Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Field-use early-strength shotcrete test system

Filetype[PDF-751.86 KB]


  • English

  • Details:

    • Description:
      "Objective: To develop a practical method of measuring shotcrete early strength ansite in the first six hours after application using a partial beam test standard, ASTM C 1 16-90. Determining the early-strength development of as-sprayed shotcrete can improve mine safety by identifying appropriate reentry times and providing a convenient means of quality control during application. A more thorough understanding of shotcrete early strength will lead to improvements in ground support practices, thereby preventing ground falls and reducing mine roof-fall accidents. Background: When shotcrete is used as part of a multi component ground support system, it is important to know when the material has developed enough strength to be self-supporting and allow for reentry and emplacement of the remaining support elements that require drilling of the shotcrete layer without degradation. Typical reported values for this threshold strength for North American mines range from 1 to 1.6 MPa (145 to 233 psi) [O'Toole and Pope 2006], with a compressive strength equivalent to 1 MPa (145 psi) being the norm [Rispin et al. 2003; O'Toole and Pope 2006]. Typical ground control support includes a shotcrete flash coat 19- to 25-mm (3 /4- to 1-in) thick, followed by screen, plates, bolts, and a second layer of shotcrete bringing the combined thickness to 75 to 100 mm (3 to 4 in). In areas requiring rehabilitation, the second layer of shotcrete is plated and bolted as well. While testing cored samples after 24 hours is standard, this is not practical for the one- to six-hour period following application when shotcrete unconfined compressive strengths are less than 10 MPa (1 ,450 psi). Indirect methods are typically used to determine shotcrete strength during the early stages of curing because the partially cured or green material is difficult to sample and test. While problems with inconsistent test results have been reported with the penetrometer-type devices, beam molds have been used successfully for creating shotcrete test specimens in the United States and Canada. Operating the Partial Beam Test System: The test unit is a self-contained, servo-controlled, stiff-frame press. Partial beam test samples are obtained by spraying shotcrete into 102- x 102- x 152-mm (4- x 4- x 6-in) mold boxes. After the samples have been sprayed, tests are conducted at one-hour intervals over the next six hours (one- through six-hour tests). The shotcrete samples are carefully demolded by disassembling the mold fixtures and removing the enclosed sample. Next, a shotcrete sample is placed in a specialized testing fixture and centered under the loading head of the test machine. When the test sequence is initiated, a programmable-logic-controller- (PLC) driven press applies a fixed-rate load to the sample. The load profile is shown on a graphical output display, and the measured test parameters (time, displacement, and load) are stored on a thumb drive. Once the operator observes a well-defined peak in the load profile curve, the test is completed and the test machine's loading platen can be returned to its initial starting position. Peak load is typically reflected by the development of large vertically oriented cracks along the platen-to sample contact edges, which are indicative of the failure plane. There is a marked difference in early-strength gain between sprayed and cast shotcrete. The cast shotcrete samples have a similar strength gain profile to that of cast concrete samples." - NIOSHTIC-2

      NIOSH No 20039245

      Citation on Web page: Clark-CC, Seymour-JB, Martin-LA. Pittsburgh, PA: U. S. Department of Health and Human Services, Public Health Service, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication No. 2011-186, TN 541, 2011 Jun; :1-2.

    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov