Patients with end stage renal diseases (ESRD) undergoing hemodialysis (HD) have high morbidity and mortality due to multiple causes; one of which is dramatically higher fall rates than the general population. In spite of the multiple efforts aiming to decrease the high mortality and improve quality of life in ESRD patients, limited success has been achieved. If adequate interventions for fall prevention are to be achieved, the functional and mobility mechanisms consistent with falls in this population must be understood. Human movements such as sit-to-walk (STW) tasks are clinically significant, and analysis of these movements provides a meaningful evaluation of postural and locomotor performance in elderly patients with functional limitations indicative of fall risks. In order to assess the effects of HD therapy on fall risks, 22 sessions of both pre- and post-HD measurements were obtained in six ESRD patients utilizing customized inertial measurement units (IMU). IMU signals were denoised using ensemble empirical mode decomposition and Savistky-Golay filtering methods to detect relevant events for identification of STW phases. The results indicated that patients were slower to get out of the chair (as measured by trunk flexion angular accelerations, time to peak trunk flexion, and overall STW completion time) following the dialysis therapy session. STW is a frequent movement in activities of daily living, and HD therapy may influence the postural and locomotor control of these movements. The analysis of STW movement may assist in not only assessing a patient’s physical status, but in identifying HD-related fall risk as well. This preliminary study presents a non-invasive method of kinematic measurement for early detection of increased fall risk in ESRD patients using portable inertial sensors for out-patient monitoring. This can be helpful in understanding the pathogenesis better, and improve awareness in health care providers in targeting interventions to identify individuals at risk for fall.
Fall accidents pose a significant threat to older adults with End Stage Renal Disease undergoing HD therapy. In 2009, approximately 2.2 million nonfatal fall injuries were reported among older adults and were treated in emergency departments, and more than 581,000 of these patients were hospitalized.
To quantify the mechanisms associated with HD therapy on fall risk between pre- and post-HD, baseline fall risk factors and differential effects of dialysis therapy (pre and post-HD) need to be determined. An objective method for assessing fall risk using body worn kinematic sensors and the Timed Up and Go (TUG) Test has been reported previously by several authors.
Sit-to-walk is a frequent movement in activities of daily living and its performance helps in both physical and mental assessment. STW is a complex sequential postural locomotor task that consists of two components: sit-to-stand (STS) and gait initiation (GI). Both tasks are merged at the point of “seat-off” in healthy young adults, where the overlap of STS and GI around “seat-off” is essential to exploit the inertial characteristics of both tasks.
The purpose of this preliminary study was to compare intra-individual differences in STW parameters using a validated non-invasive mobile sensor technology to accurately and unobtrusively measure fall risks associated with HD therapy in the dialysis clinic. To accommodate the dialysis clinical setting, and bearing in mind the post-dialysis fatigue conditions of patients, inertial measurement units were utilized, in lieu of a motion capture system and forceplates, to detect postural and gait events. The overall aim of this investigation was to evaluate the effects of HD on STW parameters and fall risk assessment.
We postulate that the HD therapy process, a treatment for ESRD patients, is a risk factor for falls in this population and, will likely influence STW parameters, and subsequent event timing sequences. The present study will provide an initial assessment of the inherent effects of HD treatment on fall risks in this population for the first time, and may provide a better rationale for continuous monitoring in the future (i.e., 22 h post-HD period).
Data was collected over the course of 5 months in the Kidney Center hemodialysis facility section of the Nephrology Division at the University of Virginia. Six ESRD patients (54 ± 4 years) consisting of 4 females and two males, were tested with each HD treatment session lasting 4 h. All participants had given written consent in accordance to the Virginia Tech and the University of Virginia IRB prior to participation. Blood pressure (BP) was monitored continuously throughout the dialysis treatments, while sitting and standing BP readings were taken immediately before and after each trial to check orthostatic BP. All patients were ambulatory, free of orthopedic injury, did not require any assistive devices, and were able to rise from a chair without assistance.
TEMPO (Technology-Enabled Medical Precision Observation) which was manufactured in collaboration with the research team of the University of Virginia
Participants wore five IMU units (one on each lateral side of shank, and one on the sacrum, one on each wrist). The shank IMU units (TEMPO) were affixed at the lateral sides of each shank such that the
The data was post processed using custom software written in MATLAB (MATLAB version 6.5.1, 2003, computer software, The MathWorks Inc., Natick, Massachusetts). empirical mode decomposition (EMD)
Let
Ensemble empirical mode decomposition (EEMD), is another approach which consists of sifting an ensemble of white noise-added signal and treats its mean as the true result.
Comparisons between pre- and post-HD conditions were performed using paired
All six HD patients were able to complete the experiment trials without falling and without any postural hypotensive episodes. Although, all six patients experienced a drop in systolic blood pressure upon standing (between 10–15 mmHg), there was no report of postural hypotension episodes (i.e., none of them complained for any kind of dizziness or unsteadiness during upright standing). Percentage change in pre-dialysis systolic BP was 1.98 ± 0.81% and for post-dialysis systolic BP was 0.58 ± 0.9% for standing among the patients.
Time to generate peak flexion velocity was defined as the time between the occurrence of peak flexion angular velocity event (E2) and the STW initiation event (E1) (
In this preliminary study we aim to understand the progression of movement from static posture to dynamic walking in pre-dialysis and post-dialysis conditions to assess fall risks associated with HD therapy. We found that HD therapy decreased STW parameters such as flexion acceleration prior to seat-off, and increased subsequent event timing sequences and thus may influence the risk of falls. Magnan
Diminished STW and consequent balance complications can be symptomatic of decreased muscular strength, motor coordination, and inducement of post-dialysis fatigue. Additionally, dialysis engenders change in biochemical parameters responsible for neuromuscular performance including (1) rapid changes in calcium concentration affecting muscle function; (2) acid-base balance affecting neuromuscular function.
STS, which is also a component of STW, depends on a multitude of sensorimotor, balance, psychological factors
A reduction in a person’s ability to simultaneously lift and transfer the body from quiet sitting to walking, can be a critical limiting factor for the quality of life. More information on STW movement characteristics may help in understanding these post-dialysis functional problems. Healthy young adults typically take about 0.43–0.53 s in phase I (movement initiation to seat-off) and healthy older adults take nearly 0.41–0.59 s,
An important part of this study was the identification of distinct events during STW movements. The identified events were consistent for all subjects and were ordered in following sequences: (1) Initiation (2) Peak Flexion Velocity (3) Seat Off Event (4) Peak Extension Velocity (5) GI (6) Swing Foot Toe-Off (7) Swing Foot Heel-Strike (8) Stance Foot Toe-Off (9) Stance Foot Heel-Strike (
A similar work by Kerr
Conclusions based on this study should be considered in the context of its limitations. Although every attempt was made to standardize the patient’s movement by using a standard arm-chair of fixed height, patients used backrest to sit with their thighs and foot parallel to each other. We did not record the strategy of rising from chair but was determined by post-processing IMU data placed on wrists. Although this does not alter the natural pattern of movement, the magnitude of trunk angular velocity and initial flexion acceleration are different in each strategy, thus patients had been instructed to raise themselves using arm-rest always. Previous studies on STW have defined GI as the peak in medio-lateral shear forces, when patient’s feet are placed on force plates; and were not sensitive enough to get detected in most of the trials. However, in our simplified approach, combining both extension and unloading phases, we lose the information applicable to gait commencement in the STW sequence. In addition, our study lacks control data; thus, the experimental design is limited to whether impairment of STW is a result of sitting in a chair for 4 h. However, our data did not show systematic improvements in post-HD trials, permitting us to rule out the idea that impairment in the STW movement was simply due to sitting in a chair for 4 h. Similarly, the results in our preliminary study cannot be generalized for the elderly ESRD population, because we only tested six patients and their average age was less than 60 years. Lastly, to reduce intra-subject variability, we did not conduct warm-up trials of the task in both pre- and post-HD data collection.
The present study demonstrates the potential of an IMU to measure STW performance to detect and quantify subtle abnormalities in mobility, balance, coordination and functional abilities. In clinical settings, the mobility parameters and characteristics examined in this study could provide further insights into motor performance of patients after dialysis treatment and may provide an evaluation standard for fall risk in these patients. The clinical utility and relevance for using IMU’s is in its continuous (approximately 22 h) data acquisition and analysis after dialysis treatment, because HD is a cyclic therapy (considering thrice weekly HD regimen) and time for occurrence of abnormal postural transitions resulting in falls is uncertain. Our results indicate that ESRD patients rise slower after dialysis; this may be due to combined deterioration effects of dialysis on neuromuscular function and reduced strength. STW analysis could improve our ability to identify HD patients at risk of falls, to document effects of dialysis therapy in this perspective, and to assess the response and benefits with other therapeutic interventions. As fall interventions are effective, screening HD patients for falls may become important. On identification of specific component of STW movement which is problematic, physicians may be able to refine the rehabilitation programme. Currently, subjective ratings of functional movements are standard feature of clinical mobility tests. This study has potential to shift current clinical mobility assessment paradigms with an immediate impact because this type of objective assessments (afforded by the novel mobile sensors) can be easily implemented inmost clinical settings. The results of this preliminary study have little implications for targeted rehabilitation programs in patients after HD therapy; however, future research with more participants may help in designing specialized rehabilitation programs. Furthermore, this study enhances understanding of daily activities such as STW movement and provides a model for screening patients at risk of fall.
This research was supported by the NSF (Grant #CBET-0756058) and NIOSH (grant #CDC/NIOSHR01-OH009222). Additionally, supported by the NIH (L30-AG022963-04/NIH HHS/United States). Authors are also thankful to Sharon (Lisa) Johnson, Adam Barth and Xiaoyue Zhang for data collection.
(a) Schematic diagram of procedure for signal conditioning and STW phase classification. (b) Schematic diagram of denoising signals by EEMD-Golay method.
Three phases of STW (1) Flexion momentum phase, (2) Combined extension and unloading phase, and (3) Stance phase and eight postural transition and gait events detected using denoised IMU signals (E1–E8).
Typical example of gyroscope (Gyro X) and accelerometer (Acc Z) signals of a sample subject (IMU located at sacrum). Event detection: (a) STW Initiation (E1), Peak flexion angular velocity (E2), Peak extension angular velocity (E4) and (b) seat off event (E3).
Typical examples of gyroscope (Gyro Z) signals of a sample subject (IMU located at lateral side of both shanks). Event detection from swing (left) and stance (left) foot sensors. (a) swing foot and corresponding toe off event (E5) and heel strike event (E6). (b) stance foot and corresponding toe off event (E7) and heel strike event (E8).
Mean (±SD) changes of blood pressure during sitting and standing for pre- and post-dialysis.
Six HD patients participated in the study and 22 pre and post HD trials were collected.
| Participant | Days | HD | Peak acceleration | Peak flexion | Peak extension | Initial Flexion |
|---|---|---|---|---|---|---|
| P1 | 1 | Pre | 1.17 (0.03) | 101.01 (35.2) | 64.78 (7.39) | 4.84 (1.99) |
| Post | 0.84 (0.74) | 77.48 (9.44) | 90.76 (6.02) | 0.23 (0.04) | ||
| P2 | 1 | Pre | 0.29 (0.07) | 78.94 (46.81) | 147.86 (35.03) | 3.26 (2.27) |
| Post | 0.76 (0) | 65.17 (0) | 61.07 (0) | 1.60 (0) | ||
| 2 | Pre | 0.43 (0) | 64.11 (0) | 75.70 (0) | 1.45 (0) | |
| Post | 0.31 (0.26) | 97.44 (41.89) | 33.76 (29.72) | 1.36 (0.52) | ||
| 3 | Pre | 0.49 (0) | 83.60 (0) | 73.01 (0) | 1.72 (0) | |
| Post | 0.18 (0) | 124.91 (0) | 8.89 (0) | 2.17 (0) | ||
| 4 | Pre | 0.48 (0.20) | 69.41 (18.85) | 58.05 (2.11) | 2.45 (0.91) | |
| Post | 0.54 (0) | 66.46 (0) | 51.59 (0) | 1.54 (0) | ||
| 5 | Pre | 0.55 (0.12) | 43.28 (27.95) | 72.38 (10.76) | 1.77 (0.86) | |
| Post | 0.59 (0.10) | 69.54 (2.84) | 60.34 (5.84) | 2.18 (0.13) | ||
| 6 | Pre | 0.75 (0.01) | 71.35 (1.99) | 43.76 (7.37) | 2.84 (0.02) | |
| Post | 0.42 (0.04) | 58.34 (6.88) | 71.43 (17.04) | 2.16 (0.94) | ||
| P3 | 1 | Pre | 0.51 (0.05) | 65.01 (8.55) | 54.40 (12.19) | 2.26 (0.72) |
| Post | 0.65 (0.06) | 46.59 (14.27) | 32.52 (10.48) | 1.75 (0.28) | ||
| 2 | Pre | 0.71 (0.05) | 71.86 (7.84) | 52.08 (6.55) | 2.46 (0.26) | |
| Post | 0.79 (0.03) | 53.96 (17.24) | 66.91 (11.26) | 2.31 (0.33) | ||
| 3 | Pre | 0.83 (0.07) | 92.13 (23.78) | 47.65 (2.74) | 3.20 (1.45) | |
| Post | 0.79 (0.01) | 44.61 (3.05) | 30.35 (4.30) | 0.64 (0.22) | ||
| 4 | Pre | 0.81 (0) | 85.01 (0) | 49.08 (0) | 3.78 (0) | |
| Post | 0.67 (0.04) | 66.51 (5.34) | 28.99 (4.63) | 2.05 (0.55) | ||
| 5 | Pre | 0.77 (0.02) | 69.48 (8.35) | 58.03 (5.43) | 3.08 (1.44) | |
| Post | 0.77 (0) | 29.02 (0) | 24.65 (0) | 0.81 (0) | ||
| 6 | Pre | 0.66 (0) | 74.01 (0) | 34.19 (0) | 2.74 (0) | |
| Post | 0.54 (0.09) | 47.62 (25.54) | 23.68 (7.54) | 1.39 (0.66) | ||
| P4 | 1 | Pre | 0.81 (0.05) | 92.94 (13.54) | 41.35 (8.43) | 3.28 (0.48) |
| Post | 0.80 (0.03) | 73.12 (1.20) | 53.67 (4.01) | 2.02 (0.16) | ||
| 2 | Pre | 0.73 (0.04) | 84.98 (13.14) | 39.62 (9.78) | 3.01 (0.61) | |
| Post | 0.82 (0.04) | 85.98 (14.19) | 63.11 (7.54) | 2.72 (0.16) | ||
| 3 | Pre | 0.70 (0) | 66.32 (0) | 34.32 (0) | 3.22 (0) | |
| Post | 0.77 (0.02) | 97.22 (17.51) | 53.81 (15.56) | 3.55 (1.16) | ||
| 4 | Pre | 0.76 (0) | 59.15 (0) | 29.72 (0) | 2.02 (0) | |
| Post | 0.75 (0.02) | 87.02 (1.35) | 48.91 (3.19) | 2.50 (0.53) | ||
| 5 | Pre | 0.63 (0.07) | 70.63 (4.52) | 43.02 (20.71) | 2.80 (0.41) | |
| Post | 0.74 (0.05) | 105.17 (8.10) | 42.27 (5.17) | 4.46 (0.30) | ||
| P5 | 1 | Pre | 1.02 (0.08) | 67.55 (5.45) | 71.64 (8.27) | 2.05 (0.35) |
| Post | 0.91 (0.28) | 71.46 (19.11) | 67.04 (6.37) | 2.12 (0.79) | ||
| 2 | Pre | 1.10 (0.07) | 78.38 (6.18) | 69.77 (25.51) | 2.27 (0.21) | |
| Post | 1.04 (0.08) | 96.91 (14.80) | 61.39 (8.98) | 3.43 (1.36) | ||
| P6 | 1 | Pre | 1.21 (0.04) | 209.19 (44.66) | 122.44 (34.57) | 10.35 (4.44) |
| Post | 1.17 (0.06) | 217.13 (21.89) | 116.15 (20.97) | 10.03 (0.74) | ||
| 2 | Pre | 1.18 (0.06) | 142.15 (19.75) | 79.04 (23.47) | 6.37 (1.83) | |
| Post | 1.22 (0.06) | 126.37 (9.49) | 99.64 (5.62) | 3.67 (0.75) |
The values indicated are mean values of three trials and standard deviation in parenthesis.
Time interval to reach peak flexion and extension events and the time taken to complete three phases and complete STW task.
| Time between events | Pre HD (s) | Post HD (s) | |
|---|---|---|---|
| STW initiation to peak flexion(E1–E2) | 0.47 (0.04) | 0.80 (0.07) | 0.03* |
| STW initiation to peak extension (E1–E4) | 1.53 (0.19) | 1.91 (0.21) | 0.02* |
| Phase 1 (E1–E3) | 1.04 (0.14) | 1.36 (0.17) | 0.04* |
| Phase 2 (E5–E3) | 0.84 (0.14) | 0.79 (0.00) | 0.72 |
| Phase 3 (E7–E5) | 0.57 (0.07) | 0.73 (0.04) | 0.14 |
| STW completion (E7–E1) | 2.46 (0.57) | 2.90 (0.89) | 0.04* |
| First double support (E7–E6) | 0.14 (0.10) | 0.29 (0.32) | 0.24 |
The values indicated are mean values of three trials and standard deviation in parenthesis.