<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD v1.0 20120330//EN" "JATS-archivearticle1.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties manuscript?><front><journal-meta><journal-id journal-id-type="nlm-journal-id">7708433</journal-id><journal-id journal-id-type="pubmed-jr-id">22734</journal-id><journal-id journal-id-type="nlm-ta">Opt Lett</journal-id><journal-id journal-id-type="iso-abbrev">Opt Lett</journal-id><journal-title-group><journal-title>Optics letters</journal-title></journal-title-group><issn pub-type="ppub">0146-9592</issn><issn pub-type="epub">1539-4794</issn></journal-meta><article-meta><article-id pub-id-type="pmid">23939121</article-id><article-id pub-id-type="pmc">3759812</article-id><article-id pub-id-type="manuscript">NIHMS500772</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Optical clearing-aided photoacoustic microscopy with enhanced resolution and imaging depth</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Zhou</surname><given-names>Yong</given-names></name><xref rid="FN2" ref-type="author-notes">&#x02020;</xref></contrib><contrib contrib-type="author"><name><surname>Yao</surname><given-names>Junjie</given-names></name><xref rid="FN2" ref-type="author-notes">&#x02020;</xref></contrib><contrib contrib-type="author"><name><surname>Wang</surname><given-names>Lihong V.</given-names></name><xref rid="FN1" ref-type="author-notes">*</xref></contrib><aff id="A1">Optical Imaging Laboratory, Department of Biomedical Engineering, Washington University in St. Louis, One Brookings Drive, St. Louis, MO 63130, USA</aff></contrib-group><author-notes><corresp id="FN1"><label>*</label>Corresponding author: <email>lhwang@wustl.edu</email></corresp><fn id="FN2" fn-type="equal"><label>&#x02020;</label><p>There authors contributed equally to this work.</p></fn></author-notes><pub-date pub-type="nihms-submitted"><day>10</day><month>8</month><year>2013</year></pub-date><pub-date pub-type="ppub"><day>15</day><month>7</month><year>2013</year></pub-date><pub-date pub-type="pmc-release"><day>03</day><month>9</month><year>2013</year></pub-date><volume>38</volume><issue>14</issue><fpage>2592</fpage><lpage>2595</lpage><permissions><copyright-statement>&#x000a9; 2013 Optical Society of America</copyright-statement><copyright-year>2013</copyright-year></permissions><abstract><p id="P1">Due to strong light scattering in tissue, both the spatial resolution and maximum penetration depth of optical-resolution photoacoustic microscopy (OR-PAM) deteriorate sharply with depth. To reduce tissue scattering, we propose to use glycerol as an optical clearing agent in OR-PAM. Our results show that the imaging performance of OR-PAM can be greatly enhanced by optical clearing both <italic>in vitro</italic> and <italic>in vivo</italic>.</p></abstract></article-meta></front><body><p id="P2">Photoacoustic microscopy (PAM) is a recently developed imaging modality that can provide structural [<xref rid="R1" ref-type="bibr">1</xref>], molecular [<xref rid="R2" ref-type="bibr">2</xref>], functional [<xref rid="R3" ref-type="bibr">3</xref>&#x02013;<xref rid="R5" ref-type="bibr">5</xref>], and metabolic information [<xref rid="R6" ref-type="bibr">6</xref>]. Based on its focusing mechanism, PAM can be divided into two different implementations: acoustic-resolution PAM (AR-PAM) and optical-resolution PAM (OR-PAM) [<xref rid="R1" ref-type="bibr">1</xref>]. In OR-PAM, the lateral resolution is determined by the diffraction-limited optical focusing. As photons travel in tissue, the focusing capability degrades due to optical scattering. In addition, the maximum penetration depth of OR-PAM in biological tissue is mainly limited by the optical transport mean free path, affected by both absorption and scattering. Since the tissue scattering is typically an order of magnitude larger than the absorption, it is the scattering that predominantly limits the penetration depth of OR-PAM [<xref rid="R7" ref-type="bibr">7</xref>].</p><p id="P3">To reduce the scattering, tissue optical clearing (TOC) techniques have been widely used in many high-resolution optical imaging modalities, such as laser speckle contrast imaging and optical coherence tomography [<xref rid="R8" ref-type="bibr">8</xref>]. The basic mechanism of TOC is to diffuse a high-refractive-index optical clearing agent (OCA) into the tissue, which reduces the refractive index mismatch between intracellular components and extracellular fluids, and thus decreases the scattering. In addition, tissue dehydration caused by OCAs has also been used to explain TOC [<xref rid="R8" ref-type="bibr">8</xref>]: on one hand, it increases refractive-index matching due to decreased volume fraction of free water in the interstitial fluid; on the other hand, it increases packing of scatters, which may engender spatial correlations between scatterings; both reduce scattering further. In this paper, for the first time, we demonstrate that both the imaging depth and lateral resolution of OR-PAM can be enhanced by using a glycerol-water solution (88%, vol/vol), which is a commonly used OCA in TOC.</p><p id="P4">We implemented this idea on a previously reported OR-PAM system (<xref rid="F1" ref-type="fig">Fig. 1</xref>). Briefly, a tunable dye laser (CBR-D, Sirah, GmbH.) pumped by a Nd:YLF laser (INNOSAB, Edgewave, GmbH.) was the light source. After being focused by a condenser lens, filtered by a pinhole, and reflected by a mirror, the laser beam was finally focused by an objective lens into the sample. Ultrasonic detection was achieved by a wide-band ultrasonic transducer (V214-BC, Panametrics-NDT Inc.), which was placed confocally with the optical objective lens. Each laser pulse yielded a one-dimensional depth-resolved PA image (A-line) by recording the time course of photoacoustic signals. A three-dimensional (3D) image was obtained by raster scanning the sample and piecing together A-lines.</p><p id="P5">First, in a phantom experiment, a U.S. penny (<xref rid="F2" ref-type="fig">Fig. 2a</xref>) covered by a piece of freshly harvested mouse skin was imaged at 570 nm. The phantom was immersed in the glycerol-water solution. As shown in the baseline image [<xref rid="F2" ref-type="fig">Fig. 2(b)</xref>], there were almost no PA signals from the coin because of the strong scattering of the mouse tissue. During optical clearing, the PA signals from the coin became stronger and stronger, and more features became resolvable, as shown from <xref rid="F2" ref-type="fig">Fig. 2(c) to (d)</xref>. <xref rid="F2" ref-type="fig">Fig. 2(e)</xref> shows that the average total PA signal amplitude from the coin versus time; after 250 min, the amplitude increased by more than three fold over the baseline value. Note that the PA signals were still increasing at the point when we stopped the experiment. This phantom experiment clearly illustrates that the scattering of the tissue was reduced by optical clearing, and thus the penetration depth was enhanced.</p><p id="P6">Next, we used a nude mouse in an in vivo experiment. All experimental animal procedures were carried out in conformance with the laboratory animal protocol approved by the Animal Studies Committee of Washington University in St. Louis. Because the diffusion of glycerol across the epidermal layer is very slow, we directly injected the glycerol-water solution into the mouse scalp to create a local optical clearing window. <xref rid="F3" ref-type="fig">Figs. 3(a) and (b)</xref> show the maximum-amplitude-projection (MAP) of the PA images of blood vessels in the mouse scalp before and after optical clearing, respectively. For a better visualization of the deeper vessels in the scalp, we digitally removed most of the superficial capillaries seen in <xref rid="F3" ref-type="fig">Fig. 3(b)</xref>, with the result shown in <xref rid="F3" ref-type="fig">Fig. 3(c)</xref>. From <xref rid="F3" ref-type="fig">Figs. 3(a)&#x02013;(c)</xref>, we can see a clear PA signal amplitude enhancement after optical clearing. Three representative lines were taken from <xref rid="F3" ref-type="fig">Figs. 3(a)&#x02013;(c)</xref> for further comparison, as shown in <xref rid="F3" ref-type="fig">Figs. 3(d)&#x02013;(f)</xref>. The averaged PA amplitude had increased by about eight times after optical clearing.</p><p id="P7">We also quantified the optical clearing effect along the depth direction, as shown in <xref rid="F3" ref-type="fig">Figs. 3(g)&#x02013;(h)</xref>. To quantify the total signal enhancement after optical clearing, the averaged PA signal amplitude along the depth was calculated and is shown in <xref rid="F3" ref-type="fig">Fig. 3(i)</xref>. Based on Beer&#x02019;s law, the fitted attenuation coefficients before and after optical clearing were 57.4 cm-1 and 103.1 cm-1, respectively. At first glance, the attenuation appears to have increased after optical clearing. However, since dehydration due to optical clearing caused the total thickness of the tissue to decrease by about 2.57 times [<xref rid="F3" ref-type="fig">Figs. 3(g)&#x02013;(h)</xref>], the scatter and absorber number density should increase by about 2.57 times. If both the scattering and absorption cross section had remained constant after optical clearing, the attenuation coefficient should have increased by 2.57 times rather than the 1.80 times observed in the experiment. Thus, the scattering or absorption cross section was reduced after optical clearing. Because optical clearing did not affect the absorption cross section, we concluded that the 0.77 times less increase in the attenuation coefficient resulted from the decrease in the scattering cross section. <xref rid="F3" ref-type="fig">Figs. 3(j) (Media 1) and (k) (Media 2)</xref> show 3D renderings of the mouse scalp before and after optical clearing, respectively.</p><p id="P8">The enhanced PA detection sensitivity after optical clearing enabled better capillary imaging [<xref rid="F3" ref-type="fig">Fig. 3(b)</xref>]. <xref rid="F4" ref-type="fig">Fig. 4(a) and (b)</xref> are close-up images of the red-dashed-square areas in <xref rid="F3" ref-type="fig">Figs. 3(a) and (b)</xref>, respectively. The large vessels in the periphery of both images indicate that they are from the same area in the mouse scalp. As shown in <xref rid="F4" ref-type="fig">Fig. 4(a)</xref>, very few capillaries can be detected before optical clearing. However, after optical clearing, more capillaries can be distinctly observed, as shown in <xref rid="F4" ref-type="fig">Fig. 4(b)</xref>. As shown in <xref rid="F4" ref-type="fig">Figs. 4(c)&#x02013;(d)</xref>, the vessel density increased by about 10 times after clearing, and the averaged PA signal amplitude from individual capillaries increased by a factor of 22. The much denser capillaries and stronger PA amplitudes in <xref rid="F4" ref-type="fig">Fig. 4(d)</xref> indicate that, after optical clearing, the local laser fluence at the capillaries was increased. There were two possible reasons for the increased local laser fluence: (1) enhanced focusing on these capillaries due to the dehydration-induced shrinkage of the tissue, and (2) reduced scattering loss. As shown in <xref rid="F3" ref-type="fig">Fig. 3(i)</xref>, because of dehydration, the averaged thickness of the tissue decreased from about 0.88 mm to 0.37 mm. Assuming the light beam intensity had a Gaussian shape, we estimated that the average fluence increase caused by shrinkage was about 5 times. Therefore, we can conclude that the remaining 4.4 fold increase of the PA signal amplitude was due to the decreased scattering coefficient. Because the background noise remained constant during the experiment, the noise-equivalent sensitivity depended only on the PA signal amplitude. Therefore, sensitivity should also increase 4.4 times due to the decreased scattering coefficient.</p><p id="P9">We further analyzed the lateral resolution enhancement after optical clearing. By zooming in on the deeper vessels in <xref rid="F3" ref-type="fig">Figs. 3(a)&#x02013;(b)</xref>, we found that the vessels before optical clearing were much more blurred than those after optical clearing, as shown in <xref rid="F5" ref-type="fig">Figs. 5(a) and (b)</xref>. Again, the averaged PA amplitude was increased by about 5 times [<xref rid="F5" ref-type="fig">Figs. 5(c)&#x02013;(d)</xref>]. More importantly, we also estimated the lateral resolution improvement by comparing the vessel diameters. As shown in <xref rid="F5" ref-type="fig">Fig. 5(e)</xref>, a representative vessel had nominal diameters of 75 &#x003bc;m and 30 &#x003bc;m before and after clearing, respectively. We can see that measured vessel diameter decreased at least by 2.5 times after optical clearing. Because the measured vessel diameter was the convolution of the actual lateral resolution with the true vessel diameter, the actual resolution improvement should be better than 2.5 times.</p><p id="P10">There are several widely used OCAs, such as glycerol [<xref rid="R8" ref-type="bibr">8</xref>], glucose [<xref rid="R9" ref-type="bibr">9</xref>&#x02013;<xref rid="R10" ref-type="bibr">10</xref>], and propylene glycol [<xref rid="R11" ref-type="bibr">11</xref>]. Among these agents, glycerol has both good clearing efficiency and a long effective time. In addition, because glycerol has also been widely used in the medical, pharmaceutical, and chemical fields, it can be easily accessed. Thus, in all experiments, we elected to use glycerol as the OCA to reduce tissue scattering. To achieve a relatively good clearing result and to reduce the potential tissue damage caused by dehydration, a diluted glycerol-water solution (88%, vol/vol) was used [<xref rid="R11" ref-type="bibr">11</xref>]. A higher glycerol concentration may enhance the clearing effect with a higher risk of tissue damage [<xref rid="R12" ref-type="bibr">12</xref>].</p><p id="P11">Because glycerol penetrates very slowly through epidermal tissue, we directly injected the glycerol solution into the tissue to accelerate optical clearing. However, injection may lead to side effects, such as bleeding and edema [<xref rid="R12" ref-type="bibr">12</xref>]. To use glycerol without injection, we can explore either physical or chemical approaches, such as using a micro needle array or a dimethyl sulfoxide (DMSO) admixture, respectively [<xref rid="R8" ref-type="bibr">8</xref>]. Because high-concentration glycerol may block blood flow [<xref rid="R13" ref-type="bibr">13</xref>&#x02013;<xref rid="R14" ref-type="bibr">14</xref>], other safer optical clearing media, such as PEG-400 mixed with thiazone [<xref rid="R15" ref-type="bibr">15</xref>&#x02013;<xref rid="R16" ref-type="bibr">16</xref>], should be explored in the future.</p><p id="P12">To the best of our knowledge, this is the first time that optical clearing was applied to PAM. Our results show that both the penetration depth and lateral resolution of PA imaging can be enhanced by TOC. For back-scattering based optical imaging modalities such as optical coherence tomography, optical clearing can provide deeper penetration depth as well. However, it may destroy some of the intrinsic scattering contrasts that these modalities rely on, which can result in potential information loss. By contrast, photoacoustic imaging is based on optical absorption with 100% sensitivity [<xref rid="R1" ref-type="bibr">1</xref>]. Since the optical absorption cross section of the substance (e.g., hemoglobin) remains largely intact in the optical clearing procedure, information loss is avoided. Not only can PA imaging benefit from optical clearing, it can also be used to study the physiological effects induced by optical clearing. With enhanced penetration depth and resolution, PAM will become more valuable for structural, molecular, functional, and metabolic imaging.</p></body><back><ack id="S1"><p>The authors would like to thank Prof. James Ballard for manuscript editing. We also appreciate technical assistance and useful discussions from Jinyang Liang and Chi Zhang. This research was supported by the National Institutes of Health Grants DP1 EB016986 (NIH Director&#x02019;s Pioneer Award), R01 EB008085, R01 CA134539, U54 CA136398, R01 CA157277, and R01 CA159959. L.V.W. has a financial interest in Microphotoacoustics, Inc. and Endra, Inc., which, however, did not support this work.</p></ack><ref-list><ref id="R1"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>LV</given-names></name><name><surname>Hu</surname><given-names>S</given-names></name></person-group><article-title>Photoacoustic tomography: in vivo imaging from organelles to organs</article-title><source>Science</source><volume>335</volume><issue>6075</issue><fpage>1458</fpage><lpage>1462</lpage><year>2012</year><pub-id pub-id-type="pmid">22442475</pub-id></element-citation></ref><ref id="R2"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhou</surname><given-names>Y</given-names></name><name><surname>Zhang</surname><given-names>C</given-names></name><name><surname>Yao</surname><given-names>DK</given-names></name><name><surname>Wang</surname><given-names>LV</given-names></name></person-group><article-title>Photoacoustic microscopy of bilirubin in tissue phantoms</article-title><source>J Biomed Opt</source><volume>17</volume><issue>12</issue><fpage>126019</fpage><year>2012</year><pub-id pub-id-type="pmid">23235894</pub-id></element-citation></ref><ref id="R3"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chen</surname><given-names>SL</given-names></name><name><surname>Ling</surname><given-names>T</given-names></name><name><surname>Huang</surname><given-names>SW</given-names></name><name><surname>Won Baac</surname><given-names>H</given-names></name><name><surname>Guo</surname><given-names>LJ</given-names></name></person-group><article-title>Photoacoustic correlation spectroscopy and its application to low-speed flow measurement</article-title><source>Opt Lett</source><volume>35</volume><issue>8</issue><fpage>1200</fpage><lpage>1202</lpage><year>2010</year><pub-id pub-id-type="pmid">20410966</pub-id></element-citation></ref><ref id="R4"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yao</surname><given-names>J</given-names></name><name><surname>Wang</surname><given-names>LV</given-names></name></person-group><article-title>Photoacoustic tomography: fundamentals, advances and prospects</article-title><source>Contrast Media Mol Imag</source><volume>6</volume><issue>5</issue><fpage>332</fpage><lpage>345</lpage><year>2011</year></element-citation></ref><ref id="R5"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yao</surname><given-names>J</given-names></name><name><surname>Maslov</surname><given-names>KI</given-names></name><name><surname>Shi</surname><given-names>Y</given-names></name><name><surname>Taber</surname><given-names>LA</given-names></name><name><surname>Wang</surname><given-names>LV</given-names></name></person-group><article-title>In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth</article-title><source>Opt Lett</source><volume>35</volume><issue>9</issue><fpage>1419</fpage><lpage>142</lpage><year>2010</year><pub-id pub-id-type="pmid">20436589</pub-id></element-citation></ref><ref id="R6"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yao</surname><given-names>J</given-names></name><name><surname>Maslov</surname><given-names>KI</given-names></name><name><surname>Zhang</surname><given-names>Y</given-names></name><name><surname>Xia</surname><given-names>Y</given-names></name><name><surname>Wang</surname><given-names>LV</given-names></name></person-group><article-title>Label-free oxygen-metabolic photoacoustic microscopy in vivo</article-title><source>J Biomed Opt</source><volume>16</volume><issue>7</issue><fpage>076003</fpage><year>2011</year><pub-id pub-id-type="pmid">21806264</pub-id></element-citation></ref><ref id="R7"><label>7</label><element-citation publication-type="book"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>LV</given-names></name><name><surname>Wu</surname><given-names>H</given-names></name></person-group><source>Biomedical Optics: Principles and Imaging</source><publisher-name>Wiley</publisher-name><publisher-loc>Hoboken, NJ</publisher-loc><year>2007</year></element-citation></ref><ref id="R8"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname><given-names>D</given-names></name><name><surname>Larin</surname><given-names>KV</given-names></name><name><surname>Luo</surname><given-names>Q</given-names></name><name><surname>Tuchin</surname><given-names>VV</given-names></name></person-group><article-title>Recent progress in tissue optical clearing</article-title><source>Laser &#x00026; Photon Rev</source><fpage>1</fpage><lpage>26</lpage><year>2013</year></element-citation></ref><ref id="R9"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kinnunen</surname><given-names>M</given-names></name><name><surname>Myllyl&#x000e4;</surname><given-names>R</given-names></name></person-group><article-title>Effect of glucose on photoacoustic signals at the wavelengths of 1064 and 532 nm in pig blood and intralipid</article-title><source>J Phys D: Appl Phys</source><volume>38</volume><issue>15</issue><fpage>2654</fpage><year>2005</year></element-citation></ref><ref id="R10"><label>10</label><element-citation publication-type="book"><person-group person-group-type="author"><name><surname>Myllyl&#x000e4;</surname><given-names>R</given-names></name><name><surname>Zhao</surname><given-names>Z</given-names></name><name><surname>Kinnunen</surname><given-names>M</given-names></name></person-group><person-group person-group-type="editor"><name><surname>Tuchin</surname><given-names>Valery V</given-names></name></person-group><article-title>Pulsed photoacoustic techniques and glucose determination in human blood and tissue</article-title><source>Handbook of Optical Sensing of Glucose in Biological Fluids and Tissues</source><publisher-name>Taylor &#x00026; Francis</publisher-name><year>2008</year><fpage>419</fpage><lpage>455</lpage></element-citation></ref><ref id="R11"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tuchin</surname><given-names>VV</given-names></name></person-group><article-title>Optical clearing of tissue and blood using immersion method</article-title><source>J Phys D</source><volume>38</volume><fpage>2497</fpage><lpage>2518</lpage><year>2005</year></element-citation></ref><ref id="R12"><label>12</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wen</surname><given-names>X</given-names></name><name><surname>Mao</surname><given-names>Z</given-names></name><name><surname>Han</surname><given-names>Z</given-names></name><name><surname>Tuchin</surname><given-names>VV</given-names></name><name><surname>Zhu</surname><given-names>D</given-names></name></person-group><article-title>In vivo skin optical clearing by glycerol solutions: mechanism</article-title><source>J Biophoton</source><volume>3</volume><issue>12</issue><fpage>44</fpage><lpage>52</lpage><year>2010</year></element-citation></ref><ref id="R13"><label>13</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Vargas</surname><given-names>G</given-names></name><name><surname>Readinger</surname><given-names>A</given-names></name><name><surname>Dozier</surname><given-names>SS</given-names></name><name><surname>Welch</surname><given-names>AJ</given-names></name></person-group><article-title>Morphological Changes in Blood Vessels Produced by Hyperosmotic Agents and Measured by Optical Coherence Tomography</article-title><source>Photochem and Photobiol</source><volume>77</volume><fpage>541</fpage><lpage>549</lpage><year>2003</year></element-citation></ref><ref id="R14"><label>14</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname><given-names>D</given-names></name><name><surname>Zhang</surname><given-names>J</given-names></name><name><surname>Cui</surname><given-names>H</given-names></name><name><surname>Mao</surname><given-names>Z</given-names></name><name><surname>Li</surname><given-names>P</given-names></name><name><surname>Luo</surname><given-names>Q</given-names></name></person-group><article-title>Short-term and long-term effects of optical clearing agents on blood vessels in chick chorioallantoic membrane</article-title><source>J Biomed Opt</source><volume>13</volume><issue>2</issue><fpage>021106</fpage><year>2008</year><pub-id pub-id-type="pmid">18465955</pub-id></element-citation></ref><ref id="R15"><label>15</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zhu</surname><given-names>D</given-names></name><name><surname>Wang</surname><given-names>J</given-names></name><name><surname>Zhi</surname><given-names>Z</given-names></name><name><surname>Wen</surname><given-names>X</given-names></name><name><surname>Luo</surname><given-names>Q</given-names></name></person-group><article-title>Imaging dermal blood flow through the intact rat skin with an optical clearing method</article-title><source>J Biomed Opt</source><volume>15</volume><issue>2</issue><fpage>026008</fpage><year>2010</year><pub-id pub-id-type="pmid">20459253</pub-id></element-citation></ref><ref id="R16"><label>16</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wang</surname><given-names>J</given-names></name><name><surname>Shi</surname><given-names>R</given-names></name><name><surname>Zhu</surname><given-names>D</given-names></name></person-group><article-title>Switchable skin window induced by optical clearing method for dermal blood flow imaging</article-title><source>J Biomed Opt</source><volume>18</volume><issue>6</issue><fpage>061209</fpage><year>2012</year><pub-id pub-id-type="pmid">23154794</pub-id></element-citation></ref></ref-list></back><floats-group><fig id="F1" orientation="portrait" position="float"><label>Fig. 1</label><caption><p>System schematic used in the experiment. CorL, correction lens; OL, objective lens; RAP, right-angle prism; RhP, rhomboid prism; SOL, silicone oil layer; UT, ultrasonic transducer.</p></caption><graphic xlink:href="nihms500772f1"/></fig><fig id="F2" orientation="portrait" position="float"><label>Fig. 2</label><caption><p>Optical clearing aided PAM of a coin covered by mouse skin. (a) Photograph of the one cent coin used in the experiment. (b)&#x02013;(d) PA images of the coin at different times during optical clearing. (e) Time course of the PA amplitude averaged over the whole image during optical clearing. The higher PA amplitude indicates that the optical clearing increased penetration depth.</p></caption><graphic xlink:href="nihms500772f2"/></fig><fig id="F3" orientation="portrait" position="float"><label>Fig. 3</label><caption><p>In vivo PAM of mouse scalp facilitated by optical clearing. (a) PAM image before optical clearing. (b) PAM image with capillaries after optical clearing. (c) PAM image with parts of capillary layer digitally removed after optical clearing. (d&#x02013;f) PA amplitude along the red dashed line in (a&#x02013;c). Maximum-amplitude-projection image along the y axis (g) before and (h) after optical clearing. (i) PA amplitude averaged along the x direction of (g) (blue line) and (h) (red dashed line). 3D PA image (j) (Media 1) before and (k) (Media 2) after optical clearing.</p></caption><graphic xlink:href="nihms500772f3"/></fig><fig id="F4" orientation="portrait" position="float"><label>Fig. 4</label><caption><p>Optical clearing reveals more capillaries. (a&#x02013;b) Close-ups of PAM images in the red dashed boxes in <xref rid="F3" ref-type="fig">Figs. 3(a&#x02013;b)</xref>. (c&#x02013;d) PA amplitudes along the red dashed lines in (a&#x02013;b).</p></caption><graphic xlink:href="nihms500772f4"/></fig><fig id="F5" orientation="portrait" position="float"><label>Fig. 5</label><caption><p>Optical clearing improves the lateral resolution for deep vessels. (a) Close-up of PAM image in the green dashed box in <xref rid="F3" ref-type="fig">Fig. 3(a)</xref>. (b) Close-up of PAM image in the green dashed box in <xref rid="F3" ref-type="fig">Fig. 3(c)</xref>. (c&#x02013;d) PA amplitudes along the red dashed lines in (a&#x02013;b). (e) Combined curves in (c) and (d) after normalization.</p></caption><graphic xlink:href="nihms500772f5"/></fig></floats-group></article>