<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.3 20210610//EN" "JATS-archivearticle1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">0261412</journal-id><journal-id journal-id-type="pubmed-jr-id">20783</journal-id><journal-id journal-id-type="nlm-ta">Appl Ergon</journal-id><journal-id journal-id-type="iso-abbrev">Appl Ergon</journal-id><journal-title-group><journal-title>Applied ergonomics</journal-title></journal-title-group><issn pub-type="ppub">0003-6870</issn><issn pub-type="epub">1872-9126</issn></journal-meta><article-meta><article-id pub-id-type="pmid">34507084</article-id><article-id pub-id-type="pmc">11627332</article-id><article-id pub-id-type="doi">10.1016/j.apergo.2021.103579</article-id><article-id pub-id-type="manuscript">HHSPA1970133</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Manufacturing worker perceptions of using wearable inertial sensors for multiple work shifts</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Zhang</surname><given-names>Xuanxuan</given-names></name><degrees>Ph.D.</degrees><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0001-5054-1364</contrib-id><aff id="A1">Department of Applied Science and Technology, College of Engineering and Computer Sciences, Marshall University, Huntington, WV</aff><aff id="A2">Department of Industrial and System Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL</aff></contrib><contrib contrib-type="author"><name><surname>Schall</surname><given-names>Mark C.</given-names><suffix>Jr.</suffix></name><degrees>Ph.D.</degrees><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-2516-0292</contrib-id><aff id="A3">Department of Industrial and System Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL</aff></contrib><contrib contrib-type="author"><name><surname>Chen</surname><given-names>Howard</given-names></name><degrees>Ph.D.</degrees><aff id="A4">Department of Mechanical Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL</aff></contrib><contrib contrib-type="author"><name><surname>Gallagher</surname><given-names>Sean</given-names></name><degrees>Ph.D.</degrees><aff id="A5">Department of Industrial and System Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL</aff></contrib><contrib contrib-type="author"><name><surname>Davis</surname><given-names>Gerard A.</given-names></name><degrees>Ph.D.</degrees><aff id="A6">Department of Industrial and System Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL</aff></contrib><contrib contrib-type="author"><name><surname>Sesek</surname><given-names>Richard</given-names></name><degrees>Ph.D.</degrees><aff id="A7">Department of Industrial and System Engineering, Samuel Ginn College of Engineering, Auburn University, Auburn, AL</aff></contrib></contrib-group><author-notes><corresp id="CR1"><label>*</label>corresponding author <email>mark-schall@auburn.edu</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>22</day><month>11</month><year>2024</year></pub-date><pub-date pub-type="ppub"><month>1</month><year>2022</year></pub-date><pub-date pub-type="epub"><day>07</day><month>9</month><year>2021</year></pub-date><pub-date pub-type="pmc-release"><day>09</day><month>12</month><year>2024</year></pub-date><volume>98</volume><fpage>103579</fpage><lpage>103579</lpage><abstract id="ABS1"><p id="P1">Wearable inertial sensors may be used to objectively quantify exposure to some physical risk factors associated with musculoskeletal disorders. However, concerns regarding their potential negative effects on user safety and satisfaction remain. This study characterized the self-reported daily (dis)comfort, distraction, and burden associated with wearing inertial sensors on the upper arms, trunk, and dominant wrist of 31 manufacturing workers collected over 15 full work shifts. Results indicated that the workers considered the devices as generally comfortable to wear, not distracting, and not burdensome to use. Exposure to non-neutral postures (discomfort, right arm, beta=0.02; trunk, beta=&#x02212;0.01), non-cyclic tasks (distraction, beta =&#x02212;0.26), and higher body mass indices (discomfort, beta=0.05; distraction, beta=0.02) contributed to statistically significant (<italic toggle="yes">p</italic> &#x0003c; 0.05), albeit practically small increases in undesirable ratings. For instance, for each additional percentage of time working with the right arm elevated &#x02265;60&#x000b0;, self-reported discomfort ratings increased 0.02cm on a standard 10cm visual analog scale. Female workers reported less discomfort and distraction while wearing the sensors at work than males (discomfort, beta=&#x02212;0.93; distraction, beta=&#x02212;0.3). In general, the low ratings of discomfort, distraction, and burden associated with wearing the devices during work suggests that inertial sensors may be suitable for extended use among manufacturing workers.</p></abstract><kwd-group><kwd>wearables</kwd><kwd>user experience</kwd><kwd>musculoskeletal disorders</kwd><kwd>inertial measurement unit</kwd><kwd>exposure assessment</kwd><kwd>field measurement</kwd></kwd-group></article-meta></front><body><sec id="S1"><label>1.</label><title>Introduction</title><p id="P2">The manufacturing sector reported the second highest number of reported cases and the sixth highest incidence rate of nonfatal occupational injuries and illnesses among all U.S. industries in 2019 (<xref rid="R50" ref-type="bibr">USBLS, 2020a</xref>). Musculoskeletal disorders (MSDs) accounted for approximately 30% of all lost workdays, the third highest number of reported cases, and the fifth highest incidence rate of all nonfatal occupational injury and illness cases for full-time workers in the United States in 2018 (<xref rid="R51" ref-type="bibr">USBLS, 2020b</xref>). Approximately 10% of workers in automotive assembly-based production report MSDs resulting from exposure to physical risk factors such as working in non-neutral postures and high movement speeds every year (<xref rid="R30" ref-type="bibr">OSHA, 2014</xref>).</p><p id="P3">Accurate and objective quantification of exposure to physical risk factors associated with MSDs is needed for ergonomists to improve occupational safety and health (<xref rid="R26" ref-type="bibr">Mathiassen et al., 2015</xref>). Direct measurement methods provide more precise and objective exposure information when compared to self-report and observational approaches (<xref rid="R7" ref-type="bibr">David, 2005</xref>; <xref rid="R44" ref-type="bibr">Spielholz et al., 2001</xref>; <xref rid="R47" ref-type="bibr">Teschke et al., 2009</xref>; <xref rid="R54" ref-type="bibr">Winkel and Mathiassen, 1994</xref>). Wearable inertial sensors are electromechanical devices typically comprised of a combination of accelerometers, gyroscopes, and magnetometers that directly measure the linear acceleration, rotational velocity, and heading of an object in space. They represent an extension of the single-axis inclinometers used for decades by ergonomists by measuring the information necessary to determine the three-dimensional orientation of an object in space; although they are often applied in work settings as more accurate inclinometers (<xref rid="R6" ref-type="bibr">Chen et al., 2020</xref>) or for activity recognition and energy expenditure estimation purposes (i.e., a physical activity monitor) (<xref rid="R2" ref-type="bibr">Beeler et al., 2018</xref>; <xref rid="R27" ref-type="bibr">McNamara et al., 2016</xref>; <xref rid="R38" ref-type="bibr">Schall Jr et al., 2016a</xref>; <xref rid="R48" ref-type="bibr">Thiese, 2014</xref>).</p><p id="P4">Although several studies have used inertial sensors to directly measure physical exposure information (e.g., kinematics, physiological biometrics) in the manufacturing sector (<xref rid="R12" ref-type="bibr">Greco et al., 2019</xref>; <xref rid="R13" ref-type="bibr">Hansson et al., 2010</xref>; <xref rid="R16" ref-type="bibr">Ji and Piovesan, 2020</xref>; <xref rid="R19" ref-type="bibr">Kersten and Fethke, 2019</xref>; <xref rid="R25" ref-type="bibr">Maman et al., 2017</xref>; <xref rid="R43" ref-type="bibr">Schall Jr et al., 2021</xref>; <xref rid="R45" ref-type="bibr">Tao et al., 2018</xref>; <xref rid="R55" ref-type="bibr">Zhang et al., 2019</xref>), the sensors have not been broadly adopted by occupational safety and health practitioners. Safety and health practitioners have reported interest in applying wearable sensors among their workforces for assessing exposure to physical risk factors in the work environment (<xref rid="R35" ref-type="bibr">Reid et al., 2017</xref>; <xref rid="R42" ref-type="bibr">Schall Jr et al., 2018</xref>). However, practitioners and employees have valid concerns, including safety issues arising as a result of wearing potentially uncomfortable, distracting, and/or burdensome sensors (<xref rid="R15" ref-type="bibr">Jacobs et al., 2019</xref>; <xref rid="R21" ref-type="bibr">le Feber et al., 2020</xref>; <xref rid="R35" ref-type="bibr">Reid et al., 2017</xref>; <xref rid="R42" ref-type="bibr">Schall Jr et al., 2018</xref>; <xref rid="R55" ref-type="bibr">Zhang et al., 2019</xref>).</p><p id="P5">One gap in the scientific literature contributing to the lack of adoption of wearable inertial sensors as exposure assessment tools in the manufacturing sector is limited information regarding worker perceptions of using wearable inertial sensors in the workplace, particularly across multiple work shifts. To address this gap, we (i) characterized the self-reported daily discomfort, distraction and burden associated with using wearable inertial sensors among manufacturing workers completing standard production activities over 15 full work shifts, and (ii) evaluated how different personal (e.g., sex, body mass index [BMI]) and work characteristics (e.g., cyclic vs. non-cyclic work categorization; perceptions of stress; exposure to kinematic risk factors) affected their ratings.</p></sec><sec id="S2"><label>2.</label><title>Methods</title><sec id="S3"><label>2.1</label><title>Participant Recruitment and Data Collection</title><p id="P6">Thirty-six healthy manufacturing workers were enrolled in this study following procedures described in <xref rid="R43" ref-type="bibr">Schall et al. (2021)</xref>. In short, participants were categorized into &#x0201c;cyclic&#x0201d; or &#x0201c;non-cyclic&#x0201d; work groups (n=18 per group) based on their predominant work responsibilities. Participants in the &#x0201c;cyclic&#x0201d; group primarily performed repetitive, assembly-based production tasks characterized by cycle times of less than approximately three minutes in duration (consistent with <xref rid="R31" ref-type="bibr">Paulsen et al. [2014</xref>]). Participants in the &#x0201c;non-cyclic&#x0201d; group primarily completed non-routinized tasks (e.g., maintenance, stocking workstations). Each participant was between 19 and 65 years of age, and recruited according to Auburn University Institutional Review Board approved procedures. All participants provided written informed consent.</p><p id="P7">The participants each wore up to four ActiGraph GT9X Links (ActiGraph, Pensacola, Florida, USA) secured to the body using elastic hook-and-loop fastener straps for 15 weekday shifts in a manner similar to previous studies (<xref rid="R40" ref-type="bibr">Schall Jr et al., 2014</xref>; <xref rid="R41" ref-type="bibr">Schall Jr et al., 2016c</xref>; <xref rid="R43" ref-type="bibr">Schall Jr et al., 2021</xref>). One device was secured over the clothes to the anterior torso over the breast bone approximately between the sternal notch and the xyphoid process. Participants could adjust the positioning of the sensor for comfort. Another was secured to the lateral aspect of each upper arm halfway between the lateral epicondyle and the acromion over the clothes or on the skin (based on participant preference). Finally, one device was also worn on the skin around the dominant wrist. Five participants did not wear the wrist sensor due to potential safety concerns (e.g., prospect of working with hands near machinery). Each device was wrapped in hypoallergenic, cohesive bandages to secure the sensor to the elastic hook-and-loop fastener strap and protect the sensor from environmental hazards (e.g., lubricants).</p><p id="P8">Immediately after the sensors were secured to each participant, a calibration procedure was performed at the beginning of each shift. It included standing in a neutral posture, performing three trunk bends to approximately 30&#x02013;60&#x000b0; of trunk flexion, and three lateral arms raises from a neutral posture to approximately 90&#x000b0; relative to gravity (see more details in <xref rid="R43" ref-type="bibr">Schall et al. [2021</xref>]). The time that the calibration procedure began was reviewed in MATLAB (2017b, Mathworks, Natick, MA) and used to identify the beginning of data collection. Participants proceeded with their normal work shift after completing the calibration procedure.</p><p id="P9">During each work shift, each participant was asked to record the number of hours they spent performing their work activities (i.e., tasks and breaks) in a daily work log. The daily work log included 10cm visual analog scales (VAS). Participants were asked to rate the &#x0201c;stress&#x0201d; experienced for each logged work activity from a score of 0 indicating &#x0201c;no stress&#x0201d; to a score of 10 for &#x0201c;very stressful&#x0201d; immediately following completion of the task on separate VASs. At the end of the work shift, participants recorded their perceived discomfort, distraction, and burden associated with using the full complement of sensors they wore throughout the entire shift. Verbal anchors of &#x0201c;completely comfortable&#x0201d;, &#x0201c;no distraction&#x0201d;, and &#x0201c;no burden&#x0201d; were attributed to a score of 0, while a score of 10 represented the devices being &#x0201c;as uncomfortable as possible&#x0201d;, a &#x0201c;complete distraction&#x0201d;, or &#x0201c;as burdensome as possible&#x0201d;. At the conclusion of each shift, the raw inertial sensor data were downloaded to a computer using ActiLife software (version 6.13.3, ActiGraph, LLC, Pensacola, FL) and exported to comma-separated files.</p></sec><sec id="S4"><label>2.2</label><title>Data Processing and Feature Selection</title><p id="P10">Upper arm elevation, trunk inclination about the sagittal plane (i.e., flexion/extension), and the magnitude of the associated movement speeds (i.e., the absolute value of velocities) for each work shift were summarized following the procedures described in <xref rid="R43" ref-type="bibr">Schall et al. (2021)</xref> to be consistent with several field-based studies (<xref rid="R17" ref-type="bibr">Kazmierczak et al., 2005</xref>; <xref rid="R19" ref-type="bibr">Kersten and Fethke, 2019</xref>; <xref rid="R52" ref-type="bibr">Wahlstr&#x000f6;m et al., 2016</xref>; <xref rid="R53" ref-type="bibr">Wahlstr&#x000f6;m et al., 2010</xref>). In the current study, three participants were excluded because over 25% of their trunk data were missing due to data collection failure or because they chose to not wear the sensors for safety or personal reasons. One participant in the cyclic group was excluded from the analysis due to changing job titles and primary work activity classification after the 10<sup>th</sup> shift of data collection. One participant withdrew from the non-cyclic group on the first day of data collection and was excluded.</p><p id="P11">For the remaining 31 participants, Multiple Imputation (MI) and Expectation-Maximization (EM) algorithms (see <xref rid="R3" ref-type="bibr">Bennett, 2001</xref>) were used to impute any missing ratings of stress (1.9% of shifts), discomfort, distraction, and burden (4.9% of shifts), and missing exposure measurements as a result of data collection failures (0.9% for the left arm, 0.4% for right arm, and 5.8% for the trunk). We performed five iterations of MI in accordance with the rate of missing data (<xref rid="R37" ref-type="bibr">Royston and White, 2011</xref>). The EM algorithm is a two-step iterative approach that estimates the maximum likelihood parameters by repeating Expectation (E-step) and Maximization (M-step) steps in parametric models. Feature selection techniques were then used to identify the most informative variables for inclusion in our inferential statistical models using discomfort, distraction, or burden as the response variable. Specifically, ReliefF Attribute Evaluation was carried out in WEKA 3.8.0 to examine the rank importance of predictors and improve prediction accuracy. The ReliefF algorithm is an extension of Relief-based algorithms (RBAs), which are filter-style feature selection algorithms. These algorithms aim to maximize prediction accuracy and computational efficiency that have been applied in many different areas of study for both classification and regression analyses (<xref rid="R49" ref-type="bibr">Urbanowicz et al., 2018</xref>). WEKA 3.8.0 is an open-source software written in the Java programming language with a collection of machine learning algorithms for data mining (<xref rid="R10" ref-type="bibr">Frank et al., 2009</xref>).</p><p id="P12">Variables were selected based on their average merit and rank where merit is a measure of the importance and usefulness of a feature and rank is the order of importance or usefulness assigned based on the merit scoring function (<xref rid="R1" ref-type="bibr">Adams et al., 2017</xref>). The larger the value of the merit, the higher the rank of the attribute. The average value of merit and average rank from ten iterations was used from ten-fold cross-validation. The feature selection process seeks to eliminate irrelevant or redundant features, reduce the training time required to build a statistical model, and optimize predictive performance (<xref rid="R29" ref-type="bibr">Onan and Koruko&#x0011f;lu, 2017</xref>).</p><p id="P13">A Pearson correlation coefficient matrix was generated for diagnosing occurrences of multicollinearity. Correlation coefficients &#x02265; 0.8 were considered as the occurrence of multicollinearity. In total, 27 candidate predictors were considered:</p><list list-type="bullet" id="L1"><list-item><p id="P14">Age</p></list-item><list-item><p id="P15">Body mass index (BMI)</p></list-item><list-item><p id="P16">Sex</p></list-item><list-item><p id="P17">Time-weighted average stress ratings calculated using the reported task durations and stress ratings from the self-reported logs</p></list-item><list-item><p id="P18">Work category (i.e., cyclic vs. non-cyclic)</p></list-item><list-item><p id="P19">Eight kinematic exposure variables for each arm, which included:
<list list-type="bullet" id="L2"><list-item><p id="P20">Mean amplitude of the time-series arm elevation waveform over the duration of each shift</p></list-item><list-item><p id="P21">Mean amplitude of the time-series movement speed waveform over the duration of each shift</p></list-item><list-item><p id="P22">The 90th percentile of the time-series arm elevation waveform over the duration of each shift</p></list-item><list-item><p id="P23">The 90th percentile of the time-series movement speed waveform over the duration of each shift</p></list-item><list-item><p id="P24">The percentage of time moving at low movement speeds (&#x0003c; 5&#x000b0;/s)</p></list-item><list-item><p id="P25">The percentage of time moving at high movement speeds (&#x02265; 90&#x000b0;/s)</p></list-item><list-item><p id="P26">The percentage of time with the arm elevated &#x02265; 60&#x000b0; degree (left = LA60+; right = RA60+)</p></list-item><list-item><p id="P27">The percentage of time with the arm in a neutral posture (&#x0003c; 20&#x000b0;) and moving at a low speed (&#x0003c; 5&#x000b0;/s) (left = LANLS; right = RANLS)</p></list-item></list></p></list-item><list-item><p id="P28">Six kinematic exposure variables for the trunk, which included:
<list list-type="bullet" id="L3"><list-item><p id="P29">Mean amplitude of the time-series trunk flexion/extension waveform over the duration of each shift</p></list-item><list-item><p id="P30">Mean amplitude of the time-series movement speed waveform over the duration of each shift</p></list-item><list-item><p id="P31">The 90th percentile of the time-series trunk flexion/extension waveform over the duration of each shift (FE90P)</p></list-item><list-item><p id="P32">The 90th percentile of the time-series movement speed waveform over the duration of each shift</p></list-item><list-item><p id="P33">The percentage of time with the trunk moving &#x0003c; 5 &#x000b0;/s</p></list-item><list-item><p id="P34">The percentage of time with the trunk moving &#x02265; 90 &#x000b0;/s</p></list-item></list></p></list-item></list><p id="P35">Nine variables were identified as predictors for inclusion in our linear models based on the feature selection procedure: age, sex, BMI (kg/m<sup>2</sup>), time-weighted average stress ratings, work category (i.e., cyclic vs. non-cyclic), the percentage of time with an arm elevated &#x02265; 60&#x000b0; (left = LA60+; right = RA60+), the percentage of time with the right arm in a neutral posture (&#x0003c; 20&#x000b0;) and moving at a low speed (&#x0003c; 5&#x000b0;/s) (RANLS), and the 90th percentile of trunk flexion/extension (FE90P) (<xref rid="T1" ref-type="table">Table 1</xref>). These predictors had (i) positive average merit values in all three models; and (ii) were not highly correlated (i.e., &#x02265; 0.8) with other predictors. If two candidate predictors had positive average merit values and were correlated, the predictor with the higher average rank value was selected for inclusion in each model.</p></sec><sec id="S5"><label>2.3</label><title>Statistical Analysis</title><p id="P36">Three different generalized linear models were applied to investigate the effects of work category (i.e., cyclic vs. non-cyclic), work stress, the kinematic exposure variables, and personal characteristics on self-reported discomfort, distraction, and burden ratings. We also included the shift on which the sensor wearing experience was provided to evaluate the trend of subjective ratings over the 15 sampled work shifts. It was hypothesized that participants would become more comfortable, less distracted, and less burdened by the sensors as time went on. The generalized structure of these models was as follows:
<disp-formula id="FD1">
<mml:math id="M1" display="block"><mml:mrow><mml:msub><mml:mtext>Y</mml:mtext><mml:mtext>ij</mml:mtext></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>1</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>1</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>2</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>2</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>3</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>3</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>4</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>4</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>5</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>5</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>6</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>6</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>7</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>7</mml:mn></mml:mrow></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mn>8</mml:mn></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>8</mml:mn></mml:mrow></mml:msub><mml:mo>&#x02026;</mml:mo><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b2;</mml:mtext><mml:mtext>k</mml:mtext></mml:msub><mml:msub><mml:mtext>X</mml:mtext><mml:mtext>ijk</mml:mtext></mml:msub><mml:mo>+</mml:mo><mml:msub><mml:mtext>&#x003b5;</mml:mtext><mml:mtext>ij</mml:mtext></mml:msub><mml:mspace linebreak="newline"/><mml:mo>,</mml:mo><mml:mtext>i</mml:mtext><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo>,</mml:mo><mml:mspace width="0.5em"/><mml:mo>&#x02026;</mml:mo><mml:mo>,</mml:mo><mml:mspace width="0.5em"/><mml:mtext>n</mml:mtext><mml:mo>;</mml:mo><mml:mtext>j</mml:mtext><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo>,</mml:mo><mml:mspace width="0.5em"/><mml:mo>&#x02026;</mml:mo><mml:mo>,</mml:mo><mml:mspace width="0.5em"/><mml:mtext>m</mml:mtext><mml:mo>;</mml:mo><mml:mtext>n</mml:mtext><mml:mo>=</mml:mo><mml:mn>31</mml:mn><mml:mo>,</mml:mo><mml:mtext>m</mml:mtext><mml:mo>=</mml:mo><mml:mn>15</mml:mn><mml:mo>,</mml:mo><mml:mtext>k</mml:mtext><mml:mo>=</mml:mo><mml:mn>11</mml:mn></mml:mrow></mml:math>
</disp-formula></p><p id="P37">Where <inline-formula><mml:math id="M2" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>1</mml:mn></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:math></inline-formula> for all <inline-formula><mml:math id="M3" display="inline"><mml:mrow><mml:mtext>i</mml:mtext></mml:mrow></mml:math></inline-formula> and <inline-formula><mml:math id="M4" display="inline"><mml:mrow><mml:mtext>j</mml:mtext></mml:mrow></mml:math></inline-formula>;</p><p id="P38"><inline-formula><mml:math id="M5" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>2</mml:mn></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mtext>t</mml:mtext><mml:mtext>j</mml:mtext></mml:msub></mml:mrow></mml:math></inline-formula>, the shift on which the sensor wearing experience was rated;</p><p id="P39"><inline-formula><mml:math id="M6" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>3</mml:mn></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:math></inline-formula> if the i<sup>th</sup> participant was categorized as a cyclic worker and 0 if non-cyclic;</p><p id="P40"><inline-formula><mml:math id="M7" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>4</mml:mn></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mn>1</mml:mn></mml:mrow></mml:math></inline-formula> if the i<sup>th</sup> participant was female and 0 if male;</p><p id="P41"><inline-formula><mml:math id="M8" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>5</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = the self-reported score of work-related stress;</p><p id="P42"><inline-formula><mml:math id="M9" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>6</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = the body mass index (BMI) value of each participant;</p><p id="P43"><inline-formula><mml:math id="M10" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>7</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = the age of each participant;</p><p id="P44"><inline-formula><mml:math id="M11" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>8</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = percentage of time with the left arm elevated &#x02265; 60&#x000b0; (LA60+);</p><p id="P45"><inline-formula><mml:math id="M12" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>9</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = percentage of time with the right arm elevated &#x02265; 60&#x000b0; (RA60+);</p><p id="P46"><inline-formula><mml:math id="M13" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>10</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = percentage of time with the right arm elevated &#x0003c; 20&#x000b0; and moving &#x0003c; 5&#x000b0;/s (RANLS);</p><p id="P47"><inline-formula><mml:math id="M14" display="inline"><mml:mrow><mml:msub><mml:mtext>X</mml:mtext><mml:mrow><mml:mtext>ij</mml:mtext><mml:mn>11</mml:mn></mml:mrow></mml:msub></mml:mrow></mml:math></inline-formula> = the 90th percentile of trunk flexion/extension (FE90P);</p><p id="P48">We assume that <inline-formula><mml:math id="M15" display="inline"><mml:mrow><mml:mtext>&#x003b5;ij</mml:mtext><mml:mo>~</mml:mo><mml:mtext>N</mml:mtext><mml:mo>(</mml:mo><mml:mn>0</mml:mn><mml:mo>,</mml:mo><mml:msup><mml:mtext>&#x003c3;</mml:mtext><mml:mn>2</mml:mn></mml:msup><mml:mo>)</mml:mo></mml:mrow></mml:math></inline-formula>.</p><p id="P49">Each model was built and processed in SAS software (version 9.4; SAS Institute Inc., Cary, NC, USA) using the PROC MIXED procedure. Residual Maximum Likelihood (REML) estimation was applied to reduce potential bias. Different types of covariance structures were evaluated based on model fitness using Akaike Information Criterion (AIC). A Heterogeneous Autoregressive (ARH(1)) structure was selected for the discomfort rating model (AIC=1234.1), while Unstructured (UN) was selected for the distraction rating (AIC=877.0) and burden rating models (AIC=621.2). 95% two-sided confidence intervals provide an overview of the dispersion of the beta coefficient for each predictor.</p></sec></sec><sec id="S6"><label>3.</label><title>Results</title><p id="P50">Observations from 31 participants were included in the statistical analysis (<xref rid="T2" ref-type="table">Table 2</xref>). Only one participant (in the non-cyclic group) was left hand dominant.</p><p id="P51">In general, average self-reported ratings of discomfort (mean = 1.2; SD = 1.6), distraction (mean = 0.9; SD = 1.4), and burden (mean = 0.8; SD = 1.2) were low (<xref rid="F1" ref-type="fig">Figure 1</xref>). Participants spent an average of 7.6% and 7.1% of their time with the left and right arm, respectively, in a non-neutral posture (&#x02265; 60&#x000b0;). Participants worked 14.6% of the time with the right arm in a neutral posture and moving at a low speed (&#x0003c; 5&#x000b0;/s), and the 90th percentile of trunk flexion/extension was 11.1&#x000b0;. The average self-reported stress level experienced at work was low (mean = 1.5; SD = 1.7).</p><p id="P52">Results of the generalized linear models provide information regarding the factors associated with perceptions of wearable sensor discomfort, distraction, and burden (<xref rid="T3" ref-type="table">Table 3</xref>). For the discomfort model, statistically significant factors included the shift (i.e., the first shift of data collection was associated with a statistically significant increase in perceived discomfort, beta=0.82, <italic toggle="yes">p</italic> &#x0003c; 0.05), BMI (beta=0.05, <italic toggle="yes">p</italic> &#x0003c; 0.01), sex (beta for female=&#x02212;0.93, <italic toggle="yes">p</italic> &#x0003c; 0.01), percentage of time with the right arm elevated &#x0003e;60&#x000b0; (beta=0.02, <italic toggle="yes">p</italic> &#x0003c; 0.05), and the 90<sup>th</sup> percentile of the flexion/extension of the trunk (beta=&#x02212;0.01, <italic toggle="yes">p</italic> &#x0003c; 0.05). Significant factors in the distraction model included work category (beta for non-cyclic group = &#x02212;0.26, <italic toggle="yes">p</italic> &#x0003c; 0.01), BMI (beta=0.02, <italic toggle="yes">p</italic> &#x0003c; 0.01), age (beta=0.01, <italic toggle="yes">p</italic> &#x0003c; 0.01), and sex (beta for female=&#x02212;0.3, <italic toggle="yes">p</italic> &#x0003c; 0.05). Significant factors for the burden model included perceptions of stress (beta=0.01, <italic toggle="yes">p</italic> &#x0003c; 0.05) and age (beta=0.01, <italic toggle="yes">p</italic> &#x0003c; 0.01). In general, male participants reported higher mean discomfort than females.</p></sec><sec id="S7"><label>4.</label><title>Discussion</title><p id="P53">Industrial workers and occupational safety and health professionals have expressed concerns regarding using wearable inertial sensors in the workplace, including the potential for discomfort, distraction, and burden among users (<xref rid="R15" ref-type="bibr">Jacobs et al., 2019</xref>; <xref rid="R21" ref-type="bibr">le Feber et al., 2020</xref>; <xref rid="R35" ref-type="bibr">Reid et al., 2017</xref>; <xref rid="R55" ref-type="bibr">Zhang et al., 2019</xref>). This work (i) characterized the self-reported daily discomfort, distraction and burden associated with using wearable inertial sensors among 31 manufacturing workers completing standard production activities over 15 full work shifts, and (ii) evaluated how different personal (e.g., sex; age; BMI) and work characteristics (e.g., cyclic vs. non-cyclic work categorization; perceptions of stress; exposure to kinematic risk factors) affected those ratings. The results indicated that the manufacturing workers that participated in this study reported the devices as generally comfortable to wear, not distracting, and not burdensome to use. Although the results also indicated that some personal and work characteristics played a statistically significant role in increasing undesirable ratings of wearable sensor use, the findings predominantly support the use of wearable inertial sensors in manufacturing environments for multiple full work shifts.</p><p id="P54">Right upper arm elevation was a physical risk factor that played a statistically significant, albeit small role in increasing worker discomfort. In particular, for each additional percentage of time working with the right arm elevated &#x02265;60&#x000b0;, self-reported discomfort ratings increased 0.02cm on a standard 10cm VAS. Frequent raising of the arms may have contributed to reduced blood flow through the arms and increased discomfort unrelated to the use of the wearable devices (<xref rid="R33" ref-type="bibr">Proger and Dexter, 1934</xref>; <xref rid="R36" ref-type="bibr">Rossetti et al., 1994</xref>). Alternatively, this result may have been a function of the decision to use easy-to-secure fastener straps which were selected because of their adjustability and ease of application. Some participants reported loosened sensor straps, and the elastic armband as irritating at the conclusion of their work shifts. Such potential negative consequences of using fastener straps should be considered by safety and health practitioners when performing exposure assessments with wearable inertial sensors. Alternative methods for securing inertial sensors to the body should also be explored, particularly since motion sensors attached to the skin with adhesive tapes may lead to skin irritation and limit the users&#x02019; willingness to use them for prolonged periods (<xref rid="R18" ref-type="bibr">Kent et al., 2015</xref>). Regardless, the small increase in discomfort may be considered practically irrelevant, particularly when considering the relatively small amount of time that the manufacturing workers spent, on average, with their arms elevated.</p><p id="P55">In contrast to the upper arms, participants with greater trunk flexion tended to report slightly less discomfort than peers with less trunk flexion. Participants in this study, however, generally maintained relatively neutral trunk postures relative to workers in several other occupations such as nursing, agriculture, and construction (<xref rid="R9" ref-type="bibr">Fethke et al., 2020</xref>; <xref rid="R11" ref-type="bibr">Granzow et al., 2018</xref>; <xref rid="R22" ref-type="bibr">Lee et al., 2017</xref>; <xref rid="R39" ref-type="bibr">Schall Jr et al., 2016b</xref>; <xref rid="R43" ref-type="bibr">Schall Jr et al., 2021</xref>). As described in <xref rid="R43" ref-type="bibr">Schall et al. (2021)</xref>, the trunk sensor was susceptible to shifting down the sternum towards the xiphoid process due to the use of the fastener straps. This shifting may have contributed to an underestimation of the amount of trunk flexion measured among the workers. Additionally, it is important to note that the VASs completed by participants were broadly attributed to the experience of wearing all four inertial sensors. We did not ask for ratings specific to each body segment. It is possible that increased trunk flexion may have led to increased ratings of localized trunk discomfort. Also, the scale only referred to discomfort associated with the sensor wearing experience. Feelings of physical discomfort related to particular work activities were not evaluated. Future studies may consider separate questions to compare the different sensor rating levels among body segments, or use structured interviews among participants to collect more detailed feedback.</p><p id="P56">Another interesting finding related to discomfort in this study was that manufacturing workers reported greater discomfort on the first shift of data collection relative to the remaining 14 shifts of participation. However, the reports of discomfort were relatively low even on the first day. A possible explanation was that the workers were not accustomed to wearing any devices at work and needed time to adapt. A decreasing trend was observed for discomfort ratings over the 15 shifts suggesting that the workers became more comfortable as time passed. Finding of the results suggest that, in real practice, wearable inertial sensors may be comfortably worn in manufacturing environments for extended durations.</p><p id="P57">Although less commonly studied than discomfort, distraction and/or burden caused by wearable sensors is of concern as they can lead to safety-related incidents (<xref rid="R5" ref-type="bibr">Canina et al., 2006</xref>; <xref rid="R23" ref-type="bibr">Leng et al., 2015</xref>; <xref rid="R24" ref-type="bibr">Liu et al., 2015</xref>). Workers who primarily performed cyclic work tasks reported greater distraction than those who primarily performed non-cyclic work tasks. We previously characterized and compared the kinematics of the cyclic and non-cyclic workers (<xref rid="R43" ref-type="bibr">Schall et al., 2021</xref>). Significant differences were observed for the movement speeds where the arms of cyclic workers moved faster, on average, than the non-cyclic workers. This difference in exposure could partially explain why the cyclic workers considered wearing sensors as more distracting.</p><p id="P58">Workers who reported higher levels of stress also reported higher burden ratings than those who reported lower levels of stress. Previous studies have indicated that shift workers that report high psychological demand and low job control are more likely to consider their jobs as physically demanding (<xref rid="R4" ref-type="bibr">Buja et al., 2013</xref>; <xref rid="R32" ref-type="bibr">Perrucci et al., 2007</xref>; <xref rid="R34" ref-type="bibr">Raeisi et al., 2014</xref>). It may be that workers who consider their job to be stressful are more likely to consider any additional activities they need to perform while working as burdensome, such as participating in wearing sensors at work. Further research is needed to investigate the relationship between stress experienced at work and the burden of completing additional tasks.</p><p id="P59">Another interesting finding of this study was the effect that several personal characteristics had on perceptions of discomfort, distraction, and burden. BMI, for instance, was observed to be associated with increases in perceived discomfort and distraction. One possible explanation for these results was that participants with a higher BMI may have had more difficulty finding a comfortable level of adjustment for the straps used to secure the devices around their upper arms. Circumference of the upper arms has been associated with discomfort as a result of pressure from the elastic securing the device that can lead to itchiness, skin irritation and rashes, and/or bruising (<xref rid="R27" ref-type="bibr">McNamara et al., 2016</xref>). Another explanation may be that overweight individuals may experience higher sweat levels than individuals with a healthy BMI (<xref rid="R28" ref-type="bibr">Nakayoshi et al., 2015</xref>). Wet straps may contribute to feelings of discomfort. Unfortunately, perspiration levels were not measured in this study. Future studies may include observation of perspiration and its potential negative effects on the perceived usability of wearable devices (<xref rid="R27" ref-type="bibr">Mcnamara et al., 2016</xref>).</p><p id="P60">Although the effect was small (beta=0.04), age was another significant predictor for sensor-related distraction and burden with younger workers reporting less distraction and burden than older workers. Seniors (aged 60 years or over) have been observed to have challenges adopting to technologies to which they are unaccustomed, such as wearable computer systems (<xref rid="R46" ref-type="bibr">Tedesco et al., 2017</xref>). Additional research, therefore, may focus on senior workers use of wearable computing systems in an effort to reduce potential distraction and burden to help improve adoption intention.</p><p id="P61">The relatively strong sex differences (relative to some other factors such as kinematic exposures) revealed in this study appear consistent with previous research findings suggesting that device preferences may differ based on sex and situation (<xref rid="R2" ref-type="bibr">Beeler et al., 2018</xref>; <xref rid="R14" ref-type="bibr">Huberty et al., 2015</xref>). The (dis)comfort associated with the use of wearable sensors may be related to the manner by which it is secured to an individual. Specifically, women may be more tolerant to some sensor designs such as sensor bands worn around the chest, as they may be perceived as more socially acceptable to wear, and they are more accustomed to wearing undergarments around the chest relative to men (<xref rid="R8" ref-type="bibr">Ertin et al., 2011</xref>). In our study, some participants asked researchers to disguise their sensors by securing them under articles of clothing. Future research may explore the effects of disguising sensors on ratings of sensor wear experience. Occupational safety and health professionals should consider sex differences when contemplating using wearable inertial sensors in the workplace.</p><p id="P62">The simplicity of the scales included in this study is an important limitation. (Dis)comfort, distraction, burden, and stress may each be considered complex, multifaceted terms. <xref rid="R20" ref-type="bibr">Knight and Baber (2005)</xref>, for example, suggested six dimensions (emotion, attachment, harm, perceived change, movement, and anxiety) that may affect a user&#x02019;s perception of comfort when using wearables. Given the broad scope of data collection in this study, it was not possible to have participants complete several multidimensional scales. Thus, our findings must be interpreted with caution (i.e., it is unknown which dimensions our ratings are attributed to or if they are consistent within and between participants). Future work may investigate the dimensions of each factor in more detail. It is also important to note that the recruitment procedures used in this study may have affected our results. Employees of the manufacturing facility needed to volunteer as candidates for potential inclusion in the study before they were randomly selected. Thus, participants may be considered early adopters of the technology and, therefore, more receptive to using them in the work environment relative to those that did not volunteer. Along these lines, one participant (of the total 36 that enrolled) withdrew from the study during the first shift of data collection. Although the participant did not provide an assessment of the (dis)comfort, distraction, and burden associated with using the sensors during that time, he was clearly uncomfortable, distracted, and/or burdened by the sensors and/or the experience of participating to a sufficient level to decide to withdraw from participating further.</p><p id="P63">As indicated in the methods, several participants did not wear one or multiple sensors for some work shifts due to personal health and/or safety concerns. For example, one participant chose not to wear the trunk sensor for several days after missing work due to an illness. Several participants did not wear the wrist and/or trunk sensor because they anticipated working near machinery. Although unfortunate, these scenarios were anticipated and are not expected to have greatly affected the general trend of our results. This study benefitted from a relatively large number of participants when considering the number of shifts collected per worker. However, the decision to not wear the sensors during some work shifts is very important to note. Similarly, undesirable ratings, particularly data points exceeding the upper quartile of the collected data as depicted in <xref rid="F1" ref-type="fig">Figure 1</xref>, indicate that discomfort, distraction, and burden can present as an important issue even if &#x0201c;typical&#x0201d; ratings are low. Stated reasons from participants for these high ratings were limited to those previously described (e.g., anticipation of working near machinery; loose sensor straps; irritating elastic connections; perceptions of socially unacceptable behavior). Ultimately, we suggest that occupational safety and health practitioners considering using wearable inertial sensors among manufacturing workers carefully factor this variability into the generally small effects that different personal (e.g., sex; age; BMI) and work (e.g., work categorization; perceptions of stress; exposure to kinematic risk factors) factors had in this study.</p></sec><sec id="S8"><label>5.</label><title>Conclusion</title><p id="P64">Wearable inertial sensors may be generally considered comfortable to wear and not distracting and/or burdensome for extended use (i.e., multiple full shifts) among manufacturing workers. Although spending more working time with the right (typically dominant) arm in non-neutral postures and increased worker BMIs contributed to statistically significantly higher average discomfort ratings, the reports of discomfort remained practically small. Similarly, cyclic work activities and higher BMIs were related to statistically significant, albeit small increases in distraction. Increases in age and perceived stress levels led to similar findings for burden ratings. Personal characteristics, work characteristics, and variability in perceptions of (dis)comfort, distraction, and burden should remain a forethought when considering using wearable inertial sensors to collect physical exposure information in the manufacturing sector.</p></sec></body><back><ack id="S9"><title>Acknowledgements</title><p id="P65">This study was supported by research funding from the Centers for Disease Control (CDC) / National Institute for Occupational Safety and Health (NIOSH; Grant # K01OH011183), with additional support from the Deep South Center for Occupational Health and Safety (CDC/NIOSH grant no: T42OH008436). The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the CDC/NIOSH.</p></ack><fn-group><fn id="FN1"><p id="P66">Competing Interests</p><p id="P67">The authors have declared that no competing interests exist.</p></fn></fn-group><ref-list><title>References</title><ref id="R1"><mixed-citation publication-type="confproc"><name><surname>Adams</surname><given-names>S</given-names></name>, <name><surname>Meekins</surname><given-names>R</given-names></name>, <name><surname>Beling</surname><given-names>PA</given-names></name>, <year>2017</year>. <source>An empirical evaluation of techniques for feature selection with cost</source>, <conf-name>2017 IEEE International Conference on Data Mining Workshops (ICDMW)</conf-name>. <publisher-name>IEEE</publisher-name>, pp. <fpage>834</fpage>&#x02013;<lpage>841</lpage>.</mixed-citation></ref><ref id="R2"><mixed-citation publication-type="journal"><name><surname>Beeler</surname><given-names>N</given-names></name>, <name><surname>Roos</surname><given-names>L</given-names></name>, <name><surname>Delves</surname><given-names>SK</given-names></name>, <name><surname>Veenstra</surname><given-names>BJ</given-names></name>, <name><surname>Friedl</surname><given-names>K</given-names></name>, <name><surname>Buller</surname><given-names>MJ</given-names></name>, <name><surname>Wyss</surname><given-names>T</given-names></name>, <year>2018</year>. <article-title>The wearing comfort and acceptability of ambulatory physical activity monitoring devices in soldiers</article-title>. <source>IISE Transactions on Occupational Ergonomics and Human Factors</source>
<volume>6</volume>, <fpage>1</fpage>&#x02013;<lpage>10</lpage>.</mixed-citation></ref><ref id="R3"><mixed-citation publication-type="journal"><name><surname>Bennett</surname><given-names>DA</given-names></name>, <year>2001</year>. <article-title>How can I deal with missing data in my study?</article-title>
<source>Australian and New Zealand journal of public health</source>
<volume>25</volume>, <fpage>464</fpage>&#x02013;<lpage>469</lpage>.<pub-id pub-id-type="pmid">11688629</pub-id>
</mixed-citation></ref><ref id="R4"><mixed-citation publication-type="journal"><name><surname>Buja</surname><given-names>A</given-names></name>, <name><surname>Zampieron</surname><given-names>A</given-names></name>, <name><surname>Mastrangelo</surname><given-names>G</given-names></name>, <name><surname>Petean</surname><given-names>M</given-names></name>, <name><surname>Vinelli</surname><given-names>A</given-names></name>, <name><surname>Cerne</surname><given-names>D</given-names></name>, <name><surname>Baldo</surname><given-names>V</given-names></name>, <year>2013</year>. <article-title>Strain and health implications of nurses&#x02019; shift work</article-title>. <source>International journal of occupational medicine and environmental health</source>
<volume>26</volume>, <fpage>511</fpage>&#x02013;<lpage>521</lpage>.<pub-id pub-id-type="pmid">24057261</pub-id>
</mixed-citation></ref><ref id="R5"><mixed-citation publication-type="confproc"><name><surname>Canina</surname><given-names>M</given-names></name>, <name><surname>Newman</surname><given-names>DJ</given-names></name>, <name><surname>Trotti</surname><given-names>GL</given-names></name>, <year>2006</year>. <source>Preliminary considerations for wearable sensors for astronauts in exploration scenarios</source>, <conf-name>2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors</conf-name>. <publisher-name>IEEE</publisher-name>, pp. <fpage>16</fpage>&#x02013;<lpage>19</lpage>.</mixed-citation></ref><ref id="R6"><mixed-citation publication-type="journal"><name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <year>2020</year>. <article-title>Measuring upper arm elevation using an inertial measurement unit: An exploration of sensor fusion algorithms and gyroscope models</article-title>. <source>Applied Ergonomics</source>
<volume>89</volume>, <fpage>103187</fpage>.<pub-id pub-id-type="pmid">32854821</pub-id>
</mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>David</surname><given-names>GC</given-names></name>, <year>2005</year>. <article-title>Ergonomic methods for assessing exposure to risk factors for work-related musculoskeletal disorders</article-title>. <source>Occup Med (Lond)</source>
<volume>55</volume>, <fpage>190</fpage>&#x02013;<lpage>199</lpage>.<pub-id pub-id-type="pmid">15857898</pub-id>
</mixed-citation></ref><ref id="R8"><mixed-citation publication-type="confproc"><name><surname>Ertin</surname><given-names>E</given-names></name>, <name><surname>Stohs</surname><given-names>N</given-names></name>, <name><surname>Kumar</surname><given-names>S</given-names></name>, <name><surname>Raij</surname><given-names>A</given-names></name>, <name><surname>Al&#x02019;Absi</surname><given-names>M</given-names></name>, <name><surname>Shah</surname><given-names>S</given-names></name>, <year>2011</year>. <source>AutoSense: unobtrusively wearable sensor suite for inferring the onset, causality, and consequences of stress in the field</source>, <conf-name>Proceedings of the 9th ACM Conference on Embedded Networked Sensor Systems</conf-name>, pp. <fpage>274</fpage>&#x02013;<lpage>287</lpage>.</mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Branch</surname><given-names>CA</given-names></name>, <name><surname>Merlino</surname><given-names>LA</given-names></name>, <year>2020</year>. <article-title>Biomechanical factors during common agricultural activities: Results of on-farm exposure assessments using direct measurement methods</article-title>. <source>Journal of Occupational and Environmental Hygiene</source>
<volume>17</volume>, <fpage>85</fpage>&#x02013;<lpage>96</lpage>.<pub-id pub-id-type="pmid">32069181</pub-id>
</mixed-citation></ref><ref id="R10"><mixed-citation publication-type="book"><name><surname>Frank</surname><given-names>E</given-names></name>, <name><surname>Hall</surname><given-names>M</given-names></name>, <name><surname>Holmes</surname><given-names>G</given-names></name>, <name><surname>Kirkby</surname><given-names>R</given-names></name>, <name><surname>Pfahringer</surname><given-names>B</given-names></name>, <name><surname>Witten</surname><given-names>IH</given-names></name>, <name><surname>Trigg</surname><given-names>L</given-names></name>, <year>2009</year>. <part-title>Weka-a machine learning workbench for data mining</part-title>, <source>Data mining and knowledge discovery handbook</source>. <publisher-name>Springer</publisher-name>, pp. <fpage>1269</fpage>&#x02013;<lpage>1277</lpage>.</mixed-citation></ref><ref id="R11"><mixed-citation publication-type="journal"><name><surname>Granzow</surname><given-names>RF</given-names></name>, <name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Smidt</surname><given-names>MF</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Huangfu</surname><given-names>R</given-names></name>, <year>2018</year>. <article-title>Characterizing exposure to physical risk factors among reforestation hand planters in the Southeastern United States</article-title>. <source>Applied ergonomics</source>
<volume>66</volume>, <fpage>1</fpage>&#x02013;<lpage>8</lpage>.<pub-id pub-id-type="pmid">28958420</pub-id>
</mixed-citation></ref><ref id="R12"><mixed-citation publication-type="confproc"><name><surname>Greco</surname><given-names>A</given-names></name>, <name><surname>Muoio</surname><given-names>M</given-names></name>, <name><surname>Lamberti</surname><given-names>M</given-names></name>, <name><surname>Gerbino</surname><given-names>S</given-names></name>, <name><surname>Caputo</surname><given-names>F</given-names></name>, <name><surname>Miraglia</surname><given-names>N</given-names></name>, <year>2019</year>. <source>Integrated wearable devices for evaluating the biomechanical overload in manufacturing</source>, <conf-name>2019 II Workshop on Metrology for Industry 4.0 and IoT (MetroInd4. 0&#x00026;IoT)</conf-name>. <publisher-name>IEEE</publisher-name>, pp. <fpage>93</fpage>&#x02013;<lpage>97</lpage>.</mixed-citation></ref><ref id="R13"><mixed-citation publication-type="journal"><name><surname>Hansson</surname><given-names>G-&#x000c5;</given-names></name>, <name><surname>Balogh</surname><given-names>I</given-names></name>, <name><surname>Ohlsson</surname><given-names>K</given-names></name>, <name><surname>Granqvist</surname><given-names>L</given-names></name>, <name><surname>Nordander</surname><given-names>C</given-names></name>, <name><surname>Arvidsson</surname><given-names>I</given-names></name>, <name><surname>&#x000c5;kesson</surname><given-names>I</given-names></name>, <name><surname>Unge</surname><given-names>J</given-names></name>, <name><surname>Rittner</surname><given-names>R</given-names></name>, <name><surname>Str&#x000f6;mberg</surname><given-names>U</given-names></name>, <name><surname>Skerfving</surname><given-names>S</given-names></name>, <year>2010</year>. <article-title>Physical workload in various types of work: Part II. Neck, shoulder and upper arm</article-title>. <source>International Journal of Industrial Ergonomics</source>
<volume>40</volume>, <fpage>267</fpage>&#x02013;<lpage>281</lpage>.</mixed-citation></ref><ref id="R14"><mixed-citation publication-type="journal"><name><surname>Huberty</surname><given-names>J</given-names></name>, <name><surname>Ehlers</surname><given-names>DK</given-names></name>, <name><surname>Kurka</surname><given-names>J</given-names></name>, <name><surname>Ainsworth</surname><given-names>B</given-names></name>, <name><surname>Buman</surname><given-names>M</given-names></name>, <year>2015</year>. <article-title>Feasibility of three wearable sensors for 24 hour monitoring in middle-aged women</article-title>. <source>BMC women&#x02019;s health</source>
<volume>15</volume>, <fpage>1</fpage>&#x02013;<lpage>9</lpage>.<pub-id pub-id-type="pmid">25608736</pub-id>
</mixed-citation></ref><ref id="R15"><mixed-citation publication-type="journal"><name><surname>Jacobs</surname><given-names>JV</given-names></name>, <name><surname>Hettinger</surname><given-names>LJ</given-names></name>, <name><surname>Huang</surname><given-names>Y-H</given-names></name>, <name><surname>Jeffries</surname><given-names>S</given-names></name>, <name><surname>Lesch</surname><given-names>MF</given-names></name>, <name><surname>Simmons</surname><given-names>LA</given-names></name>, <name><surname>Verma</surname><given-names>SK</given-names></name>, <name><surname>Willetts</surname><given-names>JL</given-names></name>, <year>2019</year>. <article-title>Employee acceptance of wearable technology in the workplace</article-title>. <source>Applied ergonomics</source>
<volume>78</volume>, <fpage>148</fpage>&#x02013;<lpage>156</lpage>.<pub-id pub-id-type="pmid">31046946</pub-id>
</mixed-citation></ref><ref id="R16"><mixed-citation publication-type="journal"><name><surname>Ji</surname><given-names>X</given-names></name>, <name><surname>Piovesan</surname><given-names>D</given-names></name>, <year>2020</year>. <article-title>Validation of inertial-magnetic wearable sensors for full-body motion tracking of automotive manufacturing operations</article-title>. <source>International Journal of Industrial Ergonomics</source>
<volume>79</volume>, 103005.</mixed-citation></ref><ref id="R17"><mixed-citation publication-type="journal"><name><surname>Kazmierczak</surname><given-names>K</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <name><surname>Forsman</surname><given-names>M</given-names></name>, <name><surname>Winkel</surname><given-names>J</given-names></name>, <year>2005</year>. <article-title>An integrated analysis of ergonomics and time consumption in Swedish &#x02018;craft-type&#x02019; car disassembly</article-title>. <source>Appl Ergon</source>
<volume>36</volume>, <fpage>263</fpage>&#x02013;<lpage>273</lpage>.<pub-id pub-id-type="pmid">15854569</pub-id>
</mixed-citation></ref><ref id="R18"><mixed-citation publication-type="journal"><name><surname>Kent</surname><given-names>P</given-names></name>, <name><surname>Laird</surname><given-names>R</given-names></name>, <name><surname>Haines</surname><given-names>T</given-names></name>, <year>2015</year>. <article-title>The effect of changing movement and posture using motion-sensor biofeedback, versus guidelines-based care, on the clinical outcomes of people with sub-acute or chronic low back pain-a multicentre, cluster-randomised, placebo-controlled, pilot trial</article-title>. <source>BMC musculoskeletal disorders</source>
<volume>16</volume>, <fpage>1</fpage>&#x02013;<lpage>19</lpage>.<pub-id pub-id-type="pmid">25637090</pub-id>
</mixed-citation></ref><ref id="R19"><mixed-citation publication-type="journal"><name><surname>Kersten</surname><given-names>JT</given-names></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <year>2019</year>. <article-title>Radio frequency identification to measure the duration of machine-paced assembly tasks: Agreement with self-reported task duration and application in variance components analyses of upper arm postures and movements recorded over multiple days</article-title>. <source>Applied ergonomics</source>
<volume>75</volume>, <fpage>74</fpage>&#x02013;<lpage>82</lpage>.<pub-id pub-id-type="pmid">30509539</pub-id>
</mixed-citation></ref><ref id="R20"><mixed-citation publication-type="journal"><name><surname>Knight</surname><given-names>JF</given-names></name>, <name><surname>Baber</surname><given-names>C</given-names></name>, <year>2005</year>. <article-title>A tool to assess the comfort of wearable computers</article-title>. <source>Human factors</source>
<volume>47</volume>, <fpage>77</fpage>&#x02013;<lpage>91</lpage>.<pub-id pub-id-type="pmid">15960088</pub-id>
</mixed-citation></ref><ref id="R21"><mixed-citation publication-type="confproc"><name><surname>le Feber</surname><given-names>M</given-names></name>, <name><surname>Jadoenathmisier</surname><given-names>T</given-names></name>, <name><surname>Goede</surname><given-names>H</given-names></name>, <name><surname>Kuijpers</surname><given-names>E</given-names></name>, <name><surname>Pronk</surname><given-names>A</given-names></name>, <year>2020</year>. <source>Ethics and Privacy Considerations Before Deploying Sensor Technologies for Exposure Assessment in the Workplace: Results of a Structured Discussion Amongst Dutch Stakeholders</source>. <conf-name>Annals of Work Exposures and Health</conf-name>.</mixed-citation></ref><ref id="R22"><mixed-citation publication-type="journal"><name><surname>Lee</surname><given-names>W</given-names></name>, <name><surname>Seto</surname><given-names>E</given-names></name>, <name><surname>Lin</surname><given-names>K-Y</given-names></name>, <name><surname>Migliaccio</surname><given-names>GC</given-names></name>, <year>2017</year>. <article-title>An evaluation of wearable sensors and their placements for analyzing construction worker&#x02019;s trunk posture in laboratory conditions</article-title>. <source>Applied ergonomics</source>
<volume>65</volume>, <fpage>424</fpage>&#x02013;<lpage>436</lpage>.<pub-id pub-id-type="pmid">28420483</pub-id>
</mixed-citation></ref><ref id="R23"><mixed-citation publication-type="confproc"><name><surname>Leng</surname><given-names>LB</given-names></name>, <name><surname>Giin</surname><given-names>LB</given-names></name>, <name><surname>Chung</surname><given-names>W-Y</given-names></name>, <year>2015</year>. <source>Wearable driver drowsiness detection system based on biomedical and motion sensors</source>, <conf-name>2015 IEEE SENSORS</conf-name>. <publisher-name>IEEE</publisher-name>, pp. <fpage>1</fpage>&#x02013;<lpage>4</lpage>.</mixed-citation></ref><ref id="R24"><mixed-citation publication-type="confproc"><name><surname>Liu</surname><given-names>L</given-names></name>, <name><surname>Karatas</surname><given-names>C</given-names></name>, <name><surname>Li</surname><given-names>H</given-names></name>, <name><surname>Tan</surname><given-names>S</given-names></name>, <name><surname>Gruteser</surname><given-names>M</given-names></name>, <name><surname>Yang</surname><given-names>J</given-names></name>, <name><surname>Chen</surname><given-names>Y</given-names></name>, <name><surname>Martin</surname><given-names>RP</given-names></name>, <year>2015</year>. <source>Toward detection of unsafe driving with wearables</source>, <conf-name>Proceedings of the 2015 workshop on Wearable Systems and Applications</conf-name>, pp. <fpage>27</fpage>&#x02013;<lpage>32</lpage>.</mixed-citation></ref><ref id="R25"><mixed-citation publication-type="journal"><name><surname>Maman</surname><given-names>ZS</given-names></name>, <name><surname>Yazdi</surname><given-names>MAA</given-names></name>, <name><surname>Cavuoto</surname><given-names>LA</given-names></name>, <name><surname>Megahed</surname><given-names>FM</given-names></name>, <year>2017</year>. <article-title>A data-driven approach to modeling physical fatigue in the workplace using wearable sensors</article-title>. <source>Applied ergonomics</source>
<volume>65</volume>, <fpage>515</fpage>&#x02013;<lpage>529</lpage>.<pub-id pub-id-type="pmid">28259238</pub-id>
</mixed-citation></ref><ref id="R26"><mixed-citation publication-type="confproc"><name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <name><surname>Burdorf</surname><given-names>A</given-names></name>, <name><surname>Holtermann</surname><given-names>A</given-names></name>, <name><surname>J&#x000e4;rvholm</surname><given-names>B</given-names></name>, <name><surname>Knardahl</surname><given-names>S</given-names></name>, <name><surname>Proper</surname><given-names>K</given-names></name>, <name><surname>Punnett</surname><given-names>L</given-names></name>, <name><surname>Straker</surname><given-names>L</given-names></name>, <name><surname>S&#x000f8;gaard</surname><given-names>K</given-names></name>, <year>2015</year>. <source>Occupational epidemiology: six guiding principles for future studies of physical work load and its effects on health and performance</source>, <conf-name>Proceedings 19th Triennial Congress of the IEA</conf-name>, p. <fpage>14</fpage>.</mixed-citation></ref><ref id="R27"><mixed-citation publication-type="journal"><name><surname>McNamara</surname><given-names>RJ</given-names></name>, <name><surname>Tsai</surname><given-names>LLY</given-names></name>, <name><surname>Wootton</surname><given-names>SL</given-names></name>, <name><surname>Ng</surname><given-names>LC</given-names></name>, <name><surname>Dale</surname><given-names>MT</given-names></name>, <name><surname>McKeough</surname><given-names>ZJ</given-names></name>, <name><surname>Alison</surname><given-names>JA</given-names></name>, <year>2016</year>. <article-title>Measurement of daily physical activity using the SenseWear Armband: Compliance, comfort, adverse side effects and usability</article-title>. <source>Chronic respiratory disease</source>
<volume>13</volume>, <fpage>144</fpage>&#x02013;<lpage>154</lpage>.<pub-id pub-id-type="pmid">26879695</pub-id>
</mixed-citation></ref><ref id="R28"><mixed-citation publication-type="journal"><name><surname>Nakayoshi</surname><given-names>M</given-names></name>, <name><surname>Kanda</surname><given-names>M</given-names></name>, <name><surname>Shi</surname><given-names>R</given-names></name>, <name><surname>de Dear</surname><given-names>R</given-names></name>, <year>2015</year>. <article-title>Outdoor thermal physiology along human pathways: a study using a wearable measurement system</article-title>. <source>International journal of biometeorology</source>
<volume>59</volume>, <fpage>503</fpage>&#x02013;<lpage>515</lpage>.<pub-id pub-id-type="pmid">25011423</pub-id>
</mixed-citation></ref><ref id="R29"><mixed-citation publication-type="journal"><name><surname>Onan</surname><given-names>A</given-names></name>, <name><surname>Koruko&#x0011f;lu</surname><given-names>S</given-names></name>, <year>2017</year>. <article-title>A feature selection model based on genetic rank aggregation for text sentiment classification</article-title>. <source>Journal of Information Science</source>
<volume>43</volume>, <fpage>25</fpage>&#x02013;<lpage>38</lpage>.</mixed-citation></ref><ref id="R30"><mixed-citation publication-type="book"><collab>OSHA, O.S.a.H.A.</collab>, <year>2014</year>. <source>1218-AB58 &#x02013; 2014. Prevention of Work-related Musculoskeletal Disorders</source>
<publisher-name>Occupational Safety and Health Administration</publisher-name>, <publisher-loc>Washington, D.C.</publisher-loc></mixed-citation></ref><ref id="R31"><mixed-citation publication-type="journal"><name><surname>Paulsen</surname><given-names>R</given-names></name>, <name><surname>Schwatka</surname><given-names>N</given-names></name>, <name><surname>Gober</surname><given-names>J</given-names></name>, <name><surname>Gilkey</surname><given-names>D</given-names></name>, <name><surname>Anton</surname><given-names>D</given-names></name>, <name><surname>Gerr</surname><given-names>F</given-names></name>, <name><surname>Rosecrance</surname><given-names>J</given-names></name>, <year>2014</year>. <article-title>Inter-rater reliability of cyclic and non-cyclic task assessment using the hand activity level in appliance manufacturing</article-title>. <source>International journal of industrial ergonomics</source>
<volume>44</volume>, <fpage>32</fpage>&#x02013;<lpage>38</lpage>.<pub-id pub-id-type="pmid">26120222</pub-id>
</mixed-citation></ref><ref id="R32"><mixed-citation publication-type="journal"><name><surname>Perrucci</surname><given-names>R</given-names></name>, <name><surname>MacDermid</surname><given-names>S</given-names></name>, <name><surname>King</surname><given-names>E</given-names></name>, <name><surname>Tang</surname><given-names>C-Y</given-names></name>, <name><surname>Brimeyer</surname><given-names>T</given-names></name>, <name><surname>Ramadoss</surname><given-names>K</given-names></name>, <name><surname>Kiser</surname><given-names>SJ</given-names></name>, <name><surname>Swanberg</surname><given-names>J</given-names></name>, <year>2007</year>. <article-title>The significance of shift work: Current status and future directions</article-title>. <source>Journal of Family and Economic Issues</source>
<volume>28</volume>, <fpage>600</fpage>&#x02013;<lpage>617</lpage>.</mixed-citation></ref><ref id="R33"><mixed-citation publication-type="journal"><name><surname>Proger</surname><given-names>S</given-names></name>, <name><surname>Dexter</surname><given-names>L</given-names></name>, <year>1934</year>. <article-title>The Continuous Measurement of the Velocity of Venous Blood Flow in the Arm during Exercise and Change of Posture</article-title>. <source>American Journal of Physiology-Legacy Content</source>
<volume>109</volume>, <fpage>688</fpage>&#x02013;<lpage>692</lpage>.</mixed-citation></ref><ref id="R34"><mixed-citation publication-type="journal"><name><surname>Raeisi</surname><given-names>S</given-names></name>, <name><surname>Namvar</surname><given-names>M</given-names></name>, <name><surname>Golabadi</surname><given-names>M</given-names></name>, <name><surname>Attarchi</surname><given-names>M</given-names></name>, <year>2014</year>. <article-title>Combined effects of physical demands and shift working on low back disorders among nursing personnel</article-title>. <source>International journal of occupational safety and ergonomics</source>
<volume>20</volume>, <fpage>159</fpage>&#x02013;<lpage>166</lpage>.<pub-id pub-id-type="pmid">24629877</pub-id>
</mixed-citation></ref><ref id="R35"><mixed-citation publication-type="confproc"><name><surname>Reid</surname><given-names>CR</given-names></name>, <name><surname>Schall</surname><given-names>MC</given-names></name>, <name><surname>Amick</surname><given-names>RZ</given-names></name>, <name><surname>Schiffman</surname><given-names>JM</given-names></name>, <name><surname>Lu</surname><given-names>M-L</given-names></name>, <name><surname>Smets</surname><given-names>M</given-names></name>, <name><surname>Moses</surname><given-names>HR</given-names></name>, <name><surname>Porto</surname><given-names>R</given-names></name>, <year>2017</year>. <source>Wearable Technologies: How Will We Overcome Barriers to Enhance Worker Performance, Health, And Safety?</source>, <conf-name>Proceedings of the Human Factors and Ergonomics Society Annual Meeting</conf-name>. <publisher-name>SAGE Publications</publisher-name>
<conf-loc>Sage CA: Los Angeles, CA</conf-loc>, pp. <fpage>1026</fpage>&#x02013;<lpage>1030</lpage>.</mixed-citation></ref><ref id="R36"><mixed-citation publication-type="journal"><name><surname>Rossetti</surname><given-names>Y</given-names></name>, <name><surname>Meckler</surname><given-names>C</given-names></name>, <name><surname>Prablanc</surname><given-names>C</given-names></name>, <year>1994</year>. <article-title>Is there an optimal arm posture? Deterioration of finger localization precision and comfort sensation in extreme arm-joint postures</article-title>. <source>Experimental Brain Research</source>
<volume>99</volume>, <fpage>131</fpage>&#x02013;<lpage>136</lpage>.<pub-id pub-id-type="pmid">7925786</pub-id>
</mixed-citation></ref><ref id="R37"><mixed-citation publication-type="journal"><name><surname>Royston</surname><given-names>P</given-names></name>, <name><surname>White</surname><given-names>IR</given-names></name>, <year>2011</year>. <article-title>Multiple imputation by chained equations (MICE): implementation in Stata</article-title>. <source>J Stat Softw</source>
<volume>45</volume>, <fpage>1</fpage>&#x02013;<lpage>20</lpage>.</mixed-citation></ref><ref id="R38"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <year>2016a</year>. <article-title>Evaluation of four sensor locations for physical activity assessment</article-title>. <source>Applied ergonomics</source>
<volume>53</volume>, <fpage>103</fpage>&#x02013;<lpage>109</lpage>.<pub-id pub-id-type="pmid">26674410</pub-id>
</mixed-citation></ref><ref id="R39"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <year>2016b</year>. <article-title>Working postures and physical activity among registered nurses</article-title>. <source>Applied ergonomics</source>
<volume>54</volume>, <fpage>243</fpage>&#x02013;<lpage>250</lpage>.<pub-id pub-id-type="pmid">26851483</pub-id>
</mixed-citation></ref><ref id="R40"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Kitzmann</surname><given-names>AS</given-names></name>, <year>2014</year>. <article-title>A Comparison of Examination Equipment Used During Common Clinical Ophthalmologic Tasks</article-title>. <source>IIE Transactions on Occupational Ergonomics and Human Factors</source>
<volume>2</volume>, <fpage>105</fpage>&#x02013;<lpage>117</lpage>.<pub-id pub-id-type="pmid">37180554</pub-id>
</mixed-citation></ref><ref id="R41"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Oyama</surname><given-names>S</given-names></name>, <name><surname>Douphrate</surname><given-names>DI</given-names></name>, <year>2016c</year>. <article-title>Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies</article-title>. <source>Ergonomics</source>
<volume>59</volume>, <fpage>591</fpage>&#x02013;<lpage>602</lpage>.<pub-id pub-id-type="pmid">26256753</pub-id>
</mixed-citation></ref><ref id="R42"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Sesek</surname><given-names>RF</given-names></name>, <name><surname>Cavuoto</surname><given-names>LA</given-names></name>, <year>2018</year>. <article-title>Barriers to the Adoption of Wearable Sensors in the Workplace: A Survey of Occupational Safety and Health Professionals</article-title>. <source>Human factors</source>
<volume>60</volume>, <fpage>351</fpage>&#x02013;<lpage>362</lpage>.<pub-id pub-id-type="pmid">29320232</pub-id>
</mixed-citation></ref><ref id="R43"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Zhang</surname><given-names>X</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Gallagher</surname><given-names>S</given-names></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <year>2021</year>. <article-title>Comparing upper arm and trunk kinematics between manufacturing workers performing predominantly cyclic and non-cyclic work tasks</article-title>. <source>Applied Ergonomics</source>
<volume>93</volume>, 103356.</mixed-citation></ref><ref id="R44"><mixed-citation publication-type="journal"><name><surname>Spielholz</surname><given-names>P</given-names></name>, <name><surname>Silverstein</surname><given-names>B</given-names></name>, <name><surname>Morgan</surname><given-names>M</given-names></name>, <name><surname>Checkoway</surname><given-names>H</given-names></name>, <name><surname>Kaufman</surname><given-names>J</given-names></name>, <year>2001</year>. <article-title>Comparison of self-report, video observation and direct measurement methods for upper extremity musculoskeletal disorder physical risk factors</article-title>. <source>Ergonomics</source>
<volume>44</volume>, <fpage>588</fpage>&#x02013;<lpage>613</lpage>.<pub-id pub-id-type="pmid">11373023</pub-id>
</mixed-citation></ref><ref id="R45"><mixed-citation publication-type="journal"><name><surname>Tao</surname><given-names>W</given-names></name>, <name><surname>Lai</surname><given-names>Z-H</given-names></name>, <name><surname>Leu</surname><given-names>MC</given-names></name>, <name><surname>Yin</surname><given-names>Z</given-names></name>, <year>2018</year>. <article-title>Worker activity recognition in smart manufacturing using IMU and sEMG signals with convolutional neural networks</article-title>. <source>Procedia Manufacturing</source>
<volume>26</volume>, <fpage>1159</fpage>&#x02013;<lpage>1166</lpage>.</mixed-citation></ref><ref id="R46"><mixed-citation publication-type="journal"><name><surname>Tedesco</surname><given-names>S</given-names></name>, <name><surname>Barton</surname><given-names>J</given-names></name>, <name><surname>O&#x02019;Flynn</surname><given-names>B</given-names></name>, <year>2017</year>. <article-title>A review of activity trackers for senior citizens: Research perspectives, commercial landscape and the role of the insurance industry</article-title>. <source>Sensors</source>
<volume>17</volume>, <fpage>1277</fpage>.<pub-id pub-id-type="pmid">28587188</pub-id>
</mixed-citation></ref><ref id="R47"><mixed-citation publication-type="journal"><name><surname>Teschke</surname><given-names>K</given-names></name>, <name><surname>Trask</surname><given-names>C</given-names></name>, <name><surname>Johnson</surname><given-names>P</given-names></name>, <name><surname>Chow</surname><given-names>Y</given-names></name>, <name><surname>Village</surname><given-names>J</given-names></name>, <name><surname>Koehoorn</surname><given-names>M</given-names></name>, <year>2009</year>. <article-title>Measuring posture for epidemiology: comparing inclinometry, observations and self-reports</article-title>. <source>Ergonomics</source>
<volume>52</volume>, <fpage>1067</fpage>&#x02013;<lpage>1078</lpage>.<pub-id pub-id-type="pmid">19787510</pub-id>
</mixed-citation></ref><ref id="R48"><mixed-citation publication-type="journal"><name><surname>Thiese</surname><given-names>M</given-names></name>, <year>2014</year>. <article-title>Important differences in accelerometer cut points for quantifying physical activity in a nested occupational cohort</article-title>. <source>J Exerc Sports Orthop</source>
<volume>1</volume>, <fpage>12</fpage>.</mixed-citation></ref><ref id="R49"><mixed-citation publication-type="journal"><name><surname>Urbanowicz</surname><given-names>RJ</given-names></name>, <name><surname>Meeker</surname><given-names>M</given-names></name>, <name><surname>La Cava</surname><given-names>W</given-names></name>, <name><surname>Olson</surname><given-names>RS</given-names></name>, <name><surname>Moore</surname><given-names>JH</given-names></name>, <year>2018</year>. <article-title>Relief-based feature selection: Introduction and review</article-title>. <source>Journal of biomedical informatics</source>
<volume>85</volume>, <fpage>189</fpage>&#x02013;<lpage>203</lpage>.<pub-id pub-id-type="pmid">30031057</pub-id>
</mixed-citation></ref><ref id="R50"><mixed-citation publication-type="book"><collab>USBLS, U.S.B.o.L.S.</collab>, <year>2020a</year>. <source>Employer-Reported Workplace Injuries and Illnesses (Annual) News Release -- 2019 (USDL-20&#x02013;2030)</source>, in: <name><surname>Labor</surname><given-names>D.o.</given-names></name> (Ed.), <publisher-loc>Washington, D.C.</publisher-loc></mixed-citation></ref><ref id="R51"><mixed-citation publication-type="book"><collab>USBLS, U.S.B.o.L.S.</collab>, <year>2020b</year>. <source>Occupational injuries and illnesses resulting in musculoskeletal disorders (MSDs)</source>, in: <name><surname>Labor</surname><given-names>D.o.</given-names></name> (Ed.), <publisher-loc>Washington, D.C.</publisher-loc></mixed-citation></ref><ref id="R52"><mixed-citation publication-type="journal"><name><surname>Wahlstr&#x000f6;m</surname><given-names>J</given-names></name>, <name><surname>Bergsten</surname><given-names>E</given-names></name>, <name><surname>Trask</surname><given-names>C</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <name><surname>Jackson</surname><given-names>J</given-names></name>, <name><surname>Forsman</surname><given-names>M</given-names></name>, <year>2016</year>. <article-title>Full-shift trunk and upper arm postures and movements among aircraft baggage handlers</article-title>. <source>Annals of Occupational Hygiene</source>
<volume>60</volume>, <fpage>977</fpage>&#x02013;<lpage>990</lpage>.<pub-id pub-id-type="pmid">27417186</pub-id>
</mixed-citation></ref><ref id="R53"><mixed-citation publication-type="journal"><name><surname>Wahlstr&#x000f6;m</surname><given-names>J</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <name><surname>Liv</surname><given-names>P</given-names></name>, <name><surname>Hedlund</surname><given-names>P</given-names></name>, <name><surname>Ahlgren</surname><given-names>C</given-names></name>, <name><surname>Forsman</surname><given-names>M</given-names></name>, <year>2010</year>. <article-title>Upper arm postures and movements in female hairdressers across four full working days</article-title>. <source>Ann Occup Hyg</source>
<volume>54</volume>, <fpage>584</fpage>&#x02013;<lpage>594</lpage>.<pub-id pub-id-type="pmid">20385661</pub-id>
</mixed-citation></ref><ref id="R54"><mixed-citation publication-type="journal"><name><surname>Winkel</surname><given-names>J</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <year>1994</year>. <article-title>Assessment of physical work load in epidemiologic studies: concepts, issues and operational considerations</article-title>. <source>Ergonomics</source>
<volume>37</volume>, <fpage>979</fpage>&#x02013;<lpage>988</lpage>.<pub-id pub-id-type="pmid">8026455</pub-id>
</mixed-citation></ref><ref id="R55"><mixed-citation publication-type="confproc"><name><surname>Zhang</surname><given-names>X</given-names></name>, <name><surname>Hani</surname><given-names>DB</given-names></name>, <name><surname>Gallagher</surname><given-names>S</given-names></name>, <name><surname>Schall</surname><given-names>M</given-names></name>, <year>2019</year>. <source>Manufacturing Worker Perceptions of Wearing Ambulatory Inertial Sensors in the Workplace: An Exploratory Cluster Analysis</source>, <conf-name>Annual Conference of the International Society for Occupational Ergonomics and Safety</conf-name>, <publisher-loc>New Orleans, LA</publisher-loc>.</mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Figure 1.</label><caption><p id="P68">Boxplots of sensor ratings over 15 full work shifts. A rating of 0 indicated no discomfort, distraction, or burden, while a rating of 10 indicated maximum discomfort, distraction, or burden for that work shift. The length of each box represents the interquartile range (the distance between the 25<sup>th</sup> and 75<sup>th</sup> percentiles). The diamond within each box indicates the group mean. The horizontal line in each box indicates the group median. The vertical lines (i.e., whiskers) issuing from each box extend to the most extreme point that is less than or equal to 1.5 times the interquartile range. &#x0201c;Outlier&#x0201d; or extreme values within a group are plotted as circles beyond the whiskers of the each box. The connected line across the 15 boxplots indicates the trend of the group mean from shift to shift.</p></caption><graphic xlink:href="nihms-1970133-f0001" position="float"/></fig><table-wrap position="float" id="T1"><label>Table 1:</label><caption><p id="P69">Feature Selection Results</p></caption><table frame="box" rules="all"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th colspan="3" align="center" valign="middle" rowspan="1">Discomfort</th><th colspan="3" align="center" valign="middle" rowspan="1">Distraction</th><th colspan="3" align="center" valign="middle" rowspan="1">Burden</th></tr><tr><th align="center" valign="middle" rowspan="1" colspan="1">Attribute</th><th align="center" valign="middle" rowspan="1" colspan="1">Avg. Merit</th><th align="center" valign="middle" rowspan="1" colspan="1">Avg. Rank</th><th align="center" valign="middle" rowspan="1" colspan="1">Attribute</th><th align="center" valign="middle" rowspan="1" colspan="1">Avg. Merit</th><th align="center" valign="middle" rowspan="1" colspan="1">Avg. Rank</th><th align="center" valign="middle" rowspan="1" colspan="1">Attribute</th><th align="center" valign="middle" rowspan="1" colspan="1">Avg. Merit</th><th align="center" valign="middle" rowspan="1" colspan="1">Avg. Rank</th></tr></thead><tbody><tr><td align="center" valign="middle" rowspan="1" colspan="1">Stress</td><td align="center" valign="middle" rowspan="1" colspan="1">0.061</td><td align="center" valign="middle" rowspan="1" colspan="1">1</td><td align="center" valign="middle" rowspan="1" colspan="1">Stress</td><td align="center" valign="middle" rowspan="1" colspan="1">0.044</td><td align="center" valign="middle" rowspan="1" colspan="1">1</td><td align="center" valign="middle" rowspan="1" colspan="1">Stress</td><td align="center" valign="middle" rowspan="1" colspan="1">0.070</td><td align="center" valign="middle" rowspan="1" colspan="1">1</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Age</td><td align="center" valign="middle" rowspan="1" colspan="1">0.038</td><td align="center" valign="middle" rowspan="1" colspan="1">2</td><td align="center" valign="middle" rowspan="1" colspan="1">Age</td><td align="center" valign="middle" rowspan="1" colspan="1">0.032</td><td align="center" valign="middle" rowspan="1" colspan="1">2</td><td align="center" valign="middle" rowspan="1" colspan="1">Age</td><td align="center" valign="middle" rowspan="1" colspan="1">0.034</td><td align="center" valign="middle" rowspan="1" colspan="1">2</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">BMI</td><td align="center" valign="middle" rowspan="1" colspan="1">0.028</td><td align="center" valign="middle" rowspan="1" colspan="1">3</td><td align="center" valign="middle" rowspan="1" colspan="1">BMI</td><td align="center" valign="middle" rowspan="1" colspan="1">0.026</td><td align="center" valign="middle" rowspan="1" colspan="1">3</td><td align="center" valign="middle" rowspan="1" colspan="1">BMI</td><td align="center" valign="middle" rowspan="1" colspan="1">0.027</td><td align="center" valign="middle" rowspan="1" colspan="1">3</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">LA60+</td><td align="center" valign="middle" rowspan="1" colspan="1">0.023</td><td align="center" valign="middle" rowspan="1" colspan="1">4</td><td align="center" valign="middle" rowspan="1" colspan="1">LA60+</td><td align="center" valign="middle" rowspan="1" colspan="1">0.017</td><td align="center" valign="middle" rowspan="1" colspan="1">4</td><td align="center" valign="middle" rowspan="1" colspan="1">LA60+</td><td align="center" valign="middle" rowspan="1" colspan="1">0.019</td><td align="center" valign="middle" rowspan="1" colspan="1">4</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">RA60+</td><td align="center" valign="middle" rowspan="1" colspan="1">0.013</td><td align="center" valign="middle" rowspan="1" colspan="1">5.1</td><td align="center" valign="middle" rowspan="1" colspan="1">FE90P</td><td align="center" valign="middle" rowspan="1" colspan="1">0.008</td><td align="center" valign="middle" rowspan="1" colspan="1">5.8</td><td align="center" valign="middle" rowspan="1" colspan="1">Work Category</td><td align="center" valign="middle" rowspan="1" colspan="1">0.010</td><td align="center" valign="middle" rowspan="1" colspan="1">6.1</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">RANLS</td><td align="center" valign="middle" rowspan="1" colspan="1">0.007</td><td align="center" valign="middle" rowspan="1" colspan="1">7.7</td><td align="center" valign="middle" rowspan="1" colspan="1">Work Category</td><td align="center" valign="middle" rowspan="1" colspan="1">0.007</td><td align="center" valign="middle" rowspan="1" colspan="1">6.9</td><td align="center" valign="middle" rowspan="1" colspan="1">RA60+</td><td align="center" valign="middle" rowspan="1" colspan="1">0.007</td><td align="center" valign="middle" rowspan="1" colspan="1">6.8</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Work Category</td><td align="center" valign="middle" rowspan="1" colspan="1">0.007</td><td align="center" valign="middle" rowspan="1" colspan="1">8</td><td align="center" valign="middle" rowspan="1" colspan="1">RA60+</td><td align="center" valign="middle" rowspan="1" colspan="1">0.006</td><td align="center" valign="middle" rowspan="1" colspan="1">7.2</td><td align="center" valign="middle" rowspan="1" colspan="1">FE90P</td><td align="center" valign="middle" rowspan="1" colspan="1">0.006</td><td align="center" valign="middle" rowspan="1" colspan="1">8.7</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Sex</td><td align="center" valign="middle" rowspan="1" colspan="1">0.004</td><td align="center" valign="middle" rowspan="1" colspan="1">11.1</td><td align="center" valign="middle" rowspan="1" colspan="1">Sex</td><td align="center" valign="middle" rowspan="1" colspan="1">0.006</td><td align="center" valign="middle" rowspan="1" colspan="1">7.6</td><td align="center" valign="middle" rowspan="1" colspan="1">RANLS</td><td align="center" valign="middle" rowspan="1" colspan="1">0.004</td><td align="center" valign="middle" rowspan="1" colspan="1">9.8</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">FE90P</td><td align="center" valign="middle" rowspan="1" colspan="1">0.002</td><td align="center" valign="middle" rowspan="1" colspan="1">14.5</td><td align="center" valign="middle" rowspan="1" colspan="1">RANLS</td><td align="center" valign="middle" rowspan="1" colspan="1">0.004</td><td align="center" valign="middle" rowspan="1" colspan="1">10</td><td align="center" valign="middle" rowspan="1" colspan="1">Sex</td><td align="center" valign="middle" rowspan="1" colspan="1">0.003</td><td align="center" valign="middle" rowspan="1" colspan="1">11.2</td></tr></tbody></table><table-wrap-foot><fn id="TFN1"><p id="P70">Avg. Merit = A measure of the importance and usefulness of a selected feature in the statistical model.</p></fn><fn id="TFN2"><p id="P71">Avg. Rank = The order of importance or usefulness assigned based on the merit scoring function.</p></fn><fn id="TFN3"><p id="P72">LA60+ = Percentage of time with the left arm elevated &#x02265; 60&#x000b0;</p></fn><fn id="TFN4"><p id="P73">RA60+ = Percentage of time with the right arm elevated &#x02265; 60&#x000b0;</p></fn><fn id="TFN5"><p id="P74">RANLS = Percentage of time with the right arm elevated &#x0003c; 20&#x000b0; and moving &#x0003c; 5&#x000b0;/s</p></fn><fn id="TFN6"><p id="P75">FE90P = The 90th percentile of trunk flexion/extension</p></fn></table-wrap-foot></table-wrap><table-wrap position="float" id="T2"><label>Table 2:</label><caption><p id="P76">Participant information by work group and sex</p></caption><table frame="box" rules="all"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th rowspan="1" colspan="1"/><th colspan="3" align="center" valign="middle" rowspan="1">CYCLIC</th><th colspan="3" align="center" valign="middle" rowspan="1">NON-CYCLIC</th></tr><tr><th rowspan="1" colspan="1"/><th align="center" valign="middle" rowspan="1" colspan="1">N</th><th align="center" valign="middle" rowspan="1" colspan="1">Mean</th><th align="center" valign="middle" rowspan="1" colspan="1">SD</th><th align="center" valign="middle" rowspan="1" colspan="1">N</th><th align="center" valign="middle" rowspan="1" colspan="1">Mean</th><th align="center" valign="middle" rowspan="1" colspan="1">SD</th></tr></thead><tbody><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<italic toggle="yes">
<bold>Male</bold>
</italic>
</td><td align="center" valign="middle" rowspan="1" colspan="1">6</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">11<xref rid="TFN7" ref-type="table-fn">*</xref></td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Age (years)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">29.0</td><td align="center" valign="middle" rowspan="1" colspan="1">6.9</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">40.2</td><td align="center" valign="middle" rowspan="1" colspan="1">12.6</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Height (cm)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">183.7</td><td align="center" valign="middle" rowspan="1" colspan="1">6.9</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">179.4</td><td align="center" valign="middle" rowspan="1" colspan="1">5.2</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">BMI (kg/m<sup>2</sup>)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">32.1</td><td align="center" valign="middle" rowspan="1" colspan="1">10.7</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">29.6</td><td align="center" valign="middle" rowspan="1" colspan="1">4.2</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Shift duration (hours)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">8.3</td><td align="center" valign="middle" rowspan="1" colspan="1">0.5</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">8.1</td><td align="center" valign="middle" rowspan="1" colspan="1">0.7</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<italic toggle="yes">
<bold>Female</bold>
</italic>
</td><td align="center" valign="middle" rowspan="1" colspan="1">9</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">5</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Age (years)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">47.0</td><td align="center" valign="middle" rowspan="1" colspan="1">10.0</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">47.6</td><td align="center" valign="middle" rowspan="1" colspan="1">12.4</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Height (cm)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">164.5</td><td align="center" valign="middle" rowspan="1" colspan="1">5.9</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">163.6</td><td align="center" valign="middle" rowspan="1" colspan="1">6.9</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">BMI (kg/m<sup>2</sup>)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">31.1</td><td align="center" valign="middle" rowspan="1" colspan="1">6.3</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">33.3</td><td align="center" valign="middle" rowspan="1" colspan="1">7.8</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">Shift duration (hours)</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">8.5</td><td align="center" valign="middle" rowspan="1" colspan="1">1.2</td><td align="center" valign="middle" rowspan="1" colspan="1"/><td align="center" valign="middle" rowspan="1" colspan="1">9.0</td><td align="center" valign="middle" rowspan="1" colspan="1">1.0</td></tr></tbody></table><table-wrap-foot><fn id="TFN7"><label>*</label><p id="P77">Only one male participant in the non-cyclic group was left hand dominant.</p></fn></table-wrap-foot></table-wrap><table-wrap position="float" id="T3" orientation="landscape"><label>Table 3.</label><caption><p id="P78">Results of the Generalized Linear Models</p></caption><table frame="box" rules="all"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th rowspan="1" colspan="1"/><th colspan="5" align="center" valign="middle" rowspan="1">Discomfort</th><th colspan="5" align="center" valign="middle" rowspan="1">Distraction</th><th colspan="5" align="center" valign="middle" rowspan="1">Burden</th></tr><tr><th align="center" valign="middle" rowspan="1" colspan="1">Effect</th><th align="center" valign="middle" rowspan="1" colspan="1">Estimate</th><th align="center" valign="middle" rowspan="1" colspan="1">Std. Error</th><th align="center" valign="middle" rowspan="1" colspan="1">p</th><th align="center" valign="middle" rowspan="1" colspan="1">95% CI Lower</th><th align="center" valign="middle" rowspan="1" colspan="1">95% CI Upper</th><th align="center" valign="middle" rowspan="1" colspan="1">Estimate</th><th align="center" valign="middle" rowspan="1" colspan="1">Std. Error</th><th align="center" valign="middle" rowspan="1" colspan="1">p</th><th align="center" valign="middle" rowspan="1" colspan="1">95% CI Lower</th><th align="center" valign="middle" rowspan="1" colspan="1">95% CI Upper</th><th align="center" valign="middle" rowspan="1" colspan="1">Estimate</th><th align="center" valign="middle" rowspan="1" colspan="1">Std. Error</th><th align="center" valign="middle" rowspan="1" colspan="1">p</th><th align="center" valign="middle" rowspan="1" colspan="1">95% CI Lower</th><th align="center" valign="middle" rowspan="1" colspan="1">95% CI Upper</th></tr></thead><tbody><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Intercept</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;1.04</td><td align="center" valign="middle" rowspan="1" colspan="1">0.68</td><td align="center" valign="middle" rowspan="1" colspan="1">0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;2.44</td><td align="center" valign="middle" rowspan="1" colspan="1">0.37</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.27</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.31</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.81</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">0.22</td><td align="center" valign="middle" rowspan="1" colspan="1">0.52</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.59</td><td align="center" valign="middle" rowspan="1" colspan="1">0.31</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Stress</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">0.41</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">0.07</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.16</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.05</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.03</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Non-Cyclic</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.24</td><td align="center" valign="middle" rowspan="1" colspan="1">0.94</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.51</td><td align="center" valign="middle" rowspan="1" colspan="1">0.48</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.09</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.05</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.43</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.08</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.08</td><td align="center" valign="middle" rowspan="1" colspan="1">0.07</td><td align="center" valign="middle" rowspan="1" colspan="1">0.31</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.23</td><td align="center" valign="middle" rowspan="1" colspan="1">0.07</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Cyclic</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 1</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.82</td><td align="center" valign="middle" rowspan="1" colspan="1">0.42</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.05</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">1.65</td><td align="center" valign="middle" rowspan="1" colspan="1">0.55</td><td align="center" valign="middle" rowspan="1" colspan="1">0.37</td><td align="center" valign="middle" rowspan="1" colspan="1">0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">1.31</td><td align="center" valign="middle" rowspan="1" colspan="1">0.2</td><td align="center" valign="middle" rowspan="1" colspan="1">0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">0.44</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.32</td><td align="center" valign="middle" rowspan="1" colspan="1">0.71</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 2</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.55</td><td align="center" valign="middle" rowspan="1" colspan="1">0.4</td><td align="center" valign="middle" rowspan="1" colspan="1">0.17</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.23</td><td align="center" valign="middle" rowspan="1" colspan="1">1.32</td><td align="center" valign="middle" rowspan="1" colspan="1">0.35</td><td align="center" valign="middle" rowspan="1" colspan="1">0.3</td><td align="center" valign="middle" rowspan="1" colspan="1">`</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.27</td><td align="center" valign="middle" rowspan="1" colspan="1">0.97</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.32</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.27</td><td align="center" valign="middle" rowspan="1" colspan="1">0.80</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 3</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.94</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.53</td><td align="center" valign="middle" rowspan="1" colspan="1">0.49</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">0.94</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.30</td><td align="center" valign="middle" rowspan="1" colspan="1">0.33</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.82</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.28</td><td align="center" valign="middle" rowspan="1" colspan="1">0.22</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 4</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.6</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.37</td><td align="center" valign="middle" rowspan="1" colspan="1">0.64</td><td align="center" valign="middle" rowspan="1" colspan="1">0.09</td><td align="center" valign="middle" rowspan="1" colspan="1">0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">0.56</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.22</td><td align="center" valign="middle" rowspan="1" colspan="1">0.40</td><td align="center" valign="middle" rowspan="1" colspan="1">0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">0.41</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">0.44</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 5</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.3</td><td align="center" valign="middle" rowspan="1" colspan="1">0.27</td><td align="center" valign="middle" rowspan="1" colspan="1">0.28</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.24</td><td align="center" valign="middle" rowspan="1" colspan="1">0.83</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.17</td><td align="center" valign="middle" rowspan="1" colspan="1">0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.08</td><td align="center" valign="middle" rowspan="1" colspan="1">0.60</td><td align="center" valign="middle" rowspan="1" colspan="1">0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">0.65</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 6</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.32</td><td align="center" valign="middle" rowspan="1" colspan="1">0.29</td><td align="center" valign="middle" rowspan="1" colspan="1">0.27</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">0.88</td><td align="center" valign="middle" rowspan="1" colspan="1">0.32</td><td align="center" valign="middle" rowspan="1" colspan="1">0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.76</td><td align="center" valign="middle" rowspan="1" colspan="1">0.33</td><td align="center" valign="middle" rowspan="1" colspan="1">0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.11</td><td align="center" valign="middle" rowspan="1" colspan="1">0.77</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 7</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.32</td><td align="center" valign="middle" rowspan="1" colspan="1">0.34</td><td align="center" valign="middle" rowspan="1" colspan="1">0.35</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.35</td><td align="center" valign="middle" rowspan="1" colspan="1">0.98</td><td align="center" valign="middle" rowspan="1" colspan="1">0.3</td><td align="center" valign="middle" rowspan="1" colspan="1">0.23</td><td align="center" valign="middle" rowspan="1" colspan="1">0.2</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.17</td><td align="center" valign="middle" rowspan="1" colspan="1">0.77</td><td align="center" valign="middle" rowspan="1" colspan="1">0.24</td><td align="center" valign="middle" rowspan="1" colspan="1">0.17</td><td align="center" valign="middle" rowspan="1" colspan="1">0.18</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.60</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 8</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.04</td><td align="center" valign="middle" rowspan="1" colspan="1">0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">0.86</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.44</td><td align="center" valign="middle" rowspan="1" colspan="1">0.52</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">0.9</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.28</td><td align="center" valign="middle" rowspan="1" colspan="1">0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">0.07</td><td align="center" valign="middle" rowspan="1" colspan="1">0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">0.62</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.22</td><td align="center" valign="middle" rowspan="1" colspan="1">0.36</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 9</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.09</td><td align="center" valign="middle" rowspan="1" colspan="1">0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.65</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.50</td><td align="center" valign="middle" rowspan="1" colspan="1">0.31</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.11</td><td align="center" valign="middle" rowspan="1" colspan="1">0.83</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">0.04</td><td align="center" valign="middle" rowspan="1" colspan="1">0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.72</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.30</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 10</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.1</td><td align="center" valign="middle" rowspan="1" colspan="1">0.24</td><td align="center" valign="middle" rowspan="1" colspan="1">0.69</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.38</td><td align="center" valign="middle" rowspan="1" colspan="1">0.57</td><td align="center" valign="middle" rowspan="1" colspan="1">0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.2</td><td align="center" valign="middle" rowspan="1" colspan="1">0.29</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">0.62</td><td align="center" valign="middle" rowspan="1" colspan="1">0.24</td><td align="center" valign="middle" rowspan="1" colspan="1">0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">0.22</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">0.63</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 11</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.25</td><td align="center" valign="middle" rowspan="1" colspan="1">0.3</td><td align="center" valign="middle" rowspan="1" colspan="1">0.41</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.34</td><td align="center" valign="middle" rowspan="1" colspan="1">0.84</td><td align="center" valign="middle" rowspan="1" colspan="1">0.1</td><td align="center" valign="middle" rowspan="1" colspan="1">0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">0.6</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.29</td><td align="center" valign="middle" rowspan="1" colspan="1">0.49</td><td align="center" valign="middle" rowspan="1" colspan="1">0.06</td><td align="center" valign="middle" rowspan="1" colspan="1">0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">0.68</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.23</td><td align="center" valign="middle" rowspan="1" colspan="1">0.34</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 12</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.29</td><td align="center" valign="middle" rowspan="1" colspan="1">0.28</td><td align="center" valign="middle" rowspan="1" colspan="1">0.31</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.27</td><td align="center" valign="middle" rowspan="1" colspan="1">0.84</td><td align="center" valign="middle" rowspan="1" colspan="1">0.44</td><td align="center" valign="middle" rowspan="1" colspan="1">0.3</td><td align="center" valign="middle" rowspan="1" colspan="1">0.16</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">1.06</td><td align="center" valign="middle" rowspan="1" colspan="1">0.44</td><td align="center" valign="middle" rowspan="1" colspan="1">0.29</td><td align="center" valign="middle" rowspan="1" colspan="1">0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.17</td><td align="center" valign="middle" rowspan="1" colspan="1">1.04</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 13</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.1</td><td align="center" valign="middle" rowspan="1" colspan="1">0.19</td><td align="center" valign="middle" rowspan="1" colspan="1">0.61</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.28</td><td align="center" valign="middle" rowspan="1" colspan="1">0.48</td><td align="center" valign="middle" rowspan="1" colspan="1">0.04</td><td align="center" valign="middle" rowspan="1" colspan="1">0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.75</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.21</td><td align="center" valign="middle" rowspan="1" colspan="1">0.30</td><td align="center" valign="middle" rowspan="1" colspan="1">0.09</td><td align="center" valign="middle" rowspan="1" colspan="1">0.2</td><td align="center" valign="middle" rowspan="1" colspan="1">0.65</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.32</td><td align="center" valign="middle" rowspan="1" colspan="1">0.51</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 14</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.1</td><td align="center" valign="middle" rowspan="1" colspan="1">0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.39</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">0.34</td><td align="center" valign="middle" rowspan="1" colspan="1">0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">0.38</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.15</td><td align="center" valign="middle" rowspan="1" colspan="1">0.38</td><td align="center" valign="middle" rowspan="1" colspan="1">0.14</td><td align="center" valign="middle" rowspan="1" colspan="1">0.13</td><td align="center" valign="middle" rowspan="1" colspan="1">0.28</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">0.41</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Shift 15</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>BMI</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.05</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.01</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.08</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.01</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.06</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Age</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.12</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.04</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.01</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.01</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Female</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.93</td><td align="center" valign="middle" rowspan="1" colspan="1">0.26</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.01</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;1.47</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.39</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.3</td><td align="center" valign="middle" rowspan="1" colspan="1">0.1</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.05</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.49</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.10</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.06</td><td align="center" valign="middle" rowspan="1" colspan="1">0.08</td><td align="center" valign="middle" rowspan="1" colspan="1">0.45</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.23</td><td align="center" valign="middle" rowspan="1" colspan="1">0.11</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>Male</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td><td align="center" valign="middle" rowspan="1" colspan="1">.</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>LA60+</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.44</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.03</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.56</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.24</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>RA60+</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.05</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.04</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.79</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.55</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>FE90P</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>&#x0003c;0.05</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.16</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.45</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td></tr><tr><td align="center" valign="middle" rowspan="1" colspan="1">
<bold>RANLS</bold>
</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0.78</td><td align="center" valign="middle" rowspan="1" colspan="1">&#x02212;0.02</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.53</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0</td><td align="center" valign="middle" rowspan="1" colspan="1">0.09</td><td align="center" valign="middle" rowspan="1" colspan="1">0.00</td><td align="center" valign="middle" rowspan="1" colspan="1">0.01</td></tr></tbody></table><table-wrap-foot><fn id="TFN8"><p id="P79">Estimate = An estimate of the slope for each effect in the model (i.e., beta coefficient).</p></fn><fn id="TFN9"><p id="P80">Std. Error = Standard error of the estimate.</p></fn><fn id="TFN10"><p id="P81"><italic toggle="yes">p</italic> = <italic toggle="yes">p</italic>-value corresponding to the t-statistic.</p></fn><fn id="TFN11"><p id="P82">95% CI Lower = 95 percent confidence interval lower bound.</p></fn><fn id="TFN12"><p id="P83">95% CI Upper = 95 percent confidence interval upper bound.</p></fn><fn id="TFN13"><p id="P84">LA60+ = percentage of time with the left arm elevated &#x02265; 60&#x000b0;.</p></fn><fn id="TFN14"><p id="P85">RA60+ = percentage of time with the right arm elevated &#x02265; 60&#x000b0;.</p></fn><fn id="TFN15"><p id="P86">FE90P = the 90th percentile of trunk flexion/extension.</p></fn><fn id="TFN16"><p id="P87">RANLS = percentage of time with the right arm elevated &#x0003c; 20&#x000b0; and moving &#x0003c; 5&#x000b0;/s.</p></fn></table-wrap-foot></table-wrap></floats-group></article>