Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Establishment Of An Experimental System For Measring Biodynamic Response Of Hand-Arm - Introduction; Proceedings Of The First American Conference On Human Vibration

Filetype[PDF-191.06 KB]


  • English

  • Details:

    • Description:
      This paper addresses establishment of an experimental system for measuring biodynamic response (BR) of hand-arm system at the NIIH in Japan. BR measurement system at the NIIH is nearly equivalent to NIOSH installed system. The feasibility of the system is examined through the apparent mass (AM) measurement of the empty handle and a set of calibration masses. Apparatus The grip force was measured by using the handle shown in Fig. 1. The handle has two force sensors (KISTLER, 9212) and one accelerometer (PCB, 356A12). A low-pass filter with 5 Hz cut-off frequency was used to the grip force from measured force signal. Figure 2 shows BR measurement system in this study. The push or pull force at the handle was measured by using the force plate (KISTLER, 9286AA). The grip force and the push / pull force were displayed on a monitor. The shaker (IMV, VE-100S) is used to vibrate the hand-arm system along the forearm axis (Zh direction) (ISO 10068, 1998; ISO 5349-1, 2001). In most situations force actions for operating tools are expressed by grip, push, pull and combined these actions. These actions can be simulated in the test system. AM was obtained by performing H1 estimator in the PULSETM system (B&K, 3109) and it is denoted at the one-third octave band center frequencies. [ ] Methods In order to investigate the reliability of the system, AM measurement of the handle was performed. It is assumed that the handle is rigid in the upper limit of adoptive frequency range in this study. This assumption is validated in AM measurement of the empty handle. A pseudo-random vibration in the frequency range of 10 to 1,250 Hz was used and its amplitude is 1.0 (m/s2)2/Hz with a flat power spectral density (PSD) in the experiment. Measured AM includes the mass effect of the measuring cap in a subject experiment. Compensated apparent mass AMc(?) is obtained by Eq. (1) 1-2.
    • Subjects:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov