Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

on mobile refuge alternative temperature

Filetype[PDF-840.40 KB]



Details:

  • Alternative Title:
    Min Eng
  • Description:
    Federal regulations require the installation of refuge alternatives (RAs) in underground coal mines. Mobile RAs have a limited ability to dissipate heat, and heat buildup can lead to a life-threatening condition as the RA internal air temperature and relative humidity increase. The U.S. National Institute for Occupational Safety and Health (NIOSH) performed heat testing on a 10-person tent-type training RA and contracted ThermoAnalytics Inc. to develop a validated thermal simulation model of the tested RA. The model was used to examine the effects of the constant mine strata temperature assumption, initial mine air temperature, initial mine strata surface temperature (MSST), initial mine strata temperature at depth (MSTD) and mine strata thermal behavior on RA internal air temperature using 117 W (400 Btu/h) of sensible heat input per simulated miner. For the studied RA, when the mine strata temperature was treated as a constant, the final predicted RA internal air temperature was 7.1°C (12.8°F) lower than it was when the mine strata thermal behavior was included in the model. A 5.6°C (10.0°F) increase in the initial MSST resulted in a 3.9°C (7.1°F) increase in the final RA internal air temperature, whereas a 5.6°C (10°F) increase in the initial MSTD yielded a 1.4°C (2.5°F) increase in the final RA internal air temperature. The results indicate that mine strata temperature increases and mine strata initial temperatures must be accounted for in the physical testing or thermal simulations of RAs.
  • Subjects:
  • Pubmed ID:
    28867830
  • Pubmed Central ID:
    PMC5580723
  • Document Type:
  • Collection(s):
  • Main Document Checksum:
  • File Type:

You May Also Like

Checkout today's featured content at stacks.cdc.gov