<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.2 20190208//EN" "JATS-archivearticle1-mathml3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties open_access?><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101262796</journal-id><journal-id journal-id-type="pubmed-jr-id">32819</journal-id><journal-id journal-id-type="nlm-ta">J Expo Sci Environ Epidemiol</journal-id><journal-id journal-id-type="iso-abbrev">J Expo Sci Environ Epidemiol</journal-id><journal-title-group><journal-title>Journal of exposure science &#x00026; environmental epidemiology</journal-title></journal-title-group><issn pub-type="ppub">1559-0631</issn><issn pub-type="epub">1559-064X</issn></journal-meta><article-meta><article-id pub-id-type="pmid">31164703</article-id><article-id pub-id-type="pmc">6891140</article-id><article-id pub-id-type="doi">10.1038/s41370-019-0146-1</article-id><article-id pub-id-type="manuscript">NIHMS1529902</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Estimating Personal Exposures from a Multi-Hazard Sensor
Network</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Zuidema</surname><given-names>Christopher</given-names></name><xref ref-type="aff" rid="A1">1</xref><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Stebounova</surname><given-names>Larissa V.</given-names></name><xref ref-type="aff" rid="A3">3</xref></contrib><contrib contrib-type="author"><name><surname>Sousan</surname><given-names>Sinan</given-names></name><xref ref-type="aff" rid="A3">3</xref><xref ref-type="aff" rid="A4">4</xref><xref ref-type="aff" rid="A5">5</xref></contrib><contrib contrib-type="author"><name><surname>Gray</surname><given-names>Alyson</given-names></name><xref ref-type="aff" rid="A3">3</xref></contrib><contrib contrib-type="author"><name><surname>Stroh</surname><given-names>Oliver</given-names></name><xref ref-type="aff" rid="A6">6</xref></contrib><contrib contrib-type="author"><name><surname>Thomas</surname><given-names>Geb</given-names></name><xref ref-type="aff" rid="A6">6</xref></contrib><contrib contrib-type="author"><name><surname>Peters</surname><given-names>Thomas</given-names></name><xref ref-type="aff" rid="A3">3</xref></contrib><contrib contrib-type="author"><name><surname>Koehler</surname><given-names>Kirsten</given-names></name><xref rid="CR1" ref-type="corresp">*</xref><xref ref-type="aff" rid="A1">1</xref></contrib></contrib-group><aff id="A1"><label>1</label>Department of Environmental Health and Engineering, Johns
Hopkins Bloomberg School of Public Health, Baltimore, MD</aff><aff id="A2"><label>2</label>Department of Occupational and Environmental Health
Sciences, University of Washington School of Public Health</aff><aff id="A3"><label>3</label>Department of Occupational and Environmental Health,
University of Iowa, Iowa City, IA</aff><aff id="A4"><label>4</label>Department of Public Health, East Carolina University,
Greenville, NC</aff><aff id="A5"><label>5</label>North Carolina Agro medicine Institute, Greenville,
NC</aff><aff id="A6"><label>6</label>Department of Industrial and Systems Engineering,
University of Iowa, Iowa City, IA</aff><author-notes><corresp id="CR1"><label>*</label>Corresponding author: Kirsten Koehler, PhD,
Department of Environmental Health and Engineering, Johns Hopkins Bloomberg
School of Public Health, 615 N. Wolfe St. Room E6632, Baltimore, MD 21205,
Phone: (410) 955-7706, Fax: (410) 955-0617,
<email>kirsten.koehler@jhu.edu</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>24</day><month>5</month><year>2019</year></pub-date><pub-date pub-type="epub"><day>04</day><month>6</month><year>2019</year></pub-date><pub-date pub-type="ppub"><month>11</month><year>2020</year></pub-date><pub-date pub-type="pmc-release"><day>05</day><month>12</month><year>2019</year></pub-date><volume>30</volume><issue>6</issue><fpage>1013</fpage><lpage>1022</lpage><!--elocation-id from pubmed: 10.1038/s41370-019-0146-1--><permissions><license xlink:href="http://www.nature.com/authors/editorial_policies/license.html#terms"><license-p>Users may view, print, copy, and download text and data-mine the content in such documents, for the purposes of academic research, subject always to the full Conditions of use:<ext-link ext-link-type="uri" xlink:href="http://www.nature.com/authors/editorial_policies/license.html#terms">http://www.nature.com/authors/editorial_policies/license.html#terms</ext-link></license-p></license></permissions><abstract id="ABS1"><p id="P1">Occupational exposure assessment is almost exclusively accomplished with
personal sampling. However, personal sampling can be burdensome and suffers from
low sample sizes, resulting in inadequately characterized workplace exposures.
Sensor networks offer the opportunity to measure occupational hazards with a
high degree of spatiotemporal resolution. Here, we demonstrate an approach to
estimate personal exposure to respirable particulate matter (PM), carbon
monoxide (CO), ozone (O<sub>3</sub>), and noise using hazard data from a sensor
network. We simulated stationary and mobile employees that work at the study
site, a heavy-vehicle manufacturing facility. Network-derived exposure estimates
compared favorably to measurements taken with a suite of personal direct-reading
instruments (DRIs) deployed to mimic personal sampling but varied by hazard and
type of employee. The root mean square error (RMSE) between network-derived
exposure estimates and personal DRI measurements for mobile employees was 0.15
mg/m<sup>3</sup>, 1 ppm, 82 ppb, and 3 dBA for PM, CO, O<sub>3</sub>, and
noise, respectively. Pearson correlation between network-derived exposure
estimates and DRI measurements ranged from 0.39 (noise for mobile employees) to
0.75 (noise for stationary employees). Despite the error observed estimating
personal exposure to occupational hazards it holds promise as an additional tool
to be used with traditional personal sampling due to the ability to frequently
and easily collect exposure information on many employees.</p></abstract><kwd-group><kwd>low-cost sensors</kwd><kwd>sensor networks</kwd><kwd>personal sampling</kwd><kwd>area sampling</kwd><kwd>exposure assessment</kwd></kwd-group></article-meta></front><body><sec id="S1"><title>INTRODUCTION</title><p id="P2">Occupational environments, especially heavy industry, often have complex
hazardous exposures resulting from manufacturing processes including cutting metal
stock, welding, grinding, machining, and abrasive blasting. Exposures resulting from
these processes include particulate matter (PM); gases such carbon monoxide (CO),
oxides of nitrogen (NO<sub>x</sub>), and ozone (O<sub>3</sub>); metals including
lead, nickel, zinc, manganese, iron oxides, copper, cadmium and chromium; physical
hazards such as noise, heat, electrical and vibration; and radiological including
visible and ultraviolet frequencies of light.<sup><xref rid="R1" ref-type="bibr">1</xref></sup> To assess compliance with occupational exposure limits to
workplace hazards, employers have historically performed exposure monitoring,
typically by personal sampling on individuals suspected to have high
exposure.<sup><xref rid="R2" ref-type="bibr">2</xref></sup> However,
personal sampling can have drawbacks such as high expense and burden to employees
and generally suffers from a low number of samples taken.<sup><xref rid="R3" ref-type="bibr">3</xref></sup> In most cases, fewer than six samples at an
industrial facility are used to judge if employees may be over-exposed or workplaces
are in compliance with regulatory permissible exposure limits,<sup><xref rid="R4" ref-type="bibr">4</xref></sup> and many rely on just one
measurement.<sup><xref rid="R5" ref-type="bibr">5</xref></sup> This
situation results in inadequately characterized workplace exposures and occupational
risks that may be higher than compliance testing indicates.<sup><xref rid="R3" ref-type="bibr">3</xref></sup></p><p id="P3">In light of this problem, the National Institute for Occupational Safety and
Health (NIOSH) has called for &#x0201c;comprehensive exposure assessment,&#x0201d;
where risks from all hazards for all days and all workers are considered.<sup><xref rid="R6" ref-type="bibr">6</xref></sup> Furthermore, cost-efficient
occupational exposure assessment, where both economics and statistical efficiency
(e.g. number of subjects, sample size and measurement error) are considered, is also
needed.<sup><xref rid="R7" ref-type="bibr">7</xref></sup> Low-cost sensors
could potentially fill this need and have recently attracted the attention of
environmental health scientists seeking to measure air pollution with a high degree
of temporal and spatial resolution, for example compared to commonly used daily
averages.<sup><xref rid="R8" ref-type="bibr">8</xref>&#x02013;<xref rid="R12" ref-type="bibr">12</xref></sup> Advances in open software toolkits and
microprocessor platforms have facilitated the development of customized wireless
sensor networks, and there is a growing number of examples in the
literature.<sup><xref rid="R13" ref-type="bibr">13</xref>&#x02013;<xref rid="R22" ref-type="bibr">22</xref></sup> Data from sensor networks may be
used to create hazard maps,<sup><xref rid="R23" ref-type="bibr">23</xref>&#x02013;<xref rid="R31" ref-type="bibr">31</xref></sup> which
visually communicate risk,<sup><xref rid="R32" ref-type="bibr">32</xref></sup>
identify hazard sources,<sup><xref rid="R24" ref-type="bibr">24</xref>, <xref rid="R27" ref-type="bibr">27</xref></sup> characterize the distribution of
hazards in a facility or the environment,<sup><xref rid="R26" ref-type="bibr">26</xref>, <xref rid="R27" ref-type="bibr">27</xref>, <xref rid="R31" ref-type="bibr">31</xref></sup> and inform hazard control
strategies.<sup><xref rid="R24" ref-type="bibr">24</xref></sup></p><p id="P4">We have previously developed a multi-hazard sensor network constructed with
low-cost sensors for PM, CO, oxidizing gases (O<sub>3</sub>+ NO<sub>2</sub>) and
noise.<sup><xref rid="R33" ref-type="bibr">33</xref></sup> An industrial
hygienist identified hazards at the study site, a heavy-vehicle manufacturing
facility, and those of greatest occupational health importance were chosen for
inclusion our sensor network. PM has well-characterized associations with
cardiopulmonary and respiratory diseases, lung cancer, inflammation, oxidative
stress, pulmonary infection, and lung function.<sup><xref rid="R34" ref-type="bibr">34</xref>&#x02013;<xref rid="R37" ref-type="bibr">37</xref></sup> The health
effects of occupationally relevant CO concentrations include headache, dizziness,
weakness, nausea and confusion.<sup><xref rid="R38" ref-type="bibr">38</xref></sup>
The inhalation of O<sub>3</sub> causes inflammation, reduced lung function, DNA
damage and increased symptoms and development of asthma.<sup><xref rid="R39" ref-type="bibr">39</xref>&#x02013;<xref rid="R42" ref-type="bibr">42</xref></sup> Occupational noise exposure induces hearing impairment,
hypertension and annoyance.<sup><xref rid="R43" ref-type="bibr">43</xref></sup>
Additionally, there is limited evidence that noise in the workplace is associated
with biochemical and immune effects, and impacts absentee rate and
performance.<sup><xref rid="R43" ref-type="bibr">43</xref></sup></p><p id="P5">In previous work, we have described the long-term deployment of our
multi-hazard sensor network capable of mapping PM, CO, oxidizing gases and noise at
the study site with a high degree of spatial and temporal resolution.<sup><xref rid="R44" ref-type="bibr">44</xref></sup> In the current study we
demonstrate that hazard mapping data from a multi-hazard sensor network, when
combined with an individual&#x02019;s location information, can be used to
quantitatively estimate personal exposure to multiple occupational hazards
simultaneously. We compare the network-derived exposure estimates to personal
measurements collected from high-quality, personal direct-reading instruments that
are commonly used in industrial hygiene practice.</p></sec><sec id="S2"><title>MATERIALS AND METHODS</title><sec id="S3"><title>Sensor Network</title><p id="P6">We designed and constructed multi-hazard monitors, the sensors for which
are summarized in <xref rid="SD1" ref-type="supplementary-material">Table
S1</xref>. Each monitor, or &#x0201c;node&#x0201d; of the sensor network was
equipped with sensors to measure PM (GP2Y1010AU0F, Sharp Electronics, Osaka,
Japan); oxidizing gases (OX-B431, Alpha sense Ltd., Essex UK; responsive to both
O<sub>3</sub> and NO<sub>2</sub>); CO (CO-B4, Alpha sense Ltd., Essex UK);
sound pressure level (SPL)<sup><xref rid="R45" ref-type="bibr">45</xref></sup>;
and temperature and relative humidity (AM2302, Ada fruit, New York,
NY).<sup><xref rid="R33" ref-type="bibr">33</xref></sup> The 40-node
network was installed for approximately eight months within 74 900 m<sup>2</sup>
of a +185 800 m<sup>2</sup> manufacturing facility that produces heavy vehicles
for construction and forestry. The nodes of the network were deployed in a
spatially optimized pattern to capture maximum spatial variability,<sup><xref rid="R46" ref-type="bibr">46</xref></sup> and measurements from each
monitor were transmitted wirelessly to a central database approximately every
five minutes, permitting the hazard variability to be characterized with a high
degree of spatial and temporal resolution.</p><p id="P7">We applied calibration curves developed in the laboratory for the CO and
oxidizing gas sensors from a sample of three sensors of each type.<sup><xref rid="R47" ref-type="bibr">47</xref></sup> These calibration curves were
then applied to all sensors of that type in the monitor network for the duration
of the sensor network deployment. The noise sensor used in the network was
custom-made for this project.<sup><xref rid="R45" ref-type="bibr">45</xref></sup> Briefly, each of the sensors were calibrated over a range
of 65 to 95 dB with an acceptance criterion of &#x000b1;2 dB with respect to a
high quality direct-reading instrument (XL2, NTi Audio AG, Liechtenstein).</p><p id="P8">For PM, a field-derived slope was applied to each monitor based on values
obtained at a calibration site with a direct-reading instrument (pDR-1000,
Thermo Scientific, Franklin, MA).<sup><xref rid="R44" ref-type="bibr">44</xref></sup> Because neither the pDR-1000 nor the PM sensors are size
selective, the average of five respirable fraction filter samples taken over the
course of the sensor network deployment were used to gravimetrically correct the
photometric PM concentrations (both the pDR-1000 and PM sensors). We took an
additional step to correct PM sensor drift over the eight-month deployment by
deriving sensor-specific weekly field calibration intercepts for each sensor. We
did this by setting the average millivolt (mV) value of each sensor between
00:00 and 02:00 every Sunday night when PM concentrations were lowest, equal to
the sensor LOD (0.026 mg/m<sup>3</sup>).<sup><xref rid="R44" ref-type="bibr">44</xref></sup> The PM sensors in our network are affected by relative
humidity (RH), but the impact on performance up to 67% RH is small,<sup><xref rid="R48" ref-type="bibr">48</xref></sup> and since RH in this study was
typically well below that, we made no RH correction (%RH mean &#x000b1; standard
deviation: 26 &#x000b1; 10%). The effect of temperature on the PM sensor was
negligible.<sup><xref rid="R48" ref-type="bibr">48</xref></sup></p><p id="P9">For each of the sensor types in the network, we imputed all sensor
measurements that were below the sensor limit of detection (LOD) with a value of
the LOD divided by the square root of two (LODs: PM<sup><xref rid="R49" ref-type="bibr">49</xref></sup> = 0.026 mg/m<sup>3</sup>; CO = 10 ppb;
OX-B431<sup><xref rid="R50" ref-type="bibr">50</xref></sup> = 4 ppb;
noise<sup><xref rid="R45" ref-type="bibr">45</xref></sup> = 65 dBA). We
have previously reported on the spatial and temporal variability of hazards,
sensor precision, and measurement accuracy in the facility.<sup><xref rid="R44" ref-type="bibr">44</xref></sup></p></sec><sec id="S4"><title>Worker Simulation and Personal DRIs</title><p id="P10">On five occasions in August 2017, December 2017, and March 2018 we
simulated two types of workers. The first type of worker was one that was highly
mobile and traveled throughout the facility at a walking or slow biking/driving
pace, such as supervisors, mechanics, employees that move small parts between
workstations, and maintenance workers. For the first type of simulated worker,
personal DRIs were worn by study staff, as a worker would for traditional
personal sampling. Hereafter we refer to this simulated employee type as the
&#x0201c;mobile&#x0201d; routine. For the mobile sampling routines, study staff
kept a detailed log of their position as they moved throughout the facility
according to an established coordinate system, marked by regularly spaced
structural I-beams. The second type of worker was one that remained in a
relatively small geographic space (within an area &#x02264; 12 &#x000d7; 18 m) to
perform their work duties, such as a welder or machine operator. For this type
of simulated worker, personal DRIs were deployed at an employee workstation for
the duration of the simulated work shift and were not moved. Hereafter we refer
to this simulated employee type as the &#x0201c;stationary&#x0201d; routine. We
simulated a total of 22 work shifts (5 mobile and 17 stationary) during times of
typical production (weekdays, 6:00&#x02013;16:00). The personal DRIs were as
follows: respirable PM, personal Data RAM 1500 configured for respirable dust
sampling (&#x02018;pDR-1500,&#x02019; Thermo Scientific, Franklin, MA); CO, Easy
Log CO-300 (Lascar Electronics Ltd., Erie, PA); O<sub>3</sub>, Personal Ozone
Monitor (&#x02018;POM,&#x02019; 2BTechnologies, Boulder, CO); and noise, Spark
703+ (Larson-Davis Inc., Depew, NY). The personal DRIs used in this study for
each hazard are shown in <xref rid="SD1" ref-type="supplementary-material">Table
S1</xref> alongside the low-cost sensors in the sensor network. These DRIs
were chosen for personal measurements because they were representative of
typical instruments commonly used for occupational exposure assessment by
industrial hygienists and health and safety professionals.</p></sec><sec id="S5"><title>Network-Derived Exposure Estimates</title><p id="P11">A schematic representation of our method for computing sensor
network-derived exposure estimates is depicted in <xref rid="F1" ref-type="fig">Figure 1</xref>, where two pieces of information are integrated: 1) the
location of the simulated worker and 2) the hazard intensity at the position of
interest. The blue line indicates the route traveled by a simulated employee and
the blue &#x0201c;X&#x0201d; indicates the location of the employee at a given
time (t<sub>0</sub>, t<sub>1</sub>&#x02026; t<sub>i</sub>). Hazard intensity is
represented by hazard maps, and for each time of interest, t<sub>i</sub>, we
estimated the hazard intensity, at the location of interest, (x,y). We used an
inverse distance weighting (IDW) scheme to interpolate hazard intensity at
unmeasured locations, which are displayed as a hazard maps for each five- minute
period. Interpolating hazard intensity with IDW is physically plausible and
computationally practical. We chose inverse distance squared weighting because
it is supported by previous studies.<sup><xref rid="R32" ref-type="bibr">32</xref></sup> Location and time information for the mobile sampling
routine was recorded at every movement of study staff as they traveled
throughout the facility, generally following a pattern of walking for one to two
minutes (covering approximately 24&#x02013;41 m), remaining stationary for five
to fifteen minutes and walking again to the next location. Location for the
stationary routine was taken as the coordinate where the suite of personal DRIs
was deployed and did not change for the duration of the sampling period. Because
the sensor network recorded hazard measurements every five minutes, we
constructed hazard estimates at five-minute intervals also (e.g. t<sub>0</sub> =
7:00, t<sub>1</sub> = 7:05&#x02026; t<sub>i</sub> = 7:00 + 0:05&#x02219;i). Data
analysis was performed with MATLAB R2017a (Natick, MA), with exception of
descriptive noise calculations which were carried out in R 3.5.2 (Vienna,
Austria) with the &#x02018;see wave&#x02019; package.<sup><xref rid="R51" ref-type="bibr">51</xref></sup></p></sec><sec id="S6"><title>Data Analysis &#x00026; Comparing Network-Derived Estimates and Personal DRI
Measurements</title><p id="P13">For each routine we paired five-minute network-derived exposure
estimates with five-minute personal DRI measurements and performed all analysis
on paired five-minute data. For each simulated work shift we plotted a time
series of the network-derived exposure estimates with the personal DRI
measurements time series to qualitatively assess their overall agreement and
correlation. We created &#x0201c;Bland-Altman&#x0201d; plots<sup><xref rid="R52" ref-type="bibr">52</xref></sup> displaying the difference versus the
mean of network-derived exposure estimates and measurements taken with personal
DRIs to compare their agreement. These plots show the mean difference between
the network-derived exposure estimates and the personal DRI measurements and the
limits of agreement (the mean difference &#x000b1; 2&#x003c3;). For differences
that are normally distributed, 95% of the data will fall within the limits of
agreement.</p><p id="P14">We pooled the five-minute pairs of network-derived exposure estimates
and personal DRI measurements by simulated employee type (mobile or stationary)
and by the month collected (August 2017, December 2017, March 2018, and August,
December and March combined) for the following summary statistics: number of
paired network-derived exposure estimates and personal DRI measurements, root
mean squared error (RMSE), Pearson correlation, and relative agreement
computations. We performed a regression-based comparison between network-
derived exposure estimates and personal DRI measurements and calculated the RMSE
and Pearson correlation coefficient. We tabulated a relative measure of
agreement between network- derived estimates and personal DRI measurements by
calculating the fraction of network-derived exposure estimates that were within
(&#x000b1;) 10, 25, 50 and 100% of the personal DRI measurements.</p></sec></sec><sec id="S7"><title>RESULTS</title><p id="P15">Examples of time series for the August 2017 sampling period comparing
network-derived mobile exposure estimates to personal DRI measurements are shown in
<xref rid="F2" ref-type="fig">Figure 2</xref>. The results of all personal DRI
measurements and network-derived exposure estimates are summarized in <xref rid="T1" ref-type="table">Table 1</xref> (mobile routine) and <xref rid="SD1" ref-type="supplementary-material">Table S2</xref> (stationary routine). We
collected data for one mobile and three stationary routines on one day in August
2017, two mobile and six stationary routines over two days in December 2017, and two
mobile eight stationary routines over two days in March 2018. The number of 5-min
pairs of network-derived exposure estimates and personal DRI measurements, N, ranged
between 55 (all hazards, August 2017) and 169 (CO, March 2018). The number of
five-minute pairs differed between hazards and time periods due to instrument
allocation, run times and equipment failures. For example, in December 2017 for two
mobile routines of approximately six hours each we collected a total of 156 pairs of
five-minute network-derived exposure estimates and personal DRI measurements for
both CO and noise. In comparison, we collected 153 pairs for PM due to a difference
in run-time and only 91 pairs for O<sub>3</sub>, due to personal DRI failure.</p><p id="P16">The geometric mean (GM) and arithmetic means (AM) of PM, CO, O<sub>3</sub>
and noise measured by the personal DRIs varied between each of the sampling periods
(August 2017 vs. December 2017 vs. March 2018), are shown in <xref rid="T1" ref-type="table">Table 1</xref> (mobile routine) and <xref rid="SD1" ref-type="supplementary-material">Table S2</xref> (stationary routine). Mean
hazard intensities generally reflected manufacturing activity in the facility,
specifically, production in the facility during the December 2017 period was low due
to the upcoming holiday shutdown, and comparatively higher for the March 2018
period. For example, the lowest PM concentrations were observed for both mobile and
stationary personal DRI measurements in December 2017 (GM PM concentrations: mobile
= 0.30 mg/m<sup>3</sup>; stationary = 0.20 mg/m<sup>3</sup>) and were highest in
March 2018 (GM PM concentrations: mobile = 0.48 mg/m<sup>3</sup>; stationary = 0.58
mg/m<sup>3</sup>). Other hazards displayed similar patterns but differences
between sampling periods were not as notable as those observed for PM. None of the
5-min personal DRI measurements were below the instrument&#x02019;s LOD for PM, and
noise. For CO 2%, and for O<sub>3</sub>, 0.3% of DRI measurements were below the
instrument&#x02019;s LOD.</p><p id="P17">Comparisons of mobile routine personal DRI measurements and network-derived
exposure estimates are shown in <xref rid="T1" ref-type="table">Table 1</xref>. In
the mobile routine for the combined time period the RMSEs between network-derived
estimates and DRI measurements were 0.15 mg/m<sup>3</sup>, 1 ppm, 27 ppb, and 3 dBA
for PM, CO, O<sub>3</sub> and noise, respectively. For PM, CO, and noise there was
little variation in the RMSE between August 2017, December 2017 and March 2018. We
observed greater variability in the RMSE for O<sub>3</sub>, which increased over
time, from 11 ppb in August 2017 to 31 ppb in March 2018 &#x02013; likely related to
the generally higher O<sub>3</sub> concentrations observed in March 2018 which were
associated with larger differences between network-derived exposure estimates and
personal DRI measurements. The correlation observed between the network- derived
exposure estimates and their respective personal DRIs for each hazard also varied
for the mobile routine. The combined Pearson correlation was highest for CO (r =
0.66), whereas the lowest was for noise (r = 0.39). In the mobile routine, as with
the stationary routine, the fraction of network-derived exposure estimates within a
given percentage of the personal DRI measurements was highest for noise. For
example, 0.96 of the combined noise estimates were within 10% of the personal DRI,
compared to 0.24 for CO, 0.16 for PM and 0.07 for O<sub>3</sub>. Unfortunately, due
to equipment failure in the March 2018 sampling period, no mobile noise personal DRI
measurements were collected.</p><p id="P18">The Bland-Altman plots between network-derived exposure estimates and
personal DRI measurements for the mobile routine are displayed in <xref rid="F3" ref-type="fig">Figure 3</xref>. For PM, CO, O<sub>3</sub>, and noise the mean
difference (limits of agreement) between the network-derived exposure estimates and
the personal DRI measurements was equal to 0.00 (&#x02212;0.39, 0.39)
mg/m<sup>3</sup>, 0 (&#x02212;4, 4) ppm, 36 (&#x02212;86, 158) ppb, and &#x02212;3
(&#x02212;9, 4) dBA, respectively. Differences between network-derived exposure
estimates and personal DRI measurements were centered and evenly distributed near
zero for PM and CO. For O<sub>3</sub>, at higher concentrations network-derived
exposure estimates were increasingly negatively biased compared to personal DRI
measurements. For noise, network-derived exposure estimates were generally lower
than personal DRI measurements across the range observed.</p><p id="P19">Results for the stationary routine are presented in the <xref rid="SD1" ref-type="supplementary-material">Supporting Information</xref> (<xref rid="SD1" ref-type="supplementary-material">Table S2</xref> and <xref rid="SD1" ref-type="supplementary-material">Figure S1</xref>). Generally, we observed
similarity between the stationary and mobile routines with respect to the fraction
of network-derived exposure estimates that fell within 10, 25, 50, and 100% of their
corresponding personal DRI measurements. Of all hazards, the combined network-
derived exposure estimates for noise had the largest fraction of estimates within
the smallest percentage of the personal DRI measurements for both the mobile and
stationary routines, where 0.99 &#x02013; 1.00 of network-derived exposure estimates
were within 10% of personal DRI measurements. In contrast, the hazard with the
lowest fraction of network-derived exposure estimates within 100% of personal DRI
measurements was O<sub>3</sub> for both routines, with only 0.45 for the combined
stationary routine and 0.46 for the combined mobile routine.</p><p id="P20">The Pearson correlation between network-derived exposure estimates and
personal DRI measurements varied by hazard, mobile versus stationary routine, and
time period. Pearson correlation varied by hazard in the combined time periods of
the mobile routines, it was highest for CO (r = 0.66) and lowest for noise (r =
0.39). Variability in correlation by routine was observed with noise, which had the
biggest difference between the stationary routine (r = 0.75) and the mobile routine
(0.39). An example of variability in correlation by sampling period, was observed
for the mobile O<sub>3</sub> routine &#x02013; in December 2017, the Pearson
correlation coefficient was equal to 0.05, compared to August 2017 where it was
equal to 0.63. These differences in correlation between hazards and stationary
versus mobile routine could have been affected by the by the variability of the
hazards during each study period and routine. For example, according to the personal
DRIs, the combined GM (geometric standard deviation, GSD) for CO was equal to 3 (4)
ppm for the mobile routine and 5 (3) ppm for the stationary routine; while noise had
a combined mean (standard deviation) equal to 83 (3) dBA for the mobile routine and
81 (10) dBA for the stationary routine. The larger the range of the hazard intensity
and the more evenly data are distributed across that range may result in higher
correlation coefficients observed for some hazards and periods of time than
others.</p></sec><sec id="S8"><title>DISCUSSION</title><p id="P21">The success of our approach estimating personal exposure highly depends on
the accuracy of the underlying hazard measurements of the sensor network. We have
previously reported on the accuracy of this sensor network&#x02019;s measurements by
conducting experiments where each monitor was collocated with personal DRIs for one
to five minutes.<sup><xref rid="R44" ref-type="bibr">44</xref></sup> In that study
over a range of hazard intensities, we observed the magnitudes of the median percent
bias between network monitors and DRIs were equal to 27%, 11%, 45% and 1%, for PM,
CO, O<sub>3</sub> and noise respectively. In the same study, we observed higher
levels of bias at lower hazard intensity &#x02013; as high as 163% and 156% for PM
and O<sub>3</sub>, respectively.</p><p id="P22">While the sources of measurement error from low-cost sensors differ, they
can often be attributed to issues of sensitivity and specificity, in part due to
sensor drift or degradation over time or responsiveness to non-target species. The
PM sensor in our network showed evidence of decreasing sensitivity over time due to
sensor loading or fouling.<sup><xref rid="R33" ref-type="bibr">33</xref></sup> To
reduce the effects of this drift on PM concentration estimates, we developed a
procedure to correct the sensors weekly. In addition, the PM sensor in our network
was not size selective, and there is evidence the sensors produce signals that vary
with different PM composition or size distribution.<sup><xref rid="R53" ref-type="bibr">53</xref></sup> Future work to improve the accuracy of
estimates from the sensor network include accounting for aerosol size and
composition effects on the sensor response and additional in-field calibrations of
all sensors. Sensor technology is continuously improving and emerging sensors may
measure PM concentrations with lower bias in the future.</p><p id="P23">Our network was constructed with an oxidative gas sensor to estimate
O<sub>3</sub> concentrations. In addition to O<sub>3</sub> the sensor also
responds to NO<sub>2</sub> without discrimination,<sup><xref rid="R54" ref-type="bibr">54</xref>, <xref rid="R55" ref-type="bibr">55</xref></sup>complicating the estimation of O<sub>3</sub> in environments where
NO<sub>2</sub> is also present. Future work may be able to incorporate the
manufacturer&#x02019;s proposed method to pair an oxidizing gas sensor with and
NO<sub>2</sub>-specific sensor to improve the accuracy of O<sub>3</sub>
measurements.<sup><xref rid="R54" ref-type="bibr">54</xref></sup> Another
source of error in this study is a ceiling observed on the CO sensor as configured
in our network at approximately 12 ppm CO,<sup><xref rid="R47" ref-type="bibr">47</xref></sup> resulting from the optimization of the CO sensor signal for
concentrations anticipated at the study site.<sup><xref rid="R33" ref-type="bibr">33</xref></sup> Because of this, the CO sensors are not sensitive to
increasing CO concentrations above 12 ppm (totaling approximately 1% of all personal
CO DRI measurements in this study). These errors in measurement translate to
potential errors in estimating personal exposure. In contrast, the noise sensor,
which was designed specifically for this sensor-network,<sup><xref rid="R45" ref-type="bibr">45</xref></sup> did not show evidence of signal drift or
degradation over time, and provided network- derived estimates agreeing most closely
with the personal DRI measurements. However, despite the high agreement of the noise
exposure estimates, in some sampling periods, the Pearson correlation coefficient
was low (r = 0.23 for the August 2017 mobile routine), demonstrating that
correlation between a sensor and personal DRI may not be the best measure of sensor
performance.</p><p id="P24">Our approach of estimating exposure requires utilizing hazard measurements
from a low-cost sensor network with high temporal and spatial resolution. Despite
these challenging requirements, in this study we demonstrate it is feasible. The
sensor network time resolution was five minutes; accordingly, we used a five-minute
averaging time for the personal DRIs for comparison. Although a five-minute time
resolution is high compared to shift-long time- weighted averages (TWAs), our
approach was incapable of finer time resolution and may fail to accurately capture
the peaks of brief high exposure events, especially for hazards that decay quickly,
for example, impact or impulse noise. Another example is O<sub>3</sub>, which is
highly reactive and degrades quickly after it is produced. Limitations in temporal
resolution especially affect the estimates for employees that move through the
facility at a rapid pace potentially covering large distances in the facility in
five minutes, such as materials handlers or forklift operators. We were unable to
simulate these types of rapidly moving employees in this study. To estimate hazard
intensity at locations where nodes of the sensor network were not located, we
interpolated hazard intensity using an IDW scheme. While this spatial interpolation
undoubtedly introduced some degree of error, the nodes of our network were spatially
dense, with the maximum distance to the nearest monitor equal to 40 m (135 ft),
helping to avoid errors related to spatial interpolation. Still, the potential to
mischaracterize the spatial variability of hazards, especially those that decrease
rapidly from their sources remains. We examined the impact of the distance to the
nearest sensor network node and did not observe a relationship with respect to the
bias of network-derived exposure estimates and personal DRI measurements.</p><p id="P25">In this study for simulated mobile employees, location information was
supplied by study staff keeping a location diary during the sampling period.
Although this was necessary to demonstrate our approach for generating
network-derived exposure estimates, it is not practical for employees or employers,
and automated indoor positioning systems would reduce the burden for this type of
exposure assessment. While previous exposure assessment studies have used Global
Positioning Systems (GPS) successfully,<sup><xref rid="R56" ref-type="bibr">56</xref>, <xref rid="R57" ref-type="bibr">57</xref></sup> they
unfortunately generally perform poorly indoors due to interference from building
roofs and a lack of &#x0201c;line-of-sight&#x0201d; to the satellites.<sup><xref rid="R58" ref-type="bibr">58</xref></sup> Therefore, for indoor/occupational
settings, technologies specifically capable of indoor localization are necessary.
These indoor positioning systems include radio frequency identification (RFID),
wireless local area networks (WLAN), indoor GPS, and ultra-wide band radio
frequency,<sup><xref rid="R59" ref-type="bibr">59</xref>&#x02013;<xref rid="R61" ref-type="bibr">61</xref></sup> and have been investigated in
construction, manufacturing, warehouses, agriculture and healthcare
settings.<sup><xref rid="R60" ref-type="bibr">60</xref>, <xref rid="R62" ref-type="bibr">62</xref>&#x02013;<xref rid="R66" ref-type="bibr">66</xref></sup> Future work will focus on the use of indoor positioning systems
such as these to provide location information for generating exposure estimates
derived from a low-cost sensor network in an occupational setting.</p><p id="P26">Despite these challenges, this study had many novel features and strengths.
This is the first example of using a sensor network to estimate personal
occupational exposure that we are aware of. The sensor network achieved a high
degree of spatial resolution, reducing errors related to spatial interpolation. We
were able to estimate exposures at a relatively high temporal resolution, also an
advantage over shift-long TWAs. We maintained a high degree of accuracy for the
location information on simulated mobile employees with respect to both time and
space with position diaries. Consequently, the location information we used to
estimate personal exposures did not have errors that would have been inherent to
those provided by in an indoor positioning system. Our multi-hazard sensor network
was deployed at the study site continuously for nearly eight months. While we only
had access to the facility for five days over that period to conduct personal
sampling, we demonstrated the ability of our technique to potentially provide
personal exposure estimates for any employee whose position can be tracked over that
time. This kind of information on individual workers would be a vast improvement
over traditional personal sampling rates<sup><xref rid="R4" ref-type="bibr">4</xref>, <xref rid="R5" ref-type="bibr">5</xref></sup> with beneficial
implications for both occupational exposure assessment for occupational exposure
limit (OEL) compliance and epidemiological study.</p></sec><sec sec-type="supplementary-material" id="SM1"><title>Supplementary Material</title><supplementary-material content-type="local-data" id="SD1"><label>1</label><media xlink:href="NIHMS1529902-supplement-1.pdf" orientation="portrait" xlink:type="simple" id="d39e692" position="anchor"/></supplementary-material></sec></body><back><ack id="S9"><title>ACKNOWLEDGEMENTS</title><p id="P27">This project was funded through the National Institute for Occupational
Safety and Health (NIOSH) under grant number R01 OH 010533. C.Z. was supported by
the Johns Hopkins University Education and Research Center for Occupational Safety
and Health (ERC), which is funded by NIOSH under grant number T42 OH 008428, and the
University of Washington&#x02019;s Biostatistics, Epidemiology, and Bioinformatics
Training in Environmental Heath (BEBTEH), grant number T32ES015459, from the
National Institute for Environmental Health Science (NIEHS).</p></ack><fn-group><fn fn-type="COI-statement" id="FN1"><p id="P28">CONFLICT OF INTEREST</p><p id="P29">The authors declare no conflict of interest.</p></fn><fn id="FN2"><p id="P30"><bold>Supporting Information</bold>. Includes: discussion of stationary
routine results, a table of low-cost sensors and personal DRI instruments for
the hazards in this study, a table on the results comparing network- derived
exposure estimates to personal DRI measurements from the stationary routine, and
a figure displaying the Bland-Altman plots between personal exposure estimates
and personal DRI measurements from the stationary routine.</p></fn></fn-group><ref-list><title>REFERENCES</title><ref id="R1"><label>1.</label><mixed-citation publication-type="journal"><name><surname>Sferlazza</surname><given-names>SJ</given-names></name>, <name><surname>Beckett</surname><given-names>WS</given-names></name>. <article-title>The Respiratory Health of
Welders1&#x02013;3</article-title>. <source>Am Rev Respir Dis</source>.
<year>1991</year>;<volume>143</volume>:<fpage>1134</fpage>&#x02013;<lpage>48</lpage>.<pub-id pub-id-type="pmid">2024826</pub-id></mixed-citation></ref><ref id="R2"><label>2.</label><mixed-citation publication-type="journal"><name><surname>Rappaport</surname><given-names>SM</given-names></name>, <name><surname>Kupper</surname><given-names>LL</given-names></name>. <article-title>Quantitative exposure assessment: S</article-title>.
<source>Rappaport</source>; <year>2008</year>.</mixed-citation></ref><ref id="R3"><label>3.</label><mixed-citation publication-type="journal"><name><surname>Rappaport</surname><given-names>SM</given-names></name>. <article-title>The rules of the game: an analysis of OSHA&#x02019;s
enforcement strategy</article-title>. <source>Am J Ind Med</source>.
<year>1984</year>;<volume>6</volume>(<issue>4</issue>):<fpage>291</fpage>&#x02013;<lpage>303</lpage>.<pub-id pub-id-type="pmid">6496480</pub-id></mixed-citation></ref><ref id="R4"><label>4.</label><mixed-citation publication-type="other"><name><surname>Roick</surname><given-names>JC</given-names></name>, <name><surname>Norwood</surname><given-names>SK</given-names></name>, <name><surname>Hawkins</surname><given-names>NC</given-names></name>. <source>A strategy for occupational exposure assessment: AIHA</source>;
<year>1991</year>.</mixed-citation></ref><ref id="R5"><label>5.</label><mixed-citation publication-type="journal"><name><surname>Tornero-Velez</surname><given-names>R</given-names></name>, <name><surname>Symanski</surname><given-names>E</given-names></name>, <name><surname>Kromhout</surname><given-names>H</given-names></name>, <name><surname>Yu</surname><given-names>RC</given-names></name>, <name><surname>Rappaport</surname><given-names>SM</given-names></name>. <article-title>Compliance versus risk in assessing occupational
exposures</article-title>. <source>Risk Anal</source>.
<year>1997</year>;<volume>17</volume>(<issue>3</issue>):<fpage>279</fpage>&#x02013;<lpage>92</lpage>.<pub-id pub-id-type="pmid">9232013</pub-id></mixed-citation></ref><ref id="R6"><label>6.</label><mixed-citation publication-type="journal"><name><surname>Ramachandran</surname><given-names>G</given-names></name>. <article-title>Toward better exposure assessment strategies--the new
NIOSH initiative</article-title>. <source>The Annals of Occupational
Hygiene</source>.
<year>2008</year>;<volume>52</volume>(<issue>5</issue>):<fpage>297</fpage>&#x02013;<lpage>301</lpage>.<pub-id pub-id-type="pmid">18515849</pub-id></mixed-citation></ref><ref id="R7"><label>7.</label><mixed-citation publication-type="journal"><name><surname>Rezagholi</surname><given-names>M</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>. <article-title>Cost-efficient design of occupational exposure
assessment strategies--a review</article-title>. <source>The Annals of
Occupational Hygiene</source>.
<year>2010</year>;<volume>54</volume>(<issue>8</issue>):<fpage>858</fpage>&#x02013;<lpage>68</lpage>.<pub-id pub-id-type="pmid">20926518</pub-id></mixed-citation></ref><ref id="R8"><label>8.</label><mixed-citation publication-type="journal"><name><surname>Kumar</surname><given-names>P</given-names></name>, <name><surname>Morawska</surname><given-names>L</given-names></name>, <name><surname>Martani</surname><given-names>C</given-names></name>, <name><surname>Biskos</surname><given-names>G</given-names></name>, <name><surname>Neophytou</surname><given-names>M</given-names></name>, <name><surname>Di Sabatino</surname><given-names>S</given-names></name>, <etal/>
<article-title>The rise of low-cost sensing for managing air pollution in
cities</article-title>. <source>Environ Int</source>.
<year>2015</year>;<volume>75</volume>:<fpage>199</fpage>&#x02013;<lpage>205</lpage>.<pub-id pub-id-type="pmid">25483836</pub-id></mixed-citation></ref><ref id="R9"><label>9.</label><mixed-citation publication-type="journal"><name><surname>Snyder</surname><given-names>EG</given-names></name>, <name><surname>Watkins</surname><given-names>TH</given-names></name>, <name><surname>Solomon</surname><given-names>PA</given-names></name>, <name><surname>Thoma</surname><given-names>ED</given-names></name>, <name><surname>Williams</surname><given-names>RW</given-names></name>, <name><surname>Hagler</surname><given-names>GSW</given-names></name>, <etal/>
<article-title>The changing paradigm of air pollution
monitoring</article-title>. <source>Environ Sci Technol</source>.
<year>2013</year>;<volume>47</volume>(<issue>20</issue>):<fpage>11369</fpage>.<pub-id pub-id-type="pmid">23980922</pub-id></mixed-citation></ref><ref id="R10"><label>10.</label><mixed-citation publication-type="journal"><name><surname>Masson</surname><given-names>N</given-names></name>, <name><surname>Piedrahita</surname><given-names>R</given-names></name>, <name><surname>Hannigan</surname><given-names>M</given-names></name>. <article-title>Quantification method for electrolytic sensors in
long-term monitoring of ambient air quality</article-title>.
<source>Sensors</source>.
<year>2015</year>;<volume>15</volume>(<issue>10</issue>):<fpage>27283</fpage>&#x02013;<lpage>302</lpage>.<pub-id pub-id-type="pmid">26516860</pub-id></mixed-citation></ref><ref id="R11"><label>11.</label><mixed-citation publication-type="journal"><name><surname>Piedrahita</surname><given-names>R</given-names></name>, <name><surname>Xiang</surname><given-names>Y</given-names></name>, <name><surname>Masson</surname><given-names>N</given-names></name>, <name><surname>Ortega</surname><given-names>J</given-names></name>, <name><surname>Collier</surname><given-names>A</given-names></name>, <name><surname>Jiang</surname><given-names>Y</given-names></name>, <etal/>
<article-title>The next generation of low-cost personal air quality sensors for
quantitative exposure monitoring</article-title>. <source>Atmospheric
Measurement Techniques</source>.
<year>2014</year>;<volume>7</volume>(<issue>10</issue>):<fpage>3325</fpage>.</mixed-citation></ref><ref id="R12"><label>12.</label><mixed-citation publication-type="journal"><name><surname>Lewis</surname><given-names>AC</given-names></name>, <name><surname>Lee</surname><given-names>JD</given-names></name>, <name><surname>Edwards</surname><given-names>PM</given-names></name>, <name><surname>Shaw</surname><given-names>MD</given-names></name>, <name><surname>Evans</surname><given-names>MJ</given-names></name>, <name><surname>Moller</surname><given-names>SJ</given-names></name>, <etal/>
<article-title>Evaluating the performance of low cost chemical sensors for air
pollution research</article-title>. <source>Faraday Discuss</source>.
<year>2016</year>.</mixed-citation></ref><ref id="R13"><label>13.</label><mixed-citation publication-type="journal"><name><surname>Jiang</surname><given-names>Q</given-names></name>, <name><surname>Kresin</surname><given-names>F</given-names></name>, <name><surname>Bregt</surname><given-names>AK</given-names></name>, <name><surname>Kooistra</surname><given-names>L</given-names></name>, <name><surname>Pareschi</surname><given-names>E</given-names></name>, <name><surname>van Putten</surname><given-names>E</given-names></name>, <etal/>
<article-title>Citizen Sensing for Improved Urban Environmental
Monitoring</article-title>. <source>Journal of Sensors</source>.
<year>2016</year>;<volume>2016</volume>.</mixed-citation></ref><ref id="R14"><label>14.</label><mixed-citation publication-type="journal"><name><surname>English</surname><given-names>PB</given-names></name>, <name><surname>Olmedo</surname><given-names>L</given-names></name>, <name><surname>Bejarano</surname><given-names>E</given-names></name>, <name><surname>Lugo</surname><given-names>H</given-names></name>, <name><surname>Murillo</surname><given-names>E</given-names></name>, <name><surname>Seto</surname><given-names>E</given-names></name>, <etal/>
<article-title>The imperial county community air monitoring network: a model for
community-based environmental monitoring for public health
action</article-title>. <source>Environ Health Perspect</source>.
<year>2017</year>;<volume>125</volume>(<issue>7</issue>).</mixed-citation></ref><ref id="R15"><label>15.</label><mixed-citation publication-type="other"><name><surname>Hasenfratz</surname><given-names>D</given-names></name>, <name><surname>Saukh</surname><given-names>O</given-names></name>, <name><surname>Walser</surname><given-names>C</given-names></name>, <name><surname>Hueglin</surname><given-names>C</given-names></name>, <name><surname>Fierz</surname><given-names>M</given-names></name>, <name><surname>Arn</surname><given-names>T</given-names></name>, <etal/>
<source>Deriving high-resolution urban air pollution maps using mobile sensor
nodes, Pervasive and Mobile Computing, v.16
n</source>.<year>2015</year>.</mixed-citation></ref><ref id="R16"><label>16.</label><mixed-citation publication-type="journal"><name><surname>Heimann</surname><given-names>I</given-names></name>, <name><surname>Bright</surname><given-names>VB</given-names></name>, <name><surname>McLeod</surname><given-names>MW</given-names></name>, <name><surname>Mead</surname><given-names>MI</given-names></name>, <name><surname>Popoola</surname><given-names>OAM</given-names></name>, <name><surname>Stewart</surname><given-names>GB</given-names></name>, <etal/>
<article-title>Source attribution of air pollution by spatial scale separation
using high spatial density networks of low cost air quality
sensors</article-title>. <source>Atmos Environ</source>.
<year>2015</year>;<volume>113</volume>:<fpage>10</fpage>&#x02013;<lpage>9</lpage>.</mixed-citation></ref><ref id="R17"><label>17.</label><mixed-citation publication-type="journal"><name><surname>Kumar</surname><given-names>A</given-names></name>, <name><surname>Singh</surname><given-names>IP</given-names></name>, <name><surname>Sud</surname><given-names>SK</given-names></name>. <article-title>Energy efficient and low-cost indoor environment
monitoring system based on the IEEE 1451 standard</article-title>.
<source>IEEE Sensors Journal</source>.
<year>2011</year>;<volume>11</volume>(<issue>10</issue>):<fpage>2598</fpage>&#x02013;<lpage>610</lpage>.</mixed-citation></ref><ref id="R18"><label>18.</label><mixed-citation publication-type="other"><name><surname>Mead</surname><given-names>MI</given-names></name>, <name><surname>Popoola</surname><given-names>OAM</given-names></name>, <name><surname>Stewart</surname><given-names>GB</given-names></name>, <name><surname>Landshoff</surname><given-names>P</given-names></name>, <name><surname>Calleja</surname><given-names>M</given-names></name>, <name><surname>Hayes</surname><given-names>M</given-names></name>, <etal/>
<source>The use of electrochemical sensors for monitoring urban air quality in
low-cost, high-density networks</source>.</mixed-citation></ref><ref id="R19"><label>19.</label><mixed-citation publication-type="journal"><name><surname>Ikram</surname><given-names>J</given-names></name>, <name><surname>Tahir</surname><given-names>A</given-names></name>, <name><surname>Kazmi</surname><given-names>H</given-names></name>, <name><surname>Khan</surname><given-names>Z</given-names></name>, <name><surname>Javed</surname><given-names>R</given-names></name>, <name><surname>Masood</surname><given-names>U</given-names></name>. <article-title>View: implementing low cost air quality monitoring
solution for urban areas</article-title>. <source>Environmental Systems
Research</source>.
<year>2012</year>;<volume>1</volume>(<issue>1</issue>):<fpage>1</fpage>.</mixed-citation></ref><ref id="R20"><label>20.</label><mixed-citation publication-type="journal"><name><surname>Moltchanov</surname><given-names>S</given-names></name>, <name><surname>Levy</surname><given-names>I</given-names></name>, <name><surname>Etzion</surname><given-names>Y</given-names></name>, <name><surname>Lerner</surname><given-names>U</given-names></name>, <name><surname>Broday</surname><given-names>DM</given-names></name>, <name><surname>Fishbain</surname><given-names>B</given-names></name>. <article-title>On the feasibility of measuring urban air pollution by
wireless distributed sensor networks</article-title>. <source>Sci Total
Environ</source>.
<year>2015</year>;<volume>502</volume>:<fpage>537</fpage>&#x02013;<lpage>47</lpage>.<pub-id pub-id-type="pmid">25300018</pub-id></mixed-citation></ref><ref id="R21"><label>21.</label><mixed-citation publication-type="journal"><name><surname>Jiao</surname><given-names>W</given-names></name>, <name><surname>Hagler</surname><given-names>G</given-names></name>, <name><surname>Williams</surname><given-names>R</given-names></name>, <name><surname>Sharpe</surname><given-names>R</given-names></name>, <name><surname>Brown</surname><given-names>R</given-names></name>, <name><surname>Garver</surname><given-names>D</given-names></name>, <etal/>
<article-title>Community Air Sensor Network (CAIRSENSE) project: evaluation of
low-cost sensor performance in a suburban environment in the southeastern
United States</article-title>. <source>Atmos Meas Tech</source>.
<year>2016</year>;<volume>9</volume>(<issue>11</issue>):<fpage>5281</fpage>&#x02013;<lpage>92</lpage>.<pub-id pub-id-type="pmid">32802212</pub-id></mixed-citation></ref><ref id="R22"><label>22.</label><mixed-citation publication-type="journal"><name><surname>Gao</surname><given-names>M</given-names></name>, <name><surname>Cao</surname><given-names>J</given-names></name>, <name><surname>Seto</surname><given-names>E</given-names></name>. <article-title>A distributed network of low-cost continuous reading
sensors to measure spatiotemporal variations of PM2. 5 in Xi&#x02019;an,
China</article-title>. <source>Environmental pollution</source>.
<year>2015</year>;<volume>199</volume>:<fpage>56</fpage>&#x02013;<lpage>65</lpage>.<pub-id pub-id-type="pmid">25618367</pub-id></mixed-citation></ref><ref id="R23"><label>23.</label><mixed-citation publication-type="journal"><name><surname>Liu</surname><given-names>S</given-names></name>, <name><surname>Hammond</surname><given-names>SK</given-names></name>. <article-title>Mapping particulate matter at the body weld department
in an automobile assembly plant</article-title>. <source>J Occup Environ
Hyg</source>.
<year>2010</year>;<volume>7</volume>(<issue>10</issue>):<fpage>593</fpage>&#x02013;<lpage>604</lpage>.<pub-id pub-id-type="pmid">20803369</pub-id></mixed-citation></ref><ref id="R24"><label>24.</label><mixed-citation publication-type="journal"><name><surname>O&#x02019;Brien</surname><given-names>DM</given-names></name>. <article-title>Aerosol mapping of a facility with multiple cases of
hypersensitivity pneumonitis: demonstration of mist reduction and a possible
dose/response relationship</article-title>. <source>Appl Occup Environ
Hyg</source>.
<year>2003</year>;<volume>18</volume>(<issue>11</issue>):<fpage>947</fpage>&#x02013;<lpage>52</lpage>.<pub-id pub-id-type="pmid">14555448</pub-id></mixed-citation></ref><ref id="R25"><label>25.</label><mixed-citation publication-type="journal"><name><surname>Heitbrink</surname><given-names>WA</given-names></name>, <name><surname>Evans</surname><given-names>DE</given-names></name>, <name><surname>Peters</surname><given-names>TM</given-names></name>, <name><surname>Slavin</surname><given-names>TJ</given-names></name>. <article-title>Characterization and mapping of very fine particles in
an engine machining and assembly facility</article-title>. <source>J Occup
Environ Hyg</source>.
<year>2007</year>;<volume>4</volume>(<issue>5</issue>):<fpage>341</fpage>&#x02013;<lpage>51</lpage>.<pub-id pub-id-type="pmid">17454502</pub-id></mixed-citation></ref><ref id="R26"><label>26.</label><mixed-citation publication-type="journal"><name><surname>Peters</surname><given-names>TM</given-names></name>, <name><surname>Heitbrink</surname><given-names>WA</given-names></name>, <name><surname>Evans</surname><given-names>DE</given-names></name>, <name><surname>Slavin</surname><given-names>TJ</given-names></name>, <name><surname>Maynard</surname><given-names>AD</given-names></name>. <article-title>The mapping of fine and ultrafine particle
concentrations in an engine machining and assembly facility</article-title>.
<source>The Annals of Occupational Hygiene</source>.
<year>2006</year>;<volume>50</volume>(<issue>3</issue>):<fpage>249</fpage>&#x02013;<lpage>57</lpage>.<pub-id pub-id-type="pmid">16361396</pub-id></mixed-citation></ref><ref id="R27"><label>27.</label><mixed-citation publication-type="journal"><name><surname>Evans</surname><given-names>DE</given-names></name>, <name><surname>Heitbrink</surname><given-names>WA</given-names></name>, <name><surname>Slavin</surname><given-names>TJ</given-names></name>, <name><surname>Peters</surname><given-names>TM</given-names></name>. <article-title>Ultrafine and respirable particles in an automotive grey
iron foundry</article-title>. <source>The Annals of Occupational
Hygiene</source>.
<year>2008</year>;<volume>52</volume>(<issue>1</issue>):<fpage>9</fpage>&#x02013;<lpage>21</lpage>.<pub-id pub-id-type="pmid">18056626</pub-id></mixed-citation></ref><ref id="R28"><label>28.</label><mixed-citation publication-type="journal"><name><surname>Park</surname><given-names>JY</given-names></name>, <name><surname>Ramachandran</surname><given-names>G</given-names></name>, <name><surname>Raynor</surname><given-names>PC</given-names></name>, <name><surname>Olson</surname><given-names>GM</given-names><suffix>Jr</suffix></name>. <article-title>Determination of particle concentration rankings by
spatial mapping of particle surface area, number, and mass concentrations in
a restaurant and a die casting plant</article-title>. <source>J Occup
Environ Hyg</source>.
<year>2010</year>;<volume>7</volume>(<issue>8</issue>):<fpage>466</fpage>&#x02013;<lpage>76</lpage>.<pub-id pub-id-type="pmid">20526949</pub-id></mixed-citation></ref><ref id="R29"><label>29.</label><mixed-citation publication-type="journal"><name><surname>Vosburgh</surname><given-names>DJH</given-names></name>, <name><surname>Boysen</surname><given-names>DA</given-names></name>, <name><surname>Oleson</surname><given-names>JJ</given-names></name>, <name><surname>Peters</surname><given-names>TM</given-names></name>. <article-title>Airborne nanoparticle concentrations in the
manufacturing of polytetrafluoroethylene (PTFE) apparel</article-title>.
<source>J Occup Environ
Hyg</source>.<year>2011</year>;<volume>8</volume>(<issue>3</issue>):<fpage>139</fpage>&#x02013;<lpage>46</lpage>.<pub-id pub-id-type="pmid">21347955</pub-id></mixed-citation></ref><ref id="R30"><label>30.</label><mixed-citation publication-type="journal"><name><surname>Peters</surname><given-names>TM</given-names></name>, <name><surname>Anthony</surname><given-names>TR</given-names></name>, <name><surname>Taylor</surname><given-names>C</given-names></name>, <name><surname>Altmaier</surname><given-names>R</given-names></name>, <name><surname>Anderson</surname><given-names>K</given-names></name>, <name><surname>O&#x02019;Shaughnessy</surname><given-names>PT</given-names></name>. <article-title>Distribution of particle and gas concentrations in Swine
gestation confined animal feeding operations</article-title>. <source>The
Annals of Occupational Hygiene</source>.
<year>2012</year>;<volume>56</volume>(<issue>9</issue>):<fpage>1080</fpage>&#x02013;<lpage>90</lpage>.<pub-id pub-id-type="pmid">22904211</pub-id></mixed-citation></ref><ref id="R31"><label>31.</label><mixed-citation publication-type="journal"><name><surname>Ott</surname><given-names>DK</given-names></name>, <name><surname>Kumar</surname><given-names>N</given-names></name>, <name><surname>Peters</surname><given-names>TM</given-names></name>. <article-title>Passive sampling to capture spatial variability in PM
10&#x02013;2.5</article-title>. <source>Atmos Environ</source>.
<year>2008</year>;<volume>42</volume>(<issue>4</issue>):<fpage>746</fpage>&#x02013;<lpage>56</lpage>.</mixed-citation></ref><ref id="R32"><label>32.</label><mixed-citation publication-type="journal"><name><surname>Koehler</surname><given-names>KA</given-names></name>, <name><surname>Volckens</surname><given-names>J</given-names></name>. <article-title>Prospects and pitfalls of occupational hazard mapping:
&#x02018;between these lines there be dragons&#x02019;</article-title>.
<source>The Annals of Occupational Hygiene</source>.
<year>2011</year>;<volume>55</volume>(<issue>8</issue>):<fpage>829</fpage>&#x02013;<lpage>40</lpage>.<pub-id pub-id-type="pmid">21917819</pub-id></mixed-citation></ref><ref id="R33"><label>33.</label><mixed-citation publication-type="journal"><name><surname>Thomas</surname><given-names>G</given-names></name>, <name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Tatum</surname><given-names>M</given-names></name>, <name><surname>Liu</surname><given-names>X</given-names></name>, <name><surname>Zuidema</surname><given-names>C</given-names></name>, <name><surname>Fitzpatrick</surname><given-names>M</given-names></name>, <etal/>
<article-title>Low-Cost, Distributed Environmental Monitors for Factory Worker
Health</article-title>. <source>Sensors</source>.
<year>2018</year>;<volume>18</volume>(<issue>5</issue>):<fpage>1411</fpage>.</mixed-citation></ref><ref id="R34"><label>34.</label><mixed-citation publication-type="journal"><name><surname>Dockery</surname><given-names>DW</given-names></name>. <article-title>Epidemiologic study design for investigating respiratory
health effects of complex air pollution mixtures</article-title>.
<source>Environ Health Perspect</source>.
<year>1993</year>;<volume>101</volume>
<issue>Suppl
4</issue>:<fpage>187</fpage>&#x02013;<lpage>91</lpage>.<pub-id pub-id-type="pmid">8206028</pub-id></mixed-citation></ref><ref id="R35"><label>35.</label><mixed-citation publication-type="journal"><name><surname>Anderson</surname><given-names>JO</given-names></name>, <name><surname>Thundiyil</surname><given-names>JG</given-names></name>, <name><surname>Stolbach</surname><given-names>A</given-names></name>. <article-title>Clearing the air: a review of the effects of particulate
matter air pollution on human health</article-title>. <source>J Med
Toxicol</source>.
<year>2012</year>;<volume>8</volume>(<issue>2</issue>):<fpage>166</fpage>&#x02013;<lpage>75</lpage>.<pub-id pub-id-type="pmid">22194192</pub-id></mixed-citation></ref><ref id="R36"><label>36.</label><mixed-citation publication-type="journal"><name><surname>Pope</surname><given-names>CA</given-names></name>, <name><surname>Dockery</surname><given-names>DW</given-names></name>, <name><surname>Schwartz</surname><given-names>J</given-names></name>. <article-title>Review of epidemiological evidence of health effects of
particulate air pollution</article-title>. <source>Inhal Toxicol</source>.
<year>1995</year>;<volume>7</volume>(<issue>1</issue>):<fpage>1</fpage>&#x02013;<lpage>18</lpage>.</mixed-citation></ref><ref id="R37"><label>37.</label><mixed-citation publication-type="journal"><name><surname>Pope</surname><given-names>CA</given-names><suffix>III</suffix></name>, <name><surname>Dockery</surname><given-names>DW</given-names></name>. <article-title>Health effects of fine particulate air pollution: lines
that connect</article-title>. <source>J Air Waste Manag Assoc</source>.
<year>2006</year>;<volume>56</volume>(<issue>6</issue>):<fpage>709</fpage>&#x02013;<lpage>42</lpage>.<pub-id pub-id-type="pmid">16805397</pub-id></mixed-citation></ref><ref id="R38"><label>38.</label><mixed-citation publication-type="journal"><name><surname>Raub</surname><given-names>JA</given-names></name>, <name><surname>Mathieu-Nolf</surname><given-names>M</given-names></name>, <name><surname>Hampson</surname><given-names>NB</given-names></name>, <name><surname>Thom</surname><given-names>SR</given-names></name>. <article-title>Carbon monoxide poisoning&#x02014;a public health
perspective</article-title>. <source>Toxicology</source>.
<year>2000</year>;<volume>145</volume>(<issue>1</issue>):<fpage>1</fpage>&#x02013;<lpage>14</lpage>.<pub-id pub-id-type="pmid">10771127</pub-id></mixed-citation></ref><ref id="R39"><label>39.</label><mixed-citation publication-type="journal"><name><surname>Bornholdt</surname><given-names>J</given-names></name>, <name><surname>Dybdahl</surname><given-names>M</given-names></name>, <name><surname>Vogel</surname><given-names>U</given-names></name>, <name><surname>Hansen</surname><given-names>M</given-names></name>, <name><surname>Loft</surname><given-names>S</given-names></name>, <name><surname>Wallin</surname><given-names>H</given-names></name>. <article-title>Inhalation of ozone induces DNA strand breaks and
inflammation in mice</article-title>. <source>Mutation Research/Genetic
Toxicology and Environmental Mutagenesis</source>.
<year>2002</year>;<volume>520</volume>(<issue>1</issue>):<fpage>63</fpage>&#x02013;<lpage>72</lpage>.</mixed-citation></ref><ref id="R40"><label>40.</label><mixed-citation publication-type="journal"><name><surname>Lippmann</surname><given-names>M</given-names></name>
<article-title>Health effects of ozone a critical review</article-title>.
<source>JAPCA</source>.
<year>1989</year>;<volume>39</volume>(<issue>5</issue>):<fpage>672</fpage>&#x02013;<lpage>95</lpage>.<pub-id pub-id-type="pmid">2659744</pub-id></mixed-citation></ref><ref id="R41"><label>41.</label><mixed-citation publication-type="journal"><name><surname>Kampa</surname><given-names>M</given-names></name>, <name><surname>Castanas</surname><given-names>E</given-names></name>. <article-title>Human health effects of air pollution</article-title>.
<source>Environmental pollution</source>.
<year>2008</year>;<volume>151</volume>(<issue>2</issue>):<fpage>362</fpage>&#x02013;<lpage>7</lpage>.<pub-id pub-id-type="pmid">17646040</pub-id></mixed-citation></ref><ref id="R42"><label>42.</label><mixed-citation publication-type="journal"><name><surname>Weschler</surname><given-names>CJ</given-names></name>. <article-title>Ozone&#x02019;s impact on public health: contributions
from indoor exposures to ozone and products of ozone-initiated
chemistry</article-title>. <source>Environ Health Perspect</source>.
<year>2006</year>:<fpage>1489</fpage>&#x02013;<lpage>96</lpage>.<pub-id pub-id-type="pmid">17035131</pub-id></mixed-citation></ref><ref id="R43"><label>43.</label><mixed-citation publication-type="journal"><name><surname>Passchier-Vermeer</surname><given-names>W</given-names></name>, <name><surname>Passchier</surname><given-names>WF</given-names></name>. <article-title>Noise exposure and public health</article-title>.
<source>Environ Health Perspect</source>.
<year>2000</year>;<volume>108</volume>
<issue>Suppl
1</issue>:<fpage>123</fpage>&#x02013;<lpage>31</lpage>.<pub-id pub-id-type="pmid">10698728</pub-id></mixed-citation></ref><ref id="R44"><label>44.</label><mixed-citation publication-type="journal"><name><surname>Zuidema</surname><given-names>C</given-names></name>, <name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Stebounova</surname><given-names>LV</given-names></name>, <name><surname>Gray</surname><given-names>A</given-names></name>, <name><surname>Liu</surname><given-names>X</given-names></name>, <name><surname>Tatum</surname><given-names>M</given-names></name>, <etal/>
<article-title>Mapping occupational hazards with a multi-sensor network in a
heavy-vehicle manufacturing facility</article-title>. <source>Annals of work
exposures and health</source>.
<year>2019</year>;<volume>63</volume>(<issue>3</issue>):<fpage>280</fpage>&#x02013;<lpage>93</lpage>.<pub-id pub-id-type="pmid">30715121</pub-id></mixed-citation></ref><ref id="R45"><label>45.</label><mixed-citation publication-type="journal"><name><surname>Hallett</surname><given-names>L</given-names></name>, <name><surname>Tatum</surname><given-names>M</given-names></name>, <name><surname>Thomas</surname><given-names>G</given-names></name>, <name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Koehler</surname><given-names>K</given-names></name>, <name><surname>Peters</surname><given-names>T</given-names></name>. <article-title>An inexpensive sensor for noise</article-title>.
<source>J Occup Environ Hyg</source>.
<year>2018</year>;<volume>15</volume>(<issue>5</issue>):<fpage>448</fpage>&#x02013;<lpage>54</lpage>.<pub-id pub-id-type="pmid">29420139</pub-id></mixed-citation></ref><ref id="R46"><label>46.</label><mixed-citation publication-type="journal"><name><surname>Berman</surname><given-names>JD</given-names></name>, <name><surname>Peters</surname><given-names>TM</given-names></name>, <name><surname>Koehler</surname><given-names>KA</given-names></name>. <article-title>Optimizing a Sensor Network with Data from Hazard
Mapping Demonstrated in a Heavy-Vehicle Manufacturing
Facility</article-title>. <source>Ann Work Expo Health</source>.
<year>2018</year>;<volume>62</volume>(<issue>5</issue>):<fpage>547</fpage>&#x02013;<lpage>58</lpage>.<pub-id pub-id-type="pmid">29562311</pub-id></mixed-citation></ref><ref id="R47"><label>47.</label><mixed-citation publication-type="journal"><name><surname>Afshar-Mohajer</surname><given-names>N</given-names></name>, <name><surname>Zuidema</surname><given-names>C</given-names></name>, <name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Hallett</surname><given-names>L</given-names></name>, <name><surname>Tatum</surname><given-names>M</given-names></name>, <name><surname>Rule</surname><given-names>AM</given-names></name>, <etal/>
<article-title>Evaluation of low-cost electro-chemical sensors for environmental
monitoring of ozone, nitrogen dioxide, and carbon monoxide</article-title>.
<source>J Occup Environ Hyg</source>.
<year>2018</year>;<volume>15</volume>(<issue>2</issue>):<fpage>87</fpage>&#x02013;<lpage>98</lpage>.<pub-id pub-id-type="pmid">29083958</pub-id></mixed-citation></ref><ref id="R48"><label>48.</label><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>Y</given-names></name>, <name><surname>Li</surname><given-names>J</given-names></name>, <name><surname>Jing</surname><given-names>H</given-names></name>, <name><surname>Zhang</surname><given-names>Q</given-names></name>, <name><surname>Jiang</surname><given-names>J</given-names></name>, <name><surname>Biswas</surname><given-names>P</given-names></name>. <article-title>Laboratory evaluation and calibration of three low-cost
particle sensors for particulate matter measurement</article-title>.
<source>Aerosol Science and Technology</source>.
<year>2015</year>;<volume>49</volume>(<issue>11</issue>):<fpage>1063</fpage>&#x02013;<lpage>77</lpage>.</mixed-citation></ref><ref id="R49"><label>49.</label><mixed-citation publication-type="journal"><name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Gray</surname><given-names>A</given-names></name>, <name><surname>Zuidema</surname><given-names>C</given-names></name>, <name><surname>Stebounova</surname><given-names>L</given-names></name>, <name><surname>Thomas</surname><given-names>G</given-names></name>, <name><surname>Koehler</surname><given-names>K</given-names></name>, <etal/>
<article-title>Sensor Selection to Improve Estimates of Particulate Matter
Concentration from a Low-Cost Network</article-title>.
<source>Sensors</source>.
<year>2018</year>;<volume>18</volume>(<issue>9</issue>):<fpage>3008</fpage>.</mixed-citation></ref><ref id="R50"><label>50.</label><mixed-citation publication-type="journal"><name><surname>Zuidema</surname><given-names>C</given-names></name>, <name><surname>Afshar-Mohajer</surname><given-names>N</given-names></name>, <name><surname>Tatum</surname><given-names>M</given-names></name>, <name><surname>Thomas</surname><given-names>G</given-names></name>, <name><surname>Peters</surname><given-names>T</given-names></name>, <name><surname>Koehler</surname><given-names>K</given-names></name>. <article-title>Efficacy of Paired Electrochemical Sensors for Measuring
Ozone Concentrations</article-title>. <source>J Occup Environ Hyg</source>.
<year>2018</year>(<comment>just-accepted</comment>):<fpage>1</fpage>&#x02013;<lpage>12</lpage>.<pub-id pub-id-type="pmid">29059039</pub-id></mixed-citation></ref><ref id="R51"><label>51.</label><mixed-citation publication-type="journal"><name><surname>Sueur</surname><given-names>J</given-names></name>, <name><surname>Aubin</surname><given-names>T</given-names></name>, <name><surname>Simonis</surname><given-names>C</given-names></name>. <article-title>Seewave: a free modular tool for sound analysis and
synthesis</article-title>. <source>Bioacoustics</source>.
<year>2008</year>;<volume>18</volume>:<fpage>213</fpage>&#x02013;<lpage>26</lpage>.</mixed-citation></ref><ref id="R52"><label>52.</label><mixed-citation publication-type="journal"><name><surname>Bland</surname><given-names>JM</given-names></name>, <name><surname>Altman</surname><given-names>D</given-names></name>. <article-title>Statistical methods for assessing agreement between two
methods of clinical measurement</article-title>. <source>The
lancet</source>.
<year>1986</year>;<volume>327</volume>(<issue>8476</issue>):<fpage>307</fpage>&#x02013;<lpage>10</lpage>.</mixed-citation></ref><ref id="R53"><label>53.</label><mixed-citation publication-type="journal"><name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Koehler</surname><given-names>K</given-names></name>, <name><surname>Thomas</surname><given-names>G</given-names></name>, <name><surname>Park</surname><given-names>JH</given-names></name>, <name><surname>Hillman</surname><given-names>M</given-names></name>, <name><surname>Halterman</surname><given-names>A</given-names></name>, <etal/>
<article-title>Inter-comparison of low-cost sensors for measuring the mass
concentration of occupational aerosols</article-title>. <source>Aerosol
Science and Technology</source>.
<year>2016</year>;<volume>50</volume>(<issue>5</issue>):<fpage>462</fpage>&#x02013;<lpage>73</lpage>.<pub-id pub-id-type="pmid">28867868</pub-id></mixed-citation></ref><ref id="R54"><label>54.</label><mixed-citation publication-type="journal"><name><surname>Hossain</surname><given-names>M</given-names></name>, <name><surname>Saffell</surname><given-names>J</given-names></name>, <name><surname>Baron</surname><given-names>R</given-names></name>. <article-title>Differentiating NO2 and O3 at Low Cost Air Quality
Amperometric Gas Sensors</article-title>. <source>ACS Sensors</source>.
<year>2016</year>;<volume>1</volume>(<issue>11</issue>):<fpage>1291</fpage>&#x02013;<lpage>4</lpage>.</mixed-citation></ref><ref id="R55"><label>55.</label><mixed-citation publication-type="journal"><name><surname>Spinelle</surname><given-names>L</given-names></name>, <name><surname>Gerboles</surname><given-names>M</given-names></name>, <name><surname>Aleixandre</surname><given-names>M</given-names></name>. <article-title>Performance Evaluation of Amperometric Sensors for the
Monitoring of O 3 and NO 2 in Ambient Air at ppb Level</article-title>.
<source>Procedia Engineering</source>.
<year>2015</year>;<volume>120</volume>:<fpage>480</fpage>&#x02013;<lpage>3</lpage>.</mixed-citation></ref><ref id="R56"><label>56.</label><mixed-citation publication-type="journal"><name><surname>Beekhuizen</surname><given-names>J</given-names></name>, <name><surname>Kromhout</surname><given-names>H</given-names></name>, <name><surname>Huss</surname><given-names>A</given-names></name>, <name><surname>Vermeulen</surname><given-names>R</given-names></name>. <article-title>Performance of GPS-devices for environmental exposure
assessment</article-title>. <source>Journal of Exposure Science and
Environmental Epidemiology</source>.
<year>2013</year>;<volume>23</volume>(<issue>5</issue>):<fpage>498</fpage>&#x02013;<lpage>505</lpage>.<pub-id pub-id-type="pmid">22829049</pub-id></mixed-citation></ref><ref id="R57"><label>57.</label><mixed-citation publication-type="journal"><name><surname>Adams</surname><given-names>C</given-names></name>, <name><surname>Riggs</surname><given-names>P</given-names></name>, <name><surname>Volckens</surname><given-names>J</given-names></name>. <article-title>Development of a method for personal, spatiotemporal
exposure assessment</article-title>. <source>J Environ Monit</source>.
<year>2009</year>;<volume>11</volume>(<issue>7</issue>):<fpage>1331</fpage>&#x02013;<lpage>9</lpage>.<pub-id pub-id-type="pmid">20449221</pub-id></mixed-citation></ref><ref id="R58"><label>58.</label><mixed-citation publication-type="confproc"><name><surname>Mainetti</surname><given-names>L</given-names></name>, <name><surname>Patrono</surname><given-names>L</given-names></name>, <name><surname>Sergi</surname><given-names>I</given-names></name>, editors. <source>A survey on indoor positioning systems</source>.
<conf-name>Software, Telecommunications and Computer Networks (Soft COM),
2014 22nd International Conference on</conf-name>; <year>2014</year>
<comment>2014</comment>: <publisher-name>IEEE</publisher-name>.</mixed-citation></ref><ref id="R59"><label>59.</label><mixed-citation publication-type="journal"><name><surname>Huang</surname><given-names>F-C</given-names></name>, <name><surname>Shih</surname><given-names>T-S</given-names></name>, <name><surname>Lee</surname><given-names>J-F</given-names></name>, <name><surname>Chao</surname><given-names>H-P</given-names></name>, <name><surname>Wang</surname><given-names>P-Y</given-names></name>. <article-title>Time location analysis for exposure assessment studies
of indoor workers based on active RFID technology</article-title>. <source>J
Environ Monit</source>.
<year>2010</year>;<volume>12</volume>(<issue>2</issue>):<fpage>514</fpage>&#x02013;<lpage>23</lpage>.<pub-id pub-id-type="pmid">20145895</pub-id></mixed-citation></ref><ref id="R60"><label>60.</label><mixed-citation publication-type="journal"><name><surname>Khoury</surname><given-names>HM</given-names></name>, <name><surname>Kamat</surname><given-names>VR</given-names></name>. <article-title>Evaluation of position tracking technologies for user
localization in indoor construction environments</article-title>.
<source>Automation in Construction</source>.
<year>2009</year>;<volume>18</volume>(<issue>4</issue>):<fpage>444</fpage>&#x02013;<lpage>57</lpage>.</mixed-citation></ref><ref id="R61"><label>61.</label><mixed-citation publication-type="book"><name><surname>Sakata</surname><given-names>M</given-names></name>, <name><surname>Yasumuro</surname><given-names>Y</given-names></name>, <name><surname>Imura</surname><given-names>M</given-names></name>, <name><surname>Manabe</surname><given-names>Y</given-names></name>, <name><surname>Chihara</surname><given-names>K</given-names></name>, editors. <source>A Location Awareness System Using Wide-angle Camera
and Active IR-Tag</source>. <publisher-name>MVA</publisher-name>;
<year>2002</year>
<volume>2002</volume>.</mixed-citation></ref><ref id="R62"><label>62.</label><mixed-citation publication-type="journal"><name><surname>Bai</surname><given-names>YB</given-names></name>, <name><surname>Wu</surname><given-names>S</given-names></name>, <name><surname>Wu</surname><given-names>HR</given-names></name>, <name><surname>Zhang</surname><given-names>K</given-names></name>, editors. <chapter-title>Overview of RFID-Based Indoor Positioning
Technology</chapter-title>
<source>GSR</source>; <year>2012</year>
<volume>2012</volume>: <comment>Citeseer.</comment></mixed-citation></ref><ref id="R63"><label>63.</label><mixed-citation publication-type="journal"><name><surname>Liu</surname><given-names>H</given-names></name>, <name><surname>Darabi</surname><given-names>H</given-names></name>, <name><surname>Banerjee</surname><given-names>P</given-names></name>, <name><surname>Liu</surname><given-names>J</given-names></name>. <article-title>Survey of wireless indoor positioning techniques
systems</article-title>. <source>IEEE Transactions on Systems, Man, and
Cybernetics, Part C (Applications and Reviews)</source>.
<year>2007</year>;<volume>37</volume>(<issue>6</issue>):<fpage>1067</fpage>&#x02013;<lpage>80</lpage>.</mixed-citation></ref><ref id="R64"><label>64.</label><mixed-citation publication-type="journal"><name><surname>Ahuja</surname><given-names>S</given-names></name>, <name><surname>Potti</surname><given-names>P</given-names></name>. <article-title>An introduction to RFID technology</article-title>.
<source>Communications and Network</source>.
<year>2010</year>;<volume>2</volume>(<issue>03</issue>):<fpage>183</fpage>.</mixed-citation></ref><ref id="R65"><label>65.</label><mixed-citation publication-type="journal"><name><surname>Lim</surname><given-names>MK</given-names></name>, <name><surname>Bahr</surname><given-names>W</given-names></name>, <name><surname>Leung</surname><given-names>SCH</given-names></name>. <article-title>RFID in the warehouse: A literature analysis
(1995&#x02013;2010) of its applications, benefits, challenges and future
trends</article-title>. <source>International Journal of Production
Economics</source>.
<year>2013</year>;<volume>145</volume>(<issue>1</issue>):<fpage>409</fpage>&#x02013;<lpage>30</lpage>.</mixed-citation></ref><ref id="R66"><label>66.</label><mixed-citation publication-type="journal"><name><surname>Sharma</surname><given-names>D</given-names></name>, <name><surname>Thomas</surname><given-names>GW</given-names></name>, <name><surname>Foster</surname><given-names>ED</given-names></name>, <name><surname>Iacovelli</surname><given-names>J</given-names></name>, <name><surname>Lea</surname><given-names>KM</given-names></name>, <name><surname>Streit</surname><given-names>JA</given-names></name>, <etal/>
<article-title>The precision of human-generated hand-hygiene observations: a
comparison of human observation with an automated monitoring
system</article-title>. <source>Infect Control Hosp Epidemiol</source>.
<year>2012</year>;<volume>33</volume>(<issue>12</issue>):<fpage>1259</fpage>&#x02013;<lpage>61</lpage>.<pub-id pub-id-type="pmid">23143367</pub-id></mixed-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Figure 1.</label><caption><p id="P31">Schematic of technique to estimate personal exposure from the sensor
network. Exposure estimates are derived by taking the hazard intensity at
location (x,y) for time t<sub>i</sub>, over the time period of interest.</p></caption><graphic xlink:href="nihms-1529902-f0001"/></fig><fig id="F2" orientation="portrait" position="float"><label>Figure 2.</label><caption><p id="P32">Examples of time series comparing network-derived exposure estimates
(dashed line) with personal DRI measurements (solid line) for a simulated mobile
employee for a) PM, b) CO, c) O<sub>3</sub>, and d) noise over the course of one
work shift.</p></caption><graphic xlink:href="nihms-1529902-f0002"/></fig><fig id="F3" orientation="portrait" position="float"><label>Figure 3.</label><caption><p id="P33">Bland-Altman plots of the difference between network-derived exposure
measurements and personal DRI measurements versus their mean for a) PM, b) CO,
c) O<sub>3</sub>, and d) noise. The solid line indicates the mean difference and
the dashed lines are the bounds of agreement. Circles are data from August 2017,
squares are data from December 2017, and triangles are data from March 2018.</p></caption><graphic xlink:href="nihms-1529902-f0003"/></fig><table-wrap id="T1" position="float" orientation="landscape"><label>Table 1.</label><caption><p id="P34">Comparison of personal DRI measurements and network-derived exposure
estimates (pairs of five-minute averages) for the mobile routine. Equipment
failure resulted in no personal noise measurements in March 2018.</p></caption><table frame="void" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="bottom" rowspan="1" colspan="1"/><th align="left" valign="bottom" rowspan="1" colspan="1"/><th align="center" valign="bottom" rowspan="1" colspan="1"/><th align="center" valign="bottom" rowspan="1" colspan="1"/><th align="center" valign="bottom" rowspan="1" colspan="1"/><th align="center" valign="bottom" rowspan="1" colspan="1"/><th align="center" valign="bottom" rowspan="1" colspan="1"/><th align="center" valign="bottom" rowspan="1" colspan="1"/><th colspan="4" align="left" valign="bottom" style="border-bottom:solid 1px" rowspan="1">Fraction within Percent of DRI<sup><xref rid="TFN2" ref-type="table-fn">1</xref></sup></th></tr><tr><th align="left" valign="bottom" rowspan="1" colspan="1">Hazard</th><th align="left" valign="bottom" rowspan="1" colspan="1">Time Period</th><th align="center" valign="bottom" rowspan="1" colspan="1"># Simulated Work Shifts, K</th><th align="center" valign="bottom" rowspan="1" colspan="1"># 5-min Pairs, N</th><th align="center" valign="bottom" rowspan="1" colspan="1">DRI GM (GSD)</th><th align="center" valign="bottom" rowspan="1" colspan="1">DRI AM (ASD)</th><th align="center" valign="bottom" rowspan="1" colspan="1">RMSE</th><th align="center" valign="bottom" rowspan="1" colspan="1">Pearson Correlation</th><th align="center" valign="bottom" rowspan="1" colspan="1">10</th><th align="center" valign="bottom" rowspan="1" colspan="1">25</th><th align="center" valign="bottom" rowspan="1" colspan="1">50</th><th align="center" valign="bottom" rowspan="1" colspan="1">100</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">PM</td><td align="left" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" style="border-bottom:solid 1px" rowspan="1" colspan="1">units:
mg/m<sup>3</sup></td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Aug-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">55</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.40 (1.62)</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.44 (0.20)</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.11</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.84</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.11</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.36</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.62</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.87</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Dec-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">153</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.28 (1.47)</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.30 (0.11)</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.09</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.60</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.18</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.41</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.7</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.92</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Mar-2018</td><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">162</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.48 (1.58)</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.52 (0.21)</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.16</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.39</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.15</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.3</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.7</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.98</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1"><bold>Combined</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>5</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>370</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.37 (1.65)</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.42 (0.20)</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.15</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.47</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.16</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.36</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.69</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.94</bold></td></tr><tr style="border-top:solid 1px"><td align="left" valign="top" rowspan="1" colspan="1">CO</td><td align="left" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" style="border-bottom:solid 1px" rowspan="1" colspan="1">units:
ppm</td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Aug-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">55</td><td align="center" valign="bottom" rowspan="1" colspan="1">4 (7)</td><td align="center" valign="bottom" rowspan="1" colspan="1">7 (4)</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.86</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.25</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.64</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.91</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.98</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Dec-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">156</td><td align="center" valign="bottom" rowspan="1" colspan="1">5 (1)</td><td align="center" valign="bottom" rowspan="1" colspan="1">5 (2)</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.59</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.25</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.63</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.9</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Mar-2018</td><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">169</td><td align="center" valign="bottom" rowspan="1" colspan="1">3 (6)</td><td align="center" valign="bottom" rowspan="1" colspan="1">4 (3)</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.41</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.22</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.53</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.72</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.84</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1"><bold>Combined</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>5</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>380</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>3 (4)</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>5 (3)</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>1</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.66</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.24</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.58</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.82</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.93</bold></td></tr><tr style="border-top:solid 1px"><td align="left" valign="top" rowspan="1" colspan="1">O<sub>3</sub></td><td align="left" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" style="border-bottom:solid 1px" rowspan="1" colspan="1">units:
ppb</td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Aug-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">55</td><td align="center" valign="bottom" rowspan="1" colspan="1">19 (2)</td><td align="center" valign="bottom" rowspan="1" colspan="1">24 (14)</td><td align="center" valign="bottom" rowspan="1" colspan="1">11</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.63</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.02</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.02</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.02</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.02</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Dec-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">91</td><td align="center" valign="bottom" rowspan="1" colspan="1">29 (1)</td><td align="center" valign="bottom" rowspan="1" colspan="1">30 (9)</td><td align="center" valign="bottom" rowspan="1" colspan="1">24</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.05</td><td align="center" valign="bottom" rowspan="1" colspan="1">0</td><td align="center" valign="bottom" rowspan="1" colspan="1">0</td><td align="center" valign="bottom" rowspan="1" colspan="1">0</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.03</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Mar-2018</td><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">168</td><td align="center" valign="bottom" rowspan="1" colspan="1">111 (2)</td><td align="center" valign="bottom" rowspan="1" colspan="1">130 (71)</td><td align="center" valign="bottom" rowspan="1" colspan="1">31</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.54</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.12</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.37</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.7</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.84</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1"><bold>Combined</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>4</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>314</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>54 (3)</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>82 (73)</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>27</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.54</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.07</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.2</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.38</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.46</bold></td></tr><tr style="border-top:solid 1px"><td align="left" valign="top" rowspan="1" colspan="1">Noise</td><td align="left" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" style="border-bottom:solid 1px" rowspan="1" colspan="1">units:
dBA</td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Aug-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">55</td><td align="center" valign="bottom" rowspan="1" colspan="1">83 (3)<sup><xref rid="TFN3" ref-type="table-fn">2</xref></sup></td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.23</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.96</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Dec-2017</td><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">156</td><td align="center" valign="bottom" rowspan="1" colspan="1">83 (3)<sup><xref rid="TFN3" ref-type="table-fn">2</xref></sup></td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1">2</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.43</td><td align="center" valign="bottom" rowspan="1" colspan="1">0.96</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td><td align="center" valign="bottom" rowspan="1" colspan="1">1</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1">Mar-2018</td><td align="center" valign="bottom" rowspan="1" colspan="1">0</td><td align="center" valign="bottom" rowspan="1" colspan="1">0</td><td align="center" valign="bottom" rowspan="1" colspan="1">--</td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1">--</td><td align="center" valign="bottom" rowspan="1" colspan="1">--</td><td align="center" valign="bottom" rowspan="1" colspan="1">--</td><td align="center" valign="bottom" rowspan="1" colspan="1">--</td><td align="center" valign="bottom" rowspan="1" colspan="1">--</td><td align="center" valign="bottom" rowspan="1" colspan="1">--</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="bottom" rowspan="1" colspan="1"><bold>Combined</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>3</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>211</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>83 (3)</bold><sup><xref rid="TFN3" ref-type="table-fn">2</xref></sup></td><td align="center" valign="bottom" rowspan="1" colspan="1"/><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>3</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.39</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>0.96</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>1</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>1</bold></td><td align="center" valign="bottom" rowspan="1" colspan="1"><bold>1</bold></td></tr></tbody></table><table-wrap-foot><title>Notes:</title><fn id="TFN2"><label>1</label><p id="P36">Fraction of network-derived exposure estimates that were within
(&#x000b1;) 10, 25, 50 and 100% of the personal DRI measurements for each
hazard.</p></fn><fn id="TFN3"><label>2</label><p id="P37">Noise calculations were performed on data transformed to the linear
scale then transformed back to the dBA scale, and are not technically GMs
and GSDs. GM: geometric mean</p></fn><fn id="TFN4"><p id="P38">GSD: geometric standard deviation</p></fn><fn id="TFN5"><p id="P39">AM: arithmetic mean</p></fn><fn id="TFN6"><p id="P40">ASD: arithmetic standard deviation</p></fn><fn id="TFN7"><p id="P41">RMSE: root mean square error</p></fn></table-wrap-foot></table-wrap></floats-group></article>