Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Assessments And Refinements Of An Anthropodynamic Manikin For Seating Dynamics Applications - Introduction; Proceedings Of The First American Conference On Human Vibration

Filetype[PDF-179.69 KB]


  • English

  • Details:

    • Description:
      The current laboratory methods for assessing the vibration attenuation performance of seats involve repetitive trials with a number of human occupants, and raise certain ethical concerns. Moreover, the measurements with human subjects yield considerable variability in the data. Alternatively, several anthropodynamic manikins have been developed for effective assessments of the coupled seat occupant system [1]. The effectiveness of a manikin in predicting the response of a coupled seat-occupant system lies in its ability to reproduce the biodynamic response of the seated human body in terms of force-motion relationship at the body-seat interface, such as apparent mass (APMS). A number of prototype manikins have thus been developed on the basis of biodynamic characteristics of vertical vibration-exposed seated occupants of different body masses in the vicinity of 5th, 50th and 95th percentile male population. This study concerns with the analysis of a passive prototype manikin to enhance its ability to reproduce the idealized APMS response characteristics of the vibration-exposed seated human subjects defined in ISO-5982[2] for mean body masses of 55, 75 and 98 kg. Methods The APMS responses of a prototype anthropodynamic passive manikin were thoroughly characterized in the laboratory under different excitations and body mass configurations. The manikin was designed with sufficient flexibility to configure mechanical-equivalent models corresponding to seated body masses of 55, 75 and 98 kg, by adding/removing specified masses and springs (Fig. 1). The manikin, configured for a specific body mass, was positioned on a rigid seat without a backrest, which was fixed to the force platform of a whole-body vertical vibration simulator. The simulator was programmed to synthesize random vertical vibration with flat acceleration power spectrum in the 0.4-20 Hz frequency range with two different magnitudes: 1 and 2 m/s2 overall rms acceleration. The total static and dynamic forces of the manikin to and the seat were measured using the force platform, while a single axis accelerometer was installed on the seat pan to measure acceleration due to vertical excitation. The measured data was appropriately corrected for the rigid seat inertia force, and the apparent mass [ ]
    • Subjects:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov