On October 12, 2001, two envelopes containing
In the fall of 2001, 22 cases of anthrax were confirmed or suspected throughout the eastern United States as a result of bioterrorist release of spores (
At the time of the anthrax release in the fall of 2001, little was known about the re-aerosolization potential of
To address the question of continued risk for workers, we conducted an expanded safety evaluation of the partially remediated mail facility. A stamp on one of the two contaminated envelopes indicated that it had passed through Delivery Bar Code Sorter machine no. 17 at the Brentwood mail facility. This sorter, which had been idle for >2 weeks, had been cleaned with 0.5% hypochlorite solution before our testing. We evaluated the potential health risk to workers near that sorter by activating it and conducting surface and air sampling.
Two surface sampling techniques were used. Rodac plates (65-mm tryptic soy agar [TSA] plates; Becton-Dickinson, Franklin Lakes, NJ) were pressed onto the surface being sampled. Immediately adjacent to the Rodac sampling site, swab sampling was performed with sterile rayon-tipped swabs moistened with a 0.5-mL solution of phosphate-buffered saline + 0.05% Tween 20 (PBS Tween). An approximately 100-cm2 area was swabbed with sequential vertical, horizontal, and diagonal strokes. The swabs were individually placed in sterile, dry 15-mL conical tubes. Sampling focused on areas in the machine (electrical components, beneath belts, etc.) that were unlikely to have been cleaned with the topical bleach application.
The ventilation system in the mail facility was turned off when the facility closed, and the system remained off during testing. We were unable to simulate the “blow-down” procedure (used to clean the sorter) during testing because the air compressors for the air hoses had lost power. Machine operators typically use high-pressure hoses several times a day to clean accumulated dust and debris between mail-sorting runs. Two banks of 10-slit samplers were placed on two postal trolleys (approximately 5 feet above the floor) and connected to a vacuum pump. The slit sampler intake ports were approximately 10 inches above the trolley. Each of the samplers was loaded with 150-mm TSA plates. Slit sampler set “A” (SSSA) was placed next to the operator’s station (at a location and height where workers would spend most of their time), and slit sampler set “B” (SSSB) was placed at the opposite end of the sorter (
Sites and results of surface sampling for
SSSB was activated and ran for 20 min while the sorter was turned off. SSSA was then activated and ran for 10 min. The plates were removed from all slit samplers and new plates were loaded. The SSSA and SSSB design characteristics determined the duration of sampling.
Both sets of slit samplers were activated simultaneously while the sorter was inactive. Approximately 1 min later, the sorter was started, and clean dummy mail was processed. After several false starts, continuous operation was achieved in approximately 2 min. The operation of the sorter was interrupted several times by jammed envelopes and quickly restarted each time, until the machine was turned off 1 min before the end of the 20-min sampling period. Postal officials reported that false starts, jamming, and restarting are common during routine operation of the machine.
As with the previous sampling, SSSA ran for 10 min and SSSB ran for 20 min. The plates were removed from the slit samplers and sealed in plastic bags. The bagged plates were taken out of the facility and the exteriors of the bags were decontaminated with 0.5% hypochlorite solution.
The sampling team was outfitted with Canadian military C4 respirators with C7 canisters. The mask was equipped with 37-mm glass fiber collection filters mounted on the inlet port of the C7 canister, so that the entire inspirational volume of the investigators was sampled. The masked team members were located near the sorter to provide additional point sampling of respirable aerosol during the experiment. Team members were stationed at different work sites along the sorter and elsewhere in the facility to serve as point detectors. All mask filters were worn for at least 2 h.
Environmental swabs and TSA plates from the Rodac plates and slit samplers were stored at 4°C until shipped and processed. All specimens were shipped at room temperature overnight to the Centers for Disease Control and Prevention. Swabs were placed in 1.5 mL PBS-Tween and vortexed for approximately 1 min. The solution was heat-shocked at 65°C for 30 min, and 100 µL was plated onto a sheep blood agar (SBA) plate. Rodac and slit sampler plates were incubated for approximately 12 h, and CFU were counted by visual inspection. All colonies suspected to be
Numbers of colonies detected in air sampling before and after the machine was activated were assessed with a one-sided one-sample test for difference in rates from a binomial distribution by using StatExact 4 v. 4.0.1. (Cytel Software Corp., Cambridge, MA).
Surface sampling was done by two methods, Rodac plates and premoistened swabs, to establish that the machine was still contaminated with viable
A single colony of
After the sorter was activated, SSSA and SSSB ran for 10 min and 20 min, respectively. A single colony of
| Time (min) | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 | 19 | 20 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Sampler A | +a | |||||||||||||||||||
| Sampler B | + | + | + | + | + | |||||||||||||||
a+, positive for
Five investigators wore mask filters while the sorting machine was inactive; four investigators changed to new mask filters while the sorting machine was active. All mask filters were negative by culture.
New questions have arisen as public health authorities have investigated and responded to the intentional release of
Initial reports indicated that no specific remediation had yet been undertaken on the contaminated machine. Subsequently, we learned that the surface of the sorter implicated in processing the contaminated envelopes had been cleaned with 0.5% hypochlorite solution. We proceeded with testing because the expectation was that topical cleaning would provide only fractional decontamination of a contaminated machine. By focused sampling, we found that, despite topical cleaning, the sorter remained contaminated with
Air sampling detected
Environmental surface sampling done shortly after the Brentwood mail facility was closed found widespread contamination of the facility with
Based on these concentrations and assuming 100% sampler collection efficiency, the estimated number of
The comparison of this type of exposure with nonhuman primate anthrax data and historical industrial anthrax data is problematic for several reasons. Our understanding of human infection risk at very low-dose
This study shows that a mail sorter may remain contaminated, as indicated by surface sampling, many days after processing
Further studies are essential to define the risks of inhalational anthrax in the settings of both primary and secondary aerosolization of
The authors acknowledge the extraordinary efforts of Timothy Haney and Louis Higginbotham, United States Postal Services Washington D.C. Processing and Distribution Center, in carrying out the investigation.
Dr. Dull is an Epidemic Intelligence Service officer in the Meningitis and Special Pathogens Branch, National Center for Infectious Diseases, Centers for Disease Control and Prevention. His recent field epidemiology investigations include febrile illness surveillance in Nepal, meningitis outbreaks in Ethiopia and Montgomery County, Texas, and human cutaneous anthrax associated with an epizootic in North Dakota.