<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.3 20210610//EN" "JATS-archivearticle1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">1263115</journal-id><journal-id journal-id-type="pubmed-jr-id">22706</journal-id><journal-id journal-id-type="nlm-ta">J Aerosol Sci</journal-id><journal-id journal-id-type="iso-abbrev">J Aerosol Sci</journal-id><journal-title-group><journal-title>Journal of aerosol science</journal-title></journal-title-group><issn pub-type="ppub">0021-8502</issn></journal-meta><article-meta><article-id pub-id-type="pmid">39735567</article-id><article-id pub-id-type="pmc">11672863</article-id><article-id pub-id-type="doi">10.1016/j.jaerosci.2024.106442</article-id><article-id pub-id-type="manuscript">HHSPA2037907</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>A high-throughput, turbulent-mixing, condensation aerosol concentrator for direct aerosol collection as a liquid suspension</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Zervaki</surname><given-names>Orthodoxia</given-names></name><xref rid="A1" ref-type="aff">a</xref><xref rid="A2" ref-type="aff">b</xref></contrib><contrib contrib-type="author"><name><surname>Dionysiou</surname><given-names>Dionysios D.</given-names></name><xref rid="A2" ref-type="aff">b</xref><xref rid="FN1" ref-type="author-notes">1</xref></contrib><contrib contrib-type="author"><name><surname>Kulkarni</surname><given-names>Pramod</given-names></name><xref rid="A1" ref-type="aff">a</xref><xref rid="CR1" ref-type="corresp">*</xref></contrib></contrib-group><aff id="A1"><label>a</label>National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH, 45226, United States</aff><aff id="A2"><label>b</label>Environmental Engineering and Science Program, Department of Chemical and Environmental Engineering (ChEE), University of Cincinnati, Cincinnati, OH, 45221, United States</aff><author-notes><fn fn-type="con" id="FN1"><label>1</label><p id="P1">Deceased.</p></fn><corresp id="CR1"><label>*</label>Corresponding author.: <email>PSKulkarni@cdc.gov</email> (P. Kulkarni).</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>13</day><month>12</month><year>2024</year></pub-date><pub-date pub-type="ppub"><month>11</month><year>2024</year></pub-date><pub-date pub-type="pmc-release"><day>27</day><month>12</month><year>2024</year></pub-date><volume>182</volume><elocation-id>10.1016/j.jaerosci.2024.106442</elocation-id><abstract id="ABS1"><p id="P2">Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 &#x000d7; 16 &#x000d7; 18 cm, operates at an aerosol sample flowrate of up to 10 L min<sup>&#x02212;1</sup>, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles. We investigated the effect of operating parameters such as vapor temperature, growth tube wall temperature, and aerosol sample flowrate, along with the effect of particle diameter, inlet humidity, aerosol concentration, and operation time on TCALC performance. Nanoparticles with an initial aerodynamic diameter &#x02265;25 nm could grow to droplet diameters &#x0003e;1400 nm with an efficiency &#x02265;80%. Good droplet growth efficiency was achieved for sampled aerosol relative humidity &#x02265;9%. We measured complete aerosol collection for concentrations of &#x02264;3 &#x000d7; 10<sup>5</sup> cm<sup>&#x02212;3</sup>. The results showed good agreement between the particulate mass collected through the liquid collector and direct filter collection. The TCALC eliminates the need for sample preparation and filter digestion during chemical analysis, thereby increasing sample recovery and substantially improving the limit of detection and sensitivity of off-line trace analysis of collected liquid samples.</p></abstract><kwd-group><kwd>High flowrate</kwd><kwd>Aerosol collection</kwd><kwd>Liquid suspension</kwd><kwd>Condensational growth</kwd><kwd>Supersaturation</kwd><kwd>Rapid mixing</kwd></kwd-group></article-meta></front><body><sec id="S1"><label>1.</label><title>Introduction</title><p id="P3">Filter collection is the most common air sampling method when monitoring air quality in workplace atmospheres. For chemical analysis of the collected particulate filter sample, offline laboratory analytical methods are often used, which require time-consuming and labor-intensive sample preparation and pretreatment methods. Additionally, filters are susceptible to the adsorption and/or evaporation of moisture and/or volatile organic compounds contributing to increased measurement uncertainty (<xref rid="R2" ref-type="bibr">Barhate et al., 2022</xref>; <xref rid="R20" ref-type="bibr">Liu et al., 2014</xref>). Sample extraction from filters or other collection substrates or sample resuspension is often required for various analytical methods, such as for crystalline silica quantification using X-Ray Diffraction (XRD) in NIOSH Method 7500 (<xref rid="R23" ref-type="bibr">NIOSH, 2003a</xref>) or for the detection of metals using Inductively Coupled Plasma, Atomic Emission Spectroscopy (ICP-AES) in NIOSH Method 7300 (<xref rid="R24" ref-type="bibr">NIOSH, 2003b</xref>). However, these invasive sample preparation methods may result in sample damage or analyte loss (<xref rid="R6" ref-type="bibr">Daher et al., 2011</xref>; <xref rid="R8" ref-type="bibr">Gao et al., 2017</xref>), leading to poor detection limits or measurement uncertainty.</p><p id="P4">The condensation droplet growth technique has been widely employed for real-time aerosol measurement (<xref rid="R1" ref-type="bibr">Agarwal &#x00026; Sem, 1980</xref>; <xref rid="R3" ref-type="bibr">Bricard et al., 1976</xref>; <xref rid="R4" ref-type="bibr">Cheng, 2011</xref>; <xref rid="R9" ref-type="bibr">Hering et al., 2019</xref>; <xref rid="R10" ref-type="bibr">Hering et al., 2005</xref>; <xref rid="R30" ref-type="bibr">Ryan et al., 2015</xref>; <xref rid="R32" ref-type="bibr">Sinclair &#x00026; S.Hoopes, 1975</xref>). Condensation droplet growth apparatuses have also been effectively combined with inertial impaction for dry spot sample collection and offline chemical analysis (<xref rid="R7" ref-type="bibr">Eiguren Fernandez et al., 2014</xref>; <xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>; <xref rid="R40" ref-type="bibr">Zervaki et al., 2023</xref>). However, impaction inherently limits sampling flowrates because the heating of the collection substrate must be sufficient for rapid water evaporation to achieve dry sample collection. The droplet growth technique through condensation at high flowrates has been effectively integrated with direct collection in aqueous suspensions for bioaerosol collection (<xref rid="R13" ref-type="bibr">Jang et al., 2022</xref>; <xref rid="R22" ref-type="bibr">Nannu Shankar et al., 2024</xref>) and inorganic aerosol collection (<xref rid="R14" ref-type="bibr">Khlystov, 1995</xref>; <xref rid="R15" ref-type="bibr">Kidwell &#x00026; Ondov, 2001</xref>; <xref rid="R27" ref-type="bibr">Orsini et al., 2003</xref>; <xref rid="R33" ref-type="bibr">Sorooshian et al., 2006</xref>; <xref rid="R36" ref-type="bibr">Wang et al., 2013</xref>; <xref rid="R37" ref-type="bibr">Weber et al., 2001</xref>). However, these systems often involve cumbersome devices that are impractical for occupational or field applications requiring portability and automated operations.</p><p id="P5">Here we describe the development of a compact, high-throughput, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) designed for the direct collection of aerosols as a liquid suspension. The turbulent mixing condensational technique offers several advantages: it allows high sampling flowrates, reduces diffusional losses (<xref rid="R17" ref-type="bibr">Kim et al., 2002</xref>; <xref rid="R21" ref-type="bibr">Mavliev, 2002</xref>) enables fast droplet growth (<xref rid="R4" ref-type="bibr">Cheng, 2011</xref>; <xref rid="R35" ref-type="bibr">Wang et al., 2002</xref>) and results in more compact instrument geometries (<xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>). The TCALC system utilizes an aerosol sampling flowrate of up to 10 L min<sup>&#x02212;1</sup>. We investigated instrument performance as a function of operating parameters such as: (i) the temperature of the vapor, (ii) the temperature of the growth tube wall, (iii) aerosol diameter, (iv) inlet relative humidity, and (v) aerosol number concentration. We also compared the collection efficiency of the TCALC with that of the particulate filter collection.</p></sec><sec id="S2"><label>2.</label><title>Materials and methods</title><sec id="S3"><label>2.1.</label><title>Description of the TCALC</title><p id="P6">We have recently developed and evaluated a compact, high-flow, Turbulent-mixing Condensation Aerosol Concentrator (TCAC), designed for the direct collection of particles as a dried spot sample for analysis using various laser spectroscopy and microscopy methods (<xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>). The TCALC described in this work further builds on TCAC design to address specific needs with respect to high aerosol sample flow throughput and direct aerosol concentration into a liquid. The scheme involves rapid mixing of a cold, aerosol flow with a hot, water-vapor saturated flow, promoting condensational droplet growth to diameters that are easily collected via impaction. The TCAC scheme was modified to accommodate much higher aerosol sampling flowrates and enable direct aerosol collection as a liquid suspension. The modified device, referred to as the &#x0201c;TCALC&#x0201d;, is shown in <xref rid="F1" ref-type="fig">Fig. 1</xref>. It measures approximately 12 &#x000d7; 16 &#x000d7; 18 cm, and weighs less than 2 lb.</p><p id="P7">The hot water vapor flow is generated in the <italic toggle="yes">saturator</italic>, as described elsewhere (<xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>). A particle-free air flow with a flowrate in the range of 1&#x02013;2.5 L min<sup>&#x02212;1</sup> is introduced into a 30-cm-long, 2-mm-ID Nafion<sup>&#x02122;</sup> membrane tube (TT-110; Perma Pure LLC, Lakewood NJ), which is immersed in heated, distilled ultra-filtered water. The Nafion<sup>&#x02122;</sup> tube, a proton-exchange membrane, enables water vapor saturation of the particle-free airflow. A temperature controller (CN4116-R1-R2-LV; Omega, Norwalk CT) regulated the water temperature at 70, 75, 80 or 85 &#x000b0;C, using a cartridge heater (Yancheng Xinrong Electronics Industry, Ltd., China) and a resistance temperature detector (RTD-NPT-72-E; Omega Engineering Inc, Norwalk CT).</p><p id="P8">The hot, vapor-saturated flow exits the saturator through a 35-mm-long, clear polyvinyl chloride 0.0625&#x0201d; ID tubing and enters the <italic toggle="yes">mixing region</italic> through a 4-mm ID inlet, with a flow velocity ranging from 1.3 to 3.3 m s<sup>&#x02212;1</sup>. Simultaneously, the aerosol flow is introduced from the top of the mixing region, to eliminate potential wall losses, at an ambient temperature of 22 &#x000b0;C, through a 10-mm ID inlet, with a flowrate ranging from 8 to 10 L min<sup>&#x02212;1</sup>. The hot, vapor-saturated flow mixes rapidly at a 90-degree-angle with the cold aerosol flow, generating supersaturation and thereby promoting condensational growth of particle-encapsulated droplets(<xref rid="R31" ref-type="bibr">Sgro and Fern&#x01e9a;ndez de la Mora, 2004</xref>; <xref rid="R16" ref-type="bibr">Kim et al., 2003</xref>; <xref rid="R18" ref-type="bibr">Kousaka et al., 1982</xref>; <xref rid="R25" ref-type="bibr">Okuyama et al., 1984</xref>; <xref rid="R28" ref-type="bibr">Parsons and Mavliev, 2001</xref>; <xref rid="R35" ref-type="bibr">Wang et al., 2002</xref>).</p><p id="P9">The mixed flow is then introduced into the <italic toggle="yes">droplet growth region</italic>, which comprises of a 23-mm ID and 64-mm long aluminum cylinder with flat external surfaces. The growth tube is cooled using a set of thermoelectric coolers (CP14-127-045-L1-W4.5, Laird Thermal Systems, Morrisville NC). The two thermoelectric coolers along with a thermistor (TCS610; Wavelength Electronics, Bozeman MT) are connected to a temperature controller (MPT10000; Wavelength Electronics, Bozeman MT) to maintain desired temperature of the growth tube wall (in the range of 0&#x02013;15 &#x000b0;C). In the growth tube region, the mixing of the cold aerosol flow with the hot vapor-saturated flow continues, further extending supersaturation, nuclei activation, and droplet growth. This process is enhanced by cooling the growth tube walls (<xref rid="R28" ref-type="bibr">Parsons &#x00026; Mavliev, 2001</xref>; <xref rid="R37" ref-type="bibr">Weber et al., 2001</xref>). The internal cylindrical surface of the growth tube is covered with a rolled Durapore<sup>&#x000ae;</sup> PVDF membrane filter (GVWP00010; Sigma Aldrich Inc., St. Louis MO), where excess water vapor is condensed. The condensed water on the growth tube wall is then removed using a peristaltic pump. Separation of the aerosol sample from the condensed vapor from the walls enhances analytical detection limits (<xref rid="R34" ref-type="bibr">Wang et al., 2020</xref>; <xref rid="R38" ref-type="bibr">Wubulihairen et al., 2015</xref>).</p><p id="P10">Downstream of the droplet growth region, the grown droplets are directed into a narrow beam via a <italic toggle="yes">focusing nozzle</italic>. The jet diameter of the nozzle <inline-formula><mml:math id="M1" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> was calculated as follows (<xref rid="R12" ref-type="bibr">Hinds and Zhu, 2022</xref>):
<disp-formula id="FD1">
<label>(1)</label>
<mml:math id="M2" display="inline"><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mi>j</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mi>&#x003c1;</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:msup><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi>p</mml:mi><mml:mn>50</mml:mn></mml:mrow></mml:msub><mml:mn>2</mml:mn></mml:msup><mml:mi>U</mml:mi><mml:msub><mml:mi>C</mml:mi><mml:mi>c</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:mn>9</mml:mn><mml:mspace width="0.2em"/><mml:mi>&#x003bc;</mml:mi><mml:mspace width="0.2em"/><mml:mi>S</mml:mi><mml:mi>t</mml:mi><mml:msub><mml:mi>k</mml:mi><mml:mrow><mml:mn>50</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M3" display="inline"><mml:mrow><mml:msub><mml:mi>&#x003c1;</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the particle density, <inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mrow><mml:mi>p</mml:mi><mml:mn>50</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the particle diameter corresponding to 50% collection efficiency, <inline-formula><mml:math id="M5" display="inline"><mml:mi>U</mml:mi></mml:math></inline-formula> is the jet velocity, <inline-formula><mml:math id="M6" display="inline"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mi>c</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the Cunningham slip correction factor, <inline-formula><mml:math id="M7" display="inline"><mml:mrow><mml:mo>&#x003bc;</mml:mo></mml:mrow></mml:math></inline-formula> is the air dynamic viscosity, and <inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mi>t</mml:mi><mml:msub><mml:mi>k</mml:mi><mml:mrow><mml:mn>50</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is the Stokes number corresponding to 50% collection efficiency. For a round jet nozzle, <inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:mi>S</mml:mi><mml:mi>t</mml:mi><mml:msub><mml:mi>k</mml:mi><mml:mrow><mml:mn>50</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> is typically equal to 0.24. We determined that a nozzle diameter <inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>D</mml:mi><mml:mi>j</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> of 2.5 mm would effectively capture droplets with <inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mspace width="0.5em"/><mml:mo>&#x02265;</mml:mo><mml:mspace width="0.5em"/><mml:mn>1.7</mml:mn><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mspace width="0.5em"/><mml:mo>&#x02265;</mml:mo><mml:mspace width="0.5em"/><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:math></inline-formula>, at flowrates of 9 L min<sup>&#x02212;1</sup> or 12.5 L min<sup>&#x02212;1</sup>, respectively (<xref rid="R12" ref-type="bibr">Hinds and Zhu, 2022</xref>). These flowrates represent the minimum and maximum flowrates used, including both the aerosol and vapor streams.</p><p id="P11">After exiting the focusing nozzle, the grown droplets impinge on the internal wall surface of a second converging nozzle, which serves as the <italic toggle="yes">droplet impactor</italic>. The droplet impactor was designed to allow droplets to slide towards a 1.5-mm ID hole and accumulate in a small, easily replaceable polypropylene vial, forming a liquid suspension.</p></sec><sec id="S4"><label>2.2.</label><title>Experimental setup</title><sec id="S5"><label>2.2.1.</label><title>Droplet growth efficiency</title><p id="P12">We measured the droplet growth efficiency, which refers to the initiation of vapor condensation on the surface of the aerosol particles acting as nuclei and the growth, achieved through the TCALC as a function of the temperature of the vapor flow generated through the saturator <inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>, the temperature of the growth tube wall <inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>, the aerodynamic diameter of the seed particles <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and the relative humidity of the aerosol stream <inline-formula><mml:math id="M16" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>. The experimental set up used is shown in <xref rid="F2" ref-type="fig">Fig. 2</xref>.</p><p id="P13">Sodium chloride aerosol was generated through a jet nebulizer (Salter 8900 Series; Salter Labs, Arvin CA), and was subsequently dried using a diffusion dryer (model 3062, TSI Inc., Shoreview MN), containing silica gel desiccant. Near-monodisperse aerosol of desired aerodynamic diameter (<inline-formula><mml:math id="M17" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>25</mml:mn></mml:mrow></mml:math></inline-formula>, 50, 75, 100, 150, 200, 250 and 300 nm), was obtained using an Aerodynamic Aerosol Classifier (AAC; Cambustion Ltd, Cambridge, United Kingdom) operating at 1.5 L min<sup>&#x02212;1</sup>.</p><p id="P14">Upstream of the mixing region of the TCALC, two humidifiers (MH-110-12F-4; Perma Pure LLC, Lakewood NJ) were placed: one was placed downstream of the AAC and the second was placed in parallel with a valve, controlling the relative humidity of the dilution air and subsequently of the aerosol flow. The aerosol flow was introduced in the mixing region at a flowrate <inline-formula><mml:math id="M18" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> of 8, 9 or 10 L min<sup>&#x02212;1</sup>, an ambient temperature <inline-formula><mml:math id="M19" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> of 22 &#x000b0;C, and an <inline-formula><mml:math id="M20" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula> in the range of 9&#x02013;60%.</p><p id="P15">Water vapor was generated through the saturator at a fixed temperature of 70, 75, 80 and 85 &#x000b0;C. For these saturator temperatures, we have calculated the saturation ratio <inline-formula><mml:math id="M21" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>R</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and Kelvin diameter (seed particle diameter that neither grows nor evaporates; <inline-formula><mml:math id="M22" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>*</mml:mo></mml:mrow></mml:math></inline-formula>) as a function of the ratio of vapor-to-aerosol flowrate (see <xref rid="SD1" ref-type="supplementary-material">Section S1</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref>). <xref rid="SD1" ref-type="supplementary-material">Figure S-1</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref> shows that different saturator temperatures required different vapor-to-aerosol flowrate ratios <inline-formula><mml:math id="M23" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>v</mml:mi></mml:msub><mml:mo>/</mml:mo><mml:msub><mml:mi>Q</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>, to reach maximum <inline-formula><mml:math id="M24" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>R</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> or minimum <inline-formula><mml:math id="M25" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>*</mml:mo></mml:mrow></mml:math></inline-formula>. Therefore, when the aerosol flow temperature <inline-formula><mml:math id="M26" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> is 20 &#x000b0;C, a vapor-to-aerosol flowrate ratio of 0.25, 0.23, 0.18 and 0.13 should be used for a <inline-formula><mml:math id="M27" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> of 70, 75, 80, and 85 &#x000b0;C, to achieve <inline-formula><mml:math id="M28" display="inline"><mml:mrow><mml:msub><mml:mi>S</mml:mi><mml:mi>R</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> of approximately 1.9, 2.1, 2.3 and 2.5, respectively (<xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>). Particle-free air was introduced into the saturator, and a vapor-saturated flow was produced at a controlled flowrate <inline-formula><mml:math id="M29" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>v</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> of 1, 1.2, 1.3, 1.4, 1.6, 1.8, 2, 2.3 or 2.5 L min<sup>&#x02212;1</sup>.</p><p id="P16">Following the mixing of the cold aerosol flow with the hot vapor-saturated flow, the mixed flow was introduced into the droplet growth region, which was further &#x0201c;actively&#x0201d; cooled using thermoelectric coolers. The temperature of the growth tube was controlled at 0, 5, 10, and 15 &#x000b0;C. We also evaluated the collector when no cooling was applied on the droplet growth region.</p><p id="P17">A Condensation Particle Counter (model UWCPC 3786; TSI Inc., Shoreview MN) was used along with an Optical Particle Sizer (model OPS 3330; TSI Inc., Shoreview MN) downstream of the droplet growth region to assess the droplet growth efficiency. The CPC measured the number concentration of particles with a diameter of 2.5 nm&#x02013;3 &#x003bc;m, and the OPS measured the number concentration of particles within a diameter in the range of 300 nm to 10 &#x003bc;m. Measuring droplet size distribution and growth efficiency right at the exit of the condensational growth apparatus is impractical when using particle counters. To address this, the tubing used to transport the droplet stream from the droplet growth region to the particle counters was shielded with fiberglass woven tape to maintain the temperature of the droplet flow, preventing changes in droplet size distribution. Additionally, sharp bends and elbows were avoided to reduce wall losses and the tube length from the droplet growth region to the counters was identical to ensure similar inertial droplet losses for both particle counters. Measured growth efficiencies would serve as conservative estimates in case of appreciable droplet wall loss. Along with the CPC and the OPS, an external vacuum pump was used downstream of the TCALC to control the inlet aerosol flowrate at 8, 9 or 10 L min<sup>&#x02212;1</sup>.</p><p id="P18">Within the TCALC, the collection of enlarged droplets relies on inertial impaction. Thus, droplet growth to <inline-formula><mml:math id="M30" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:math></inline-formula> is imperative. It is worth noting that optical particle counters often underestimate the size of water droplets (<xref rid="R11" ref-type="bibr">Hinds &#x00026; Kraske, 1986</xref>), and their true aerodynamic diameter is expected to be larger than their measured optical diameter <inline-formula><mml:math id="M31" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>. In this study, the measured droplet growth efficiency refers to particle activation and droplet growth to <inline-formula><mml:math id="M32" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:math></inline-formula>. That corresponds to an estimated aerodynamic diameter &#x02265;1.8 &#x003bc;m ()(<xref rid="R5" ref-type="bibr">Chien et al., 2016</xref>; <xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>), sufficiently large for inertial collection. The droplet growth efficiency <inline-formula><mml:math id="M33" display="inline"><mml:mrow><mml:mfenced><mml:mi>&#x003b7;</mml:mi></mml:mfenced></mml:mrow></mml:math></inline-formula> was calculated as follows:
<disp-formula id="FD2">
<label>(2)</label>
<mml:math id="M34" display="inline"><mml:mrow><mml:mspace width="0.5em"/><mml:mi>&#x003b7;</mml:mi><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mi>O</mml:mi><mml:mi>P</mml:mi><mml:mi>S</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mi>C</mml:mi><mml:mi>P</mml:mi><mml:mi>C</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M35" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mi>O</mml:mi><mml:mi>P</mml:mi><mml:mi>S</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> denotes the number concentration with <inline-formula><mml:math id="M36" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:math></inline-formula>, as measured by the OPS, and <inline-formula><mml:math id="M37" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mrow><mml:mi>C</mml:mi><mml:mi>P</mml:mi><mml:mi>C</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> denotes the total number concentration as measured by the CPC.</p></sec><sec id="S6"><label>2.2.2.</label><title>Number concentration effect</title><p id="P19">The performance of the TCALC was also evaluated as a function of the particle number concentration of the inlet aerosol flow (<xref rid="SD1" ref-type="supplementary-material">Figure S-2</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref>). Crystalline silica test aerosol was generated using a fluidized bed aerosol generator (model 3400A, TSI Inc., Shoreview MN). The generator used a fine, ground silica powder (Min-U-Sil@5; US Silica, Katy TX) as the source material. The size distribution of the generated silica particles at the outlet of the fluidized bed is shown in <xref rid="SD1" ref-type="supplementary-material">Figure S-3</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref>. To control the number concentration of the aerosol, the generated aerosol flow was diluted with particle-free air downstream of the fluidized bed. The aerosol flowrate at the inlet of the collector was fixed at 10 L min<sup>&#x02212;1</sup>, and the relative humidity <inline-formula><mml:math id="M38" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and temperature of the aerosol stream <inline-formula><mml:math id="M39" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> were approximately 41.5% and 22.5 &#x000b0;C, respectively. The temperature of the generated vapor <inline-formula><mml:math id="M40" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and the growth tube wall <inline-formula><mml:math id="M41" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> was controlled at 85 &#x000b0;C and 0 &#x000b0;C, respectively.</p><p id="P20">A butanol-based Condensation Particle Counter (model CPC 3776, TSI Inc., Shoreview MN) was used downstream of the collector to quantify the fraction of the particles that were not captured by the TCALC. The CPC was also used upstream of the TCALC to measure the particle concentration at its inlet. The collection efficiency <inline-formula><mml:math id="M42" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:mi>C</mml:mi><mml:mo>.</mml:mo><mml:mi>E</mml:mi><mml:mo>.</mml:mo></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> achieved through the TCALC was calculated as follows:
<disp-formula id="FD3">
<label>(3)</label>
<mml:math id="M43" display="inline"><mml:mrow><mml:mi>C</mml:mi><mml:mo>.</mml:mo><mml:mi>E</mml:mi><mml:mo>.</mml:mo><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>&#x02212;</mml:mo><mml:msub><mml:mi>N</mml:mi><mml:mi>o</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M44" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the number concentration of the aerosols measured at the inlet of the collector, and <inline-formula><mml:math id="M45" display="inline"><mml:mrow><mml:msub><mml:mi>N</mml:mi><mml:mi>o</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> is the number concentration of the aerosols that were not collected in the TCALC.</p></sec><sec id="S7"><label>2.2.3.</label><title>Comparison with direct filter collection</title><p id="P21">The collection efficiency of the TCALC was compared to that of the filter-based collection method. We used the experimental setup shown in <xref rid="SD1" ref-type="supplementary-material">Figure S-4</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref>. Crystalline silica was generated using a fluidized bed aerosol generator. The size distribution of the generated aerosol at the outlet of the fluidized bed is shown in <xref rid="SD1" ref-type="supplementary-material">Figure S-3</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref>. The relative humidity <inline-formula><mml:math id="M46" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> of the aerosol stream ranged from 42.2% to 74.8%. The average temperature of the aerosol stream <inline-formula><mml:math id="M47" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> was approximately 21.5 &#x000b0;C.</p><p id="P22">The crystalline silica was collected simultaneously by the TCALC at a flowrate of 10 L min<sup>&#x02212;1</sup>, and a reference 0.4-&#x003bc;m pore size, 37-mm polycarbonate filter (225&#x02013;1609; SKC Inc., Eighty Four PA) at a flowrate of 10 L min<sup>&#x02212;1</sup>. The filter was placed in a closed-face filter cassette, collocated, and operated in parallel with the TCALC. A DustTrak<sup>&#x02122;</sup> DRX (model 8533, TSI Inc., Shoreview MN) was used in parallel with the TCALC and the filter cassette to monitor the mass concentration collected. When the collected particulate mass on the filter was estimated to have exceeded 100 &#x003bc;g, the reference filter was replaced during the collection process, to prevent sample &#x0201c;overloading&#x0201d; on the filter and a potential increase of the pressure drop (<xref rid="R29" ref-type="bibr">Raynor et al., 2011</xref>). The total mass collected on all the reference filters for each measurement was calculated by summing the individual filter gravimetric measurements.</p><p id="P23">Following the collection, both the droplet impactor and the collection vial of TCALC were removed to recover the collected crystalline silica particles. The droplet impactor was rinsed with 3 ml of isopropyl alcohol, allowing for the retrieval of trace particles adhering to the droplet impactor surface. The liquid rinse containing particles was combined with the collected suspension. The suspension was then vacuum-filtered through a 20 &#x003bc;m or 30 &#x003bc;m-pore-sized mesh nylon filter, with a diameter of 25 mm (NY2002500, NY3002500; Millipore Sigma, St. Louis MO) and a 0.4-&#x003bc;m pore size, 25-mm-diameter polycarbonate filter (225&#x02013;1608; SKC Inc., Eighty Four PA). The mesh nylon filter ensured removal of any impurities collected, including traces from the conductive silicone rubber tubing used for the sampling. The polycarbonate filter was used to recover the silica particles. The collection vial was rinsed with an additional 3 ml of isopropyl alcohol and the rinse was also subjected to filtration. The 25-mm-diameter polycarbonate filter was then placed in a temperature and relative humidity-controlled environment along with the 37-mm-diameter reference filter used during the aerosol collection, to dry. A microbalance (XPR6U Microbalance; Mettler Toledo, Columbus OH) was used for weighing the filters. The analyte mass collected on the filters <inline-formula><mml:math id="M48" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> was then calculated:
<disp-formula id="FD4">
<label>(4)</label>
<mml:math id="M49" display="inline"><mml:mrow><mml:msub><mml:mi>m</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mi>f</mml:mi></mml:msub><mml:mo>&#x02212;</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M50" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi>f</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M51" display="inline"><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula> denote the final and initial filter mass, respectively.</p></sec></sec></sec><sec id="S8"><label>3.</label><title>Results and discussion</title><sec id="S9"><label>3.1.</label><title>Saturator temperature effect</title><p id="P24"><xref rid="F3" ref-type="fig">Fig. 3</xref> shows the effect of the temperature of the saturator <inline-formula><mml:math id="M52" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> on the droplet growth efficiency of the TCALC. Higher sampling flowrates required higher saturator temperatures to achieve near&#x02013;complete activation. Particularly, when the aerosol flowrate was fixed at 8 L min<sup>&#x02212;1</sup>, droplet growth efficiency remained &#x02265;89% at <inline-formula><mml:math id="M53" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>&#x02265;</mml:mo><mml:mn>75</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>. When the aerosol flowrate was 9 L min<sup>&#x02212;1</sup>, droplet growth efficiency exceeded 92% at <inline-formula><mml:math id="M54" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>&#x02265;</mml:mo><mml:mn>80</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>. Similarly, at an aerosol flowrate of 10 L min<sup>&#x02212;1</sup>, droplet growth efficiency was &#x0003e;90% at <inline-formula><mml:math id="M55" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>.</p><p id="P25">The highest droplet growth efficiency was consistently observed for <inline-formula><mml:math id="M56" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula> across all tested aerosol flowrates. This was attributed to the greater temperature differential <inline-formula><mml:math id="M57" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:mi>&#x00394;</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> between the hot vapor and cold aerosol flow, which induces higher saturation ratios (<xref rid="R25" ref-type="bibr">Okuyama et al., 1984</xref>, <xref rid="R26" ref-type="bibr">1987</xref>). However, droplet growth could not be achieved at any of the tested flowrates when <inline-formula><mml:math id="M58" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>70</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>. Droplet growth efficiency to <inline-formula><mml:math id="M59" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>300</mml:mn><mml:mspace width="0.5em"/><mml:mtext>nm</mml:mtext></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M60" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>700</mml:mn><mml:mspace width="0.5em"/><mml:mtext>nm</mml:mtext></mml:mrow></mml:math></inline-formula>, and <inline-formula><mml:math id="M61" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1400</mml:mn><mml:mspace width="0.5em"/><mml:mtext>nm</mml:mtext></mml:mrow></mml:math></inline-formula> for the different aerosol flowrates at different <inline-formula><mml:math id="M62" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> was measured (<xref rid="SD1" ref-type="supplementary-material">Figure S-5</xref> in the <xref rid="SD1" ref-type="supplementary-material">SI</xref>). These data suggest that the lower efficiencies shown in <xref rid="F3" ref-type="fig">Fig. 3</xref> are more likely due to insufficient nuclei activation rather than insufficient growth of the droplets. This effect indicates a potential reduction in saturation ratio, perhaps due to a lower-than-expected temperature differential <inline-formula><mml:math id="M63" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:mi>&#x00394;</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> between the hot vapor-saturated and cold aerosol flow in the TCALC. Subsequently, a <inline-formula><mml:math id="M64" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> of 75, 80 and 85 &#x000b0;C can be used for an aerosol flowrate of 8, 9 and 10 L min<sup>&#x02212;1</sup>, respectively.</p><p id="P26">The greatest <inline-formula><mml:math id="M65" display="inline"><mml:mrow><mml:mi>&#x00394;</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:math></inline-formula> employed here corresponded to approximately 60 &#x000b0;C. Turbulent-mixing condensational droplet growth collectors usually employ higher <inline-formula><mml:math id="M66" display="inline"><mml:mrow><mml:mi>&#x00394;</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:math></inline-formula> (<xref rid="R25" ref-type="bibr">Okuyama et al., 1984</xref>; <xref rid="R28" ref-type="bibr">Parsons &#x00026; Mavliev, 2001</xref>; <xref rid="R37" ref-type="bibr">Weber et al., 2001</xref>) compared to the laminar-based condensational droplet growth collectors, where the <inline-formula><mml:math id="M67" display="inline"><mml:mrow><mml:mi>&#x00394;</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:math></inline-formula> is typically around 30&#x02013;35 &#x000b0;C (<xref rid="R7" ref-type="bibr">Eiguren Fernandez et al., 2014</xref>; <xref rid="R40" ref-type="bibr">Zervaki et al., 2023</xref>). However, the turbulent mixing condensational technique allows significantly higher flowrates in more compact instrument sizes (<xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>).</p></sec><sec id="S10"><label>3.2.</label><title>Particle diameter and operation time effect</title><p id="P27"><xref rid="F4" ref-type="fig">Fig. 4 (a)</xref> shows the effect of seed particle aerodynamic diameter on the performance of the TCALC. We measured consistent droplet growth efficiencies for all tested aerosol flowrates. Droplet growth efficiency was &#x02265;80% for <inline-formula><mml:math id="M68" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>&#x02264;</mml:mo><mml:mn>75</mml:mn><mml:mspace width="0.5em"/><mml:mtext>nm</mml:mtext></mml:mrow></mml:math></inline-formula>, and consistently surpassed 90% for seed particles with <inline-formula><mml:math id="M69" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>&#x02265;</mml:mo><mml:mn>100</mml:mn><mml:mspace width="0.5em"/><mml:mtext>nm</mml:mtext></mml:mrow></mml:math></inline-formula> across all tested flowrates. This shows that the TCALC can be effectively used for collection of particles in the diameter range tested <inline-formula><mml:math id="M70" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>&#x02265;</mml:mo><mml:mn>25</mml:mn><mml:mspace width="0.5em"/><mml:mtext>nm</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>.</p><p id="P28">We further examined the impact of the operation time of the TCALC on the droplet growth efficiency <inline-formula><mml:math id="M71" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> (<xref rid="F4" ref-type="fig">Fig. 4 (b)</xref>). The collector consistently exhibited reliable performance throughout an uninterrupted 60-min operation while activating sodium chloride aerosol with a seed aerodynamic diameter of 100 nm. At an aerosol flowrate of 8 L min<sup>&#x02212;1 <inline-formula><mml:math id="M72" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>75</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula></sup>, a droplet growth efficiency of &#x02265;78% was observed. At aerosol flowrates of 9 L min<sup>&#x02212;1</sup>
<inline-formula><mml:math id="M73" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>80</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and 10 L min<sup>&#x02212;1 <inline-formula><mml:math id="M74" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula></sup>, a more stable droplet growth efficiency was observed (&#x02265;86%) as a function of time. The reason for the somewhat unstable growth efficiency at 8 L min<sup>&#x02212;1</sup> is unclear and could likely be attributed to lower saturation ratio and an increasing uncertainty in measured growth efficiency at 8 L min<sup>&#x02212;1</sup>. It is worth noting that a higher <inline-formula><mml:math id="M75" display="inline"><mml:mrow><mml:mi>&#x00394;</mml:mi><mml:mi>T</mml:mi></mml:mrow></mml:math></inline-formula> is expected to yield near-complete activation of seed particles. Based on this data, we expect that the design of the mixing chamber in TCALC is adequate to prevent heat transfer between hot and cold flows (just before turbulent mixing) over few hours.</p></sec><sec id="S11"><label>3.3.</label><title>Growth tube temperature effect</title><p id="P29"><xref rid="F5" ref-type="fig">Fig. 5</xref> shows the effect of the growth tube temperature <inline-formula><mml:math id="M76" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> on the droplet growth efficiency of TCALC. We measured the highest efficiency (&#x02265;89%) at <inline-formula><mml:math id="M77" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>0</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula> across all tested aerosol flowrates. This indicates that acceptable operation performance of the TCALC necessitates cooling of the droplet growth region. However, the effect of the growth tube temperature was greater at lower aerosol flowrates (<inline-formula><mml:math id="M78" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>8</mml:mn><mml:mspace width="0.5em"/><mml:mtext>L</mml:mtext><mml:mspace width="0.5em"/><mml:msup><mml:mrow><mml:mtext>min</mml:mtext></mml:mrow><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula> or <inline-formula><mml:math id="M79" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>9</mml:mn><mml:mspace width="0.5em"/><mml:mtext>L</mml:mtext><mml:mspace width="0.5em"/><mml:msup><mml:mrow><mml:mtext>min</mml:mtext></mml:mrow><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>) compared to higher aerosol flowrates <inline-formula><mml:math id="M80" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>10</mml:mn><mml:mspace width="0.5em"/><mml:mtext>L</mml:mtext><mml:mspace width="0.5em"/><mml:msup><mml:mrow><mml:mtext>min</mml:mtext></mml:mrow><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>. The saturator temperature set for each aerosol flowrate varied&#x02013; <inline-formula><mml:math id="M81" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>75</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula> at 8 L min<sup>&#x02212;1</sup>, <inline-formula><mml:math id="M82" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>80</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula> at 9 L min<sup>&#x02212;1</sup>, and <inline-formula><mml:math id="M83" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula> at 10 L min<sup>&#x02212;1</sup>.</p><p id="P30">The efficiency of seed particle activation and droplet growth is directly related to the level of saturation achieved at the mixing point of the cold aerosol flow with the hot vapor-saturated flow. This saturation ratio is influenced by the temperature differential between the two flows and the ratio of vapor-to-aerosol flowrate, irrespective of their individual magnitudes. However, mixing of the two flows is not limited in the mixing region but can be also extended in the droplet growth region, leading to further particle activation and droplet growth. Therefore, high activation and droplet growth efficiency was anticipated when the highest saturator temperature was used <inline-formula><mml:math id="M84" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and/or at increased residence times within the droplet growth region. However, further experiments are necessary to investigate whether the saturation ratio at the mixing region or the residence time of the particles/droplets in the droplet growth region has a greater impact. These experiments would involve measuring droplet growth efficiency for different saturator temperatures set at a fixed aerosol flowrate, or varying aerosol flowrates at a fixed saturator temperature.</p></sec><sec id="S12"><label>3.4.</label><title>Relative humidity effect</title><p id="P31"><xref rid="F6" ref-type="fig">Fig. 6</xref> shows the droplet growth efficiency measured as a function of the relative humidity of the input aerosol flow. A <inline-formula><mml:math id="M85" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> of 85 &#x000b0;C was used at all aerosol flowrates. At an aerosol flowrate of 8 L min<sup>&#x02212;1</sup>, the droplet growth efficiency was &#x0003e;90% for <inline-formula><mml:math id="M86" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>&#x02265;</mml:mo><mml:mn>20</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula> and it remained &#x0003e;80% at an <inline-formula><mml:math id="M87" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula> of 9%. At a flowrate of 9 L min<sup>&#x02212;1</sup>, we measured a droplet growth efficiency of &#x02265;80% down to 30%<inline-formula><mml:math id="M88" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula>, dropping below 50% at an <inline-formula><mml:math id="M89" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula> of &#x02264;20%. At an aerosol flowrate of 10 L min<sup>&#x02212;1</sup>, the droplet growth efficiency measured was &#x0003e;85% at <inline-formula><mml:math id="M90" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula> values of &#x02265;40%, but decreased significantly at lower <inline-formula><mml:math id="M91" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula>.</p><p id="P32">Higher supersaturation ratios can be reached by increasing the water vapor content or relative humidity of the aerosol flow, thereby enhancing seed activation and droplet growth. Lower inlet aerosol flowrates resulted in higher droplet growth efficiencies even at low humidity levels of the input aerosol flow. This was attributed to the prolonged residence time of the mixed flow within the TCALC when lower aerosol flowrates were used.</p></sec><sec id="S13"><label>3.5.</label><title>Number concentration effect</title><p id="P33"><xref rid="F7" ref-type="fig">Fig. 7</xref> shows the measured collection efficiency of polydisperse silica particles relative to the particle number concentration. The collection efficiency remained consistently high (&#x0003e;95%) up to a particle number concentration of 3 &#x000d7; 10<sup>5</sup> cm<sup>&#x02212;3</sup>, beyond which it decreased to 56% at a particle number concentration of 10<sup>6</sup> cm<sup>&#x02212;3</sup>.</p><p id="P34">The observed drop in collection efficiency at higher particle number concentrations has been investigated before for various condensation droplet growth collectors, as discussed by <xref rid="R19" ref-type="bibr">Lewis and Hering (2013)</xref>. Water-based, laminar-flow condensation particle counters and collectors often suffer from heat release from water vapor condensation on particles, leading to elevated temperatures and subsequent reduction in the saturation ratio. Our previous study (<xref rid="R39" ref-type="bibr">Zervaki et al., 2024</xref>) showed the effect of increased number concentration on the activation and growth efficiency of 25-nm-diameter sodium chloride particles using &#x0201c;TCAC&#x0201d; for spot sample collection, which became prominent at a number concentration of &#x02265;3 &#x000d7; 10<sup>4</sup> cm<sup>&#x02212;3</sup>. In the current study, we evaluated the effect of number concentration on a polydisperse silica test aerosol. We did not probe the minimum nuclei diameter that can be collected at high number concentrations; however, our results suggest that collection is highly efficient when particulate mass is used as a performance metric.</p></sec><sec id="S14"><label>3.6.</label><title>Comparison with direct filter collection</title><p id="P35"><xref rid="F8" ref-type="fig">Fig. 8</xref> shows a comparison between crystalline silica mass collected through the TCALC and through direct filter collection. Good agreement is observed between the two aerosol collection techniques. A linear fit curve was plotted to the experimental data, with a slope of 0.98 and high linearity <inline-formula><mml:math id="M92" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msup><mml:mtext>R</mml:mtext><mml:mn>2</mml:mn></mml:msup><mml:mo>=</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula>.</p><p id="P36">Minor deviations observed in the collected particulate mass between the liquid collector and the filter can be attributed to the variation in activation and droplet growth efficiency within the TCALC, potential insignificant particle or droplet losses during condensational growth, and particulate sample loss during sample transfer and gravimetric measurement. Despite these variations, the strong agreement between the two collection techniques showed the successful use of the TCALC for direct aerosol collection in a liquid.</p><p id="P37">The TCALC was evaluated for an inlet aerosol flow temperature of approximately 22 &#x000b0;C; therefore, higher ambient temperatures would necessitate cooling the aerosol stream prior to mixing with the vapor. Moreover, we selected to evaluate TCALC using NaCl aerosol, which is commonly used for the calibration of water-based condensation devices (<xref rid="R4" ref-type="bibr">Cheng, 2011</xref>), and crystalline silica aerosol due to its relevance to our current research needs concerning workplace aerosol measurements. However, further investigation is needed to assess the impact of aerosol chemical composition and extended operation times (up to at least 8 h) on collection efficiency.</p><p id="P38">The TCALC can eliminate the need for sample redeposition on filters suitable for specific analytical measurements, such as the quantification of redeposited crystalline silica on silver filters using XRD (NIOSH Method 7500; <xref rid="R23" ref-type="bibr">NIOSH, 2003a</xref>). Additionally, it can be used as an alternative to direct filter collection when analyte needs to be in a liquid suspension, as in NIOSH Method 7300 for metal detection using ICP-AES (<xref rid="R24" ref-type="bibr">NIOSH, 2003b</xref>). Integrating particle collection using the TCALC with spectroscopy analysis methods such as ICP-AES, would be beneficial for evaluating the limits of detection (LODs) achievable with the liquid collector compared to other aerosol sampling and analytical techniques.</p></sec></sec><sec id="S15"><label>4.</label><title>Conclusions</title><p id="P39">The design and evaluation of a new, compact, high-throughput, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) for direct aerosol collection as liquid suspension was described. The TCALC unit measures approximately 12 &#x000d7; 16 &#x000d7; 18 cm. The collector can effectively operate at an aerosol sampling flowrate ranging from 8 to 10 L min<sup>&#x02212;1</sup>, using personal sampling pumps. Higher sampling flowrates required higher vapor temperatures to achieve near&#x02013;complete activation. Nanoparticles with an initial aerodynamic diameter &#x02265;25 nm were grown to droplets with an optical diameter &#x0003e;1400 nm, with an efficiency &#x02265;80%. Active cooling of the growth tube, where the droplet growth mainly occurs, significantly optimized the efficacy of the collector, particularly at higher sampling flowrates. The measured droplet growth efficiency was &#x0003e;80% for aerosol <inline-formula><mml:math id="M93" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi></mml:mrow></mml:math></inline-formula> values of &#x02265;9% at 8 L min<sup>&#x02212;1</sup>, &#x02265;80% for aerosol <inline-formula><mml:math id="M94" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>&#x02265;</mml:mo><mml:mn>30</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula> at 9 L min<sup>&#x02212;1</sup>, and &#x0003e;85% for aerosol <inline-formula><mml:math id="M95" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>&#x02265;</mml:mo><mml:mn>40</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula> at 10 L min<sup>&#x02212;1</sup>. We measured complete aerosol collection for number concentrations of &#x02264;3 &#x000d7; 10<sup>5</sup> cm<sup>&#x02212;3</sup>. Negligible particulate mass losses were observed when comparing the TCALC&#x02019;s collection performance with that of conventional filter collection. The TCALC eliminates the need for sample preparation and filter digestion during chemical analysis, offering the potential for substantially improved sensitivity of off-line trace analysis of collected liquid samples. The TCALC shows promise as a high-thoughput collector allowing access to several laboratory analytical and microscopy methods, without requiring time- and labor-intensive sample preparation methods.</p></sec><sec sec-type="supplementary-material" id="SM1"><title>Supplementary Material</title><supplementary-material id="SD1" position="float" content-type="local-data"><label>Supplementary Information</label><media xlink:href="NIHMS2037907-supplement-Supplementary_Information.docx" id="d67e2049" position="anchor"/></supplementary-material></sec></body><back><ack id="S17"><title>Acknowledgments</title><p id="P41">The authors would like to thank Derek Stinson for his contribution to building the prototype described in this work and for assisting with the experimental study.</p><sec id="S18"><title>Funding</title><p id="P42">This research was supported by a NIOSH intramural NORA grant (CAN 9390G1Y).</p></sec></ack><fn-group><fn fn-type="COI-statement" id="FN2"><p id="P43">Declaration of competing interest</p><p id="P44">The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.</p></fn><fn id="FN3"><p id="P45">Appendix A. Supplementary data</p><p id="P46">Supplementary data to this article can be found online at <ext-link xlink:href="10.1016/j.jaerosci.2024.106442" ext-link-type="doi">https://doi.org/10.1016/j.jaerosci.2024.106442</ext-link>.</p></fn><fn id="FN4"><p id="P47">CRediT authorship contribution statement</p><p id="P48"><bold>Orthodoxia Zervaki:</bold> Writing &#x02013; original draft, Methodology, Investigation, Formal analysis, Data curation, Conceptualization. <bold>Dionysios D. Dionysiou:</bold> Supervision. <bold>Pramod Kulkarni:</bold> Writing &#x02013; review &#x00026; editing, Supervision, Resources, Project administration, Funding acquisition, Conceptualization.</p></fn><fn id="FN5"><p id="P49">Disclaimer: The findings and conclusions in this report are those of the author(s) and do not necessarily represent the official position of the National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention.</p></fn><fn id="FN6"><p id="P50">Handling Editor: Chris Hogan</p></fn></fn-group><sec sec-type="data-availability" id="S16"><title>Data availability</title><p id="P40">Data will be made available on request.</p></sec><ref-list><title>References</title><ref id="R1"><mixed-citation publication-type="journal"><name><surname>Agarwal</surname><given-names>JK</given-names></name>, &#x00026; <name><surname>Sem</surname><given-names>GJ</given-names></name> (<year>1980</year>). <article-title>Continuous flow, single-particle-counting condensation nucleus counter</article-title>. <source>Journal of Aerosol Science</source>, <volume>11</volume>(<issue>4</issue>), <fpage>343</fpage>&#x02013;<lpage>357</lpage>. <pub-id pub-id-type="doi">10.1016/0021-8502(80)90042-7</pub-id></mixed-citation></ref><ref id="R2"><mixed-citation publication-type="journal"><name><surname>Barhate</surname><given-names>PG</given-names></name>, <name><surname>Le</surname><given-names>TC</given-names></name>, <name><surname>Shukla</surname><given-names>KK</given-names></name>, <name><surname>Lin</surname><given-names>ZY</given-names></name>, <name><surname>Hsieh</surname><given-names>TH</given-names></name>, <name><surname>Nguyen</surname><given-names>TTN</given-names></name>, <name><surname>Li</surname><given-names>Z</given-names></name>, <name><surname>Pui</surname><given-names>DYH</given-names></name>, &#x00026; <name><surname>Tsai</surname><given-names>CJ</given-names></name> (<year>2022</year>). <article-title>Effect of aerosol sampling conditions on PM2.5 sampling accuracy</article-title>. <source>Journal of Aerosol Science</source>, <volume>162</volume>. <pub-id pub-id-type="doi">10.1016/j.jaerosci.2022.105968</pub-id></mixed-citation></ref><ref id="R3"><mixed-citation publication-type="book"><name><surname>Bricard</surname><given-names>J</given-names></name>, <name><surname>Delattre</surname><given-names>P</given-names></name>, <name><surname>Madelaine</surname><given-names>G</given-names></name>, &#x00026; <name><surname>Pourprix</surname><given-names>M</given-names></name> (<year>1976</year>). <part-title>Detection of ultra-fine particles by means of a continuous flux condensation nuclei counter</part-title>. In <name><surname>Liu</surname><given-names>BYH</given-names></name> (Ed.), <source>Fine particles</source> (pp. <fpage>565</fpage>&#x02013;<lpage>580</lpage>). <publisher-loc>New York</publisher-loc>: <publisher-name>Academic Press</publisher-name>.</mixed-citation></ref><ref id="R4"><mixed-citation publication-type="book"><name><surname>Cheng</surname><given-names>Y</given-names></name> (<year>2011</year>). <part-title>Condensation particle counters</part-title>. In <name><surname>Kulkarni</surname><given-names>P</given-names></name>, <name><surname>Baron</surname><given-names>PA</given-names></name>, &#x00026; <name><surname>Willeke</surname><given-names>K</given-names></name> (Eds.), <source>Aerosol measurement: Principles, techniques, and ApplicationsAerosol measurement: Principles, techniques, and applications</source> (pp. <fpage>381</fpage>&#x02013;<lpage>392</lpage>). <publisher-name>Wiley</publisher-name>. <pub-id pub-id-type="doi">10.1002/9781118001684.ch17</pub-id>.</mixed-citation></ref><ref id="R5"><mixed-citation publication-type="journal"><name><surname>Chien</surname><given-names>CH</given-names></name>, <name><surname>Theodore</surname><given-names>A</given-names></name>, <name><surname>Wu</surname><given-names>CY</given-names></name>, <name><surname>Hsu</surname><given-names>YM</given-names></name>, &#x00026; <name><surname>Birky</surname><given-names>B</given-names></name> (<year>2016</year>). <article-title>Upon correlating diameters measured by optical particle counters and aerodynamic particle sizers</article-title>. <source>Journal of Aerosol Science</source>, <volume>101</volume>, <fpage>77</fpage>&#x02013;<lpage>85</lpage>. <pub-id pub-id-type="doi">10.1016/j.jaerosci.2016.05.011</pub-id></mixed-citation></ref><ref id="R6"><mixed-citation publication-type="journal"><name><surname>Daher</surname><given-names>N</given-names></name>, <name><surname>Ning</surname><given-names>Z</given-names></name>, <name><surname>Cho</surname><given-names>AK</given-names></name>, <name><surname>Shafer</surname><given-names>M</given-names></name>, <name><surname>Schauer</surname><given-names>JJ</given-names></name>, &#x00026; <name><surname>Sioutas</surname><given-names>C</given-names></name> (<year>2011</year>). <article-title>Comparison of the chemical and oxidative characteristics of particulate matter (PM) collected by different methods: Filters, impactors, and BioSamplers</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>45</volume>(<issue>11</issue>), <fpage>1294</fpage>&#x02013;<lpage>1304</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2011.590554</pub-id></mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>Eiguren Fernandez</surname><given-names>A</given-names></name>, <name><surname>Lewis</surname><given-names>GS</given-names></name>, &#x00026; <name><surname>Hering</surname><given-names>SV</given-names></name> (<year>2014</year>). <article-title>Design and laboratory evaluation of a sequential spot sampler for time-resolved measurement of airborne particle composition</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>48</volume>(<issue>6</issue>), <fpage>655</fpage>&#x02013;<lpage>663</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2014.911409</pub-id><pub-id pub-id-type="pmid">25045199</pub-id>
</mixed-citation></ref><ref id="R8"><mixed-citation publication-type="journal"><name><surname>Gao</surname><given-names>D</given-names></name>, <name><surname>Fang</surname><given-names>T</given-names></name>, <name><surname>Verma</surname><given-names>V</given-names></name>, <name><surname>Zeng</surname><given-names>L</given-names></name>, &#x00026; <name><surname>Weber</surname><given-names>RJ</given-names></name> (<year>2017</year>). <article-title>A method for measuring total aerosol oxidative potential (OP) with the dithiothreitol (DTT) assay and comparisons between an urban and roadside site of water-soluble and total OP</article-title>. <source>Atmospheric Measurement Techniques</source>, <volume>10</volume>(<issue>8</issue>), <fpage>2821</fpage>&#x02013;<lpage>2835</lpage>. <pub-id pub-id-type="doi">10.5194/amt-10-2821-2017</pub-id></mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Hering</surname><given-names>SV</given-names></name>, <name><surname>Lewis</surname><given-names>GS</given-names></name>, <name><surname>Spielman</surname><given-names>SR</given-names></name>, &#x00026; <name><surname>Eiguren-Fernandez</surname><given-names>A</given-names></name> (<year>2019</year>). <article-title>A MAGIC concept for self-sustained, water-based, ultrafine particle counting</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>53</volume>(<issue>1</issue>), <fpage>63</fpage>&#x02013;<lpage>72</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2018.1538549</pub-id></mixed-citation></ref><ref id="R10"><mixed-citation publication-type="journal"><name><surname>Hering</surname><given-names>SV</given-names></name>, <name><surname>Stolzenburg</surname><given-names>MR</given-names></name>, <name><surname>Quant</surname><given-names>FR</given-names></name>, <name><surname>Oberreit</surname><given-names>DR</given-names></name>, &#x00026; <name><surname>Keady</surname><given-names>PB</given-names></name> (<year>2005</year>). <article-title>A laminar-flow, water-based condensation particle counter (WCPC)</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>39</volume>(<issue>7</issue>), <fpage>659</fpage>&#x02013;<lpage>672</lpage>. <pub-id pub-id-type="doi">10.1080/02786820500182123</pub-id></mixed-citation></ref><ref id="R11"><mixed-citation publication-type="journal"><name><surname>Hinds</surname><given-names>WC</given-names></name>, &#x00026; <name><surname>Kraske</surname><given-names>G</given-names></name> (<year>1986</year>). <article-title>Performance of PMS model LAS-X optical particle counter</article-title>. <source>Journal of Aerosol Science</source>, <volume>17</volume>(<issue>1</issue>), <fpage>67</fpage>&#x02013;<lpage>72</lpage>. <pub-id pub-id-type="doi">10.1016/0021-8502(86)90007-8</pub-id></mixed-citation></ref><ref id="R12"><mixed-citation publication-type="book"><name><surname>Hinds</surname><given-names>WC</given-names></name>, &#x00026; <name><surname>Zhu</surname><given-names>Y</given-names></name> (<year>2022</year>). <source>Aerosol technology: Properties, behavior, and measurement of airborne particles</source> (<edition>3rd ed.</edition>). <publisher-name>Wiley</publisher-name>.</mixed-citation></ref><ref id="R13"><mixed-citation publication-type="journal"><name><surname>Jang</surname><given-names>J</given-names></name>, <name><surname>Bhardwaj</surname><given-names>J</given-names></name>, &#x00026; <name><surname>Jang</surname><given-names>J</given-names></name> (<year>2022</year>). <article-title>Efficient measurement of airborne viable viruses using the growth-based virus aerosol concentrator with high flow velocities</article-title>. <source>Journal of Hazardous Materials</source>, <volume>434</volume>, Article <fpage>128873</fpage>. <pub-id pub-id-type="doi">10.1016/j.jhazmat.2022.128873</pub-id><pub-id pub-id-type="pmid">35427967</pub-id>
</mixed-citation></ref><ref id="R14"><mixed-citation publication-type="journal"><name><surname>Khlystov</surname><given-names>A</given-names></name> (<year>1995</year>). <article-title>The steam-jet aerosol collector</article-title>. <source>Atmospheric Environment</source>, <volume>29</volume>(<issue>17</issue>), <fpage>2229</fpage>&#x02013;<lpage>2234</lpage>. <pub-id pub-id-type="doi">10.1016/1352-2310(95)00180-7</pub-id></mixed-citation></ref><ref id="R15"><mixed-citation publication-type="journal"><name><surname>Kidwell</surname><given-names>CB</given-names></name>, &#x00026; <name><surname>Ondov</surname><given-names>JM</given-names></name> (<year>2001</year>). <article-title>Development and evaluation of a prototype system for collecting sub-hourly ambient aerosol for chemical analysis</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>35</volume>(<issue>1</issue>), <fpage>596</fpage>&#x02013;<lpage>601</lpage>. <pub-id pub-id-type="doi">10.1080/02786820118049</pub-id></mixed-citation></ref><ref id="R16"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>CS</given-names></name>, <name><surname>Okuyama</surname><given-names>K</given-names></name>, &#x00026; <name><surname>de la Mora</surname><given-names>JF</given-names></name> (<year>2003</year>). <article-title>Performance evaluation of an improved particle size magnifier (PSM) for single nanoparticle detection</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>37</volume>(<issue>10</issue>), <fpage>791</fpage>&#x02013;<lpage>803</lpage>. <pub-id pub-id-type="doi">10.1080/02786820300913</pub-id></mixed-citation></ref><ref id="R17"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>CS</given-names></name>, <name><surname>Okuyama</surname><given-names>K</given-names></name>, &#x00026; <name><surname>Shimada</surname><given-names>M</given-names></name> (<year>2002</year>). <article-title>Performance of a mixing-type CNC for nanoparticles at low-pressure conditions</article-title>. <source>Journal of Aerosol Science</source>, <volume>33</volume>(<issue>10</issue>), <fpage>1389</fpage>&#x02013;<lpage>1404</lpage>. <pub-id pub-id-type="doi">10.1016/S0021-8502(02)00092-7</pub-id></mixed-citation></ref><ref id="R18"><mixed-citation publication-type="journal"><name><surname>Kousaka</surname><given-names>Y</given-names></name>, <name><surname>Niida</surname><given-names>T</given-names></name>, <name><surname>Okuyama</surname><given-names>K</given-names></name>, &#x00026; <name><surname>Tanaka</surname><given-names>H</given-names></name> (<year>1982</year>). <article-title>Development of a mixing type condensation nucleus counter</article-title>. <source>Journal of Aerosol Science</source>, <volume>13</volume>(<issue>3</issue>), <fpage>231</fpage>&#x02013;<lpage>240</lpage>. <pub-id pub-id-type="doi">10.1016/0021-8502(82)90064-7</pub-id></mixed-citation></ref><ref id="R19"><mixed-citation publication-type="journal"><name><surname>Lewis</surname><given-names>GS</given-names></name>, &#x00026; <name><surname>Hering</surname><given-names>SV</given-names></name> (<year>2013</year>). <article-title>Minimizing concentration effects in water-based, laminar-flow condensation particle counters</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>47</volume> (<issue>6</issue>), <fpage>645</fpage>&#x02013;<lpage>654</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2013.779629</pub-id><pub-id pub-id-type="pmid">24436507</pub-id>
</mixed-citation></ref><ref id="R20"><mixed-citation publication-type="journal"><name><surname>Liu</surname><given-names>CN</given-names></name>, <name><surname>Lin</surname><given-names>SF</given-names></name>, <name><surname>Awasthi</surname><given-names>A</given-names></name>, <name><surname>Tsai</surname><given-names>CJ</given-names></name>, <name><surname>Wu</surname><given-names>YC</given-names></name>, &#x00026; <name><surname>Chen</surname><given-names>CF</given-names></name> (<year>2014</year>). <article-title>Sampling and conditioning artifacts of PM2.5 in filter-based samplers</article-title>. <source>Atmospheric Environment</source>, <volume>85</volume>, <fpage>48</fpage>&#x02013;<lpage>53</lpage>. <pub-id pub-id-type="doi">10.1016/j.atmosenv.2013.11.075</pub-id></mixed-citation></ref><ref id="R21"><mixed-citation publication-type="journal"><name><surname>Mavliev</surname><given-names>R</given-names></name> (<year>2002</year>). <article-title>Turbulent mixing condensation nucleus counter</article-title>. <source>Atmospheric Research</source>, <volume>62</volume>(<issue>3&#x02013;4</issue>), <fpage>303</fpage>&#x02013;<lpage>314</lpage>. <pub-id pub-id-type="doi">10.1016/S0169-8095(02)00016-9</pub-id></mixed-citation></ref><ref id="R22"><mixed-citation publication-type="journal"><name><surname>Nannu Shankar</surname><given-names>S</given-names></name>, <name><surname>Vass</surname><given-names>WB</given-names></name>, <name><surname>Lednicky</surname><given-names>JA</given-names></name>, <name><surname>Logan</surname><given-names>T</given-names></name>, <name><surname>Messcher</surname><given-names>RL</given-names></name>, <name><surname>Eiguren-Fernandez</surname><given-names>A</given-names></name>, <name><surname>Amanatidis</surname><given-names>S</given-names></name>, <name><surname>Sabo-Attwood</surname><given-names>T</given-names></name>, &#x00026; <name><surname>Wu</surname><given-names>C-Y</given-names></name> (<year>2024</year>). <article-title>The BioCascade-VIVAS system for collection and delivery of virus-laden size-fractionated airborne particles</article-title>. <source>Journal of Aerosol Science</source>, <volume>175</volume>, Article <fpage>106263</fpage>. <pub-id pub-id-type="doi">10.1016/j.jaerosci.2023.106263</pub-id><pub-id pub-id-type="pmid">38680161</pub-id>
</mixed-citation></ref><ref id="R23"><mixed-citation publication-type="book"><collab>NIOSH</collab>. (<year>2003a</year>). <part-title>SILICA, CRYSTALLINE, by XRD (filter redeposition): Method 7500</part-title>. <source>In NIOSH manual of analytical methods (NMAM)</source>. <edition>Edition: Fourth</edition>. <comment><ext-link xlink:href="https://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf" ext-link-type="uri">https://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf</ext-link>.</comment></mixed-citation></ref><ref id="R24"><mixed-citation publication-type="book"><collab>NIOSH</collab>. (<year>2003b</year>). <part-title>ELEMENTS by ICP (Nitric/Perchloric acid ashing): Method 7300</part-title>. <source>In NIOSH manual of analytical methods (NMAM)</source>. <edition>Edition: Fourth</edition>. <comment><ext-link xlink:href="https://www.cdc.gov/niosh/docs/2003-154/pdfs/7300.pdf" ext-link-type="uri">https://www.cdc.gov/niosh/docs/2003-154/pdfs/7300.pdf</ext-link>.</comment></mixed-citation></ref><ref id="R25"><mixed-citation publication-type="journal"><name><surname>Okuyama</surname><given-names>K</given-names></name>, <name><surname>Kousaka</surname><given-names>Y</given-names></name>, &#x00026; <name><surname>Motouchi</surname><given-names>T</given-names></name> (<year>1984</year>). <article-title>Condensational growth of ultrafine aerosol particles in a new particle size magnifier</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>3</volume> (<issue>4</issue>), <fpage>353</fpage>&#x02013;<lpage>366</lpage>. <pub-id pub-id-type="doi">10.1080/02786828408959024</pub-id></mixed-citation></ref><ref id="R26"><mixed-citation publication-type="journal"><name><surname>Okuyama</surname><given-names>K</given-names></name>, <name><surname>Kousaka</surname><given-names>Y</given-names></name>, <name><surname>Warren</surname><given-names>DR</given-names></name>, <name><surname>Flagan</surname><given-names>RC</given-names></name>, &#x00026; <name><surname>Seinfeld</surname><given-names>JH</given-names></name> (<year>1987</year>). <article-title>Homogeneous nucleation by continuous mixing of high temperature vapor with Room temperature gas</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>6</volume>(<issue>1</issue>), <fpage>15</fpage>&#x02013;<lpage>27</lpage>. <pub-id pub-id-type="doi">10.1080/02786828708959116</pub-id></mixed-citation></ref><ref id="R27"><mixed-citation publication-type="journal"><name><surname>Orsini</surname><given-names>DA</given-names></name>, <name><surname>Ma</surname><given-names>Y</given-names></name>, <name><surname>Sullivan</surname><given-names>A</given-names></name>, <name><surname>Sierau</surname><given-names>B</given-names></name>, <name><surname>Baumann</surname><given-names>K</given-names></name>, &#x00026; <name><surname>Weber</surname><given-names>RJ</given-names></name> (<year>2003</year>). <article-title>Refinements to the particle-into-liquid sampler (PILS) for ground and airborne measurements of water soluble aerosol composition</article-title>. <source>Atmospheric Environment</source>, <volume>37</volume>(<issue>9&#x02013;10</issue>), <fpage>1243</fpage>&#x02013;<lpage>1259</lpage>. <pub-id pub-id-type="doi">10.1016/S1352-2310(02)01015-4</pub-id></mixed-citation></ref><ref id="R28"><mixed-citation publication-type="journal"><name><surname>Parsons</surname><given-names>C</given-names></name>, &#x00026; <name><surname>Mavliev</surname><given-names>R</given-names></name> (<year>2001</year>). <article-title>Design and characterization of a new, water-based, high sample-flow condensation nucleus counter</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>34</volume>(<issue>4</issue>), <fpage>309</fpage>&#x02013;<lpage>320</lpage>. <pub-id pub-id-type="doi">10.1080/02786820117366</pub-id></mixed-citation></ref><ref id="R29"><mixed-citation publication-type="book"><name><surname>Raynor</surname><given-names>PC</given-names></name>, <name><surname>Leith</surname><given-names>D</given-names></name>, <name><surname>Lee</surname><given-names>KW</given-names></name>, &#x00026; <name><surname>Mukund</surname><given-names>R</given-names></name> (<year>2011</year>). <part-title>Sampling and analysis using filters</part-title>. In <name><surname>Kulkarni</surname><given-names>P</given-names></name>, <name><surname>Baron</surname><given-names>PA</given-names></name>, &#x00026; <name><surname>Willeke</surname><given-names>K</given-names></name> (Eds.), <source>Aerosol measurement</source> (pp. <fpage>107</fpage>&#x02013;<lpage>128</lpage>). <publisher-name>Wiley</publisher-name>. <pub-id pub-id-type="doi">10.1002/9781118001684.ch7</pub-id>.</mixed-citation></ref><ref id="R30"><mixed-citation publication-type="journal"><name><surname>Ryan</surname><given-names>PH</given-names></name>, <name><surname>Son</surname><given-names>SY</given-names></name>, <name><surname>Wolfe</surname><given-names>C</given-names></name>, <name><surname>Lockey</surname><given-names>J</given-names></name>, <name><surname>Brokamp</surname><given-names>C</given-names></name>, &#x00026; <name><surname>LeMasters</surname><given-names>G</given-names></name> (<year>2015</year>). <article-title>A field application of a personal sensor for ultrafine particle exposure in children</article-title>. <source>The Science of the Total Environment</source>, <volume>508</volume>, <fpage>366</fpage>&#x02013;<lpage>373</lpage>. <pub-id pub-id-type="doi">10.1016/j.scitotenv.2014.11.061</pub-id><pub-id pub-id-type="pmid">25497676</pub-id>
</mixed-citation></ref><ref id="R31"><mixed-citation publication-type="journal"><name><surname>Sgro</surname><given-names>L</given-names></name>, &#x00026; <name><surname>Fern&#x01e9a;ndez de la Mora</surname><given-names>J</given-names></name> (<year>2004</year>). <article-title>A simple turbulent mixing CNC for charged particle detection down to 1.2 nm</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>38</volume>(<issue>1</issue>), <fpage>1</fpage>&#x02013;<lpage>11</lpage>. <pub-id pub-id-type="doi">10.1080/02786820490247560</pub-id></mixed-citation></ref><ref id="R32"><mixed-citation publication-type="journal"><name><surname>Sinclair</surname><given-names>D</given-names></name>, &#x00026; <name><surname>Hoopes</surname><given-names>GS</given-names></name> (<year>1975</year>). <article-title>A continuous flow condensation nucleus counter</article-title>. <source>Journal of Aerosol Science</source>, <volume>6</volume>(<issue>1</issue>), <fpage>1</fpage>&#x02013;<lpage>7</lpage>. <pub-id pub-id-type="doi">10.1016/0021-8502(75)90036-1</pub-id>.</mixed-citation></ref><ref id="R33"><mixed-citation publication-type="journal"><name><surname>Sorooshian</surname><given-names>A</given-names></name>, <name><surname>Brechtel</surname><given-names>FJ</given-names></name>, <name><surname>Ma</surname><given-names>Y</given-names></name>, <name><surname>Weber</surname><given-names>RJ</given-names></name>, <name><surname>Corless</surname><given-names>A</given-names></name>, <name><surname>Flagan</surname><given-names>RC</given-names></name>, &#x00026; <name><surname>Seinfeld</surname><given-names>JH</given-names></name> (<year>2006</year>). <article-title>Modeling and characterization of a particle-into-liquid sampler (PILS)</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>40</volume>(<issue>6</issue>), <fpage>396</fpage>&#x02013;<lpage>409</lpage>. <pub-id pub-id-type="doi">10.1080/02786820600632282</pub-id></mixed-citation></ref><ref id="R34"><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>D</given-names></name>, <name><surname>Jiang</surname><given-names>J</given-names></name>, <name><surname>Deng</surname><given-names>J</given-names></name>, <name><surname>Li</surname><given-names>Y</given-names></name>, &#x00026; <name><surname>Hao</surname><given-names>J</given-names></name> (<year>2020</year>). <article-title>A sampler for collecting fine particles into liquid suspensions</article-title>. <source>Aerosol and Air Quality Research</source>, <volume>20</volume>(<issue>3</issue>), <fpage>654</fpage>&#x02013;<lpage>662</lpage>. <pub-id pub-id-type="doi">10.4209/aaqr.2019.12.0616</pub-id></mixed-citation></ref><ref id="R35"><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>J</given-names></name>, <name><surname>McNeill</surname><given-names>VF</given-names></name>, <name><surname>Collins</surname><given-names>DR</given-names></name>, &#x00026; <name><surname>Flagan</surname><given-names>RC</given-names></name> (<year>2002</year>). <article-title>Fast mixing condensation nucleus counter: Application to rapid scanning differential mobility analyzer measurements</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>36</volume>(<issue>6</issue>), <fpage>678</fpage>&#x02013;<lpage>689</lpage>. <pub-id pub-id-type="doi">10.1080/02786820290038366</pub-id></mixed-citation></ref><ref id="R36"><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>D</given-names></name>, <name><surname>Pakbin</surname><given-names>P</given-names></name>, <name><surname>Saffari</surname><given-names>A</given-names></name>, <name><surname>Shafer</surname><given-names>MM</given-names></name>, <name><surname>Schauer</surname><given-names>JJ</given-names></name>, &#x00026; <name><surname>Sioutas</surname><given-names>C</given-names></name> (<year>2013</year>). <article-title>Development and evaluation of a high-volume aerosol-into-liquid collector for fine and ultrafine particulate matter</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>47</volume>(<issue>11</issue>), <fpage>1226</fpage>&#x02013;<lpage>1238</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2013.830693</pub-id></mixed-citation></ref><ref id="R37"><mixed-citation publication-type="journal"><name><surname>Weber</surname><given-names>RJ</given-names></name>, <name><surname>Orsini</surname><given-names>D</given-names></name>, <name><surname>Daun</surname><given-names>Y</given-names></name>, <name><surname>Lee</surname><given-names>Y-N</given-names></name>, <name><surname>Klotz</surname><given-names>PJ</given-names></name>, &#x00026; <name><surname>Brechtel</surname><given-names>F</given-names></name> (<year>2001</year>). <article-title>A particle-into-liquid collector for rapid measurement of aerosol bulk chemical composition</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>35</volume>(<issue>3</issue>), <fpage>718</fpage>&#x02013;<lpage>727</lpage>. <pub-id pub-id-type="doi">10.1080/02786820152546761</pub-id></mixed-citation></ref><ref id="R38"><mixed-citation publication-type="journal"><name><surname>Wubulihairen</surname><given-names>M</given-names></name>, <name><surname>Sabrina</surname><given-names>Jiang, Y.</given-names></name>, &#x00026; <name><surname>Ning</surname><given-names>Z</given-names></name> (<year>2015</year>). <article-title>Prototype development and laboratory evaluation of an aerosol to hydrosol sampler</article-title>. <source>Aerosol and Air Quality Research</source>, <volume>15</volume>(<issue>3</issue>), <fpage>776</fpage>&#x02013;<lpage>785</lpage>. <pub-id pub-id-type="doi">10.4209/aaqr.2014.08.0175</pub-id></mixed-citation></ref><ref id="R39"><mixed-citation publication-type="journal"><name><surname>Zervaki</surname><given-names>O</given-names></name>, <name><surname>Dionysiou</surname><given-names>DD</given-names></name>, &#x00026; <name><surname>Kulkarni</surname><given-names>P</given-names></name> (<year>2024</year>). <article-title>Compact, high-flow, water-based, turbulent-mixing, condensation aerosol concentrator for collection of spot samples</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>58</volume>(<issue>8</issue>), <fpage>889</fpage>&#x02013;<lpage>901</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2024.2361050</pub-id><pub-id pub-id-type="pmid">39376592</pub-id>
</mixed-citation></ref><ref id="R40"><mixed-citation publication-type="journal"><name><surname>Zervaki</surname><given-names>O</given-names></name>, <name><surname>Stump</surname><given-names>B</given-names></name>, <name><surname>Keady</surname><given-names>P</given-names></name>, <name><surname>Dionysiou</surname><given-names>DD</given-names></name>, &#x00026; <name><surname>Kulkarni</surname><given-names>P</given-names></name> (<year>2023</year>). <article-title>NanoSpot TM collector for aerosol sample collection for direct microscopy and spectroscopy analysis</article-title>. <source>Aerosol Science &#x00026; Technology</source>, <volume>57</volume>(<issue>4</issue>), <fpage>342</fpage>&#x02013;<lpage>354</lpage>. <pub-id pub-id-type="doi">10.1080/02786826.2023.2167648</pub-id><pub-id pub-id-type="pmid">37284690</pub-id>
</mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Fig. 1.</label><caption><p id="P51">3D view of the TCALC apparatus. (1) Saturator, (2) Resistance Temperature Detector (RTD), (3) Cartridge heater, (4) Mixing region, (5) Droplet growth region, (6) Thermoelectric cooler (TEC), (7) Heatsink, (8) Fan, (9) Durapore<sup>&#x000ae;</sup> PVDF membrane, (10) Outlet of condensed water, (11) Focusing nozzle, (12) Droplet impactor, (13) Collection vial.</p></caption><graphic xlink:href="nihms-2037907-f0001" position="float"/></fig><fig position="float" id="F2"><label>Fig. 2.</label><caption><p id="P52">Experimental setup used for measurement of droplet growth efficiency obtained through the mixing and droplet growth region of the TCALC.</p></caption><graphic xlink:href="nihms-2037907-f0002" position="float"/></fig><fig position="float" id="F3"><label>Fig. 3.</label><caption><p id="P53">Droplet growth efficiency <inline-formula><mml:math id="M96" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> measured as a function of the saturator temperature (<inline-formula><mml:math id="M97" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, &#x000b0;C) for an aerosol flowrate of 8, 9 and 10 L min<sup>&#x02212;1</sup>. 100-nm-diameter NaCl particles were used (<inline-formula><mml:math id="M98" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>23.6</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>24.9</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M99" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>=</mml:mo><mml:mn>45.8</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>51.5</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M100" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>0</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>). The error bars indicate the standard deviation of three repeat measurements.</p></caption><graphic xlink:href="nihms-2037907-f0003" position="float"/></fig><fig position="float" id="F4"><label>Fig. 4.</label><caption><p id="P54">Droplet growth efficiency <inline-formula><mml:math id="M101" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> measured as a function of (a) the seed particle aerodynamic diameter (<inline-formula><mml:math id="M102" display="inline"><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:math></inline-formula>, nm) and (b) the operation time (min), for a fixed aerosol flowrate of 8 L min<sup>&#x02212;1 <inline-formula><mml:math id="M103" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>75</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula></sup>, 9 L min<sup>&#x02212;1</sup>
<inline-formula><mml:math id="M104" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>80</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and 10 L min<sup>&#x02212;1 <inline-formula><mml:math id="M105" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula></sup>. NaCl particles were used. 100-nm-diameter particles were used for the evaluation of the impact of the operation time (<inline-formula><mml:math id="M106" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>22.5</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>25.3</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>,<inline-formula><mml:math id="M107" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>=</mml:mo><mml:mn>46.6</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>56</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula>). The error bars in (a) indicate the standard deviation of three repeat measurements.</p></caption><graphic xlink:href="nihms-2037907-f0004" position="float"/></fig><fig position="float" id="F5"><label>Fig. 5.</label><caption><p id="P55">Droplet growth efficiency <inline-formula><mml:math id="M108" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> measured as a function of the growth tube temperature (<inline-formula><mml:math id="M109" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula>, &#x000b0;C) for an aerosol flowrate of 8 L min<sup>&#x02212;1 <inline-formula><mml:math id="M110" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>75</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula></sup>, 9 L min<sup>&#x02212;1</sup>
<inline-formula><mml:math id="M111" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>80</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> and 10 L min<sup>&#x02212;1 <inline-formula><mml:math id="M112" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula></sup>. 100-nm-diameter NaCl particles were used (<inline-formula><mml:math id="M113" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>23.7</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>24.9</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M114" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>=</mml:mo><mml:mn>46.5</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>52.2</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula>). The error bars indicate the standard deviation of three repeat measurements.</p></caption><graphic xlink:href="nihms-2037907-f0005" position="float"/></fig><fig position="float" id="F6"><label>Fig. 6.</label><caption><p id="P56">Droplet growth efficiency <inline-formula><mml:math id="M115" display="inline"><mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>d</mml:mi></mml:msub><mml:mo>&#x0003e;</mml:mo><mml:mn>1.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x003bc;m</mml:mo></mml:mrow></mml:mfenced></mml:mrow></mml:math></inline-formula> measured as a function of the aerosol inlet relative humidity (%) for an aerosol flowrate of 8, 9 and 10 L min<sup>&#x02212;1</sup>. 100-nm-diameter NaCl particles were used (<inline-formula><mml:math id="M116" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>23.6</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>25.4</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M117" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>). The error bars indicate the standard deviation of three repeat measurements.</p></caption><graphic xlink:href="nihms-2037907-f0006" position="float"/></fig><fig position="float" id="F7"><label>Fig. 7.</label><caption><p id="P57">Collection efficiency of crystalline silica particles as a function of the number concentration (<inline-formula><mml:math id="M118" display="inline"><mml:mrow><mml:mi>R</mml:mi><mml:mi>H</mml:mi><mml:mo>=</mml:mo><mml:mn>40.2</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>57.4</mml:mn><mml:mi>%</mml:mi></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M119" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>22.3</mml:mn><mml:mo>&#x02013;</mml:mo><mml:mn>22.8</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M120" display="inline"><mml:mrow><mml:msub><mml:mi>Q</mml:mi><mml:mi>a</mml:mi></mml:msub><mml:mo>=</mml:mo><mml:mn>10</mml:mn><mml:mspace width="0.5em"/><mml:mtext>L</mml:mtext><mml:mspace width="0.5em"/><mml:msup><mml:mrow><mml:mtext>min</mml:mtext></mml:mrow><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:math></inline-formula>, <inline-formula><mml:math id="M121" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>s</mml:mi><mml:mi>a</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>85</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>,<inline-formula><mml:math id="M122" display="inline"><mml:mrow><mml:msub><mml:mi>T</mml:mi><mml:mrow><mml:mi>g</mml:mi><mml:mi>t</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>0</mml:mn><mml:mspace width="0.5em"/><mml:mo>&#x000b0;</mml:mo><mml:mtext>C</mml:mtext></mml:mrow></mml:math></inline-formula>). The error bars, too small to be clearly visible, indicate the standard deviation of three repeat measurements.</p></caption><graphic xlink:href="nihms-2037907-f0007" position="float"/></fig><fig position="float" id="F8"><label>Fig. 8.</label><caption><p id="P58">Comparison of crystalline silica particulate mass (&#x003bc;g) collected through the TCALC and reference 37-mm-diameter polycarbonate filters. The error bars represent the standard deviation of three gravimetric repeat measurements. The dashed line represents the linear fit of the experimental data.</p></caption><graphic xlink:href="nihms-2037907-f0008" position="float"/></fig></floats-group></article>