i
Discordance between self-reported contraceptive use and detection of exogenous hormones among Malawian women enrolling in a randomized clinical trial☆
-
December 13 2017
Source: Contraception. 97(4):354-356 -
Alternative Title:Contraception
-
Personal Author:
-
Description:Objective
The objective was to assess the extent of concordance between self-reported contraceptive use and the presence of contraceptive progestins in serum.
Study design
We evaluated self-reported contraceptive use by using radioimmunoassay to examine baseline serum levels of medroxyprogesterone acetate (MPA) and levonorgestrel (LNG) among 97 Malawian women enrolling in a contraceptive trial.
Results
Twelve percent (12/97) of study participants who reported no hormonal contraceptive use in the previous 6 months had either MPA or LNG detected in their serum.
Conclusions
The observed discordance between self-report and detection of exogenous hormones in serum indicates that caution is warranted when drawing conclusions based on self-reported contraceptive use.
-
Subjects:
-
Source:
-
Pubmed ID:29246819
-
Pubmed Central ID:PMC5840008
-
Document Type:
-
Funding:
-
Collection(s):
-
Main Document Checksum:
-
Download URL:
-
File Type: