<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties open_access?><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101680239</journal-id><journal-id journal-id-type="pubmed-jr-id">45119</journal-id><journal-id journal-id-type="nlm-ta">Int J Min Sci Technol</journal-id><journal-id journal-id-type="iso-abbrev">Int J Min Sci Technol</journal-id><journal-title-group><journal-title>International journal of mining science and technology</journal-title></journal-title-group><issn pub-type="ppub">2095-2686</issn></journal-meta><article-meta><article-id pub-id-type="pmid">30733889</article-id><article-id pub-id-type="pmc">6363127</article-id><article-id pub-id-type="doi">10.1016/j.ijmst.2017.11.015</article-id><article-id pub-id-type="manuscript">HHSPA998332</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Analysis of global and local stress changes in a longwall gateroad</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Tulu</surname><given-names>I.B.</given-names></name><xref ref-type="aff" rid="A1">a</xref><xref rid="CR1" ref-type="corresp">*</xref></contrib><contrib contrib-type="author"><name><surname>Esterhuizen</surname><given-names>G.S.</given-names></name><xref ref-type="aff" rid="A2">b</xref></contrib><contrib contrib-type="author"><name><surname>Gearhart</surname><given-names>D.</given-names></name><xref ref-type="aff" rid="A2">b</xref></contrib><contrib contrib-type="author"><name><surname>Klemetti</surname><given-names>T.M.</given-names></name><xref ref-type="aff" rid="A2">b</xref></contrib><contrib contrib-type="author"><name><surname>Mohamed</surname><given-names>K.M.</given-names></name><xref ref-type="aff" rid="A2">b</xref></contrib><contrib contrib-type="author"><name><surname>Su</surname><given-names>D.W.H.</given-names></name><xref ref-type="aff" rid="A2">b</xref></contrib></contrib-group><aff id="A1"><label>a</label>Department of Mining Engineering, West Virginia University, Morgantown 26505, USA</aff><aff id="A2"><label>b</label>NIOSH, Pittsburgh Mining Research Division, Pittsburgh 15216, USA</aff><author-notes><corresp id="CR1"><label>*</label>Corresponding author: <email>itulu@mail.wvu.edu</email> (I.B. Tulu).</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>14</day><month>12</month><year>2018</year></pub-date><pub-date pub-type="ppub"><month>1</month><year>2018</year></pub-date><pub-date pub-type="pmc-release"><day>05</day><month>2</month><year>2019</year></pub-date><volume>28</volume><issue>1</issue><fpage>127</fpage><lpage>135</lpage><!--elocation-id from pubmed: 10.1016/j.ijmst.2017.11.015--><permissions><license license-type="open-access"><license-p>This is an open access article under the CC BY-NC-ND license (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc-nd/4.0/">http://creativecommons.org/licenses/by-nc-nd/4.0/</ext-link>).</license-p></license></permissions><abstract id="ABS1"><p id="P1">A numerical-model-based approach was recently developed for estimating the changes in both the horizontal and vertical loading conditions induced by an approaching longwall face. In this approach, a systematic procedure is used to estimate the model&#x02019;s inputs. Shearing along the bedding planes is modeled with ubiquitous joint elements and interface elements. Coal is modeled with a newly developed coal mass model. The response of the gob is calibrated with back analysis of subsidence data and the results of previously published laboratory tests on rock fragments. The model results were verified with the subsidence and stress data recently collected from a longwall mine in the eastern United States.</p></abstract><kwd-group><kwd>Longwall mining</kwd><kwd>Gateroad design</kwd><kwd>Flac3D</kwd><kwd>Horizontal angle</kwd><kwd>Gob loading</kwd><kwd>Hollow inclusion cells</kwd></kwd-group></article-meta></front><body><sec id="S1"><label>1.</label><title>Introduction</title><p id="P2">In 2015, there were 40 longwall mines operating in the United States, each producing an average of 4.5 million tons of coal per year, and they supplied 60% of the U.S. underground coal production. This represents a substantial increase from 50% over the previous three years [<xref rid="R1" ref-type="bibr">1</xref>]. During this period, reportable roof fall rates in U.S. longwall mines also increased. Large roof falls that can block the gateroads are not only a ground-fall hazard; they can disrupt the ventilation system, block the escape ways, and increase the potential for elevated methane levels in the gob. To address these hazards, the National Institute for Occupational Safety and Health (NIOSH) Pittsburgh Mining Research Division (PMRD) is conducting research to improve the design of ground control systems in longwall gateroads.</p><p id="P3">Gateroad layout is primarily determined by the longwall pillar design. Generally, the required dimensions of the pillars around a longwall panel are determined first, which dictates the location of the gateroads relative to the mined panel. The analysis of long-wall pillar stability (ALPS) method is the most accepted design procedure in the United States [<xref rid="R2" ref-type="bibr">2</xref>]. The ALPS method accounts for local roof geology in the gateroad stability assessment by including the coal mine roof rating as an input parameter [<xref rid="R2" ref-type="bibr">2</xref>]. The key assumption in the ALPS method is that unstable pillars will result in unstable gate entries. However, experience provides examples of mines where pillar stability and gateroad stability are loosely correlated [<xref rid="R3" ref-type="bibr">3</xref>].</p><p id="P4">Gateroad support design is largely empirical, often based on a trial-and-error approach. Gateroad stability and safety can be improved by introducing an engineering-based design approach that specifically considers the rock mass and support response to changes in both the horizontal and vertical loading conditions induced by the approaching longwall face. Such complex stress changes during a longwall retreat can be evaluated with calibrated numerical models, allowing support systems to be designed that can accommodate the expected loading conditions.</p></sec><sec id="S2"><label>2.</label><title>Longwall model development and calibration</title><p id="P5">Esterhuizen et al. developed a modeling approach that can be used to provide realistic stress and deformation results along the gateroad chain pillars [<xref rid="R4" ref-type="bibr">4</xref>]. In this approach, an &#x0201c;equivalent element&#x0201d; method is used to capture the stress/strain response of the pillars and the immediate roof and floor rocks to model large-scale, three-dimensional retreat mining layouts. One limitation of this approach is that the response of the immediate roof to horizontal stress change during the retreat mining cannot be investigated because only the vertical stress is solved within the equivalent elements. Recently, this approach has been updated for estimating the changes in both the horizontal and vertical loading conditions in the immediate roof of the gateroads [<xref rid="R5" ref-type="bibr">5</xref>]. The modified approach uses standard elements to model the pillars, roof, and floor, which provides the full stress tensor, including horizontal stress components in the roof of the coal bed. In addition, interface elements are introduced between main geologic units to more accurately model shear and bending of the overburden strata.</p><sec id="S3"><label>2.1.</label><title>Pillar strength modeling</title><p id="P6">Recently at NIOSH, Mohamed et al. developed a coal material model. In this model, the peak strength of the coal is evaluated by the generalized Hoek-Brown failure criterion [<xref rid="R6" ref-type="bibr">6</xref>&#x02013;<xref rid="R8" ref-type="bibr">8</xref>]. The residual stiffness and strength are evaluated by the Fang and Harrison local degradation model [<xref rid="R9" ref-type="bibr">9</xref>]. The dilation of the coal material is defined by the Alejano and Alonso peak-dilation model [<xref rid="R9" ref-type="bibr">9</xref>,<xref rid="R10" ref-type="bibr">10</xref>].</p><p id="P7">Mohamed et al. indicated that the Mohr-Coulomb constitutive model provides a method for describing the dilation behavior of rocks, and it is available in the majority of numerical codes [<xref rid="R7" ref-type="bibr">7</xref>]. Therefore, in this model, the equivalent Mohr-Coulomb model parameters derived from the Hoek-Brown criterion are used. This model simulates the peak and post-peak behaviors of the coal material by using a strain-softening, ubiquitous joint model available in the FLAC3D software.</p><p id="P8">The input parameters used for coal in this paper are summarized in <xref rid="T1" ref-type="table">Table 1</xref>. In <xref rid="T1" ref-type="table">Table 1</xref>, &#x0201c;<italic>&#x003c3;ci</italic>&#x0201d; is the intact unconfined compressive strength of the coal, and <italic>m</italic>, <italic>s</italic> and <italic>a</italic> are the peak strength scaled parameters of coal. The parameter <italic>&#x003c3;c</italic> represents peak, and <italic>&#x003c3;cr</italic> is the residual of the field-scale unconfined compressive strength. <italic>Nd</italic> is a scaled coal degradation parameter. This degradation parameter is used to reduce the strength and stiffness of the coal from peak values to residual values in the coal model. &#x003a5;<italic>pcrit</italic> is the critical plastic shear strain that controls the rate of material degradation. The strength of the coal material is reduced until plastic shear strain reaches to this critical value. Coal material fracturing is simulated by adding an implicit cohesion-less ubiquitous joint within the material. Fractures are initiated in those elements that have plastic shear strain equal to or greater than the &#x0201c;fracture plastic shear strain&#x0201d; parameter detailed in <xref rid="T1" ref-type="table">Table 1</xref>. The coal model was originally developed to simulate the stress/strain behavior of coal pillar ribs. This model also simulates the stress/strain behavior of full coal pillars satisfactorily, as demonstrated in <xref rid="F1" ref-type="fig">Fig. 1</xref>.</p><p id="P9">To compare the stress-strain behavior of the pillars generated with the coal model of Mohamed et al. to results obtained by Esterhuizen et al., numerical models were created in which portions of the roof strata, the coal pillar, and the floor strata were simulated [<xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R7" ref-type="bibr">7</xref>]. The same boundary conditions and model geometries used by Esterhuizen et al. were modeled [<xref rid="R4" ref-type="bibr">4</xref>]. <xref rid="F1" ref-type="fig">Fig. 1</xref> shows the resulting stress-strain curves obtained from the coal models with different pillar width-to-height ratios. The stress-strain behavior presented in <xref rid="F1" ref-type="fig">Fig. 1</xref> is similar to the results published by Esterhuizen et al. [<xref rid="R4" ref-type="bibr">4</xref>]. The new coal model can simulate the fracture development in coal pillar [<xref rid="R7" ref-type="bibr">7</xref>]. Post-peak stress/strain behavior was slightly different. For the width-to-height ratios below 8, the pillars exhibit a strain-softening behavior. For the width-to-height ratios above 8, the pillars exhibit a strain-hardening behavior. The peak pillar strengths simulated by the numerical models are compared with the empirical Bieniawski pillar strength equation in <xref rid="F2" ref-type="fig">Fig. 2</xref>. The results show good agreement between the model calculations and the empirical equation.</p></sec><sec id="S4"><label>2.2.</label><title>Gob response modeling</title><p id="P10">It is important to simulate the gob response accurately to simulate the load distribution along the gateroad entries. Esterhuizen et al. indicated that gob modeling can follow two approaches: (1) explicitly model the gob formation process so that variations in geology and loading conditions can be studied, (2) implicitly model the gob compaction and load distribution to accurately model load redistribution to gateroad pillars and surrounding rock. As in Esterhuizen et al., the second approach is used in this paper to simulate the behavior of the gob [<xref rid="R4" ref-type="bibr">4</xref>].</p><p id="P11">As indicated by Pappas and Mark, laboratory tests on shale and sandstone fragments showed that the stress-strain response of caved material should follow a strain-hardening curve [<xref rid="R11" ref-type="bibr">11</xref>]. Pappas and Mark used the hyperbolic function derived by Salamon to fit test results, and they found that this function sufficiently simulates the strain-hardening gob response [<xref rid="R11" ref-type="bibr">11</xref>,<xref rid="R12" ref-type="bibr">12</xref>].
<disp-formula id="FD1"><label>(1)</label><mml:math display="block" id="M1" overflow="scroll"><mml:mrow><mml:mi>&#x003c3;</mml:mi><mml:mo>=</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>a</mml:mi><mml:mo>&#x000d7;</mml:mo><mml:mi>&#x003b5;</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mo>/</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>b</mml:mi><mml:mo>&#x02212;</mml:mo><mml:mi>&#x003b5;</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:math></disp-formula>
where <italic>&#x003c3;</italic> is the vertical gob stress, MPa; <italic>&#x003b5;</italic> the vertical gob strain, and <italic>&#x003b5;</italic> = b/2, MPa; <italic>b</italic> the maximum strain parameter related to void ratio; and <italic>a</italic> the gob stress.</p><p id="P12">Esterhuizen et al. calibrated the hyperbolic equation (<xref rid="FD1" ref-type="disp-formula">Eq. (1)</xref>) by matching the model results with subsidence profiles that were calculated from the surface deformation prediction software (SDPS) [<xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R13" ref-type="bibr">13</xref>]. To assist selecting appropriate gob parameters, they followed the same approach used by SDPS, in which the gob is characterized by the ratio of the thicknesses of &#x0201c;strong&#x0201d; and &#x0201c;weak&#x0201d; rocks in the overburden. They classified weak rocks as shales and clay stones that have a field scale uniaxial confining strength (UCS) of less than 40 MPa, while limestone, sandstone, and silt-stone have a field scale UCS above 40 MPa and would be classified as strong rocks. Esterhuizen et al. found that 44% represents the maximum vertical strain parameter b, which provides the initial bulking factor of 1.79 [<xref rid="R4" ref-type="bibr">4</xref>]. They also found four different <italic>a</italic> parameters for four gob types that were classified with a ratio of strong to weak rocks in the overburden: (1) weak (25%), (2) moderate (35%), (3) strong (50%), and (4) very strong (65%). The strong and moderate gob curves derived by Esterhuizen et al. are almost identical to laboratory best-fit curves for sandstone and shale materials that were published by Pappas and Mark [<xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R11" ref-type="bibr">11</xref>].</p><p id="P13">Su simulated the behavior of the gob which is assumed to be formed under an initial bulking factor of 1.5 based on observation of caving height in boreholes, representing a maximum vertical strain of 33% and a caving height equal to three times the mining height [<xref rid="R14" ref-type="bibr">14</xref>]. Su used this approach very successfully for many years for estimating surface subsidence and pillar stresses for a number of longwall mines [<xref rid="R15" ref-type="bibr">15</xref>]. In addition, it was found that the gob parameters used by Su give close stress-strain values to the weak/moderate overburden gob response curves published by Esterhuizen et al. up to a gob compaction of 28% [<xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R14" ref-type="bibr">14</xref>].</p><p id="P14">Maximum vertical strain is related to initial bulking factor (or initial void ratio). The average initial bulking factor of the test samples used by Pappas and Mark are: (1) 1.80 for shale, (2) 1.74 for sandstone, and (3) 1.87 for strong sandstone [<xref rid="R11" ref-type="bibr">11</xref>]. These values of the bulking factor represent fully rotated and dislocated blocks, which represents the maximum bulking potential of the broken rock. In a mine gob, the void ratio will decrease with distance above the floor [<xref rid="R16" ref-type="bibr">16</xref>]. A value of 1.5 appears to be good representation of average bulking factor.</p><p id="P15">In this paper the gob represents only the caved material and excludes fractured rock above the caved zone. Based on the above discussions and the calibration of the gob response curve with subsidence data, the gob parameters proposed by Esterhuizen et al. were modified by assuming the gob was formed under an average bulking factor of 1.5, which represents a maximum strain of 33% and a caving height equal to three times the mining height measured from the floor [<xref rid="R4" ref-type="bibr">4</xref>]. This value of the bulking factor also provides reasonable estimates of the subsidence when used in numerical models. Two values of the <italic>a</italic> parameter are suggested for strong overburden and weak overburden. <xref rid="F3" ref-type="fig">Fig. 3</xref> shows the stress-strain behavior of these two gob types and a comparison to the tests results of Pappas and Mark [<xref rid="R11" ref-type="bibr">11</xref>]. <xref rid="T2" ref-type="table">Table 2</xref> shows the gob parameters for these two curves.</p><p id="P16">In the model, strain-hardening gob behavior is simulated by updating the elastic modulus of each zone with the expected tangent modulus. The expected tangent modulus can be calculated by taking the derivative of <xref rid="FD1" ref-type="disp-formula">Eq. (1)</xref> with respect to vertical strain (<xref rid="FD2" ref-type="disp-formula">Eq. (2)</xref>). This task is performed by using the FISH option of the Flac3D software [<xref rid="R17" ref-type="bibr">17</xref>].
<disp-formula id="FD2"><label>(2)</label><mml:math display="block" id="M2" overflow="scroll"><mml:mrow><mml:mrow><mml:mrow><mml:mi>d</mml:mi><mml:mi>Q</mml:mi></mml:mrow><mml:mo>/</mml:mo><mml:mrow><mml:mi>d</mml:mi><mml:mi>Q</mml:mi></mml:mrow></mml:mrow><mml:mo>=</mml:mo><mml:mi>E</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>&#x003b5;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow><mml:mo>=</mml:mo><mml:msup><mml:mrow><mml:mrow><mml:mrow><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>a</mml:mi><mml:mo>&#x000d7;</mml:mo><mml:mi>b</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo>/</mml:mo><mml:mrow><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mi>b</mml:mi><mml:mo>&#x02212;</mml:mo><mml:mi>&#x003b5;</mml:mi></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mrow></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:math></disp-formula></p></sec><sec id="S5"><label>2.3.</label><title>Overburden properties</title><p id="P17">Esterhuizen et al. published the suggested rock elastic, intact strength and bedding strength properties for modeling large-scale coal measure rock in the United States. Some modifications and corrections were made to the data that was published by Esterhuizen et al. [<xref rid="R4" ref-type="bibr">4</xref>]. Updated properties are presented in Tables <xref rid="T3" ref-type="table">3</xref> and <xref rid="T4" ref-type="table">4</xref>.</p><p id="P18"><italic>UCS</italic> values in <xref rid="T3" ref-type="table">Table 3</xref> are laboratory scale values. The field value of the <italic>UCS</italic> is estimated by multiplying the laboratory value with 0.58 [<xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R8" ref-type="bibr">8</xref>]. Poisson&#x02019;s ratio was set to 0.25. For sandstone and shale, the elastic modulus <italic>E</italic> is estimated from <xref rid="FD3" ref-type="disp-formula">Eq. (3)</xref>, and for limestone, the elastic modulus is estimated from <xref rid="FD4" ref-type="disp-formula">Eq. (4)</xref>. These equations were driven from the regression analysis of a large number of <italic>UCS</italic> tests. In Eqs. (<xref rid="FD3" ref-type="disp-formula">3</xref>) and (<xref rid="FD4" ref-type="disp-formula">4</xref>), the <italic>UCS</italic> is the laboratory scale value in MPa and the resultant elastic modulus is in GPa.
<disp-formula id="FD3"><label>(3)</label><mml:math display="block" id="M3" overflow="scroll"><mml:mrow><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mn>0.143</mml:mn><mml:mo>&#x000d7;</mml:mo><mml:mi>UCS</mml:mi><mml:mo>+</mml:mo><mml:mn>6.16</mml:mn></mml:mrow></mml:math></disp-formula>
<disp-formula id="FD4"><label>(4)</label><mml:math display="block" id="M4" overflow="scroll"><mml:mrow><mml:mi>E</mml:mi><mml:mo>=</mml:mo><mml:mn>0.1162</mml:mn><mml:mo>&#x000d7;</mml:mo><mml:mi>UCS</mml:mi><mml:mo>+</mml:mo><mml:mn>15.24</mml:mn></mml:mrow></mml:math></disp-formula></p><p id="P19">The friction angles are determined from the database of tri-axial tests [<xref rid="R4" ref-type="bibr">4</xref>]. The friction values are also assumed to be the same in the laboratory and field scales. The cohesion values listed in <xref rid="T3" ref-type="table">Table 3</xref> are field scale values and calculated by using <xref rid="FD5" ref-type="disp-formula">Eq. (5)</xref>.
<disp-formula id="FD5"><label>(5)</label><mml:math display="block" id="M5" overflow="scroll"><mml:mrow><mml:mi>C</mml:mi><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mi>U</mml:mi><mml:mi>C</mml:mi><mml:msub><mml:mi>S</mml:mi><mml:mrow><mml:mi>f</mml:mi><mml:mi>i</mml:mi><mml:mi>e</mml:mi><mml:mi>l</mml:mi><mml:mi>d</mml:mi></mml:mrow></mml:msub><mml:mo>&#x000d7;</mml:mo><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mrow><mml:mn>1</mml:mn><mml:mo>&#x02212;</mml:mo><mml:mi>Sin</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>&#x003c6;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow><mml:mrow><mml:mn>2</mml:mn><mml:mo>&#x000d7;</mml:mo><mml:mi>C</mml:mi><mml:mi>o</mml:mi><mml:mi>s</mml:mi><mml:mrow><mml:mo stretchy="false">(</mml:mo><mml:mi>&#x003c6;</mml:mi><mml:mo stretchy="false">)</mml:mo></mml:mrow></mml:mrow></mml:mfrac></mml:mrow></mml:math></disp-formula>
where <italic>C</italic> is the field scale cohesion; <italic>&#x003c6;</italic> = the friction angle; and UCS<sub>field</sub> = UCS<sub>lab</sub> &#x000d7; 0.58.</p><p id="P20">Tensile strengths <italic>&#x003c3;<sub>t</sub></italic> are calculated by using <xref rid="FD6" ref-type="disp-formula">Eq. (6)</xref>.
<disp-formula id="FD6"><label>(6)</label><mml:math display="block" id="M6" overflow="scroll"><mml:mrow><mml:msub><mml:mi>&#x003c3;</mml:mi><mml:mi>t</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>0.1</mml:mn><mml:mo>&#x000d7;</mml:mo><mml:msub><mml:mi>UCS</mml:mi><mml:mrow><mml:mtext>field</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:math></disp-formula></p><p id="P21">The bedding strength parameters summarized in <xref rid="T4" ref-type="table">Table 4</xref> were derived by Esterhuizen, Mark and Murphy [<xref rid="R4" ref-type="bibr">4</xref>]. Bedding tensile strength was set to 10% of the field-scale UCS. Esterhuizen et al. indicated that bedding friction angles may seem to be small compared to small-scale laboratory strength tests, but the presence of weak clay materials, especially in the shale beds, can have a significant impact on the overall shear resistance of a bedding plane [<xref rid="R4" ref-type="bibr">4</xref>].</p><p id="P22">The matrix cohesion and tensile strength decreased from their peak values, given in <xref rid="T3" ref-type="table">Table 3</xref>, to a residual value of 10% of peak over 5 millistrains of plastic strain [<xref rid="R18" ref-type="bibr">18</xref>]. The matrix friction angle remains constant at the values shown in <xref rid="T3" ref-type="table">Table 3</xref>. The stress-strain behavior of the bedding planes are assumed to be elastic perfectly plastic.</p><p id="P23">Interfaces between the geological layers in the overburden were modeled with the interface elements. This is the major difference from Esterhuizen et al. [<xref rid="R4" ref-type="bibr">4</xref>]. Coulomb&#x02019;s criterion was used to define the limiting shear strength of the interfaces. As described by Su, the coefficient of friction of interfaces was set to 0.25 [<xref rid="R14" ref-type="bibr">14</xref>,<xref rid="R15" ref-type="bibr">15</xref>]. Joint shear stiffness was set to 0.5 GPa/m, and normal stiffness was set to 10 times the shear stiffness [<xref rid="R14" ref-type="bibr">14</xref>,<xref rid="R15" ref-type="bibr">15</xref>].</p></sec></sec><sec id="S6"><label>3.</label><title>Verification of the model</title><p id="P24">Case histories used by Esterhuizen, Mark and Murphy were again used to verify the updated modeling methodology and input parameters [<xref rid="R4" ref-type="bibr">4</xref>]. In addition, subsidence and vertical stress data recently collected by the Pittsburgh Mining Research Division (PMRD) from a longwall mine in West Virginia were used to verify the model results. Results of this verification study were published by Tulu et al. [<xref rid="R5" ref-type="bibr">5</xref>]. The model verification results showed that the response of coal measure rocks due to longwall mining can be simulated satisfactorily with this updated approach. In this paper, a numerical model is used for estimating the changes in both the horizontal and vertical loading conditions induced by an approaching longwall face in a West Virginia longwall mine.</p><sec id="S7"><label>3.1.</label><title>Longwall mine panel layout and geology</title><p id="P25">The geometry of the study sites can be seen in <xref rid="F4" ref-type="fig">Fig. 4a</xref>. The depth of cover throughout the mine ranges from 100 to 230 m, and the typical depth is about 180 m. The longwall panels are roughly 365 m wide by 2200 m long. The gateroad system is a three-entry with approximately center-to-center, 30-m-wide chain pillars. The mining high is approximately 2 m.</p><p id="P26">Three core holes were drilled between crosscut 42 and 43 in the number 1 entry between Panel #2 and Panel #3 (<xref rid="F4" ref-type="fig">Fig. 4b and c</xref>). One vertical hole was drilled 15 m into the floor, another vertical hole was drilled 15 m into the roof, and a 30&#x000b0; angled hole was drilled 9 m over the pillar and also into the roof. The collar locations for the core holes are at a depth of 182 m. Based on the in-mine mapping, as well as available exploration drillhole data, the geologic conditions are typical for the Allegheny Formation. The Middle Kittanning coal bed that is mined is overlain by dark gray to carbonaceous clay shale. The clay shale grades upward to gray sandy shale, dark gray sandy shale, or gray sandstone. The gray sandy silt shale and dark gray sandy silt shale beds vary in grain size and sand content, based on their proximity to the laterally correlative gray sandstone beds. Grain size and sand content will decrease as distance from the correlative sandstone beds increases [<xref rid="R19" ref-type="bibr">19</xref>].</p></sec><sec id="S8"><label>3.2.</label><title>Field measurements</title><p id="P27">There were three hollow inclusion cells installed over the panel and three installed over the pillar. The holes for the hollow inclusion cells, from outby to inby, were at 30&#x000b0;, 45&#x000b0;, and 60&#x000b0; from the horizontal, and each hole was 9 m deep (<xref rid="F4" ref-type="fig">Fig. 4c</xref>). The hollow inclusion (HI) cell in the 30&#x000b0; hole over the panel was overcored two times to get the in situ stress in the rock before either panel had mined passed. <xref rid="T5" ref-type="table">Table 5</xref> summarizes the measured principal in situ stresses. Details of this instrumentation study were published by Gearhart et al. [<xref rid="R20" ref-type="bibr">20</xref>]. In this paper, the stress changes measured by the hollow inclusion cells were compared to model calculations.</p></sec></sec><sec id="S9"><label>4.</label><title>Three dimensional model development</title><p id="P28">The overburden in this mine consists of alternating layers of shale, sandstone, and limestone. <xref rid="F5" ref-type="fig">Fig. 5</xref> shows a portion of the over-burden log. Because there is not available laboratory test data for mechanical properties of rock layers, Ferm numbers detailed on the geological log were used to assign the approximate mechanical properties for each layer. Molinda and Mark published the point load strength data for common coal measure rocks [<xref rid="R21" ref-type="bibr">21</xref>]. <xref rid="T6" ref-type="table">Table 6</xref> shows data published by Molinda and Mark who classified each rock type with Ferm numbers [<xref rid="R21" ref-type="bibr">21</xref>]. The mechanical properties of each layer are assigned as shown in Tables <xref rid="T3" ref-type="table">3</xref> and <xref rid="T4" ref-type="table">4</xref> by matching the Ferm number from the core log and data published by Molinda and Mark [<xref rid="R21" ref-type="bibr">21</xref>].</p><p id="P29">The thickness weighted average of the laboratory-scale UCS of the overburden is 54 MPa. The behavior of the gob, which is assumed to be formed under an initial bulking factor of 1.5, was simulated with the weak overburden strain-hardening gob parameters detailed in <xref rid="T2" ref-type="table">Table 2</xref>. The coal material is simulated with the material properties detailed in <xref rid="T1" ref-type="table">Table 1</xref>. In developing the three-dimensional panel scale model, two initial pseudo 2D models were developed using FLAC3D to investigate the effect of element size on the results. The first pseudo 2D model was developed using 61 different layers with thicknesses ranging from 1 to 10 m that were used to simulate the overburden. Element size in this model was 1 m. The second pseudo 2D model was developed using the same stratigraphy with element sizes ranging from 1 to 10 m to reduce the number of elements in the model. Once both pseudo 2D models were developed, the subsidence and stresses were compared (Figs. <xref rid="F6" ref-type="fig">6</xref> and <xref rid="F7" ref-type="fig">7</xref>). They were found to be similar enough to use the second pseudo model overburden geometry with larger element sizes in the full three-dimensional model. <xref rid="F6" ref-type="fig">Fig. 6</xref> shows the comparison of the subsidence results calculated by the two pseudo models and the field data. The model simulates the subsidence at the centerline of the panel within 2% to the field measurements. The shape of the subsidence curve is also satisfactory. The accuracy of the model-calculated subsidence at the centerline of the panel confirms that the model simulates the gob compaction satisfactorily for this case study.</p><sec id="S10"><label>4.1.</label><title>Comparison of the model results with field measurements and discussions</title><p id="P30">Horizontal and vertical stresses measured by the HI cells and calculated by the model were compared. Model results were queried at the same location as that of the HI cells relative to the entry, the geology, and the longwall face position. Both sets of HI cells on the pillar side and panel side gave credible results. In this paper, only the results of HI cells installed on the pillar side of the entry at 30&#x000b0;, 45&#x000b0;, and 60&#x000b0; from horizontal were compared with the model results to prevent repetition of the similar results gathered from the panel side. The horizontal stress response measured by the HI cells installed on the pillar side of the entry at 45&#x000b0; and 60&#x000b0; from horizontal are presented as averaged values because the response of these cells was similar but different from the HI cell installed at 30&#x000b0; from horizontal. Vertical stress measured by all of the HI cells are averaged because they all behaved similarly.</p><sec id="S11"><label>4.1.1.</label><title>Results for 30&#x000b0; HI cell during first panel passing</title><p id="P31"><xref rid="F8" ref-type="fig">Fig. 8</xref> shows the comparison of the horizontal stress response measured by the HI cell installed on the pillar side of the entry at 30&#x000b0; from horizontal and calculated by the model during first panel mining. The horizontal axis shows the relative distance between the instrumentation site and longwall face. Positive numbers indicate that the longwall face is outby the instrumented site. The vertical axis shows the percentage of stress change calculated with respect to the initial in situ stress value of the measured and/or calculated stress component. Solid green and red lines in <xref rid="F8" ref-type="fig">Fig. 8</xref> show the results for the HI cell. The red line represents the stress measured perpendicular to the entry, and the green line represents the stress measured parallel to the entry. Dotted blue and black lines show the model results.</p><p id="P32">When the first panel passes by the HI cell location, the magnitude of the horizontal stress perpendicular to the entry direction starts to decrease until it reaches to a value 10% less than its original magnitude. This minimum value was measured when the HI cell was 120 m inby the face. After that, its magnitude increases gradually as far as face is 550 m away from the HI cell. <xref rid="F8" ref-type="fig">Fig. 8</xref> shows that the model result for the horizontal stress perpendicular to the entry is also showing an initial 10% decrease in the magnitude, followed by an increase. However, the minimum value is calculated approximately 30 m inby the face, and the magnitude increases within 150 m and stays constant.</p><p id="P33"><xref rid="F8" ref-type="fig">Fig. 8</xref> shows that the magnitude of the horizontal stress parallel to the entry direction starts to increase gradually as the face approaches and passes the cell location. The model result for the horizontal stress parallel to the entry is also showing a similar increasing trend as shown by the measurement, but the final change in the magnitude calculated by the model is smaller than this measurement.</p><p id="P34">The reason for the difference in the results appears to be related to the time-dependent response of the rock mass, which means that stress change happens with time and is not solely based on the location of the advancing longwall face. However, the model results are calculated with a static solution, therefore, time-dependent effects are not simulated. Model results only depend on the distance between the face and the monitoring instruments.</p></sec><sec id="S12"><label>4.1.2.</label><title>Results for the 45&#x000b0; and 60&#x000b0; HI cells during first panel passing</title><p id="P35"><xref rid="F9" ref-type="fig">Fig. 9</xref> shows the average change in horizontal stresses measured by two HI cells, installed on the pillar side of the entry at 45&#x000b0; and 60&#x000b0; from horizontal (<xref rid="F4" ref-type="fig">Fig.4</xref>), and comparable model results. The HI cell measurements follow similar trends as in <xref rid="F8" ref-type="fig">Fig. 8</xref>. The magnitude of horizontal stress change calculated by the model parallel to the entry is approximately 20% of the in situ value, which is similar to the field measurement. However, the model calculates a gradual increase in horizontal stress perpendicular to the entry, which contradicts with the field measurement.</p><p id="P36">The difference in the stress magnitude perpendicular to the entry may be related to the fact that the geology of the roof in the model consists of uniform strata over the entire longwall panel. However, the geological model developed from the core-hole data showed that the thickness of each stratum can change rapidly and strata are not uniform. There is a strong limestone stratum on the roof which is very close to the HI cells, and its thickness and height from the roof can vary within a distance of 10 m, based on the core-hole data obtained at the monitoring site. The core-hole data over the extent of the longwall panel is too widely spaced to identify local variations of the limestone bed. The difference between the uniform geology in the model and the actual geology might create the difference between the model results and HI cells measurements.</p></sec><sec id="S13"><label>4.1.3.</label><title>Results for vertical stress changes during first panel passing</title><p id="P37"><xref rid="F10" ref-type="fig">Fig. 10</xref> shows the average vertical stresses measured by three HI cells, installed on the pillar side of the entry at 30&#x000b0;, 45&#x000b0;, and 60&#x000b0; from horizontal and comparable model results. Vertical stress measured by the HI cells increased by 44% of its initial value. The vertical stress measured by the HI cells started to increase when the face was approximately 180 m inby the HI cells and continued to increase until the face was 480 m outby the HI cells. Vertical stress calculated by the model increased by 32% of its initial value. Model results showed that vertical stress started to increase when the face was approximately 30 m inby the HI cells and continued to increase until the face was 120 m outby the measurement location.</p><p id="P38">The difference between the vertical stress measurements and model results appears to be related to the time-dependent response of the rock mass measured by the HI cells, but not included in the model. However, the magnitude and general trend of the vertical stress predicted by the model is similar to the field measurements.</p></sec><sec id="S14"><label>4.1.4.</label><title>Results for 30&#x000b0; HI cell during second panel passing</title><p id="P39"><xref rid="F11" ref-type="fig">Fig. 11</xref> shows the comparison of the horizontal stress response measured by the HI cell installed on the pillar 30&#x000b0; from horizontal and calculated by the model during the second panel mining. Both horizontal stresses measured by the HI cell stayed constant until the face is near the HI cell. After that, the horizontal stress parallel to the entry started to increase and, perpendicular to entry, started to decrease. The model results also showed similar trends. However, the model results showed a gradual increase of horizontal stresses when the instrument location was outby the face. In addition, when the face was near the instrumented location, horizontal stresses parallel to entry started to increase with a higher slope than the measurement. Similarly, horizontal stress perpendicular to the entry started to drop with a higher slope than measured.</p><p id="P40">In this case, the model calculated horizontal stress changes that were again more rapid as compared to HI cell measurements. The HI cells indicated that there is a delayed response of the rock mass to changes in the longwall face position. Time-dependent behavior is not included in the models. The model response only depends on the relative location of the cells with respect to the longwall face.</p></sec><sec id="S15"><label>4.1.5.</label><title>Results for 45&#x000b0; and 60&#x000b0; HI cells during second panel passing</title><p id="P41"><xref rid="F12" ref-type="fig">Fig. 12</xref> shows the comparison of the average horizontal stress response measured by the HI cells installed on the pillar 45&#x000b0; and 60&#x000b0; from horizontal and calculated by the model during the second panel mining. Both horizontal stresses measured by the HI cells stayed constant until the face is near the monitoring instruments. After that, both stresses started to increase. The model results showed a gradual increase compared to measurements for stress calculated perpendicular to the entry. The stress calculated parallel to the entry decreased gradually from its peak when the instruments&#x02019; location is inby the face.</p><p id="P42">There was a significant difference between the measured and model results for the horizontal stress perpendicular to the entry after the panel had passed the instrument site. The difference may be related to the slower time-dependent response of the rock mass compared to the instantaneous response of the model. A further contributing factor may be the difference between the uniform geology assumed in the model and the effect of unknown variations in the actual geology.</p></sec><sec id="S16"><label>4.1.6.</label><title>Average results for vertical stress during second panel passing</title><p id="P43"><xref rid="F13" ref-type="fig">Fig. 13</xref> shows the comparison of the average vertical stress response measured by the HI cells installed on the pillar at 30&#x000b0;, 45&#x000b0;, and 60&#x000b0; from horizontal and calculated by the model during the second panel mining. The vertical stress measured by the HI cells increased more than 2 times of its initial value when the face is approximately 15 m outby the HI cells. Vertical stress calculated by the model increased 2.5 times of its initial value at the same point.</p></sec></sec><sec id="S17"><label>4.2.</label><title>Discussion</title><p id="P44">During the first panel mining, the HI cell data showed that the horizontal stress perpendicular to the entry reduced from its original value, and the horizontal stress measured parallel to the entry increased. The model results also captured this behavior. This means that after the first panel passed, the stress was oriented in a more favorable direction with respect to the entries and in a less favorable direction for the crosscuts.</p><p id="P45">During the second panel mining, the horizontal stress that measured parallel to the entry started to increase and that perpendicular to entry started to decrease. This means that after the second panel passed, the stress was oriented in an even more favorable direction with respect to the entries compared to the situation after passing of the first panel.</p><p id="P46">The HI-cell measurements also provided some insight into the height of the caved zone over the longwall panel. The average horizontal stresses measured by the HI cells installed at 45&#x000b0; and 60&#x000b0; over the pillar started to increase as the face passed the instruments. The horizontal stress perpendicular to the entry increased more than the horizontal stress parallel to entry. The 30&#x000b0; cell did not indicate a similar change in stress. This response can be explained if the HI cells are located above the stress shadow of the caved zone, and stress is transferred to the upper strata that has not caved yet. It, therefore, appears to indicate that the height of caving was between 4.5 and 6 m above the roof line, which verifies that the bulking factor of 1.5 is a good approximation for modeling the height of the caved rock.</p></sec></sec><sec id="S18"><label>5.</label><title>Conclusions</title><p id="P47">This paper summarizes and verifies an updated approach for panel scale modeling of longwall extraction with subsidence/stress data recently collected from a longwall mine in the eastern United States. The model results show that the response of coal measure rocks due to longwall mining can be simulated satisfactorily with this updated approach. The paper also provides a basic set of input data and a modeling approach for overburden rocks, coal material, and gob material.</p><p id="P48">There are some differences between the measurements and model results. The HI cell measurements demonstrated that there is a delayed, time-dependent response of the rock mass to changes in the mining geometry. However, the model did not include time-dependent effects. The results are calculated with a static solution that assumes instantaneous response of the rock mass to changes in the mining geometry. The model results are only dependent on the relative distance between the face and the instruments. In addition, the model assumes uniform geology over the longwall panels, but in reality the geology of the roof can change over short distances. The spacing of the core holes is insufficient to identify these local changes in geology. These differences between the real world and the model approximation are likely to have contributed to the difference between the model results and HI cell measurements.</p><p id="P49">During the first panel mining, the measurements and model results showed that the horizontal stress measured perpendicular to the entry reduced from its original value and the horizontal stress measured parallel to the entry increased. This means that, after the first panel passed, the stress was oriented in a more favorable direction with respect to the entries, and less favorable for the crosscuts. During the second panel mining, measurement and model results showed that the stress was oriented in an even more favorable direction with respect to entries compared to the situation after passing of the first panel.</p><p id="P50">The elevated horizontal stress measured inby the face by the 45&#x000b0; and 60&#x000b0; HI cells appeared to indicate that the height of the caved zone extended less than 4.5 m above the roof line. This observation seems to confirm that the bulking factor of 1.5 is a reasonable value for estimating the height of the caved zone.</p></sec></body><back><fn-group><fn id="FN1"><p id="P51" content-type="publisher-disclaimer">Disclaimer</p><p id="P52" content-type="publisher-disclaimer">The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health (NIOSH). Mention of any company name, product, or software does not constitute endorsement by NIOSH.</p></fn></fn-group><ref-list><title>References</title><ref id="R1"><label>[1]</label><mixed-citation publication-type="confproc"><name><surname>Sears</surname><given-names>MM</given-names></name>, <name><surname>Tulu</surname><given-names>IB</given-names></name>, <name><surname>Esterhuizen</surname><given-names>GS</given-names></name>. <source>Overview of Current Longwall gateroad support practices</source>. In: <conf-name>Proceedings of the society for, mining, metallurgy and exploration, inc., annual conference</conf-name>, <conf-loc>Denver, Colorado</conf-loc>.</mixed-citation></ref><ref id="R2"><label>[2]</label><mixed-citation publication-type="journal"><name><surname>Mark</surname><given-names>C</given-names></name>
<article-title>Analysis of longwall pillar stability (ALPS): an update</article-title>. In: <source>Proceedings of the workshop on coal pillar mechanics and design</source>. <comment>Bureau of Mines IC 9315</comment>; <year>1992</year> p. <fpage>238</fpage>&#x02013;<lpage>49</lpage>.</mixed-citation></ref><ref id="R3"><label>[3]</label><mixed-citation publication-type="confproc"><name><surname>Su</surname><given-names>DWH</given-names></name>, <name><surname>Draskovich</surname><given-names>DJ</given-names></name>, <name><surname>Thomas</surname><given-names>EP</given-names></name>. <source>Pillar design and roof support for controlling longwall headgate subject to high horizontal stresses</source>. In: <conf-name>Proceedings of the 22nd international conference on ground control in mining</conf-name>, <conf-loc>Morgantown</conf-loc>, <conf-date>25&#x02013;27 July 2003</conf-date> p. <fpage>1</fpage>&#x02013;<lpage>10</lpage>.</mixed-citation></ref><ref id="R4"><label>[4]</label><mixed-citation publication-type="confproc"><name><surname>Esterhuizen</surname><given-names>GS</given-names></name>, <name><surname>Mark</surname><given-names>C</given-names></name>, <name><surname>Murphy</surname><given-names>MM</given-names></name>. <source>Numerical model calibration for simulating coal pillars, gob and overburden response</source>. In: <conf-name>Proceedings of the 29th international conference on ground control in mining</conf-name>, <conf-loc>Morgantown</conf-loc>, <conf-date>25&#x02013;27 July 2010</conf-date> p. <fpage>1</fpage>&#x02013;<lpage>12</lpage>.</mixed-citation></ref><ref id="R5"><label>[5]</label><mixed-citation publication-type="confproc"><name><surname>Tulu</surname><given-names>IB</given-names></name>, <name><surname>Esterhuizen</surname><given-names>GS</given-names></name>, <name><surname>Mohamed</surname><given-names>KM</given-names></name>, <name><surname>Klemetti</surname><given-names>TM</given-names></name>. <source>Verification of a calibrated longwall model with field measurements</source>. In: <conf-name>51st US rock mechanics/geomechanics symposium</conf-name>
<conf-loc>American Rock Mechanics Association</conf-loc>; <year>2017</year>.</mixed-citation></ref><ref id="R6"><label>[6]</label><mixed-citation publication-type="confproc"><name><surname>Mohamed</surname><given-names>KM</given-names></name>, <name><surname>Tulu</surname><given-names>IB</given-names></name>, <name><surname>Klemetti</surname><given-names>T</given-names></name>. <source>Numerical simulation of deformation and failure process of coal-mass</source>. In: <conf-name>49th US rock mechanics/geomechanics symposium</conf-name>
<conf-loc>American Rock Mechanics Association</conf-loc>; <year>2015</year>.</mixed-citation></ref><ref id="R7"><label>[7]</label><mixed-citation publication-type="confproc"><name><surname>Mohamed</surname><given-names>KM</given-names></name>, <name><surname>Tulu</surname><given-names>IB</given-names></name>, <name><surname>Murphy</surname><given-names>MM</given-names></name>. <source>Numerical model calibration for simulating coal ribs</source>. In: <conf-name>Proceedings of the society for, mining, metallurgy and exploration, inc., annual conference</conf-name>, <conf-loc>Phoenix, Arizona</conf-loc>.</mixed-citation></ref><ref id="R8"><label>[8]</label><mixed-citation publication-type="book"><name><surname>Hoek</surname><given-names>E</given-names></name>, <name><surname>Brown</surname><given-names>ET</given-names></name>. <source>Underground excavations in rock</source>. <publisher-loc>London</publisher-loc>: <publisher-name>Inst. Min. Metallurgy</publisher-name>; <year>1980</year> p. <fpage>527</fpage>.</mixed-citation></ref><ref id="R9"><label>[9]</label><mixed-citation publication-type="journal"><name><surname>Fang</surname><given-names>Z</given-names></name>, <name><surname>Harrison</surname><given-names>JP</given-names></name>. <article-title>Development of a local degradation approach to the modeling of brittle fracture of heterogeneous rocks</article-title>. <source>Int J Rock Mech Min</source>
<year>2002</year>;<volume>39</volume>:<fpage>443</fpage>&#x02013;<lpage>57</lpage>.</mixed-citation></ref><ref id="R10"><label>[10]</label><mixed-citation publication-type="journal"><name><surname>Alejano</surname><given-names>LR</given-names></name>, <name><surname>Alonso</surname><given-names>E</given-names></name>. <article-title>Considerations of the dilatancy angle in rocks and rock masses</article-title>. <source>Int J Rock Mech Min</source>
<year>2005</year>;<volume>42</volume>(<issue>4</issue>):<fpage>481</fpage>&#x02013;<lpage>507</lpage>.</mixed-citation></ref><ref id="R11"><label>[11]</label><mixed-citation publication-type="book"><name><surname>Pappas</surname><given-names>DM</given-names></name>, <name><surname>Mark</surname><given-names>C</given-names></name>. <source>Behavior of simulated gob material</source>. <publisher-name>U.S. Bureau of Mines</publisher-name>; <year>1993</year>
<fpage>RI 9458</fpage>.</mixed-citation></ref><ref id="R12"><label>[12]</label><mixed-citation publication-type="confproc"><name><surname>Salamon</surname><given-names>MDG</given-names></name>. <source>Mechanism of caving in longwall coal mining</source>. In: <conf-name>Proceedings of the 21th U.S. rock mechanics symposium</conf-name>, <conf-loc>Denver CO. A.A. Balkema</conf-loc>; <year>1990</year> p. <fpage>161</fpage>&#x02013;<lpage>8</lpage>.</mixed-citation></ref><ref id="R13"><label>[13]</label><mixed-citation publication-type="confproc"><name><surname>Newman</surname><given-names>DA</given-names></name>, <name><surname>Agioutantis</surname><given-names>Z</given-names></name>, <name><surname>Karmis</surname><given-names>M</given-names></name>. <source>SDPS for windows: an integrated approach to ground deformation prediction</source>. In: <conf-name>Proceedings of the 20th international conference on ground control in mining</conf-name>, <conf-loc>Morgantown</conf-loc>, <conf-date>25&#x02013;27 July 2001</conf-date> p. <fpage>157</fpage>&#x02013;<lpage>62</lpage>.</mixed-citation></ref><ref id="R14"><label>[14]</label><mixed-citation publication-type="confproc"><name><surname>Su</surname><given-names>DWH</given-names></name>. <source>Finite Element Modeling of Subsidence induced by underground coal mining: the influence of material nonlinearity and shearing along existing planes of weakness</source>. In: <conf-name>Proceedings of the 10th international conference on ground control in mining</conf-name>, <conf-loc>Morgantown</conf-loc>, <conf-date>25&#x02013;27 July 1991</conf-date> p. <fpage>287</fpage>&#x02013;<lpage>300</lpage>.</mixed-citation></ref><ref id="R15"><label>[15]</label><mixed-citation publication-type="journal"><name><surname>Su</surname><given-names>DWH</given-names></name>. <source>Personal communications</source>; <year>2016</year>.</mixed-citation></ref><ref id="R16"><label>[16]</label><mixed-citation publication-type="confproc"><name><surname>Esterhuizen</surname><given-names>GS</given-names></name>, <name><surname>Karacan</surname><given-names>C</given-names></name>. <source>A methodology for determining gob permeability distributions and its application to reservoir modeling of coal mine longwalls</source>. In: <conf-name>Proceedings of the society for, mining, metallurgy and exploration, inc., annual conference</conf-name>, <conf-loc>Denver, Colorado</conf-loc>.</mixed-citation></ref><ref id="R17"><label>[17]</label><mixed-citation publication-type="book"><collab>Itasca Consulting Group</collab>. <source>Flac3D User&#x02019;s Guide, Version 5.01</source>, <publisher-loc>Minnesota</publisher-loc>; <year>2003</year>.</mixed-citation></ref><ref id="R18"><label>[18]</label><mixed-citation publication-type="journal"><name><surname>Zipf</surname><given-names>RK</given-names></name>. <article-title>Numerical modeling procedures for practical coal mine design</article-title>. <source>Proceedings of the international workshop on rock mass classification in underground mine design, NIOSH IC</source>
<year>2007</year>;<volume>9498</volume>:<fpage>153</fpage>&#x02013;<lpage>62</lpage>.</mixed-citation></ref><ref id="R19"><label>[19]</label><mixed-citation publication-type="book"><name><surname>Slaker</surname><given-names>B</given-names></name>, <name><surname>Murphy</surname><given-names>M</given-names></name>, <name><surname>Iannacchione</surname><given-names>N</given-names></name>. <chapter-title>Report on geological and mechanical properties of B-UP, B-DOWN, and P30</chapter-title>
<source>PMRD internal report</source>, <publisher-loc>Pittsburgh, PA</publisher-loc>; <year>2016</year> p. <fpage>50</fpage>.</mixed-citation></ref><ref id="R20"><label>[20]</label><mixed-citation publication-type="confproc"><name><surname>Gearhart</surname><given-names>D</given-names></name>, <name><surname>Esterhuizen</surname><given-names>G</given-names></name>, <name><surname>Tulu</surname><given-names>IB</given-names></name>. In: <source>Proceedings of the 36th international conference on ground control in mining</source>, <conf-loc>Morgantown</conf-loc>, <conf-date>24&#x02013;27 July 2017</conf-date>.</mixed-citation></ref><ref id="R21"><label>[21]</label><mixed-citation publication-type="confproc"><name><surname>Molinda</surname><given-names>GM</given-names></name>, <name><surname>Mark</surname><given-names>C</given-names></name>. <source>Rating the strength of coal mine roof rocks</source>. <conf-name>Rock mechanics tools and techniques: in proceedings of the 2nd North American rock mechanics symposium: NARMS&#x02019;96, a regional conference of ISRM</conf-name>, <conf-loc>Montr&#x000e9;al, Qu&#x000e9;bec, Canada</conf-loc>, <conf-date>19&#x02013;21 June 1996</conf-date>, vol. <volume>1</volume>
<conf-loc>US: Taylor &#x00026; Francis</conf-loc>; <comment>1996</comment> p. <fpage>413</fpage>.</mixed-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Fig. 1.</label><caption><p id="P53">Stress-strain curves obtained from a calibrated coal model.</p></caption><graphic xlink:href="nihms-998332-f0001"/></fig><fig id="F2" orientation="portrait" position="float"><label>Fig. 2.</label><caption><p id="P54">Pillar strength results obtained by numerical models after calibrating the models to the empirical pillar strength equation.</p></caption><graphic xlink:href="nihms-998332-f0002"/></fig><fig id="F3" orientation="portrait" position="float"><label>Fig. 3.</label><caption><p id="P55">Stress-strain behavior of the two gob types and a comparison to the tests results.</p></caption><graphic xlink:href="nihms-998332-f0003"/></fig><fig id="F4" orientation="portrait" position="float"><label>Fig. 4.</label><caption><p id="P56">Field monitoring location.</p></caption><graphic xlink:href="nihms-998332-f0004"/></fig><fig id="F5" orientation="portrait" position="float"><label>Fig. 5.</label><caption><p id="P57">A portion of the overburden log.</p></caption><graphic xlink:href="nihms-998332-f0005"/></fig><fig id="F6" orientation="portrait" position="float"><label>Fig. 6.</label><caption><p id="P58">Comparison of the subsidence measurements with model results.</p></caption><graphic xlink:href="nihms-998332-f0006"/></fig><fig id="F7" orientation="portrait" position="float"><label>Fig. 7.</label><caption><p id="P59">Model-calculated vertical stress distribution.</p></caption><graphic xlink:href="nihms-998332-f0007"/></fig><fig id="F8" orientation="portrait" position="float"><label>Fig. 8.</label><caption><p id="P60">Horizontal stress response of 30&#x000b0; HI cell during first panel mining.</p></caption><graphic xlink:href="nihms-998332-f0008"/></fig><fig id="F9" orientation="portrait" position="float"><label>Fig. 9.</label><caption><p id="P61">Average horizontal stress response of 45 and 60&#x000b0; HI cells during first panel mining.</p></caption><graphic xlink:href="nihms-998332-f0009"/></fig><fig id="F10" orientation="portrait" position="float"><label>Fig. 10.</label><caption><p id="P62">Average vertical stresses response by three HI cells during first panel mining.</p></caption><graphic xlink:href="nihms-998332-f0010"/></fig><fig id="F11" orientation="portrait" position="float"><label>Fig. 11.</label><caption><p id="P63">Horizontal stress response of 30&#x000b0; HI cell during second panel mining.</p></caption><graphic xlink:href="nihms-998332-f0011"/></fig><fig id="F12" orientation="portrait" position="float"><label>Fig. 12.</label><caption><p id="P64">Average horizontal stress response of 45&#x000b0; and 60&#x000b0; HI cells during second panel mining.</p></caption><graphic xlink:href="nihms-998332-f0012"/></fig><fig id="F13" orientation="portrait" position="float"><label>Fig. 13.</label><caption><p id="P65">Average vertical stress response by three HI cells during second panel mining.</p></caption><graphic xlink:href="nihms-998332-f0013"/></fig><table-wrap id="T1" position="float" orientation="landscape"><label>Table 1</label><caption><p id="P66">Input parameters for coal material.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th colspan="2" align="left" valign="top" rowspan="1">Elastic property<hr/></th><th colspan="6" align="left" valign="top" rowspan="1">Strength parameter<hr/></th><th colspan="2" align="left" valign="top" rowspan="1">Degradation parameter<hr/></th><th align="left" valign="top" rowspan="1" colspan="1">Ubiquitous joint friction angle</th><th align="left" valign="top" rowspan="1" colspan="1">Fracture plastic shear strain</th></tr><tr><th align="left" valign="top" rowspan="1" colspan="1">Modulus (GPa)</th><th align="left" valign="top" rowspan="1" colspan="1">Poisson&#x02019;s ratio</th><th align="left" valign="top" rowspan="1" colspan="1"><italic>&#x003c3;ci</italic> (MPa)</th><th align="left" valign="top" rowspan="1" colspan="1"><italic>m</italic></th><th align="left" valign="top" rowspan="1" colspan="1"><italic>s</italic></th><th align="left" valign="top" rowspan="1" colspan="1"><italic>a</italic></th><th align="left" valign="top" rowspan="1" colspan="1"><italic>&#x003c3;cr</italic> (MPa)</th><th align="left" valign="top" rowspan="1" colspan="1"><italic>&#x003c3;c</italic> (MPa)</th><th align="left" valign="top" rowspan="1" colspan="1"><italic>Nd</italic></th><th align="left" valign="top" rowspan="1" colspan="1">&#x003a5;<italic>pcrit</italic></th><th align="left" valign="top" rowspan="1" colspan="1"/><th align="left" valign="top" rowspan="1" colspan="1"/></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">3</td><td align="left" valign="middle" rowspan="1" colspan="1">0.25</td><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">1.52</td><td align="left" valign="middle" rowspan="1" colspan="1">0.013</td><td align="left" valign="middle" rowspan="1" colspan="1">0.5</td><td align="left" valign="middle" rowspan="1" colspan="1">0.3</td><td align="left" valign="middle" rowspan="1" colspan="1">2.28</td><td align="left" valign="middle" rowspan="1" colspan="1">0.503</td><td align="left" valign="middle" rowspan="1" colspan="1">0.26</td><td align="left" valign="middle" rowspan="1" colspan="1">25</td><td align="left" valign="middle" rowspan="1" colspan="1">0.0275</td></tr></tbody></table></table-wrap><table-wrap id="T2" position="float" orientation="portrait"><label>Table 2</label><caption><p id="P67">Parameters for modeling various gob types.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1">Overburden type</th><th align="left" valign="middle" rowspan="1" colspan="1"><italic>a</italic> (MPa)</th><th align="left" valign="middle" rowspan="1" colspan="1"><italic>b</italic></th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">Weak</td><td align="left" valign="middle" rowspan="1" colspan="1">3.00</td><td align="left" valign="middle" rowspan="1" colspan="1">0.33</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Strong</td><td align="left" valign="middle" rowspan="1" colspan="1">7.24</td><td align="left" valign="middle" rowspan="1" colspan="1">0.33</td></tr></tbody></table></table-wrap><table-wrap id="T3" position="float" orientation="landscape"><label>Table 3</label><caption><p id="P68">Suggested intact rock properties.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1">Type</th><th align="left" valign="middle" rowspan="1" colspan="1"><italic>UCS</italic> (MPa)</th><th align="left" valign="middle" rowspan="1" colspan="1"><italic>E</italic> (GPa)</th><th align="left" valign="middle" rowspan="1" colspan="1">Friction angle (&#x000b0;)</th><th align="left" valign="middle" rowspan="1" colspan="1">Cohesion (MPa)</th><th align="left" valign="middle" rowspan="1" colspan="1">Tensile strength (MPa)</th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">Limestone</td><td align="left" valign="middle" rowspan="1" colspan="1">140</td><td align="left" valign="middle" rowspan="1" colspan="1">31.51</td><td align="left" valign="middle" rowspan="1" colspan="1">42</td><td align="left" valign="middle" rowspan="1" colspan="1">18.08</td><td align="left" valign="middle" rowspan="1" colspan="1">8.12</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">100</td><td align="left" valign="middle" rowspan="1" colspan="1">26.86</td><td align="left" valign="middle" rowspan="1" colspan="1">42</td><td align="left" valign="middle" rowspan="1" colspan="1">12.91</td><td align="left" valign="middle" rowspan="1" colspan="1">5.80</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">80</td><td align="left" valign="middle" rowspan="1" colspan="1">24.54</td><td align="left" valign="middle" rowspan="1" colspan="1">40</td><td align="left" valign="middle" rowspan="1" colspan="1">10.82</td><td align="left" valign="middle" rowspan="1" colspan="1">4.64</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">120</td><td align="left" valign="middle" rowspan="1" colspan="1">23.32</td><td align="left" valign="middle" rowspan="1" colspan="1">42</td><td align="left" valign="middle" rowspan="1" colspan="1">15.49</td><td align="left" valign="middle" rowspan="1" colspan="1">6.96</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">100</td><td align="left" valign="middle" rowspan="1" colspan="1">20.46</td><td align="left" valign="middle" rowspan="1" colspan="1">40</td><td align="left" valign="middle" rowspan="1" colspan="1">13.52</td><td align="left" valign="middle" rowspan="1" colspan="1">5.80</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">80</td><td align="left" valign="middle" rowspan="1" colspan="1">17.60</td><td align="left" valign="middle" rowspan="1" colspan="1">37</td><td align="left" valign="middle" rowspan="1" colspan="1">11.57</td><td align="left" valign="middle" rowspan="1" colspan="1">4.64</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">60</td><td align="left" valign="middle" rowspan="1" colspan="1">14.74</td><td align="left" valign="middle" rowspan="1" colspan="1">35</td><td align="left" valign="middle" rowspan="1" colspan="1">9.06</td><td align="left" valign="middle" rowspan="1" colspan="1">3.48</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">40</td><td align="left" valign="middle" rowspan="1" colspan="1">11.88</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">6.70</td><td align="left" valign="middle" rowspan="1" colspan="1">2.32</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Shale</td><td align="left" valign="middle" rowspan="1" colspan="1">80</td><td align="left" valign="middle" rowspan="1" colspan="1">17.60</td><td align="left" valign="middle" rowspan="1" colspan="1">32</td><td align="left" valign="middle" rowspan="1" colspan="1">12.86</td><td align="left" valign="middle" rowspan="1" colspan="1">4.64</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">60</td><td align="left" valign="middle" rowspan="1" colspan="1">14.74</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">10.05</td><td align="left" valign="middle" rowspan="1" colspan="1">3.48</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">40</td><td align="left" valign="middle" rowspan="1" colspan="1">11.88</td><td align="left" valign="middle" rowspan="1" colspan="1">25</td><td align="left" valign="middle" rowspan="1" colspan="1">7.39</td><td align="left" valign="middle" rowspan="1" colspan="1">2.32</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">10.45</td><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">6.09</td><td align="left" valign="middle" rowspan="1" colspan="1">1.74</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">9.02</td><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">4.06</td><td align="left" valign="middle" rowspan="1" colspan="1">1.16</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">10</td><td align="left" valign="middle" rowspan="1" colspan="1">7.59</td><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">2.03</td><td align="left" valign="middle" rowspan="1" colspan="1">0.58</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">6.88</td><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">1.02</td><td align="left" valign="middle" rowspan="1" colspan="1">0.29</td></tr></tbody></table></table-wrap><table-wrap id="T4" position="float" orientation="portrait"><label>Table 4</label><caption><p id="P69">Suggested bedding strength properties.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1">Type</th><th align="left" valign="middle" rowspan="1" colspan="1">Cohesion (MPa)</th><th align="left" valign="middle" rowspan="1" colspan="1">Friction (&#x000b0;)</th><th align="left" valign="middle" rowspan="1" colspan="1">Tension (MPa)</th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">Limestone</td><td align="left" valign="middle" rowspan="1" colspan="1">9.47</td><td align="left" valign="middle" rowspan="1" colspan="1">32</td><td align="left" valign="middle" rowspan="1" colspan="1">0.81</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">7.55</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">0.58</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">6.70</td><td align="left" valign="middle" rowspan="1" colspan="1">28</td><td align="left" valign="middle" rowspan="1" colspan="1">0.46</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">8.11</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">0.70</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">6.76</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">0.58</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">6.04</td><td align="left" valign="middle" rowspan="1" colspan="1">27</td><td align="left" valign="middle" rowspan="1" colspan="1">0.46</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">4.53</td><td align="left" valign="middle" rowspan="1" colspan="1">25</td><td align="left" valign="middle" rowspan="1" colspan="1">0.35</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">3.35</td><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">0.23</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">Shale</td><td align="left" valign="middle" rowspan="1" colspan="1">2.96</td><td align="left" valign="middle" rowspan="1" colspan="1">10</td><td align="left" valign="middle" rowspan="1" colspan="1">0.46</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">2.44</td><td align="left" valign="middle" rowspan="1" colspan="1">7</td><td align="left" valign="middle" rowspan="1" colspan="1">0.35</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">1.78</td><td align="left" valign="middle" rowspan="1" colspan="1">7</td><td align="left" valign="middle" rowspan="1" colspan="1">0.23</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">0.50</td><td align="left" valign="middle" rowspan="1" colspan="1">7</td><td align="left" valign="middle" rowspan="1" colspan="1">0.17</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">0.30</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">0.12</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">0.20</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">0.06</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">0.10</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">0.03</td></tr></tbody></table></table-wrap><table-wrap id="T5" position="float" orientation="landscape"><label>Table 5</label><caption><p id="P70">HI-cell overcoring 3D in situ measurements.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="top" rowspan="1" colspan="1">Overcore no.</th><th colspan="3" align="left" valign="middle" rowspan="1">Principal stress (MPa)<hr/></th><th colspan="2" align="left" valign="middle" rowspan="1">Maximum principal stress direction<hr/></th></tr><tr><th align="left" valign="middle" rowspan="1" colspan="1"/><th align="left" valign="middle" rowspan="1" colspan="1">Maximum</th><th align="left" valign="middle" rowspan="1" colspan="1">Intermediate</th><th align="left" valign="middle" rowspan="1" colspan="1">Minimum</th><th align="left" valign="middle" rowspan="1" colspan="1">Dip (&#x000b0;)</th><th align="left" valign="middle" rowspan="1" colspan="1">Azimuth (&#x000b0;)</th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">1</td><td align="left" valign="middle" rowspan="1" colspan="1">6.52</td><td align="left" valign="middle" rowspan="1" colspan="1">5.47</td><td align="left" valign="middle" rowspan="1" colspan="1">4.14</td><td align="left" valign="middle" rowspan="1" colspan="1">13</td><td align="left" valign="middle" rowspan="1" colspan="1">117</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">2</td><td align="left" valign="middle" rowspan="1" colspan="1">8.28</td><td align="left" valign="middle" rowspan="1" colspan="1">6.58</td><td align="left" valign="middle" rowspan="1" colspan="1">3.47</td><td align="left" valign="middle" rowspan="1" colspan="1">4</td><td align="left" valign="middle" rowspan="1" colspan="1">290</td></tr></tbody></table></table-wrap><table-wrap id="T6" position="float" orientation="landscape"><label>Table 6</label><caption><p id="P71">Common coal measure roof rocks and their point load strength properties [<xref rid="R21" ref-type="bibr">21</xref>].</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="top" rowspan="1" colspan="1">Ferm no.</th><th align="left" valign="top" rowspan="1" colspan="1">Description</th><th align="left" valign="top" rowspan="1" colspan="1">Axial strength (MPa)</th><th colspan="3" align="left" valign="top" rowspan="1">Diametric strength (MPa)<hr/></th><th align="left" valign="top" rowspan="1" colspan="1">Anisotropy</th><th align="left" valign="top" rowspan="1" colspan="1">State</th><th align="left" valign="top" rowspan="1" colspan="1">UR</th></tr><tr><th align="left" valign="top" rowspan="1" colspan="1"/><th align="left" valign="top" rowspan="1" colspan="1"/><th align="left" valign="top" rowspan="1" colspan="1">Average</th><th align="left" valign="top" rowspan="1" colspan="1">Std.</th><th align="left" valign="top" rowspan="1" colspan="1">Average</th><th align="left" valign="top" rowspan="1" colspan="1">Std.</th><th align="left" valign="top" rowspan="1" colspan="1"/><th align="left" valign="top" rowspan="1" colspan="1"/><th align="left" valign="top" rowspan="1" colspan="1"/></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">14</td><td align="left" valign="middle" rowspan="1" colspan="1">Slumped sandy shale</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">PA</td><td align="left" valign="middle" rowspan="1" colspan="1">35</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">20</td><td align="left" valign="middle" rowspan="1" colspan="1">Coal</td><td align="left" valign="middle" rowspan="1" colspan="1">11</td><td align="left" valign="middle" rowspan="1" colspan="1">2</td><td align="left" valign="middle" rowspan="1" colspan="1">6</td><td align="left" valign="middle" rowspan="1" colspan="1">2</td><td align="left" valign="middle" rowspan="1" colspan="1">1.96</td><td align="left" valign="middle" rowspan="1" colspan="1">WY, PA, KY, WV</td><td align="left" valign="middle" rowspan="1" colspan="1">35</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">113</td><td align="left" valign="middle" rowspan="1" colspan="1">Black shale with coal streaks</td><td align="left" valign="middle" rowspan="1" colspan="1">34</td><td align="left" valign="middle" rowspan="1" colspan="1">7</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">2</td><td align="left" valign="middle" rowspan="1" colspan="1">6.30</td><td align="left" valign="middle" rowspan="1" colspan="1">OH, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">35</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">114</td><td align="left" valign="middle" rowspan="1" colspan="1">Black shale</td><td align="left" valign="middle" rowspan="1" colspan="1">44</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">10</td><td align="left" valign="middle" rowspan="1" colspan="1">6</td><td align="left" valign="middle" rowspan="1" colspan="1">4.40</td><td align="left" valign="middle" rowspan="1" colspan="1">IL, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">39</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">119</td><td align="left" valign="middle" rowspan="1" colspan="1">Black shale with fossil shells</td><td align="left" valign="middle" rowspan="1" colspan="1">18</td><td align="left" valign="middle" rowspan="1" colspan="1">6</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">4</td><td align="left" valign="middle" rowspan="1" colspan="1">2.05</td><td align="left" valign="middle" rowspan="1" colspan="1">KY</td><td align="left" valign="middle" rowspan="1" colspan="1">39</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">122</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray layered shale</td><td align="left" valign="middle" rowspan="1" colspan="1">53</td><td align="left" valign="middle" rowspan="1" colspan="1">19</td><td align="left" valign="middle" rowspan="1" colspan="1">25</td><td align="left" valign="middle" rowspan="1" colspan="1">31</td><td align="left" valign="middle" rowspan="1" colspan="1">2.12</td><td align="left" valign="middle" rowspan="1" colspan="1">WV, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">45</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">123</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray shale with coal streaks</td><td align="left" valign="middle" rowspan="1" colspan="1">36</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">4</td><td align="left" valign="middle" rowspan="1" colspan="1">4.00</td><td align="left" valign="middle" rowspan="1" colspan="1">PA, WV, OH</td><td align="left" valign="middle" rowspan="1" colspan="1">33</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">124</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray shale</td><td align="left" valign="middle" rowspan="1" colspan="1">36</td><td align="left" valign="middle" rowspan="1" colspan="1">28</td><td align="left" valign="middle" rowspan="1" colspan="1">8</td><td align="left" valign="middle" rowspan="1" colspan="1">4</td><td align="left" valign="middle" rowspan="1" colspan="1">4.50</td><td align="left" valign="middle" rowspan="1" colspan="1">PA, WY, KY</td><td align="left" valign="middle" rowspan="1" colspan="1">36</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">127</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray fireclay</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">6</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">PA, OH, WV</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">137</td><td align="left" valign="middle" rowspan="1" colspan="1">Light gray green fireclay</td><td align="left" valign="middle" rowspan="1" colspan="1">33</td><td align="left" valign="middle" rowspan="1" colspan="1">45</td><td align="left" valign="middle" rowspan="1" colspan="1">6</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">5.50</td><td align="left" valign="middle" rowspan="1" colspan="1">KY</td><td align="left" valign="middle" rowspan="1" colspan="1">28</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">147</td><td align="left" valign="middle" rowspan="1" colspan="1">Green claystone</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">OH, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">237</td><td align="left" valign="middle" rowspan="1" colspan="1">Light gray green fireclay with limestone Nodules</td><td align="left" valign="middle" rowspan="1" colspan="1">64</td><td align="left" valign="middle" rowspan="1" colspan="1">24</td><td align="left" valign="middle" rowspan="1" colspan="1">24</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">2.67</td><td align="left" valign="middle" rowspan="1" colspan="1">PA</td><td align="left" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">322</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray shale and Interbedded sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">78</td><td align="left" valign="middle" rowspan="1" colspan="1">27</td><td align="left" valign="middle" rowspan="1" colspan="1">17</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">4.59</td><td align="left" valign="middle" rowspan="1" colspan="1">WV, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">48</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">323</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray shale with sandstone streaks</td><td align="left" valign="middle" rowspan="1" colspan="1">48</td><td align="left" valign="middle" rowspan="1" colspan="1">24</td><td align="left" valign="middle" rowspan="1" colspan="1">11</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">4.36</td><td align="left" valign="middle" rowspan="1" colspan="1">PA, KY</td><td align="left" valign="middle" rowspan="1" colspan="1">40</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">324</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray massive sandy shale</td><td align="left" valign="middle" rowspan="1" colspan="1">55</td><td align="left" valign="middle" rowspan="1" colspan="1">15</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">7</td><td align="left" valign="middle" rowspan="1" colspan="1">5.91</td><td align="left" valign="middle" rowspan="1" colspan="1">WV, PA, IL, KY</td><td align="left" valign="middle" rowspan="1" colspan="1">47</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">325</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray massive churned sandy shale</td><td align="left" valign="middle" rowspan="1" colspan="1">42</td><td align="left" valign="middle" rowspan="1" colspan="1">11</td><td align="left" valign="middle" rowspan="1" colspan="1">13</td><td align="left" valign="middle" rowspan="1" colspan="1">11</td><td align="left" valign="middle" rowspan="1" colspan="1">3.23</td><td align="left" valign="middle" rowspan="1" colspan="1">WV, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">48</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">327</td><td align="left" valign="middle" rowspan="1" colspan="1">Dark gray sandy fireclay</td><td align="left" valign="middle" rowspan="1" colspan="1">9</td><td align="left" valign="middle" rowspan="1" colspan="1">1</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">KY</td><td align="left" valign="middle" rowspan="1" colspan="1">29</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">332</td><td align="left" valign="middle" rowspan="1" colspan="1">Light gray green shale and Interbedded sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">32</td><td align="left" valign="middle" rowspan="1" colspan="1">10</td><td align="left" valign="middle" rowspan="1" colspan="1">10</td><td align="left" valign="middle" rowspan="1" colspan="1">6</td><td align="left" valign="middle" rowspan="1" colspan="1">3.20</td><td align="left" valign="middle" rowspan="1" colspan="1">IL, WY, KY</td><td align="left" valign="middle" rowspan="1" colspan="1">44</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">337</td><td align="left" valign="middle" rowspan="1" colspan="1">Light gray green sandy fire clay</td><td align="left" valign="middle" rowspan="1" colspan="1">41</td><td align="left" valign="middle" rowspan="1" colspan="1">8</td><td align="left" valign="middle" rowspan="1" colspan="1">39</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">1.05</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">357</td><td align="left" valign="middle" rowspan="1" colspan="1">Red and green sandy claystone</td><td align="left" valign="middle" rowspan="1" colspan="1">64</td><td align="left" valign="middle" rowspan="1" colspan="1">43</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">437</td><td align="left" valign="middle" rowspan="1" colspan="1">Red and green sandy fireclay with limestone</td><td align="left" valign="middle" rowspan="1" colspan="1">12</td><td align="left" valign="middle" rowspan="1" colspan="1">4</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">2</td><td align="left" valign="middle" rowspan="1" colspan="1">2.45</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">541</td><td align="left" valign="middle" rowspan="1" colspan="1">Gray crossbedded sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">61</td><td align="left" valign="middle" rowspan="1" colspan="1">5</td><td align="left" valign="middle" rowspan="1" colspan="1">24</td><td align="left" valign="middle" rowspan="1" colspan="1">13</td><td align="left" valign="middle" rowspan="1" colspan="1">2.49</td><td align="left" valign="middle" rowspan="1" colspan="1">PA, KY, WY</td><td align="left" valign="middle" rowspan="1" colspan="1">63</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">543</td><td align="left" valign="middle" rowspan="1" colspan="1">Gray sandstone with Shale Streaks ripple</td><td align="left" valign="middle" rowspan="1" colspan="1">80</td><td align="left" valign="middle" rowspan="1" colspan="1">48</td><td align="left" valign="middle" rowspan="1" colspan="1">28</td><td align="left" valign="middle" rowspan="1" colspan="1">14</td><td align="left" valign="middle" rowspan="1" colspan="1">2.86</td><td align="left" valign="middle" rowspan="1" colspan="1">OH, PA, WY, KY, WV</td><td align="left" valign="middle" rowspan="1" colspan="1">63</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">544</td><td align="left" valign="middle" rowspan="1" colspan="1">Gray massive sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">75</td><td align="left" valign="middle" rowspan="1" colspan="1">27</td><td align="left" valign="middle" rowspan="1" colspan="1">94</td><td align="left" valign="middle" rowspan="1" colspan="1">40</td><td align="left" valign="middle" rowspan="1" colspan="1">0.80</td><td align="left" valign="middle" rowspan="1" colspan="1">WV, KY, PA</td><td align="left" valign="middle" rowspan="1" colspan="1">77</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">749</td><td align="left" valign="middle" rowspan="1" colspan="1">Gray sandstone with coal spars</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">WV, OH</td><td align="left" valign="middle" rowspan="1" colspan="1">43</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">764</td><td align="left" valign="middle" rowspan="1" colspan="1">Hard quartz pebble conglomerate</td><td align="left" valign="middle" rowspan="1" colspan="1">98</td><td align="left" valign="middle" rowspan="1" colspan="1">23</td><td align="left" valign="middle" rowspan="1" colspan="1">67</td><td align="left" valign="middle" rowspan="1" colspan="1">35</td><td align="left" valign="middle" rowspan="1" colspan="1">1.46</td><td align="left" valign="middle" rowspan="1" colspan="1">PA</td><td align="left" valign="middle" rowspan="1" colspan="1">46</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">772</td><td align="left" valign="middle" rowspan="1" colspan="1">Shale breccia</td><td align="left" valign="middle" rowspan="1" colspan="1">22</td><td align="left" valign="middle" rowspan="1" colspan="1">2</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">782</td><td align="left" valign="middle" rowspan="1" colspan="1">Shale pebble shaley limestone breccia</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1">0</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1">KY</td><td align="left" valign="middle" rowspan="1" colspan="1">78</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">802</td><td align="left" valign="middle" rowspan="1" colspan="1">Layered fine grained shaley limestone</td><td align="left" valign="middle" rowspan="1" colspan="1">79</td><td align="left" valign="middle" rowspan="1" colspan="1">14</td><td align="left" valign="middle" rowspan="1" colspan="1">15</td><td align="left" valign="middle" rowspan="1" colspan="1">4</td><td align="left" valign="middle" rowspan="1" colspan="1">5.27</td><td align="left" valign="middle" rowspan="1" colspan="1">OH</td><td align="left" valign="middle" rowspan="1" colspan="1">63</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">804</td><td align="left" valign="middle" rowspan="1" colspan="1">Massive fine grained shaley limestone</td><td align="left" valign="middle" rowspan="1" colspan="1">61</td><td align="left" valign="middle" rowspan="1" colspan="1">32</td><td align="left" valign="middle" rowspan="1" colspan="1">41</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/><td align="left" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">894</td><td align="left" valign="middle" rowspan="1" colspan="1">Massive fine grained shaley limestone</td><td align="left" valign="middle" rowspan="1" colspan="1">30</td><td align="left" valign="middle" rowspan="1" colspan="1">16</td><td align="left" valign="middle" rowspan="1" colspan="1">14</td><td align="left" valign="middle" rowspan="1" colspan="1">3</td><td align="left" valign="middle" rowspan="1" colspan="1">2.14</td><td align="left" valign="middle" rowspan="1" colspan="1">KY</td><td align="left" valign="middle" rowspan="1" colspan="1">35</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">904</td><td align="left" valign="middle" rowspan="1" colspan="1">Massive fine grained sandstone</td><td align="left" valign="middle" rowspan="1" colspan="1">125</td><td align="left" valign="middle" rowspan="1" colspan="1">38</td><td align="left" valign="middle" rowspan="1" colspan="1">126</td><td align="left" valign="middle" rowspan="1" colspan="1">23</td><td align="left" valign="middle" rowspan="1" colspan="1">0.99</td><td align="left" valign="middle" rowspan="1" colspan="1">OH</td><td align="left" valign="middle" rowspan="1" colspan="1">100</td></tr></tbody></table></table-wrap></floats-group></article>