<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101559077</journal-id><journal-id journal-id-type="pubmed-jr-id">39692</journal-id><journal-id journal-id-type="nlm-ta">Footwear Sci</journal-id><journal-id journal-id-type="iso-abbrev">Footwear Sci</journal-id><journal-title-group><journal-title>Footwear science</journal-title></journal-title-group><issn pub-type="ppub">1942-4280</issn><issn pub-type="epub">1942-4299</issn></journal-meta><article-meta><article-id pub-id-type="pmid">30956751</article-id><article-id pub-id-type="pmc">6444364</article-id><article-id pub-id-type="doi">10.1080/19424280.2018.1486463</article-id><article-id pub-id-type="manuscript">HHSPA1014694</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Method for measuring wear on boot outsoles using a 3D laser
scanner</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Whitson</surname><given-names>Ashley E.</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-3680-9314</contrib-id><xref rid="CR1" ref-type="corresp">*</xref></contrib><contrib contrib-type="author"><name><surname>Kocher</surname><given-names>Lydia M.</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-4372-2284</contrib-id></contrib><contrib contrib-type="author"><name><surname>Pollard</surname><given-names>Jonisha</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0001-9282-9120</contrib-id></contrib><contrib contrib-type="author"><name><surname>Nasarwanji</surname><given-names>Mahiyar</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-3961-3432</contrib-id></contrib><aff id="A1">National Institute for Occupational Safety and Health &#x02013;
Pittsburgh Research Laboratory, Pittsburgh, PA, USA</aff></contrib-group><author-notes><corresp id="CR1"><label>*</label>Corresponding author.
<email>awhitson@cdc.gov</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>2</day><month>3</month><year>2019</year></pub-date><pub-date pub-type="epub"><day>5</day><month>10</month><year>2018</year></pub-date><pub-date pub-type="ppub"><year>2018</year></pub-date><pub-date pub-type="pmc-release"><day>05</day><month>10</month><year>2019</year></pub-date><volume>10</volume><issue>3</issue><fpage>149</fpage><lpage>155</lpage><!--elocation-id from pubmed: 10.1080/19424280.2018.1486463--><abstract id="ABS1"><p id="P1">In the mining industry, slips and falls are the second leading cause of
non-fatal injuries. Footwear is the primary defence against a slip;
consequently, the condition of the footwear outsole is critical to maintaining
slip resistance. Currently, there is no published method that can be used to
determine when the outsole no longer affords adequate slip protection. Moreover,
quantifying the condition of the outsole through the measurement of outsole
features can be tedious. This article introduces a new method for the
quantification of boot outsole wear. Using a handheld 3D scanner, boot scans can
be taken quickly and the developed models used to measure outsole features. This
method also accounts for the bending of the boot due to normal wear, which may
otherwise introduce erroneous measures. When compared to measurements with a
traditional handheld calliper, this new method offers more flexibility in terms
of data collection, accounts for other types of boot transformations, and is
more efficient to use over multiple measurement periods with no statistically
significant differences in measurement.</p></abstract><kwd-group><kwd>boot tread</kwd><kwd>wear pattern</kwd><kwd>3D scanner</kwd><kwd>metrology</kwd><kwd>mining</kwd><kwd>slips</kwd><kwd>tread wear</kwd></kwd-group></article-meta></front><body><sec id="S1"><title>Introduction</title><p id="P2">Mining is a hazardous occupation that requires workers to wear personal
protective equipment to reduce the risk for injury due to the work environment. The
Mine Safety and Health Administration requires that workers wear suitable safety
footwear to protect their feet from the dangers of the environment [30 CFR 56.15003
(1985)]. While this safety footwear may protect the toes and feet from falling
objects, it may also put a miner at risk if it is improperly designed for the
working surfaces or if the outsole is worn and does not provide adequate slip
protection. Work boots that are well suited for a work environment still require
monitoring to ensure they are in good working condition and provide adequate
traction to prevent slips.</p><p id="P3">It has been established that adequate tread depth on the outsoles of footwear
is necessary to prevent slips by allowing the evacuation of fluid from beneath the
foot (<xref rid="R3" ref-type="bibr">Beschorner &#x00026; Singh, 2012</xref>). As the
boot outsoles wear, this tread depth diminishes, which affects fluid evacuation and
could reduce slip performance. The ability of a boot to prevent slips may not be as
easy to determine by the user as would other, more visible signs of wear and damage.
Miners may consider their boots to be worn out for a variety of reasons, including
visible cracks, worn out treads, leaks, or discomfort. While all of these reasons
are important for worker comfort, slip protection is a key element for overall
worker safety.</p><p id="P4">Most companies replace footwear at a predetermined time interval or based on
appearance and comfort (<xref rid="R5" ref-type="bibr">Chiou, Bhattacharya, &#x00026;
Succop, 1996</xref>) with little knowledge on the actual changes in tread depth
(wear) of the footwear and its influence on the likelihood of a slip, trip, or fall
(STF) event. Previously, some studies have examined artificially worn shoes to
better understand the influence of wear (<xref rid="R9" ref-type="bibr">Kim,
2012</xref>), while others have utilized shoes worn naturally for slip testing
(<xref rid="R5" ref-type="bibr">Chiou et al., 1996</xref>). Although there have
been attempts to quantify wear in industrial settings based on wear pattern, tread
pattern, and hardness (<xref rid="R5" ref-type="bibr">Chiou et al., 1996</xref>),
there is a lack of knowledge in the mining industry on how quickly the outsoles of
work boots wear, what levels of wear occur, the locations of wear, and how wear
patterns are influenced by routine work activities. In order to gather this
information, it is important to have a method that allows the wear to be tracked
over time.</p><p id="P5">Currently, no standard method exists for measuring the wear of boot outsoles.
Sheets and colleagues (<xref rid="R10" ref-type="bibr">Sheets, Gross, Langenburg,
Bush, &#x00026; Bush, 2013</xref>) collected two-dimensional scans and superimposed
a sub-grid over the scans to quantify the rate of texture loss on athletic shoes.
The researchers then examined and reported the percentage of grid cells that
indicated loss of texture. While this method allowed for the loss of texture to be
interpreted, it did not calculate the exact loss of material or changes in tread
depth. In contrast, <xref rid="R5" ref-type="bibr">Chiou et al. (1996)</xref>
examined the wear patterns of shoes using physical callipers to measure the tread
thickness on the medial and lateral sides of the shoes from heel to toe. Wear
patterns were determined from creating a three-dimensional graph and interpolating
between measurements (<xref rid="R5" ref-type="bibr">Chiou et al., 1996</xref>).
This method allowed for material loss to be calculated, but there was a large degree
of interpolation and the researchers did not collect any measurements in the middle
of the shoe. Similar to Chiou et al. and <xref rid="R6" ref-type="bibr">Gr&#x000f6;nqvist (1995)</xref> measured the profile depth of the treads and
number of months the boots were worn to define the wear condition. Additionally,
some studies have used laser scanning confocal microscopes to measure surface
roughness changes (<xref rid="R7" ref-type="bibr">Kim, 2004</xref>, <xref rid="R8" ref-type="bibr">2015</xref>). While all of the previously mentioned studies
utilized valid approaches to measure some form of wear, most measured wear and its
relationship to slip resistivity. Consequently, the studies did not focus on the
actual quantification of changes in tread depth from the entire boot outsole as a
means to develop metrics for boot replacement.</p><p id="P6">Quantifying boot wear over time can be challenging due to changes in the boot
shape that occur as a result of normal wear. Bending and twisting of boots over time
can make repeated measurement of the tread difficult because both the outsole and
the associated reference (deep sole) may be altered between measurements. The
purpose of this study was to develop a standardized, repeatable, and accurate method
to quantify changes in tread depth of work boots over time. The following method
accounts for changes in boot outsole shape by using a 3 D laser scanner with virtual
measurement tools to isolate areas of interest and select appropriate, consistent
reference points. This work is part of a larger longitudinal study that evaluates
boot wear in the mining industry to provide guidance on boot replacement.</p></sec><sec id="S2"><title>Materials and methods</title><p id="P7">This study utilized two different boots for method development. Boot 1 was a
steel-toed work boot (Timberland Pro Series, 72398, USA) that was artificially worn
and deformed. Boot 2 was a steel-toed work boot with metatarsal guards (Matterhorn,
CV12000, USA) that was worn by a mine worker for 6 months during regular work
duties. Both boots were scanned initially before any wear was introduced. The
objective was to track wear over time, so both boots were scanned and measured at
multiple points in time. After the initial scan was collected, Boot 1 was
artificially worn using a grinder to remove material on the outsole and was stored
with the toe of the boot in a bent position under weights (~30 kg) for three
weeks to simulate toe flexion at the ball of the foot and changes in geometry that
could be created from normal use (first wear period). A second scan was collected
and measurements were taken and then the process was repeated (second wear period).
Boot 2 was scanned before it was given to the mine worker and then scans and
measurements were taken 3 months (first wear period) and 6 months (second wear
period) after the initial scan. For the purpose of this paper, the outsole is
defined as the exposed part of the boot that sits below the foot. The surface tread
is the outermost part of the outsole that contacts the ground. The deep sole or deep
tread is the part of the outsole closest to the foot, which does not typically
contact the ground (<xref rid="F1" ref-type="fig">Figure 1</xref>).</p><p id="P8">The boots were prepared and cleaned before being scanned with the 3D laser
scanner. Then meshes, created from the scans, were primed and metrology software was
used to measure the differences between the meshes. This process was repeated for
each wear period and the average loss in tread was calculated to quantify boot wear.
To test the accuracy of this method, the measurements from the scans were compared
to manual calliper measurements using a paired samples <italic>t</italic>-test with
an alpha level of 0.05. Detailed methods are described below.</p><sec id="S3"><title>Preparation</title><p id="P9">The boots were prepared for scanning by first cleaning and drying the
outsoles completely to avoid influencing measurements. The outsoles were then
sprayed with developer spray (Magnaflux Spotcheck SKD-S2, USA) and the excess
powder was brushed away. The developer spray aids in scanning without
significantly adding materials to the outsole. Boots were placed in a
custom-built rig (<xref rid="F2" ref-type="fig">Figure 2</xref>) with the
outsole of the boot visible and the shaft secured. Black contour positioning
targets were randomly placed on the flat surface of the rig and along the upper
part of the boot with no targets located on the actual outsole, the area of
interest. These retro-reflective targets assist in positioning and allow the 3D
scanner to provide accurate measurements (<xref rid="R2" ref-type="bibr">Allard
&#x00026; Lavoie, 2014</xref>).</p></sec><sec id="S4"><title>Scanning</title><p id="P10">After the boots were prepared, scanning took place following the
manufacturer&#x02019;s instructions. The HandySCAN 3D 700 laser scanner was used
(Creaform, Levis, QC, Canada) with the accompanying software, VXelements, VXscan
(Creaform, Levis, QC, Canada) to collect the scans. The scanner was calibrated
using the provided calibration plate. Scanner shutter speed configuration was
completed with each boot by using the Auto Adjust feature and manually adjusting
if necessary. Darker treads required higher shutter speeds. After setup and
calibration, the boot was scanned until all outsole features were present in the
scan, which takes ~20 min per boot. Next, the scan was trimmed so that
only the tread of the boot was present. The positioning model, which is a map of
all the positioning targets, was auto-optimized by the software and the scanning
session and the associated mesh file were saved at a resolution of 0.2 mm.</p></sec><sec id="S5"><title>Mesh preparation</title><p id="P11">After scanning was completed, the meshes of the initial boot and the
worn boot were imported into VXelements, VXmodel (Creaform, Levis, QC, Canada).
Each mesh was cleaned using built-in functions to remove data anomalies such as
very small holes, spikes, and isolated patches that were not part of the
outsole. Scanning results in a point cloud that when joined by triangles creates
a surface, or mesh, that aids in viewing the surface contours. These point
clouds can sometimes have small irregularities, which can lead to variances like
intersecting triangles, or spikes, in the mesh. Cleaning the mesh allows the
software to generate a smooth surface from the point cloud collected by the 3D
scanner. The two meshes were prealigned by choosing corresponding point pairs on
the deepest part of the tread (deep sole) of the heel of each mesh (<xref rid="F1" ref-type="fig">Figure 1</xref>) where wear was not anticipated.
These temporary point pairs show the program common points between the meshes to
facilitate the alignment. The meshes were then aligned using the
&#x0201c;best-fit&#x0201d; option in the software. After the first wear period,
the meshes were still slightly misaligned, especially in the toe (Figure 5).
This misalignment, primarily due to bending or twisting, made comparison of the
3D scans a challenge. To account for this bending, the meshes were separated
into five regions based on a plane that was placed on the stacked part of the
heel. The regions were heel, arch, arch-ball, ball, and toe (<xref rid="F1" ref-type="fig">Figure 1</xref>). Each region was exported separately as a
new mesh.</p><p id="P12">The initial and worn meshes for each region of the boots were
transferred into PolyWorks, IMInspect software (InnovMetric Software,
Qu&#x000e9;bec, QC, Canada). The initial mesh of the boot, prior to the first
wear period, was converted to a reference object and the worn mesh was loaded as
a data object. The meshes were then realigned using the &#x0201c;best fit&#x0201d;
after the selection of the pre-alignment point pairs as described earlier. To
counteract the bending and twisting, the pre-alignment point pairs were again
placed on the deep sole of the outsole, as described earlier.</p></sec><sec id="S6"><title>Metrology</title><p id="P13">To further account for the bending and other transformations within each
region, additional care was taken to ensure accurate measurements by using
comparison points on the deep sole. These comparison points were used to
calculate an average deviation between two meshes (initial and worn) within a
disc of specified radius (InnovMetric Software, Quebec, QC, Canada). To
calculate the tread wear, virtual calliper points with offset axes were used on
the surface tread. The first endpoint of the calliper was placed on the surface
tread and the second endpoint was placed within the diameter of a nearby
comparison point on the deep sole (Figures <xref rid="F3" ref-type="fig">3</xref> and <xref rid="F4" ref-type="fig">4</xref>). Virtual callipers
were linked to the worn mesh (data object) and comparison points were linked to
the initial mesh (reference object). Placement of each calliper point was
determined when viewing the initial mesh.</p><p id="P14">Tables were exported with the measured and nominal values that were used
to calculate wear. The &#x0201c;measured&#x0201d; value that was returned
represented the shortest distance between the two virtual calliper end points on
the worn mesh. The &#x0201c;nominal&#x0201d; value that was returned represented
the shortest distance between the two calliper end points on the initial mesh.
The reported &#x0201c;deviation&#x0201d; was the difference between the measured
and nominal values. Once tables for these values were exported, the comparison
point values were subtracted from the corresponding calliper deviation values.
This subtraction accounted for the difference between the deep soles of the two
meshes, which theoretically, should not show any signs of wear. By using this
final calculation, the bending, twisting, and other flexible transformations
were accounted for so that the final deviation values represented only the
change in tread wear. For the example in <xref rid="F3" ref-type="fig">Figure
3</xref>, the deviation between the two meshes for &#x0201c;calliper
1&#x0201d; was reported as &#x02212;0.288 mm, but the actual wear would be
&#x02212;0.365mm after accounting for the misalignment captured from the
comparison point (surf pt 1). An example of calliper and associated comparison
point placement for Boot 2 is shown in <xref rid="F4" ref-type="fig">Figure
4</xref>. The arch region of the boot was not utilized in final wear
measurements because there were no prominent surface tread features.</p><p id="P15">To measure wear on the same boot for subsequent wear periods, the worn
mesh from the following period was imported into the same VXmodel session as the
first worn mesh and the method was repeated. The first worn mesh was deleted
from the IMInspect project and then the software automatically updated the
measured components and new deviation values were calculated. A total of 171
virtual calliper points and 75 comparison points were collected from Boot 1, and
178 virtual calliper points and 88 comparison points were collected from Boot 2
(<xref rid="F4" ref-type="fig">Figure 4</xref>). To compare this new method
to previously used methods, tread wear measurements were also collected with
manual callipers (Fowler Digital Calliper, 0.02-mm accuracy) at the end of the
second wear period for each boot. Where space allowed, measurements were taken
in some of the same locations on the outsole as with the virtual callipers.
Because of the size and shape of the callipers, it was not possible to collect
all of the same measurements. Only points measured using both methods&#x02014;98
and 140 for Boot 1 and Boot 2, respectively&#x02014;were considered for the
comparison.</p></sec></sec><sec id="S7"><title>Results</title><p id="P16">For Boot 1, the toe of the boot was bent towards the upper part of the boot
while it was stored and this was evident in the scans. Similar effects were seen for
Boot 2 (<xref rid="F5" ref-type="fig">Figure 5</xref>). These images were rendered
after the scans of the entire outsole were aligned in VXModel. After the outsoles
were cut into sections and realigned, much of this misalignment was corrected (<xref rid="F5" ref-type="fig">Figures 5c and d</xref>). <xref rid="T1" ref-type="table">Table 1</xref> shows the results of the tread wear measurements
on both boots using the developed method introduced in this paper and using digital
callipers. Statistical analysis using a paired samples <italic>t</italic>-test
revealed no statistically significant differences in the tread wear measured using
digital callipers and that calculated from the scan (<italic>p</italic> &#x0003e;
.05).</p></sec><sec id="S8"><title>Discussion</title><p id="P17">This article introduced a method for tread wear measurement from 3D scans of
the outsole of boots using metrology software. Compared to taking calliper
measurements by hand, this method yielded highly similar results. This new method,
using a 3D scanner and metrology software, allows for measurements to be taken at
multiple wear intervals, while digitally preserving the tread features for future
reference. After the initial setup, subsequent wear period measurements can be
quickly assessed, as the program keeps track of the exact location of the
measurements. This also eliminates human error associated with matching the location
of the wear points to measure at each wear interval.</p><p id="P18">Traditional callipers, as used by <xref rid="R5" ref-type="bibr">Chiou et
al. (1996)</xref> and <xref rid="R6" ref-type="bibr">Gr&#x000f6;nqvist
(1995)</xref>, are limited in that they can only measure along one axis, whereas
metrology software allows for more flexibility with calliper placement. The first
and second endpoints can be positioned separately, allowing for more data points
with the new method. Essentially, this allows for the placement of measurement
points where a traditional calliper would not fit. Another problem with traditional
callipers is that the base of the device is two-sided, which means that the base
rests on two treads and the depth is measured in the middle of the two. However, if
one tread is more worn than the adjacent one, traditional callipers may not account
for this difference. If the calliper base is balanced on just one tread, it must be
aligned parallel to the deep sole of the boot, which can only be approximated. In
addition, if there is a gouge or piece of sole missing from the middle of a tread,
it is impossible to measure with traditional callipers. Both of these problems can
be avoided using the approach described in this article. Furthermore, using 3D scans
and saving the meshes allows the initial and subsequent samples from the various
wear periods to be preserved even if the boot is not available. This is ideal for
the longitudinal tracking of boots. In addition, they can be used for future
analysis as needed. As scanning is not time consuming, researchers can scan the boot
and return it to the user and perform measurements later, unlike with traditional
callipers where measurements must be collected immediately, resulting in lengthy
measurement periods.</p><p id="P19">When compared to the method of mapping wear distribution (<xref rid="R1" ref-type="bibr">Affatato, Valigi, &#x00026; Logozzo, 2017</xref>), the metrology
method for tread wear measurement allows for bends and other changes to be separated
from the changes in tread depth. If the meshes were perfectly aligned, it would be
possible to use the 3D deviation color map in VXelements, as <xref rid="R1" ref-type="bibr">Affatato et al. (2017)</xref> did with knee prostheses. However,
because the boots are flexible and there are transformations other than changes in
tread depth, this approach was not feasible.</p><p id="P20">There are a few key factors to consider when using this metrology method.
Before scanning, it is important to make sure boots are cleaned thoroughly. Debris
on the boots can interfere with the scan or placement of points. It is also
important to keep the initial mesh orientation fixed within the software so that
measurements are reported correctly.</p><sec id="S9"><title>Limitations and future directions</title><p id="P21">Using 3D scans of boots to measure tread wear is not without its
limitations. One drawback can occur when boots are drastically misshapen between
wear periods. In these cases, the locations of certain callipers may no longer
be applicable. This requires that the boots be closely examined during the
measurements at each wear period. In addition, this method was developed using
safety shoes with steel toes and has not been tested on other types of footwear.
For instance, for boots without a pronounced surface tread, this method does not
work as well. We have assumed that the deep tread is invariant; however, for
boots with shallow surface treads, it is possible that the deep sole can lose
material, leaving nothing from which to measure. One other possible limitation
is cost. The HandySCAN 3D 700 laser scanner costs over $50,000 (USD) and was
selected for its portability and high resolution (0.05 mm) that could be useful
for future projects. However, with recent advances in 3D scanning technology,
handheld scanners with a resolution of 0.5mm are available for under $6,000
(USD) (e.g. Peel 3d Scanner, Afinia EinScan-Pro+ 3D Scanner).</p><p id="P22">Another limitation is that the use of comparison points from separate
scans introduces error. The comparison points account for the differences in the
deep sole of two scans. We assume that this change is due to the bending of the
boot; however, it is possible that some of this change is due to misalignment of
the scans within the program. That is, in some locations, the deviation may be
overestimated and in others it may be underestimated. This error is unavoidable
due to software limitations. However, the software makes it possible to quickly
take measurements in the same locations over several wear periods, which would
be more prone to error if done by hand. This method could be adjusted and
applied to longitudinal tracking studies for other industries such as
construction, athletics, or restaurants to see how tread wear can affect other
professionals. This method could also be used to quantify wear and provide
guidance on when boots should be replaced.</p></sec></sec><sec id="S10"><title>Conclusion</title><p id="P23">The method for tread wear measurement introduced in this article utilizes 3D
scanning and metrology software to quantify changes in tread depth over time. When
compared to using a handheld calliper, there was no statistically significant
difference between the two methods (<italic>p</italic>&#x0003e;.05). The metrology
method allows the user to collect 3D renderings of boot outsoles so that
measurements can be performed at a later time. Using virtual callipers allows for
more flexibility in the placement of the points than would be accessible with manual
callipers. Similarly, using virtual callipers means that the placement of these
points is preserved through multiple wear periods, eliminating the approximation
introduced with manual callipers. While there are a few limitations with this
method, such as the requirement of a pronounced surface tread and a small amount of
error, it ultimately allows for flexibility and efficiency when taking measurements.
This metrology method can be used to provide objective guidance to the mining
industry on when boots should be replaced due to wear. In the future, this metrology
method can be adapted to measure tread wear for other types of footwear across
multiple industries.</p></sec></body><back><ack id="S11"><title>Acknowledgements</title><p id="P24">Funding for this project was provided by the National Institute for
Occupational Safety and Health. The authors would like to thank Mary Ellen Nelson
for her work in creating the custom-built rig and Tim Orr, Joe Schall, and Dr.
Patrick Dempsey for their constructive comments.</p></ack><fn-group><fn fn-type="COI-statement" id="FN1"><p id="P25">Disclosure statement</p><p id="P26">No potential conflict of interest was reported by the authors. The
findings and conclusions in this report are those of the authors and do not
necessarily represent the official position of the National Institute for
Occupational Safety and Health, Centers for Disease Control and Prevention.
Mention of any company or product does not constitute endorsement by the
National Institute for Occupational Safety and Health (NIOSH), Centers for
Disease Control and Prevention (CDC).</p></fn></fn-group><ref-list><title>References</title><ref id="R1"><mixed-citation publication-type="journal"><name><surname>Affatato</surname><given-names>S</given-names></name>, <name><surname>Valigi</surname><given-names>M</given-names></name>, &#x00026; <name><surname>Logozzo</surname><given-names>S</given-names></name> (<year>2017</year>). <article-title>Wear distribution detection of knee
joint prostheses by means of 3D optical scanners</article-title>.
<source>Materials</source>, <volume>10</volume>, <fpage>364</fpage>.
doi:<pub-id pub-id-type="doi">10.3390/ma10040364</pub-id></mixed-citation></ref><ref id="R2"><mixed-citation publication-type="confproc"><name><surname>Allard</surname><given-names>PH</given-names></name>, &#x00026; <name><surname>Lavoie</surname><given-names>JA</given-names></name> (<year>2014</year>). <source>Differentiation of 3D scanners and their
positioning method when applied to pipeline integrity</source>.
<conf-name>Paper presented at the NDT 2014 &#x02013; 53rd Annual Conference
of the British Institute of Non-Destructive Testing, The Palace
Hotel</conf-name>, <conf-loc>Manchester, United
Kingdom</conf-loc>.</mixed-citation></ref><ref id="R3"><mixed-citation publication-type="confproc"><name><surname>Beschorner</surname><given-names>K,E</given-names></name>, &#x00026; <name><surname>Singh</surname><given-names>G</given-names></name> (<year>2012</year>). <source>A novel method for evaluating the
effectiveness of shoe-tread designs relevant to slip and fall
accidents</source>. <conf-name>Paper presented at the Proceedings of the
Human Factors and Ergonomics Society, Westin Boston Waterfront</conf-name>,
<conf-loc>Boston, Massachusetts, USA</conf-loc>.</mixed-citation></ref><ref id="R4"><mixed-citation publication-type="book"><collab>Code of Federal
Regulations</collab>, 30 C.F.R. 56.15003, &#x0201c;<source>Protective
Footwear</source>,&#x0201d; <publisher-name>U.S. Department of Labor, Mine
Safety and Health Administration, U.S. Government Printing Office, Office of
the Federal Register</publisher-name>, <publisher-loc>Washington,
D.C.</publisher-loc></mixed-citation></ref><ref id="R5"><mixed-citation publication-type="journal"><name><surname>Chiou</surname><given-names>SY</given-names></name>, <name><surname>Bhattacharya</surname><given-names>A</given-names></name>, &#x00026; <name><surname>Succop</surname><given-names>PA</given-names></name> (<year>1996</year>). <article-title>Effect of workers&#x02019; shoe wear
on objective and subjective assessment of slipperiness</article-title>.
<source>American Industrial Hygiene Association Journal</source>,
<volume>57</volume>, <fpage>825</fpage>&#x02013;<lpage>831</lpage>.
doi:<pub-id pub-id-type="doi">10.1080/15428119691014503</pub-id><pub-id pub-id-type="pmid">8865591</pub-id></mixed-citation></ref><ref id="R6"><mixed-citation publication-type="journal"><name><surname>Gr&#x000f6;nqvist</surname><given-names>R</given-names></name> (<year>1995</year>). <article-title>Mechanisms of friction and
assessment of slip resistance of new and used footwear soles on contaminated
floors</article-title>. <source>Ergonomics</source>, <volume>38</volume>,
<fpage>224</fpage>&#x02013;<lpage>241</lpage>. doi:<pub-id pub-id-type="doi">10.1080/00140139508925100</pub-id><pub-id pub-id-type="pmid">28084937</pub-id></mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>I-J</given-names></name> (<year>2004</year>). <article-title>Development of a new analyzing model
for quantifying pedestrian slip resistance characteristics: part
II&#x02014;Experiments and validations</article-title>. <source>International
Journal of Industrial Ergonomics</source>, <volume>33</volume>,
<fpage>403</fpage>&#x02013;<lpage>414</lpage>.doi:<pub-id pub-id-type="doi">10.1016/j.ergon.2003.10.011</pub-id></mixed-citation></ref><ref id="R8"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>I-J</given-names></name> (<year>2015</year>). <article-title>Wear observation of shoe surfaces:
Application for slip and fall safety assessments</article-title>.
<source>Tribology Transactions</source>, <volume>58</volume>,
<fpage>407</fpage>&#x02013;<lpage>417</lpage>. doi:<pub-id pub-id-type="doi">10.1080/10402004.2014.980593</pub-id></mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>JS</given-names></name> (<year>2012</year>). <article-title>A comparison of slip resistance
between the grinded outsoles and new ones of fire fighter's
shoes</article-title>. <source>Procedia Engineering</source>,
<volume>45</volume>, <fpage>868</fpage>&#x02013;<lpage>874</lpage>.
doi:<pub-id pub-id-type="doi">10.1016/j.proeng.2012.08.251</pub-id></mixed-citation></ref><ref id="R10"><mixed-citation publication-type="journal"><name><surname>Sheets</surname><given-names>HD</given-names></name>, <name><surname>Gross</surname><given-names>S</given-names></name>, <name><surname>Langenburg</surname><given-names>G</given-names></name>, <name><surname>Bush</surname><given-names>PJ</given-names></name>, &#x00026; <name><surname>Bush</surname><given-names>MA</given-names></name> (<year>2013</year>). <article-title>Shape measurement tools in footwear
analysis: A statistical investigation of accidental characteristics over
time</article-title>. <source>Forensic Science International</source>,
<volume>232</volume>, <fpage>84</fpage>&#x02013;<lpage>91</lpage>.
doi:<pub-id pub-id-type="doi">10.1016/j.forsciint.2013.07.010</pub-id><pub-id pub-id-type="pmid">24053869</pub-id></mixed-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Figure 1.</label><caption><p id="P27">Five regions of the boot that were separated prior to realignment. The
outsole is the bottom part of the boot. The surface tread is the outermost part
of the outsole. The deepest part of the outsole (&#x0201c;deep sole&#x0201d;) was
used in the alignment process.</p></caption><graphic xlink:href="nihms-1014694-f0001"/></fig><fig id="F2" orientation="portrait" position="float"><label>Figure 2.</label><caption><p id="P28">Custom-built rig to securely hold boot during scanning.</p></caption><graphic xlink:href="nihms-1014694-f0002"/></fig><fig id="F3" orientation="portrait" position="float"><label>Figure 3.</label><caption><p id="P29">An example of a comparison point (surf pt 1) on the deep sole and
virtual calliper point (calliper 1) on surface tread of the mesh of one boot.
The comparison points were linked to the reference object, or the initial mesh
(light gray). Callipers were linked to the data objects, or the worn mesh, which
is shown in dark gray. The comparison point is shown as a white circle on the
deep sole and the calliper is shown with two endpoints connected by white lines.
Units: mm.</p></caption><graphic xlink:href="nihms-1014694-f0003"/></fig><fig id="F4" orientation="portrait" position="float"><label>Figure 4.</label><caption><p id="P30">Virtual calliper and comparison point locations for Boot 2. The virtual
calliper end points are shown in black with dotted lines between the two
endpoints and the comparison points are in white. An example calliper is
outlined by a white box. The first end point of the calliper is on the surface
tread and the second is on the deep sole. The second end point of the calliper
was placed within the diameter of a nearby comparison point.</p></caption><graphic xlink:href="nihms-1014694-f0004"/></fig><fig id="F5" orientation="portrait" position="float"><label>Figure 5.</label><caption><p id="P31">Misalignments due to bending in Boot 1 (a) and Boot 2 (b) after the
first wear period. The initial outsole mesh is shown in light grey and the first
wear period mesh is dark grey. After the outsole was cut into sections and
realigned, much of the misalignments were corrected, which is most evident in
the toe of Boot 1 (c) and Boot 2 (d).</p></caption><graphic xlink:href="nihms-1014694-f0005"/></fig><table-wrap id="T1" position="float" orientation="portrait"><label>Table 1.</label><caption><p id="P32">Average depth measurements from the heel, archball, ball, and toe
regions of both Boot 1 and Boot 2 (&#x003b1; = 0.05).</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1"/><th colspan="2" align="center" valign="middle" rowspan="1">Boot 1<hr/></th><th colspan="2" align="center" valign="middle" rowspan="1">Boot 2<hr/></th></tr><tr><th align="left" valign="middle" rowspan="1" colspan="1"/><th colspan="2" align="center" valign="middle" rowspan="1"><italic>n</italic>=
98<hr/></th><th colspan="2" align="center" valign="middle" rowspan="1"><italic>n</italic>=
140<hr/></th></tr><tr><th align="left" valign="middle" rowspan="1" colspan="1"/><th align="center" valign="middle" rowspan="1" colspan="1">Virtual<break/>callipers</th><th align="center" valign="middle" rowspan="1" colspan="1">Manual<break/>callipers</th><th align="center" valign="middle" rowspan="1" colspan="1">Virtual<break/>callipers</th><th align="center" valign="middle" rowspan="1" colspan="1">Manual<break/>callipers</th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">Mean</td><td align="center" valign="middle" rowspan="1" colspan="1">3.908</td><td align="center" valign="middle" rowspan="1" colspan="1">3.912</td><td align="center" valign="middle" rowspan="1" colspan="1">4.486</td><td align="center" valign="middle" rowspan="1" colspan="1">4.463</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Standard deviation</td><td align="center" valign="middle" rowspan="1" colspan="1">1.065</td><td align="center" valign="middle" rowspan="1" colspan="1">1.060</td><td align="center" valign="middle" rowspan="1" colspan="1">1.234</td><td align="center" valign="middle" rowspan="1" colspan="1">1.205</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Sample variance</td><td align="center" valign="middle" rowspan="1" colspan="1">1.135</td><td align="center" valign="middle" rowspan="1" colspan="1">1.124</td><td align="center" valign="middle" rowspan="1" colspan="1">1.523</td><td align="center" valign="middle" rowspan="1" colspan="1">1.453</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Pearson correlation</td><td align="center" valign="middle" rowspan="1" colspan="1">0.982</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">0.988</td><td align="center" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"><italic>p</italic> (<italic>T</italic>
&#x0003c; = <italic>t</italic>) two-tail</td><td align="center" valign="middle" rowspan="1" colspan="1">0.851</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">0.260</td><td align="center" valign="middle" rowspan="1" colspan="1"/></tr></tbody></table></table-wrap></floats-group></article>