i
LED lighting for improving trip object detection for a walk-thru roof bolter
-
July 03 2018
Source: Light Res Technol. 51(5):725-741
Details:
-
Alternative Title:Light Res Technol
-
Personal Author:
-
Description:Proper lighting plays a critical role in enabling miners to detect hazards when operating a roof bolter, one of the most dangerous mining machines to operate; however, there has not been any lighting research to address the walk-thru type of roof bolter commonly used today. To address this, the Saturn light was designed to directly address walk-thru roof bolter safety by improving trip hazard illumination. The visual performances of 30 participants that comprised three age groups were quantified by measuring each participant's visual performance in detecting trip objects positioned on the two floor locations within the machine's interior working space. The lighting conditions were the existing compact fluorescent lights (CFLs) and the Saturn LED area light developed by NIOSH researchers. Three intensities of the Saturn lights were used, 100%, 75%, and 50%, all of which resulted in better visual performance, and up to a 48% reduction in average trip detection time compared to the CFL. For the Saturn trip object miss rates were <0.5% for all age groups in contrast to the CFL, which ranged between 32.5% for the youngest group and 50.4% for the oldest group.
-
Subjects:
-
Source:
-
Pubmed ID:30174557
-
Pubmed Central ID:PMC6112606
-
Document Type:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type:
Supporting Files
-
gif jpeg gif jpeg gif jpeg gif jpeg gif jpeg gif gif jpeg xml jpeg gif jpeg gif jpeg gif jpeg