<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.4" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101189458</journal-id><journal-id journal-id-type="pubmed-jr-id">31897</journal-id><journal-id journal-id-type="nlm-ta">J Occup Environ Hyg</journal-id><journal-id journal-id-type="iso-abbrev">J Occup Environ Hyg</journal-id><journal-title-group><journal-title>Journal of occupational and environmental hygiene</journal-title></journal-title-group><issn pub-type="ppub">1545-9624</issn><issn pub-type="epub">1545-9632</issn></journal-meta><article-meta><article-id pub-id-type="pmid">41592213</article-id><article-id pub-id-type="pmc">12927255</article-id><article-id pub-id-type="doi">10.1080/15459624.2025.2602758</article-id><article-id pub-id-type="manuscript">HHSPA2143323</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Enhancing and sustaining noise attenuation from hearing protection
devices: a mixed methods review of fit testing and instruction
approaches</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Gong</surname><given-names>Wei</given-names></name><xref rid="A1" ref-type="aff">1</xref><xref rid="CR1" ref-type="corresp">*</xref></contrib><contrib contrib-type="author"><name><surname>Morata</surname><given-names>Thais C</given-names></name><xref rid="A1" ref-type="aff">1</xref></contrib><contrib contrib-type="author"><name><surname>Samelli</surname><given-names>Alessandra G</given-names></name><xref rid="A2" ref-type="aff">2</xref></contrib></contrib-group><aff id="A1"><label>[1]</label>Division of Field Studies and Engineering, National
Institute for Occupational Safety and Health (NIOSH), Cincinnati, OH, USA</aff><aff id="A2"><label>[2]</label>Department of Physical Therapy, Speech-Language-Hearing
Sciences, and Occupational Therapy, Universidade de S&#x000e3;o Paulo, SP,
Brazil</aff><author-notes><corresp id="CR1"><label>*</label>Corresponding author</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>13</day><month>2</month><year>2026</year></pub-date><pub-date pub-type="ppub"><month>5</month><year>2026</year></pub-date><pub-date pub-type="epub"><day>27</day><month>1</month><year>2026</year></pub-date><pub-date pub-type="pmc-release"><day>24</day><month>2</month><year>2026</year></pub-date><volume>23</volume><issue>5</issue><fpage>319</fpage><lpage>333</lpage><abstract id="ABS1"><p id="P1">Extensive training has been shown to improve the effectiveness of hearing
protection devices (HPDs) in reducing noise exposure for workers. This study
aimed to 1) assess the evidence for short- and long-term effectiveness of HPD
fit testing paired with extensive instructions and 2) identify the type and
frequency of refresher instruction associated with maintaining its
effectiveness. A literature search was completed on February 5, 2025. The
inclusion criteria focused on uncontrolled before and after (UBA) studies that
reported personal attenuation ratings (PARs) provided by HPDs in the field. A
total of 23 UBA studies involving 5575 workers were included, meta-analyses were
performed when multiple comparable studies were located. For earplugs, retesting
immediately after extensive training increased the mean PAR by 12.88 dB (13
studies) compared with the pre-intervention PARs without instructions. The
improvement decreased to 8.84 dB (2 studies) within 6 months and further reduced
to 4.46 dB (2 studies) at 12 months. For earmuffs, only one study reported
increase in PARs of 5 dB, 2 dB, and 3 dB for immediate, short-term, and
long-term assessment, respectively. Introducing extensive refresher training
within a 6-month interval increased the mean PAR from earplugs by 1.53 dB (2
studies) compared with the post-intervention PAR retested immediately after
extensive training, with a further increase of 3.45 dB (1 study) following
annual extensive instruction. Simple refresher instructions within a 6-month
interval maintained the PAR values (1 study). However, without any refresher
training, the PAR decreased by 2.64 dB (2 studies) within 6 months and 3.09 dB
(2 studies) over 6 months or longer. Refresher training may increase the
probability that workers receive efficient protection from their HPDs. However,
more high-quality studies could help inform the optimal type and frequency of
refresher training.</p></abstract><kwd-group><kwd>Earmuff</kwd><kwd>earplug</kwd><kwd>hearing conservation program</kwd><kwd>hearing loss prevention</kwd><kwd>personal attenuation ratings (PARs)</kwd><kwd>training</kwd></kwd-group></article-meta></front><body><sec id="S1"><title>INTRODUCTION</title><p id="P2">Noise exposure has long been recognized as a common physical hazard in
various industries and workplaces (<xref rid="R42" ref-type="bibr">Themann et al.
2023</xref>). It is the primary cause of preventable hearing loss among other
health effects (<xref rid="R21" ref-type="bibr">Le et al. 2017</xref>). Worldwide,
it is estimated that occupational noise exposure contributes to 16% of the cases of
moderate or worse (&#x0003e; 40 dB HL) hearing loss in adults (Nelson and Seixas
2005) and accounts for 7 million years lived with disability (YLDs) (95% CI 4.76 to
10.1, <xref rid="R10" ref-type="bibr">GBD 2019</xref>). The National Institute for
Occupational Safety and Health (NIOSH) estimated that 22% of the United States
(U.S.) workforce has a history of occupational noise exposure (<xref rid="R17" ref-type="bibr">Kerns et al. 2018</xref>), which was responsible for 11.2% (95%
CI: 10.2 to 12.4) of YLDs due to hearing loss (<xref rid="R13" ref-type="bibr">Haile
et al. 2024</xref>). While still high, globally, the burden of occupational
noise-induced hearing loss has decreased from 1990 to 2019 by 1.72%, especially in
countries from middle and lower social demographic indices (<xref rid="R22" ref-type="bibr">C. Liu et al. 2024</xref>).</p><p id="P3">Controlling the hazard at the source is recognized as the most effective and
preferred approach to prevent occupational injury and illness (<ext-link xlink:href="https://www.cdc.gov/niosh/noise/about/noise.html" ext-link-type="uri">https://www.cdc.gov/niosh/noise/about/noise.html</ext-link>). However, a lack of
emphasis on noise control and over-reliance on hearing protection are recognized
factors that likely contribute to the continuing high burden of hearing loss among
noise-exposed workers. (<xref rid="R41" ref-type="bibr">Themann and Masterson
2019</xref>). In the U.S., hearing protection devices are labeled with a Noise
Reduction Rating (NRR) to indicate their potential for noise reduction (<xref rid="R6" ref-type="bibr">EPA 1979</xref>). The NRR is a laboratory-derived
statistical estimate that does not accurately reflect attenuation achieved by an
individual worker in the field. It has been shown repeatedly to overestimate
real-world sound reductions (<xref rid="R41" ref-type="bibr">Themann and Masterson
2019</xref>). By measuring personal attenuation ratings (PARs) on each worker
through hearing protector fit testing (HPFT) (<xref rid="R45" ref-type="bibr">Voix
et al. 2022</xref>), one can ensure that workers are receiving effective
attenuation from their HPDs.</p><p id="P4">The concept of HPFT has been around since the 1970s (<xref rid="R20" ref-type="bibr">Lempert and Edwards 1983</xref>). Advances in computer
technology have enabled the development of portable and economical fit-test systems.
Several commercial fit-test systems are available on the market, and these have seen
gradual adoption by employers and occupational hearing testing companies (<xref rid="R45" ref-type="bibr">Voix et al. 2022</xref>).</p><p id="P5">Fit-test interventions are designed to help an individual worker properly fit
their HPDs and achieve the necessary attenuation level with a particular protector.
This is accomplished in part by providing the worker with instructions on how to
choose, fit, and use HPDs. Recent studies report that HPD fit testing could help
workers wear their HPDs correctly and improve the protectors&#x02019; attenuation
(<xref rid="R12" ref-type="bibr">Gong et al. 2021</xref>, <xref rid="R29" ref-type="bibr">Murphy et al.2016</xref>). It may also help lower rates of
hearing loss. Four facilities that used fit testing in their hearing conservation
program achieved the lowest rates of hearing shift among the 14 participating sites
within the same company (<xref rid="R35" ref-type="bibr">Sayler et al. 2018</xref>).
A 2024 Cochrane systematic review reported that fit testing combined with extensive
instructions can immediately reduce noise level at workers&#x02019; ears following
the test and associated training (<xref rid="R27" ref-type="bibr">Morata et al.
2024</xref>).</p><p id="P6">A few countries have published standards recommending (Argentina, Australia,
Brazil, Italy, Russia, Uruguay, and Venezuela) or regulating (Canada, Germany,
Malaysia, US DoD) the use of fit testing as part of hearing conservation
interventions (<xref rid="R48" ref-type="bibr">Wells et al. 2023</xref>). In 2025,
the US National Institute for Occupational Safety and Health (NIOSH) published a
Science Policy Update recommending individual fit-testing for hearing protection
devices (<ext-link xlink:href="https://www.cdc.gov/niosh/docs/2025-104/pdfs/2025" ext-link-type="uri">https://www.cdc.gov/niosh/docs/2025-104/pdfs/2025</ext-link>). This Update
clarifies hearing protector recommendations in the 1998 NIOSH Criteria for a
Recommended Standard &#x02013; Occupational Noise Exposure.</p><p id="P7">There are still unanswered questions about the development and implementation
of HPD fit-testing interventions. It remains unclear how long the effectiveness of
extensive instructions can be maintained, whether instruction is necessary during
follow up fit tests, and if so, which type of instructions (extensive, simple, or
none) and how often they would need to be provided to sustain the effectiveness of
the intervention. In addition, the Cochrane review did not find any studies that
evaluated whether fit testing and training contributed to the use of HPDs (<xref rid="R27" ref-type="bibr">Morata et al., 2024</xref>). These gaps in the
evidence represent a critical barrier to implementing universal HPD fit testing in
occupational settings (<xref rid="R30" ref-type="bibr">Murphy et al.
2023</xref>).</p><p id="P8">The 2024 Cochrane review (<xref rid="R27" ref-type="bibr">Morata et al.
2024</xref>) located not only three randomized controlled trials (RCTs, with 756
participants) but also 17 uncontrolled before and after (UBA) articles with complete
datasets (<xref rid="SD1" ref-type="supplementary-material">Appendix Table
1</xref>). Among them, two articles (<xref rid="R3" ref-type="bibr">Casali and Park
1991</xref>; <xref rid="R34" ref-type="bibr">Park and Casali 1991</xref>)
reported one UBA study. In addition, one randomized controlled trial (<xref rid="R8" ref-type="bibr">Federman et al. 2021</xref>) had a UBA component. Given their
methodological design limitations, the results from the UBA studies supported the
discussion but not the conclusions. The Cochrane review authors (<xref rid="R27" ref-type="bibr">Morata et al. 2024</xref>) noted, however, that despite their
higher risk of bias (compared with RCT studies), UBA studies (given their design)
can provide additional insight in scenarios when information from RCTs is
limited.</p><p id="P9">Conducting an evidence synthesis that includes UBA studies allows one to map
the scope and depth of research on a particular topic while identifying gaps,
clarifying concepts, and informing future research directions. The primary goals of
this mixed method review were to 1) assess the evidence for effectiveness of HPD fit
testing associated with extensive instructions; specifically examining both short-
and long-term effectiveness; and 2) identify the type and frequency of refresher
instructions most strongly associated with maintaining the effectiveness of HPD fit
testing associated with extensive instructions. The secondary goal was to evaluate
the impact of fit testing effectiveness on adherence to hearing protector use.</p></sec><sec id="S2"><title>METHODS</title><p id="P10">This mixed methods review combined the framework of a scoping review with
key features of a systematic review. A scoping review delineates the coverage and
focus of a body of literature with a synthesis of evidence (<xref rid="R28" ref-type="bibr">Munn et al. 2018</xref>). It also allows the identification of
the nature of a broad field of evidence and evaluates whether a systematic review or
meta-analyses are feasible. The key features of a systematic review include framing
the question in a structured and explicit way; using a comprehensive, transparent,
and reproducible search of the literature; and conducting the quality assessment of
included studies (<xref rid="R16" ref-type="bibr">Khan et al. 2003</xref>).</p><p id="P11">The PICO (Population, Intervention, Comparison, and Outcome) model was used
to guide the formulation of the research questions, development of search
strategies, and characterization of studies or meta-analyses as in <xref rid="R27" ref-type="bibr">Morata et al. 2024</xref>. In this model, the population was
defined as workers exposed to noise who use HPDs, the intervention involved fit
testing with different formats of instructions, the comparison included various
instruction formats, and the outcome were PAR, the PAR pass rate, or the rate of HPD
use.</p><sec id="S3"><title>Systematic literature search</title><p id="P12">A systematic search was performed on Medline, Embase, PsycINFO, the
Cochrane Central Register of Controlled Trials; CINAHL) (Cumulative Index to
Nursing and Allied Health Literature), Scopus, NIOSHTIC-2 (National Institute
for Occupational Safety and Health), <ext-link xlink:href="http://ClinicalTrials.gov" ext-link-type="uri">ClinicalTrials.gov</ext-link>, and World Health Organization (WHO)
International Clinical Trials Registry Platform. The search strategy employed
was consistent with that reported in a previous Cochrane review (<xref rid="R27" ref-type="bibr">Morata et al. 2024</xref>). There were no restrictions on
language, publication year, or publication status. Citations were imported into
EndNote, where duplicates were removed. The databases were last searched on
February 5, 2025.</p></sec><sec id="S4"><title>Selection criteria</title><p id="P13">The inclusion criteria were (1) UBA studies involving fit-tested workers
who used HPDs and were exposed to noise levels of more than 80 dBA; (2) studies
that reported noise attenuation levels provided by various type of HPDs used by
workers; (3) studies involving fit testing procedures and different formats of
instructions for workers on how to properly select and fit HPDs. The primary
outcome was noise attenuation measured either as a PAR and/or PAR pass rate. PAR
pass rate is the percentage of workers who passed an established level of
sufficient attenuation from their HPDs, determined based on their individual
noise exposure levels. The secondary outcome was the HPD use rate, defined as
the percentage of workers who used HPD during their work shift.</p><p id="P14">Eligible studies were selected in two stages. First, the 17 UBA studies
identified in the previous Cochrane review (<xref rid="R27" ref-type="bibr">Morata et al. 2024</xref>) were automatically included. The last search of
the Cochrane review was February 29, 2024. Second, search results from February
29, 2024 to February 5, 2025 were imported to the web-based software Covidence.
Two review authors (WG, TM) independently screened the title and abstracts of
all studies identified from the new search. The same two authors then conducted
full-text screening. Any discrepancies between reviewers were resolved by
discussion or by consulting a third review author (AS).</p></sec><sec id="S5"><title>Data extraction and analysis</title><p id="P15">One review author extracted study characteristics using the same data
collection form from the previous Cochrane Review (<xref rid="R27" ref-type="bibr">Morata et al. 2024</xref>) and entered data in a Microsoft
Excel (Microsoft<sup>&#x000ae;</sup> Excel<sup>&#x000ae;</sup> for Microsoft 365
MSO, Version 2402) spreadsheet to perform a meta-analysis using a random-effects
model (<xref rid="R33" ref-type="bibr">Neyeloff et al. 2012</xref>). The second
review author spot-checked data entry for accuracy against the study report. For
dichotomous outcomes, risk ratios (RRs) were calculated for PAR pass rate and
the rate of HPD use. For continuous outcomes, mean differences (MDs) were used
for PAR. The sample mean and standard deviation (SD) were estimated as described
by Van et al. (2014) when studies reported only sample size, median, range
and/or interquartile range.</p><p id="P16">All training formats reported in the included studies were categorized
into two levels: extensive and simple. Extensive training was defined as any
format training that includes individualized instruction, while simple training
was defined as any training format without an individualized instruction
component. Initially, all workers underwent pre-intervention fit testing, and
the first PAR was recorded as pre-intervention PAR. Subsequently, some workers
took a post-intervention retest after receiving an extensive and/or simple
instruction either immediately (same day), in the short-term (up to 6 months),
or in the long-term (beyond 6 months). This retested PAR was recorded as the
post-intervention PAR. Later, a follow-up fit test was conducted among those who
had completed the post-intervention test to obtain follow-up PAR values; this
follow-up fit test could include or exclude refresher training. The refresher
training was also categorized as either extensive or simple instruction.</p><p id="P17">To assess the effectiveness of HPD fit testing with extensive
instruction, the post-intervention PARs were compared with the pre-intervention
PARs. This comparison allows for an evaluation of how long the effectiveness of
extensive instructions is maintained.</p><p id="P18">To determine whether refresher instruction was necessary to maintain the
effectiveness of extensive instruction, the follow-up PARs were compared with
the post-intervention PAR values obtained immediately after extensive
instruction. This comparison also allows evaluation of which type of refresher
instruction (extensive, simple, or none) would be most effective and how often
it would need to be provided to maintain the effectiveness of extensive
instruction.</p><p id="P19">In addition, the rate of HPD use among workers was compared between the
pre-and post-intervention fit testing, as well as between follow-up and the
post-intervention fit testing. This comparison aims to examine whether HPD fit
testing accompanied by instruction enhances adherence to HPD use.</p><p id="P20">The data were pooled from studies deemed sufficiently homogenous in
terms of intervention, participants, and settings. A meta-analysis was performed
with random-effects model, if more than one study provided useable data in any
single comparison. Statistical significance alpha levels were set at 0.05.</p></sec><sec id="S6"><title>Assessment of risk of bias and quality of evidence</title><p id="P21">The authors aimed to use the Risk of Bias in Non-randomized Studies of
Interventions (ROBINS-I) tool to assess the risk of bias in the eligible UBA
studies (<xref rid="R39" ref-type="bibr">Sterne et al. 2024</xref>). If the
evidence allowed, the five considerations (risk of bias, inconsistency,
imprecision, indirectness, and publication bias) of the Grading of
Recommendations, Assessment, Development and Evaluation (GRADE) method was
employed to assess the certainty of a body of evidence as it related to the
studies that contributed data for the pre-specified outcomes.</p></sec></sec><sec id="S7"><title>RESULTS</title><sec id="S8"><title>Characteristics of Included studies</title><p id="P22">The latest search yielded 284 references in total. During the title and
abstract screening, 277 were not eligible for inclusion. The remaining seven
articles underwent full-text review, and one was excluded because of incomplete
data. This process resulted in 6 recent UBA studies being added to 17 UBA
studies (reported in 18 articles) identified in the 2024 Cochrane review (<xref rid="R27" ref-type="bibr">Morata et al. 2024</xref>). A total of 23 UBA
studies with completed datasets were included in this review (<xref rid="F1" ref-type="fig">Figure 1</xref>, <xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>). No RCT studies
were found. Workers from 14 studies (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>) who did not
achieve the desired PAR during the initial fit tests and/or with incorrect fit
skill received an intervention followed by follow-up fit tests. In contrast,
workers from nine studies (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>) underwent initial and follow-up fit tests
regardless of the PAR levels they achieved at their initial tests.</p><p id="P23">Of 5575 workers who were recruited in the 23 UBAs, a total of 4629
workers were eligible and participated in the initial fit test to obtain their
pre-intervention PARs. Of these, 4184 received extensive instructions and were
fit tested to estimate their post-intervention PARs. Among them, 3374 were
retested on the same day when they received extensive instructions, 456 were
tested within 6 months after receiving extensive instructions, and 351 were
tested more than 6 months later. In addition, 1275 took a third test to estimate
their follow-up PARs, either within 6 months or beyond six months after their
second test.</p><p id="P24">Seventeen studies were conducted in manufacturing facilities with 11
located in China, two in the United States, with one each from Canada, Taiwan,
Korea, and Japan. In addition, one study took place at the U.S. Department of
Defense, two were in the U.S. Marine Corps, and one was at an energy
distribution company in Canada. Furthermore, two studies were performed at a
public university in Brazil (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>). All workers reported being exposed to noise at
work. Fourteen studies documented noise exposure levels ranging from 80 to 107
dBA, while some peak levels from rifles reached up to 160 dB SPL. Only five
studies provided detailed descriptions of noise measurement methods and results
(<xref rid="R12" ref-type="bibr">Gong et al. 2021</xref>; <xref rid="R23" ref-type="bibr">J. Liu et al. 2024</xref>; <xref rid="R29" ref-type="bibr">Murphy et al. 2016</xref>; <xref rid="R38" ref-type="bibr">Shu et al.
2025</xref>; <xref rid="R49" ref-type="bibr">Zhong et al. 2023</xref>). The
ages of participants, reported by 16 studies, ranged from 18 to 69 years old
(<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>).
Three studies included only male participants, one study primarily included
female workers, and 17 studies reported a predominance of male participants
(<xref rid="SD1" ref-type="supplementary-material">Appendix Table
1</xref>).</p><p id="P25">Eight studies used the real-ear attenuation at threshold (REAT, <xref rid="R15" ref-type="bibr">ISO 2018</xref>) method to estimate PAR values,
while the remaining 15 studies used the microphone in the real-ear (MIRE, <xref rid="R1" ref-type="bibr">ANSI 2018</xref>) method (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>). Only one study
measured PAR levels for canal caps, two studies tested earmuffs, and the
remaining studies tested different types of earplugs including foam, pre-molded,
and push-to-fit earplugs (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>).</p><p id="P26">Three types of training format were defined: extensive, simple, and no
instruction. To evaluate the effectiveness of intervention, 14 studies compared
no instruction with extensive instruction (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>); three studies
compared extensive instruction with simple instruction &#x02014; specifically,
HPD manufacturers&#x02019; package instruction in two studies (<xref rid="R2" ref-type="bibr">Assun&#x000e7;&#x000e3;o et al. 2019</xref>; <xref rid="R43" ref-type="bibr">Takada et al. 2020</xref>) and group instruction in one
study (<xref rid="R44" ref-type="bibr">Tsukada and Sakakibara 2008</xref>). In
addition, one study reported the intervention effect of a short video
instruction (simple), expert-fit instruction (extensive), or integrated video
training and expert-fit instruction (extensive), compared with no instruction
(<xref rid="R8" ref-type="bibr">Federman et al. 2021</xref>).</p><p id="P27">Twenty-one studies (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>) measured the immediate effects of fit testing
combined with instruction. Eight studies assessed short-term effects, while four
studies measured long-term effects (<xref rid="SD1" ref-type="supplementary-material">Appendix Table 1</xref>). Eight studies
evaluated the effect of follow up fit testing with refresher training weekly
(<xref rid="R26" ref-type="bibr">Martin et al. 2019</xref>), biannually
(<xref rid="R2" ref-type="bibr">Assun&#x000e7;&#x000e3;o et al. 2019</xref>),
or over a period within 6 months (<xref rid="R11" ref-type="bibr">Gong et al.
2019</xref>; Liu et al. 2020; <xref rid="R44" ref-type="bibr">Tsuakda and
Sakakibara 2008</xref>; <xref rid="R25" ref-type="bibr">L&#x000fc; et al.
2022</xref>) or in 12 months or more (<xref rid="R9" ref-type="bibr">Fu et
al. 2024</xref>; Liu et al. 2020; <xref rid="R29" ref-type="bibr">Murphy et
al. 2016</xref>). In addition, Kim et al. provided annual individualized
instruction to earplug users for four consecutive years to evaluate the effect
of annual training (<xref rid="R18" ref-type="bibr">Kim et al. 2019</xref>).
Only one study examined whether fit testing with instructions contributed to the
use of hearing protection (<xref rid="R44" ref-type="bibr">Tsukada and
Sakakibara 2008</xref>).</p><p id="P28">Regarding the assessment of risk of bias and quality of evidence, it is
important to note that all the UBA studies identified in this review reported
only one pre-intervention outcome measurement and one post-intervention outcome
measurement for each participant. While the ROBINS-I tool is particularly
relevant for UBA studies, it is not appropriate to those that rely on single
pre- and/or post-intervention outcome measurements for each participant. Such
studies are typically judged to be at serious or critical risk of bias because
it is impossible to determine whether pre-post changes are due to the
intervention rather than other factors (<xref rid="R39" ref-type="bibr">Sterne
et al. 2024</xref>). Furthermore, UBA studies are observational in nature
and focus solely on subjects who underwent the intervention. As a result, they
usually warrant downgrading from low to very low quality according to the GRADE
handbook (<xref rid="R36" ref-type="bibr">Sch&#x000fc;nemann et al. 2013</xref>).
Therefore, all included studies were judged to be at serious risk of bias, which
resulted in very low quality of evidence and should be considered with
caution.</p></sec><sec id="S9"><title>Effects of fit testing of HPD with extensive instructions</title><sec id="S10"><title>Immediate effects</title><p id="P29">Compared with the pre-intervention PARs without instructions,
earplug users experienced an immediate post-intervention PAR increase of
12.88 dB (95% CI: 10.09 to 15.66; 12 studies, Z = 9.87, P &#x0003c; 0.00001),
and the PAR pass rates improved with a risk ratio (RR) of 1.60 (95% CI: 1.13
to 2.27; 7 studies, Z = 3.69, P = 0.0002). For earmuff users, the
post-intervention PAR increased by 5.00 dB (95% CI: 3.99 to 6.01; 1 study, Z
= 15.48, P &#x0003c; 0.00001), and the PAR pass rate improved with an RR of
1.14 (95% CI: 1.07 to 1.21; 1 study, Z = 9.72, P &#x0003c; 0.00001).</p><p id="P30">When compared with the pre-intervention PARs with simple
instructions, the post-intervention mean PARs for earplugs increased by 5.06
dB (95% CI: 3.99 to 6.01; 3 studies, Z = 9.72, P &#x0003c; 0.00001), and the
PAR pass rate rose with an RR of 1.13 (95% CI: 1.06 to 1.19; 3 studies, Z =
4.01, P &#x0003c; 0.0001).</p><p id="P31">No study examined whether fit testing with extensive training could
immediately affect the rate of HPD use.</p></sec><sec id="S11"><title>Short-term effects</title><p id="P32">Compared with the pre-intervention PARs without instructions, the
6-month post-intervention visits (<xref rid="R11" ref-type="bibr">Gong et
al. 2019</xref>, Liu et al. 2020) showed an increase in the mean PAR
from earplugs of 8.84 dB (95% CI &#x02212;3.70 to 21.38; 2 studies, Z = 8.96,
P &#x0003c; 0.00001), while the PAR from earmuffs increased by 2 dB (95% CI
0.53 to 3.47; Z = 2.67, P = 0.008). PAR pass rates for earplugs also
increased (<xref rid="R11" ref-type="bibr">Gong et al. 2019</xref>), with an
RR of 2.08 (95% CI 1.74 to 2.50; 1 study, Z = 7.88, P &#x0003c; 0.00001).
Overall, the short-term improvements in mean PAR were observed to be lower
than the immediate effects.</p><p id="P33">Compared with the pre-intervention PARs with simple instruction,
retests at 3-week (<xref rid="R34" ref-type="bibr">Park and Casali
1991</xref>) and two-month intervals (<xref rid="R44" ref-type="bibr">Tsukada and Sakakibara 2008</xref>) showed increases in the mean PAR
for earplugs, earmuff, and canal cap of 6.22 dB (95% CI 1.19 to 11.26; 2
studies, Z = 2.42, P = 0.02), 1.60 dB (95% CI &#x02212;2.7 to 9.97; 1 study,
Z = 9.21, P &#x0003c; 0.00001), and 3.50 dB (95% CI &#x02212;2.7 to 9.97; 1
study, Z = 1.06, P = 0.29), respectively. In addition, the rate of earplug
use increased from 46% to 66% over the two-month period following the
training (<xref rid="R44" ref-type="bibr">Tsukada and Sakakibara
2008</xref>). At a one-month follow-up visit, 26 of 37 workers from a
printing enterprise self-reported that they increased the use of HPD use
when exposed to noise in their work shift (<xref rid="R25" ref-type="bibr">L&#x000fc; et al. 2022</xref>).</p></sec><sec id="S12"><title>Long-term effects</title><p id="P34">In the 12-month retest (<xref rid="R18" ref-type="bibr">Kim et al.
2019</xref>; Liu et al. 2020), an increase in the mean PAR of 4.46 dB
(95% CI &#x02212;15.86 to 7.32; 2 studies, Z = 2.79, P = 0.005) for earplugs
was observed when comparing post-intervention PAR with pre-intervention PAR.
However, this increase was smaller than the retest conducted within 6 month
(8.84 dB) and significantly less than the immediate retest following
extensive instructions (12.88 dB) (<xref rid="F2" ref-type="fig">Figure
2</xref>). No study examined whether fit testing combined with extensive
training could affect the long-term rate of HPD use, nor did any study
compare the post-intervention PARs from simple instruction with the
pre-intervention PARs.</p><p id="P35"><xref rid="F2" ref-type="fig">Figure 2</xref> shows the immediate,
short-term, and long-term effectiveness of fit testing of earplugs with
extensive instruction when compared with pre-intervention fit testing
without instruction.</p></sec></sec><sec id="S13"><title>Effects of fit testing of HPD with refresher instruction</title><sec id="S14"><title>Short-term effects</title><p id="P36">The follow-up fit test, along with extensive refresher instruction
within 6 months (<xref rid="R2" ref-type="bibr">Assun&#x000e7;&#x000e3;o et
al. 2019</xref>; <xref rid="R26" ref-type="bibr">Martin et al.
2019</xref>), increased the mean PAR values of earplugs by 1.53 dB (95%
CI 0.99 to 2.06; 2 studies, Z = 5.25, P &#x0003c; 0.00001), when compared
with the post-PAR immediate retest following extensive instructions. The PAR
pass rates for earplugs remained stable (<xref rid="R2" ref-type="bibr">Assun&#x000e7;&#x000e3;o et al, 2019</xref>), with an RR of 0.97 (95% CI
0.43 to 2.71; 1 study, Z = 0.29, P = 0.77).</p><p id="P37">Interestingly, simple refresher instruction at the follow-up fit
test did not show changes either in PAR values (mean difference 0.65 dB, 95%
CI &#x02212;3.75 to 5.10; 1 study, Z = 0.55, P = 0.58) or the PAR pass rate
(RR 0.86, 95% CI 0.32 to 2.32; 1 study, Z = 0.96, P = 0.34).</p><p id="P38">However, a follow-up fit test conducted alone without refresher
instruction within 6 months (<xref rid="R11" ref-type="bibr">Gong et al.
2019</xref>; Liu et al. 2020; <xref rid="R25" ref-type="bibr">L&#x000fc;
et al. 2022</xref>; <xref rid="R44" ref-type="bibr">Tsukada and
Sakakibara 2008</xref>) indicated that the mean PAR values for earplugs
decreased by 2.64 dB (95% CI &#x02212;0.44 to 5.71; 4 studies, Z = 2.51, P =
0.005), while the mean PAR values for earmuff decreased by 2 dB (95% CI 0.81
to 3.19; 1 study, Z = 3.29, P = 0.001; <xref rid="R24" ref-type="bibr">Liu
and Yang 2018</xref>).</p></sec><sec id="S15"><title>Long-term effects</title><p id="P39">The follow-up fit test conducted with extensive refresher
instruction after 12 months (<xref rid="R18" ref-type="bibr">Kim et al.
2019</xref>) revealed an increase in the mean PAR values of earplugs of
3.45 dB (95% CI 2.01 to 4.88; Z = 5.16, P &#x0003c; 0.0001) when compared
with the immediate retest following extensive instructions. No study
examined the long-term effects of a follow-up fit test with simple refresher
instruction.</p><p id="P40">In contrast, the follow-up fit test conducted without refresher
instruction after 1 year led to a decrease in the mean PAR for earplugs by
3.09 dB (95% CI &#x02212;2.19 to 8.37; 2 studies, Z = 1.82, P = 0.07, <xref rid="R18" ref-type="bibr">Kim et al.,2019</xref>, Liu et al. 2020) when
compared with the post-intervention PAR with extensive instruction. PAR pass
rates for earplugs also decreased (<xref rid="R24" ref-type="bibr">Liu and
Yang 2018</xref>), with a RR of 0.64 (95% CI 0.16 to 2.59; Z = 1.82, P =
0.07). For earmuffs, the mean PAR decreased by 1 dB (95% CI &#x02212;0.78 to
2.78; 1 study, Z = 1.10, P = 0.27; <xref rid="R24" ref-type="bibr">Liu and
Yang 2018</xref>). However, none of these decreases were statistically
significant.</p><p id="P41"><xref rid="F3" ref-type="fig">Figure 3</xref> illustrates the
short-term and long-term effectiveness of fit test for earplugs with or
without refresher instruction, in comparison with the retest immediately
after extensive instruction.</p></sec></sec></sec><sec id="S16"><title>DISCUSSION</title><sec id="S17"><title>Effects of fit testing of HPD with extensive instructions</title><p id="P42">This mixed method review of 23 UBA studies revealed that providing
extensive instructions immediately followed by fit testing achieved the greatest
increase in PAR values and PAR pass rates for earplugs, compared with the
pre-intervention PARs from fit testing without instruction. The increase in mean
PAR (MD 12.88 dB; 95% CI: 10.03 to 15.66) is greater than that reported in the
Cochrane review (MD 8.34 dB; 95% CI: 7.32 to 9.36). One possible explanation for
this difference is that 14 UBA studies only provided intervention for workers
who failed to achieve the desired PAR and/or with inappropriate use of HPDs,
indicating that the pre-intervention PAR values for these workers were
relatively lower than those in the randomized controlled trials (RCTs) analyzed
in the Cochrane review (<xref rid="R27" ref-type="bibr">Morata et al.
2024</xref>). However, the increase in PAR levels is consistent regardless
of the difference in the study design and rigor.</p><p id="P43">When there was a time interval of one week to 17 months between the
extensive training and the post-intervention fit tests, a longer time interval
between the instructions and the fit test was associated with lower attenuation.
An exception was noted in the <xref rid="R34" ref-type="bibr">Park and Casali
(1991)</xref> study, where workers received extensive instructions before a
3-week experimental period and were fit tested once a week. Their 3-week
post-intervention mean PARs for earplugs improved by 12 dB compared with their
pre-intervention PARs (<xref rid="R34" ref-type="bibr">Park and Casali
1991</xref>). This increase was even greater than the immediate effects
observed in the randomized controlled trial (RCT) study (<xref rid="R8" ref-type="bibr">Federman et al. 2021</xref>). Beyond the different study
designs, a possible explanation is that frequent fit testing (once a week) may
enhance the effectiveness of extensive instruction.</p><p id="P44">For earmuff, one study (<xref rid="R24" ref-type="bibr">Liu and Yang
2018</xref>) observed improvements in mean post-intervention PAR values at
immediate, 6-month, and 12-month test after participants received extensive
instruction. The results, along with those from earplugs, consistently show that
an interval of 6 months or more between instructions and fit testing
significantly reduces the increase in PAR values from baseline. This finding
indicates that providing extensive instruction immediately followed by a fit
test leads to the greatest improvement in PAR values or pass rates. Conversely,
longer intervals between instructions and fit testing (whether 6 or 12 months)
are associated with lower increase in attenuation. This suggests that a
follow-up fit test is necessary after workers have demonstrated their ability to
receive effective protection following extensive training.</p><p id="P45">One study reported a change in the rate of earplug use, showing an
increase from 4% to 66% over two months following extensive training (<xref rid="R44" ref-type="bibr">Tsukada and Sakakibara 2008</xref>). In another
study, workers indicated that they increased their earplug usage after initial
fit tests, however, the rate of HPD use was not reported (<xref rid="R25" ref-type="bibr">L&#x000fc; et al. 2022</xref>). A 2024 study found that 138
out of 192 workers removed their earplugs during their initial visit for
conversations or equipment checks; however, this number decreased to only 94
workers citing the same reasons after 17 months of their fit testing and
instructions (<xref rid="R9" ref-type="bibr">Fu et al. 2024</xref>). These
findings suggest that measuring the rate of HPD use may not comprehensively
assess the impact of HPD fit testing since workers are generally required to
wear HPDs when exposed to hazardous noise. <xref rid="R31" ref-type="bibr">Neitzel and Seixas (2005)</xref> noted that construction workers who
reported &#x0201c;always&#x0201d; using HPDs in high noise environments actually
wore them only one-third of the time when their noise exposure exceeded 85 dBA.
Addressing factors contributing to non-use&#x02014;such as communication,
comfort, and convenience&#x02014;could enhance the consistency of HPD usage.
Alternative metrics like HPD wearing duration, frequency of removal, or comfort
levels may serve as better indicators for assessing consistent HPD use.</p></sec><sec id="S18"><title>Effects of fit testing of HPD with refresher instruction</title><p id="P46">Evidence from two uncontrolled studies (<xref rid="R26" ref-type="bibr">Martin et al. 2019</xref>; <xref rid="R2" ref-type="bibr">Assun&#x000e7;&#x000e3;o et al. 2019</xref>) indicated that when the same
subjects received extensive refresher instructions (either weekly or
biannually), the mean post-training PAR improved by an average of 1.53 dB
compared with the previous post-intervention PAR (95% CI: 0.99 to 2.06). In
another study, annual fit testing combined with extensive instructions for 172
workers over 2 years and 30 workers over 4 years resulted in a mean PAR increase
of 3.45 dB (95% CI: 2.01 to 4.88) at the 4th year test, compared with the
post-intervention PAR values measured immediately after extensive training at
the first year (<xref rid="R18" ref-type="bibr">Kim et al. 2019</xref>).</p><p id="P47">Extensive instructions can be time-consuming. <xref rid="R29" ref-type="bibr">Murphy et al. (2016)</xref> reported that training sessions
lasted between 3 to 7 minutes, while <xref rid="R12" ref-type="bibr">Gong et al.
(2021)</xref> noted that the duration of fit testing combined with extensive
training varied from 5 to 30 minutes, depending on the number of times workers
needed to be trained, refitted, and retested. In contrast, group training, video
presentations, or written instructions typically require less time and fewer
resources than individualized extensive instruction. One study provided a
10-minute hearing health education and HPD training for groups of 8 to 16 U.S.
Marine Corps recruits (<xref rid="R19" ref-type="bibr">Kulinski et al.
2024</xref>). This group training combined a standardized script, visual
inspection, and immediate feedback from an occupational audiology staff member
who provided recruits with the necessary skill to properly insert their HPDs.
The study authors found a significant immediate increase of 14.6 dB in
post-intervention PAR, with a slight decrease at one-month follow-up, yet still
above pre-intervention levels. The study indicates that implementing small-group
training at large-scale in-processing events, where resource constraints may
limit one-on-one intervention, could be considered a viable option for refresher
instruction (<xref rid="R19" ref-type="bibr">Kulinski et al. 2024</xref>).</p><p id="P48">This mixed method review found that providing follow-up fit testing with
simple refresher instruction at 6-month intervals allows workers to achieve the
same level of protection as they did with initial extensive training. Therefore,
this review suggests that simple instruction could serve as an alternative
intervention to maintain the effectiveness of extensive instruction once workers
are proficient in selecting and wearing hearing protection devices correctly.
However, no studies have examined the long-term effects (beyond 6 months) of
follow-up using refresher simple instruction.</p><p id="P49">In contrast, the follow-up fit test without refresher instruction
resulted in a decrease in the mean PAR for both earplugs (<xref rid="R18" ref-type="bibr">Kim et al. 2019</xref>; Liu et al. 2020) and earmuffs (<xref rid="R24" ref-type="bibr">Liu and Yang 2018</xref>) over 6 months to 1 year.
This finding confirms that periodic follow-up fit testing with some forms of
refresher instruction is necessary after workers have demonstrated their ability
to achieve effective protection following extensive training.</p></sec></sec><sec id="S19"><title>LIMITATIONS</title><p id="P50">Because of the high bias present in the UBA studies included in this review,
no definitive conclusions can be drawn regarding the type and frequency of refresher
instruction needed. In addition, the effectiveness of training &#x02013; both
short-term and long-term &#x02013; is likely influenced by noise exposure levels.
This is especially relevant for workers exposed to noise level of 85 dBA or lower,
as they may not need as much attenuation from their HPDs during daily work as they
did after extensive training.</p><p id="P51">Furthermore, publication bias may have influenced our evaluation of the
effects of extensive instruction from four UBA studies that were partially funded by
the manufacturer of one of the systems used as an intervention. This funding source
may have had an interest in publishing studies that demonstrate a preventive effect
of fit testing for HPDs (<xref rid="R11" ref-type="bibr">Gong et al. 2019</xref>;
<xref rid="R12" ref-type="bibr">Gong et al. 2021</xref>; <xref rid="R24" ref-type="bibr">Liu and Yang 2018</xref>; Liu et al. 2020).</p></sec><sec id="S20"><title>CONCLUSIONS</title><sec id="S21"><title>Implications for practice</title><p id="P52">The findings from this mixed method review indicate that providing
extensive training can immediately enhance the noise attenuation offered by
HPDs, aligning with the results reported in the Cochrane review published in
early 2024. However, this initial increase in effectiveness tends to diminish
over time. Fortunately, implementing periodic follow-up fit testing, along with
either extensive or simple refresher instruction, can help maintain&#x02014;and
in some cases even improve&#x02014;the effectiveness of the initial training. In
other words, periodic follow-up fit testing with refresher training is
beneficial for workers who demonstrate their ability to achieve effective
protection.</p><p id="P53">From a practical perspective, biannual, annual, or biennial training
would be more feasible than weekly sessions. However, few high-quality studies
have evaluated the effects of periodic refresher instruction or the maintained
effects of such instructions. These findings align with a previous Cochrane
review (<xref rid="R40" ref-type="bibr">Tikka et al. 2017</xref>), which noted a
limited number of studies examining the effectiveness of refresher training.
Further research is likely to have an important impact and could modify the
conclusions reached in this review.</p></sec><sec id="S22"><title>Implications for research</title><p id="P54">Future randomized controlled trials (RCTs) could examine the need for
optimal time intervals between tests with extensive instruction and periodic
testing combined with refresher instructions. This mixed methods review
indicates that periodic fit testing of HPDs with extensive or simple refresher
instruction could help maintain the achieved attenuation from HPDs. To support
this finding, RCTs of high or moderate quality could offer greater certainty to
enhance the implementation of the intervention in workplace settings. Future
studies also could use hierarchical clusters of noise exposure levels in the
data analysis to better evaluate the training effects across different time
frame.</p><p id="P55">For an HPD fit-testing strategy to be widely accepted in industry, it is
important to identify its key elements and develop an efficient implementation
model. In addition, addressing factors that contribute to non-use of
HPDs&#x02014;such as communication, comfort, and convenience&#x02014;could improve
the consistency of hearing protector use. Other outcomes, such as HPD wearing
time, frequency of removal, and comfort levels, may also serve as valuable
indicators for assessing consistency in HPD use.</p><p id="P56">As noted in the Cochrane review (<xref rid="R27" ref-type="bibr">Morata
et al. 2024</xref>), two variables have not yet been explicitly
investigated: the effect of experience with HPD use and past training history.
Therefore, controlling for these variables in future studies appears
warranted.</p></sec></sec><sec sec-type="supplementary-material" id="SM1"><title>Supplementary Material</title><supplementary-material id="SD1" position="float" content-type="local-data"><label>Appendix Table 1 Characteristics of included studies [Ordered Alphabetically
by First Author's Last Name and Publication Year]</label><media xlink:href="NIHMS2143323-supplement-Appendix_Table_1.docx" id="d67e614" position="anchor"/></supplementary-material></sec></body><back><ack id="S24"><title>FUNDING</title><p id="P58">This work was sponsored by intramural research funds from the National
Institute for Occupational Safety and Health, USA.</p></ack><fn-group><fn id="FN1"><p id="P59">DISCLAIMER</p><p id="P60">The findings and conclusions in this report are those of the authors and
do not necessarily represent the official position of the National Institute for
Occupational Safety and Health, Centers for Disease Control and Prevention.</p></fn><fn id="FN2"><p id="P61">GENERATIVE ARTIFICIAL INTELLIGENCE (AI) STATEMENT</p><p id="P62">Authors used the CDC Chatbot (large language model GPT-4o mini) to
review this submission for grammar, clarity, conciseness, and consistency to
enhance its readability and academic tone.</p></fn></fn-group><sec sec-type="data-availability" id="S23"><title>DATA AVAILABILITY STATEMENT</title><p id="P57">The authors confirm that the data supporting the findings of this study are
available within the article.</p></sec><ref-list><title>REFERENCES</title><ref id="R1"><mixed-citation publication-type="book"><collab>American National Standard Institute
(ANSI)</collab>. <source>Performance criteria for systems that estimate the attenuation of passive hearing protectors for individual users</source>.
<publisher-loc>Washington, DC</publisher-loc>:
<publisher-name>ANSI</publisher-name>, <year>2018</year>. (ANSI
S12.71).</mixed-citation></ref><ref id="R2"><mixed-citation publication-type="journal"><name><surname>Assun&#x000e7;&#x000e3;o</surname><given-names>CH</given-names></name>, <name><surname>Trabanco</surname><given-names>JC</given-names></name>, <name><surname>Gomes</surname><given-names>RF</given-names></name>, <etal/>
<year>2019</year>. <article-title>Longitudinal evaluation of a hearing protector
fit training program</article-title>. <source>La Medicina del Lavoro</source>. <volume>110</volume>(<issue>4</issue>):<fpage>304</fpage>.
DOI: <pub-id pub-id-type="doi">10.23749/mdl.v110i4.8214</pub-id>.<pub-id pub-id-type="pmid">31475692</pub-id>
</mixed-citation></ref><ref id="R3"><mixed-citation publication-type="journal"><name><surname>Casall</surname><given-names>JG</given-names></name>, <name><surname>Park</surname><given-names>MY</given-names></name>.<year>1991</year>. <article-title>Real-ear attenuation under laboratory
and industrial test conditions as provided by selected hearing
protectors</article-title>. <source>Proceedings of the Human Factors Society</source>
<volume>2</volume>:<fpage>1110</fpage>&#x02013;<lpage>1114</lpage>. DOI: <pub-id pub-id-type="doi">10.1177/154193129103501519</pub-id>.</mixed-citation></ref><ref id="R4"><mixed-citation publication-type="journal"><name><surname>Chiu</surname><given-names>CC</given-names></name>, <name><surname>Wan</surname><given-names>TJ</given-names></name>
<year>2020</year>. <article-title>Individual fit testing of hearing-protection
devices based on microphones in real ears among workers in industries with
high-noise-level manufacturing</article-title>. <source>Int J Environ Res Public Health</source>.
<volume>17</volume>(<issue>9</issue>):<fpage>3242</fpage>. DOI: <pub-id pub-id-type="doi">10.3390/ijerph17093242</pub-id>.<pub-id pub-id-type="pmid">32384734</pub-id>
</mixed-citation></ref><ref id="R5"><mixed-citation publication-type="journal"><name><surname>Copelli</surname><given-names>F</given-names></name>, <name><surname>Behar</surname><given-names>A</given-names></name>, <name><surname>Le</surname><given-names>TN</given-names></name>, <etal/>
<year>2021</year>. <article-title>Field attenuation of foam
earplugs</article-title>. <source>Safe and health Work</source>.
<volume>12</volume>(<issue>2</issue>):<fpage>184</fpage>&#x02013;<lpage>191</lpage>.
DOI: <pub-id pub-id-type="doi">10.1016/j.shaw.2020.09.006</pub-id>.</mixed-citation></ref><ref id="R6"><mixed-citation publication-type="book"><collab>EPA</collab>
<year>1979</year>. <source>Federal Regulation 44 (190), 40CFR 211 Part 211, Noise Labeling Requirements for Hearing Protectors</source>
(<publisher-name>Environmental Protection Agency, Government Publication
Office</publisher-name>, <publisher-loc>Washington, DC</publisher-loc>), pp
<fpage>130</fpage>&#x02013;<lpage>156</lpage>. <ext-link xlink:href="https://www.ecfr.gov/current/title-40/chapter-I/subchapter-G/part-211" ext-link-type="uri">https://www.ecfr.gov/current/title-40/chapter-I/subchapter-G/part-211</ext-link>.</mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>Federman</surname><given-names>J</given-names></name>, <name><surname>Duhon</surname><given-names>C</given-names></name>. <year>2016</year>.<article-title>The viability of hearing protection
device fit-testing at navy and marine corps accession
points</article-title>. <source>Noise Health</source>.
<volume>18</volume>(<issue>85</issue>):<fpage>303</fpage>&#x02013;<lpage>311</lpage>.
DOI: <pub-id pub-id-type="doi">10.4103/1463-1741.195806</pub-id>.<pub-id pub-id-type="pmid">27991461</pub-id>
</mixed-citation></ref><ref id="R8"><mixed-citation publication-type="journal"><name><surname>Federman</surname><given-names>J</given-names></name>, <name><surname>Karch</surname><given-names>SJ</given-names></name>, <name><surname>Duhon</surname><given-names>C</given-names></name>. <year>2021</year>. <article-title>How hearing conservation training
format impacts personal attenuation ratings in US Marine Corps Training
Recruits</article-title>. <source>Int J Audiol</source>.
<volume>60</volume>(<issue>2</issue>):<fpage>151</fpage>&#x02013;<lpage>159</lpage>.
DOI: <pub-id pub-id-type="doi">10.1080/14992027.2020.1811407</pub-id>.<pub-id pub-id-type="pmid">32924674</pub-id>
</mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Fu</surname><given-names>S</given-names></name>, <name><surname>Huang</surname><given-names>L</given-names></name>, <name><surname>Zhong</surname><given-names>X</given-names></name>, <etal/>
<year>2024</year>. <article-title>Association between personal attenuation
rating with types of earplugs and noise exposure levels in a textile factory
in China</article-title>. <source>Int J. Audiol</source>
<volume>10</volume>:<fpage>1</fpage>&#x02013;<lpage>7</lpage>. DOI: <pub-id pub-id-type="doi">10.1080/14992027.2024.2396028</pub-id>.</mixed-citation></ref><ref id="R10"><mixed-citation publication-type="journal"><collab>GBD 2019 Hearing Loss
Collaborators</collab>. <year>2021</year>. <article-title>Hearing loss
prevalence and years lived with disability, 1990&#x02013;2019: findings from
the Global Burden of Disease Study 2019</article-title>.
<source>Lancet</source>.
<volume>397</volume>(<issue>10278</issue>):<fpage>996</fpage>&#x02013;<lpage>1009</lpage>.
DOI: <pub-id pub-id-type="doi">10.1016/S0140-6736(21)00516-X</pub-id>.<pub-id pub-id-type="pmid">33714390</pub-id>
</mixed-citation></ref><ref id="R11"><mixed-citation publication-type="journal"><name><surname>Gong</surname><given-names>W</given-names></name>, <name><surname>Liu</surname><given-names>X</given-names></name>, <name><surname>Liu</surname><given-names>Y</given-names></name>, <etal/>
<year>2019</year>. <article-title>Evaluating the effect of training along with
fit testing on foam earplug users in four factories in
China</article-title>. <source>Int J Audiol</source>.
<volume>58</volume>(<issue>5</issue>):<fpage>269</fpage>&#x02013;<lpage>277</lpage>.
DOI: <pub-id pub-id-type="doi">10.1016/S0140-6736(21)00516-X</pub-id>.<pub-id pub-id-type="pmid">30880506</pub-id>
</mixed-citation></ref><ref id="R12"><mixed-citation publication-type="journal"><name><surname>Gong</surname><given-names>W</given-names></name>, <name><surname>Zhang</surname><given-names>J</given-names></name>, <name><surname>Liu</surname><given-names>X</given-names></name>, <name><surname>Ding</surname><given-names>E</given-names></name>, <name><surname>Zhu</surname><given-names>B</given-names></name>. <year>2021</year>. <article-title>Verifying earplug attenuation and
evaluating the effectiveness of one-on-one training along with earplug fit
testing at nine facilities in China</article-title>. <source>Am J Ind Med</source>.
<volume>64</volume>(<issue>9</issue>):<fpage>771</fpage>&#x02013;<lpage>780</lpage>.
DOI: <pub-id pub-id-type="doi">10.1002/ajim.23270</pub-id>.<pub-id pub-id-type="pmid">34250617</pub-id>
</mixed-citation></ref><ref id="R13"><mixed-citation publication-type="journal"><name><surname>Haile</surname><given-names>LM</given-names></name>, <name><surname>Orji</surname><given-names>AU</given-names></name>, <name><surname>Reavis</surname><given-names>KM</given-names></name>, <etal/>
<collab>GBD 2019 USA Hearing Loss Collaborators</collab>. <year>2024</year>.
<article-title>Hearing loss prevalence, years lived with disability, and
hearing aid use in the United States from 1990 to 2019: Findings from the
Global Burden of Disease Study</article-title>. <source>Ear Hear</source>.
<volume>45</volume>(<issue>1</issue>):<fpage>257</fpage>&#x02013;<lpage>267</lpage>.
DOI: <pub-id pub-id-type="doi">10.1097/AUD.0000000000001420</pub-id>.<pub-id pub-id-type="pmid">37712826</pub-id>
</mixed-citation></ref><ref id="R14"><mixed-citation publication-type="journal"><name><surname>Hayes</surname><given-names>ME</given-names></name>, <name><surname>Hammond</surname><given-names>S</given-names></name>, <name><surname>Montgomery</surname><given-names>AP</given-names></name>, <etal/>
<year>2022</year>. <article-title>Improving hearing protection device noise
attenuation through fit testing in an occupational health
clinic</article-title>. <source>Workplace Health Saf</source>.
<volume>70</volume>(<issue>4</issue>):<fpage>196</fpage>&#x02013;<lpage>204</lpage>.
DOI: <pub-id pub-id-type="doi">10.1177/21650799211067927</pub-id>.<pub-id pub-id-type="pmid">35353017</pub-id>
</mixed-citation></ref><ref id="R15"><mixed-citation publication-type="book"><collab>ISO 2018. International Organization
for Standardization</collab>. <part-title>Acoustics - Hearing Protectors
- Part 1: subjective method for the measurement of sound
attenuation</part-title>. <source>ISO 4869&#x02013;1:2018</source>.
<publisher-loc>Geneva, Switzerland</publisher-loc>:
<publisher-name>ISO</publisher-name>, <year>2018</year>.</mixed-citation></ref><ref id="R16"><mixed-citation publication-type="journal"><name><surname>Khan</surname><given-names>KS</given-names></name>, <name><surname>Kunz</surname><given-names>R</given-names></name>, <name><surname>Kleijnen</surname><given-names>J</given-names></name>, <name><surname>Antes</surname><given-names>G</given-names></name>. <year>2003</year>. <article-title>Five steps to conducting a systematic
review</article-title>. <source>J R Soc Med</source>.
<volume>96</volume>(<issue>03</issue>):<fpage>118</fpage>&#x02013;<lpage>121</lpage>.
DOI: <pub-id pub-id-type="doi">10.1177/014107680309600304</pub-id>.<pub-id pub-id-type="pmid">12612111</pub-id>
</mixed-citation></ref><ref id="R17"><mixed-citation publication-type="journal"><name><surname>Kerns</surname><given-names>E</given-names></name>, <name><surname>Masterson</surname><given-names>EA</given-names></name>, <name><surname>Themann</surname><given-names>CL</given-names></name>, <name><surname>Calvert</surname><given-names>GM</given-names></name>. <year>2018</year>. <article-title>Cardiovascular conditions, hearing
difficulty, and occupational noise exposure within U.S. industries and
occupations</article-title>. <source>Am J Ind Med</source>.
<volume>61</volume>:<fpage>477</fpage>&#x02013;<lpage>491</lpage>. DOI:
<pub-id pub-id-type="doi">10.1002/ajim.22833</pub-id>.<pub-id pub-id-type="pmid">29537072</pub-id>
</mixed-citation></ref><ref id="R18"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>JW</given-names></name>, <name><surname>Yang</surname><given-names>S</given-names></name>, <name><surname>Chung</surname><given-names>I</given-names></name>, <name><surname>Lee</surname><given-names>MY</given-names></name>. <year>2019</year>. <article-title>The effect of earplug training on
noise protection</article-title>. <source>Ann Occup Environ Med</source>.
<volume>31</volume>:<fpage>e34</fpage>. DOI: <pub-id pub-id-type="doi">10.35371/aoem.2019.31.e34</pub-id>.<pub-id pub-id-type="pmid">31915525</pub-id>
</mixed-citation></ref><ref id="R19"><mixed-citation publication-type="journal"><name><surname>Kulinski</surname><given-names>D</given-names></name>, <name><surname>Murphy</surname><given-names>S</given-names></name>, <name><surname>Mancini</surname><given-names>J</given-names></name>, <etal/>
<year>2024</year>. <article-title>Evaluation of hearing conservation
in-processing procedures at a US marine corps accession
point</article-title>. <source>Perspectives of the ASHA Special Interest Groups</source>.
<volume>9</volume>(<issue>6</issue>):<fpage>1683</fpage>&#x02013;<lpage>1690</lpage>.
DOI: <pub-id pub-id-type="doi">10.1044/2024_PERSP-24-00125</pub-id>.</mixed-citation></ref><ref id="R20"><mixed-citation publication-type="journal"><name><surname>Lempert</surname><given-names>BL</given-names></name>, <name><surname>Edwards</surname><given-names>RG</given-names></name>. <year>1983</year>. <article-title>Field investigations of noise
reduction afforded by insert-type hearing protectors</article-title>.
<source>Am Ind Hyg Assoc J</source>.
<volume>44</volume>(<issue>12</issue>):<fpage>894</fpage>&#x02013;<lpage>902</lpage>.
DOI: <pub-id pub-id-type="doi">10.1080/15298668391405913</pub-id>.<pub-id pub-id-type="pmid">6660189</pub-id>
</mixed-citation></ref><ref id="R21"><mixed-citation publication-type="journal"><name><surname>Le</surname><given-names>TN</given-names></name>, <name><surname>Straatman</surname><given-names>LV</given-names></name>, <name><surname>Lea</surname><given-names>J</given-names></name>, <name><surname>Westerberg</surname><given-names>B</given-names></name>. <year>2017</year>. <article-title>Current insights in noise-induced
hearing loss: A literature review of the underlying mechanism,
pathophysiology, asymmetry, and management options</article-title>.
<source>J Otolaryngol Head Neck Surg</source>.
<volume>46</volume>(<issue>1</issue>):<fpage>41</fpage>. DOI: <pub-id pub-id-type="doi">10.1186/s40463-017-0219-x</pub-id>.<pub-id pub-id-type="pmid">28535812</pub-id>
</mixed-citation></ref><ref id="R22"><mixed-citation publication-type="journal"><name><surname>Liu</surname><given-names>C</given-names></name>, <name><surname>He</surname><given-names>L</given-names></name>, <name><surname>Shan</surname><given-names>X</given-names></name>, <etal/>
<year>2024</year>. <article-title>The burden of occupational noise-induced
hearing loss from 1990 to 2019: an analysis of global burden of disease
data</article-title>. <source>Ear Hear</source>.
<volume>45</volume>(<issue>5</issue>):<fpage>1138</fpage>&#x02013;<lpage>1148</lpage>.
DOI: <pub-id pub-id-type="doi">10.1097/AUD.0000000000001505</pub-id>.<pub-id pub-id-type="pmid">38616317</pub-id>
</mixed-citation></ref><ref id="R23"><mixed-citation publication-type="journal"><name><surname>Liu</surname><given-names>J</given-names></name>, <name><surname>Wang</surname><given-names>X</given-names></name>, <name><surname>Zhang</surname><given-names>R</given-names></name>, <etal/>
<year>2024</year>. <article-title>Measurement and evaluation of personal
attenuation rating before and after the training of the noise-exposed
workers wearing foam earplugs</article-title>.. <source>Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi</source>.
<volume>42</volume>(<issue>8</issue>):<fpage>589</fpage>&#x02013;<lpage>593</lpage>.
Chinese. DOI: <pub-id pub-id-type="doi">10.3760/cma.j.cn121094-20230817-000</pub-id>.<pub-id pub-id-type="pmid">39223044</pub-id>
</mixed-citation></ref><ref id="R24"><mixed-citation publication-type="journal"><name><surname>Liu</surname><given-names>Y</given-names></name>, <name><surname>Yang</surname><given-names>M</given-names></name>. <year>2018</year>. <article-title>Evaluating the effect of training
along with fit testing on earmuff users in a Chinese textile
factory</article-title>. <source>J Occup Environ Hyg</source>.
<volume>15</volume>(<issue>6</issue>):<fpage>518</fpage>&#x02013;<lpage>526</lpage>.
DOI: <pub-id pub-id-type="doi">10.1080/15459624.2018.1456662</pub-id>.<pub-id pub-id-type="pmid">29580200</pub-id>
</mixed-citation></ref><ref id="R25"><mixed-citation publication-type="journal"><name><surname>L&#x000fc; Lin</surname><given-names>ZJ</given-names></name>, <name><surname>Xu</surname><given-names>Jinping</given-names></name>, <name><surname>Zhao</surname><given-names>Rong</given-names></name>, <name><surname>Gu</surname><given-names>Bei</given-names></name>, <name><surname>Song</surname><given-names>Jingyi</given-names></name>. <year>2022</year>.<article-title>Analysis on factors affecting
protective effects effect of hearing protectors for noise workers in a
printing enterprise</article-title>. <source>Chinese Journal of Industrial Medicine</source>. <volume>35</volume>(<issue>4</issue>):
<fpage>369</fpage>&#x02013;<lpage>371</lpage>. Chinese. DOI: <pub-id pub-id-type="doi">10.13631/j.cnki.zggyyx.2022.04.029</pub-id>.</mixed-citation></ref><ref id="R26"><mixed-citation publication-type="confproc"><name><surname>Martin</surname><given-names>L</given-names></name>, <name><surname>Negrini</surname><given-names>A</given-names></name>, <name><surname>Gaudreau</surname><given-names>MA</given-names></name>, <etal/>
<year>2019</year>. <article-title>Earplug personal attenuation rating (PAR) in
noise-exposed workers: evolution over a five weeks
follow-up</article-title>. <conf-name>Paper presented at: 26th International
congress on sound and vibration</conf-name>
<conf-date>July 7&#x02013;11</conf-date>; <conf-loc>Montreal,
Canada</conf-loc>.</mixed-citation></ref><ref id="R27"><mixed-citation publication-type="book"><name><surname>Morata</surname><given-names>TC</given-names></name>, <name><surname>Gong</surname><given-names>W</given-names></name>, <name><surname>Tikka</surname><given-names>C</given-names></name>, <etal/>
<year>2024</year>. <source>Hearing protection field attenuation estimation systems and associated training for reducing workers&#x02019; exposure to noise</source>. <publisher-name>Cochrane Database of Systematic Reviews
2024, Issue 5</publisher-name>. Art. No.: CD015066. DOI: <pub-id pub-id-type="doi">10.1002/14651858.CD015066.pub2</pub-id>.</mixed-citation></ref><ref id="R28"><mixed-citation publication-type="journal"><name><surname>Munn</surname><given-names>Z</given-names></name>, <name><surname>Peters</surname><given-names>MDJ</given-names></name>, <name><surname>Stern</surname><given-names>C</given-names></name>, <name><surname>Tufanaru</surname><given-names>C</given-names></name>, <name><surname>McArthur</surname><given-names>A</given-names></name>, <name><surname>Aromataris</surname><given-names>E</given-names></name>. <year>2018</year>. <article-title>Systematic review or scoping review?
Guidance for authors when choosing between a systematic or scoping review
approach</article-title>. <source>BMC Med Res Methodol</source>.
<volume>18</volume>(<issue>01</issue>):<fpage>143</fpage>. DOI: <pub-id pub-id-type="doi">10.1186/s12874-018-0611-x</pub-id>.<pub-id pub-id-type="pmid">30453902</pub-id>
</mixed-citation></ref><ref id="R29"><mixed-citation publication-type="journal"><name><surname>Murphy</surname><given-names>WJ</given-names></name>, <name><surname>Themann</surname><given-names>CL</given-names></name>, <name><surname>Murata</surname><given-names>TK</given-names></name>. <year>2016</year>. <article-title>Hearing protector fit testing with
off-shore oil-rig inspectors in Louisiana and Texas</article-title>.
<source>Int J Audiol</source>.
<volume>55</volume>(<issue>11</issue>):<fpage>688</fpage>&#x02013;<lpage>698</lpage>.
DOI: <pub-id pub-id-type="doi">10.1080/14992027.2016.1204470</pub-id>.<pub-id pub-id-type="pmid">27414471</pub-id>
</mixed-citation></ref><ref id="R30"><mixed-citation publication-type="journal"><name><surname>Murphy</surname><given-names>WJ</given-names></name>, <name><surname>Flamme</surname><given-names>GA</given-names></name>, <name><surname>Vause</surname><given-names>NL</given-names></name>
<year>2023</year>. <article-title>Overcoming barriers to hearing protector fit
testing&#x02013;outcomes of the international hearing protector fit-testing
symposium</article-title>. <source>Proce Mtgs Acoust</source>.
<volume>53</volume>(<issue>1</issue>):<fpage>002005</fpage>. DOI: <pub-id pub-id-type="doi">10.1121/2.0001936</pub-id>.</mixed-citation></ref><ref id="R31"><mixed-citation publication-type="journal"><name><surname>Neitzel</surname><given-names>RL</given-names></name> and <name><surname>Seixas</surname><given-names>N</given-names></name>. <year>2005</year>. <article-title>The effectiveness of hearing
protection among construction workers</article-title>. <source>J. Occup. Environ Hyg</source>
<volume>2</volume>(<issue>4</issue>):<fpage>227</fpage>&#x02013;<lpage>238</lpage>.
DOI: <pub-id pub-id-type="doi">10.1080/15459620590932154</pub-id>.<pub-id pub-id-type="pmid">15788384</pub-id>
</mixed-citation></ref><ref id="R32"><mixed-citation publication-type="journal"><name><surname>Nelson</surname><given-names>DI</given-names></name>, <name><surname>Nelson</surname><given-names>RY</given-names></name>, <name><surname>Concha-Barrientos</surname><given-names>M</given-names></name>, <name><surname>Fingerhut</surname><given-names>M</given-names></name>. <year>2005</year>. <article-title>The global burden of occupational
noise-induced hearing loss</article-title>. <source>Am J Ind Med</source>.
<volume>48</volume>(<issue>6</issue>):<fpage>446</fpage>&#x02013;<lpage>458</lpage>.
DOI: <pub-id pub-id-type="doi">10.1002/ajim.20223</pub-id>.<pub-id pub-id-type="pmid">16299704</pub-id>
</mixed-citation></ref><ref id="R33"><mixed-citation publication-type="journal"><name><surname>Neyeloff</surname><given-names>JL</given-names></name>, <name><surname>Fuchs</surname><given-names>SC</given-names></name>, <name><surname>Moreira</surname><given-names>LB</given-names></name>
<year>2012</year>. <article-title>Meta-analyses and Forest plots using a
Microsoft excel spreadsheet: step-by-step guide focusing on descriptive data
analysis</article-title>. <source>BMC research notes</source>.
<volume>5</volume>:<fpage>52</fpage>. DOI: <pub-id pub-id-type="doi">10.1186/1756-0500-5-52</pub-id>.<pub-id pub-id-type="pmid">22264277</pub-id>
</mixed-citation></ref><ref id="R34"><mixed-citation publication-type="journal"><name><surname>Park</surname><given-names>MY</given-names></name>, <name><surname>Casali</surname><given-names>JG</given-names></name>
<year>1991</year>. <article-title>A controlled investigation of in-field
attenuation performance of selected insert, earmuff, and canal cap hearing
protectors</article-title>. <source>Human factors</source>.
<volume>33</volume>(<issue>6</issue>):<fpage>693</fpage>&#x02013;<lpage>714</lpage>.
DOI: <pub-id pub-id-type="doi">10.1177/001872089103300606</pub-id>.<pub-id pub-id-type="pmid">1800294</pub-id>
</mixed-citation></ref><ref id="R35"><mixed-citation publication-type="journal"><name><surname>Sayler</surname><given-names>SK</given-names></name>, <name><surname>Rabinowitz</surname><given-names>PM</given-names></name>, <name><surname>Cantley</surname><given-names>LF</given-names></name>, <name><surname>Galusha</surname><given-names>D</given-names></name>, and <name><surname>Neitzel</surname><given-names>RL</given-names></name>. <year>2018</year>. <article-title>Costs and effectiveness of hearing
conservation programs at 14 US metal manufacturing
facilities</article-title>. <source>Int. J. Aud</source>
<volume>57</volume>(<issue>sup1</issue>):<fpage>S3</fpage>&#x02013;<lpage>S11</lpage>.
DOI: <pub-id pub-id-type="doi">10.1080/14992027.2017.1410237</pub-id>.</mixed-citation></ref><ref id="R36"><mixed-citation publication-type="book"><name><surname>Sch&#x000fc;nemann</surname><given-names>H</given-names></name>, <name><surname>Bro&#x0017c;ek</surname><given-names>J</given-names></name>, <name><surname>Guyatt</surname><given-names>G</given-names></name>, <name><surname>Oxman</surname><given-names>A</given-names></name>, editors. <year>2013</year>. <source>GRADE handbook for grading quality of evidence and strength of recommendations</source>. <publisher-name>The
GRADE Working Group</publisher-name>, Updated October 2013. Available from
<ext-link xlink:href="http://guidelinedevelopment.org/handbook" ext-link-type="uri">guidelinedevelopment.org/handbook</ext-link>.</mixed-citation></ref><ref id="R37"><mixed-citation publication-type="journal"><name><surname>Shi</surname><given-names>HX</given-names></name>, <name><surname>Su</surname><given-names>SB</given-names></name>, <name><surname>Liu</surname><given-names>M</given-names></name>, <etal/>
<year>2023</year>. <article-title>Analysis of verification results of protective
effects of hearing protectors in different industries</article-title>.
<source>Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi</source>.
<volume>41</volume>(<issue>5</issue>):<fpage>333</fpage>&#x02013;<lpage>337</lpage>.
Chinese. DOI: <pub-id pub-id-type="doi">10.3760/cma.j.cn121094-20211026-00516</pub-id>.<pub-id pub-id-type="pmid">37248077</pub-id>
</mixed-citation></ref><ref id="R38"><mixed-citation publication-type="journal"><name><surname>Shu</surname><given-names>L</given-names></name>, <name><surname>Fan</surname><given-names>Z</given-names></name>, <name><surname>Tang</surname><given-names>J</given-names></name>, <etal/>
<year>2025</year>. <article-title>The protective effect of wearing hearing
protection devices in noise-induced hearing loss and its potential
influencing factors in the Chinese adult population</article-title>.
<source>Sci Total Environ</source>.
<volume>964</volume>:<fpage>178507</fpage>. DOI: <pub-id pub-id-type="doi">10.1016/j.scitotenv.2025.178507</pub-id>.<pub-id pub-id-type="pmid">39869967</pub-id>
</mixed-citation></ref><ref id="R39"><mixed-citation publication-type="book"><name><surname>Sterne</surname><given-names>JAC</given-names></name>, <name><surname>Hern&#x000e1;n</surname><given-names>MA</given-names></name>, <name><surname>McAleenan</surname><given-names>A</given-names></name>, <name><surname>Reeves</surname><given-names>BC</given-names></name>, <name><surname>Higgins</surname><given-names>JPT</given-names></name>. <part-title>Chapter 25: Assessing risk of bias in a non-randomized
study</part-title> [last updated October 2019]. In: <name><surname>Higgins</surname><given-names>JPT</given-names></name>, <name><surname>Thomas</surname><given-names>J</given-names></name>, <name><surname>Chandler</surname><given-names>J</given-names></name>, <name><surname>Cumpston</surname><given-names>M</given-names></name>, <name><surname>Li</surname><given-names>T</given-names></name>, <name><surname>Page</surname><given-names>MJ</given-names></name>, <name><surname>Welch</surname><given-names>VA</given-names></name> (editors). <source>Cochrane Handbook for Systematic Reviews of Interventions version 6.5</source>.
<publisher-name>Cochrane</publisher-name>, <year>2024</year>. Available from
<ext-link xlink:href="http://www.training.cochrane.org/handbook" ext-link-type="uri">www.training.cochrane.org/handbook</ext-link>.</mixed-citation></ref><ref id="R40"><mixed-citation publication-type="journal"><name><surname>Tikka</surname><given-names>C</given-names></name>, <name><surname>Verbeek</surname><given-names>JH</given-names></name>, <name><surname>Kateman</surname><given-names>E</given-names></name>, <etal/>
<year>2017</year>. <article-title>Interventions to prevent occupational
noise-induced hearing loss</article-title>. <source>Cochrane Database of Systematic Reviews</source>, Issue <issue>7</issue>. Art. No: CD006396. DOI:
<pub-id pub-id-type="doi">10.1002/14651858.CD006396.pub4</pub-id>.</mixed-citation></ref><ref id="R41"><mixed-citation publication-type="journal"><name><surname>Themann</surname><given-names>CL</given-names></name>, <name><surname>Masterson</surname><given-names>EA</given-names></name>. <year>2019</year>. <article-title>Occupational noise exposure: A review
of its effects, epidemiology, and impact with recommendations for reducing
its burden</article-title>. <source>J Acoust Soc Am</source>.
<volume>146</volume>(<issue>5</issue>):<fpage>3879</fpage>&#x02013;<lpage>3805</lpage>.
DOI: <pub-id pub-id-type="doi">10.1121/1.5134465</pub-id>.<pub-id pub-id-type="pmid">31795665</pub-id>
</mixed-citation></ref><ref id="R42"><mixed-citation publication-type="journal"><name><surname>Themann</surname><given-names>CL</given-names></name>, <name><surname>Masterson</surname><given-names>EA</given-names></name>, <name><surname>Peterson</surname><given-names>JS</given-names></name>, <name><surname>Murphy</surname><given-names>WJ</given-names></name>. <year>2023</year>. <article-title>Preventing occupational hearing loss:
50 years of research and recommendations from the National Institute for
Occupational Safety and Health</article-title>. <source>Semin Hear</source>.
<volume>44</volume>(<issue>4</issue>):<fpage>351</fpage>&#x02013;<lpage>393</lpage>.
DOI: <pub-id pub-id-type="doi">10.1055/s-0043-1769499</pub-id>.<pub-id pub-id-type="pmid">37818146</pub-id>
</mixed-citation></ref><ref id="R43"><mixed-citation publication-type="journal"><name><surname>Takada</surname><given-names>MM</given-names></name>, <name><surname>Rocha</surname><given-names>CH</given-names></name>, <name><surname>Neves-Lobo</surname><given-names>IF</given-names></name>, <etal/>
<year>2020</year>. <article-title>Training in the proper use of earplugs: An
objective evaluation</article-title>. <source>Work</source>.
<volume>65</volume>(<issue>2</issue>):<fpage>40</fpage>&#x02013;<lpage>407</lpage>.
DOI: <pub-id pub-id-type="doi">10.3233/WOR-203092</pub-id>.</mixed-citation></ref><ref id="R44"><mixed-citation publication-type="journal"><name><surname>Tsukada</surname><given-names>T</given-names></name>, <name><surname>Sakakibara</surname><given-names>H</given-names></name>. <year>2008</year>. <article-title>A trail of individual education for
hearing protection with an instrument that measures the noise attenuation
effect of wearing earplugs</article-title>. <source>Ind Health</source>.
<volume>46</volume>(<issue>4</issue>):<fpage>393</fpage>&#x02013;<lpage>396</lpage>.
DOI: <pub-id pub-id-type="doi">10.2486/indhealth.46.393</pub-id>.<pub-id pub-id-type="pmid">18716388</pub-id>
</mixed-citation></ref><ref id="R45"><mixed-citation publication-type="book"><name><surname>Voix</surname><given-names>J</given-names></name>, <name><surname>Smith</surname><given-names>P</given-names></name>, <name><surname>Berger</surname><given-names>EH</given-names></name>. <year>2022</year>. <part-title>Field fit testing and
attenuation-estimation procedure</part-title>. In: <name><surname>Meinke</surname><given-names>DK</given-names></name>, <name><surname>Berger</surname><given-names>EH</given-names></name>, <name><surname>Neitzel</surname><given-names>RL</given-names></name>, <name><surname>Driscoll</surname><given-names>DP</given-names></name>, <name><surname>Bright</surname><given-names>K</given-names></name>, editors(s). <source>The Noise Manual</source>. <edition>6th
edition</edition>. <publisher-loc>Fairfax (VA)</publisher-loc>:
<publisher-name>American Industrial Hygiene Association
(AIHA)</publisher-name>, 2022:<fpage>255</fpage>&#x02013;<lpage>301</lpage>.
[ISBN: 978-1-935082-98-9].</mixed-citation></ref><ref id="R46"><mixed-citation publication-type="journal"><name><surname>Wan</surname><given-names>X</given-names></name>, <name><surname>Wang</surname><given-names>W</given-names></name>, <name><surname>Liu</surname><given-names>J</given-names></name>
<etal/>
<year>2014</year>. <article-title>Estimating the sample mean and standard
deviation from the sample size, median, range and/or interquartile
range</article-title>. <source>BMC Med Res Methodol</source>.
<volume>14</volume>:<fpage>135</fpage>. DOI: <pub-id pub-id-type="doi">10.1186/1471-2288-14-135</pub-id>.<pub-id pub-id-type="pmid">25524443</pub-id>
</mixed-citation></ref><ref id="R47"><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>YN</given-names></name>, <name><surname>Su</surname><given-names>SB</given-names></name>, <name><surname>Liao</surname><given-names>CH</given-names></name>, <etal/>
<year>2024</year>. <article-title>Study on the fit testing for the workers
wearing hearing protection device in machinery manufacturing
enterprises</article-title>. <source>Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi</source>.
<volume>42</volume>(<issue>1</issue>):<fpage>16</fpage>&#x02013;<lpage>21</lpage>.
Chinese. DOI: <pub-id pub-id-type="doi">10.3760/cma.j.cn121094-20220909-00451</pub-id>.<pub-id pub-id-type="pmid">38311944</pub-id>
</mixed-citation></ref><ref id="R48"><mixed-citation publication-type="journal"><name><surname>Wells</surname><given-names>LL</given-names></name>, <name><surname>Schulz</surname><given-names>TY</given-names></name>, <name><surname>Saleem</surname><given-names>M</given-names></name>, <name><surname>Dantscher</surname><given-names>S</given-names></name>, <name><surname>Borst</surname><given-names>B</given-names></name>, <etal/>
<year>2023</year>. <article-title>Standards and Regulations for Hearing
Protector Fit Testing &#x02013; Outcomes of the International Hearing
Protector Fit-Testing Symposium</article-title>. <source>Proc. Mtgs. Acoust</source>
<volume>53</volume>(<issue>1</issue>):<fpage>002001</fpage>. DOI:<pub-id pub-id-type="doi">10.1121/2.0001843</pub-id>.</mixed-citation></ref><ref id="R49"><mixed-citation publication-type="journal"><name><surname>Zhong</surname><given-names>X</given-names></name>, <name><surname>Fu</surname><given-names>SJ</given-names></name>, <name><surname>Zhu</surname><given-names>JW</given-names></name>, <etal/>
<year>2023</year>. <article-title>Research on the protective effect of hearing
protective device for workers exposed to noise in a motor manufacturing
enterprise</article-title>. <source>Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi</source>. <volume>41</volume>(<issue>11</issue>):
<fpage>814</fpage>&#x02013;<lpage>818</lpage>. Chinese. DOI: <pub-id pub-id-type="doi">10.3760/cma.j.cn121094-20220815-00402</pub-id>.</mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Figure 1.</label><caption><p id="P63">Prisma flowchart for screening process conducted for the mixed method
review.</p></caption><graphic xlink:href="nihms-2143323-f0001" position="float"/></fig><fig position="float" id="F2"><label>Figure 2.</label><caption><p id="P64">Mean differences in personal attenuation rating (PAR) values between
results of the pre-intervention PARs without instruction and post-intervention
PARs with extensive instruction at immediate, short-term, and long-term retests.
The larger solid triangles represent the overall effect for each timeframe and
the small open triangles indicate the effect for individual studies.</p></caption><graphic xlink:href="nihms-2143323-f0002" position="float"/></fig><fig position="float" id="F3"><label>Figure 3.</label><caption><p id="P65">Mean differences in personal attenuation rating (PAR) values between
results of the follow-up test with or without refresher training and that of
retest immediately after extensive instructions. The large solid triangles
represent the overall effect for each timeframe and the small open triangles
indicate the effect for individual studies.</p></caption><graphic xlink:href="nihms-2143323-f0003" position="float"/></fig></floats-group></article>