1.04</td><td align="center" valign="middle" rowspan="1" colspan="1">98.8</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">4-ANPP</td><td align="center" valign="middle" rowspan="1" colspan="1">0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">1.50</td><td align="center" valign="middle" rowspan="1" colspan="1">99.6</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Furanylfentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">1.53</td><td align="center" valign="middle" rowspan="1" colspan="1">91.4</td></tr><tr><td rowspan="2" align="center" valign="middle" colspan="1">NOB-03</td><td align="center" valign="middle" rowspan="1" colspan="1">para-Fluorofentanyl</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">1.50</td><td align="center" valign="middle" rowspan="1" colspan="1">98.4</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">U-47700</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">1.67</td><td align="center" valign="middle" rowspan="1" colspan="1">99.1</td></tr></tbody></table></table-wrap></floats-group></article>