The aim of this study was to measure permeation of the herbicide dichlobenil in Casoron 4G through disposable and chemically protective nitrile gloves using an American Society for Testing and Materials-type permeation cell and a closed-loop system employing two different solvents (hexane and water) and two different challenge situations (aqueous emulsion and solid formulation). Capillary gas chromatography–mass spectrometry was used for quantification purposes. The chemically protective glove did not allow any permeation up to 8 h for the solid-formulation and water-collection challenges, but permeation was detected in all other challenges. The disposable glove allowed the most permeation, and the solid-formulation challenge with water collection necessitated that a dichlobenil equivalent be calculated because of the presence of its hydrolysis degradation product 2,6-dichlorobenzamide. Permeation from the solid formulation was detectable by hexane collection for both the disposable and chemically protective gloves and by water collection for the disposable glove. It was concluded that hexane-solvent collection was not valid for the disposable glove at 4 and 8 h of permeation in the solid Casoron challenge or for the aqueous emulsion challenge at 8 h relative to the water-collection solvent data. The hexane-solvent collection for the chemically protective glove was valid for the 8-h solid-formulation challenge but not for the 8-h aqueous-solution challenge. All water-solvent collections were valid; however, dichlobenil usually permeated the gloves.
Dichlobenil (2,6-dichlorobenzonitrile; Chemical Abstracts Service RN 1194-65-6) is a nonselective systemic soil herbicide applied for pre- and post-emergence weed control in many fruits and flowers as well as in slow-flowing aquatic systems (Hazardous Substances Data Bank
No scientific literature has been published on the permeation of dichlobenil through glove materials, which are the chief mode of protection of hand skin. A common message in many material safety data sheets for formulations containing dichlobenil, without specifying the glove material, is to “use chemical resistant protective gloves,” “wear suitable protective equipment,” or “wear protective clothing.” Regarding the emulsifiable concentrates of pesticides, i.e., Casoron CS for dichlobenil, handling, spraying, and formulating the liquid concentrate are probably the most hazardous operations because many chemicals are involved at high concentrations in often quasi-confined unventilated spaces. Worker field re-entry to wet foliage and soil after spraying is another hazardous scenario that has generally been mitigated by respecting the correct re-entry interval. Many pesticides are available in dust form, e.g., Casoron G, G-2, G-4, and 4G for dichlobenil; thus, inhalation protection for particulates may also be needed. We provide here the first reported quantitative permeation of dichlobenil through specific glove materials.
Casoron 4G (4.0% dichlobenil) came from Chemtura (Middlebury, CT). The granular formulation also contained an unspecified thickening agent and a proprietary carrier at unspecified concentrations. The recommended application range is 50–300 lb/acre (56–340 kg/ha); the re-entry interval is 12 h. Pure dichlobenil (99.5% purity nominally), 2,6-dichlorobenzamide (99% purity nominally), and internal standard (IS) 4,4’-dichlorobiphenyl (99%) were obtained from ChemService (West Chester, PA). Optima-grade hexanes (hereafter called hexane) and isopropanol came from Fisher Scientific (Pittsburgh, PA). All water was Millipore triple-cartridge deionized.
Safeskin nitrile powder-free examination gloves (24.1-cm length, unspecified thickness, no. N330; Kimberly Clark, San Diego, CA) were obtained from Fisher Scientific. Solvex unsupported and unlined nitrile chemical protective gloves (33-cm length, 11-mil thickness, No. 37-145) came from Ansell Occupational Healthcare (Coshocton, OH).
A calibrated Marathon electronic digital micrometer (model No. CO 030025, 0–25 mm range, 0.001 mm resolution; Fisher) was used to measure glove thickness before and after permeation testing. A calibrated Mettler analytic balance delta range (model No. AE260; Mettler, Hightstown, NJ) was used to weigh gloves before and after permeation.
Infrared (IR) spectra were obtained with an Avatar 360 Fourier-transform (FT) spectrophotometer system (ThermoNicolet, Madison, WI) and a single-beam FT-IR spectrophotometer using the reflectance mode and operated with OMNIC 6.0a software. The crystal was diamond in single-reflection horizontal attenuated total reflectance mode. The spectral range was 4,000–600 cm−1, and the number of scans was 64.
Gas chromatography–mass spectrometry (GC–MS) was performed with an Agilent 6890 N network gas chromatograph (Agilent Technologies, Wilmington, DE) connected to an Agilent 5973 network mass selective detector (MSD). The MSD was a quadrupole with an electron multiplier detector. The GC column was an HP 5-MS 30 m × 0.25 mm i.d. (0.25-μm film) fused silica capillary column (Agilent). The helium carrier flow (99.9999%; Air Liquide, Long Beach, CA) was 3.00 ± 0.20 mL/min. The temperature of the injector was 200°C and that of the transfer line was 280°C. The 70-eV ion source and the quadrupole were held at 230º and 150°C, respectively.
A mass of 10 mg dichlobenil was mixed with 20 mL water in a brown centrifuge tube in triplicate. Each sample was sonicated at 40°C for 60 min with the screw cap on. After cooling to 22.5°C, the solution was centrifuged at 900 g for 30 min; 0.2 mL of the supernatant fraction was transferred to a 4-mL vial; this was extracted consecutively with 0.4, 0.3, and 0.3 mL hexane; and the extracts were combined for analysis. The IS 4,4’-dichlorobiphenyl in hexane was added to a final concentration of 0.5 ng/mL. The amount of dichlobenil was determined by GC–MS using the IS method (see later text). The solubility was then calculated. A similar procedure was performed to determine dichlobenil solubility in hexane.
A 2 mg/mL solution of Casoron 4G was prepared separately in hexane, isopropanol, and water. A subvolume of 0.1 mL was then diluted to 1 mL with hexane and isopropanol, as appropriate, for direct analysis by the IS method (see later text). The 0.1-mL water solution was brought just to dryness in a stream of nitrogen and dissolved to produce 1 mL isopropanol solution for GC–MS analysis (see later text).
Aqueous solutions containing 1 g Casoron 4G in 25 mL volumetric flasks were also sonicated for 1 h at 40°C and filtered the next day. Then 0.1 mL filtrate was evaporated as previously described. The residue was dissolved in isopropanol and then analyzed using the total ion current mode (
The permeation procedure was based on a modified American Society for Testing and Materials (ASTM) F739-99a permeation method (
Each circular piece was then held between the two Teflon gaskets/Pyrex chambers of an I-PTC-600 ASTM-type permeation cell (Pesce Laboratory, Kennett Square, PA) by a uniform torque with the outer surface of the glove facing the challenge chamber. The exposed glove material between the two chambers was 25.4 mm in diameter. A 10-mL volume of aqueous emulsion at a concentration of 2.0 mg/mL was pipetted into the challenge chamber, and 10 mL solvent (hexane or water) was pipetted into the collection chamber. Solid Casoron 4G powder (8.500 g) was placed in the challenge side for some challenges.
The permeation cells were clamped and immersed six at a time in a Fisher shaking water bath (model 127) at 35.0°C ± 0.5°C so that the test material in each cell was vertical. The permeation cells were agitated for 8 h at an average horizontal shaking speed of 70 ± 5 cycles/min; the traveling distance was 10.24 cm/cycle. This assured that the emulsion did not stratify, that the collection side did not build up concentration gradients, and that the test material was wetted continuously on both sides. The collection solvent and the challenge solution were then weighed. The permeation cells were disassembled, and the outer surfaces of glove pieces were blotted dry with Kimwipes. The glove pieces were reconditioned in a desiccator for 24 h before final weight, thickness, and IR reflectance measurements were taken.
Solvent blank tests with 10 mL solvent in the collection chamber, with only air in the challenge chamber, were also performed. Information on back-permeation of the collection chamber solvent was obtained by injecting challenge-chamber air samples in gas-tight syringes into the GC–MS. All tests were performed at least in triplicate.
The collection and challenge aqueous solutions were evaporated just to dryness under a flow of nitrogen at 40°C in a volumetric tube. A volume of 50 μL 100 μg/mL 4,4’-dichlorobiphenyl IS in hexane was added, and hexane was added to a final volume of 1.0 mL. A 2-μL aliquot was injected into the GC–MS for analysis. The final IS concentration in the injection was 0.5 μg/mL.
The MS detected ions of mass-to-charge ratio (
Ratios of dichlobenil area for
FT reflectance IR scan analysis of the dry glove materials was performed from 4,000 to 600 cm−1. The major reflectance maxima for dichlobenil at 782, 1198, and 1431 cm−1 and those for 2,6-dichlorobenzamide at 1643 and 787 cm−1 were scrutinized.
The GC–MS linear range for dichlobenil using
The water-solubility triplicate results were 20.4, 18.9, and 23.1 mg/L to provide an arithmetic mean and SD of 20.8 ± 2.1 mg/L at 22.5°C. The literature solubility value at 20°C is 18 mg/L (Hazardous Substances Data Bank
The experiment to test the stability of Casoron 4G in hexane and isopropanol resulted in no degradation to the amide. The water solution, analyzed when fresh, also showed no degradation, but the solution that was ultrasonicated at 40°C for 1 h, left overnight, and processed on day 2 contained hydrolysis products. The chromatogram also showed the presence of lauric anhydride, probably from the pyrolysis of sodium laurate surfactant.
The dichlobenil contents for three replicates were (w/w) 4.1, 4.3, and 3.5%, with an arithmetic mean and SD of 3.97 ± 0.42%. This is not significantly different from the nominal composition of 4.0% at
The results, including the resultant mass/area factor and the calculated linear flux, for the two solvent collection systems and for the two different nitrile glove types are listed in Table Permeation after 8-h dichlobenil exposure from Casoron 4G formulation at 2.0 mg/mL aqueous emulsion in the challenge side of a ASTM-type permeation cell using 10 mL water or hexane as collection solvent for disposable Safeskin or chemically protective Solvex nitrile gloves aAv ± SD is average (arithmetic mean) ± SD Permeation after 8-h dichlobenil exposure from solid Casoron 4G formulation (8.5 g) in the challenge side of a ASTM-type permeation cell using 10 mL water or hexane as collection solvent for disposable Safeskin or chemically protective Solvex nitrile gloves aAv ± SD is average (arithmetic mean) ± SD bComputed from 2,6-dichlorobenzamide and dichlobenil in the collection sideGlove Solvent Replicate mass (ng) Mass/area (ng/cm2) Linear flux (ng/cm2/min) Safeskin Hexane 1 254,000 50,700 106 2 181,000 36,000 75.0 3 199,000 39,700 82.8 Av ± SDa 211,000±38,000 42,100 ± 7600 88 ± 16 Water 1 2.10 0.420 0.000875 2 2.36 0.472 0.000983 3 2.89 0.577 0.00120 Av ± SD 2.45 ± 0.40 0.490 ± 0.080 0.00102 ± 0.00017 Solvex Hexane 1 4.310 861 0.179 2 4.490 899 0.187 3 3.340 668 0.139 Av ± SD 4047 ± 620 810 ± 120 0.168 ± 0.026 Water 1 5.72 1.14 0.00238 2 4.12 0.823 0.00171 3 4.65 0.930 0.00194 Av ± SD 4.83 ± 0.82 0.96 ± 0.16 0.00201 ± 0.00034 Glove Solvent Replicate mass (ng) Mass/area (ng/cm2) Linear flux (ng/cm2/min) Safeskin Hexane 1 642,000 128,000 268 2 1,120,000 225,000 468 3 755,000 151,000 314 Av ± SDa 839,000 ± 250,000b 168,000 ± 51,000 350 ± 100 Water 1 32.3 6.47 0.0135 2 30.0 5.20 0.0108 3 20.4 4.08 0.0085 Av ± SD 27.6 ± 6.3b 5.3 ± 1.2 0.0109 ± 0.0025 Solvex Hexane 1 447 89.4 0.186 2 179 35.8 0.0746 3 369 73.7 0.154 Av ± SD 330 ± 140 66 ± 28 0.138 ± 0.057 Water 1 <3 <0.6 <0.0012 2 <3 <0.6 <0.0012 3 <3 <0.6 <0.0012 Av ± SD <3 <0.6 <0.0012
Table
Table
Our experimental water solubility of dichlobenil of 20.8 mg/L is equivalent to a 10-mL collection solution containing an analyte mass of 208 μg. No water-collection solution contained this amount of dichlobenil at the end of the permeation period, although this volume of water had such a capacity. It is possible that water is so polar that strong adsorption to the glove surface may not render the permeated herbicide available enough for solubilization from the collection side surface. Any tightly adsorbed permeate would decrease the permeation rate through the membrane and produce a negative bias to the observed concentration in water. In addition, glove manufacturer data show that the normalized breakthrough time of hexane for Safeskin is approximately 21 min (Reyes
Another interesting result is that nitrile challenge with dry Casoron 4G powder produces the same generalized results as aqueous emulsion challenges, with higher levels of dichlobenil permeated for Safeskin but not for Solvex gloves. Thus, at 8 h for Safeskin gloves, the ratios for solid-to-aqueous solution dichlobenil ratio data for water and hexane were approximately 11 and 4, respectively. The corresponding data for Solvex gloves are <0.62.and 0.82, respectively, thus reflecting the general protectiveness of Solvex gloves.
The phenomenon of organic solids producing permeation across glove material was first observed by Fricker and Hardy (
Relative to worker risk assessment for dichlobenil exposure, the allowed daily intake of 500 ng/kg body weight (Hazardous Substances Data Bank
Permeation of the herbicide dichlobenil from both concentrated aqueous emulsion and dry solid Casoron 4G through disposable and chemically protective nitrile gloves is reported here for the first time. The permeation results differ with collection solvent, with the amount for water collection being much lower than for hexane collection. The chemically protective glove was permeated the least for each solvent. Hexane was not an adequate collection solvent relative to water for the disposable nitrile glove during 4- or 8-h or for 8-h aqueous emulsion challenges. Hexane solvent was adequate in solid-formulation challenges for the chemically protective glove during 8 h, but not for the 8-h aqueous emulsion challenge. The possible mechanisms to account for the observations were discussed in the previous text.
This project was funded by the UCLA Center for Occupational and Environmental Health and National Institute for Occupational Safety and Health Grant No. OH03754.