<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="article-commentary"><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">9422759</journal-id><journal-id journal-id-type="pubmed-jr-id">2553</journal-id><journal-id journal-id-type="nlm-ta">Occup Environ Med</journal-id><journal-id journal-id-type="iso-abbrev">Occup Environ Med</journal-id><journal-title-group><journal-title>Occupational and environmental medicine</journal-title></journal-title-group><issn pub-type="ppub">1351-0711</issn><issn pub-type="epub">1470-7926</issn></journal-meta><article-meta><article-id pub-id-type="pmid">23940192</article-id><article-id pub-id-type="pmc">4539563</article-id><article-id pub-id-type="doi">10.1136/oemed-2013-101641</article-id><article-id pub-id-type="manuscript">HHSPA714318</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Dampness and mould in schools and respiratory
symptoms</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Kreiss</surname><given-names>Kathleen</given-names></name></contrib></contrib-group><author-notes><corresp id="cor1"><bold>Correspondence to</bold> Div Respiratory Disease, Studies,
1095 Willowdale Rd, Morgantown West Virginia, USA 26505,
<email>KKreiss@cdc.gov</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>10</day><month>8</month><year>2015</year></pub-date><pub-date pub-type="epub"><day>12</day><month>8</month><year>2013</year></pub-date><pub-date pub-type="ppub"><month>10</month><year>2013</year></pub-date><pub-date pub-type="pmc-release"><day>18</day><month>8</month><year>2015</year></pub-date><volume>70</volume><issue>10</issue><fpage>679</fpage><lpage>680</lpage><!--elocation-id from pubmed: 10.1136/oemed-2013-101641--><related-article related-article-type="commentary-article" xlink:href="23775866" ext-link-type="pmid" id="ra1" xlink:type="simple"/></article-meta></front><body><p id="P1">Indoor dampness is associated with respiratory symptoms in studies of homes and
their occupants in many nations.<sup><xref rid="R1" ref-type="bibr">1</xref></sup>
Specific office building populations have allowed study of incident diagnoses such as
building-related asthma and hypersensitivity pneumonitis in relation to damp indoor
environments, with incidence density of such diagnoses increased as much as sevenfold
after occupancy of a damp office building compared with the prior period during
adulthood.<sup><xref rid="R2" ref-type="bibr">2</xref><xref rid="R3" ref-type="bibr">3</xref></sup> Study of large numbers of persons in
one building or school is more efficient than studies of occupants of many dwellings and
allows increased precision in exposure classification for individuals. Within a single
or small number of damp buildings, both measured microbial markers and observational
grading of moisture indices are associated with a risk of building-related respiratory
symptoms and diagnoses among occupants. <sup><xref rid="R4" ref-type="bibr">4</xref>&#x02013;<xref rid="R7" ref-type="bibr">7</xref></sup> However,
effective regulation in most countries requires demonstration of consistent
relationships between environmental measurements and health risk across many buildings,
and such evidence is lacking to date. The body of work underway in the HITEA
study<sup><xref rid="R8" ref-type="bibr">8</xref></sup> is motivated in part to
examine whether aggregated populations from many schools have a differential risk of
respiratory health outcomes in relation to dampness indices and, if so, whether there
are environmental measurements that are associated with risk. Ironically, the home
environment will not be subject to effective regulation in most countries, despite the
strongest body of evidence that dwelling dampness is associated with respiratory health
risk.</p><p id="P2">The paper by Borr&#x000e0;s-Santos <italic>et al</italic><sup><xref rid="R8" ref-type="bibr">8</xref></sup> extends the study of school children
from homes to damp and dry school environments. In all countries, children attending
damp schools had higher odds of nocturnal dry cough. The inconsistent findings for other
symptoms in the three countries are provocative. Finnish children had strong evidence of
dampness-related increases in many respiratory indices in an exposure-dependent manner,
but Spanish children in damp schools demonstrated increased symptoms (nasal symptoms
apart from cold) only when analyses were limited to schools with somewhat modest
response rates of 60% or higher, and Dutch children had no other
dampness-related ill effects apart from nocturnal cough. Building-related nasal symptoms
are a risk factor for developing building-associated asthma symptoms.<sup><xref rid="R9" ref-type="bibr">9</xref></sup> Since there is no reason for
dampness-related adverse respiratory symptoms to differ by location of exposure in homes
or schools, these country differences regarding school environments will lead to further
hypotheses which may narrow the uncertainties about what investigators should measure in
assessing indoor environmental risk. Certainly damp homes outside the Nordic climate
have been shown to confer respiratory health risks, as have environmental measurements
in single damp office buildings and schools across many latitudes.</p><p id="P3">One obvious source of the inconsistent findings across countries is
misclassification of exposure. The investigators assumed that all children in a damp
school had the same exposure. Certainly, within single damp office buildings and schools
with building-related respiratory complaints, room- and workstation-specific dampness
indices and measured exposures in vacuumed dusts have shown exposure-response
relationships with risk of building-related symptoms.<sup><xref rid="R4" ref-type="bibr">4</xref>&#x02013;<xref rid="R7" ref-type="bibr">7</xref></sup> Thus
microenvironments exist within buildings, and ignoring them makes demonstration of
relationships between environmental dampness and respiratory outcomes less likely.
Perhaps mechanical ventilation present in Finnish schools (but absent in Spain and The
Netherlands) homogenises exposures from structural dampness and lessens
misclassification of exposure by school. Misclassification of health outcome is also a
potential problem in between-country comparisons, especially with language and clinical
care differences. In both Spain and Finland, a parent-reported asthma diagnosis was
insensitive for report of wheezing and use of respiratory medication in comparison with
school populations in The Netherlands.</p><p id="P4">School environments are a societal responsibility,<sup><xref rid="R10" ref-type="bibr">10</xref></sup> unlike the home environment or the workplace over
which property owners preside. Although employers&#x02019; workplaces are poorly
regulated with regard to indoor environmental quality, adults have some ability to
choose their workplaces, subject to socioeconomic barriers such as high unemployment
rates. This is rarely true for choice of school environments by adults for their
children, nearly all of whom attend school. The commitment to social justice for
children from different walks of life in having equivalent educational
environments<sup><xref rid="R11" ref-type="bibr">11</xref></sup> appears
violated in the data presented in this multinational study: Finnish and Spanish students
with parents having low educational levels were statistically more likely to attend damp
schools and Spanish students of immigrant origin similarly were more likely to attend
damp schools. In Finland, school absence for respiratory illness was associated with
dampness indices in an exposure-dependent manner. Thus, ill health and absenteeism might
align in affecting academic performance in an inequitable way across the socioeconomic
spectrum.<sup><xref rid="R11" ref-type="bibr">11</xref></sup></p><p id="P5">The search for building characteristics and materials associated with health risk
and dampness requires continued investigation to elucidate remediable causes and
improved health of all children. Such information will be valuable for healthy housing
and healthy information will be valuable for healthy housing and healthy workplaces as
well. In the meantime, intervention for dampness is warranted when building occupants
have chest symptoms, despite the absence of quantitative environmental measures of
risk.<sup><xref rid="R12" ref-type="bibr">12</xref></sup></p></body><back><fn-group><fn id="FN1" fn-type="con"><p id="P6"><bold>Contributors</bold> This commentary was prepared in the course of
the author&#x02019;s employment at the US National Institute for Occupational
Safety and Health, Centers for Disease Control and Prevention.</p></fn><fn id="FN2"><p id="P7"><bold>Competing interests</bold> None.</p></fn><fn id="FN3"><p id="P8"><bold>Provenance and peer review</bold> Commissioned; internally peer
reviewed.</p></fn></fn-group><ref-list><title>References</title><ref id="R1"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mendell</surname><given-names>MJ</given-names></name><name><surname>Mirer</surname><given-names>AG</given-names></name><name><surname>Cheung</surname><given-names>K</given-names></name><etal/></person-group><article-title>Respiratory and allergic health effects of dampness, mold, and
dampness-related agents: a review of the epidemiologic
evidence</article-title><source>Environ Health Perspect</source><year>2011</year><volume>119</volume><fpage>748</fpage><lpage>56</lpage><pub-id pub-id-type="pmid">21269928</pub-id></element-citation></ref><ref id="R2"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cox-Ganser</surname><given-names>JM</given-names></name><name><surname>White</surname><given-names>SK</given-names></name><name><surname>Jones</surname><given-names>R</given-names></name><etal/></person-group><article-title>Respiratory morbidity in office workers in a water-damaged
building</article-title><source>Environ Health Perspect</source><year>2005</year><volume>113</volume><fpage>485</fpage><lpage>90</lpage><pub-id pub-id-type="pmid">15811840</pub-id></element-citation></ref><ref id="R3"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Laney</surname><given-names>AS</given-names></name><name><surname>Cragin</surname><given-names>LA</given-names></name><name><surname>Blevins</surname><given-names>LZ</given-names></name><etal/></person-group><article-title>Sarcoidosis, asthma, and asthma-like symptoms among occupants of
a historically water-damaged office building</article-title><source>Indoor Air</source><year>2009</year><volume>19</volume><fpage>83</fpage><lpage>90</lpage><pub-id pub-id-type="pmid">19191928</pub-id></element-citation></ref><ref id="R4"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cox-Ganser</surname><given-names>JM</given-names></name><name><surname>Rao</surname><given-names>CY</given-names></name><name><surname>Park</surname><given-names>J-H</given-names></name><etal/></person-group><article-title>Asthma and respiratory symptoms in hospital workers related to
dampness and biological contaminants</article-title><source>Indoor Air</source><year>2009</year><volume>19</volume><fpage>280</fpage><lpage>90</lpage><pub-id pub-id-type="pmid">19500175</pub-id></element-citation></ref><ref id="R5"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Park</surname><given-names>J-H</given-names></name><name><surname>Schleiff</surname><given-names>PL</given-names></name><name><surname>Attfield</surname><given-names>MD</given-names></name><etal/></person-group><article-title>Building-related respiratory symptoms can be predicted with
semi-quantitative indices of exposure to dampness and mold</article-title><source>Indoor Air</source><year>2004</year><volume>14</volume><fpage>425</fpage><lpage>33</lpage><pub-id pub-id-type="pmid">15500636</pub-id></element-citation></ref><ref id="R6"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Park</surname><given-names>J-H</given-names></name><name><surname>Cox-Ganser</surname><given-names>J</given-names></name><name><surname>Rao</surname><given-names>C</given-names></name><etal/></person-group><article-title>Fungal and endotoxin measurements in dust associated with
respiratory symptoms in a water-damaged office building</article-title><source>Indoor Air</source><year>2006</year><volume>16</volume><fpage>192</fpage><lpage>203</lpage><pub-id pub-id-type="pmid">16683938</pub-id></element-citation></ref><ref id="R7"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Park</surname><given-names>J-H</given-names></name><name><surname>Cox-Ganser</surname><given-names>JM</given-names></name><name><surname>Kreiss</surname><given-names>K</given-names></name><etal/></person-group><article-title>Hydrophilic fungi and ergosterol associated with respiratory
illness in a water-damaged building</article-title><source>Environ Health Perspect</source><year>2008</year><volume>116</volume><fpage>45</fpage><lpage>50</lpage><pub-id pub-id-type="pmid">18197298</pub-id></element-citation></ref><ref id="R8"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Borr&#x000e0;s-Santos</surname><given-names>A</given-names></name><name><surname>Jacobs</surname><given-names>JH</given-names></name><name><surname>Taubel</surname><given-names>M</given-names></name><etal/></person-group><article-title>Dampness and mould in schools and respiratory symptoms in
children: the HITEA study</article-title><source>Occup Environ Med</source><year>2013</year><month>6</month><day>17</day><comment>Published Online First</comment></element-citation></ref><ref id="R9"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Park</surname><given-names>J-H</given-names></name><name><surname>Kreiss</surname><given-names>K</given-names></name><name><surname>Cox-Ganser</surname><given-names>JM</given-names></name></person-group><article-title>Rhinosinusitis and mold as risk factors for asthma symptoms in
occupants of a water-damaged building</article-title><source>Indoor Air</source><year>2012</year><volume>22</volume><fpage>396</fpage><lpage>404</lpage><pub-id pub-id-type="pmid">22385263</pub-id></element-citation></ref><ref id="R10"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jones</surname><given-names>SE</given-names></name><name><surname>Fisher</surname><given-names>CJ</given-names></name><name><surname>Greene</surname><given-names>BZ</given-names></name><etal/></person-group><article-title>Healthy and safe school environment, Part I: results from the
school health policies and programs study 2006</article-title><source>J School Health</source><year>2007</year><volume>77</volume><fpage>522</fpage><lpage>43</lpage><pub-id pub-id-type="pmid">17908106</pub-id></element-citation></ref><ref id="R11"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Okeu</surname><given-names>S</given-names></name><name><surname>Ryherd</surname><given-names>E</given-names></name><name><surname>Bayer</surname><given-names>C</given-names></name></person-group><article-title>The role of physical environment on student health and education
in green schools</article-title><source>Rev Environ Health</source><year>2011</year><volume>26</volume><fpage>169</fpage><lpage>79</lpage><pub-id pub-id-type="pmid">22206193</pub-id></element-citation></ref><ref id="R12"><label>12</label><element-citation publication-type="book"><collab>Centers for Disease Control</collab><source>NIOSH Alert: Preventing occupational respiratory disease from exposures
caused by dampness in office buildings, schools, and other nonindustrial
buildings</source><publisher-loc>Cincinnati, Ohio</publisher-loc><publisher-name>US Department of Health and Human Services
(NIOSH)</publisher-name><comment>Publication No. 2013-102, 2012.</comment></element-citation></ref></ref-list></back></article>