i
Fatal Case of Nosocomial Legionella pneumophila Pneumonia, Spain, 2018
-
November 2019
Source: Emerg Infect Dis. 25(11):2097-2099
Details:
-
Alternative Title:Emerg Infect Dis
-
Personal Author:
-
Description:A nosocomial case of Legionella pneumophila pneumonia likely caused by a serogroup 3 strain was detected by a urinary antigen test in Spain in 2018. Although Legionella bacteria could not be isolated from respiratory samples, molecular methods implicated the sink faucet of the patient's room as the probable infection source.
-