Research toward direct analysis of quartz dust on filters using FTIR spectroscopy
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Research toward direct analysis of quartz dust on filters using FTIR spectroscopy

Filetype[PDF-2.08 MB]


  • English

  • Details:

    • Description:
      The U.S. Bureau of Mimes is investigating Fourier transform infrared (FTIR) spectroscopy for on- filter quartz analysis of respirable dust. A custom accessory is described for full-face examination of filters utilizing a large-diameter infrared (IR) beam. The accessory positions samples to match diameters with that of the diverging analytical beam. Sample absorbance is then measured. With nonuniform deposition of dust on collection filters being a major issue for such analyses, this approach is the most direct way to accomplish sample area averaging. The approach is unconventional since it utilizes large-beam geometries instead of the usually desired minimized beam dimensions. The issues and problems involved in the analysis of quartz on a filter matrix are discussed. Absorption bands chosen, light-scattering effects, curved baselines, random noise, interference fringes, and possible solutions to technical difficulties are the topics covered. The more significant findings include a 20-pg detection limit for quartz when the custom accessory is used and minimal occurrence of light-scattering effects at low wavenumbers. The custom accessory performance was satisfactory and merits further work. With continued research, an on-filter method for quartz analysis of respirable dusts seems achievable.
    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov