i

Evaluation of the point-of-care Becton Dickinson Veritor™ Rapid influenza diagnostic test in Kenya, 2013–2014

Filetype[PDF-2.46 MB]


  • English

  • Details:

    • Alternative Title:
      BMC Infect Dis
    • Description:
      Background

      We evaluated the performance of the Becton Dickinson Veritorâ„¢ System Flu A + B rapid influenza diagnostic test (RIDT) to detect influenza viruses in respiratory specimens from patients enrolled at five surveillance sites in Kenya, a tropical country where influenza seasonality is variable.

      Methods

      Nasal swab (NS) and nasopharyngeal (NP)/oropharyngeal (OP) swabs were collected from patients with influenza like illness and/or severe acute respiratory infection. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the RIDT using NS specimens were evaluated against nasal swabs tested by real time reverse transcription polymerase chain reaction (rRT-PCR). The performance parameter results were expressed as 95% confidence intervals (CI) calculated using binomial exact methods, with P < 0.05 considered significant. Two-sample Z tests were used to test for differences in sample proportions. Analysis was performed using SAS software version 9.3.

      Results

      From July 2013 to July 2014, 3,569 patients were recruited, of which 78.7% were aged <5 years. Overall, 14.4% of NS specimens were influenza-positive by RIDT. RIDT overall sensitivity was 77.1% (95% CI 72.8–81.0%) and specificity was 94.9% (95% CI 94.0–95.7%) compared to rRT-PCR using NS specimens. RIDT sensitivity for influenza A virus compared to rRT-PCR using NS specimens was 71.8% (95% CI 66.7–76.4%) and was significantly higher than for influenza B which was 43.8% (95% CI 33.8–54.2%). PPV ranged from 30%–80% depending on background prevalence of influenza.

      Conclusion

      Although the variable seasonality of influenza in tropical Africa presents unique challenges, RIDTs may have a role in making influenza surveillance sustainable in more remote areas of Africa, where laboratory capacity is limited.