Whole glove testing for a metalworking fluid (MWF) in the field was performed for the first time. Green latex gloves used in a machine shop were exposed for 20 min to MWF. The permeated amount (1.0 ± 0.5 μg/cm2) was higher than the threshold (0.25 μg/cm2) for the ASTM F739-99a closed-loop normalized breakthrough time.

KeywordsLatex glovesMetalworking fluidsWhole glove permeationField studyRinse methodissue-copyright-statement© Springer Science+Business Media, LLC 2010

The composition and the adverse health effects of metalworking fluids (MWFs) are well researched (Byers 1994; NIOSH 1998; Xu and Que Hee 2006a). MWFs are complex blended mixtures that not only contain petroleum distillate but also additives. The performance of disposable gloves against MWFs has been tested in the laboratory in permeation cells (Xu and Que Hee 2006b, 2007, 2008a). Only flat material can be examined (ASTM 2004), work factors are not simulated, the test temperature differs from the actual temperature of gloved hands, and whole gloves are not tested (Klingner and Boeniger 2002; ASTM 2004; Phalen and Que Hee 2008). In the present study, the first field study of glove permeation of a MWF, the permeation of whole gloves was investigated in a metalworking shop.

Materials and Methods

The metalworking fluid used was New Rapid Tap from Relton (Arcadia, CA). It contained mineral oil (CAS 64742-58-1, <50% weight), chlorinated paraffins (CAS 61788-76-9, <40%), additives (patent, <8%), epoxidized soybean oil (CAS 8013-07-8, <1%), olefin sulfide (patent, <1%), and cinnamon oil (trace). The glove was DermaThin, a green natural rubber latex glove (Best Manufacturing Company, Menlo, GA). Workers could have gloves as needed. The mass per unit area of three gloves was determined with cut pieces at the palm area. These data and the mass of the whole glove led to an average total outer surface area of 581 ± 16 cm2. The glove thickness was 0.122 ± 0.004 mm, from seven measurements for each of three gloves. The worker operated a Hardinge Super-Precision lathe (Elmira, NY). Most manipulations required both hands. During the metalworking process, the worker held a tin can of Rapid Tap fluid upside down in his right-gloved hand to drip the MWF on the turning metal tube and lathe. MWF mist formed when MWF dripped on the turning tube. The worker then removed the tube from the lathe, and sprayed acetone to clean the tube. A cotton cloth was used to wipe the lathe, and treatment with compressed air and a sand cloth improved the finish. The whole cycle took some 60 min. There was no local exhaust system. A machine guard was available but was flipped open to allow a better view. No respirators were used. The worker first washed his hands with liquid soap before putting on the method blank gloves. The latter were removed after 2 min without touching metal pieces or MWF. Fresh gloves were then donned, and two drops (53 ± 2 mg) of MWF was applied on the palm of the glove. The worker rubbed the palms of the two gloves together, but did not touch the glove on the backs of the hands. The worker did the shop job as indicated above. After 20 min, the investigators, wearing fresh gloves, eased the exposed gloves off the worker’s fingers by gentle pulling, and removed the gloves. The glove cuff was then tied by a rubber band. Throughout the process, care was taken to avoid contamination of the glove inner surface. Each exposed glove was deposited in a labeled acid-washed 50 mL wide mouth Pyrex Mason jar with Teflon lined screw cap. Transfer to the laboratory occurred within 10 min. Three pairs of exposed gloves were obtained in total.

In the laboratory, the glove was taken out of the jar by gloved hands, and the rubber band removed. About 5 mL perfluorohexane (>98.5% purity) from Apollo Scientific, Bredbury, Cheshire, UK (Xu and Que Hee 2006a, 2008b; Phalen and Que Hee 2008) was pipetted into the inside of the glove through the small opening at the glove wrist-end. The opening was then closed, the glove shaken up and down for 10 s, kneaded 15 s to ensure that perfluorohexane wet the entire inner surface, and shaken further for another 5 s. The perfluorohexane was then dripped into a 20 mL acid-washed glass vial with Teflon-lined screw-cap. Five such rinses were done for each glove. Each rinse was analyzed by gas chromatography-mass spectrometry (GC-MS) by the total ion current monitoring mode (m/z 50–400), and using the conditions described elsewhere (Xu and Que Hee 2006a) except for the GC column temperature program. The 30 m × 0.25 mm HP-5 capillary column was held at 150°C for 15 min, heated at 20°C/min to 250°C, and held at 250°C for 13 min. Aliquots of 1.0 μL of each rinse and the standard solutions of 0, 22, 44, 66, 88, and 110 ng/μL of Rapid Tap MWF were injected in perfluorohexane solution. Standard curves were linearized by Box-Cox power transformation (Xu and Que Hee 2006a).

Results and Discussion

The glove fingers and palm area became black from manipulating the work piece and tools, especially on the thumb, index, and middle fingers. The lower quantifiable limit of MWF was 44 ng. The standard curve of GC-MS area versus injected MWF mass had a correlation coefficient (r) of 0.912, p < 0.01, and a slope of 5.4 × 108 (area unit)/μg and an intercept of 2.5 × 107 (area unit). A Box-Cox power transformation indicated the optimum power was 0.1. The new standard curve of area0.1 versus injected MWF mass, with a slope of 19 (area unit)0.1/μg and an intercept of 3.6 (area unit)0.1, had r = 0.982, and p < 0.01. The standard curve using transformed data fit all the MWF data. The method blank glove rinses showed no MWF. Thus the worker’s hands were clean at the beginning of the test, and there was no contamination from handling by the investigators.

The chromatogram for each rinse of the MWF exposed gloves exhibited a set of peaks from 17 to 24 min with highest response at 20.1 min. The chromatograms for standards were similar. This confirmed utilization of the Rapid Tap MWF to generate standard curves with known concentrations in perfluorohexane to allow calculation of the MWF mass in each rinse (Fig. 1). The rinse masses did not decrease from the first rinse to the fifth rinse for the same glove as expected for a deposit on an inert, impermeable surface (except for Run 3 left glove for the first three rinses and Run 2 left glove for the first two rinses). The similar amounts of MWF in each rinse are probably extracted from the thin glove material interior. Therefore, the first rinse of the five was more representative of the MWF on the inner surface rather than summing the mass extracted in each set of five rinses. Assuming no losses to the worker’s hand, the first rinse corresponded to 1.3, 1.6, 1.4, 0.65, 0.58, and 0.62 μg/cm2 for the six gloves, respectively. The average amount was 1.0 ± 0.5 μg/cm2 for all gloves, 1.1 ± 0.4 μg/cm2 for left hand gloves, and 1.0 ± 0.6 μg/cm2 for right hand gloves. The difference between the left and right hand gloves was not significant at p ≤ 0.05. The above calculations used half the total outer surface area, since MWF exposed only the palm area. Since the solubility of the MWF in the glove material was at least ten times the highest concentration in these rinses, saturation conditions were not present. In the ASTM F739-99a method closed loop system, the normalized breakthrough time threshold is defined at 0.25 μg/cm2 (ASTM 2004). In the present study, all glove samples exceeded the ASTM threshold, indicative of a problem.

The mass of MWF in each 5-mL rinse for each tested glove

This project was funded by the UCLA Center for Occupational and Environmental Health (COEH), ASPH/NIOSH S1891-21/21, and NIOSH OH03754. Robert N. Phalen is thanked for valuable discussions. The UCLA Human Subjects Internal Review Board determined this study required no Human Subject Consent Form.

Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

ReferencesStandard test method for resistance of protective clothing materials to permeation by liquids or gases under conditions of continuous contact. ASTM method F739-99a, annual book of ASTM standards2004PAWest Conshohocken12991309ASTM (2004) Standard test method for resistance of protective clothing materials to permeation by liquids or gases under conditions of continuous contact. ASTM method F739-99a, annual book of ASTM standards, vol 11. West Conshohocken, PA, pp 1299–1309 ByersJPMetalworking Fluids1994New YorkMarcel DekkerByers JP (1994) Metalworking Fluids. Marcel Dekker, New York KlingnerTDBoenigerMFA critique of assumptions about selecting chemical-resistant gloves: a case for workplace evaluation of glove efficacyAppl Occup Environ Hyg20021736036710.1080/10473220252864969Klingner TD, Boeniger MF (2002) A critique of assumptions about selecting chemical-resistant gloves: a case for workplace evaluation of glove efficacy. Appl Occup Environ Hyg 17:360–367 12018400NIOSH (1998) Criteria for a recommended standard: occupational exposure to metalworking fluids. DHHS (NIOSH) Public No 98–102, Cincinnati, OhioPhalenRNQue HeeSSA moving robotic hand system for whole glove permeation and penetration: captan and nitrile glovesJ Occup Environ Hyg2008525727010.1080/15459620801934786Phalen RN, Que Hee SS (2008) A moving robotic hand system for whole glove permeation and penetration: captan and nitrile gloves. J Occup Environ Hyg 5:257–270 XuWQue HeeSSGas chromatography-mass spectrometry analysis of di-octyl disulfide in a straight oil metalworking fluid: application of differential permeation and Box-Cox transformationJ Chromatogr A20061101253110.1016/j.chroma.2005.09.076Xu W, Que Hee SS (2006a) Gas chromatography-mass spectrometry analysis of di-octyl disulfide in a straight oil metalworking fluid: application of differential permeation and Box-Cox transformation. J Chromatogr A 1101:25–31 16233901XuWQue HeeSSPermeation of a straight oil metalworking fluid through a disposable and a chemically protective nitrile gloveJ Hazard Mater2006B13770971510.1016/j.jhazmat.2006.03.052Xu W, Que Hee SS (2006b) Permeation of a straight oil metalworking fluid through a disposable and a chemically protective nitrile glove. J Hazard Mater B137:709–715 16650529XuWQue HeeSSPermeation of a straight oil metalworking fluid through disposable nitrile, chloroprene, vinyl, and latex glovesJ Hazard Mater2007B14792392910.1016/j.jhazmat.2007.01.114Xu W, Que Hee SS (2007) Permeation of a straight oil metalworking fluid through disposable nitrile, chloroprene, vinyl, and latex gloves. J Hazard Mater B147:923–929 17324502XuWQue HeeSSSwelling of four glove materials challenged by six metalworking fluidsArch Environ Contam Toxicol2008541810.1007/s00244-007-9011-7Xu W, Que Hee SS (2008a) Swelling of four glove materials challenged by six metalworking fluids. Arch Environ Contam Toxicol 54:1–8 17680173XuWQue HeeSSInfluence of collection solvent on permeation of di-n-octyl disulfide through nitrile glove materialJ Hazard Mater2008B15169269810.1016/j.jhazmat.2007.06.050Xu W, Que Hee SS (2008b) Influence of collection solvent on permeation of di-n-octyl disulfide through nitrile glove material. J Hazard Mater B151:692–698 17662521