Caloric intake among children could be reduced if sugar-sweetened beverages were replaced by plain water. School drinking water infrastructure is dictated in part by state plumbing codes, which generally require a minimum ratio of drinking fountains to students. Actual availability of drinking fountains in schools and how availability differs according to plumbing codes is unknown.
We abstracted state plumbing code data and used the 2010 YouthStyles survey data from 1,196 youth aged 9 through 18 years from 47 states. We assessed youth-reported school drinking fountain or dispenser availability and differences in availability according to state plumbing codes, sociodemographic characteristics, and area-level characteristics.
Overall, 57.3% of youth reported that drinking fountains or dispensers in their schools were widely available, 40.1% reported there were only a few, and 2.6% reported that there were no working fountains. Reported fountain availability differed significantly (
Interventions designed to increase consumption of water may want to consider the role of plumbing codes in availability of school drinking fountains.
Americans can limit excess caloric intake and weight gain by drinking water and other beverages with few or no calories (
Providing greater access to free drinking water in schools is a strategy to support healthy beverage intake among youth (
We used the 2010 YouthStyles survey, which was administered by Synovate, Inc, a market research firm. This national mail survey assessed health-related attitudes and behaviors among children. Participants were selected from children of respondents to the ConsumerStyles survey, a consumer mail survey drawn from a mail panel of 200,000 potential respondents. The sampling design is stratified by region, household income, population density, age, and household size and includes an oversample of low-income and minority participants and households with children to ensure adequate representation of these groups. In 2010, a total of 10,328 people completed the ConsumerStyles survey (response rate, 51.6%).
Following survey completion by ConsumerStyles participants, 2,401 YouthStyles surveys were sent to a stratified sample of adults with children aged 9 through 19 years living at home, with instructions that the sampled youth should complete the survey. Of the 2,401 YouthStyles surveys sent, 1,197 surveys were completed, yielding a youth response rate of 49.9%. Respondents were youth from 47 states and the District of Columbia. Alaska, Hawaii, and Wyoming were not represented in the study population. The YouthStyles survey is weighted to match the US Current Population Survey (
There were no statistical differences in YouthStyles responders and nonresponders by parental income, home ownership, household size, or sex of child. However, response rates differed by child age (χ2 test,
We excluded from analyses 57 participants because of a missing or invalid response to the question regarding school drinking fountains, resulting in a sample of 1,140 youth. Additional participants were excluded from analyses involving plumbing code variables because their state did not have a code or because the code did not specify a fountain to student ratio or a proportion of fountains that could be replaced by nonplumbed sources. As a result, 62 participants were excluded from analyses of fountain to student ratios and 43 participants were excluded from analyses of nonplumbed water sources, leaving sample sizes of 1,078 and 1,097, respectively. Excluded participants did not differ with regards to age, sex, region, or income but included a higher proportion of Hispanic and “other race” youth.
Participants were asked to rate their agreement with the following statements: “Does your school have working drinking fountains or dispensers that you can drink from?” Response choices available were “Yes, there are many,” “Yes, only are a few,” “There are no water fountains,” “No, none work,” and “I don’t know.” After excluding those youth who responded “I don’t know” (missing or invalid responses) as noted above, 2 categories were created for the water access variable: 1) drinking fountains widely available, and 2) few or no working drinking fountains.
We included in our analysis demographic variables of sex, race/ethnicity (NH white, NH black, Hispanic, or NH Other), age (9–10 y [elementary school], 11–13 y [middle school], and 14–18 y [high school]), and annual household income (<$25,000, $25,000–$59,999, and >$59,999). Cutpoints for annual household income approximately correspond to 100% and 250% income to poverty level ratios for a family of 4.
Respondents were classified by the respondent’s state of residence according to the following 4 US Census regions: Northeast, South, Midwest, and West (
Plumbing code data for each state were obtained through legal research of each state during 2012. First, we consulted online data available from the International Code Council (
With the exception of Arkansas, where the school fountain requirement was repealed 1 month before code abstraction, the codes referenced are the codes that were in effect as of August 2012. If school-specific plumbing provisions differentiated between “existing” and “new” buildings, the fountain requirement for “new” facilities was used. Several states recognize model codes (such as the International Plumbing Code [
For each state with available code data, we abstracted the minimum fixture standards for drinking fountains in elementary and secondary school buildings and determined whether schools were allowed to substitute nonplumbed water coolers for plumbed drinking fountains. The required number of fountains per student was classified as 1 fountain per fewer than 100 students, 1 fountain per 100 students, or 1 fountain per more than 100 students. On the basis of the average class size, Louisiana, where code specified “1 per each 3 classrooms with at least one per floor,” was classified as 1 fountain per fewer than 100 students. Plumbing codes for Montana and Oregon only specified 1 fountain per floor and did not specify a required number of fountains per student. On the basis of what was found in codes across states, the percentage of fountains that can be replaced with bottled water coolers was classified in analyses as none, 50%, or 100%.
All analysis was conducted using SAS 9.3 (SAS Institute, Inc, Cary, North Carolina). First, univariate frequencies of perceived school drinking fountain access were estimated. Next, bivariate analysis was performed to assess differences in prevalence of widely available school drinking water access according to age, sex, race/ethnicity, household income, region, metropolitan status, the fountain to student ratio specified in the plumbing code, and whether the plumbing code allowed nonplumbed water dispensers. Because all state plumbing codes that specify fountain to student ratios of 1 fountain per more than 100 students also do not allow substitution of plumbed drinking fountains, and because nearly all observations in the data set corresponding with fountain to student ratios of 1 fountain per more than 100 students occur in the West, it was not possible to include these 3 variables (ie, region, fountain to student ratio, and allowance of nonplumbed water dispensers) in the same model. Therefore, 3 multivariable logistic models were fit after controlling for age, sex, race/ethnicity, household income, and metropolitan status. This analysis was exempt from the Centers for Disease Control and Prevention (CDC) Institutional Review Board process because personal identifiers were not included in the data provided to CDC.
Overall, 57.3% of respondents reported that school drinking fountains or dispensers were widely available, 40.1% reported there were only a few, and 2.6% reported that there were no working fountains available in their schools. Statewide plumbing codes for school buildings are shown in
| State | Ratio of Fountains to Students | % of Fountains That Can Be Replaced With Nonplumbed Water Sources |
|---|---|---|
| Alabama | 1 per 100 | 50% |
| Alaska | 1 per first 150 and 1 per each 300 thereafter | None |
| Arizona | 1 per 50 (grades K–8); 1 per 100 (grades 9–12) | 100% |
| Arkansas | 1 per 30 | None |
| California | 1 per first 150 and 1 per each 300 thereafter | None |
| Colorado | 1 per 100 | 50% |
| Connecticut | 1 per 100 | 50% |
| Delaware | 1 per 100 | 50% |
| Florida | 1 per 100 | 50% |
| Georgia | 1 per 100 | 50% |
| Hawaii | 1 per 100 | 50% |
| Idaho | 1 per first 150 and 1 per each 300 thereafter | None |
| Illinois | 1 per 75 | 100% |
| Indiana | 1 per 75 | 100% |
| Iowa | 1 per 100 | 50% |
| Kansas | 1 per 100 | 50% |
| Kentucky | 1 per 75 | 100% |
| Louisiana | 1 per each 3 classrooms with at least 1 per floor | None |
| Maine | 1 per first 150 and 1 per each 300 thereafter | None |
| Maryland | 1 per 100 | 50% |
| Massachusetts | 1 per 75 | None |
| Michigan | 1 per 100 | 50% |
| Minnesota | 1 per 100 | 50% |
| Mississippi | No statewide code identified | No statewide code identified |
| Missouri | No statewide code identified | No statewide code identified |
| Montana | 1 per floor | Individual case-by-case basis |
| Nebraska | 1 per first 150 and 1 per each 300 thereafter | None |
| Nevada | 1 per 100 | 50% |
| New Hampshire | 1 per 40 | None |
| New Jersey | 1 per 100 | None |
| New Mexico | 1 per 100 | 50% |
| New York | 1 per 100 | 50% |
| North Carolina | 1 per 100 | None |
| North Dakota | 1 per 100 | 100% |
| Ohio | 1 per 100 | 50% |
| Oklahoma | 1 per 100 | 50% |
| Oregon | 1 per floor | None |
| Pennsylvania | 1 per 100 | 50% |
| Rhode Island | 1 per 100 | 50% |
| South Carolina | 1 per 100 | None |
| South Dakota | 1 per first 150 and 1 per each 300 thereafter | None |
| Tennessee | 1 per 100 | 50% |
| Texas | 1 per 100 | 50% |
| Utah | 1 per 100 | 50% |
| Vermont | 1 per 100 | 50% |
| Virginia | 1 per 100 | 50% |
| Washington | 1 per first 150 and 1 per each 500 thereafter | None |
| West Virginia | 1 per 100 | 50% |
| Wisconsin | 1 per 100 | 50% |
| Wyoming | 1 per 100 | None |
Plumbing code data for each state obtained through legal research during 2012 by using online data from the International Code Council (
Perceived school water access differed by race/ethnicity, region, fountain to student ratio specified in the plumbing code, and allowance of nonplumbed water dispensers (
| Characteristic (No. of Respondents) | Student-Reported Availability of School Water Fountains or Dispensers | χ2
| |
|---|---|---|---|
| Few or None | Widely Available | ||
|
| 487 (42.6%) | 653 (57.4%) | NA |
|
| |||
| 9–10 (n = 221) | 44.4% | 55.6% | .45 |
| 11–13 (n = 326) | 39.8% | 60.2% | |
| 14–18 (n = 593) | 43.4% | 56.6% | |
|
| |||
| Male (n = 643) | 40.9% | 59.1% | .27 |
| Female (n = 497) | 44.3% | 55.7% | |
|
| |||
| White (n = 775) | 43.0% | 57.0% | .009 |
| Black (n = 125) | 32.2% | 67.8% | |
| Hispanic (n = 159) | 49.6% | 50.4% | |
| Other (n = 81) | 44.9% | 55.1% | |
|
| |||
| <25,000 (n = 166) | 42.8% | 57.2% | .55 |
| 25,000–59,999 (n = 324) | 44.5% | 55.5% | |
| >59,999 (n = 650) | 41.2% | 58.8% | |
|
| |||
| Northeast (n = 227) | 48.5% | 51.5% | <.001 |
| South (n = 423) | 39.4% | 60.4% | |
| Midwest (n = 290) | 34.6% | 65.4% | |
| West (n = 200) | 54.3% | 45.7% | |
|
| |||
| Nonmetropolitan area (n = 233) | 43.8% | 56.2% | .30 |
| Population <500,000 (n = 204) | 37.9% | 62.1% | |
| Population ≥500,000 (n = 703) | 43.5% | 56.5% | |
|
| |||
| 1 fountain per <100 students (n = 182) | 42.5% | 57.6% | .0048 |
| 1 fountain per 100 students (n = 750) | 40.0% | 60.1% | |
| 1 fountain per >100 students (n = 146) | 54.6% | 45.4% | |
|
| |||
| Nonplumbed water sources may substitute for all fountains (n = 135) | 39.0% | 61.0% | .0007 |
| Nonplumbed water sources may substitute half of fountains (n = 647) | 39.0% | 61.1% | |
| Nonplumbed water sources may not substitute for fountains (n = 315) | 51.5% | 48.5% | |
Abbreviation: NA, not applicable.
Values are expressed as percentages unless otherwise indicated. Rows may not sum to 100 because of rounding
Participants responded either “Yes, there are many,” “Yes, only a few,” “No, none work,” or “There are no water fountains” to the question “Does your school have working drinking fountains or dispensers that you can drink from?” “Widely available drinking fountains” correspond with participants reporting “Yes, there are many.”
Excluded participants in states where there was no code.
Excluded participants in states where the state code did not specify a fountain to student ratio or a proportion of fountains that could be replaced by nonplumbed sources.
In multivariable analysis, black youth were more likely to report widely available fountains or dispensers compared with white youth (odds ratio [OR], 1.6; 95% confidence interval [CI], 1.1–2.3). Youth living in the Midwest (OR, 2.2; 95% CI 1.5–3.2) and South (OR, 1.6; 95% CI, 1.2–2.3) were significantly more likely to report widely available school drinking fountains than youth in the West. Youth living in states where plumbing codes required 1 fountain per more than 100 students were significantly less likely (OR, 0.6; 95% CI, 0.4–0.9) to report widely available drinking fountains than youth residing where plumbing codes specified 1 fountain per 100 students. Compared with youth residing where nonplumbed drinking fountains were not allowed, youth residing in states where 100% or 50% substitution of plumbed fountains with nonplumbed water dispensers was allowed were significantly more likely to report widely available drinking water fountains or dispensers (OR, 1.7; 95% CI, 1.1–2.6 for 100% substitution allowed; OR, 1.7; 95% CI, 1.3–2.2 for 50% substitution allowed) (
| Variable | Odds Ratio (95% Confidence Interval) |
|---|---|
|
| |
| 9–10 (n = 221) | 1 [Reference] |
| 11–13 (n = 326) | 1.2 (0.8–1.7) |
| 14–18 (n = 593) | 1.0 (0.8–1.4) |
|
| |
| Male (n = 643) | 1 [Reference] |
| Female (n = 497) | 0.9 (0.7–1.1) |
|
| |
| White (n = 775) | 1 [Reference] |
| Black (n = 125) | 1.6 (1.1–2.3) |
| Hispanic (n = 159) | 0. 9 (0.6–1.2) |
| Other (n = 81) | 1.0 (0.6–1.9) |
|
| |
| <25,000 (n = 166) | 1 [Reference] |
| 25,000–59,999 (n = 324) | 0.9 (0.7–1.4) |
| >59,999 (n = 650) | 1.1 (0.8–1.6) |
|
| |
| Northeast (n = 227) | 1.2 (0.8–1.8) |
| South (n = 423) | 1.6 (1.2–2.3) |
| Midwest (n = 290) | 2.2 (1.5–3.2) |
| West (n = 200) | 1 [Reference] |
|
| |
| Nonmetropolitian area (n = 233) | 0.9 (0.7–1.3) |
| Population <500,000 (n = 204) | 1.2 (0.9–1.7) |
| Population ≥500,000 (n = 703) | 1 [Reference] |
|
| |
| 1 fountain per <100 students (n = 182) | 0.9 (0.7–1.3) |
| 1 fountain per 100 students (n = 750) | 1 [Reference] |
| 1 fountain per >100 students (n = 146) | 0.6 (0.4–0.9) |
|
| |
| Nonplumbed water sources may substitute for all fountains (n = 135) | 1.7 (1.1–2.6) |
| Nonplumbed water sources may substitute half of fountains (n = 647) | 1.7 (1.3–2.2) |
| Nonplumbed water sources may not substitute for fountains (n = 315) | 1 [Reference] |
Participants responded either “Yes, there are many”, “Yes, only a few”, “No, none work”, or “There are no water fountains” to the question “Does your school have working drinking fountains or dispensers that you can drink from?” “Widely available drinking fountains” correspond with participants reporting “Yes, there are many.”
Odds ratios for age, sex, race/ethnicity, household income, census region, and metropolitan area size adjusted for one another; odds ratios for drinking fountains required per student and allowance of nonplumbed water sources adjusted for age, sex, race/ethnicity, household income, and metropolitan area size.
Excluded participants in states where there was no code.
Excluded participants in states where the state code did not specify a fountain to student ratio or a proportion of fountains that could be replaced by nonplumbed sources.
We found that more than 40% of youth reported that there are few working drinking fountains or dispensers available in their school, and 1 in 25 youth reported there are no working fountains or dispensers. We also found regional differences in youth-reported access, with reported access lowest in the West and highest in the Midwest. These differences may be partially due to state plumbing codes, which differ greatly by region. To our knowledge, this is the only study to examine school drinking water access at a national level or to examine the association of state plumbing codes with water access in schools.
Increasing free drinking water access in schools is gaining greater attention as a means of encouraging healthy beverage intake among children, with recent regulatory requirements implemented at both the state and federal level (
Our study suggests that water access may be greater where plumbing codes require at least 1 drinking fountain per 100 students and where codes allow the substitution of nonplumbed water dispensers for plumbed drinking fountains. However, the clustering of these 2 attributes in state plumbing codes because of widespread adoption of published model codes makes it difficult to separate the effects of fountain to student ratio and allowing nonplumbed water fountains to be substituted for plumbed water fountains. Specifically, all state plumbing codes that specify fountain to student ratios of 1 fountain per more than 100 students also do not allow any substitution for plumbed drinking fountains. Although 3 non-Western states specify fountain to student ratios of 1 fountain per more than 100 students (Maine, Nebraska, and South Dakota), the small samples from these states limited our ability to separate the effect of plumbing codes on school water availability from that of region.
Regional factors other than plumbing codes could explain regional differences. In general, the arid climate of many Western states can create challenges in ensuring adequate drinking water supplies for their populations and may thus encourage an atmosphere of water conservation that overrides access concerns (
This study has several limitations. First, we could not separate the effects of plumbing codes from those of region. Second, we used youth-reported drinking fountain access, from a survey offered only in English, rather than objective measurement. Future research is needed on how student-reported water access corresponds to actual access and to validate water access survey items. Third, we did not have information on local municipal plumbing codes or school wellness policies, which may go beyond state plumbing codes in specifying water access requirements in schools. Fourth, we did not have data on the age of the school facilities. Age of school facilities may be a factor in how plumbing codes associate with actual water access, because codes may change over time and broken fountains may come out of service and not be replaced. Furthermore, water access may change over time as the number of students attending a school changes and schools undergo additions or renovations that either add or remove fountains. Finally, because of selection bias associated with the use of a convenience sample from a mail panel survey and a low response rate, our findings may not be generalizable nationally. However, the study population included participants from 47 states and the District of Columbia who were sampled proportionately to state populations, and participants were weighted to match the US Current Population Survey (
We found that 4 in 10 youth report that there are only a few working drinking fountains or dispensers in their schools, and 1 in 25 indicated that they had no working fountains or dispensers in their school. Additionally, student-reported drinking fountain availability, after controlling for other factors, was significantly different by race/ethnicity, region, the fountain to student ratio specified in state plumbing codes, and whether the plumbing code allowed nonplumbed water sources. Further research regarding how drinking fountain requirements in plumbing codes relate to drinking water availability in schools and other places would be useful for states and communities that wish to increase drinking water access to support healthy beverage intake among their residents.
Additional support for this project was provided in part by cooperative agreements with CDC (no. U48DP001946, including the Nutrition and Obesity Policy Research and Evaluation Network).
The opinions expressed by authors contributing to this journal do not necessarily reflect the opinions of the U.S. Department of Health and Human Services, the Public Health Service, the Centers for Disease Control and Prevention, or the authors' affiliated institutions.