i
Evaluation of fiber optic methane sensor using a smoke chamber
-
Nov 2018
Source: Int J Min Sci Technol. 28(6):969-974
Details:
-
Alternative Title:Int J Min Sci Technol
-
Personal Author:
-
Description:This report presents the results of experiments to evaluate a prototype fiber optic methane monitor exposed to smoke using a smoke chamber to simulate atmospheric conditions in an underground coal mine after a fire or explosion. The experiments were conducted using test fires of different combustible sources commonly found in mines -douglas-fir wood, SBR belt, and Pittsburgh seam coal. The experiments were designed to assess the response of the fiber optic methane sensor to different contaminants, different contaminant levels and different contaminant durations produced from the test fires. Since the prototype methane monitor detects methane by measuring absorption at a specific wavelength, optical power at the absorption wavelength (1650 nm) was measured as a function of smoke concentration and duration. The other sensor response parameter-methane response times-were measured between smoke tests to assess the impact of soot accumulation on the sensor. Results indicate that the sensor screen effectively prevented smoke from obscuring the optical beam within the sensor head, with minimal impact on the system optical power budget. Methane response times increased with smoke exposure duration, attributed to soot loading on the protective screen.
-
Subjects:
-
Pubmed ID:30519497
-
Pubmed Central ID:PMC6275101
-
Document Type:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type:
Supporting Files
-
jpeg gif jpeg gif jpeg gif jpeg gif jpeg gif xml jpeg gif jpeg gif jpeg gif jpeg gif jpeg gif jpeg gif
More +