<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">9804161</journal-id><journal-id journal-id-type="pubmed-jr-id">26744</journal-id><journal-id journal-id-type="nlm-ta">Sleep Breath</journal-id><journal-id journal-id-type="iso-abbrev">Sleep Breath</journal-id><journal-title-group><journal-title>Sleep &#x00026; breathing = Schlaf &#x00026; Atmung</journal-title></journal-title-group><issn pub-type="ppub">1520-9512</issn><issn pub-type="epub">1522-1709</issn></journal-meta><article-meta><article-id pub-id-type="pmid">28823109</article-id><article-id pub-id-type="pmc">5818320</article-id><article-id pub-id-type="doi">10.1007/s11325-017-1547-9</article-id><article-id pub-id-type="manuscript">NIHMS900967</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Comparison of two home sleep testing devices with different strategies for diagnosis of OSA</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Gumb</surname><given-names>Tyler</given-names></name><degrees>BA</degrees><xref ref-type="aff" rid="A1">1</xref></contrib><contrib contrib-type="author"><name><surname>Twumasi</surname><given-names>Akosua</given-names></name><degrees>MA</degrees><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Alimokhtari</surname><given-names>Shahnaz</given-names></name><degrees>MA</degrees><xref ref-type="aff" rid="A3">3</xref></contrib><contrib contrib-type="author"><name><surname>Perez</surname><given-names>Alan</given-names></name><degrees>BS</degrees><xref ref-type="aff" rid="A3">3</xref></contrib><contrib contrib-type="author"><name><surname>Black</surname><given-names>Kathleen</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="A3">3</xref></contrib><contrib contrib-type="author"><name><surname>Rapoport</surname><given-names>David M.</given-names></name><degrees>MD</degrees><xref ref-type="aff" rid="A1">1</xref><xref ref-type="aff" rid="A2">2</xref></contrib><contrib contrib-type="author"><name><surname>Sunderram</surname><given-names>Jag</given-names></name><degrees>MD</degrees><xref ref-type="aff" rid="A4">4</xref></contrib><contrib contrib-type="author"><name><surname>Ayappa</surname><given-names>Indu</given-names></name><degrees>PhD</degrees><xref ref-type="aff" rid="A1">1</xref><xref ref-type="aff" rid="A2">2</xref></contrib></contrib-group><aff id="A1">
<label>1</label>Division of Pulmonary, Critical Care, and Sleep Medicine, Department of Medicine, New York University School of Medicine, New York, NY, USA</aff><aff id="A2">
<label>2</label>Division of Pulmonary, Critical Care and Sleep Medicine, Icahn School of Medicine at Mount Sinai, New York, NY, USA</aff><aff id="A3">
<label>3</label>Environmental and Occupational Health Sciences Institute, Rutgers Robert Wood Johnson Medical School, Piscataway, NJ, USA</aff><aff id="A4">
<label>4</label>Department of Medicine, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, 08903 USA</aff><author-notes><corresp id="FN1">Corresponding Author Information: Indu Ayappa, One Gustave L. Levy Place, Box 1232, New York, NY 10029, <email>indu.ayappa@mssm.edu</email>, Tel: 212-241-1967, Fax: 212-876-5519</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>21</day><month>8</month><year>2017</year></pub-date><pub-date pub-type="epub"><day>19</day><month>8</month><year>2017</year></pub-date><pub-date pub-type="ppub"><month>3</month><year>2018</year></pub-date><pub-date pub-type="pmc-release"><day>01</day><month>3</month><year>2019</year></pub-date><volume>22</volume><issue>1</issue><fpage>139</fpage><lpage>147</lpage><!--elocation-id from pubmed: 10.1007/s11325-017-1547-9--><abstract><sec id="S1"><title>Purpose</title><p id="P1">Home sleep testing devices are being widely used in diagnosis/screening for obstructive sleep apnea (OSA). We examined differences in OSA metrics obtained from two devices with divergent home monitoring strategies; the Apnea Risk Evaluation System (ARES&#x02122;, multiple signals plus forehead reflectance oximetry) and the Nonin WristOx<sub>2</sub>&#x02122; (single channel finger transmission pulse oximeter), compared to differences from night-night variability of OSA.</p></sec><sec id="S2"><title>Methods</title><p id="P2">152 male / 26 female subjects (BMI=30.3&#x000b1;5.6 kg/m2, age=52.5&#x000b1;8.9 yrs) were recruited without regard to OSA symptoms, and simultaneously wore both ARES&#x02122; and Nonin WristOx<sub>2</sub>&#x02122; for 2 nights (n=351 nights). Automated analysis of the WristOx<sub>2</sub> yielded ODI<sub>Ox2</sub> (Oxygen Desaturation Index, #&#x02265;4% O2 dips/hr) and automated analysis with manual editing of ARES&#x02122; yielded AHI4<sub>ARES</sub> (apneas+hypopneas with &#x02265;4% O2 dips/hr) and RDI<sub>ARES</sub> (apneas+ hypopneas with &#x02265;4% O2 dips/hr or arousal surrogates). Baseline awake oxygen saturation, percent time &#x0003c;90% O2 saturation (% time &#x0003c;90% O2Sat) and O2 signal loss were compared between the two methods.</p></sec><sec id="S3"><title>Results</title><p id="P3">Correlation between AHI4<sub>ARES</sub> and ODI<sub>Ox2</sub> was high (ICC=0.9, 95% CI=0.87&#x02013;0.92, p&#x0003c;0.001, bias&#x000b1;SD=0.7&#x000b1;6.1 events/hr). Agreement values for OSA diagnosis (77&#x02013;85%) between devices was similar to that seen from night-to-night variability of OSA using a single device. Awake baseline O2 saturation was significantly higher in the ARES&#x02122; (96.2&#x000b1;1.6%) than WristOx<sub>2</sub>&#x02122; (92.2&#x000b1;2.1%, p&#x0003c;0.01). There was a significantly lower %time&#x0003c;90% O2Sat reported by the ARES&#x02122; compared to WristOx<sub>2</sub> (median (IQR) 0.5(0.0, 2.6) vs 2.1(0.3, 9.7), p&#x0003c;0.001) and the correlation was low (ICC=0.2).</p></sec><sec id="S4"><title>Conclusions</title><p id="P4">OSA severity metrics predominantly dependent on change in oxygen saturation and metrics used in diagnosis of OSA (AHI4 and ODI) correlated well across devices tested. However differences in cumulative oxygen desaturation measures (i.e.% time&#x0003c;90% O2Sat) between the devices suggest caution is needed when interpreting this metric particularly in populations likely to have significant hypoxia.</p></sec></abstract><kwd-group><kwd>Sleep Disordered Breathing</kwd><kwd>Oximetry</kwd><kwd>Portable Monitoring</kwd><kwd>Obstructive Sleep Apnea</kwd><kwd>Limited Channel Monitoring</kwd></kwd-group></article-meta></front><body><sec sec-type="intro" id="S5"><title>Introduction</title><p id="P5">Diagnosis of obstructive sleep apnea (OSA) is increasingly being made with limited channel monitoring (level III and IV devices) in both clinical and epidemiological settings. However, the devices being used vary from single channel oximeters to devices that monitor multiple signals such as airflow, breathing efforts, oxygen saturation and surrogates for arousal. When disease is moderate to severe, both Level IV and Level III devices have been shown to have value in screening as well as in establishing the diagnosis of OSA [<xref rid="R1" ref-type="bibr">1</xref>, <xref rid="R2" ref-type="bibr">2</xref>]. The American Academy of Sleep Medicine (AASM) has suggested only level III devices should be used to obtain OSA severity indices comparable to that obtained with full polysomnography (PSG) [<xref rid="R3" ref-type="bibr">3</xref>&#x02013;<xref rid="R7" ref-type="bibr">7</xref>]. However as noted by the recent AASM guidelines document for diagnostic testing for OSA [<xref rid="R8" ref-type="bibr">8</xref>], there are limited data in the literature assessing the impact of the number of parameters or technologies being used, particularly in different clinical settings. We were interested in assessing the impact of using maximally different diagnostic devices on derivation of indices of OSA severity and the agreement between devices for OSA diagnosis.</p><p id="P6">One potentially important difference between devices is the technology used for oximetry as well as the measurement site which may lead to true physiologic differences in oxygen saturation. Pulse oximetry can be measured using either transmission or reflectance techniques. Transmission oximetry detects light after it passes through relatively translucent placement sites, such as the fingertips or earlobes, whereas reflectance oximetry detects reflected light from tissue that is opaque (eg. forehead sensors). There are known differences in the measurement of oxygen saturation (O2Sat) using these two methods [<xref rid="R9" ref-type="bibr">9</xref>], but, e<italic>ven by a single technique,</italic> we and others have shown a significant effect of pulse oximeter brand and sample averaging duration on OSA diagnosis [<xref rid="R10" ref-type="bibr">10</xref>&#x02013;<xref rid="R12" ref-type="bibr">12</xref>]. No study has specifically addressed the impact on OSA diagnosis of using reflectance vs transmission oximetry technique with currently used devices.</p><p id="P7">Additionally, identifying sleep related respiratory events (apneas /hypopneas) using only their consequences (eg O2 desaturation) may differ from detecting events as by reduction in airflow and assessing their significance from the oximetry signal. Finally, some devices also use surrogates for EEG arousal and use these to maximize similarity to polysomnography detection of hypopnea. Given all these differences the purpose of the present study was to compare the effect on diagnosis of OSA using two devices that are maximally different in their approach to measure OSA severity. The present study compares data from a widely used stand-alone level IV device the Nonin WristOx<sub>2</sub>&#x02122; (Model 3150, Plymouth, MN) and a level III device , the Apnea Risk Evaluation System (ARES&#x02122;, Watermark Medical, Boca Raton, FL) that uses reflectance oximetry combined with other signals (<xref rid="F1" ref-type="fig">Fig 1</xref>). We have previously shown that the ARES&#x02122; has good agreement and adequate sensitivity and specificity with in-laboratory polysomnography for diagnosis of OSA [<xref rid="R4" ref-type="bibr">4</xref>]. For the present study, we compared these devices in a non-sleep clinic population which, in contrast to sleep clinic populations, does not have the high pre-test probability of OSA. Specifically, we compared (i) the amount of data loss with each device and type of oximetry; (ii) baseline awake O2 saturation and %time below 90% O2 saturation and (iii) agreement between the values of OSA severity, and agreement for diagnosis of OSA from these devices, compared to the physiologic night-to-night variability of these metrics. We hypothesized that there would be significant differences in sleep disordered breathing (SDB) indices and diagnostic agreement for OSA when using finger pulse oximetry alone versus a device that measures multiple parameters including airflow, forehead oxygen saturation and surrogates for the EEG arousal.</p></sec><sec sec-type="methods" id="S6"><title>Methods</title><p id="P8">Data from the first 178 subjects who enrolled in an ongoing study in the World Trade Center Responder population (Clinical trials # NCT01753999) were analyzed. The parent study collects exclusively ambulatory overnight home studies to evaluate the relationship between new onset OSA following the WTC disaster on 9/11/2001 and nasal pathology. Subjects were recruited without regard to OSA symptoms, but were not eligible if prior to 9/11/2001 they had documented evidence of OSA or significant snoring or if they were currently on treatment for OSA. For the present substudy, subjects were instructed to wear the WristOx<sub>2</sub>&#x02122;, and ARES&#x02122; simultaneously for 2 consecutive nights. Both devices were initialized on the same computer to synchronize the internal clocks. Devices were given to the patients during an in person visit. A research coordinator provided verbal instructions that took &#x0003c;5 minutes and a 1 page pamphlet with written instructions was also provided to the subjects. No additional interaction with the patient was required. Both devices are easy to self-apply and we have used the ARES&#x02122; successfully with just the written instructions in previous studies [<xref rid="R4" ref-type="bibr">4</xref>]. The ARES&#x02122; measures oximetry on the forehead, and the subjects wore the WristOx<sub>2</sub>&#x02122; on whichever hand they were more comfortable. Data were excluded from analysis if both devices were not used on the same night or if the duration of recording on either device was less than 2 hours (tabulated as data loss).</p><p id="P9">WristOx<sub>2</sub>&#x02122;: Oximetry by transmission was sampled at 1 Hz with an averaging time of 4 beats. Automated analysis of the WristOx<sub>2</sub> data, using Nonin nVision data management software version 6.3, provided an index of OSA severity, the oxygen desaturation index (ODI<sub>ox2</sub>) and % time below 90% O2 saturation (%time&#x0003c;90%O2Sat) for each night. ODI<sub>Ox2</sub> was defined as the number of drops in saturation by at least 4% lasting a minimum of 10 seconds per hour of valid recording time as defined by the Nonin software. We inferred the awake baseline O2 saturation from a period at the beginning of the study within the first 10 minutes from the start of the recording. Poor signal quality was identified and excluded in the oximetry data using the automated algorithm on the WristOx<sub>2</sub>. The signal was manually inspected to ensure validity of the algorithm and no further editing was required.</p><p id="P10">ARES&#x02122;: Oximetry by reflectance was sampled at 100 Hz with an averaging time of 3&#x02013;5 beats depending on signal quality, and displayed at 1 Hz. Automated analysis of SDB events was followed by manual inspection and editing of events by investigator as per device use instructions. ODI is not provided by the ARES&#x02122; automated algorithm, so a direct comparison of transmittance and reflectance saturation derived SDB was not possible in our study. The closest measure to ODI provided by the ARES&#x02122; is the AHI4 which counts apneas and those hypopneas with a &#x02265;4% desaturation. The Apnea Hypopnea Index 4% from ARES&#x02122; (AHI4<sub>ARES</sub>) is calculated as the sum of apneas and hypopneas 4% divided by total sleep time (TST); apneas were defined as a reduction in flow amplitude of &#x0003e;90% of baseline, hypopneas 4% were defined as a reduction in flow amplitude &#x0003e;30% followed by &#x02265;4% oxygen desaturation, or a visible reduction in flow amplitude along with a change in shape suggesting inspiratory flow limitation (IFL) followed by &#x02265;4% oxygen desaturation. The ARES&#x02122; provides an estimate of total sleep time obtained from a combination of actigraphy and automated analysis of single channel forehead EEG recording [<xref rid="R13" ref-type="bibr">13</xref>].</p><p id="P11">The ARES&#x02122; also provides a Respiratory Disturbance Index (RDI<sub>ARES</sub>): sum of apneas, hypopneas 4% and hypopneaArousal divided by TST; hypopneaArousal was defined by a visible reduction (usually &#x0003e;30%) in flow amplitude along with a change in shape suggesting inspiratory flow limitation and followed by arousal surrogates that included an abrupt change in head position or an increase in flow amplitude to &#x0003e;2 times the amplitude during the event along with a normalization of shape.</p><p id="P12">For ARES&#x02122;oximetry data, automated algorithms were first applied to exclude areas with poor quality oximetry. This was followed by additional manual editing to exclude areas with sustained drops in O2 saturation following body position changes but not associated with SDB events.</p><p id="P13">For normally distributed variables data are presented as mean&#x000b1;SD and groups compared using paired t-test. Data are presented as median (IQR) and Wilcoxon Rank Sum tests were used to compare groups when data was not normally distributed. Concordance of SDB indices was assessed by performing Intraclass Correlations (ICC) between ODI<sub>Ox2</sub> and AHI4<sub>ARES</sub>, and both devices&#x02019; baseline O2 saturation level and %time&#x0003c;90%O2Sat [<xref rid="R14" ref-type="bibr">14</xref>]. Bland Altman plots were used to measure bias and differences between these measures and Pearson correlation coefficients ( r) were used to assess relationships between other related variables [<xref rid="R15" ref-type="bibr">15</xref>]. Agreement, sensitivity and specificity for diagnosis of OSA were examined using standard cutoffs for OSA (i.e.&#x02265;5/hr,&#x0003e;15/hr). Analyses were performed between devices using all nights in all subjects and between pairs of data for comparisons across nights using the same device.</p></sec><sec sec-type="results" id="S7"><title>Results</title><p id="P14">351 nights of data were analyzed from 178 subjects (85.3% Male, 14.6% Female, BMI=30.3&#x000b1;5.6 kg/m2, age=52.5&#x000b1;8.9 years, Epworth Sleepiness Scale (ESS)=8.5&#x000b1;5, 37% with ESS&#x0003e;10). The reported prevalence of congestive heart failure= 2.3%; hypertension =25%; stroke=0.6%; MI=2%; diabetes=10%; gastro-esophageal reflux disease=40%, chronic-rhinosinusitis=42% and mental-health conditions (depression, post traumatic stress disorder, panic disorder)=15%. 8% were current smokers. The prevalence of OSA in this dataset was 28% using a cutoff AHI4&#x02265;15/hr (data from multiple nights collected for each subject combined) and 62% for AHI4&#x02265;5/hr. The prevalence values were 10% and 22% when the coexistence of excessive daytime somnolence (ESS&#x0003e;10) was included in the definition of OSA.</p><p id="P15">Majority of the subjects (73%) used both devices simultaneously for 2 nights, 4% for three nights and the remaining 23% of subjects used both devices for only one night. 11.7% (n=41/351 nights) of data were excluded for having &#x0003c;2hrs of data on either device (10.8% Wrist Ox<sub>2</sub>; 2.3% ARES&#x02122;) leaving 310 nights with <bold>simultaneous</bold> ARES&#x02122; and Wrist Ox<sub>2</sub> data, and 130 studies with 2 nights of data with each of the devices.</p><sec id="S8"><title>Comparison between Devices</title><p id="P16">The average duration of data recorded was 5.8&#x000b1;1.5 hours/night on the ARES&#x02122; and 6.2&#x000b1;1.8 hours/night on the WristOx<sub>2</sub>&#x02122;. Over the 310 nights analyzed, there was a significantly greater percentage of time with poor quality O2 saturation on the ARES&#x02122; device compared to the WristOx<sub>2</sub>&#x02122; (median (IQR) 8.9% (3.6, 20.3) vs. 0.7% (0.2, 1.4), p&#x0003c;0.01; See <xref rid="T1" ref-type="table">Table 1</xref>). <xref rid="F2" ref-type="fig">Figure 2</xref> shows the histogram of % time with poor quality O2 saturation for each device. There was no correlation between the amount of data loss that occurred on the two devices (r=0.1, p=NS), suggesting this was a device-determined, and not patient-specific finding. In addition, when we identified the individual subjects with the most data loss (top 5%) for each device, there was no overlap between individuals who showed large data loss with the ARES&#x02122; or WristOX<sub>2</sub>&#x02122;.</p><p id="P17"><xref rid="T1" ref-type="table">Table 1</xref> shows significant differences in reported %time&#x0003c;90%O2Sat between the ARES&#x02122; and WristOx<sub>2</sub> devices. <xref rid="F3" ref-type="fig">Figure 3</xref> shows the poor correlation in this metric between the devices, and that the ARES&#x02122; reported less %time&#x0003c;90%O2Sat, especially when higher levels of percent time below 90% were measured by the WristOx<sub>2</sub>. Only 213 nights (60.7%) had &#x0003c;5% difference in the %time&#x0003c;90%O2Sat recorded by the two devices. Baseline awake O2Sat was significantly higher with the ARES&#x02122; than the WristOX<sub>2</sub>&#x02122; (<xref rid="T1" ref-type="table">Table 1</xref>). The correlation between the baseline awake O2Sat values from the two devices was poor and did not reach statistical significance (r=0.1, p=0.08).</p><p id="P18">BMI was correlated with the %time&#x0003c;90%O2Sat in both the ARES&#x02122; (r= 0.3, p&#x0003c;0.01) and the WristOx<sub>2</sub>&#x02122; (r=0.4, p&#x0003c;0.01). BMI also correlated with the difference in %time&#x0003c;90%O2Sat between the two devices (r=0.3, p&#x0003c;0.01).</p><p id="P19"><xref rid="T1" ref-type="table">Table 1</xref> shows the SDB indices obtained using the ARES (AHI4<sub>ARES</sub>, RDI<sub>ARES</sub>) and Wrist Ox2 (ODI<sub>Ox2</sub>). Correlation between AHI4<sub>ARES</sub> and ODI<sub>Ox2</sub> was high (ICC=0.9, bias&#x000b1;SD=0.7&#x000b1;6.1, See <xref rid="F4" ref-type="fig">Figure 4</xref>). A small bias was observed with AHI4<sub>ARES</sub> systematically slightly higher than ODI<sub>Ox2</sub> (but with wide limits of agreement). <xref rid="T2" ref-type="table">Table 2A</xref> shows the % agreement for diagnosing OSA, the associated kappa and sensitivity, specificity and false negative rates using cutoffs of &#x02265;5/hr &#x02265;15 events/hour with ARES&#x02122; as the gold standard. If sleepiness was required for the definition of OSA, the agreement rate was unchanged when a cutoff of &#x02265;5/hr was used and slightly improved at 93% when a cutoff of &#x02265;15/hr was used. If the more sensitive metric, RDI<sub>ARES</sub> (with a cutoff of &#x02265;15/hr), was used for diagnosis of OSA 20 (6.4%) additional diagnoses of OSA are identified compared to AHI4&#x02265;5/hr and 22 (7%) additional diagnoses are identified compared to ODI&#x02265;5/hr. <xref rid="T3" ref-type="table">Table 2B</xref> shows agreement for OSA diagnosis between N1 vs N2.</p><p id="P20">Comparison of differences in OSA metrics between <italic>devices</italic> versus between <italic>nights using the same device</italic> is shown in <xref rid="T4" ref-type="table">Table 3</xref>. The magnitude of the difference (bias) in the indices (AHI/ODI) between night 1 (N1) and night 2 (N2) was not statistically different and consistent with data in the literature with no significant first-night effect [<xref rid="R16" ref-type="bibr">16</xref>&#x02013;<xref rid="R19" ref-type="bibr">19</xref>]. This difference in AHI4/ODI seen when the same device is used on 2 separate nights was of similar magnitude as the (absolute) difference in the same index between the two different devices when used simultaneously. There were small differences in %time&#x0003c;90%O2Sat and baseline awake O2Sat between N1 and N2 consistent with the stated accuracy of the devices. The difference in the %time&#x0003c;90% and awake O2Sat between nights (using the same device) was of lower magnitude than differences <italic>between the 2 devices</italic> used simultaneously on the same night.</p></sec></sec><sec sec-type="discussion" id="S9"><title>Discussion</title><p id="P21">This is the first study to our knowledge that examines the differences in SDB metrics obtained from divergent home monitoring strategies, using different types of oximetry and contrasting a Level III forehead device and a Level IV finger device. As both the ARES&#x02122; and WristOx<sub>2</sub>&#x02122; devices are widely used our results have implications for comparing clinical and epidemiological datasets. In the simultaneously recorded home data of this large dataset of non-sleep clinic subjects, there were significant differences in the baseline awake O2Sat and %time&#x0003c;90%O2Sat obtained from the two devices. Despite this, the correlation between ODI<sub>Ox2</sub> and AHI4<sub>ARES</sub> was high. Agreement and rate of false negatives identified for diagnosis of OSA were similar to those seen due to night-to-night variability in SDB.</p><p id="P22">We and others have compared limited channel monitoring devices (level III and IV) and shown good sensitivity (80&#x02013;89%) and specificity (86&#x02013;94%) for diagnosis of OSA compared to full laboratory PSG [<xref rid="R1" ref-type="bibr">1</xref>, <xref rid="R2" ref-type="bibr">2</xref>, <xref rid="R20" ref-type="bibr">20</xref>&#x02013;<xref rid="R23" ref-type="bibr">23</xref>]. A recent study compared a level III device (ApneaLink Plus, which uses transmittance finger pulse oximetry) and a stand-alone finger pulse oximeter (Pulsox 300i) used at home against an in-lab NPSG in a sleep clinic population with suspected OSA [<xref rid="R24" ref-type="bibr">24</xref>]. This report showed good agreement between indices of OSA that required &#x02265;4% oxygen desaturation, calculated from either a single pulse oximetry or multi- channel PSG recording. We have also previously found that significant differences occur in AHI4 obtained when different brands of finger pulse oximeters were used in the same patient [<xref rid="R10" ref-type="bibr">10</xref>]: the biases found in AHI4 in that study ranged from 0.3&#x000b1;1.7/hr to 7.1&#x000b1;9.6/hr and were in the same order of magnitude for biases in AHI4/ODI (0.7&#x000b1;6.1) seen in the present study between finger transmission and forehead reflectance oximetry. These data suggest differences in measurement may be device dependent in addition to varying with the method of oximetry used [<xref rid="R10" ref-type="bibr">10</xref>].</p><p id="P23">In contrast to the results for the SDB index, we found significant and systematic device-dependent differences in the percent time&#x0003c;90%O2Sat. As neither device is the gold standard for oxygen saturation and we did not obtain a blood gas, it is impossible to know which of the two measures better reflected actual O2 saturation levels. We believe a significant contributor to the systematic difference in oximetry observed in our study is the oximeter type. However, differences in averaging or sampling rates may have contributed [<xref rid="R10" ref-type="bibr">10</xref>]. It is also likely that calibration of the oximetry signal will account for differences in percent time below 90%; in support of this, our data showed differences in the simultaneously measured baseline awake saturation across the two devices. In addition, physiologic O2 saturation may be different at the forehead and finger as temperature and blood flow have been shown to influence O2 saturation and may differ [<xref rid="R25" ref-type="bibr">25</xref>]. The Wrist Ox<sub>2</sub>&#x02122; O2 saturation measurement at the beginning of the night was lower than the ARES device, consistent with the overall greater percent time&#x0003c;90%O2Sat reported by the Wrist Ox<sub>2</sub>. In addition, the manual editing of the ARES data may have contributed by being more aggressive during periods of low O2 saturation/poor signal quality. This likely will result in removal of more periods of low O2 saturation (&#x0201c;poor signal&#x0201d;) with the ARES algorithm than with the fully automated Wrist Ox<sub>2</sub> algorithm. Irrespective of the cause, the significant observed differences in reported %time&#x0003c;90%O2Sat suggest care must be taken whenever comparing these data across studies using portable monitors with different oximeter types or algorithms.</p><p id="P24">Although data loss from oximetry was &#x0003c;10% for both devices, the ARES&#x02122; device had significantly greater data loss than the Wrist Ox<sub>2</sub>. This may be due to a lower signal to noise ratio in forehead reflectance oximetry compared to transmission. Review of oximetry tracings suggests that the forehead signal is particularly susceptible to data loss during movement (as during position changes) possibly due to positional changes in venous blood flow to the forehead. On the other hand, our data showed that in the WristOx<sub>2</sub> studies we had more nights with insufficient duration of data recorded for analysis (nights with &#x0003c;2 hours) than in the ARES&#x02122; studies. Possible reasons include the more precarious placement of the Wrist Ox<sub>2</sub> on the fingertip, allowing for the device to fall off the patient more easily than with the ARES&#x02122;, which is secured around the forehead by an elastic strap and a nasal cannula.</p><p id="P25">The impact of the ability to score any SDB events <italic>without</italic> 4% O2 desaturation (e.g. those with arousal surrogates) using the ARES&#x02122; is reflected in the additional 20 (6.4%) diagnoses that were made when using RDI data from this device. This suggests that mild OSA captured by the RDI may be missed by the oximeter alone. Based on our prior work, we used a cut-off of &#x02265;15/hr for OSA diagnosis when events with O2 desaturation <italic>and/or arousal</italic> were included in the index (i.e. RDI) as opposed to the AASM guideline cutoff&#x02265;5/hr for diagnosis of OSA when using an SDB index that includes hypopneas defined by O2 desaturation alone [<xref rid="R26" ref-type="bibr">26</xref>]. We and others have demonstrated the validity of this higher cutoff for OSA whenever using the more inclusive definition of RDI [<xref rid="R4" ref-type="bibr">4</xref>, <xref rid="R23" ref-type="bibr">23</xref>, <xref rid="R27" ref-type="bibr">27</xref>]. If one is interested in more than just the overall SDB and oximetry indices the ARES&#x02122; device provides additional information, such as sleep position and indirect confirmation of obstruction from snoring and from the shape of the airflow signal (inspiratory flow limitation), but this comes at a cost of additional time required for review and manual editing of data. A recent study by Chai-Coetzer et al showed excellent agreement of indices for diagnosis for moderate to severe OSA of both Level III and Level IV devices compared to PSG. However, this study also showed slightly worse functional outcomes when Level IV (oximetry alone) was used for OSA management, but similar outcomes between PSG and level III analysis [<xref rid="R2" ref-type="bibr">2</xref>]. The authors suggested that this was due to reduced physician confidence when using only a single channel, which is consistent with our previously published work [<xref rid="R28" ref-type="bibr">28</xref>].</p><p id="P26">Although our population composition was closer to an epidemiologic population (subjects were recruited without regard to symptoms of OSA and do not have significant co-morbid cardiovascular and metabolic conditions), the majority of our subjects were overweight, middle aged men. This likely contributed to the high prevalence of OSA. It remains to be tested whether our results can be generalized to a population with comorbid conditions showing significant hypoxemia.</p><p id="P27">Limitations of our study include the lack of a definitive reference measure of oximetry and not having comparison to in-laboratory PSG. Also, AHI4 by design includes apneas irrespective of any desaturation, and thus differs from the ODI, which only counts &#x02265;4% desaturations. It has been estimated at least 20% of apneas may not have accompanying desaturation [<xref rid="R29" ref-type="bibr">29</xref>]. This may explain why the AHI4<sub>ARES</sub> was slightly higher than the ODI<sub>Ox2</sub> (i.e., due to inclusion of apnea events without desaturation).</p></sec><sec sec-type="conclusions" id="S10"><title>Conclusion</title><p id="P28">In our study population the level IV device (Wrist<sub>Ox2</sub>) showed good agreement for diagnosis of OSA compared to the level III device (ARES&#x02122;) despite different approaches to signals monitored. The disagreement between the devices for the same index and between OSA diagnoses based on AHI4&#x02265;5/hr and RDI&#x02265;15/hr with a single device were comparable to night-night variability in our study and reported in previous publications. This suggests using oximetry alone with the ODI&#x02265;5/hr as a criterion to diagnose OSA may detect OSA with a clinically acceptable success in populations composed of middle aged overweight males with few comorbidities. Whether the number of patients missed by ODI vs AHI4 or RDI will increase above 10% in other populations, such as pediatrics or patients with minimally desaturating events, will need to be tested separately in future studies.</p></sec></body><back><ack id="S11"><p><bold>Funding:</bold> This study was funded by NIOSH/CDC U01OH010415 and NIH K24 grant HL109156.</p><p>DMR has received support for research from the industry in the past 24 months: grants from Fisher &#x00026; Paykel Healthcare, and speaking and consulting engagements for Fisher &#x00026; Paykel Healthcare. DMR holds multiple US and foreign patents covering techniques and analysis algorithms for the diagnosis of OSA and techniques for administering CPAP. Several of these have been licensed to Biologics, Fisher &#x00026; Paykel Healthcare, Advanced Brain Monitoring, and Sefam Medical.</p><p>JS has received support for speaker training from Merck Pharmaceuticals.</p><p>IA has received support for research from the industry in the past 24 months: grants from Fisher &#x00026; Paykel Healthcare. IA holds multiple US and foreign patents covering techniques and analysis algorithms for the diagnosis of OSA and techniques for administering CPAP. Several of these have been licensed to Fisher &#x00026; Paykel Healthcare and Advanced Brain Monitoring.</p></ack><fn-group><fn id="FN2"><p><bold>Work performed at:</bold> NYU Sleep Disorders Center and Rutgers Robert Wood Johnson Medical School</p></fn><fn id="FN3"><p><bold>Ethical approval:</bold> All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.</p></fn><fn id="FN4"><p><bold>Informed consent:</bold> Informed consent was obtained from all individual participants included in the study.</p></fn><fn fn-type="COI-statement" id="FN5"><p><bold>Conflicts of Interest:</bold></p><p>TG, AT, SA, AP, and KB have no conflicts of interest to disclose.</p></fn></fn-group><ref-list><ref id="R1"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hang</surname><given-names>LW</given-names></name><name><surname>Wang</surname><given-names>HL</given-names></name><name><surname>Chen</surname><given-names>JH</given-names></name><name><surname>Hsu</surname><given-names>JC</given-names></name><name><surname>Lin</surname><given-names>HH</given-names></name><name><surname>Chung</surname><given-names>WS</given-names></name><etal/></person-group><article-title>Validation of overnight oximetry to diagnose patients with moderate to severe obstructive sleep apnea</article-title><source>BMC Pulm Med</source><year>2015</year><volume>15</volume><fpage>24</fpage><pub-id pub-id-type="pmid">25880649</pub-id></element-citation></ref><ref id="R2"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chai-Coetzer</surname><given-names>CL</given-names></name><name><surname>Antic</surname><given-names>NA</given-names></name><name><surname>Hamilton</surname><given-names>GS</given-names></name><name><surname>McArdle</surname><given-names>N</given-names></name><name><surname>Wong</surname><given-names>K</given-names></name><name><surname>Yee</surname><given-names>BJ</given-names></name><etal/></person-group><article-title>Physician Decision Making and Clinical Outcomes With Laboratory Polysomnography or Limited-Channel Sleep Studies for Obstructive Sleep Apnea: A Randomized Trial</article-title><source>Ann Intern Med</source><year>2017</year><volume>166</volume><issue>5</issue><fpage>332</fpage><lpage>40</lpage><pub-id pub-id-type="pmid">28114683</pub-id></element-citation></ref><ref id="R3"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Collop</surname><given-names>NA</given-names></name><name><surname>Anderson</surname><given-names>WM</given-names></name><name><surname>Boehlecke</surname><given-names>B</given-names></name><name><surname>Claman</surname><given-names>D</given-names></name><name><surname>Goldberg</surname><given-names>R</given-names></name><name><surname>Gottlieb</surname><given-names>DJ</given-names></name><etal/></person-group><article-title>Clinical guidelines for the use of unattended portable monitors in the diagnosis of obstructive sleep apnea in adult patients. Portable Monitoring Task Force of the American Academy of Sleep Medicine</article-title><source>J Clin Sleep Med</source><year>2007</year><volume>3</volume><issue>7</issue><fpage>737</fpage><lpage>47</lpage><pub-id pub-id-type="pmid">18198809</pub-id></element-citation></ref><ref id="R4"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ayappa</surname><given-names>I</given-names></name><name><surname>Norman</surname><given-names>RG</given-names></name><name><surname>Seelall</surname><given-names>V</given-names></name><name><surname>Rapoport</surname><given-names>DM</given-names></name></person-group><article-title>Validation of a self-applied unattended monitor for sleep disordered breathing</article-title><source>J Clin Sleep Med</source><year>2008</year><volume>4</volume><issue>1</issue><fpage>26</fpage><lpage>37</lpage><pub-id pub-id-type="pmid">18350959</pub-id></element-citation></ref><ref id="R5"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Vazquez</surname><given-names>JC</given-names></name><name><surname>Tsai</surname><given-names>WH</given-names></name><name><surname>Flemons</surname><given-names>WW</given-names></name><name><surname>Masuda</surname><given-names>A</given-names></name><name><surname>Brant</surname><given-names>R</given-names></name><name><surname>Hajduk</surname><given-names>E</given-names></name><etal/></person-group><article-title>Automated analysis of digital oximetry in the diagnosis of obstructive sleep apnoea</article-title><source>Thorax</source><year>2000</year><volume>55</volume><issue>4</issue><fpage>302</fpage><lpage>7</lpage><pub-id pub-id-type="pmid">10722770</pub-id></element-citation></ref><ref id="R6"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zou</surname><given-names>D</given-names></name><name><surname>Grote</surname><given-names>L</given-names></name><name><surname>Peker</surname><given-names>Y</given-names></name><name><surname>Lindblad</surname><given-names>U</given-names></name><name><surname>Hedner</surname><given-names>J</given-names></name></person-group><article-title>Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography</article-title><source>Sleep</source><year>2006</year><volume>29</volume><issue>3</issue><fpage>367</fpage><lpage>74</lpage><pub-id pub-id-type="pmid">16553023</pub-id></element-citation></ref><ref id="R7"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Westbrook</surname><given-names>PR</given-names></name><name><surname>Levendowski</surname><given-names>DJ</given-names></name><name><surname>Cvetinovic</surname><given-names>M</given-names></name><name><surname>Zavora</surname><given-names>T</given-names></name><name><surname>Velimirovic</surname><given-names>V</given-names></name><name><surname>Henninger</surname><given-names>D</given-names></name><etal/></person-group><article-title>Description and validation of the apnea risk evaluation system: a novel method to diagnose sleep apnea-hypopnea in the home</article-title><source>Chest</source><year>2005</year><volume>128</volume><issue>4</issue><fpage>2166</fpage><lpage>75</lpage><pub-id pub-id-type="pmid">16236870</pub-id></element-citation></ref><ref id="R8"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kapur</surname><given-names>VK</given-names></name><name><surname>Auckley</surname><given-names>DH</given-names></name><name><surname>Chowdhuri</surname><given-names>S</given-names></name><name><surname>Kuhlmann</surname><given-names>DC</given-names></name><name><surname>Mehra</surname><given-names>R</given-names></name><name><surname>Ramar</surname><given-names>K</given-names></name><etal/></person-group><article-title>Clinical Practice Guideline for Diagnostic Testing for Adult Obstructive Sleep Apnea: An American Academy of Sleep Medicine Clinical Practice Guideline</article-title><source>J Clin Sleep Med</source><year>2017</year><volume>13</volume><issue>3</issue><fpage>479</fpage><lpage>504</lpage><pub-id pub-id-type="pmid">28162150</pub-id></element-citation></ref><ref id="R9"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kisch-Wedel</surname><given-names>H</given-names></name><name><surname>Bernreuter</surname><given-names>P</given-names></name><name><surname>Kemming</surname><given-names>G</given-names></name><name><surname>Albert</surname><given-names>M</given-names></name><name><surname>Zwissler</surname><given-names>B</given-names></name></person-group><article-title>Does the estimation of light attenuation in tissue increase the accuracy of reflectance pulse oximetry at low oxygen saturations in vivo?</article-title><source>IEEE Trans Biomed Eng</source><year>2009</year><volume>56</volume><issue>9</issue><fpage>2271</fpage><lpage>9</lpage><pub-id pub-id-type="pmid">19692303</pub-id></element-citation></ref><ref id="R10"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zafar</surname><given-names>S</given-names></name><name><surname>Ayappa</surname><given-names>I</given-names></name><name><surname>Norman</surname><given-names>RG</given-names></name><name><surname>Krieger</surname><given-names>AC</given-names></name><name><surname>Walsleben</surname><given-names>JA</given-names></name><name><surname>Rapoport</surname><given-names>DM</given-names></name></person-group><article-title>Choice of oximeter affects apnea-hypopnea index</article-title><source>Chest</source><year>2005</year><volume>127</volume><issue>1</issue><fpage>80</fpage><lpage>8</lpage><pub-id pub-id-type="pmid">15653966</pub-id></element-citation></ref><ref id="R11"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Davila</surname><given-names>DG</given-names></name><name><surname>Richards</surname><given-names>KC</given-names></name><name><surname>Marshall</surname><given-names>BL</given-names></name><name><surname>O'Sullivan</surname><given-names>PS</given-names></name><name><surname>Osbahr</surname><given-names>LA</given-names></name><name><surname>Huddleston</surname><given-names>RB</given-names></name><etal/></person-group><article-title>Oximeter's acquisition parameter influences the profile of respiratory disturbances</article-title><source>Sleep</source><year>2003</year><volume>26</volume><issue>1</issue><fpage>91</fpage><lpage>5</lpage><pub-id pub-id-type="pmid">12627739</pub-id></element-citation></ref><ref id="R12"><label>12</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cross</surname><given-names>TJ</given-names></name><name><surname>Keller-Ross</surname><given-names>M</given-names></name><name><surname>Issa</surname><given-names>A</given-names></name><name><surname>Wentz</surname><given-names>R</given-names></name><name><surname>Taylor</surname><given-names>B</given-names></name><name><surname>Johnson</surname><given-names>B</given-names></name></person-group><article-title>The Impact of Averaging Window Length on the"Desaturation Indexes during Overnight Pulse Oximetry at High-Altitude"</article-title><source>Sleep</source><year>2015</year><volume>38</volume><issue>8</issue><fpage>1331</fpage><lpage>4</lpage><pub-id pub-id-type="pmid">25581919</pub-id></element-citation></ref><ref id="R13"><label>13</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Stepnowsky</surname><given-names>C</given-names></name><name><surname>Levendowski</surname><given-names>D</given-names></name><name><surname>Popovic</surname><given-names>D</given-names></name><name><surname>Ayappa</surname><given-names>I</given-names></name><name><surname>Rapoport</surname><given-names>DM</given-names></name></person-group><article-title>Scoring accuracy of automated sleep staging from a bipolar electroocular recording compared to manual scoring by multiple raters</article-title><source>Sleep Med</source><year>2013</year><volume>14</volume><issue>11</issue><fpage>1199</fpage><lpage>207</lpage><pub-id pub-id-type="pmid">24047533</pub-id></element-citation></ref><ref id="R14"><label>14</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Flemons</surname><given-names>WW</given-names></name><name><surname>Littner</surname><given-names>MR</given-names></name></person-group><article-title>Measuring agreement between diagnostic devices</article-title><source>Chest</source><year>2003</year><volume>124</volume><issue>4</issue><fpage>1535</fpage><lpage>42</lpage><pub-id pub-id-type="pmid">14555591</pub-id></element-citation></ref><ref id="R15"><label>15</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bland</surname><given-names>JM</given-names></name><name><surname>Altman</surname><given-names>DG</given-names></name></person-group><article-title>Statistical methods for assessing agreement between two methods of clinical measurement</article-title><source>Lancet</source><year>1986</year><volume>1</volume><issue>8476</issue><fpage>307</fpage><lpage>10</lpage><pub-id pub-id-type="pmid">2868172</pub-id></element-citation></ref><ref id="R16"><label>16</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Levendowski</surname><given-names>D</given-names></name><name><surname>Steward</surname><given-names>D</given-names></name><name><surname>Woodson</surname><given-names>BT</given-names></name><name><surname>Olmstead</surname><given-names>R</given-names></name><name><surname>Popovic</surname><given-names>D</given-names></name><name><surname>Westbrook</surname><given-names>P</given-names></name></person-group><article-title>The impact of obstructive sleep apnea variability measured in-lab versus in-home on sample size calculations</article-title><source>Int Arch Med</source><year>2009</year><volume>2</volume><issue>1</issue><fpage>2</fpage><pub-id pub-id-type="pmid">19121211</pub-id></element-citation></ref><ref id="R17"><label>17</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Newell</surname><given-names>J</given-names></name><name><surname>Mairesse</surname><given-names>O</given-names></name><name><surname>Verbanck</surname><given-names>P</given-names></name><name><surname>Neu</surname><given-names>D</given-names></name></person-group><article-title>Is a one-night stay in the lab really enough to conclude? First-night effect and night-to-night variability in polysomnographic recordings among different clinical population samples</article-title><source>Psychiatry Res</source><year>2012</year><volume>200</volume><issue>2&#x02013;3</issue><fpage>795</fpage><lpage>801</lpage><pub-id pub-id-type="pmid">22901399</pub-id></element-citation></ref><ref id="R18"><label>18</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Le Bon</surname><given-names>O</given-names></name><name><surname>Hoffmann</surname><given-names>G</given-names></name><name><surname>Tecco</surname><given-names>J</given-names></name><name><surname>Staner</surname><given-names>L</given-names></name><name><surname>Noseda</surname><given-names>A</given-names></name><name><surname>Pelc</surname><given-names>I</given-names></name><etal/></person-group><article-title>Mild to moderate sleep respiratory events: one negative night may not be enough</article-title><source>Chest</source><year>2000</year><volume>118</volume><issue>2</issue><fpage>353</fpage><lpage>9</lpage><pub-id pub-id-type="pmid">10936124</pub-id></element-citation></ref><ref id="R19"><label>19</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Prasad</surname><given-names>B</given-names></name><name><surname>Usmani</surname><given-names>S</given-names></name><name><surname>Steffen</surname><given-names>AD</given-names></name><name><surname>Van Dongen</surname><given-names>HP</given-names></name><name><surname>Pack</surname><given-names>FM</given-names></name><name><surname>Strakovsky</surname><given-names>I</given-names></name><etal/></person-group><article-title>Short-Term Variability in Apnea-Hypopnea Index during Extended Home Portable Monitoring</article-title><source>J Clin Sleep Med</source><year>2016</year><volume>12</volume><issue>6</issue><fpage>855</fpage><lpage>63</lpage><pub-id pub-id-type="pmid">26857059</pub-id></element-citation></ref><ref id="R20"><label>20</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nigro</surname><given-names>CA</given-names></name><name><surname>Aimaretti</surname><given-names>S</given-names></name><name><surname>Gonzalez</surname><given-names>S</given-names></name><name><surname>Rhodius</surname><given-names>E</given-names></name></person-group><article-title>Validation of the WristOx 3100 oximeter for the diagnosis of sleep apnea/hypopnea syndrome</article-title><source>Sleep Breath</source><year>2009</year><volume>13</volume><issue>2</issue><fpage>127</fpage><lpage>36</lpage><pub-id pub-id-type="pmid">18830731</pub-id></element-citation></ref><ref id="R21"><label>21</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Romem</surname><given-names>A</given-names></name><name><surname>Romem</surname><given-names>A</given-names></name><name><surname>Koldobskiy</surname><given-names>D</given-names></name><name><surname>Scharf</surname><given-names>SM</given-names></name></person-group><article-title>Diagnosis of obstructive sleep apnea using pulse oximeter derived photoplethysmographic signals</article-title><source>J Clin Sleep Med</source><year>2014</year><volume>10</volume><issue>3</issue><fpage>285</fpage><lpage>90</lpage><pub-id pub-id-type="pmid">24634626</pub-id></element-citation></ref><ref id="R22"><label>22</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chiner</surname><given-names>E</given-names></name><name><surname>Signes&#x02013;Costa</surname><given-names>J</given-names></name><name><surname>Arriero</surname><given-names>JM</given-names></name><name><surname>Marco</surname><given-names>J</given-names></name><name><surname>Fuentes</surname><given-names>I</given-names></name><name><surname>Sergado</surname><given-names>A</given-names></name></person-group><article-title>Nocturnal oximetry for the diagnosis of the sleep apnoea hypopnoea syndrome: a method to reduce the number of polysomnographies?</article-title><source>Thorax</source><year>1999</year><volume>54</volume><issue>11</issue><fpage>968</fpage><lpage>71</lpage><pub-id pub-id-type="pmid">10525553</pub-id></element-citation></ref><ref id="R23"><label>23</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Collop</surname><given-names>NA</given-names></name><name><surname>Tracy</surname><given-names>SL</given-names></name><name><surname>Kapur</surname><given-names>V</given-names></name><name><surname>Mehra</surname><given-names>R</given-names></name><name><surname>Kuhlmann</surname><given-names>D</given-names></name><name><surname>Fleishman</surname><given-names>SA</given-names></name><etal/></person-group><article-title>Obstructive sleep apnea devices for out-of-center (OOC) testing: technology evaluation</article-title><source>J Clin Sleep Med</source><year>2011</year><volume>7</volume><issue>5</issue><fpage>531</fpage><lpage>48</lpage><pub-id pub-id-type="pmid">22003351</pub-id></element-citation></ref><ref id="R24"><label>24</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dawson</surname><given-names>A</given-names></name><name><surname>Loving</surname><given-names>RT</given-names></name><name><surname>Gordon</surname><given-names>RM</given-names></name><name><surname>Abel</surname><given-names>SL</given-names></name><name><surname>Loewy</surname><given-names>D</given-names></name><name><surname>Kripke</surname><given-names>DF</given-names></name><etal/></person-group><article-title>Type III home sleep testing versus pulse oximetry: is the respiratory disturbance index better than the oxygen desaturation index to predict the apnoea-hypopnoea index measured during laboratory polysomnography?</article-title><source>BMJ open</source><year>2015</year><volume>5</volume><issue>6</issue><fpage>e007956</fpage></element-citation></ref><ref id="R25"><label>25</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yamaura</surname><given-names>K</given-names></name><name><surname>Nanishi</surname><given-names>N</given-names></name><name><surname>Higashi</surname><given-names>M</given-names></name><name><surname>Hoka</surname><given-names>S</given-names></name></person-group><article-title>Effects of thermoregulatory vasoconstriction on pulse hemoglobin measurements using a co-oximeter in patients undergoing surgery</article-title><source>J Clin Anesth</source><year>2014</year><volume>26</volume><issue>8</issue><fpage>643</fpage><lpage>7</lpage><pub-id pub-id-type="pmid">25439397</pub-id></element-citation></ref><ref id="R26"><label>26</label><element-citation publication-type="journal"><article-title>Sleep-related breathing disorders in adults: recommendations for syndrome definition and measurement techniques in clinical research</article-title><collab>The Report of an American Academy of Sleep Medicine Task Force</collab><source>Sleep</source><year>1999</year><volume>22</volume><issue>5</issue><fpage>667</fpage><lpage>89</lpage><pub-id pub-id-type="pmid">10450601</pub-id></element-citation></ref><ref id="R27"><label>27</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hosselet</surname><given-names>J</given-names></name><name><surname>Ayappa</surname><given-names>I</given-names></name><name><surname>Norman</surname><given-names>RG</given-names></name><name><surname>Krieger</surname><given-names>AC</given-names></name><name><surname>Rapoport</surname><given-names>DM</given-names></name></person-group><article-title>Classification of sleep-disordered breathing</article-title><source>Am J Respir Crit Care Med</source><year>2001</year><volume>163</volume><issue>2</issue><fpage>398</fpage><lpage>405</lpage><pub-id pub-id-type="pmid">11179113</pub-id></element-citation></ref><ref id="R28"><label>28</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Masdeu</surname><given-names>MJ</given-names></name><name><surname>Ayappa</surname><given-names>I</given-names></name><name><surname>Hwang</surname><given-names>D</given-names></name><name><surname>Mooney</surname><given-names>AM</given-names></name><name><surname>Rapoport</surname><given-names>DM</given-names></name></person-group><article-title>Impact of clinical assessment on use of data from unattended limited monitoring as opposed to full-in lab PSG in sleep disordered breathing</article-title><source>J Clin Sleep Med</source><year>2010</year><volume>6</volume><issue>1</issue><fpage>51</fpage><lpage>8</lpage><pub-id pub-id-type="pmid">20191938</pub-id></element-citation></ref><ref id="R29"><label>29</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ayappa</surname><given-names>I</given-names></name><name><surname>Rapaport</surname><given-names>BS</given-names></name><name><surname>Norman</surname><given-names>RG</given-names></name><name><surname>Rapoport</surname><given-names>DM</given-names></name></person-group><article-title>Immediate consequences of respiratory events in sleep disordered breathing</article-title><source>Sleep Med</source><year>2005</year><volume>6</volume><issue>2</issue><fpage>123</fpage><lpage>30</lpage><pub-id pub-id-type="pmid">15716216</pub-id></element-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Fig 1</label><caption><p>ARES&#x02122; and Nonin WristOx<sub>2</sub> devices</p></caption><graphic xlink:href="nihms900967f1"/></fig><fig id="F2" orientation="portrait" position="float"><label>Fig 2</label><caption><p>Histograms showing the percentage of time with poor quality O2 saturation in both devices on the x-axis and the percentage of nights on the y-axis.</p></caption><graphic xlink:href="nihms900967f2"/></fig><fig id="F3" orientation="portrait" position="float"><label>Fig 3</label><caption><p>A: Scatterplot of % time&#x0003c;90%O2Sat for WristOX<sub>2</sub>&#x02122; and ARES&#x02122; for n=310 nights showing significant differences in cumulative O2 desaturation time reported by the devices.(ICC=0.2, 95%CI=0.14&#x02013;0.35, p&#x0003c;0.001) B. Bland Altman plot shows bias and limits of agreement.</p></caption><graphic xlink:href="nihms900967f3"/></fig><fig id="F4" orientation="portrait" position="float"><label>Fig 4</label><caption><p>A: Scatterplot of ODI<sub>Ox2</sub> and AHI4<sub>ARES</sub> for n=310 nights, showing a good correlation (ICC=0.9, 95% CI=0.87&#x02013;0.92, p&#x0003c;0.001) 4B. Bland Altman plot showing bias and limits of agreement.</p></caption><graphic xlink:href="nihms900967f4"/></fig><table-wrap id="T1" position="float" orientation="portrait"><label>Table 1</label><caption><p>Average and standard deviation and median (IQR) for pertinent variables from ARES and Wrist Ox<sub>2</sub></p></caption><table frame="box" rules="all"><thead><tr><th valign="top" rowspan="2" align="left" colspan="1"/><th colspan="2" valign="top" align="left" rowspan="1">All Subjects, all nights (n=310) <break/>Mean&#x000b1;SD <break/>Median (IQR)</th></tr><tr><th valign="top" align="left" rowspan="1" colspan="1">Ares</th><th valign="top" align="left" rowspan="1" colspan="1">Wrist Ox<sub>2</sub></th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>Duration (hours)</bold></td><td align="left" valign="top" rowspan="1" colspan="1">5.8&#x000b1;1.5 <break/>5.6(4.4,6.2)</td><td align="left" valign="top" rowspan="1" colspan="1">6.2&#x000b1;1.8<xref rid="TFN2" ref-type="table-fn">**</xref>
<break/>6.4(4.9,7.4)<xref rid="TFN2" ref-type="table-fn">**</xref></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>AHI4<sub>ARES</sub>/ODI<sub>Ox2</sub></bold></td><td align="left" valign="top" rowspan="1" colspan="1">12.8&#x000b1;14.1 <break/>8.0(3.0,18.0)</td><td align="left" valign="top" rowspan="1" colspan="1">12.1&#x000b1;13.3<xref rid="TFN1" ref-type="table-fn">*</xref>
<break/>7.4(3.4,15.8)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>RDI<sub>ARES</sub></bold></td><td align="left" valign="top" rowspan="1" colspan="1">26.0&#x000b1;16.9 <break/>21.5(13.8,35.0)</td><td align="left" valign="top" rowspan="1" colspan="1">n/a</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>% Time Below 90% O2Sat</bold></td><td align="left" valign="top" rowspan="1" colspan="1">2.6&#x000b1;5.0 <break/>0.5 (.0, 2.6)</td><td align="left" valign="top" rowspan="1" colspan="1">9.6&#x000b1;17.1<xref rid="TFN2" ref-type="table-fn">**</xref>
<break/>2.1 (0.3, 9.7)<xref rid="TFN3" ref-type="table-fn">#</xref></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>Baseline O2Sat (%)(n=295)</bold></td><td align="left" valign="top" rowspan="1" colspan="1">96.2&#x000b1;1.6 <break/>96.6(95.6,97.2)</td><td align="left" valign="top" rowspan="1" colspan="1">92.2&#x000b1;2.1<xref rid="TFN2" ref-type="table-fn">**</xref>
<break/>92.0(91.0,94.0)<xref rid="TFN3" ref-type="table-fn">#</xref></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>% Artifact O2Sat</bold></td><td align="left" valign="top" rowspan="1" colspan="1">14.6&#x000b1;15.9 <break/>8.9(3.6,20.3)</td><td align="left" valign="top" rowspan="1" colspan="1">2.1&#x000b1;7.9<xref rid="TFN2" ref-type="table-fn">**</xref>
<break/>0.7(0.2,1.4)<xref rid="TFN2" ref-type="table-fn">**</xref></td></tr></tbody></table><table-wrap-foot><fn id="TFN1"><label>*</label><p>p&#x0003c;0.05,</p></fn><fn id="TFN2"><label>**</label><p>p&#x0003c;0.01 for comparison between ARES&#x02122; and WristOx<sub>2</sub></p></fn><fn id="TFN3"><label>#</label><p>P&#x0003c;0.001 Wilcoxon signed rank test</p></fn></table-wrap-foot></table-wrap><table-wrap id="T2" position="float" orientation="portrait"><label>Table 2A</label><caption><p>Agreement, sensitivity and specificity when defining disease using cutoffs: (i) AHI4<sub>ARES</sub>&#x02265;5/hr and ODI<sub>Ox2</sub>&#x02265;5; (ii) RDI<sub>ARES</sub>&#x02265;15/hr and AHI4<sub>ARES</sub>&#x02265;5/hr ; (iii) RDI<sub>ARES</sub>&#x02265;15/hr and ODI<sub>Ox2</sub>&#x02265;5</p></caption><table frame="box" rules="all"><thead><tr><th align="left" valign="top" rowspan="1" colspan="1">Definition for OSA diagnosis</th><th align="center" valign="top" rowspan="1" colspan="1">Agreement, Kappa</th><th align="center" valign="top" rowspan="1" colspan="1">Sensitivity</th><th align="center" valign="top" rowspan="1" colspan="1">Specificity</th><th align="center" valign="top" rowspan="1" colspan="1">False Negative Rate</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/><td colspan="2" align="center" valign="top" rowspan="1">Gold Standard ARES</td><td align="center" valign="top" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>ODI<sub>Ox2</sub></bold> &#x02265; <bold>vs AHI4<sub>ARES</sub>&#x02265;5</bold></td><td align="center" valign="top" rowspan="1" colspan="1">82.5%, 0.62</td><td align="center" valign="top" rowspan="1" colspan="1">85.9%</td><td align="center" valign="top" rowspan="1" colspan="1">76.5%</td><td align="center" valign="top" rowspan="1" colspan="1">14%</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>AHI4<sub>ARES</sub></bold> &#x02265;<bold>vs RDI<sub>ARES</sub>&#x02265;15</bold></td><td align="center" valign="top" rowspan="1" colspan="1">84.5%, 0.65</td><td align="center" valign="top" rowspan="1" colspan="1">84.5%</td><td align="center" valign="top" rowspan="1" colspan="1">84.6%</td><td align="center" valign="top" rowspan="1" colspan="1">15.5%</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>ODI<sub>Ox2</sub></bold> &#x02265; <bold>vs RDI<sub>ARES</sub>&#x02265;15</bold></td><td align="center" valign="top" rowspan="1" colspan="1">77.4%, 0.49</td><td align="center" valign="top" rowspan="1" colspan="1">79.0%</td><td align="center" valign="top" rowspan="1" colspan="1">73.6%</td><td align="center" valign="top" rowspan="1" colspan="1">21%</td></tr></tbody></table></table-wrap><table-wrap id="T3" position="float" orientation="portrait"><label>Table 2B</label><caption><p>Agreement, sensitivity and specificity when defining disease using cutoffs: (i) AHI4<sub>ARES</sub>&#x02265;5/hr RDI<sub>ARES</sub>&#x02265;15/hr and ODI<sub>Ox2</sub>&#x02265;5 N1 vs N2, using N1 as the gold standard</p></caption><table frame="box" rules="all"><thead><tr><th valign="top" align="left" rowspan="1" colspan="1">Definition for OSA diagnosis</th><th valign="top" align="center" rowspan="1" colspan="1">Agreement, Kappa</th><th valign="top" align="center" rowspan="1" colspan="1">Sensitivity</th><th valign="top" align="center" rowspan="1" colspan="1">Specificity</th><th valign="top" align="center" rowspan="1" colspan="1">False Negative rate</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/><td colspan="2" align="center" valign="top" rowspan="1">Gold Standard N1</td><td align="center" valign="top" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>AHI4<sub>ARES</sub> &#x02265; N1 vs N2</bold></td><td align="center" valign="top" rowspan="1" colspan="1">73.4%, 0.44</td><td align="center" valign="top" rowspan="1" colspan="1">83%</td><td align="center" valign="top" rowspan="1" colspan="1">60%</td><td align="center" valign="top" rowspan="1" colspan="1">17%</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>ODI<sub>Ox2</sub> &#x02265; N1 vs N2</bold></td><td align="center" valign="top" rowspan="1" colspan="1">83.0%, 0.64</td><td align="center" valign="top" rowspan="1" colspan="1">88.0%</td><td align="center" valign="top" rowspan="1" colspan="1">74.5%</td><td align="center" valign="top" rowspan="1" colspan="1">11.4%</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"><bold>RDI<sub>ARES</sub>&#x02265;15 N1 vs N2</bold></td><td align="center" valign="top" rowspan="1" colspan="1">81.5%, 0.57</td><td align="center" valign="top" rowspan="1" colspan="1">92.8%</td><td align="center" valign="top" rowspan="1" colspan="1">61%</td><td align="center" valign="top" rowspan="1" colspan="1">7%</td></tr></tbody></table></table-wrap><table-wrap id="T4" position="float" orientation="portrait"><label>Table 3</label><caption><p>Comparison of differences between devices and between nights using the same device</p></caption><table frame="box" rules="all"><thead><tr><th valign="top" align="left" rowspan="1" colspan="1">Measurement</th><th valign="top" align="left" rowspan="1" colspan="1">Comparison</th><th valign="top" align="left" rowspan="1" colspan="1"><xref rid="TFN4" ref-type="table-fn">#</xref></th><th valign="top" align="left" rowspan="1" colspan="1">Bias</th><th valign="top" align="left" rowspan="1" colspan="1">Abs diff<break/>Mean&#x000b1;SD or Median (IQR)</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="3" colspan="1"><bold>AHI4<sub>ARES</sub>/ODI<sub>Ox2</sub></bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>ARES vs. WristOx2</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>310</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>0.7&#x000b1;6.1</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>2.5 (1.2, 5.2)</bold></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">N1 vs. N2 ARES</td><td align="left" valign="top" rowspan="1" colspan="1">130</td><td align="left" valign="top" rowspan="1" colspan="1">0.6&#x000b1;9.9</td><td align="left" valign="top" rowspan="1" colspan="1">3.0 (1.0, 6.0)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">N1 vs. N2 WristOx2</td><td align="left" valign="top" rowspan="1" colspan="1">130</td><td align="left" valign="top" rowspan="1" colspan="1">0.7&#x000b1;8.8</td><td align="left" valign="top" rowspan="1" colspan="1">2.5 (1.1, 5.6)</td></tr><tr><td align="left" valign="top" rowspan="3" colspan="1"><bold>%time&#x0003c;90%O2Sat</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>ARES vs. WristOx2</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>310</bold></td><td align="left" valign="top" rowspan="1" colspan="1">&#x02212;<bold>7.0&#x000b1;15.4</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>1.9 (0.4, 7.2)</bold></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">N1 vs. N2 ARES</td><td align="left" valign="top" rowspan="1" colspan="1">130</td><td align="left" valign="top" rowspan="1" colspan="1">0.9&#x000b1;5.1</td><td align="left" valign="top" rowspan="1" colspan="1">0.6 (0.2, 2.9)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">N1 vs. N2 WristOx2</td><td align="left" valign="top" rowspan="1" colspan="1">130</td><td align="left" valign="top" rowspan="1" colspan="1">0.7&#x000b1;15.2</td><td align="left" valign="top" rowspan="1" colspan="1">1.4 (0.3, 6.8)</td></tr><tr><td align="left" valign="top" rowspan="3" colspan="1"><bold>Awake baseline 02Sat</bold><xref rid="TFN5" ref-type="table-fn">*</xref></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>ARES vs. WristOx2</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>295</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>4.0&#x000b1;2.6</bold></td><td align="left" valign="top" rowspan="1" colspan="1"><bold>4.1&#x000b1;2.4</bold></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">N1 vs. N2 ARES</td><td align="left" valign="top" rowspan="1" colspan="1">130</td><td align="left" valign="top" rowspan="1" colspan="1">&#x02212;0.1&#x000b1;2.3</td><td align="left" valign="top" rowspan="1" colspan="1">1.7&#x000b1;1.6</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">N1 vs. N2 WristOx2</td><td align="left" valign="top" rowspan="1" colspan="1">125</td><td align="left" valign="top" rowspan="1" colspan="1">&#x02212;0.9&#x000b1;8.8</td><td align="left" valign="top" rowspan="1" colspan="1">1.5&#x000b1;1.6</td></tr></tbody></table><table-wrap-foot><fn id="TFN4"><label>#</label><p>=Number of comparisons. N1: Night 1; N2=Night</p></fn><fn id="TFN5"><label>*</label><p>O2 saturation during a period in the first 10 minutes of data recording. Stable O2 saturation level could not be reliably obtained from the WristOx2 at the beginning of the study on some nights.</p></fn></table-wrap-foot></table-wrap></floats-group></article>