Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Comparison of Lead and Tin Concentrations in Air at a Solder Manufacturer from the Closed-Face 37-mm Cassette With and Without a Custom Cellulose-Acetate Cassette Insert

Filetype[PDF-725.51 KB]



Details:

  • Alternative Title:
    J Occup Environ Hyg
  • Description:
    A polyvinyl chloride (PVC) cassette insert with PVC filter (ACCU-CAP) in a 37-mm closed-face cassette (CFC) was designed for gravimetric analysis. A customized version of the ACCU-CAP, also to be used in the CFC, was manufactured from an acid-digestible cellulose-acetate cassette insert joined to a mixed cellulose ester (MCE) filter for wet chemical analysis. The aim of this study was to compare metal particle concentrations as sampled by the customized insert (CI) in a CFC sampler with the traditional sampling method using only a MCE filter in the CFC. Thirty-nine personal and 13 area samples were taken using paired filter-based CFC and the CI in CFC samplers at a solder manufacturing plant. The CI was removed from its CFC, and digested and analyzed as a whole. The MCE filter from the typical CFC was removed for analysis and then the interior of the cassette was wiped with Ghost Wipe for a separate analysis. The MCE filter only, Ghost Wipe, and CI were separately dissolved in heated nitric acid for ICP-MS analysis. Overall, the geometric mean concentration of the filter-only (FO) samples was considerably lower than that of the CI samples, by 53% for lead and 32% for tin. However, if the FO analysis was added to the corresponding Ghost Wipe analysis, i.e., filter+interior wipe (FW), the geometric mean concentrations of the FW results were similar to those of the CI results (by 113% for lead and 98% for tin). For both lead and tin the comparison of (log-transformed) metal concentrations between the FW and CI results showed no statistically significant difference (p-value = 0.3009 for lead and 0.800 for tin), while the comparison between the FO and CI results shows statistically significant differences (all p-values < 0.05). In conclusion, incorporating the sampler internal non-filter deposits by wiping or use of an internal filter capsule gave higher results than analyzing only the filter. Close agreement between the two methods of including non-filter deposits is an indication of general equivalency.
  • Pubmed ID:
    24856841
  • Pubmed Central ID:
    PMC4706070
  • Document Type:
  • Collection(s):
  • Main Document Checksum:
  • File Type:

You May Also Like

Checkout today's featured content at stacks.cdc.gov