Emerg Infect DisEIDEmerging Infectious Diseases1080-60401080-6059Centers for Disease Control and Prevention17073112329474506-016210.3201/eid1209.060162Letters to the EditorCommunity-associated Methicillin-resistant Staphylococcus aureusCommunity-associated Methicillin-resistant Staphylococcus aureusHotaBala*WeinsteinRobert A.*Rush University Medical Center, Chicago, Illinois, USA;John H. Stroger Jr. (Cook County) Hospital, Chicago, Illinois, USAAddress for correspondence: Bala Hota, John H. Stroger Jr. (Cook County) Hospital; 637 S. Wood St, Chicago, IL 60612, USA; email: Bala_N_Hota@rush.edu9200612914691474Keywords: SurveillanceInformaticsStaphylococcus aureusletter

To the Editor: Community-associated (CA) methicillin-resistant Staphylococcus aureus (CA-MRSA) is a global emerging threat (17). Accurate measures of the extent of CA-MRSA are critical to allocate resources, guide control measures, and inform prescribing practices (8). We assessed the utility of administrative databases, a computerized clinical data repository, and an electronic rule to enhance surveillance for CA-MRSA at Stroger (Cook County) Hospital, a 464-bed public safety net hospital in Chicago, and its associated clinics—all part of the Cook County Bureau of Health Services (CCBHS).

Using data collected within the Chicago Antimicrobial Resistance Project computerized clinical data repository (9) from September 1, 2001, to August 31, 2004, we developed an electronic rule to define persons with CA infection with S. aureus. This rule used the electronic records of all persons from whom MRSA or methicillin-susceptible S. aureus (MSSA) had been identified in cultures of soft tissue, pus, bone, or joints. Infections from patients who met the following electronic case definition were designated CA: 1) culture obtained as an outpatient or within the first 3 days of hospitalization, 2) no clinical culture with MRSA in the last 6 months, 3) no hospitalization or surgeries within 1 year, and 4) no hemodialysis. All other infections were defined as healthcare associated. Data for microbiology results, demographics, and recent surgery or hospitalization were linked by a unique patient identification number. Dialysis use was detected by the use of biochemical tests obtained around the time of dialysis or of hemodialyis-related ICD-9 procedure codes (39.27, 90945, 39.95, 90935, 54.98, 39.43, 39.42, or 38.95). Because the electronic data sources were complete for the period specified, absence of data for a patient was considered to be due to the absence of exposure, not missing data.

Using the electronic case definition and data repository, we randomly selected 100 patients with putative CA- and 100 with putative healthcare-associated S. aureus infections. The paper charts for these 200 patients were reviewed to validate the designations of CA- or healthcare-associated infection, by using the same criteria as for the electronic rule. To ensure blinding for manual chart reviews, all references to results of the electronic rule were removed from data collection instruments. Using information obtained from chart review as the standard, we determined sensitivity and specificity of the electronic rule and calculated agreement (κ statistic) between manual and electronic reviews. To ascertain data sources of most value in detecting healthcare exposures, we examined data tables required for each type of exposure and for coincident exposures to develop more parsimonious data requirements.

During the study period, 714 (386 MSSA and 328 MRSA) healthcare-associated and 1,222 (518 MRSA and 704 MSSA) CA infections occurred; all electronic data elements were available for all patient encounters that occurred within CCBHS. Sampling yielded 47 CA- and 52 healthcare-associated MRSA infections and 53 CA- and 48 healthcare-associated MSSA infections.

The electronic case definition performed well when compared with chart review. All 100 healthcare-associated infections identified electronically were confirmed by manual chart review as classified correctly. Among the 100 community-associated infections identified electronically, 3 (3%) were determined by chart review to have been misclassified: 2 patients had been hospitalized, and a third had surgery within the previous year, all outside CCBHS. The sensitivity of the electronic case definition for community association was 100%; specificity was 97%. The κ statistic was 0.97 (confidence interval [CI] 0.83–1.00), which indicated superior agreement between chart review and electronic rule. For misclassified cases, 1 infection was due to MRSA, and 2 were due to MSSA. The performance characteristics of the rule for CA-MRSA were sensitivity 100%, specificity 98.1%, and κ = 0.98 (CI 0.78–1.00).

The Table describes data elements required to detect healthcare exposures. The most data-intensive exposure to detect was hemodialysis, which required a search of laboratory and discharge diagnosis databases. Isolates of MRSA were designated healthcare-associated most commonly because of prior hospitalization (523 [73%] of 714) and date of culture (i.e., >3 days after hospital admission) (259 [36%] of 714). With the use of only admission/discharge and microbiology data, 28 patients (90%) who had undergone dialysis and 23 (85%) who had undergone surgery were identified. The use of only admission/discharge and microbiology data would have detected 707 patients, 99% of those who would have been detected by the full algorithm.

Data sources for healthcare exposures
Healthcare exposureDatabases neededComments
Isolate obtained >3 d after admissionMicrobiology laboratoryMicrobiology table must contain patient registration date to compare with culture date
HemodialysisDischarge diagnoses, biochemistry laboratoryBiochemistry laboratory table must contain location of test to identify dialysis clinic
Prior hospitalization (within 1 y)Admission, discharge, and transfer dataQuery must be able to compare individual patients across admissions
Prior surgeries (within 1 y)Operating room schedulesMay not be readily available in many institutions
Prior isolation of MRSA* (within 6 mo)Microbiology laboratoryQuery must be able to compare individual patients across admissions

*MRSA, methicillin-resistant Staphylococcus aureus.

Our study had limitations. Chart review may have undercounted healthcare-associated factors and is dependent on clinician histories and documentation. However, retrospective review of paper charts is the principal method that infection control practitioners use to gather information. Also, this study was conducted at a single center that served a population that may have had difficulty seeking care elsewhere. For single hospitals or systems with a less captive population, electronic measures may not function as well until disparate systems can be integrated, i.e., at the level of health departments or through data sharing among regional health information organizations.

In conclusion, using easily accessible data from a computerized clinical data repository, we readily classified S. aureus and MRSA infections as CA or healthcare associated. Comparison of the electronic method with manual paper chart review demonstrated high agreement for MRSA (κ = 0.98). Additional review suggested that use of only 1 or 2 data sources efficiently detected prior healthcare exposures. A major dividend of increased use of information technology in healthcare is application of electronically stored data to improve public health surveillance.

Suggested citation for this article: Hota B, Weinstein RA. Methicillin-resistant Staphylococcus aureus [letter]. Emerg Infect Dis [serial on the Internet]. 2006 Sep [date cited]. http://dx.doi.org/10.3201/eid1209.060162

ReferencesFridkin SK, Hageman JC, Morrison M, Sanza LT, Como-Sabetti K, Jernigan JA, Methicillin-resistant Staphylococcus aureus disease in three communities. N Engl J Med. 2005;352:143644 10.1056/NEJMoa04325215814879Buckingham SC, McDougal LK, Cathey LD, Comeaux K, Craig AS, Fridkin SK, Emergence of community-associated methicillin-resistant Staphylococcus aureus at a Memphis, Tennessee Children’s Hospital. Pediatr Infect Dis J. 2004;23:61924 10.1097/01.inf.0000131981.67342.c415247599Naimi TS, LeDell KH, Como-Sabetti K, Borchardt SM, Boxrud DJ, Etienne J, Comparison of community- and health care-associated methicillin-resistant Staphylococcus aureus infection. JAMA. 2003;290:297684 10.1001/jama.290.22.297614665659Gravet A, Couppie P, Meunier O, Clyti E, Moreau B, Pradinaud R, Staphylococcus aureus isolated in cases of impetigo produces both epidermolysin A or B and LukE-LukD in 78% of 131 retrospective and prospective cases. J Clin Microbiol. 2001;39:434956 10.1128/JCM.39.12.4349-4356.200111724844Zinderman CE, Conner B, Malakooti MA, LaMar JE, Armstrong A, Bohnker BK Community-acquired methicillin-resistant Staphylococcus aureus among military recruits. Emerg Infect Dis. 2004;10:941415200838Abraham J, Mansour C, Veledar E, Khan B, Lerakis S Staphylococcus aureus bacteremia and endocarditis: the Grady Memorial Hospital experience with methicillin-sensitive S. aureus and methicillin-resistant S. aureus bacteremia. Am Heart J. 2004;147:5369 10.1016/j.ahj.2003.09.01814999206Stemper ME, Shukla SK, Reed KD Emergence and spread of community-associated methicillin-resistant Staphylococcus aureus in rural Wisconsin, 1989 to 1999. J Clin Microbiol. 2004;42:567380 10.1128/JCM.42.12.5673-5680.200415583298Chambers HF Community-associated MRSA–resistance and virulence converge. N Engl J Med. 2005;352:14857 10.1056/NEJMe05802315814886Wisniewski MF, Kieszkowski P, Zagorski BM, Trick WE, Sommers M, Weinstein RA Development of a clinical data warehouse for hospital infection control. J Am Med Inform Assoc. 2003;10:45462 Epub 2003 Jun 4 10.1197/jamia.M129912807807