<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">0147621</journal-id><journal-id journal-id-type="pubmed-jr-id">3548</journal-id><journal-id journal-id-type="nlm-ta">Environ Res</journal-id><journal-id journal-id-type="iso-abbrev">Environ. Res.</journal-id><journal-title-group><journal-title>Environmental research</journal-title></journal-title-group><issn pub-type="ppub">0013-9351</issn><issn pub-type="epub">1096-0953</issn></journal-meta><article-meta><article-id pub-id-type="pmid">23127494</article-id><article-id pub-id-type="pmc">3582809</article-id><article-id pub-id-type="doi">10.1016/j.envres.2012.10.004</article-id><article-id pub-id-type="manuscript">NIHMS442038</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Seasonal concentrations and determinants of indoor particulate matter in a low-income community in Dhaka, Bangladesh</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Gurley</surname><given-names>Emily S.</given-names></name><xref ref-type="aff" rid="A1">a</xref><xref ref-type="aff" rid="A2">b</xref><email>egurley@icddrb.org</email></contrib><contrib contrib-type="author"><name><surname>Salje</surname><given-names>Henrik</given-names></name><xref ref-type="aff" rid="A2">b</xref><email>hsalje@jhsph.edu</email></contrib><contrib contrib-type="author"><name><surname>Homaira</surname><given-names>Nusrat</given-names></name><xref ref-type="aff" rid="A1">a</xref><email>nhomaira@icddrb.org</email></contrib><contrib contrib-type="author"><name><surname>Ram</surname><given-names>Pavani K.</given-names></name><xref ref-type="aff" rid="A3">c</xref><email>pkram@buffalo.edu</email></contrib><contrib contrib-type="author"><name><surname>Haque</surname><given-names>Rashidul</given-names></name><xref ref-type="aff" rid="A1">a</xref><email>rhaque@icddrb.org</email></contrib><contrib contrib-type="author"><name><surname>Petri</surname><given-names>William A.</given-names><suffix>Jr.</suffix></name><xref ref-type="aff" rid="A4">d</xref><email>wap3g@virginia.edu</email></contrib><contrib contrib-type="author"><name><surname>Bresee</surname><given-names>Joseph</given-names></name><xref ref-type="aff" rid="A5">e</xref><email>jsb6@cdc.gov</email></contrib><contrib contrib-type="author"><name><surname>Moss</surname><given-names>William J.</given-names></name><xref ref-type="aff" rid="A2">b</xref><email>wmoss@jhsph.edu</email></contrib><contrib contrib-type="author"><name><surname>Luby</surname><given-names>Stephen P.</given-names></name><xref ref-type="aff" rid="A1">a</xref><xref ref-type="aff" rid="A5">e</xref><email>sluby@icddrb.org</email></contrib><contrib contrib-type="author"><name><surname>Breysse</surname><given-names>Patrick</given-names></name><xref ref-type="aff" rid="A2">b</xref><email>pbreysse@jhsph.edu</email></contrib><contrib contrib-type="author"><name><surname>Azziz-Baumgartner</surname><given-names>Eduardo</given-names></name><xref ref-type="aff" rid="A1">a</xref><xref ref-type="aff" rid="A5">e</xref><email>eha9@cdc.gov</email></contrib></contrib-group><aff id="A1"><label>a</label>International Centre for Diarrheal Diseases Research, Bangladesh (icddr,b), 68 Shaheed Tajuddin Ahmed Sarani, Mohakhali, Dhaka-1212, Bangladesh</aff><aff id="A2"><label>b</label>Johns Hopkins Bloomberg School of Public Health, 615 N. Wolfe Street, Baltimore, Maryland, 21205 USA</aff><aff id="A3"><label>c</label>University at Buffalo School of Public Health and Health Professions, 401 Kimball Tower, 3435 Main Street, Buffalo, New York, 14214 USA</aff><aff id="A4"><label>d</label>University of Virginia, 345 Crispell Drive, Charlottesville, Virginia, 22908 USA</aff><aff id="A5"><label>e</label>US Centers for Disease Control and Prevention (CDC), 1600 Clifton Road, Atlanta, Georgia, 30333 USA</aff><author-notes><corresp id="FN1">Corresponding author: Emily S. Gurley, Centre for Communicable Diseases, International Centre for Diarrheal Diseases Research, Bangladesh (icddr,b), 68 Shaheed Tajuddin Ahmed Sarani, Mohakhali, Dhaka-1212, Bangladesh; <email>egurley@icddrb.org</email>; cell phone: +88-01715-201-409; fax: +88-02-882-3963</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>15</day><month>2</month><year>2013</year></pub-date><pub-date pub-type="epub"><day>03</day><month>11</month><year>2012</year></pub-date><pub-date pub-type="ppub"><month>2</month><year>2013</year></pub-date><pub-date pub-type="pmc-release"><day>01</day><month>2</month><year>2014</year></pub-date><volume>121</volume><fpage>11</fpage><lpage>16</lpage><permissions><copyright-statement>&#x000a9; 2012 Elsevier Inc. All rights reserved.</copyright-statement><copyright-year>2012</copyright-year></permissions><abstract><p id="P2">Indoor exposure to particulate matter (PM) increases the risk of acute lower respiratory tract infections, which are the leading cause of death in young children in Bangladesh. Few studies, however, have measured children&#x02019;s exposures to indoor PM over time. The World Health Organization recommends that daily indoor concentrations of PM less than 2.5 &#x003bc;m in diameter (PM<sub>2.5</sub>) not exceed 25 &#x003bc;g/m<sup>3</sup>. This study aimed to describe the seasonal variation and determinants of concentrations of indoor PM<sub>2.5</sub> in a low-income community in urban Dhaka, Bangladesh. PM<sub>2.5</sub> was measured in homes monthly during May 2009 to April 2010. We calculated the time-weighted average, 90<sup>th</sup> percentile PM<sub>2.5</sub> concentrations and the daily hours PM<sub>2.5</sub> exceeded 100 &#x003bc;g/m<sup>3</sup>. Linear regression models were used to estimate the associations between fuel use, ventilation, indoor smoking, and season to each metric describing indoor PM<sub>2.5</sub> concentrations. Time-weighted average PM<sub>2.5</sub> concentrations were 190 &#x003bc;g/m<sup>3</sup> (95% CI 170 &#x02013; 210). Sixteen percent of 258 households primarily used biomass fuels for cooking and PM<sub>2.5</sub> concentrations in these homes had average concentrations 75 &#x003bc;g/m<sup>3</sup> (95% CI 56 &#x02013; 124) greater than other homes. PM<sub>2.5</sub> concentrations were also associated with burning both biomass and kerosene, indoor smoking, and ventilation, and were more than twice as high during winter than during other seasons. Young children in this community are exposed to indoor PM<sub>2.5</sub> concentrations 7 times greater than those recommended by World Health Organization guidelines. Interventions to reduce biomass burning could result in a daily reduction of 75 &#x003bc;g/m<sup>3</sup> (40%) in time-weighted average PM<sub>2.5</sub> concentrations.</p></abstract><kwd-group><kwd>particulate matter</kwd><kwd>Bangladesh</kwd><kwd>indoor air</kwd><kwd>biomass</kwd><kwd>urban health</kwd></kwd-group><funding-group><award-group><funding-source country="United States">National Institute of Allergy and Infectious Diseases Extramural Activities : NIAID</funding-source><award-id>R01 AI043596 || AI</award-id></award-group></funding-group></article-meta></front><body><sec id="S1"><title>Introduction</title><p id="P3">Acute lower respiratory tract infections, including pneumonia, are the leading cause of death in children aged &#x0003c;5 years in Bangladesh (<xref rid="R5" ref-type="bibr">Baqui et al. 2001</xref>; <xref rid="R9" ref-type="bibr">Black et al. 2003</xref>). An estimated 25,000 Bangladeshi children died from acute lower respiratory infections in 2008 (<xref rid="R10" ref-type="bibr">Black et al. 2010</xref>). A recent meta-analysis of epidemiologic studies found that children &#x0003c;5 years of age with exposure to smoke from biomass fires in and around the household were 1.8 (95% confidence interval [95% CI] 1.3 &#x02013; 2.2) times more likely to experience acute lower respiratory infections than children without this exposure (<xref rid="R18" ref-type="bibr">Dherani et al. 2008</xref>). The World Health Organization estimated that 32,000 childhood deaths from pneumonia were attributable to indoor exposures to biomass smoke in Bangladesh in 2001 (<xref rid="R4" ref-type="bibr">Anon. 2007</xref>).</p><p id="P4">Biomass fuels burn inefficiently and smoke from biomass combustion releases fine particles into the air which can be breathed into the lower lung (<xref rid="R26" ref-type="bibr">Naeher et al. 2007</xref>). Although households in low-income countries frequently burn biomass for cooking or heating (<xref rid="R4" ref-type="bibr">Anon. 2007</xref>), little is known about particulate matter (PM) concentrations in these homes. Until recently, most standard air quality monitors capable of measuring PM concentrations were large, expensive machines that required technical expertise to deploy (<xref rid="R30" ref-type="bibr">Smith 2002</xref>). Therefore, most epidemiologic studies used proxy PM exposure measurements, such as the type of cooking fuel or estimates of the amount of time the child spends near the cooking fire (<xref rid="R18" ref-type="bibr">Dherani et al. 2008</xref>; <xref rid="R21" ref-type="bibr">Ezzati and Kammen 2002</xref>). These proxy exposures were consistently associated with an increased risk of acute lower respiratory infections in children, suggesting that they are useful for discriminating between levels of exposure (<xref rid="R18" ref-type="bibr">Dherani et al. 2008</xref>). However, these proxy measures of exposure had major limitations (<xref rid="R21" ref-type="bibr">Ezzati and Kammen 2002</xref>). First, proxy exposures do not allow for comparison of exposure to PM between countries or study sites. For example, if burning wood for cooking is associated with an increased risk of acute lower respiratory infections in two studies, this provides no information about how exposures to PM may differ between those study populations. Second, these proxy measurements provide little information about how PM exposures differ between participants within the study, only whether or not the difference resulted in significant increases in risk. Third, there may be seasonal variations in fuel use or other household determinants of PM concentrations which may not be accurately captured by interviews, making it difficult to capture seasonal variations in exposure.</p><p id="P5">The few published studies describing measured indoor PM in low-income countries are limited by small sample sizes, cross-sectional design, and/or absence of detailed analyses that limit interpretations of seasonal variation and determinants of indoor PM concentrations (<xref rid="R21" ref-type="bibr">Ezzati and Kammen 2002</xref>; <xref rid="R16" ref-type="bibr">Dasgupta et al. 2006a</xref>, <xref rid="R17" ref-type="bibr">b</xref>; <xref rid="R20" ref-type="bibr">Ezzati and Kammen 2001</xref>; <xref rid="R6" ref-type="bibr">Bautista et al. 2009</xref>). However, information about seasonal variation and determinants of indoor PM concentrations could improve the design of interventions to decrease exposure by quantifying how PM would decrease with interventions aimed at changing fuel type or increasing ventilation (<xref rid="R21" ref-type="bibr">Ezzati and Kammen 2002</xref>).</p><p id="P6">For one year we measured PM concentrations each month in children&#x02019;s homes in a low-income community in urban Dhaka, Bangladesh monthly as part of an epidemiologic study to estimate the incidence and timing of acute lower respiratory infections in children &#x0003c;2 years of age. The objectives of this study were to describe seasonal patterns of indoor particulate matter concentrations and to estimate the association between these concentrations and potential sources of particulates in the home.</p></sec><sec sec-type="materials|methods" id="S2"><title>Materials and methods</title><sec id="S3"><title>Study population</title><p id="P7">Mirpur is a densely populated, low-income, urban community in Dhaka, Bangladesh (<xref rid="R23" ref-type="bibr">Haque et al. 2001</xref>). In January 2008, researchers at the International Centre for Diarrheal Diseases Research, Bangladesh (icddr,b) and the University of Virginia began enrolling a cohort of children in this community at birth to study the incidence and etiology of childhood gastrointestinal and respiratory infections and their associations with cognitive development. All pregnant women residing in the Mirpur study area between January 2008 and April 2009 were identified by community health workers employed by the study and asked to participate in the cohort. All children enrolled in this cohort between January 2008 and April 2009 were eligible to enroll in our sub-study to examine the relationship between indoor air pollution and respiratory disease. This paper presents findings on about the PM<sub>2.5</sub> concentrations in these children&#x02019;s homes.</p></sec><sec id="S4" sec-type="intro"><title>Measurement of household characteristics and indoor PM<sub>2.5</sub></title><p id="P8">Every household with a child participating in the sub-study was visited in April &#x02013; May 2009 and characteristics of the household were recorded using a structured questionnaire and observation form. Our study aimed to describe the determinants of indoor concentrations of particulate matter, so we attempted to measure all known sources of particulates for each household. Trained research assistants collected information from the child&#x02019;s mother about the number of people who lived in the house; the area of the dwelling&#x02019;s floor space; the number of windows and doors that opened to the outside; whether the cooking stove was inside or outside the living space; the kind of fuels burned in the home for cooking or other purposes; and whether or not any household members smoked tobacco in the house. During this survey in April &#x02013; May 2009, many household respondents told us that they had specialized stoves for cooking with natural gas or electricity, but these cleaner fuel sources were sometimes unavailable due to regular power outages or limited natural gas supply. If cleaner fuels were unavailable, some households burned biomass in traditional stoves as an alternative strategy. Therefore, we conducted a survey during March 2011 to collect data on all fuel types used by the household since May 2009 to capture this heterogeneity. Households that were not available to participate in the survey at the end of the study were categorized based on their baseline fuel use information.</p><p id="P9">From May 2009 through April 2010, concentrations of particulate matter of approximately 2.5 &#x003bc;m in diameter (PM<sub>2.5</sub>) were measured in the child&#x02019;s sleeping space for a 24 hour period once per month using PM monitors manufactured by the Berkeley Air Monitoring Group (<xref rid="R31" ref-type="bibr">Smith et al. 2007</xref>; <xref rid="R12" ref-type="bibr">Chowdhury et al. 2007</xref>; <xref rid="R19" ref-type="bibr">Edwards et al. 2006</xref>). The monitors were converted smoke detectors that used light scattering sensors to measure PM<sub>2.5</sub> approximate concentrations and these measurements were shown to correlate with gravimetric-based PM<sub>2.5</sub> samples (<xref rid="R12" ref-type="bibr">Chowdhury et al. 2007</xref>). The monitors were designed for use in highly polluted indoor environments and had a lower limit of detection of 50 &#x003bc;g/m<sup>3</sup> (<xref rid="R19" ref-type="bibr">Edwards et al. 2006</xref>).</p><p id="P10">Trained research assistants zeroed the monitors, placed them on the wall approximately two feet above the bed where the child enrolled in the birth cohort slept, and then retrieved the monitors from the home at least 24 hours later. The monitors logged the measured concentrations of PM<sub>2.5</sub> once per minute and these data were downloaded to a study computer. Twenty-four hours of measurements were retained for each day of sampling for the analysis, with one minute resolution (data collected at one minute intervals) for a total of 1440 measurements per each 24 hour period. Twenty-four hour observations with fewer than 1300 minute measurements recorded due to monitor or human error were excluded from the analysis. Readings at or below the limit of detection (50 &#x003bc;g/m<sup>3</sup>) were replaced using the beta substitution method for censored data arising from limits of detection (<xref rid="R22" ref-type="bibr">Ganser and Hewett, 2010</xref>).</p></sec><sec id="S5"><title>Statistical analyses</title><p id="P11">We described study households in terms of whether their cooking stove was inside or outside, the type of fuel used for cooking at baseline, tobacco smoking inside the home, and the number of doors and windows that opened to the outside. We created fuel use categories to capture heterogeneity in fuel use based on the survey at the end of the study and classified households as either using clean fuels only during the study period, which included both natural gas and electricity, using biomass fuels only, or using primarily clean, but occasionally biomass fuels. Households with missing data on fuel use from the survey at the end of the study were classified as burning biomass only if they reported at baseline that their primary fuel source was biomass. All others with missing data were classified as using primarily clean fuels with some biomass.</p><p id="P12">The PM<sub>2.5</sub> concentrations were summarized for each 24-hour observation period using three exposure metrics. Time-weighted average (arithmetic mean) PM<sub>2.5</sub> concentrations were calculated to represent daily exposures and the 90<sup>th</sup> percentile PM<sub>2.5</sub> concentration was used as an indicator of peak daily exposures in the home. In addition, we calculated the number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> for each 24 hour observation period (daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup>). The threshold of 100 &#x003bc;g/m<sup>3</sup> does not represent a concentration associated with poorer health outcomes but was chosen for exploratory analyses because it represented twice the limit of detection of the monitors and four times the World Health Organization guidelines for indoor air quality (25 &#x003bc;g/m<sup>3</sup> daily mean) (<xref rid="R3" ref-type="bibr">Anon. 2006</xref>).</p><p id="P13">The number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> were plotted by measurement date and locally weighted scatterplot smoothing (LOWESS) curves (<xref rid="R14" ref-type="bibr">Cleveland and Devlin 1988</xref>) were estimated to compare seasonal variation in PM<sub>2.5</sub> concentrations by fuel type. We defined four seasons: winter (December &#x02013; February), spring (March &#x02013; May), monsoon (June &#x02013; September), and post-monsoon (October &#x02013; November) (<xref rid="R27" ref-type="bibr">Salam et al. 2003</xref>). To account for the clustered nature of observations within each household, generalized estimating equations were fitted to estimate the population-averaged associations between fuel use, stove location, the number of windows and doors, indoor tobacco smoking, and season with time-weighted average PM<sub>2.5</sub> concentrations, 90<sup>th</sup> percentile PM<sub>2.5</sub> concentrations, and daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup> (<xref rid="R24" ref-type="bibr">Liang and Zeger, 1986</xref>). We defined binary variables for each season and the season with the lowest values defined the baseline. An additional analysis objective was to estimate the subject-specific associations with covariates as well as the proportion of the variation in PM<sub>2.5</sub> concentrations that was explained by differences between households. To accomplish this, a random effects model, including a random intercept for each household, was fitted for each of the exposure metrics in Stata 10 using <italic>xtmixed</italic> with an unstructured correlation matrix. The intraclass correlation coefficients were calculated using <italic>xtmrho</italic> (Stata Corp, TX).</p></sec><sec id="S6"><title>Human subject considerations</title><p id="P14">Prior to enrollment, all mothers provided either a signature or a thumb print indicating their informed consent for participation. Institutional Review Boards at the following institutions reviewed and approved the protocol: icddr,b, Dhaka, Bangladesh University of Virginia, Charlottesville, VA; US Centers for Disease Control and Prevention, Atlanta, GA; and Johns Hopkins Bloomberg School of Public Health, Baltimore, MD.</p></sec></sec><sec sec-type="results" id="S7"><title>Results</title><p id="P15">Two hundred and sixty-two households were enrolled in the primary cohort since January 2008 and still enrolled when this study began in May 2009. All of these households in the birth cohort study agreed to participate in the study on indoor particulate matter. Two hundred and fifty-eight households (98%) had complete baseline information collected and were included in the analysis. Of those 258, 213 (83%) completed the survey at the end of the study on types of cooking fuels used since May 2009. Forty-two percent of households exclusively used clean fuels, such as natural gas or electricity, for cooking and 16% used primarily biomass, including wood, jute, bamboo, and paper. Fifty-two percent used a combination of both clean and biomass fuels for cooking during the study period. Households had a median of 5 residents living in a median of 9.6 meters<sup>2</sup> of floor space, and 28% reported that at least one household member smoked tobacco indoors (<xref rid="T1" ref-type="table">Table 1</xref>).</p><p id="P16">Fifteen (0.5%) 24-hour measurements were excluded from the analysis because fewer than 1300 minutes were recorded. Overall, 49% of all PM<sub>2.5</sub> measurements were at or below the limit of detection (50 &#x003bc;g/m<sup>3</sup>) (<xref rid="T2" ref-type="table">Table 2</xref>). The mean time-weighted average PM<sub>2.5</sub> concentrations were 190 &#x003bc;g/m<sup>3</sup> (95% confidence interval [95% CI] 170&#x02013;210), mean 90<sup>th</sup> percentile values were 438 &#x003bc;g/m<sup>3</sup> (387&#x02013;489), and mean number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> each day (daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup>) were 5.7 (5.5&#x02013;5.9) (<xref rid="T2" ref-type="table">Table 2</xref>). All three exposure metrics were higher in winter compared to other seasons, higher in households that used only biomass fuel compared to other households, and were higher in homes with &#x02264;1 external window or door compared to homes with &#x02265;2 (the median number among study households) (<xref rid="T2" ref-type="table">Table 2</xref>). There were no significant differences in PM<sub>2.5</sub> concentrations for households that cooked inside the home compared with outside (<xref rid="T2" ref-type="table">Table 2</xref>). There were no significant differences between PM<sub>2.5</sub> concentrations in each season by location of cooking stove (data not shown).</p><p id="P17">For each 24-hour period, the number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> varied from 0 to 24; the lowest values occurred during the humid and rainy monsoon months (July &#x02013; September) and the highest during the cooler, dry winter season (December &#x02013; February) (<xref rid="R27" ref-type="bibr">Salam et al. 2003</xref>) (<xref rid="F1" ref-type="fig">Figure 1</xref>). Households burning only biomass had more hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> compared to other homes throughout the year. The number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> during winter in homes burning only clean fuels were similar to the number in homes burning only biomass in the spring and monsoon seasons (<xref rid="F1" ref-type="fig">Figure 1</xref>).</p><p id="P18">Primarily burning biomass for cooking was independently associated with a 75 &#x003bc;g/m<sup>3</sup> (95% CI 6 &#x02013; 124) increase in time-weighted PM<sub>2.5</sub> concentrations in the marginal model. Each additional external windows and/or doors was associated with a 22 &#x003bc;g/m<sup>3</sup> decrease (95% CI &#x02212;43 &#x02013; &#x02212;0.2) in time-weighted PM<sub>2.5</sub> concentrations, and winter season was associated with a 225 &#x003bc;g/m<sup>3</sup> increase (95% CI 163 &#x02013; 287) (<xref rid="T3" ref-type="table">Table 3</xref>). Each additional external window or door was associated with a decrease (&#x02212;56 &#x003bc;g/m<sup>3</sup>, 95% CI &#x02212;110 &#x02013; &#x02212;1) in 90<sup>th</sup> percentile PM<sub>2.5</sub> concentrations and winter season was associated with an increase (537 &#x003bc;g/m<sup>3</sup>, 95% CI 377 &#x02013; 696). All predictors except stove location were associated with the number of hours each day that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> (daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup>), including exposure to indoor tobacco smoking. Similar to the other PM<sub>2.5</sub> concentration metrics, winter season was the most important predictor of the number of hours that PM<sub>2.5</sub> concentrations exceeded100 &#x003bc;g/m<sup>3</sup> (5.6 hours, 95% CI 5.2 &#x02013; 6.0) (<xref rid="T3" ref-type="table">Table 3</xref>). Subject specific associations from the random intercept model were consistent with the population-averaged associations from the marginal model (<xref rid="T4" ref-type="table">Table 4</xref>).</p><p id="P19">The intracalss correlation coefficient was 0.02 for the time-weighted average PM<sub>2.5</sub> concentrations, 0.02 for the 90<sup>th</sup> percentile values, and 0.16 for the number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup>, representing the proportion of variation in those measurements that was attributable to differences between rather than within each household.</p></sec><sec sec-type="discussion" id="S8"><title>Discussion</title><p id="P20">Time-weighted average PM<sub>2.5</sub> concentrations in our study homes were approximately 7 times higher than the daily mean PM<sub>2.5</sub> guidelines recommended by the World Health Organization (<xref rid="R3" ref-type="bibr">Anon. 2006</xref>). Based on the random intercept model estimates, changing a household cookstove from biomass only to exclusive use of clean fuels would be expected to reduce the time-weighted average daily PM<sub>2.5</sub> concentrations by 65 &#x003bc;g/m<sup>3</sup> (95% CI 4&#x02013;125). Each external door and window was associated with a significant decrease in PM<sub>2.5</sub>, but the effect of doors and windows on PM<sub>2.5</sub> was less important than the effect of biomass use. World Health Organization guidelines on indoor PM<sub>2.5</sub> concentrations recommended interim targets for reducing daily mean PM concentrations in settings where achieving the standard of 25 &#x003bc;g/m<sup>3</sup> is difficult (<xref rid="R3" ref-type="bibr">Anon. 2006</xref>). Our results suggest that the first interim target of 75 &#x003bc;g/m<sup>3</sup> (<xref rid="R3" ref-type="bibr">Anon. 2006</xref>) may be achievable in our study community if biomass stoves are replaced by cleaner burning fuels.</p><p id="P21">Indoor tobacco smoking has been repeatedly associated with increased PM indoors in high income countries (<xref rid="R32" ref-type="bibr">Van Deusen et al. 2009</xref>; <xref rid="R25" ref-type="bibr">Monn et al. 1997</xref>), and one study in Bangladesh found that children who had a family member who smoked in the home were at increased risk for acute respiratory infection (<xref rid="R28" ref-type="bibr">Rahman and Rahman 1997</xref>). Smoking tobacco indoors was associated with a 0.6 hour increase (95% CI 0.1 &#x02013; 1.1) in the number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> in our study. Tobacco was smoked indoors in 28% of our study households and these results suggest efforts to prevent indoor tobacco smoking may meaningfully reduce indoor exposures to PM<sub>2.5</sub> in this community.</p><p id="P22">Interventions to reduce indoor exposures to PM in low-income countries have focused on promoting use of cleaner burning fuels, like natural gas or electricity, or use of more efficient stoves (<xref rid="R30" ref-type="bibr">Smith 2002</xref>; <xref rid="R2" ref-type="bibr">Albalak et al. 2001</xref>; <xref rid="R11" ref-type="bibr">Bruce et al. 2000</xref>). Burning clean fuels was associated with lower time-weighted PM<sub>2.5</sub> concentrations in our study, but even homes that burned clean fuels for cooking had mean PM<sub>2.5</sub> concentrations approximately 6 times higher than the World Health Organization guidelines (<xref rid="R3" ref-type="bibr">Anon. 2006</xref>). A small study from Bangladesh showed that homes that cooked with natural gas experienced indoor PM concentrations that mirrored ambient concentrations over a 24-hour period (<xref rid="R16" ref-type="bibr">Dasgupta et al. 2006a</xref>). Another study from a crowded community in Bangladesh, similar to our study site, reported that the ambient air was highly polluted from numerous sources and this pollution likely influenced indoor air quality (<xref rid="R13" ref-type="bibr">Chowdhury et al. 2012</xref>). Penetration of ambient pollution indoors has been established in other settings (<xref rid="R1" ref-type="bibr">Abt et al. 2000</xref>; <xref rid="R29" ref-type="bibr">Sapkota et al. 2005</xref>). These findings suggest that indoor PM exposures in our urban community are partially influenced by ambient PM sources.</p><p id="P23">The most important predictor of indoor PM<sub>2.5</sub> concentrations in our study was season, but the explanation for this finding is unclear. There could be a number of explanations for the large increases in PM<sub>2.5</sub> concentrations we observed during winter. One study from rural Bangladesh showed that the ability of air to move through the house was associated with decreased concentrations of particulate matter (<xref rid="R7" ref-type="bibr">Begum et al. 2009</xref>). As temperatures decrease in the winter months, windows and doors may be closed more often, reducing ventilation and thus trapping PM<sub>2.5</sub> inside. In addition, there may have been increases in biomass burning in homes during winter that were not captured in our data collection. In our analyses, we did not repeat measurements of ventilation or fuel use in multiple seasons. However, 67% of households did not cook inside the home, the location of the cooking stove was not associated with PM<sub>2.5</sub> concentrations, and households that cooked outside experienced the same seasonal variation in PM<sub>2.5</sub> concentrations as households that cooked inside. This suggests that even if there were differences in what was burned in the stove during winter, these differences are unlikely to account for the large increases in PM<sub>2.5</sub> we observed.</p><p id="P24">Another plausible explanation for the increase during winter is the contribution of ambient PM<sub>2.5</sub> sources to indoor air in this community. Ambient PM concentrations in Dhaka show a strong seasonal pattern with peaks in the winter, similar to the winter peaks observed in this study (<xref rid="R8" ref-type="bibr">Begum et al. 2011</xref>). Ambient PM concentrations in Dhaka may be higher during the winter due to meteorological conditions, including temperature inversions and relatively little rainfall (<xref rid="R8" ref-type="bibr">Begum et al. 2011</xref>). However, there may also be seasonal differences in ambient sources of PM which contribute to these seasonal differences. Analyses of the components of ambient air pollution in Dhaka in the winter suggest that 30% of fine PM is attributable to brick kiln fires (<xref rid="R8" ref-type="bibr">Begum et al. 2011</xref>). More than 500 brick kilns burn continuously during the dry season, from October to May, on the northern side of Dhaka (Croitoru and Sarraf, 2012). More research is needed to better understand the possible role of ambient PM in determining indoor PM exposures in urban Bangladesh.</p><p id="P25">Measured PM<sub>2.5</sub> concentrations were highly variable within households over time, indicating that one 24-hour measurement at one time point is unlikely to provide a reliable estimate of exposure for epidemiologic studies. The number of hours that the PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> were less variable and not affected by the monitors&#x02019; limit of detection, and may be a useful alternative metric for use to describe exposure-disease relationships.</p><p id="P26">Our findings are limited because we only measured fuel use at baseline and the end of the study and these may have changed over the course of the study period and may have changed by season. However, we attempted to capture variability in fuel use during the study period and defined a distinct category of households that used primarily cleaner fuels with some biomass burning during shortages of other fuels. Our results show that these homes had slightly higher concentrations of PM<sub>2.5</sub> than homes that used exclusively cleaner fuels, but much lower levels than homes that used exclusively biomass, indicating that our household fuel use classification system was valid. We measured the number of doors and windows that opened to the outside as a proxy measurement for ventilation in the home. However, the placement of windows or doors, and the timing of when they were open would likely change their effectiveness at reducing PM<sub>2.5</sub> concentrations and those data were not included in our model.</p></sec><sec sec-type="conclusions" id="S9"><title>Conclusions</title><p id="P27">Indoor daily PM<sub>2.5</sub> concentrations in this low-income neighborhood are more than 7 times greater than those suggested by the World Health Organization guidelines for air quality (<xref rid="R3" ref-type="bibr">Anon. 2006</xref>). Interventions to eliminate cooking with biomass could significantly reduce exposures to PM<sub>2.5</sub> in these homes. Interventions to increase ventilation and prevent indoor tobacco smoking may also meaningfully reduce exposures. The most important predictor of indoor PM<sub>2.5</sub> concentrations was season. Large increases in PM<sub>2.5</sub> concentrations during winter remain unexplained. Studies to investigate additional sources of indoor PM<sub>2.5</sub> during winter, including ambient PM<sub>2.5</sub>, are needed.</p></sec></body><back><ack id="S11"><p><bold>Acknowledgements and funding:</bold> This study was funded by the United States Centers for Disease Control and Prevention (CDC), grant number U01/CI000628-02 and the National Institutes of Health, USA (NIH), grant number 5R01 AI043596. ICDDR,B acknowledges with gratitude the commitment of CDC and NIH to its research efforts. The authors wish to thank the children and their families for their participation in this cohort. We appreciated the statistical assistance of Jaynal Abedin and Yushuf Sharker.</p></ack><fn-group><fn id="FN2" fn-type="conflict"><p><bold>Competing financial interests:</bold> The authors declare that we have no competing financial interests.</p></fn><fn id="FN3"><p content-type="publisher-disclaimer">This is a PDF file of an unedited manuscript that has been accepted for publication. As a service to our customers we are providing this early version of the manuscript. The manuscript will undergo copyediting, typesetting, and review of the resulting proof before it is published in its final citable form. Please note that during the production process errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.</p></fn></fn-group><ref-list><ref id="R1"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Abt</surname><given-names>E</given-names></name><name><surname>Suh</surname><given-names>HH</given-names></name><name><surname>Catalano</surname><given-names>P</given-names></name><name><surname>Koutrakis</surname><given-names>P</given-names></name></person-group><year>2000</year><article-title>Contribution of outdoor and indoor particle sources to indoor concentrations</article-title><source>Environmental Science and Technology</source><volume>34</volume><issue>17</issue><fpage>3579</fpage><lpage> 3587</lpage></element-citation></ref><ref id="R2"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Albalak</surname><given-names>R</given-names></name><name><surname>Bruce</surname><given-names>N</given-names></name><name><surname>McCracken</surname><given-names>JP</given-names></name><name><surname>Smith</surname><given-names>KR</given-names></name><name><surname>De Gallardo</surname><given-names>T</given-names></name></person-group><year>2001</year><article-title>Indoor respirable particulate matter concentrations from an open fire, improved cookstove, and LPG/open fire combination in a rural Guatemalan community</article-title><source>Environ Sci Technol</source><volume>35</volume><issue>13</issue><fpage>2650</fpage><lpage>2655</lpage><pub-id pub-id-type="pmid">11452588</pub-id></element-citation></ref><ref id="R3"><element-citation publication-type="book"><person-group person-group-type="author"><anonymous/></person-group><year>2006</year><source>WHO Air quality guidelines for particulate matter, ozone, nitrogen dioxide and sulfur dioxide: Global update 2005</source><publisher-name>World Health Organization</publisher-name></element-citation></ref><ref id="R4"><element-citation publication-type="book"><person-group person-group-type="author"><anonymous/></person-group><year>2007</year><source>Indoor Air Pollution: National Burden of Disease Estimates</source><publisher-loc>Geneva</publisher-loc><publisher-name>World Health Organization</publisher-name></element-citation></ref><ref id="R5"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Baqui</surname><given-names>AH</given-names></name><name><surname>Sabir</surname><given-names>AA</given-names></name><name><surname>Begum</surname><given-names>N</given-names></name><name><surname>Arifeen</surname><given-names>SE</given-names></name><name><surname>Mitra</surname><given-names>SN</given-names></name><name><surname>Black</surname><given-names>RE</given-names></name></person-group><year>2001</year><article-title>Causes of childhood deaths in Bangladesh: an update</article-title><source>Acta Paediatr</source><volume>90</volume><issue>6</issue><fpage>682</fpage><lpage>690</lpage><pub-id pub-id-type="pmid">11440104</pub-id></element-citation></ref><ref id="R6"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bautista</surname><given-names>LE</given-names></name><name><surname>Correa</surname><given-names>A</given-names></name><name><surname>Baumgartner</surname><given-names>J</given-names></name><name><surname>Breysse</surname><given-names>P</given-names></name><name><surname>Matanoski</surname><given-names>GM</given-names></name></person-group><year>2009</year><article-title>Indoor charcoal smoke and acute respiratory infections in young children in the Dominican Republic</article-title><source>Am J Epidemiol</source><volume>169</volume><issue>5</issue><fpage>572</fpage><lpage>580</lpage><pub-id pub-id-type="pmid">19126589</pub-id></element-citation></ref><ref id="R7"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Begum</surname><given-names>BA</given-names></name><name><surname>Paul</surname><given-names>SK</given-names></name><name><surname>Hossain</surname><given-names>MD</given-names></name><name><surname>Biswas</surname><given-names>SK</given-names></name><name><surname>Hopke</surname><given-names>PK</given-names></name></person-group><year>2009</year><article-title>Indoor air pollution from particulate matter emissions in different households in rural areas of Bangladesh</article-title><source>Building Environ</source><volume>44</volume><issue>5</issue><fpage>898</fpage><lpage>903</lpage></element-citation></ref><ref id="R8"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Begum</surname><given-names>BA</given-names></name><name><surname>Biswas</surname><given-names>SK</given-names></name><name><surname>Hopke</surname><given-names>PK</given-names></name></person-group><year>2011</year><article-title>Key issues in controlling air pollutants in Dhaka, Bangladesh</article-title><source>Atmospheric Environ</source><volume>45</volume><issue>40</issue><fpage>7705</fpage><lpage>7713</lpage></element-citation></ref><ref id="R9"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Black</surname><given-names>RE</given-names></name><name><surname>Morris</surname><given-names>SS</given-names></name><name><surname>Bryce</surname><given-names>J</given-names></name></person-group><year>2003</year><article-title>Where and why are 10 million children dying every year?</article-title><source>Lancet</source><volume>361</volume><issue>9376</issue><fpage>2226</fpage><lpage>2234</lpage><pub-id pub-id-type="pmid">12842379</pub-id></element-citation></ref><ref id="R10"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Black</surname><given-names>RE</given-names></name><name><surname>Cousens</surname><given-names>S</given-names></name><name><surname>Johnson</surname><given-names>HL</given-names></name><name><surname>Lawn</surname><given-names>JE</given-names></name><name><surname>Rudan</surname><given-names>I</given-names></name><name><surname>Bassani</surname><given-names>DG</given-names></name><etal/></person-group><year>2010</year><article-title>Global, regional, and national causes of child mortality in 2008: a systematic analysis</article-title><source>Lancet</source><volume>375</volume><issue>9730</issue><fpage>1969</fpage><lpage>1987</lpage><pub-id pub-id-type="pmid">20466419</pub-id></element-citation></ref><ref id="R11"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bruce</surname><given-names>N</given-names></name><name><surname>Perez-Padilla</surname><given-names>R</given-names></name><name><surname>Albalak</surname><given-names>R</given-names></name></person-group><year>2000</year><article-title>Indoor air pollution in developing countries: a major environmental and public health challenge</article-title><source>Bull World Health Organ</source><volume>78</volume><issue>9</issue><fpage>1078</fpage><lpage>1092</lpage><pub-id pub-id-type="pmid">11019457</pub-id></element-citation></ref><ref id="R12"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chowdhury</surname><given-names>Z</given-names></name><name><surname>Edwards</surname><given-names>RD</given-names></name><name><surname>Johnson</surname><given-names>M</given-names></name><name><surname>Naumoff Shields</surname><given-names>K</given-names></name><name><surname>Allen</surname><given-names>T</given-names></name><name><surname>Canuz</surname><given-names>E</given-names></name><etal/></person-group><year>2007</year><article-title>An inexpensive light-scattering particle monitor: field validation</article-title><source>J Environ Monit</source><volume>9</volume><issue>10</issue><fpage>1099</fpage><lpage>1106</lpage><pub-id pub-id-type="pmid">17909644</pub-id></element-citation></ref><ref id="R13"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chowdhury</surname><given-names>Z</given-names></name><name><surname>Le</surname><given-names>LT</given-names></name><name><surname>Masud</surname><given-names>AA</given-names></name><name><surname>Change</surname><given-names>KC</given-names></name><name><surname>Alauddin</surname><given-names>M</given-names></name><name><surname>Hossain</surname><given-names>M</given-names></name><name><surname>Zakarias</surname><given-names>ABM</given-names></name><name><surname>Hopke</surname><given-names>PK</given-names></name></person-group><year>2012</year><article-title>Quantification of indoor air pollution from using cookstoves and estimation of its health effects on adult women in northwestern Bangladesh</article-title><source>Aerosol Air Qual Res</source><volume>12</volume><fpage>463</fpage><lpage>475</lpage></element-citation></ref><ref id="R14"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cleveland</surname><given-names>WS</given-names></name><name><surname>Devlin</surname><given-names>SJ</given-names></name></person-group><year>1988</year><article-title>Locally weighted regression: An approach to regression analysis by local fitting</article-title><source>Journal of the American Statistical Association</source><volume>83</volume><issue>403</issue><fpage>596</fpage><lpage> 610</lpage></element-citation></ref><ref id="R15"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Croitoru</surname><given-names>L</given-names></name><name><surname>Sarraf</surname><given-names>M</given-names></name></person-group><article-title>Benefits and costs of the informal sector: The case of brick kilns in Bangladesh</article-title><source>J Environ Protection</source><volume>3</volume><fpage>476</fpage><lpage>484</lpage></element-citation></ref><ref id="R16"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dasgupta</surname><given-names>S</given-names></name><name><surname>Huq</surname><given-names>M</given-names></name><name><surname>Khaliquzzaman</surname><given-names>M</given-names></name><name><surname>Pandey</surname><given-names>K</given-names></name><name><surname>Wheeler</surname><given-names>D</given-names></name></person-group><year>2006a</year><article-title>Indoor air quality for poor families: new evidence from Bangladesh</article-title><source>Indoor Air</source><volume>16</volume><issue>6</issue><fpage>426</fpage><lpage>444</lpage><pub-id pub-id-type="pmid">17100664</pub-id></element-citation></ref><ref id="R17"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dasgupta</surname><given-names>S</given-names></name><name><surname>Huq</surname><given-names>M</given-names></name><name><surname>Khaliquzzaman</surname><given-names>M</given-names></name><name><surname>Pandey</surname><given-names>K</given-names></name><name><surname>Wheeler</surname><given-names>D</given-names></name></person-group><year>2006b</year><article-title>Who suffers from indoor air pollution? Evidence from Bangladesh</article-title><source>Health Policy Plan</source><volume>21</volume><issue>6</issue><fpage>444</fpage><lpage>458</lpage><pub-id pub-id-type="pmid">17030552</pub-id></element-citation></ref><ref id="R18"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dherani</surname><given-names>M</given-names></name><name><surname>Pope</surname><given-names>D</given-names></name><name><surname>Mascarenhas</surname><given-names>M</given-names></name><name><surname>Smith</surname><given-names>KR</given-names></name><name><surname>Weber</surname><given-names>M</given-names></name><name><surname>Bruce</surname><given-names>N</given-names></name></person-group><year>2008</year><article-title>Indoor air pollution from unprocessed solid fuel use and pneumonia risk in children aged under five years: a systematic review and meta-analysis</article-title><source>Bull World Health Organ</source><volume>86</volume><issue>5</issue><fpage>390</fpage><lpage>398C</lpage><pub-id pub-id-type="pmid">18545742</pub-id></element-citation></ref><ref id="R19"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Edwards</surname><given-names>R</given-names></name><name><surname>Smith</surname><given-names>KR</given-names></name><name><surname>Kirby</surname><given-names>B</given-names></name><name><surname>Allen</surname><given-names>T</given-names></name><name><surname>Litton</surname><given-names>CD</given-names></name><name><surname>Hering</surname><given-names>S</given-names></name></person-group><year>2006</year><article-title>An inexpensive dual-chamber particle monitor: laboratory characterization</article-title><source>J Air Waste Manag Assoc</source><volume>56</volume><issue>6</issue><fpage>789</fpage><lpage>799</lpage><pub-id pub-id-type="pmid">16805403</pub-id></element-citation></ref><ref id="R20"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ezzati</surname><given-names>M</given-names></name><name><surname>Kammen</surname><given-names>D</given-names></name></person-group><year>2001</year><article-title>Indoor air pollution from biomass combustion and acute respiratory infections in Kenya: an exposure-response study</article-title><source>Lancet</source><volume>358</volume><issue>9282</issue><fpage>619</fpage><lpage>624</lpage><pub-id pub-id-type="pmid">11530148</pub-id></element-citation></ref><ref id="R21"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ezzati</surname><given-names>M</given-names></name><name><surname>Kammen</surname><given-names>DM</given-names></name></person-group><year>2002</year><article-title>The health impacts of exposure to indoor air pollution from solid fuels in developing countries: knowledge, gaps, and data needs</article-title><source>Environ Health Perspect</source><volume>110</volume><issue>11</issue><fpage>1057</fpage><lpage>1068</lpage><pub-id pub-id-type="pmid">12417475</pub-id></element-citation></ref><ref id="R22"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ganser</surname><given-names>GH</given-names></name><name><surname>Hewett</surname><given-names>P</given-names></name></person-group><year>2010</year><article-title>An accurate substitution method for analyzing censored data</article-title><source>J Occup Environ Hyg</source><volume>7</volume><issue>4</issue><fpage>233</fpage><lpage>244</lpage><pub-id pub-id-type="pmid">20169489</pub-id></element-citation></ref><ref id="R23"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Haque</surname><given-names>R</given-names></name><name><surname>Ali</surname><given-names>IM</given-names></name><name><surname>Sack</surname><given-names>RB</given-names></name><name><surname>Farr</surname><given-names>BM</given-names></name><name><surname>Ramakrishnan</surname><given-names>G</given-names></name><name><surname>Petri</surname><given-names>WA</given-names><suffix>Jr</suffix></name></person-group><year>2001</year><article-title>Amebiasis and mucosal IgA antibody against the Entamoeba histolytica adherence lectin in Bangladeshi children</article-title><source>J Infect Dis</source><volume>183</volume><issue>12</issue><fpage>1787</fpage><lpage>1793</lpage><pub-id pub-id-type="pmid">11372032</pub-id></element-citation></ref><ref id="R24"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Liang</surname><given-names>KY</given-names></name><name><surname>Zeger</surname><given-names>SL</given-names></name></person-group><year>1986</year><article-title>Longitudinal analysis using generalized linear models</article-title><source>Biometrika</source><volume>73</volume><issue>1</issue><fpage>13</fpage><lpage>22</lpage></element-citation></ref><ref id="R25"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Monn</surname><given-names>C</given-names></name><name><surname>Fuchs</surname><given-names>A</given-names></name><name><surname>Hogger</surname><given-names>D</given-names></name><name><surname>Junker</surname><given-names>M</given-names></name><name><surname>Kogelschatz</surname><given-names>D</given-names></name><name><surname>Roth</surname><given-names>N</given-names></name><etal/></person-group><year>1997</year><article-title>Particulate matter less than 10 microns (PM10) and fine particles less than 2.5 microns (PM2.5): relationships between indoor, outdoor and personal concentrations</article-title><source>Sci Total Environ</source><volume>208</volume><issue>1&#x02013;2</issue><fpage>15</fpage><lpage>21</lpage><pub-id pub-id-type="pmid">9496645</pub-id></element-citation></ref><ref id="R26"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Naeher</surname><given-names>LP</given-names></name><name><surname>Brauer</surname><given-names>M</given-names></name><name><surname>Lipsett</surname><given-names>M</given-names></name><name><surname>Zelikoff</surname><given-names>JT</given-names></name><name><surname>Simpson</surname><given-names>CD</given-names></name><name><surname>Koenig</surname><given-names>JQ</given-names></name><etal/></person-group><year>2007</year><article-title>Woodsmoke health effects: a review</article-title><source>Inhal Toxicol</source><volume>19</volume><issue>1</issue><fpage>67</fpage><lpage>106</lpage><pub-id pub-id-type="pmid">17127644</pub-id></element-citation></ref><ref id="R27"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Salam</surname><given-names>A</given-names></name><name><surname>Bauer</surname><given-names>H</given-names></name><name><surname>Kassin</surname><given-names>K</given-names></name><name><surname>Ullah</surname><given-names>SM</given-names></name><name><surname>Puxbaum</surname><given-names>H</given-names></name></person-group><year>2003</year><article-title>Aerosol chemical characteristics of a mega-city in Southeast Asia (Dhaka, Bangladesh)</article-title><source>Atmospheric Environment</source><volume>37</volume><fpage>2517</fpage><lpage> 2528</lpage></element-citation></ref><ref id="R28"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rahman</surname><given-names>MM</given-names></name><name><surname>Rahman</surname><given-names>AM</given-names></name></person-group><year>1997</year><article-title>Prevalence of acute respiratory tract infection and its risk factors in under five children</article-title><source>Bangladesh Med Res Counc Bull</source><volume>23</volume><issue>2</issue><fpage>47</fpage><lpage>50</lpage><pub-id pub-id-type="pmid">9465435</pub-id></element-citation></ref><ref id="R29"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sapkota</surname><given-names>A</given-names></name><name><surname>Symons</surname><given-names>JM</given-names></name><name><surname>Kleissl</surname><given-names>J</given-names></name><name><surname>Wang</surname><given-names>L</given-names></name><name><surname>Parlange</surname><given-names>MB</given-names></name><name><surname>Ondov</surname><given-names>J</given-names></name><etal/></person-group><year>2005</year><article-title>Impact of the 2002 Canadian forest fires on particulate matter air quality in Baltimore city</article-title><source>Environ Sci Technol</source><volume>39</volume><issue>1</issue><fpage>24</fpage><lpage>32</lpage><pub-id pub-id-type="pmid">15667071</pub-id></element-citation></ref><ref id="R30"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Smith</surname><given-names>KR</given-names></name></person-group><year>2002</year><article-title>Indoor air pollution in developing countries: recommendations for research</article-title><source>Indoor Air</source><volume>12</volume><issue>3</issue><fpage>198</fpage><lpage>207</lpage><pub-id pub-id-type="pmid">12244750</pub-id></element-citation></ref><ref id="R31"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Smith</surname><given-names>KR</given-names></name><name><surname>Dutta</surname><given-names>K</given-names></name><name><surname>Chengappa</surname><given-names>C</given-names></name><name><surname>Gusain</surname><given-names>PPS</given-names></name><name><surname>Masera</surname><given-names>O</given-names></name><name><surname>Berrueta</surname><given-names>V</given-names></name><etal/></person-group><year>2007</year><article-title>Monitoring and evaluation of improved biomass cookstove programs for indoor air quality and stove performance: conclusions from the Household Energy and Health project</article-title><source>Energy for Sustainable Development</source><volume>9</volume><issue>2</issue><fpage>5</fpage><lpage>18</lpage></element-citation></ref><ref id="R32"><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Van Deusen</surname><given-names>A</given-names></name><name><surname>Hyland</surname><given-names>A</given-names></name><name><surname>Travers</surname><given-names>MJ</given-names></name><name><surname>Wang</surname><given-names>C</given-names></name><name><surname>Higbee</surname><given-names>C</given-names></name><name><surname>King</surname><given-names>BA</given-names></name><etal/></person-group><year>2009</year><article-title>Secondhand smoke and particulate matter exposure in the home</article-title><source>Nicotine Tob Res</source><volume>11</volume><issue>6</issue><fpage>635</fpage><lpage>641</lpage><pub-id pub-id-type="pmid">19351784</pub-id></element-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Figure 1</label><caption><p>Number of hours that PM<sub>2.5</sub> concentrations exceeded 100 &#x003bc;g/m<sup>3</sup> for all observations with locally weighted scatterplot smoothing (LOWESS) curves by the type of fuel used for cooking, May 2009 &#x02013; April 2010</p></caption><graphic xlink:href="nihms442038f1"/></fig><table-wrap id="T1" position="float" orientation="portrait"><label>Table 1</label><caption><p>Characteristics of study homes in a low-income, urban neighborhood in Mirpur, Dhaka, 2009 &#x02013; 2010 (N=258)</p></caption><table frame="hsides" rules="none"><thead><tr><th valign="top" align="left" rowspan="1" colspan="1">Household characteristics</th><th valign="top" align="center" rowspan="1" colspan="1">N (%)</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Tobacco smoked inside home</td><td align="center" valign="top" rowspan="1" colspan="1">73 (28)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Cooking stove located inside dwelling</td><td align="center" valign="top" rowspan="1" colspan="1">85 (33)</td></tr><tr><td colspan="2" align="left" valign="top" rowspan="1">&#x02003;Type of fuel primarily used for cooking</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Natural gas</td><td align="center" valign="top" rowspan="1" colspan="1">164 (64)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Electricity</td><td align="center" valign="top" rowspan="1" colspan="1">51 (20)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Biomass (wood, jute, bamboo, paper)</td><td align="center" valign="top" rowspan="1" colspan="1">40 (16)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Kerosene</td><td align="center" valign="top" rowspan="1" colspan="1">3 (1)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Regularly burns kerosene indoors for any purpose</td><td align="center" valign="top" rowspan="1" colspan="1">119 (46)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Fuel use category</td><td align="center" valign="top" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Only uses clean fuels</td><td align="center" valign="top" rowspan="1" colspan="1">107 (42)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Uses both clean and biomass fuels</td><td align="center" valign="top" rowspan="1" colspan="1">135 (52)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;&#x02003;Only uses biomass fuels</td><td align="center" valign="top" rowspan="1" colspan="1">16 (6)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1">(median, interquartile range)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Number of external doors and windows in sleeping space</td><td align="center" valign="top" rowspan="1" colspan="1">2 (1 &#x02013; 3)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Number of people in household</td><td align="center" valign="top" rowspan="1" colspan="1">5 (4 &#x02013; 6)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Floor of living space in meters<sup>2</sup></td><td align="center" valign="top" rowspan="1" colspan="1">9.6 (7.8 &#x02013; 11.3)</td></tr></tbody></table></table-wrap><table-wrap id="T2" position="float" orientation="portrait"><label>Table 2</label><caption><p>Time-weighted average particulate matter (PM<sub>2..5</sub>) concentrations, 90<sup>th</sup> percentiles, and daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup> by fuel type, season, location of cooking stove, and number of external doors and windows</p></caption><table frame="hsides" rules="groups"><thead><tr><th valign="top" align="left" rowspan="1" colspan="1"/><th valign="top" align="center" rowspan="1" colspan="1">Percent of minute measurements at or below limit of detection</th><th valign="top" align="center" rowspan="1" colspan="1">Time- weighted average in &#x003bc;g/m<sup>3</sup> (95% CI)</th><th valign="top" align="center" rowspan="1" colspan="1">90<sup>th</sup> percentile in &#x003bc;g/m<sup>3</sup> (95% CI)</th><th valign="top" align="center" rowspan="1" colspan="1">Daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup> (95% CI)</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Overall</td><td align="center" valign="top" rowspan="1" colspan="1">49</td><td align="center" valign="top" rowspan="1" colspan="1">190 (170 &#x02013; 210)</td><td align="center" valign="top" rowspan="1" colspan="1">438 (387 &#x02013; 489)</td><td align="center" valign="top" rowspan="1" colspan="1">5.7 (5.5 &#x02013; 5.9)</td></tr><tr><td colspan="5" align="left" valign="top" rowspan="1">By fuel type used</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Biomass fuels only</td><td align="center" valign="top" rowspan="1" colspan="1">37</td><td align="center" valign="top" rowspan="1" colspan="1">308 (237 &#x02013; 378)</td><td align="center" valign="top" rowspan="1" colspan="1">708 (532 &#x02013; 884)</td><td align="center" valign="top" rowspan="1" colspan="1">9.0 (8.4 &#x02013; 9.7)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Both clean and biomass fuels</td><td align="center" valign="top" rowspan="1" colspan="1">49</td><td align="center" valign="top" rowspan="1" colspan="1">193 (167 &#x02013; 218)</td><td align="center" valign="top" rowspan="1" colspan="1">438 (374 &#x02013; 504)</td><td align="center" valign="top" rowspan="1" colspan="1">5.8 (5.6 &#x02013; 6.0)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Clean fuels only</td><td align="center" valign="top" rowspan="1" colspan="1">52</td><td align="center" valign="top" rowspan="1" colspan="1">165 (130 &#x02013; 200)</td><td align="center" valign="top" rowspan="1" colspan="1">390 (302 &#x02013; 479)</td><td align="center" valign="top" rowspan="1" colspan="1">5.0 (4.7 &#x02013; 5.2)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">By cooking stove location</td><td align="center" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Inside</td><td align="center" valign="top" rowspan="1" colspan="1">49</td><td align="center" valign="top" rowspan="1" colspan="1">181 (160 &#x02013; 203)</td><td align="center" valign="top" rowspan="1" colspan="1">415 (345 &#x02013; 485)</td><td align="center" valign="top" rowspan="1" colspan="1">5.8 (5.5 &#x02013; 6.1)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Outside</td><td align="center" valign="top" rowspan="1" colspan="1">49</td><td align="center" valign="top" rowspan="1" colspan="1">194 (166 &#x02013; 223)</td><td align="center" valign="top" rowspan="1" colspan="1">450 (382 &#x02013; 518)</td><td align="center" valign="top" rowspan="1" colspan="1">5.7 (5.5 &#x02013; 5.9)</td></tr><tr><td colspan="5" align="left" valign="top" rowspan="1">By season</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Winter</td><td align="center" valign="top" rowspan="1" colspan="1">22</td><td align="center" valign="top" rowspan="1" colspan="1">343 (295 &#x02013; 392)</td><td align="center" valign="top" rowspan="1" colspan="1">797 (675 &#x02013; 919)</td><td align="center" valign="top" rowspan="1" colspan="1">10.5 (10.2 &#x02013; 10.8)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Spring</td><td align="center" valign="top" rowspan="1" colspan="1">57</td><td align="center" valign="top" rowspan="1" colspan="1">121 (99 &#x02013; 143)</td><td align="center" valign="top" rowspan="1" colspan="1">281 (201 &#x02013; 360)</td><td align="center" valign="top" rowspan="1" colspan="1">4.1 (3.8 &#x02013; 4.3)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Monsoon</td><td align="center" valign="top" rowspan="1" colspan="1">64</td><td align="center" valign="top" rowspan="1" colspan="1">162 (120 &#x02013; 203)</td><td align="center" valign="top" rowspan="1" colspan="1">377 (278 &#x02013; 475)</td><td align="center" valign="top" rowspan="1" colspan="1">3.7 (3.5 &#x02013; 4.0)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Post-monsoon</td><td align="center" valign="top" rowspan="1" colspan="1">53</td><td align="center" valign="top" rowspan="1" colspan="1">117 (98 &#x02013; 136)</td><td align="center" valign="top" rowspan="1" colspan="1">255 (203 &#x02013; 306)</td><td align="center" valign="top" rowspan="1" colspan="1">4.9 (4.6 &#x02013; 5.2)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">By number of external windows and doors</td><td align="center" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/><td align="center" valign="top" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;2 or more</td><td align="center" valign="top" rowspan="1" colspan="1">52</td><td align="center" valign="top" rowspan="1" colspan="1">175 (149 &#x02013; 201)</td><td align="center" valign="top" rowspan="1" colspan="1">395 (335 &#x02013; 454)</td><td align="center" valign="top" rowspan="1" colspan="1">5.2 (5.0 &#x02013; 5.4)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;0 &#x02013; 1</td><td align="center" valign="top" rowspan="1" colspan="1">48</td><td align="center" valign="top" rowspan="1" colspan="1">223 (193 &#x02013; 253)</td><td align="center" valign="top" rowspan="1" colspan="1">535 (440 &#x02013; 630)</td><td align="center" valign="top" rowspan="1" colspan="1">6.8 (6.5 &#x02013; 7.2)</td></tr></tbody></table></table-wrap><table-wrap id="T3" position="float" orientation="portrait"><label>Table 3</label><caption><p>Population-averaged associations between time-weighted average and 90<sup>th</sup> percentile PM<sub>2.5</sub> concentrations and daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup> and household characteristics, fuel use, and season</p></caption><table frame="below" rules="groups"><thead><tr><th valign="top" rowspan="2" align="left" colspan="1"/><th colspan="3" valign="bottom" align="center" rowspan="1">
<hr/></th></tr><tr><th colspan="3" valign="top" align="center" rowspan="1">Coefficient (95% CI)</th></tr><tr><th colspan="4" valign="bottom" align="left" rowspan="1">
<hr/></th></tr><tr><th valign="top" align="left" rowspan="1" colspan="1"/><th valign="top" align="center" rowspan="1" colspan="1">Time-weighted average in &#x003bc;g/m<sup>3</sup></th><th valign="top" align="center" rowspan="1" colspan="1">90<sup>th</sup> percentile in &#x003bc;g/m<sup>3</sup></th><th valign="top" align="center" rowspan="1" colspan="1">Daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup></th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Primarily use biomass <xref rid="TFN1" ref-type="table-fn">&#x02260;</xref></td><td align="center" valign="top" rowspan="1" colspan="1">65 (6 &#x02013; 124)</td><td align="center" valign="top" rowspan="1" colspan="1">124 (-23 &#x02013; 272)</td><td align="center" valign="top" rowspan="1" colspan="1">1.9 (1.3 &#x02013; 2.5)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Ever use kerosene</td><td align="center" valign="top" rowspan="1" colspan="1">40 (&#x02212;4 &#x02013; 85)</td><td align="center" valign="top" rowspan="1" colspan="1">105 (&#x02212;6 &#x02013; 217)</td><td align="center" valign="top" rowspan="1" colspan="1">0.7 (0.3 &#x02013; 1.2)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Stove located inside home</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;19 (&#x02212;65 &#x02013; 28)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;48 (&#x02212;164 &#x02013; 68)</td><td align="center" valign="top" rowspan="1" colspan="1">0 (&#x02212;0.5 &#x02013; 0.5)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Tobacco smoked inside home</td><td align="center" valign="top" rowspan="1" colspan="1">0 (&#x02212;48 &#x02013; 48)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;8 (&#x02212;129 &#x02013; 113)</td><td align="center" valign="top" rowspan="1" colspan="1">0.6 (0.1 &#x02013; 1.1)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Per each external window and door</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;22 (&#x02212;43 &#x02013; &#x02212;0.2)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;56 (&#x02212;110 &#x02013; &#x02212;1)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;0.5 (&#x02212;0.7 &#x02013; &#x02212;0.2)</td></tr><tr><td colspan="4" align="left" valign="top" rowspan="1">Seasons <xref rid="TFN2" ref-type="table-fn">&#x0253c;</xref></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Winter</td><td align="center" valign="top" rowspan="1" colspan="1">225 (163 &#x02013; 287)</td><td align="center" valign="top" rowspan="1" colspan="1">537 (377 &#x02013; 696)</td><td align="center" valign="top" rowspan="1" colspan="1">5.6 (5.2 &#x02013; 6.0)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Spring</td><td align="center" valign="top" rowspan="1" colspan="1">3 (&#x02212;59 &#x02013; 66)</td><td align="center" valign="top" rowspan="1" colspan="1">24 (&#x02212;138 &#x02013; 184)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;0.9 (&#x02212;1.3 &#x02013; &#x02212;0.5)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Monsoon</td><td align="center" valign="top" rowspan="1" colspan="1">46 (&#x02212;13 &#x02013; 105)</td><td align="center" valign="top" rowspan="1" colspan="1">123 (&#x02212;26 &#x02013; 274)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;1.2 (&#x02212;1.5 &#x02013; &#x02212;0.8)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Intercept</td><td align="center" valign="top" rowspan="1" colspan="1">140 (67 &#x02013; 214)</td><td align="center" valign="top" rowspan="1" colspan="1">322 (137 &#x02013; 508)</td><td align="center" valign="top" rowspan="1" colspan="1">5.7 (4.6 &#x02013; 6.8)</td></tr></tbody></table><table-wrap-foot><fn id="TFN1"><label>&#x02260;</label><p>Compared to households that primarily use clean fuels</p></fn><fn id="TFN2"><label>&#x0253c;</label><p>Post-monsoon is the baseline</p></fn></table-wrap-foot></table-wrap><table-wrap id="T4" position="float" orientation="portrait"><label>Table 4</label><caption><p>Random effects coefficients representing changes in time-weighted average and 90<sup>th</sup> percentile PM<sub>2.5</sub> concentrations and daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup> associated with household characteristics, fuel use, and season</p></caption><table frame="below" rules="groups"><thead><tr><th rowspan="2" valign="top" align="left" colspan="1"/><th colspan="3" valign="bottom" align="center" rowspan="1">
<hr/></th></tr><tr><th colspan="3" valign="top" align="center" rowspan="1">Coefficient (95% CI)</th></tr><tr><th colspan="4" valign="bottom" align="left" rowspan="1">
<hr/></th></tr><tr><th valign="top" align="left" rowspan="1" colspan="1"/><th valign="top" align="center" rowspan="1" colspan="1">Time-weighted average in &#x003bc;g/m<sup>3</sup></th><th valign="top" align="center" rowspan="1" colspan="1">90<sup>th</sup> percentile in &#x003bc;g/m<sup>3</sup></th><th valign="top" align="center" rowspan="1" colspan="1">Daily hours &#x0003e;100 &#x003bc;g/m<sup>3</sup></th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Primarily use biomass <xref rid="TFN3" ref-type="table-fn">&#x02260;</xref></td><td align="center" valign="top" rowspan="1" colspan="1">65 (4 &#x02013; 125)</td><td align="center" valign="top" rowspan="1" colspan="1">124 (&#x02212;27 &#x02013; 275)</td><td align="center" valign="top" rowspan="1" colspan="1">1.9 (1.3 &#x02013; 2.5)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Ever use kerosene</td><td align="center" valign="top" rowspan="1" colspan="1">40 (&#x02212;6 &#x02013; 85)</td><td align="center" valign="top" rowspan="1" colspan="1">105 (&#x02212;9 &#x02013; 219)</td><td align="center" valign="top" rowspan="1" colspan="1">0.7 (0.2 &#x02013; 1.2)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Stove located inside home</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;19 (&#x02212;66 &#x02013; 29)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;48 (&#x02212;167 &#x02013; 71)</td><td align="center" valign="top" rowspan="1" colspan="1">0 (&#x02212;0.5 &#x02013; 0.5)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Tobacco smoked inside home</td><td align="center" valign="top" rowspan="1" colspan="1">0 (&#x02212;50 &#x02013; 49)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;8 (&#x02212;132 &#x02013; 116)</td><td align="center" valign="top" rowspan="1" colspan="1">0.6 (0.1 &#x02013; 1.1)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Per each external window and door</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;22 (&#x02212;44 &#x02013; 0)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;55 (&#x02212;111 &#x02013; 0)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;0.5 (&#x02212;0.7 &#x02013; &#x02212;0.2)</td></tr><tr><td colspan="4" align="left" valign="top" rowspan="1">Seasons <xref rid="TFN4" ref-type="table-fn">&#x0253c;</xref></td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Winter</td><td align="center" valign="top" rowspan="1" colspan="1">225 (163 &#x02013; 287)</td><td align="center" valign="top" rowspan="1" colspan="1">537 (377 &#x02013; 696)</td><td align="center" valign="top" rowspan="1" colspan="1">5.6 (5.2 &#x02013; 6.0)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Spring</td><td align="center" valign="top" rowspan="1" colspan="1">4 (&#x02212;59 &#x02013; 66)</td><td align="center" valign="top" rowspan="1" colspan="1">24 (&#x02212;137 &#x02013; 184)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;0.9 (&#x02212;1.3 &#x02013; &#x02212;0.5)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">&#x02003;Monsoon</td><td align="center" valign="top" rowspan="1" colspan="1">46 (&#x02212;13 &#x02013; 105)</td><td align="center" valign="top" rowspan="1" colspan="1">124 (&#x02212;26 &#x02013; 274)</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;1.2 (&#x02212;1.5 &#x02013; &#x02212;0.8)</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Intercept</td><td align="center" valign="top" rowspan="1" colspan="1">140 (66 &#x02013; 215)</td><td align="center" valign="top" rowspan="1" colspan="1">323 (134 &#x02013; 511)</td><td align="center" valign="top" rowspan="1" colspan="1">5.1 (4.4 &#x02013; 5.7)</td></tr></tbody></table><table-wrap-foot><fn id="TFN3"><label>&#x02260;</label><p>Compared to households that primarily use clean fuels</p></fn><fn id="TFN4"><label>&#x0253c;</label><p>Post-monsoon is the baseline</p></fn></table-wrap-foot></table-wrap><boxed-text id="BX1" position="float" orientation="portrait"><caption><title>Highlight</title></caption><list list-type="bullet"><list-item><p id="P28">We described the determinants of indoor particulate matter in Dhaka, Bangladesh.</p></list-item><list-item><p id="P29">Particulate matter concentrations were 7 times higher than recommended levels.</p></list-item><list-item><p id="P30">All homes had high levels of particulate matter, regardless of cooking fuel type.</p></list-item><list-item><p id="P31">The strongest determinant of indoor particulate matter was season.</p></list-item></list></boxed-text></floats-group></article>