Investigation of purging and airlock contamination of mobile refuge alternatives
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

Investigation of purging and airlock contamination of mobile refuge alternatives

Filetype[PDF-3.36 MB]


  • English

  • Details:

    • Description:
      "The National Institute for Occupational Safety and Health (NIOSH) Office of Mine Safety and Health Research (OMSHR) has conducted research to evaluate the effectiveness of purging of mine refuge alternatives (RAs). Two questions were addressed experimentally: (1) Does the current generation of mobile refuge alternatives meet the requirements of 30 CFR4 § 7.508 (c) (2) which requires RAs to be capable of purging the internal atmosphere from 400 ppm of carbon monoxide (CO) to 25 ppm? (2) What is the relationship between the concentration of noxious gases in the mine atmosphere external to the refuge alternative and the concentration that will be present inside the refuge alternative following entry of miners but prior to purging? The goal of the second question was to evaluate the appropriateness of the 400-ppm criterion, given that ambient post-accident mine concentrations of CO can be in the thousands of ppm. A tent-type and a rigid steel mobile refuge alternative were used to investigate the first question. Carbon monoxide (CO) and sulfur hexafluoride (SF6) were used as contaminant gases as part of this study, and the individual experiments were conducted with the purging area of the RA occupied by zero, one, or seven simulated (when CO was used) or live (when SF6 was used) occupants. To investigate the second question, the aforementioned RAs were used along with a third airlock constructed for and employed in the experiments. The volume and size of the entry door into the constructed airlock were roughly in the middle of the range of values for the rigid and tent-type RAs. The RAs and constructed airlock were placed in a large sealed reverberation room, and SF6 gas was released into the reverberation room as a surrogate for CO. Experiments were conducted to determine the gas concentrations inside the airlock after groups of test subjects (representing miners) had entered.." --NIOSHTIC-2 http://www.cdc.gov/niosh/mining/Works/coversheet1873.html

      Suggested citation: NIOSH [2014]. Investigation of Purging and Airlock Contamination of Mobile Refuge Alternatives. By Bauer ER, Matty TJ, Thimons ED. Pittsburgh, PA: U.S. Department of Health and Human Services, Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health, DHHS (NIOSH) Publication 2014–116, RI 9694.

      NIOSHTIC2 Number: 2004385

      CDC-INFO Pub ID 221700

    • Content Notes:
      Eric R. Bauer, Timothy J. Matty, and Edward D. Thimons.