<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101628372</journal-id><journal-id journal-id-type="pubmed-jr-id">42454</journal-id><journal-id journal-id-type="nlm-ta">IEEE Trans Hum Mach Syst</journal-id><journal-id journal-id-type="iso-abbrev">IEEE Trans Hum Mach Syst</journal-id><journal-title-group><journal-title>IEEE transactions on human-machine systems</journal-title></journal-title-group><issn pub-type="ppub">2168-2291</issn><issn pub-type="epub">2168-2305</issn></journal-meta><article-meta><article-id pub-id-type="pmid">40160534</article-id><article-id pub-id-type="pmc">11951292</article-id><article-id pub-id-type="doi">10.1109/thms.2025.3539187</article-id><article-id pub-id-type="manuscript">HHSPA2061581</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>A Single-Camera Method for Estimating Lift Asymmetry Angles Using Deep Learning Computer Vision Algorithms</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Lou</surname><given-names>Zhengyang</given-names></name><aff id="A1">Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA</aff></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0009-0003-4111-766X</contrib-id><name><surname>Zhan</surname><given-names>Zitong</given-names></name><aff id="A2">Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA. He is now with the Department of Computer Science and Engineering, University at Buffalo, Buffalo, NY 14260 USA</aff></contrib><contrib contrib-type="author"><name><surname>Xu</surname><given-names>Huan</given-names></name><aff id="A3">Department of Electrical and Computer Engineering University of Wisconsin-Madison, Madison, WI 53706 USA. He is now with the School of Computer Science, Georgia Institute of Technology, Atlanta, GA 30332 USA</aff></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0003-4173-9453</contrib-id><name><surname>Li</surname><given-names>Yin</given-names></name><aff id="A4">Department of Biostatistics &#x00026; Medical Informatics and Department of Computer Sciences, University of Wisconsin-Madison, Madison, WI 53706 USA</aff></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0003-3427-0677</contrib-id><name><surname>Hu</surname><given-names>Yu Hen</given-names></name><role>Life Fellow, IEEE</role><aff id="A5">Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA</aff></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0002-8291-9111</contrib-id><name><surname>Lu</surname><given-names>Ming-Lun</given-names></name><aff id="A6">CDC National Institute for Occupational Safety and Health, Division of Field Studies and Engineering, Cincinnati, OH 45226 USA</aff></contrib><contrib contrib-type="author"><name><surname>Werren</surname><given-names>Dwight M.</given-names></name><aff id="A7">CDC National Institute for Occupational Safety and Health, Taft Laboratories, Cincinnati, OH 45226 USA</aff></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0002-7973-0641</contrib-id><name><surname>Radwin</surname><given-names>Robert G.</given-names></name><role>Senior Member, IEEE</role><aff id="A8">Department of Industrial and Systems Engineering and the Department of Biomedical Engineering, University of Wisconsin-Madison, Madison, WI 53706 USA</aff></contrib></contrib-group><author-notes><corresp id="CR1">Corresponding author: Robert G. Radwin. <email>rradwin@wisc.edu</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>12</day><month>3</month><year>2025</year></pub-date><pub-date pub-type="ppub"><month>4</month><year>2025</year></pub-date><pub-date pub-type="pmc-release"><day>01</day><month>4</month><year>2025</year></pub-date><volume>55</volume><issue>2</issue><fpage>309</fpage><lpage>314</lpage><permissions><license><license-p>Personal use is permitted, but republication/redistribution requires IEEE permission. See <ext-link ext-link-type="uri" xlink:href="https://www.ieee.org/publications/rights/index.html">https://www.ieee.org/publications/rights/index.html</ext-link> for more information.</license-p></license></permissions><abstract id="ABS1"><p id="P1">A computer vision (CV) method to automatically measure the revised NIOSH lifting equation asymmetry angle (<italic toggle="yes">A</italic>) from a single camera is described and tested. A laboratory study involving ten participants performing various lifts was used to estimate <italic toggle="yes">A</italic> in comparison to ground truth joint coordinates obtained using 3-D motion capture (MoCap). To address challenges, such as obstructed views and limitations in camera placement in real-world scenarios, the CV method utilized video-derived coordinates from a selected set of landmarks. A 2-D pose estimator (HR-Net) detected landmark coordinates in each video frame, and a 3-D algorithm (VideoPose3D) estimated the depth of each 2-D landmark by analyzing its trajectories. The mean absolute precision error for the CV method, compared to MoCap measurements using the same subset of landmarks for estimating <italic toggle="yes">A</italic>, was 6.25&#x000b0; (SD = 10.19&#x000b0;, N = 360). The mean absolute accuracy error of the CV method, compared against conventional MoCap landmark markers was 9.45&#x000b0; (SD = 14.01&#x000b0;, <italic toggle="yes">N</italic> = 360).</p></abstract><kwd-group><kwd>Computer vision (CV)</kwd><kwd>low back pain</kwd><kwd>manual materials handling</kwd><kwd>NIOSH lifting equation</kwd><kwd>risk assessment</kwd></kwd-group></article-meta></front><body><sec id="S1"><label>I.</label><title>I<sc>ntroduction</sc></title><p id="P2">The revised NIOSH lifting equation (RNLE) is a widely employed tool for assessing ergonomic risks associated with manual lifts [<xref rid="R1" ref-type="bibr">1</xref>], [<xref rid="R2" ref-type="bibr">2</xref>]. It has been validated through numerous epidemiological studies, demonstrating its effectiveness in predicting various outcomes related to low back pain [<xref rid="R3" ref-type="bibr">3</xref>]. Incorporated into ISO standard 11228-1 and numerous industry consensus standards [<xref rid="R4" ref-type="bibr">4</xref>], the RNLE calculates the recommended weight limit (RWL) based on a load constant and six multipliers derived from several task variables, including horizontal and vertical distances between hands and body, lift asymmetry angle (<italic toggle="yes">A</italic>), load displacement, hand coupling, and lifting task frequency [<xref rid="R1" ref-type="bibr">1</xref>].</p><p id="P3">Nonetheless, manual measurement of these task variables is arduous and time-consuming, particularly when multiple tasks are involved during a shift [<xref rid="R5" ref-type="bibr">5</xref>], [<xref rid="R6" ref-type="bibr">6</xref>]. To address this, on-screen posture specifications from video recordings have been utilized to determine posture related RNLE task variables, such as hand locations and lift asymmetry angle. That method took approximately 200 seconds per posture specification [<xref rid="R6" ref-type="bibr">6</xref>]. Additionally, challenges such as load projection and workplace obstructions further complicate manual measurements of the asymmetric angle.</p><p id="P4">Measuring <italic toggle="yes">A</italic> presents the greatest challenge among the RNLE task variables due to the intricate identification of the asymmetry line and sagittal line during a lift [<xref rid="R5" ref-type="bibr">5</xref>]. The angle is crucial for determining the asymmetry multiplier (AM)
<disp-formula id="FD1">
<label>(1)</label><mml:math id="M1" display="block"><mml:mrow><mml:mtext>AM</mml:mtext><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo>&#x02212;</mml:mo><mml:mn>.0032</mml:mn><mml:mi>A</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:math>
</disp-formula></p><p id="P5">Angle <italic toggle="yes">A</italic> quantifies the displacement of a lifted object from the worker&#x02019;s mid-sagittal plane at the start or end of a lift, measured in degrees at both points. Specifically applicable to asymmetric lifts at the origin or destination (see <xref rid="F1" ref-type="fig">Fig. 1</xref>), <italic toggle="yes">A</italic> is operationally defined as the angle between the asymmetry line and the mid-sagittal line without any pivoting or stepping [<xref rid="R1" ref-type="bibr">1</xref>]. Given that the mid-sagittal plane is referenced to the neutral anatomical position rather than the actual position assumed during the lift&#x02019;s origin or destination, this measurement necessitates identifying the sagittal plane while the body deviates from neutral.</p><p id="P6">Researchers, driven by the challenges of manual measurement of the RNLE, have explored automated solutions utilizing sensors like 3-D motion capture (MoCap) or inertial measurement units (IMUs) to extract RNLE parameters. Shammaa et al. [<xref rid="R7" ref-type="bibr">7</xref>] outlined a method for measuring RNLE parameters, including horizontal location (<italic toggle="yes">H</italic>), vertical location (<italic toggle="yes">V</italic>), vertical travel distance (<italic toggle="yes">D</italic>), and <italic toggle="yes">A</italic>, by calculating <italic toggle="yes">A</italic> from MoCap marker positions on the body&#x02019;s surface. This method involves placing markers on both sides of the ankles to establish the mid-sagittal plane, assuming aligned ankles and neutral foot positions, which may not always hold true. While highly precise, 3-D MoCap systems are impractical for field use due to their reliance on multiple cameras and limited visibility in obstructed workplace environments.</p><p id="P7">With the improvement in accuracy and reliability of IMU sensors [<xref rid="R8" ref-type="bibr">8</xref>], [<xref rid="R9" ref-type="bibr">9</xref>], [<xref rid="R10" ref-type="bibr">10</xref>], their potential for estimating RNLE parameters were studied. Unlike MoCap systems, IMU sensors offer simplicity and freedom from visual obstructions. However, they have several drawbacks; they are invasive, must be attached to the body, possibly interfere with worker movements, and their accuracy may degrade over time from drift [<xref rid="R11" ref-type="bibr">11</xref>].</p><p id="P8">Computer vision (CV) provides a practical, non-invasive method for automated and precise lifting monitoring solely using video data. In [<xref rid="R12" ref-type="bibr">12</xref>], a modified twin Gaussian algorithm [<xref rid="R13" ref-type="bibr">13</xref>] was employed to estimate 3-D postures and joint kinematics. Mehrizi et al. [<xref rid="R14" ref-type="bibr">14</xref>] investigated 3-D posture estimation feasibility using deep models and a multi-view setup, adapting a classic 2-D human pose stacked hourglass network [<xref rid="R15" ref-type="bibr">15</xref>].</p><p id="P9">In our previous work [<xref rid="R16" ref-type="bibr">16</xref>], we demonstrated the feasibility of extracting RNLE parameters&#x02014;such as vertical lifting heights, horizontal distances, and lifting frequencies and automatically detecting lift origin and destination using a single video camera. However, the method for estimating <italic toggle="yes">A</italic> required multiple cameras, which presents challenges in calibration and practical implementation in the workplace due to space constraints and computational complexity. To address these limitations, our current study presents a novel approach to estimate the RNLE asymmetry angle <italic toggle="yes">A</italic>, using only a single camera.</p><p id="P10">This new method leverages deep-learning-based single-view 3-D human pose estimation algorithms [<xref rid="R17" ref-type="bibr">17</xref>], [<xref rid="R18" ref-type="bibr">18</xref>], [<xref rid="R19" ref-type="bibr">19</xref>], [<xref rid="R20" ref-type="bibr">20</xref>] to predict 3D skeletal joint coordinates and estimate asymmetry angle <italic toggle="yes">A</italic> based on video from a monocular RGB camera. These 3-D human pose estimation algorithms have shown high accuracy in standard CV datasets like Human3.6M [<xref rid="R21" ref-type="bibr">21</xref>]. A recent work also studied their application in ergonomic assessments [<xref rid="R40" ref-type="bibr">40</xref>]. However, their suitability for automatic asymmetry angle estimation remains unexplored.</p><p id="P11">Our method considers alternative, more visible body landmarks for estimating the sagittal plane, diverging from the ankle markers used in previous research [<xref rid="R7" ref-type="bibr">7</xref>], which may not consistently measure the midsagittal plane and are impractical for CV field application. We compare the single-camera CV method for estimating the asymmetry angle against asymmetry angles measured using multicamera 3-D MoCap data obtained simultaneously as ground truth measures [<xref rid="R8" ref-type="bibr">8</xref>], [<xref rid="R9" ref-type="bibr">9</xref>], assessing the accuracy of our approach relative to conventional laboratory methods. Additionally, we compare the precision of CV-measured asymmetry angles against those computed using the same alternative landmarks measured by MoCap.</p></sec><sec id="S2"><label>II.</label><title>M<sc>ethods</sc></title><sec id="S3"><label>A.</label><title>Asymmetry Angle Using Conventional 3-D MoCap Joint Coordinates (A<sub>MoCap</sub>)</title><p id="P12">The asymmetry angle is the angle between the sagittal line and the asymmetry line (see <xref rid="F1" ref-type="fig">Fig. 1</xref>), measured at both the start and end of a lift [<xref rid="R1" ref-type="bibr">1</xref>]. It is assumed that at the start, the body aligns with the asymmetry line, and the feet remain stationary before the torso rotates. Similarly, at the end, the body aligns with the asymmetry line, and the feet remain stationary before releasing the object. The mid-sagittal line is defined as the line passing through the midpoint between the inner ankle bones (considered the body center) and lying in the mid-sagittal plane, based on the neutral body position in the <italic toggle="yes">applications manual for the</italic> RNLE [<xref rid="R1" ref-type="bibr">1</xref>] for the ease of operational measurements. Trunk rotation (lift asymmetry) occurs after lifting the object with both hands. The asymmetry line, defining the asymmetry plane, is determined by projecting the object&#x02019;s center on the floor (point of projection) to the body center.</p><p id="P13">Calculation of the asymmetry angle (<italic toggle="yes">A</italic>) requires determining the body center (<italic toggle="yes">O</italic>), the point of projection (<italic toggle="yes">P</italic>), and a point (<italic toggle="yes">Q</italic>) as shown in <xref rid="F1" ref-type="fig">Fig. 1</xref>. According to [<xref rid="R6" ref-type="bibr">6</xref>], the <italic toggle="yes">x</italic>&#x02013;<italic toggle="yes">y</italic> coordinates of the body center <italic toggle="yes">O</italic> were estimated as the mid-point between the two ankle joints, and the point of projection <italic toggle="yes">P</italic> was estimated using the <italic toggle="yes">x</italic>&#x02013;<italic toggle="yes">y</italic> coordinates of the mid-point of the knuckles of both hands. A second point on the mid-sagittal line (point <italic toggle="yes">Q</italic>) is estimated as the mid-point of the second distal phalanges (second toes) of both feet of the subject. Given the x-y coordinates of <italic toggle="yes">O</italic>, <italic toggle="yes">P</italic> and <italic toggle="yes">Q</italic>, <italic toggle="yes">A</italic> may be computed using the following formula:
<disp-formula id="FD2">
<label>(2)</label><mml:math id="M2" display="block"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mrow><mml:mtext>MoCap</mml:mtext></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mrow><mml:mi>cos</mml:mi></mml:mrow><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:msup><mml:mfrac><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>P</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover><mml:mo>&#x022c5;</mml:mo><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>Q</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mrow><mml:mrow><mml:mo>&#x02016;</mml:mo><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>P</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mo>&#x02016;</mml:mo></mml:mrow><mml:mo>&#x022c5;</mml:mo><mml:mrow><mml:mo>&#x02016;</mml:mo><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>Q</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mo>&#x02016;</mml:mo></mml:mrow></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M3" display="inline"><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>P</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>Q</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow></mml:math></inline-formula> are two dimensional vectors in the <italic toggle="yes">x</italic>&#x02013;<italic toggle="yes">y</italic> plane from body center <italic toggle="yes">O</italic> to <italic toggle="yes">P</italic> and <italic toggle="yes">Q</italic>, respectively. <inline-formula><mml:math id="M5" display="inline"><mml:mrow><mml:mrow><mml:mo>&#x02016;</mml:mo><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>P</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mo>&#x02016;</mml:mo></mml:mrow></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M6" display="inline"><mml:mrow><mml:mrow><mml:mo>&#x02016;</mml:mo><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>O</mml:mi><mml:mi>Q</mml:mi></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mo>&#x02016;</mml:mo></mml:mrow></mml:mrow></mml:math></inline-formula> are the magnitudes of the corresponding vectors.</p></sec><sec id="S4"><label>B.</label><title>Asymmetry Angle Using Computer Vision Joint Coordinates (A<sub>CV</sub>)</title><p id="P14">We redefine the sagittal plane as the vertical plane intersecting the midpoint between hip landmarks instead of the traditional ankle joints. From an ergonomics perspective, the rationale is that the sagittal plane is perpendicular to the hips when the upright body is in the neutral anatomical position and these landmarks are not affected by rotation of the feet. For CV applications, hips are preferable to ankles due to their more reliable estimations in the field. This is because ankles, as extremity joints, present fewer constraints and are therefore harder to estimate [<xref rid="R38" ref-type="bibr">38</xref>], and are more prone to occlusion, which degrades accuracy [<xref rid="R39" ref-type="bibr">39</xref>]. Additionally, we opt for wrist joints over knuckles, as they are anatomically close and commonly detected by CV algorithms [<xref rid="R21" ref-type="bibr">21</xref>].</p><p id="P15">A skeletal joint body model of a worker performing a lift is shown on the left-hand side of <xref rid="F2" ref-type="fig">Fig. 2</xref>. Denote the projection of the 3-D coordinates of the hip landmarks on the floor as <italic toggle="yes">H<sub>L</sub></italic> and <italic toggle="yes">H<sub>R</sub></italic>, the projection of the 3-D coordinates of the wrist landmarks on the floor as <italic toggle="yes">W<sub>L</sub></italic> and <italic toggle="yes">W<sub>R</sub></italic> as shown in the right side of the <xref rid="F2" ref-type="fig">Fig. 2</xref>. The body center here is denoted by <italic toggle="yes">m<sub>h</sub></italic>, the point of projection is now denoted by <italic toggle="yes">m<sub>c</sub></italic>. A unit-vector <inline-formula><mml:math id="M7" display="inline"><mml:mrow><mml:mover accent="true"><mml:msub><mml:mrow><mml:mi>v</mml:mi></mml:mrow><mml:mi>s</mml:mi></mml:msub><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow></mml:math></inline-formula> that is perpendicular to the line segment <inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mover accent="true"><mml:mrow><mml:msub><mml:mi>H</mml:mi><mml:mi>R</mml:mi></mml:msub><mml:msub><mml:mi>H</mml:mi><mml:mi>L</mml:mi></mml:msub></mml:mrow><mml:mo stretchy="true">&#x000af;</mml:mo></mml:mover></mml:mrow></mml:math></inline-formula> and originates from <italic toggle="yes">m<sub>h</sub></italic> gives the direction of the mid-sagittal line. Similarly, a unit-vector <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mover accent="true"><mml:mrow><mml:msub><mml:mi>v</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow></mml:math></inline-formula> from <italic toggle="yes">m<sub>h</sub></italic> to <italic toggle="yes">m<sub>c</sub></italic>gives the direction of the asymmetry line. Then, the CV angle of asymmetry (<italic toggle="yes">A<sub>CV</sub></italic> ) can be estimated as the arc cosine of the inner product of these two unit-vectors
<disp-formula id="FD3">
<label>(3)</label><mml:math id="M10" display="block"><mml:mrow><mml:msub><mml:mi>A</mml:mi><mml:mrow><mml:mtext>CV</mml:mtext></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msup><mml:mrow><mml:mi>cos</mml:mi></mml:mrow><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:msup><mml:mrow><mml:mo>(</mml:mo><mml:mrow><mml:msubsup><mml:mrow><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mi>a</mml:mi><mml:mi>T</mml:mi></mml:msubsup><mml:msub><mml:mrow><mml:mover accent="true"><mml:mi>v</mml:mi><mml:mo stretchy="true">&#x02192;</mml:mo></mml:mover></mml:mrow><mml:mi>s</mml:mi></mml:msub></mml:mrow><mml:mo>)</mml:mo></mml:mrow><mml:mo>.</mml:mo></mml:mrow></mml:math>
</disp-formula></p><p id="P16">Given a single view video, the 3-D coordinates will need to be estimated from the video using another approach, which will be described in <xref rid="S6" ref-type="sec">Section II-D</xref>.</p></sec><sec id="S5"><label>C.</label><title>Asymmetry Angle Using 3-D MoCap Joint Coordinates and CV Landmarks (&#x00100;<sub>CV</sub>)</title><p id="P17">The same landmarks used for <italic toggle="yes">A</italic><sub>CV</sub> were also calculated using the corresponding 3-D MoCap measurements. We term this quantity <italic toggle="yes">&#x00100;</italic><sub>CV</sub>. Specifically, <italic toggle="yes">&#x00100;<sub>CV</sub></italic> was calculated using the hip landmarks on the floor as <italic toggle="yes">H<sub>L</sub></italic> and <italic toggle="yes">H<sub>R</sub></italic>, the projection of the 3-D coordinates of the wrist landmarks on the floor as <italic toggle="yes">W<sub>L</sub></italic> and <italic toggle="yes">W<sub>R</sub></italic> measured from the MoCap system.</p></sec><sec id="S6"><label>D.</label><title>Deep-Learning-Based 3-D Landmark Estimation</title><p id="P18">CV algorithms enable automatic estimation of a 3-D human skeleton from monocular video. Initially, body location is detected in each video frame using a human detector, resulting in a bounding box of the body region [<xref rid="R24" ref-type="bibr">24</xref>]. Next, a 2-D pose estimator, HR-Net, processes each cropped human image to estimate 2-D coordinates for 17 skeletal joints [<xref rid="R25" ref-type="bibr">25</xref>]. Tracking then links 2-D landmarks belonging to the same individual across frames [<xref rid="R26" ref-type="bibr">26</xref>]. Within a local window around the lifting frame, VideoPose3D [<xref rid="R20" ref-type="bibr">20</xref>], a 3-D pose estimator, processes tracked 2-D landmarks to estimate the relative depth of each 3-D landmark for the lifting video frame, as depicted in <xref rid="F3" ref-type="fig">Fig. 3</xref>.</p></sec><sec id="S7"><label>E.</label><title>Perspective-n-Point (PnP) for Coordinate Alignment and Refinement of the Model</title><p id="P19">The VideoPose3D algorithm [<xref rid="R20" ref-type="bibr">20</xref>] needs to be fine-tuned with domain-specific data to enhance its performance [<xref rid="R14" ref-type="bibr">14</xref>], [<xref rid="R15" ref-type="bibr">15</xref>], [<xref rid="R27" ref-type="bibr">27</xref>]. This dataset, described in detail in the subsequent section, comprises video clips of subjects performing lifting tasks and corresponding 3-D joint coordinates measured using MoCap. Initially, HR-Net is employed on each frame to estimate the 2-D poses (joint locations). Then, the pre-trained VideoPose3D model is refined using HR-net estimated 2-D poses as the input and the corresponding MoCap-derived 3-D joint locations as targets.</p><p id="P20">Since MoCap-derived 3-D landmarks are in a different coordinate system from that of the video camera, alignment is necessary using a PnP algorithm [<xref rid="R23" ref-type="bibr">23</xref>]. The PnP algorithm estimates the camera pose, namely the extrinsic parameters of the video camera, using the set of 2-D and corresponding 3-D joint coordinates. Then, the MoCap-measured 3-D joint positions are transformed into the camera coordinate system for refinement training. To validate the alignment process, MoCap-derived 3-D joint coordinates are back-projected onto the video camera&#x02019;s image plane using the estimated camera pose. The normalized reprojection error, indicating the difference between back projected 2-D joint coordinates and those estimated using HRNet, divided by the diagonal length of video frames, is 0.02. Given a video frame resolution of 640 by 480 pixels, the average back projection error is approximately 16 pixels. During refinement of the VideoPose3D model, we employed leave-one-subject-out cross-validation (see <xref rid="S9" ref-type="sec">Section II-G</xref>.) to mitigate concerns of overfitting. Hyperparameters selected for fine-tuning include a learning rate of 0.001, batch size of 64, training epochs of 20, and the AMSGrad optimizer [<xref rid="R28" ref-type="bibr">28</xref>].</p></sec><sec id="S8"><label>F.</label><title>Data Acquisition</title><p id="P21">The video data utilized in this article originated from a previous NIOSH study conducted in Cincinnati, Ohio [<xref rid="R8" ref-type="bibr">8</xref>]. Ten NIOSH associates participated in this prior study, performing 12 lifting tasks under IRB approval, with informed consent obtained from each participant. Hand locations for each lifting task were adjusted based on the 12 lifting zones defined by the American conference of governmental industrial hygienists (ACGIH) threshold limit value (TLV) for lifting to encompass a wide range of lifting motions [<xref rid="R29" ref-type="bibr">29</xref>]. Each subject repeated each lifting task three times, resulting in a total of 36 randomly assigned lifting trials completed in one session. During each trial, subjects walked from a starting point to one of 12 marked locations, lifted a wire grid frame weighing 0.45 kg, turned around, walked to shelf height to drop off the frame, and returned to the finish line. The lightweight frame ensured clear visibility of MoCap markers.</p><p id="P22">Among the 360 video recordings, 147 exhibited trunk rotation before stepping or significant hip movement, while the remaining videos had near-zero asymmetry angles A. These videos were used for analysis as a control condition for zero asymmetry angles. Asymmetry angle A was measured for three types of lifts (symmetric, asymmetric toward the camera, and asymmetric away from the camera) after lift initiation (BOL), as depicted in <xref rid="F4" ref-type="fig">Fig. 4</xref>.</p><p id="P23">Ethical approval was obtained from the appropriate local ethics committee or Institutional Review Board (University of Wisconsin-Madison Federal Wide Assurance no. #FWA00005399), protocol number 2016-0297-CR006, and informed consent has been obtained.</p></sec><sec id="S9"><label>G.</label><title>Evaluation With Cross-Validation</title><p id="P24">The machine-learning algorithm underwent leave-one-subject-out cross-validation to evaluate its accuracy and robustness while mitigating potential overfitting [<xref rid="R27" ref-type="bibr">27</xref>]. The dataset was divided into ten subsets, and this process was repeated ten times. In each iteration, one subject was designated as the test set, and the remaining nine subjects constituted the training set. This led to the creation of ten models, each trained and evaluated using a different test set. The overall performance, measured by angle estimation error in degrees, was averaged across these ten models.</p><p id="P25">Evaluation metrics included the mean absolute error and standard deviation of the estimated asymmetry angle compared to ground truth MoCap values [<xref rid="R8" ref-type="bibr">8</xref>], [<xref rid="R9" ref-type="bibr">9</xref>]. To complement the mean absolute error, a threshold accuracy with a 15&#x000b0; error interval was introduced (see <xref rid="S11" ref-type="sec">Section III-A</xref>), following the RNLE Applications Manual [<xref rid="R22" ref-type="bibr">22</xref>]. Precision was assessed by comparing the 2-D CV-measured asymmetry angle (<italic toggle="yes">A</italic><sub>CV</sub>) against the asymmetry angle computed using the same MoCap-measured landmarks (<italic toggle="yes">&#x00100;<sub>CV</sub></italic>). Accuracy was evaluated by comparing the 2-D CV-measured asymmetry angle (<italic toggle="yes">A</italic><sub>CV</sub>) against the conventional 3-D MoCap-derived angle (<italic toggle="yes">A</italic><sub>MoCap</sub>).</p></sec></sec><sec id="S10"><label>III.</label><title>R<sub>esults</sub></title><sec id="S11"><label>A.</label><title>Hip-to-Hip Error (A<sub>CV</sub> &#x02013; &#x00100;<sub>CV</sub>)</title><p id="P26">The CV-measured asymmetry angle (<italic toggle="yes">A</italic><sub>CV</sub>) was compared against the asymmetry angle, computed using the same landmarks measured by MoCap (<italic toggle="yes">&#x00100;<sub>CV</sub></italic>). We term this hip-to-hip error as both used hip joints. The overall mean absolute angular error was 6.25&#x000b0; (SD = 10.19&#x000b0;). Across all subjects, the minimum mean error was 4.58&#x000b0; (SD = 5.86&#x000b0;) and the maximum mean error was 8.59&#x000b0; (SD = 11.28&#x000b0;).</p><p id="P27">From (<xref rid="FD1" ref-type="disp-formula">1</xref>), a 15&#x000b0; increment of A results in a 5% reduction of AM and hence a 5% change in RWL. We consider less than a 5% change in the RWL within the practical limits of precision of any of the variables included in the RNLE. Consequently, we evaluated the percentage of samples whose absolute error was less than 15&#x000b0;. The results showed that 91% of samples had an error of less than 15&#x000b0; across ten subjects.</p><p id="P28">A histogram across all subjects, for the number of estimated hip-to-hip error cases plotted against error range, is shown in <xref rid="F5" ref-type="fig">Fig. 5</xref>. The histogram confirmed that most of the errors were small and within the range of [&#x02212;15&#x000b0;, 15&#x000b0;] (91%), yet had a few outliers having errors as large as &#x02212;60&#x000b0;. We summarize the percentiles of precision error above specific thresholds in <xref rid="T1" ref-type="table">Table I</xref> using a 15&#x000b0; interval following the RNLE guidelines. The percentiles for errors beyond 30&#x000b0; and 45&#x000b0; were 3.1% and 1.1%, respectively.</p><p id="P29">As shown in <xref rid="F4" ref-type="fig">Fig. 4</xref>, there were three types of lifts: symmetric lift (SL); turn toward the camera (TT); and turn away from the camera (TA). The mean absolute angular error and percent within 15&#x000b0; precision and percent within 30&#x000b0; precision for each type of lift are summarized in <xref rid="T2" ref-type="table">Table II</xref>. In state-of-the-art 2-D pose estimation algorithms, the 2-D coordinates of joints that are not observed directly are often estimated using prior information, leading to lower accuracy of the 2-D body joint positions. This leads to inaccurate 3-D body joint position estimates and hence higher angle estimation error. This explains why in <xref rid="T2" ref-type="table">Table II</xref>, the &#x0201c;turn away&#x0201d; lift scenario exhibits higher error rate compared to the SL and TT scenarios.</p></sec><sec id="S12"><label>B.</label><title>Hip-to-Ankle Error (A<sub>CV</sub> &#x02013; A<sub>MoCap</sub>)</title><p id="P30">The CV measured asymmetry angle <italic toggle="yes">A</italic><sub>CV</sub> was further compared to the conventional 3-D MoCap derived angle (<italic toggle="yes">A</italic><sub>MoCap</sub>). We term this quantity hip-to-ankle error as <italic toggle="yes">A</italic><sub>CV</sub> used hip while <italic toggle="yes">A</italic><sub>MoCap</sub> used ankles. The overall mean absolute accuracy error was 9.45&#x000b0; (SD = 14.01&#x000b0;). Across all subjects, the minimum mean error was 5.31&#x000b0; (SD = 7.34&#x000b0;) and maximum mean error was 16.11&#x000b0; (SD = 16.62&#x000b0;).</p><p id="P31">A histogram across all subjects, for the number of estimated accuracy error cases plotted against error range, is shown in <xref rid="F6" ref-type="fig">Fig. 6</xref>. The histogram confirmed that most of the errors were small and within the range of [&#x02212;15&#x000b0;, 15&#x000b0;] (79%), yet had a few outliers having errors as large as &#x02212;80&#x000b0;.</p><p id="P32">We summarize the percentiles of accuracy error above specific thresholds in <xref rid="T3" ref-type="table">Table III</xref> using a 15&#x000b0; interval. The percentiles for errors beyond 30&#x000b0; and 45&#x000b0; were 6.7% and 1.9% respectively. The mean absolute accuracy error and percent within 15&#x000b0; accuracy and percent within 30&#x000b0; accuracy for each type of lift are given in <xref rid="T4" ref-type="table">Table IV</xref>.</p></sec></sec><sec id="S13"><label>IV.</label><title>D<sc>iscussion</sc></title><p id="P33">The findings highlight the efficacy of the CV method in estimating A using a single camera. The mean error for each subject remained below 15&#x000b0;, with minimal outliers, indicating the algorithm&#x02019;s accuracy for the dataset.</p><sec id="S14"><label>A.</label><title>Impact of Different Estimates of Mid-Sagittal Line</title><p id="P34">The primary distinction between <italic toggle="yes">A</italic><sub>CV</sub> and <italic toggle="yes">A</italic><sub>MoCap</sub> lies in the method used to define the mid-sagittal line. In the CV method, hip orientation determines this line, while the MoCap method relies on the toes of the feet. Given that the hips initiate movement before the feet during the lifting trials&#x02019; turning phase, the difference between <italic toggle="yes">A</italic><sub>CV</sub> and <italic toggle="yes">A</italic><sub>CV</sub> would likely be smaller than between <italic toggle="yes">A</italic><sub>CV</sub> and <italic toggle="yes">A</italic><sub>MoCap</sub>. If the hips and toes rotate at the same rate, <italic toggle="yes">A</italic><sub>CV</sub> and <italic toggle="yes">A</italic><sub>MoCap</sub> angles would become the same. The vector perpendicular to the hip, which CV employs to calculate the sagittal line, closely follows the point of projection, offering a more realistic representation than the method used in <italic toggle="yes">A</italic><sub>MoCap</sub>.</p></sec><sec id="S15"><label>B.</label><title>Accuracy of Manual Measurements</title><p id="P35">In [<xref rid="R30" ref-type="bibr">30</xref>], manual measurements of the asymmetry angle showed a mean error of &#x02212;4.5&#x000b0; (SD = 4.8&#x000b0;), compared to our method&#x02019;s &#x02212;2.34&#x000b0; (SD = 10.19&#x000b0;). Despite the slightly lower SD in manual measurements, the error difference is within 15&#x000b0;, likely having minimal impact on RWL calculations. The key benefit of our approach over manual measurements is not accuracy, but its non-intrusive nature, enabling potential for fully autonomous monitoring and broadening its use beyond standard workplace tasks.</p></sec></sec><sec id="S16"><label>V.</label><title>C<sc>onclusion</sc></title><p id="P36">This article demonstrated that modern CV techniques can estimate the RNLE asymmetry angle A from monocular videos with an average error below 7&#x000b0;. By using a single camera, this approach provides a simpler and potentially more practical method for automatically determining this lifting risk factor in industrial settings, avoiding the need for multiple cameras.</p></sec></body><back><ack id="S17"><p id="P37">This work was supported in part the National Institute for Occupational Safety and Health (NIOSH/CDC), R01OH011024 (Radwin), in part by the National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention (NIOSH, CDC) R01OH011024 (Radwin), and in part by NIOSH Pilot Project Research Training Program from the University of Michigan Center for Occupational Health and Safety Engineering under Grant T42 OH008455. This article was recommended by Associate Editor D. Kaber.</p><p id="P38">This work involved human subjects or animals in its research. Approval of all ethical and experimental procedures and protocols was granted by the University of Wisconsin-Madison Institutional Review Board under Application No. 2020-0625, and performed in line with the Federal wide Assurance from the Office of Human Research Protection at the United States Department of Health and Human Services, #FWA00005399.</p></ack><fn-group><fn id="FN1"><p id="P100">Color versions of one or more figures in this article are available at <ext-link xlink:href="10.1109/THMS.2025.3539187" ext-link-type="doi">https://doi.org/10.1109/THMS.2025.3539187</ext-link>.</p></fn></fn-group><ref-list><title>R<sc>eferences</sc></title><ref id="R1"><label>[1]</label><mixed-citation publication-type="book"><name><surname>Water</surname><given-names>TR</given-names></name>, <name><surname>Putz-Anderson</surname><given-names>V</given-names></name>, and <name><surname>Garg</surname><given-names>A</given-names></name>, &#x0201c;<source>Applications manual for the revised NIOSH lifting equation</source>,&#x0201d; <publisher-name>U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health</publisher-name>. <year>1994</year>. [Online]. <comment>Available: </comment><pub-id pub-id-type="doi">10.26616/NIOSHPUB94110revised092021</pub-id></mixed-citation></ref><ref id="R2"><label>[2]</label><mixed-citation publication-type="journal"><name><surname>Lowe</surname><given-names>B</given-names></name>, <name><surname>Dempsey</surname><given-names>P</given-names></name>, and <name><surname>Jones</surname><given-names>E</given-names></name>, <collab>N. I. for Occupational Safety and H. (NIOSH)</collab>, &#x0201c;<article-title>Assessment methods used by certified ergonomics professionals</article-title>,&#x0201d; in <source>Proc. Hum. Factors Ergonom. Soc. Annu. Meeting</source>, <year>2018</year>, pp. <fpage>838</fpage>&#x02013;<lpage>842</lpage>.</mixed-citation></ref><ref id="R3"><label>[3]</label><mixed-citation publication-type="journal"><name><surname>Fox</surname><given-names>RR</given-names></name>, <name><surname>Lu</surname><given-names>M-L</given-names></name>, <name><surname>Occhipinti</surname><given-names>E</given-names></name>, and <name><surname>Jaeger</surname><given-names>M</given-names></name>, &#x0201c;<article-title>Understanding outcome metrics of the revised NIOSH lifting equation</article-title>,&#x0201d; <source>Appl. Ergonom</source>, vol. <volume>81</volume>, <year>2019</year>, <comment>Art. no. 102897</comment>.</mixed-citation></ref><ref id="R4"><label>[4]</label><mixed-citation publication-type="journal"><name><surname>Lu</surname><given-names>M-L</given-names></name>, <name><surname>Putz-Anderson</surname><given-names>V</given-names></name>, <name><surname>Garg</surname><given-names>A</given-names></name>, and <name><surname>Davis</surname><given-names>KG</given-names></name>, &#x0201c;<article-title>Evaluation of the impact of the revised national institute for occupational safety and health lifting equation</article-title>,&#x0201d; <source>Hum. Factors</source>, vol. <volume>58</volume>, pp. <fpage>667</fpage>&#x02013;<lpage>682</lpage>, <year>2016</year>.<pub-id pub-id-type="pmid">26822795</pub-id>
</mixed-citation></ref><ref id="R5"><label>[5]</label><mixed-citation publication-type="journal"><name><surname>Dempsey</surname><given-names>PG</given-names></name>, &#x0201c;<article-title>Usability of the revised NIOSH lifting equation</article-title>,&#x0201d; <source>Ergonomics</source>, vol. <volume>45</volume>, pp. <fpage>817</fpage>&#x02013;<lpage>828</lpage>, <year>2002</year>.<pub-id pub-id-type="pmid">12487684</pub-id>
</mixed-citation></ref><ref id="R6"><label>[6]</label><mixed-citation publication-type="confproc"><name><surname>Waters</surname><given-names>T</given-names></name>, <name><surname>Krieg</surname><given-names>E</given-names></name>, and <name><surname>Werren</surname><given-names>D</given-names></name>, &#x0201c;<source>Comparisons of the accuracies of two methods for assessing trunk posture associated with low back disorders</source>,&#x0201d; in <conf-name>Proc. 17th World Congr. Ergonom.</conf-name>, <year>2009</year>.</mixed-citation></ref><ref id="R7"><label>[7]</label><mixed-citation publication-type="confproc"><name><surname>Shammaa</surname><given-names>MH</given-names></name>, <name><surname>Kawachi</surname><given-names>K</given-names></name>, and <name><surname>Suzuki</surname><given-names>H</given-names></name>, &#x0201c;<source>Accurate measurements for calculating lifting index of NIOSH lifting equation using motion capture technology</source>,&#x0201d; in <conf-name>Proc. JSPE Semestrial Meeting 2007 JSPE Spring Meeting</conf-name>, <year>2007</year>.</mixed-citation></ref><ref id="R8"><label>[8]</label><mixed-citation publication-type="journal"><name><surname>Barim</surname><given-names>MS</given-names></name>, <name><surname>Lu</surname><given-names>M-L</given-names></name>, <name><surname>Feng</surname><given-names>S</given-names></name>, <name><surname>Hughes</surname><given-names>G</given-names></name>, <name><surname>Hayden</surname><given-names>M</given-names></name>, and <name><surname>Werren</surname><given-names>D</given-names></name>, &#x0201c;<article-title>Accuracy of an algorithm using motion data of five wearable IMU sensors for estimating lifting duration and lifting risk factors</article-title>,&#x0201d; in <source>Proc. Hum. Factors Ergonom. Soc. Annu. Meeting</source>, <year>2019</year>, pp. <fpage>1105</fpage>&#x02013;<lpage>1111</lpage>.</mixed-citation></ref><ref id="R9"><label>[9]</label><mixed-citation publication-type="journal"><name><surname>Lu</surname><given-names>M-L</given-names></name>, <name><surname>Feng</surname><given-names>S</given-names></name>, <name><surname>Hughes</surname><given-names>G</given-names></name>, <name><surname>Barim</surname><given-names>MS</given-names></name>, <name><surname>Hayden</surname><given-names>M</given-names></name>, and <name><surname>Werren</surname><given-names>D</given-names></name>, &#x0201c;<article-title>Development of an algorithm for automatically assessing lifting risk factors using inertial measurement units</article-title>,&#x0201d; in <source>Proc. Hum. Factors Ergonom. Soc. Annu. Meeting</source>, <year>2019</year>, pp. <fpage>1334</fpage>&#x02013;<lpage>1338</lpage>.</mixed-citation></ref><ref id="R10"><label>[10]</label><mixed-citation publication-type="journal"><name><surname>Hlucny</surname><given-names>SD</given-names></name> and <name><surname>Novak</surname><given-names>D</given-names></name>, &#x0201c;<article-title>Characterizing human box-lifting behavior using wearable inertial motion sensors</article-title>,&#x0201d; <source>Sensors</source>, vol. <volume>20</volume>, <year>2020</year>, <comment>Art. no. 2323</comment>.</mixed-citation></ref><ref id="R11"><label>[11]</label><mixed-citation publication-type="journal"><name><surname>Kok</surname><given-names>M</given-names></name>, <name><surname>Hol</surname><given-names>JD</given-names></name>, and <name><surname>Sch&#x000f6;n</surname><given-names>TB</given-names></name>, &#x0201c;<article-title>Using inertial sensors for position and orientation estimation</article-title>,&#x0201d; <year>2017</year>, <source>arXiv:1704.06053</source>.</mixed-citation></ref><ref id="R12"><label>[12]</label><mixed-citation publication-type="journal"><name><surname>Mehrizi</surname><given-names>R</given-names></name>, <name><surname>Peng</surname><given-names>X</given-names></name>, <name><surname>Xu</surname><given-names>X</given-names></name>, <name><surname>Zhang</surname><given-names>S</given-names></name>, <name><surname>Metaxas</surname><given-names>D</given-names></name>, and <name><surname>Li</surname><given-names>K</given-names></name>, &#x0201c;<article-title>A computer vision-based method for 3D posture estimation of symmetrical lifting</article-title>,&#x0201d; <source>J. Biomech</source>, vol. <volume>69</volume>, pp. <fpage>40</fpage>&#x02013;<lpage>46</lpage>, <year>2018</year>.<pub-id pub-id-type="pmid">29398001</pub-id>
</mixed-citation></ref><ref id="R13"><label>[13]</label><mixed-citation publication-type="journal"><name><surname>Bo</surname><given-names>L</given-names></name> and <name><surname>Sminchisescu</surname><given-names>C</given-names></name>, &#x0201c;<article-title>Twin Gaussian processes for structured prediction</article-title>,&#x0201d; <source>Int. J. Comput. Vis</source>, vol. <volume>87</volume>, pp. <fpage>28</fpage>&#x02013;<lpage>52</lpage>, <year>2010</year>.</mixed-citation></ref><ref id="R14"><label>[14]</label><mixed-citation publication-type="journal"><name><surname>Mehrizi</surname><given-names>R</given-names></name>, <name><surname>Peng</surname><given-names>X</given-names></name>, <name><surname>Metaxas</surname><given-names>DN</given-names></name>, <name><surname>Xu</surname><given-names>X</given-names></name>, <name><surname>Zhang</surname><given-names>S</given-names></name>, and <name><surname>Li</surname><given-names>K</given-names></name>, &#x0201c;<article-title>Predicting 3-D lower back joint load in lifting: A deep pose estimation approach</article-title>,&#x0201d; <source>IEEE Trans. Hum.-Mach. Syst</source>, vol. <volume>49</volume>, no. <issue>1</issue>, pp. <fpage>85</fpage>&#x02013;<lpage>94</lpage>, <month>Feb</month>. <year>2019</year>.</mixed-citation></ref><ref id="R15"><label>[15]</label><mixed-citation publication-type="journal"><name><surname>Mehrizi</surname><given-names>R</given-names></name>, <name><surname>Peng</surname><given-names>X</given-names></name>, <name><surname>Xu</surname><given-names>X</given-names></name>, <name><surname>Zhang</surname><given-names>S</given-names></name>, and <name><surname>Li</surname><given-names>K</given-names></name>, &#x0201c;<article-title>A deep neural network-based method for estimation of 3D lifting motions</article-title>,&#x0201d; <source>J. Biomech</source>, vol. <volume>84</volume>, pp. <fpage>87</fpage>&#x02013;<lpage>93</lpage>, <year>2019</year>.<pub-id pub-id-type="pmid">30587377</pub-id>
</mixed-citation></ref><ref id="R16"><label>[16]</label><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>X</given-names></name>, <name><surname>Hu</surname><given-names>YH</given-names></name>, <name><surname>Lu</surname><given-names>M-L</given-names></name>, and <name><surname>Radwin</surname><given-names>RG</given-names></name>, &#x0201c;<article-title>The accuracy of a 2D video-based lifting monitor</article-title>,&#x0201d; <source>Ergonomics</source>, vol. <volume>62</volume>, pp. <fpage>1043</fpage>&#x02013;<lpage>1054</lpage>, <year>2019</year>.<pub-id pub-id-type="pmid">31092146</pub-id>
</mixed-citation></ref><ref id="R17"><label>[17]</label><mixed-citation publication-type="journal"><name><surname>Chen</surname><given-names>T</given-names></name>, <name><surname>Fang</surname><given-names>C</given-names></name>, <name><surname>Shen</surname><given-names>X</given-names></name>, <name><surname>Zhu</surname><given-names>Y</given-names></name>, <name><surname>Chen</surname><given-names>Z</given-names></name>, and <name><surname>Luo</surname><given-names>J</given-names></name>, &#x0201c;<article-title>Anatomy-aware 3D human pose estimation in videos</article-title>,&#x0201d; <year>2020</year>, <source>arXiv:2002.10322</source>.</mixed-citation></ref><ref id="R18"><label>[18]</label><mixed-citation publication-type="journal"><name><surname>Lin</surname><given-names>J</given-names></name> and <name><surname>Lee</surname><given-names>GH</given-names></name>, &#x0201c;<article-title>Trajectory space factorization for deep video-based 3D human pose estimation</article-title>,&#x0201d; <year>2019</year>, <source>arXiv:1908.08289</source>.</mixed-citation></ref><ref id="R19"><label>[19]</label><mixed-citation publication-type="confproc"><name><surname>Xu</surname><given-names>J</given-names></name>, <name><surname>Yu</surname><given-names>Z</given-names></name>, <name><surname>Ni</surname><given-names>B</given-names></name>, <name><surname>Yang</surname><given-names>J</given-names></name>, <name><surname>Yang</surname><given-names>X</given-names></name>, and <name><surname>Zhang</surname><given-names>W</given-names></name>, &#x0201c;<source>Deep kinematics analysis for monocular 3D human pose estimation</source>,&#x0201d; in <conf-name>Proc. IEEE/CVF Conf. Comput. Vis. Pattern Recognit.</conf-name>, <year>2020</year>, pp. <fpage>896</fpage>&#x02013;<lpage>905</lpage>.</mixed-citation></ref><ref id="R20"><label>[20]</label><mixed-citation publication-type="confproc"><name><surname>Pavllo</surname><given-names>D</given-names></name>, <name><surname>Feichtenhofer</surname><given-names>C</given-names></name>, <name><surname>Grangier</surname><given-names>D</given-names></name>, and <name><surname>Auli</surname><given-names>M</given-names></name>, &#x0201c;<source>3D human pose estimation in video with temporal convolutions and semi-supervised training</source>,&#x0201d; in <conf-name>Proc. IEEE/CVF Conf. Comput. Vis. Pattern Recognit.</conf-name>, <year>2019</year>, pp. <fpage>7745</fpage>&#x02013;<lpage>7754</lpage>.</mixed-citation></ref><ref id="R21"><label>[21]</label><mixed-citation publication-type="journal"><name><surname>Ionescu</surname><given-names>C</given-names></name>, <name><surname>Papava</surname><given-names>D</given-names></name>, <name><surname>Olaru</surname><given-names>V</given-names></name>, and <name><surname>Sminchisescu</surname><given-names>C</given-names></name>, &#x0201c;<article-title>Human3. 6m: Large scale datasets and predictive methods for 3D human sensing in natural environments</article-title>,&#x0201d; <source>IEEE Trans. Pattern Anal. Mach. Intell</source>, vol. <volume>36</volume>, no. <issue>7</issue>, pp. <fpage>1325</fpage>&#x02013;<lpage>1339</lpage>, <month>Jul</month>. <year>2014</year>.<pub-id pub-id-type="pmid">26353306</pub-id>
</mixed-citation></ref><ref id="R22"><label>[22]</label><mixed-citation publication-type="journal"><name><surname>Waters</surname><given-names>TR</given-names></name>, <name><surname>Putz-Anderson</surname><given-names>V</given-names></name>, <name><surname>Garg</surname><given-names>A</given-names></name>, and <name><surname>Fine</surname><given-names>LJ</given-names></name>, &#x0201c;<article-title>Revised NIOSH equation for the design and evaluation of manual lifting tasks</article-title>,&#x0201d; <source>Ergonomics</source>, vol. <volume>36</volume>, pp. <fpage>749</fpage>&#x02013;<lpage>776</lpage>, <year>1993</year>.<pub-id pub-id-type="pmid">8339717</pub-id>
</mixed-citation></ref><ref id="R23"><label>[23]</label><mixed-citation publication-type="book"><name><surname>Andrew</surname><given-names>AM</given-names></name>, <source>Multiple View Geometry in Computer Vision</source>, <publisher-loc>Bingley, United Kingdom</publisher-loc>: <publisher-name>Emerald Group Publishing Limited</publisher-name>, <year>2001</year>.</mixed-citation></ref><ref id="R24"><label>[24]</label><mixed-citation publication-type="confproc"><name><surname>He</surname><given-names>K</given-names></name>, <name><surname>Gkioxari</surname><given-names>G</given-names></name>, <name><surname>Doll&#x000e1;r</surname><given-names>P</given-names></name>, and <name><surname>Girshick</surname><given-names>R</given-names></name>, &#x0201c;<source>Mask R-CNN</source>,&#x0201d; in <conf-name>Proc. IEEE Int. Conf. Comput. Vis.</conf-name>, <year>2017</year>, pp. <fpage>2980</fpage>&#x02013;<lpage>2988</lpage>.</mixed-citation></ref><ref id="R25"><label>[25]</label><mixed-citation publication-type="confproc"><name><surname>Sun</surname><given-names>K</given-names></name>, <name><surname>Xiao</surname><given-names>B</given-names></name>, <name><surname>Liu</surname><given-names>D</given-names></name>, and <name><surname>Wang</surname><given-names>J</given-names></name>, &#x0201c;<source>Deep high-resolution representation learning for human pose estimation</source>,&#x0201d; in <conf-name>Proc. IEEE/CVF Conf. Comput. Vis. Pattern Recognit.</conf-name>, <year>2019</year>, pp. <fpage>5686</fpage>&#x02013;<lpage>5696</lpage>.</mixed-citation></ref><ref id="R26"><label>[26]</label><mixed-citation publication-type="confproc"><name><surname>Xiao</surname><given-names>B</given-names></name>, <name><surname>Wu</surname><given-names>H</given-names></name>, and <name><surname>Wei</surname><given-names>Y</given-names></name>, &#x0201c;<source>Simple baselines for human pose estimation and tracking</source>,&#x0201d; in <conf-name>Proc. Eur. Conf. Comput. Vis.</conf-name>, <year>2018</year>, pp. <fpage>466</fpage>&#x02013;<lpage>481</lpage>.</mixed-citation></ref><ref id="R27"><label>[27]</label><mixed-citation publication-type="book"><name><surname>Bishop</surname><given-names>CM</given-names></name> and <name><surname>Nasrabadi</surname><given-names>NM</given-names></name>, <source>Pattern Recognition and Machine Learning</source>, vol. <volume>4</volume>. <publisher-loc>Berlin, Germany</publisher-loc>: <publisher-name>Springer</publisher-name>, <year>2006</year>.</mixed-citation></ref><ref id="R28"><label>[28]</label><mixed-citation publication-type="journal"><name><surname>Reddi</surname><given-names>SJ</given-names></name>, <name><surname>Kale</surname><given-names>S</given-names></name>, and <name><surname>Kumar</surname><given-names>S</given-names></name>, &#x0201c;<article-title>On the convergence of Adam and beyond</article-title>,&#x0201d; <year>2019</year>, <source>arXiv:1904.09237</source>.</mixed-citation></ref><ref id="R29"><label>[29]</label><mixed-citation publication-type="book"><name><surname>Armstrong</surname><given-names>TJ</given-names></name>, &#x0201c;<part-title>ACGIH TLV for hand activity level</part-title>,&#x0201d; in <source>Biomechanics in Ergonomics</source>. <publisher-loc>Boca Raton, FL, USA</publisher-loc>: <publisher-name>CRC Press</publisher-name>, <year>2007</year>, pp. <fpage>377</fpage>&#x02013;<lpage>390</lpage>.</mixed-citation></ref><ref id="R30"><label>[30]</label><mixed-citation publication-type="journal"><name><surname>Waters</surname><given-names>TR</given-names></name>, <name><surname>Baron</surname><given-names>SL</given-names></name>, and <name><surname>Kemmlert</surname><given-names>K</given-names></name>, &#x0201c;<article-title>Accuracy of measurements for the revised NIOSH lifting equation</article-title>,&#x0201d; <source>Appl. Ergonom</source>, vol. <volume>29</volume>, pp. <fpage>433</fpage>&#x02013;<lpage>438</lpage>, <year>1998</year>.</mixed-citation></ref><ref id="R31"><label>[31]</label><mixed-citation publication-type="journal"><name><surname>Dempsey</surname><given-names>PG</given-names></name> and <name><surname>Fathallah</surname><given-names>FA</given-names></name>, &#x0201c;<article-title>Application issues and theoretical concerns regarding the 1991 NIOSH equation asymmetry multiplier</article-title>,&#x0201d; <source>Int. J. Ind. Ergonom</source>, vol. <volume>23</volume>, pp. <fpage>181</fpage>&#x02013;<lpage>191</lpage>, <year>1999</year>.</mixed-citation></ref><ref id="R32"><label>[32]</label><mixed-citation publication-type="journal"><name><surname>S&#x000e1;r&#x000e1;ndi</surname><given-names>I</given-names></name>, <name><surname>Linder</surname><given-names>T</given-names></name>, <name><surname>Arras</surname><given-names>KO</given-names></name>, and <name><surname>Leibe</surname><given-names>B</given-names></name>, &#x0201c;<article-title>How robust is 3D human pose estimation to occlusion?</article-title>,&#x0201d; <year>2018</year>, <source>arXiv:1808.09316</source>.</mixed-citation></ref><ref id="R33"><label>[33]</label><mixed-citation publication-type="confproc"><name><surname>Cheng</surname><given-names>Y</given-names></name>, <name><surname>Yang</surname><given-names>B</given-names></name>, <name><surname>Wang</surname><given-names>B</given-names></name>, and <name><surname>Tan</surname><given-names>RT</given-names></name>, &#x0201c;<source>3D human pose estimation using spatio-temporal networks with explicit occlusion training</source>,&#x0201d; in <conf-name>Proc. AAAI Conf. Artif. Intell.</conf-name>, <year>2020</year>, pp. <fpage>10631</fpage>&#x02013;<lpage>10638</lpage>.</mixed-citation></ref><ref id="R34"><label>[34]</label><mixed-citation publication-type="journal"><name><surname>Zhang</surname><given-names>J</given-names></name>, <name><surname>Nie</surname><given-names>X</given-names></name>, and <name><surname>Feng</surname><given-names>J</given-names></name>, &#x0201c;<article-title>Inference stage optimization for cross-scenario 3D human pose estimation</article-title>,&#x0201d; <year>2020</year>, <source>arXiv:2007.02054</source>.</mixed-citation></ref><ref id="R35"><label>[35]</label><mixed-citation publication-type="journal"><name><surname>Ilie</surname><given-names>A</given-names></name> and <name><surname>Welch</surname><given-names>G</given-names></name>, &#x0201c;<article-title>Online control of active camera networks for computer vision tasks</article-title>,&#x0201d; <source>ACM Trans. Sensor Netw</source>, vol. <volume>10</volume>, pp. <fpage>1</fpage>&#x02013;<lpage>40</lpage>, <year>2014</year>.</mixed-citation></ref><ref id="R36"><label>[36]</label><mixed-citation publication-type="journal"><name><surname>Waters</surname><given-names>TR</given-names></name>, <name><surname>Lu</surname><given-names>M-L</given-names></name>, <name><surname>Piacitelli</surname><given-names>LA</given-names></name>, <name><surname>Werren</surname><given-names>D</given-names></name>, and <name><surname>Deddens</surname><given-names>JA</given-names></name>, &#x0201c;<article-title>Efficacy of the revised NIOSH lifting equation to predict risk of low back pain due to manual lifting: Expanded cross-sectional analysis</article-title>,&#x0201d; <source>J. Occup. Environ. Med</source>, vol. <volume>53</volume>, pp. <fpage>1061</fpage>&#x02013;<lpage>1067</lpage>, <year>2011</year>.<pub-id pub-id-type="pmid">21866048</pub-id>
</mixed-citation></ref><ref id="R37"><label>[37]</label><mixed-citation publication-type="journal"><name><surname>Bradski</surname><given-names>G</given-names></name>, &#x0201c;<article-title>The OpenCV library</article-title>,&#x0201d; <source>Dr. Dobb&#x02019;s J. Softw. Tools</source>, vol. <volume>120</volume>, pp. <fpage>122</fpage>&#x02013;<lpage>125</lpage>, <year>2000</year>.</mixed-citation></ref><ref id="R38"><label>[38]</label><mixed-citation publication-type="journal"><name><surname>S&#x000e1;r&#x000e4;ndi</surname><given-names>I</given-names></name>, <name><surname>Linder</surname><given-names>T</given-names></name>, <name><surname>Arras</surname><given-names>KO</given-names></name>, and <name><surname>Leibe</surname><given-names>B</given-names></name>, &#x0201c;<article-title>Synthetic occlusion augmentation with volumetric heatmaps for the 2018 ECCV PoseTrack challenge on 3D human pose estimation</article-title>,&#x0201d; <year>2018</year>, <source>arXiv:1809.04987</source>.</mixed-citation></ref><ref id="R39"><label>[39]</label><mixed-citation publication-type="confproc"><name><surname>Wang</surname><given-names>J</given-names></name>, <name><surname>Huang</surname><given-names>S</given-names></name>, <name><surname>Wang</surname><given-names>X</given-names></name>, and <name><surname>Tao</surname><given-names>D</given-names></name>, &#x0201c;<source>Not all parts are created equal: 3D pose estimation by modeling bi-directional dependencies of body parts</source>,&#x0201d; in <conf-name>Proc. IEEE/CVF Int. Conf. Comput. Vis.</conf-name>, <year>2019</year>, pp. <fpage>7770</fpage>&#x02013;<lpage>7779</lpage>.</mixed-citation></ref><ref id="R40"><label>[40]</label><mixed-citation publication-type="journal"><name><surname>Murugan</surname><given-names>AS</given-names></name>
<etal/>, &#x0201c;<article-title>Optimising computer vision-based ergonomic assessments: Sensitivity to camera position and monocular 3D pose model</article-title>,&#x0201d; <source>Ergonomics</source>, vol. <volume>68</volume>, pp. <fpage>120</fpage>&#x02013;<lpage>137</lpage>, <year>2025</year>.<pub-id pub-id-type="pmid">38293749</pub-id>
</mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Fig. 1.</label><caption><p id="P39">Illustration of asymmetry angle. (a) From &#x0201c;Applications Manual for the Revised NIOSH Lifting Equation&#x0201d; by Waters, T. R., Putz-Anderson, V., Garg, A., Application Manual for the Revised NIOSH Lifting Equation, DHHS (NIOSH) Publication No. 94&#x02013;110. (Revised 9/2021). In the public domain. Alt Text: Person lifting object while twisting to the right.</p></caption><graphic xlink:href="nihms-2061581-f0001" position="float"/></fig><fig position="float" id="F2"><label>Fig. 2.</label><caption><p id="P40">Left: 3-D alternative landmarks, either from computer-vision or MoCap. Right: top-down view demonstrating how body asymmetry angle is derived from the 3-D landmarks. Alt Text: Stick figure body linkages and projection of angles on the horizontal plane.</p></caption><graphic xlink:href="nihms-2061581-f0002" position="float"/></fig><fig position="float" id="F3"><label>Fig. 3.</label><caption><p id="P41">Flow chart for video-based 3-D landmark using deep learning. Left: person bounding box (green box) from the human detector [<xref rid="R24" ref-type="bibr">24</xref>]. Middle: 2-D landmarks (colored circles) detected by HR-Net [<xref rid="R25" ref-type="bibr">25</xref>] and linked over-frame by the tracking module (Xiao et al., 2018). Left and middle used slightly different frames to illustrate that successive 2-D key points are needed as inputs to VideoPose3D. Right: 3&#x02013;D landmarks estimated by VideoPose3D [<xref rid="R20" ref-type="bibr">20</xref>]. Alt Text: Left: Person lifting, Middle: Person lifting with stick figure superimposed. Right: Stick figure of person lifting.</p></caption><graphic xlink:href="nihms-2061581-f0003" position="float"/></fig><fig position="float" id="F4"><label>Fig. 4.</label><caption><p id="P42">An illustration of measuring the angle of lift asymmetry in this article (Left: an example of symmetric lift; Middle: an example of turning toward the camera; and Right: an example of turning away from the camera). Source: NIOSH. Alt Text: Left: Person lifting, Middle: Person turning left while lifting. Right: Person turning right while lifting.</p></caption><graphic xlink:href="nihms-2061581-f0004" position="float"/></fig><fig position="float" id="F5"><label>Fig. 5.</label><caption><p id="P43">Histogram plot for the hip-to-hip error. The horizontal is the error in degrees. A negative error indicates that the estimation is smaller than ground truth. Alt Text: Histogram plot of hip-to-hip error (degrees) on the <italic toggle="yes">x</italic>-axis and count on the <italic toggle="yes">y</italic>-axis. Most error occurs around zero degrees.</p></caption><graphic xlink:href="nihms-2061581-f0005" position="float"/></fig><fig position="float" id="F6"><label>Fig. 6.</label><caption><p id="P44">Histogram plot for the hip-to-ankle error. The horizontal axis is the error in degrees. A negative error indicates that the estimation is smaller than ground truth. Alt Text: Histogram plot of hip-to-ankle error (degrees) on the <italic toggle="yes">x</italic>-axis and count on the <italic toggle="yes">y</italic>-axis. Most errors occur around zero degrees.</p></caption><graphic xlink:href="nihms-2061581-f0006" position="float"/></fig><table-wrap position="float" id="T1"><label>TABLE I</label><caption><p id="P45">S<sc>ummary of</sc> A<sc>symmetry</sc> A<sc>ngle</sc> H<sc>ip-to</sc>-H<sc>ip</sc> E<sc>rror</sc> P<sc>ercentiles</sc></p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="center" valign="bottom" rowspan="1" colspan="1">Hip-to-Hip Error</th><th align="center" valign="bottom" rowspan="1" colspan="1">Error Percentiles</th></tr></thead><tbody><tr><td align="center" valign="bottom" rowspan="1" colspan="1">15&#x000b0;</td><td align="center" valign="bottom" rowspan="1" colspan="1">8.6%</td></tr><tr><td align="center" valign="bottom" rowspan="1" colspan="1">30&#x000b0;</td><td align="center" valign="bottom" rowspan="1" colspan="1">3.1%</td></tr><tr><td align="center" valign="bottom" rowspan="1" colspan="1">45&#x000b0;</td><td align="center" valign="bottom" rowspan="1" colspan="1">1.1%</td></tr><tr><td align="center" valign="top" rowspan="1" colspan="1">60&#x000b0;</td><td align="center" valign="top" rowspan="1" colspan="1">0.3%</td></tr></tbody></table></table-wrap><table-wrap position="float" id="T2"><label>TABLE II</label><caption><p id="P46">S<sc>ummary of</sc> A<sc>symmetry</sc> A<sc>ngle</sc> H<sc>ip-to</sc>-H<sc>ip</sc> E<sc>rror</sc> A<sc>cross</sc> T<sc>hree</sc> T<sc>ypes of</sc> L<sc>ifts</sc></p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="top" rowspan="1" colspan="1">Type of Lift</th><th align="left" valign="top" rowspan="1" colspan="1">Mean&#x000b1;SD (&#x000b0;)</th><th align="left" valign="top" rowspan="1" colspan="1">Percent within 15&#x000b0; Precision</th><th align="left" valign="top" rowspan="1" colspan="1">Percent within 30&#x000b0; Precision</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">SL</td><td align="left" valign="top" rowspan="1" colspan="1">4.28&#x000b1;5.61</td><td align="left" valign="top" rowspan="1" colspan="1">98%</td><td align="left" valign="top" rowspan="1" colspan="1">100%</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">TT</td><td align="left" valign="top" rowspan="1" colspan="1">7.13&#x000b1;10.25</td><td align="left" valign="top" rowspan="1" colspan="1">90%</td><td align="left" valign="top" rowspan="1" colspan="1">97%</td></tr><tr><td align="left" valign="bottom" rowspan="1" colspan="1">TA</td><td align="left" valign="bottom" rowspan="1" colspan="1">14.30&#x000b1;18.10</td><td align="left" valign="bottom" rowspan="1" colspan="1">63%</td><td align="left" valign="bottom" rowspan="1" colspan="1">80%</td></tr></tbody></table></table-wrap><table-wrap position="float" id="T3"><label>TABLE III</label><caption><p id="P47">S<sc>ummary of</sc> A<sc>symmetry</sc> A<sc>ngle</sc> H<sc>ip-to</sc>-A<sc>nkle</sc> E<sc>rror</sc> P<sc>ercentiles</sc></p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="center" valign="bottom" rowspan="1" colspan="1">Hip-to-Ankle Error</th><th align="center" valign="bottom" rowspan="1" colspan="1">Error Percentiles</th></tr></thead><tbody><tr><td align="center" valign="bottom" rowspan="1" colspan="1">15&#x000b0;</td><td align="center" valign="bottom" rowspan="1" colspan="1">21.1%</td></tr><tr><td align="center" valign="bottom" rowspan="1" colspan="1">30&#x000b0;</td><td align="center" valign="bottom" rowspan="1" colspan="1">6.7%</td></tr><tr><td align="center" valign="bottom" rowspan="1" colspan="1">45&#x000b0;</td><td align="center" valign="bottom" rowspan="1" colspan="1">1.9%</td></tr><tr><td align="center" valign="top" rowspan="1" colspan="1">60&#x000b0;</td><td align="center" valign="top" rowspan="1" colspan="1">0.8%</td></tr></tbody></table></table-wrap><table-wrap position="float" id="T4"><label>TABLE IV</label><caption><p id="P48">S<sc>ummary of</sc> A<sc>symmetry</sc> A<sc>ccuracy</sc> E<sc>rror</sc> A<sc>cross</sc> T<sc>hree</sc> T<sc>ypes of</sc> L<sc>ifts</sc></p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="center" valign="middle" span="1"/><col align="center" valign="middle" span="1"/><col align="center" valign="middle" span="1"/><col align="center" valign="middle" span="1"/></colgroup><thead><tr><th align="center" valign="top" rowspan="1" colspan="1">Type of Lift</th><th align="center" valign="top" rowspan="1" colspan="1">Mean&#x000b1;SD (&#x000b0;)</th><th align="center" valign="bottom" rowspan="1" colspan="1">Percent within 15&#x000b0; Accuracy</th><th align="center" valign="bottom" rowspan="1" colspan="1">Percent within 30&#x000b0; Accuracy</th></tr></thead><tbody><tr><td align="center" valign="bottom" rowspan="1" colspan="1">SL</td><td align="center" valign="bottom" rowspan="1" colspan="1">4.78&#x000b1;8.19</td><td align="center" valign="bottom" rowspan="1" colspan="1">96%</td><td align="center" valign="bottom" rowspan="1" colspan="1">99%</td></tr><tr><td align="center" valign="bottom" rowspan="1" colspan="1">TT</td><td align="center" valign="bottom" rowspan="1" colspan="1">15.75&#x000b1;14.84</td><td align="center" valign="bottom" rowspan="1" colspan="1">53%</td><td align="center" valign="bottom" rowspan="1" colspan="1">87%</td></tr><tr><td align="center" valign="top" rowspan="1" colspan="1">TA</td><td align="center" valign="top" rowspan="1" colspan="1">17.21&#x000b1;19.50</td><td align="center" valign="top" rowspan="1" colspan="1">58%</td><td align="center" valign="top" rowspan="1" colspan="1">83%</td></tr></tbody></table></table-wrap></floats-group></article>