<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.3 20210610//EN" "JATS-archivearticle1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">9886760</journal-id><journal-id journal-id-type="pubmed-jr-id">22903</journal-id><journal-id journal-id-type="nlm-ta">Aerosol Sci Technol</journal-id><journal-id journal-id-type="iso-abbrev">Aerosol Sci Technol</journal-id><journal-title-group><journal-title>Aerosol science and technology : the journal of the American Association for Aerosol Research</journal-title></journal-title-group><issn pub-type="ppub">0278-6826</issn></journal-meta><article-meta><article-id pub-id-type="pmid">37736266</article-id><article-id pub-id-type="pmc">10512808</article-id><article-id pub-id-type="doi">10.1080/02786826.2019.1600654</article-id><article-id pub-id-type="manuscript">HHSPA1923255</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Evaluation of a Portable Aerosol Collector and Spectrometer to measure particle concentration by composition and size</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Cai</surname><given-names>Changjie</given-names></name><xref rid="A1" ref-type="aff">a</xref></contrib><contrib contrib-type="author"><name><surname>Stebounova</surname><given-names>Larissa V.</given-names></name><xref rid="A2" ref-type="aff">b</xref></contrib><contrib contrib-type="author"><name><surname>Peate</surname><given-names>David W.</given-names></name><xref rid="A3" ref-type="aff">c</xref></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0002-1698-8856</contrib-id><name><surname>Peters</surname><given-names>Thomas M.</given-names></name><xref rid="A2" ref-type="aff">b</xref></contrib></contrib-group><aff id="A1"><label>a</label>Department of Occupational and Environmental Health, University of Oklahoma Health Sciences Center, University of Oklahoma, Oklahoma City, Oklahoma, USA</aff><aff id="A2"><label>b</label>Department of Occupational and Environmental Health, The University of Iowa, Iowa City, Iowa, USA</aff><aff id="A3"><label>c</label>Department of Earth and Environmental Sciences, The University of Iowa, Iowa City, Iowa, USA</aff><author-notes><corresp id="CR1"><bold>CONTACT</bold> Thomas M. Peters <email>Thomas-m-peters@uiowa.edu</email> Department of Occupational and Environmental Health, The University of Iowa, 145 N Riverside Dr, S325 CPHB, Iowa City, IA 52242, USA.</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>25</day><month>8</month><year>2023</year></pub-date><pub-date pub-type="ppub"><day>03</day><month>6</month><year>2019</year></pub-date><pub-date pub-type="pmc-release"><day>21</day><month>9</month><year>2023</year></pub-date><volume>53</volume><issue>6</issue><fpage>675</fpage><lpage>687</lpage><abstract id="ABS1"><p id="P1">We evaluated a newly developed Portable Aerosol Collector and Spectrometer (PACS) in the laboratory. We developed an algorithm to estimate mass concentration by size and composition with a PACS. In laboratory experiments, we compared particle size distributions measured with the PACS to research instruments for multi-modal aerosols: two-mode generated by spark discharge, consisting of ultrafine (fresh Mn fume) and fine particles (aged Cu fume); and three-mode produced by adding coarse particles (Arizona road dust) to the two-mode. Near-real-time size distributions from the PACS compared favorably to those from a scanning mobility particle sizer and an aerodynamic particle sizer for the three-mode aerosol (number, <inline-formula><mml:math id="M1" display="inline"><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mspace width="0.25em"/><mml:mo>=</mml:mo><mml:mspace width="0.25em"/><mml:mn>9.4</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M2" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.96</mml:mn></mml:math></inline-formula>; surface area, <inline-formula><mml:math id="M3" display="inline"><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mspace width="0.25em"/><mml:mo>=</mml:mo><mml:mspace width="0.25em"/><mml:mn>17.8</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M4" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.77</mml:mn></mml:math></inline-formula>; mass, <inline-formula><mml:math id="M5" display="inline"><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mspace width="0.25em"/><mml:mo>=</mml:mo><mml:mspace width="0.25em"/><mml:mo>-</mml:mo><mml:mn>2.2</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M6" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.94</mml:mn></mml:math></inline-formula>), but less so for the two-mode aerosol (number, <inline-formula><mml:math id="M7" display="inline"><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mspace width="0.25em"/><mml:mo>=</mml:mo><mml:mspace width="0.25em"/><mml:mo>-</mml:mo><mml:mn>17.7</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M8" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.51</mml:mn></mml:math></inline-formula>; surface area, <inline-formula><mml:math id="M9" display="inline"><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mspace width="0.25em"/><mml:mo>=</mml:mo><mml:mspace width="0.25em"/><mml:mo>-</mml:mo><mml:mn>45.5</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M10" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0</mml:mn></mml:math></inline-formula>; for mass, <inline-formula><mml:math id="M11" display="inline"><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mspace width="0.25em"/><mml:mo>=</mml:mo><mml:mspace width="0.25em"/><mml:mo>-</mml:mo><mml:mn>81.75</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>, <inline-formula><mml:math id="M12" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.08</mml:mn></mml:math></inline-formula>). Elemental mass concentrations by size were similar to those measured with a nano micro-orifice uniform deposition impactor for coarse-mode particles, whereas agreement was considerably poorer for ultrafine- and fine-mode particles. The PACS has merit in estimating multi-metric concentrations by size and composition but requires further research to resolve discrepancies identified for two-mode aerosol.</p></abstract></article-meta></front><body><sec id="S1"><label>1.</label><title>Introduction</title><p id="P2">Adverse health effects from inhaled aerosols are a complicated function of aerosol size, composition, and concentration (<xref rid="R9" ref-type="bibr">Harrison and Yin 2000</xref>). Particles deposit in different regions of the respiratory system according to their size and shape, whereas the adverse health effects potentially resulting from these deposited particles depend on particle composition (<xref rid="R10" ref-type="bibr">Hinds 1999</xref>; <xref rid="R21" ref-type="bibr">Valavanidis, Fiotakis, and Vlachogianni 2008</xref>). Moreover, three concentration metrics (number, surface area and mass) are considered as predictors of various adverse health effects for different size particles (<xref rid="R12" ref-type="bibr">Kittelson 1998</xref>; <xref rid="R4" ref-type="bibr">Brouwer, Gijsbers, and Lurvink 2004</xref>; <xref rid="R18" ref-type="bibr">Ramachandran et al. 2005</xref>; <xref rid="R6" ref-type="bibr">Ellenbecker and Tsai 2015</xref>).</p><p id="P3">A combination of commercially available research instruments is needed to assess aerosol exposures by size, composition, and multiple concentration metrics. Some instruments provide a way to continuously measure aerosol number concentrations by size, such as the scanning mobility particle sizer (SMPS, ~$70,000) for measuring the sub-micrometer particles by equivalent mobility particle diameter, and the aerodynamic particle sizer (APS, ~$50,000) for measuring particles larger than ~0.7 <italic toggle="yes">&#x003bc;</italic>m by aerodynamic particle diameter (<xref rid="R3" ref-type="bibr">Baron 1986</xref>; <xref rid="R22" ref-type="bibr">Wang and Flagan 1990</xref>). Surface area and mass size distributions can be estimated reasonably well with the SMPS and APS because the number concentrations are highly resolved by size. Such estimates, however, are improved with knowledge of particle density and shape factor, which is not available from these instruments. Other device, such as the nano micro-orifice uniform deposit impactor (nanoMOUDI, ~$60,000), can collect particles by size onto substrates for subsequent chemical analysis, such as an inductively coupled plasma-mass spectrometry (ICP-MS) (<xref rid="R14" ref-type="bibr">Marple, Rubow, and Behm 1991</xref>; <xref rid="R11" ref-type="bibr">Karthikeyan, Joshi, and Balasubramanian 2006</xref>; <xref rid="R13" ref-type="bibr">Kulkarni et al. 2007</xref>). Combined, the SMPS, APS, and nanoMOUDI provide near-real-time size distributions by metric and composition. However, they are expensive, large, and heavy, limiting their use to research studies.</p><p id="P4">Previously, we introduced a new device&#x02014;the Portable Aerosol Collector and Spectrometer (PACS)&#x02014;designed to estimate aerosol size distributions of three metrics (number, surface area and mass concentration) in near-real-time (&#x0003c;3 min), and to collect particles to determine mass concentration by size and composition. Introduced by <xref rid="R5" ref-type="bibr">Cai et al. (2018)</xref>, the PACS hardware consists of a six-stage particle size selector, a valve system, a water condensation particle counter (WCPC) to detect number concentrations, and a photometer to detect mass concentrations. The valve system diverts airflow to pass sequentially through each stage of the selector to the detectors. The first stage of the selector allows aerosol entering the inlet to freely pass through to the valve manifold. The next three impactor stages collect particles by single-hole impactors with measured 50% collection efficiency cutoff aerodynamic diameters, <inline-formula><mml:math id="M13" display="inline"><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mn>50</mml:mn></mml:mrow></mml:msub><mml:mi>s</mml:mi></mml:math></inline-formula>, of 10 &#x003bc;m, 1 &#x003bc;m, and 0.4 &#x003bc;m. The last two stages collect particles by diffusion with measured <inline-formula><mml:math id="M14" display="inline"><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mn>50</mml:mn></mml:mrow></mml:msub><mml:mi>s</mml:mi></mml:math></inline-formula> of 16 nm and 56 nm of geometric diameter, respectively. A software program sequentially opens one valve at a time to obtain six number and six mass concentrations every 3 min. <xref rid="R5" ref-type="bibr">Cai et al. (2018)</xref> developed a multi-modal log-normal (MMLN) fitting algorithm that leverages these low-resolution, two-metric measurements to estimate number, surface area, and mass concentration highly resolved by size from 10 nm to 10 &#x003bc;m in near-real-time.</p><p id="P5">In this study, we had two objectives: (1) to develop an algorithm to estimate the mass distribution of an aerosol by size and composition using data from the chemical analysis of particles collected on the stages of the PACS size selector; and (2) to compare particle size distributions measured for multi-modal aerosols with the PACS to those measured with SMPS, APS, and nanoMOUDI in the laboratory. We compared the near-real-time number, surface area and mass concentrations by size measured with the PACS to those measured with the SMPS/APS and mass concentrations by composition and size measured with the PACS to those measured with the nanoMOUDI.</p></sec><sec id="S2"><label>2.</label><title>Methods</title><sec id="S3"><label>2.1.</label><title>Description of the algorithm</title><p id="P6">We developed a new algorithm&#x02014;the mass distribution by composition and size (MDCS) algorithm&#x02014;to estimate mass concentration by composition and size from analysis of particles collected on the stages of the PACS size separator (<xref rid="F1" ref-type="fig">Figure 1</xref>). The algorithm has three inputs: (1) the mass of each element <inline-formula><mml:math id="M15" display="inline"><mml:mi>e</mml:mi></mml:math></inline-formula> from analysis (in this work, chemical analysis by ICP-MS) of particles collected in each PACS stage <inline-formula><mml:math id="M16" display="inline"><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mspace width="0.25em"/><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>I</mml:mi><mml:mi>C</mml:mi><mml:mi>P</mml:mi></mml:mrow></mml:msub><mml:mo>;</mml:mo></mml:math></inline-formula> (2) the collection efficiency of particles by size <inline-formula><mml:math id="M17" display="inline"><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> for each PACS stage <inline-formula><mml:math id="M18" display="inline"><mml:mfenced close="" separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>C</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced></mml:math></inline-formula>, experimentally determined by <xref rid="R5" ref-type="bibr">Cai et al. (2018)</xref>; equivalent mobility diameter for particles smaller than ~700 nm and aerodynamic diameter for particles larger than ~700 nm); (3) output from the MMLN algorithm including, for each particle size mode <inline-formula><mml:math id="M19" display="inline"><mml:mi>i</mml:mi></mml:math></inline-formula>, the mass concentration by size <inline-formula><mml:math id="M20" display="inline"><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced></mml:math></inline-formula>, the mass median diameter <inline-formula><mml:math id="M21" display="inline"><mml:mfenced separators="|"><mml:mrow><mml:mi>M</mml:mi><mml:mi>M</mml:mi><mml:msub><mml:mrow><mml:mi>D</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula>, and geometric standard deviation <inline-formula><mml:math id="M22" display="inline"><mml:mfenced separators="|"><mml:mrow><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:msub><mml:mrow><mml:mi>D</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula>. We used a trimodal, log-normal distribution to mathematically express the mass size distribution of a particle for a given composition:
<disp-formula id="FD1">
<label>(1)</label>
<mml:math id="M23" display="block"><mml:mrow><mml:mi>f</mml:mi><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:msub><mml:mi>M</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:mi>M</mml:mi><mml:mi>M</mml:mi><mml:msub><mml:mi>D</mml:mi><mml:mi>i</mml:mi></mml:msub><mml:mo>,</mml:mo><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:msub><mml:mi>D</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mo>=</mml:mo><mml:munderover><mml:mo>&#x02211;</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn>1</mml:mn></mml:mrow><mml:mn>3</mml:mn></mml:munderover><mml:mfrac><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow><mml:mrow><mml:msqrt><mml:mrow><mml:mn>2</mml:mn><mml:mi>&#x003c0;</mml:mi></mml:mrow></mml:msqrt><mml:mtext>ln</mml:mtext><mml:mfenced><mml:mrow><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:msub><mml:mi>D</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac><mml:mtext>exp</mml:mtext><mml:mfenced close="]" open="["><mml:mrow><mml:mo>&#x02212;</mml:mo><mml:mfrac><mml:mrow><mml:msup><mml:mrow><mml:mfenced close="]" open="["><mml:mrow><mml:mi>l</mml:mi><mml:mi>n</mml:mi><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mo>&#x02212;</mml:mo><mml:mi>l</mml:mi><mml:mi>n</mml:mi><mml:mfenced><mml:mrow><mml:mi>M</mml:mi><mml:mi>M</mml:mi><mml:msub><mml:mi>D</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow><mml:mrow><mml:mn>2</mml:mn><mml:msup><mml:mrow><mml:mi>l</mml:mi><mml:mi>n</mml:mi></mml:mrow><mml:mn>2</mml:mn></mml:msup><mml:mfenced><mml:mrow><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:msub><mml:mi>D</mml:mi><mml:mi>i</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac></mml:mrow></mml:mfenced></mml:mrow></mml:math>
</disp-formula></p><p id="P7">For each element, we adjust <inline-formula><mml:math id="M24" display="inline"><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>I</mml:mi><mml:mi>C</mml:mi><mml:mi>P</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> (Input 1) for the fact that lower volumes of air pass through each successive stage as follows:
<disp-formula id="FD2">
<label>(2)</label>
<mml:math id="M25" display="block"><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>I</mml:mi><mml:mi>C</mml:mi><mml:mi>P</mml:mi></mml:mrow></mml:msub><mml:mo>&#x000d7;</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>t</mml:mi></mml:mrow><mml:mrow><mml:mi>t</mml:mi><mml:mi>o</mml:mi><mml:mi>t</mml:mi><mml:mi>a</mml:mi><mml:mi>l</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>t</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M26" display="inline"><mml:msub><mml:mrow><mml:mi>t</mml:mi></mml:mrow><mml:mrow><mml:mi>t</mml:mi><mml:mi>o</mml:mi><mml:mi>t</mml:mi><mml:mi>a</mml:mi><mml:mi>l</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> is the total time of one PACS measurement cycle, and <inline-formula><mml:math id="M27" display="inline"><mml:msub><mml:mrow><mml:mi>t</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> is the time that air passes through a given stage during that sequence. The air volume sampled differs because the stages are in series and the valves open sequentially one at a time. For one cycle given the current arrangement of the PACS with each valve open for 30 s the total time is 180 s and the time that air passes through Stage 1 is 150 s, Stage 2 is 120 s, Stage 3 is 90 s, Stage 4 is 60 s, and Stage 5 is 30 s. Using <inline-formula><mml:math id="M28" display="inline"><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>I</mml:mi><mml:mi>C</mml:mi><mml:mi>P</mml:mi><mml:mo>-</mml:mo><mml:mi>M</mml:mi><mml:mi>S</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> values that are greater than the limit of detection (LOD), we assign the element to a mode(s) as follows: (1) all modes, if mass detected in impactor and diffusion stages; (2) fine and coarse modes, if mass in all three impactor stages only; (3) coarse mode, if mass in the first two impactor stages only; (4) ultrafine and fine modes, if mass in diffusion stages only; and (5) ultrafine mode, if mass in first diffusion stage only.</p><p id="P8">We multiply <inline-formula><mml:math id="M29" display="inline"><mml:msub><mml:mrow><mml:mi>C</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula> from Input 2 by <inline-formula><mml:math id="M30" display="inline"><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula> from Input 3 to calculate the mass concentration of each mode in each stage by size:
<disp-formula id="FD3">
<label>(3)</label>
<mml:math id="M31" display="block"><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced><mml:mo>=</mml:mo><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced><mml:mo>&#x000d7;</mml:mo><mml:msub><mml:mrow><mml:mi>C</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math>
</disp-formula></p><p id="P9">Assuming that the mode structure is the same as the mode structure identified by the MMLN algorithm (<xref rid="R5" ref-type="bibr">Cai et al. 2018</xref>), we calculate the mass fraction of each mode among all three modes in each stage as:
<disp-formula id="FD4">
<label>(4)</label>
<mml:math id="M32" display="block"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>e</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mrow><mml:munderover><mml:mo>&#x0222b;</mml:mo><mml:mn>0</mml:mn><mml:mi>&#x0221e;</mml:mi></mml:munderover><mml:mrow><mml:msub><mml:mo>&#x02211;</mml:mo><mml:mi>i</mml:mi></mml:msub><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mrow></mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mi>d</mml:mi><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mrow><mml:munderover><mml:mo>&#x0222b;</mml:mo><mml:mn>0</mml:mn><mml:mi>&#x0221e;</mml:mi></mml:munderover><mml:mrow><mml:msubsup><mml:mo>&#x02211;</mml:mo><mml:mrow><mml:mi>i</mml:mi><mml:mo>=</mml:mo><mml:mn>1</mml:mn></mml:mrow><mml:mn>3</mml:mn></mml:msubsup><mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mrow></mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mi>d</mml:mi><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula></p><p id="P10">We also calculate the mass fraction of each stage among all six stages of each mode as:
<disp-formula id="FD5">
<label>(5)</label>
<mml:math id="M33" display="block"><mml:mrow><mml:msub><mml:mi>F</mml:mi><mml:mrow><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>e</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mrow><mml:munderover><mml:mo>&#x0222b;</mml:mo><mml:mn>0</mml:mn><mml:mi>&#x0221e;</mml:mi></mml:munderover><mml:mrow><mml:msub><mml:mo>&#x02211;</mml:mo><mml:mi>k</mml:mi></mml:msub><mml:msub><mml:mi>M</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mrow><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mi>d</mml:mi><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mrow><mml:munderover><mml:mo>&#x0222b;</mml:mo><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn>0</mml:mn></mml:mrow><mml:mn>5</mml:mn></mml:munderover><mml:mrow><mml:msubsup><mml:mo>&#x02211;</mml:mo><mml:mrow><mml:mi>k</mml:mi><mml:mo>=</mml:mo><mml:mn>0</mml:mn></mml:mrow><mml:mn>5</mml:mn></mml:msubsup></mml:mrow></mml:mrow><mml:msub><mml:mi>M</mml:mi><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced><mml:mi>d</mml:mi><mml:mfenced><mml:mrow><mml:msub><mml:mi>d</mml:mi><mml:mi>p</mml:mi></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula></p><p id="P11">We then calculate the mass concentration in each mode as:
<disp-formula id="FD6">
<label>(6)</label>
<mml:math id="M34" display="block"><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mspace width="0.25em"/><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mo>&#x000d7;</mml:mo><mml:msub><mml:mrow><mml:mi>F</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>e</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mrow><mml:msub><mml:mrow><mml:mi>F</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>i</mml:mi><mml:mo>,</mml:mo><mml:mi>e</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo>&#x000d7;</mml:mo><mml:mfrac><mml:mrow><mml:mn>1</mml:mn></mml:mrow><mml:mrow><mml:mi>Q</mml:mi><mml:mo>&#x000d7;</mml:mo><mml:mi>t</mml:mi></mml:mrow></mml:mfrac></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M35" display="inline"><mml:mi>Q</mml:mi></mml:math></inline-formula> is the PACS flowrate, and <inline-formula><mml:math id="M36" display="inline"><mml:mi>t</mml:mi></mml:math></inline-formula> is the sampling time.</p><p id="P12">For each element, we obtain the <inline-formula><mml:math id="M37" display="inline"><mml:mi>M</mml:mi><mml:mi>M</mml:mi><mml:mi>D</mml:mi></mml:math></inline-formula> and <inline-formula><mml:math id="M38" display="inline"><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:mi>D</mml:mi></mml:math></inline-formula> of each mode output by the MMLN algorithm. We then distribute the mass <inline-formula><mml:math id="M39" display="inline"><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mspace width="0.25em"/><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula> calculated above. The algorithm outputs: (1) composition mass size distribution from 10 nm to 10 <italic toggle="yes">&#x003bc;</italic>m resolved in 40 size bins for each decade of data; (2) summary statistics <inline-formula><mml:math id="M40" display="inline"><mml:mfenced close="" separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi></mml:mrow></mml:msub><mml:mo>,</mml:mo><mml:mspace width="0.25em"/><mml:mi>M</mml:mi><mml:mi>M</mml:mi><mml:mi>D</mml:mi></mml:mrow></mml:mfenced><mml:mo>,</mml:mo><mml:mspace width="0.25em"/><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:mi>D</mml:mi><mml:mo>)</mml:mo></mml:math></inline-formula> for each mode.</p></sec><sec id="S4"><label>2.2.</label><title>Aerosol generation and experimental setup</title><p id="P13">We compared aerosol size distributions measured with the PACS to those measured with research instruments two multi-modal aerosols: (1) a three-mode aerosol with fresh Mn fume for the ultrafine mode (&#x0003c;100 nm), aged Cu fume for the fine mode (100 nm ~ 1 &#x003bc;m) and Arizona road dust for the coarse mode (&#x0003e;1 &#x003bc;m), and (2) a two-mode aerosol with fresh Mn fume for the ultrafine mode and aged Cu fume for the fine mode. The three-mode aerosol was used to mimic the structure observed by <xref rid="R23" ref-type="bibr">Whitby and Sverdrup (1980)</xref> as typical of ambient aerosol, whereas the two-mode aerosol was used to evaluate the PACS under an extreme case (i.e., little mass concentration detected by the photometer without a coarse mode).</p><p id="P14">Fresh Mn fume (ultrafine mode aerosol) was produced with a spark discharge system described previously by <xref rid="R16" ref-type="bibr">Park et al. (2014)</xref> with 5 kV voltage and 3 mA current applied between two identical pure Mn rods (3 mm diameter &#x000d7; 75 mm length, purity 99.5%, Goodfellow Corporation, PA, USA). To produce aged Cu fume (fine mode aerosol), we used a second spark discharge system operated with 5 kV voltage applied between two identical pure Cu rods (3 mm diameter &#x000d7; 75 mm length, purity 99.99%, McMaster-Carr Elmhurst, IL, USA). The aerosol produced with this system was aged as it was passed through two coagulation chambers in series (2 chambers &#x000d7; 200 L each = 400 L). The aerosols produced in the spark chambers were passed through Po-210 neutralizer before entering a mixing chamber. Coarse mode aerosol was produced by aerosolizing Arizona road dust (Fine Grade, Part # 1543094, Powder Technology Inc., Arden Hills, MN, USA) with a fluidized bed aerosol generator (3400A, TSI Inc., Shoreview, MN, USA).</p><p id="P15">Experiments were conducted using a test chamber shown in <xref rid="F2" ref-type="fig">Figure 2</xref>. The chamber consisted of a mixing zone (0.64 m &#x000d7; 0.64 m &#x000d7; 0.66 m) and a sampling zone (0.53 m &#x000d7; 0.64 m &#x000d7; 0.66 m), divided by a perforated plate, which contains 600 evenly spaced holes (0.6 cm in diameter). Room air was filtered with two high efficiency particulate air filters to provide the clean air to the mixing zone. We fed the generated multi-modal aerosols directly into the mixing zone of the test chamber. For each aerosol type, we conducted three experiments, and each experiment lasted 8 h.</p><p id="P16">Measurement instruments were positioned outside the sampling chamber including the PACS, SMPS (SMPS 3936, TSI Inc., Shoreview, MN, USA), APS (APS 3321, TSI Inc., Shoreview, MN, USA), and nanoMOUDI (model 125-R, MSP, Shoreview, MN, USA). The impactor substrates of the PACS were greased to minimize the particle losses. Polycarbonate substrates (0.2 &#x003bc;m pore size, 47 mm diameter, Part # PCT0247100, Sterlitech Corporation, Kent, WA, USA) were cut in-house to 11-mm-diameter circles. A round stamp cut out of foam (37 mm in diameter) dipped into oil (Heavy-Duty Silicone Oil, Part # 07041, MSP Corporation, Shoreview, MN, USA) was pressed onto the middle of polycarbonate substrates to create a layer of silicone oil coating. Greased substrates were baked in the oven at 50 &#x000b0;C for 4 h to evaporate volatile material and create a thin layer of sticky silicone intended to prevent particle bounce (<xref rid="R15" ref-type="bibr">Pak et al. 1992</xref>). The greased filter was attached to pre-oiled, porous plastic discs (9.5 mm in diameter, Part # 225&#x02013;388, SKC Inc., Eighty Four, PA, USA), and pressed into a recess in the impactor plate assembly. Nylon meshes (41&#x02013;<italic toggle="yes">&#x003bc;</italic>m net filters, Part # NY4104700, Carrigtwohill, Co. Cork, Ireland) held in place with a 47-mm filter holder were used to collect particles by Brownian motion in the diffusion stages. We used one mesh for the first diffusion stage, and six meshes for the second diffusion stage. The PACS was operated at 0.7 L min<sup>&#x02212;1</sup> for 8 h in each experiment.</p><p id="P17">The SMPS measured particle number concentration by size (64 size bins per decade) from ~10 to ~400 nm (equivalent mobility diameters) every 3 min during the first hour of sampling. The APS measured particle number concentration by size (32 size bins per decade) from ~700 nm to ~20 <italic toggle="yes">&#x003bc;</italic>m (aerodynamic diameters) every 30 s during the first hour of sampling. The nanoMOUDI was operated at 10 L min<sup>&#x02212;1</sup> for 8 h in each experiment, and 13 polycarbonate substrates (0.2 &#x003bc;m pore size, 47 mm in diameter, Part # PCT0247100, Sterlitech Corporation, Kent, WA, USA) coated with silicon oil, using the same procedure described above for preparing the PACS impactor substrates. A mixed cellulose esters filter (0.8 &#x003bc;m pore size, 47 mm in diameter, Part # FMCE847, Zefon International, Inc., Ocala, FL, USA) was used as a backup filter in the last nanoMOUDI stage to collect remaining particles.</p></sec><sec id="S5"><label>2.3.</label><title>Near-real-time aerosol size distributions</title><p id="P18">We applied the MMLN algorithm, presented by <xref rid="R5" ref-type="bibr">Cai et al. (2018)</xref>, to convert number and mass concentrations measured by stage with PACS to number, surface area and mass concentration by size. These particle size distributions measured with the PACS were compared to those measured with the SMPS/APS. We obtained three SMPS measurements (time = 3 min &#x000d7; 3 times = 9 min) during the first sampling hour, and then calculated the average of them. For the same 9-min time period, we also calculated the average of all APS measurements. After measuring the number concentration by size using SMPS and APS, we converted the number concentration by size to surface area and mass concentration by size by assuming the standard density and spheres of the particles. We compared the mean concentrations measured with the PACS and SMPS/APS during the same sampling time. For each metric, we then quantified the ability of PACS to measure aerosol size distributions with the following two statistical parameters:
<disp-formula id="FD7">
<label>(7)</label>
<mml:math id="M41" display="block"><mml:mi>P</mml:mi><mml:mi>e</mml:mi><mml:mi>r</mml:mi><mml:mi>c</mml:mi><mml:mi>e</mml:mi><mml:mi>n</mml:mi><mml:mi>t</mml:mi><mml:mi>a</mml:mi><mml:mi>g</mml:mi><mml:mi>e</mml:mi><mml:mspace width="0.25em"/><mml:mi>b</mml:mi><mml:mi>i</mml:mi><mml:mi>a</mml:mi><mml:mi>s</mml:mi><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:mo>&#x02211;</mml:mo><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mtext>PACS</mml:mtext></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mspace width="0.25em"/><mml:mo>-</mml:mo><mml:msub><mml:mrow><mml:mspace width="0.25em"/><mml:mtext>Ref</mml:mtext></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mo>&#x02211;</mml:mo><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:msub><mml:mrow><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfrac><mml:mo>&#x000d7;</mml:mo><mml:mn>100</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math>
</disp-formula>
<disp-formula id="FD8">
<label>(8)</label>
<mml:math id="M42" display="block"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>1</mml:mn><mml:mo>-</mml:mo><mml:mfrac><mml:mrow><mml:mrow><mml:mo stretchy="false">&#x02211;</mml:mo><mml:mrow><mml:mspace width="0.25em"/></mml:mrow></mml:mrow><mml:msup><mml:mrow><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:mi>P</mml:mi><mml:mi>A</mml:mi><mml:mi>C</mml:mi><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:mrow><mml:mrow><mml:mrow><mml:mo stretchy="false">&#x02211;</mml:mo><mml:mrow><mml:mspace width="0.25em"/></mml:mrow></mml:mrow><mml:msup><mml:mrow><mml:mfenced separators="|"><mml:mrow><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:msub><mml:mrow><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub><mml:mo>-</mml:mo><mml:mover accent="true"><mml:mrow><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:msub><mml:mrow><mml:mi>f</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:mrow><mml:mo>-</mml:mo></mml:mover></mml:mrow></mml:mfenced></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:mrow></mml:mfrac></mml:math>
</disp-formula>
where <inline-formula><mml:math id="M43" display="inline"><mml:mi>P</mml:mi><mml:mi>A</mml:mi><mml:mi>C</mml:mi><mml:msub><mml:mrow><mml:mi>S</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> and <inline-formula><mml:math id="M44" display="inline"><mml:msub><mml:mrow><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:mi>s</mml:mi></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> are the measured aerosol concentration with the PACS and the research instruments (SMPS/APS), respectively, for each size bin, <inline-formula><mml:math id="M45" display="inline"><mml:mi>j</mml:mi></mml:math></inline-formula>. <inline-formula><mml:math id="M46" display="inline"><mml:msub><mml:mrow><mml:mover accent="true"><mml:mrow><mml:mi>R</mml:mi><mml:mi>e</mml:mi><mml:mi>s</mml:mi></mml:mrow><mml:mo>-</mml:mo></mml:mover></mml:mrow><mml:mrow><mml:mi>j</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> is the averaged value over all size bins. To make the measurement results comparable between the PACS and SMPS/APS, we converted the aerodynamic diameter measured with the PACS for particles smaller than ~700 nm to equivalent mobility diameter by assuming standard density spheres (particle density = 1000 kg/m<sup>3</sup> and shape factor = 1).</p><p id="P19">Percentage bias indicates the tendency of the PACS to overestimate or underestimate the total concentration of each metric. <inline-formula><mml:math id="M47" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> indicates how well the aerosol size distributions of number, surface area and mass concentration measured with the PACS approximates the data points measured with the SMPS/APS.</p></sec><sec id="S6"><label>2.4.</label><title>Mass concentration by element and size</title><p id="P20">Loaded PACS and nanoMOUDI substrates were digested separately using a 1:4 mixture of 29 M hydrofluoric acid (HF, Trace Metal Grade, Fisher Scientific LLC, Pittsburgh, PA, USA) and 15 M nitric acid (HNO<sub>3</sub>, Trace Metal Grade, Fisher Scientific LLC, Pittsburgh, PA, USA) in 7-ml capsules (Perfluoroalkoxy vial, Savillex Corporation, MN, USA) on a hotplate at 95 &#x000b0;C for 24 h (<xref rid="R1" ref-type="bibr">Baker et al. 2004</xref>). After the lids were removed, HF and HNO<sub>3</sub> were evaporated from the samples. Then, 15 M HNO<sub>3</sub> was added into the capsules and the digestion was repeated with HNO<sub>3</sub> alone for another 12 h. After that the HNO<sub>3</sub> was evaporated, we diluted the samples with 2% HNO<sub>3</sub>.</p><p id="P21">Samples were analyzed for Mn, Fe, and Cu, by ICP-MS (X Series II quadrupole, Thermo Fisher Scientific, MA, USA), in CCT (collision cell technology) mode using a H<sub>2</sub>/He gas mixture for kinetic discrimination to minimize polyatomic interferences. A known amount of Co was added to each solution as an internal standard to correct for changes in sensitivity due to matrix supression and instrument drift. The internal standard and calibration solutions were National Institute of Standards and Technology (NIST) certified reference materials sold by Inorganic Ventures (Christiansburg, VA). Standard solutions were diluted with 2% HNO<sub>3</sub> (Trace Metal Grade, Fisher Scientific LLC, Pittsburgh, PA) to concentrations of 0, 10, 20, 30, 40, and 50 part per billion (ppb) that were used to determine a calibration curve for each mass (<sup>55</sup>Mn, <sup>57</sup>Fe, <sup>63</sup>Cu).</p><p id="P22">We compared the mass size distributions measured with the PACS to those measured with the nanoMOUDI for several particle compositions determined through ICP-MS. We ran the MMLN algorithm to obtain the needed inputs <inline-formula><mml:math id="M48" display="inline"><mml:mfenced close="" separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>M</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:mrow></mml:mfenced></mml:math></inline-formula>, <inline-formula><mml:math id="M49" display="inline"><mml:mi>M</mml:mi><mml:mi>M</mml:mi><mml:msub><mml:mrow><mml:mi>D</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula>, and <inline-formula><mml:math id="M50" display="inline"><mml:mfenced open="" separators="|"><mml:mrow><mml:mi>G</mml:mi><mml:mi>S</mml:mi><mml:msub><mml:mrow><mml:mi>D</mml:mi></mml:mrow><mml:mrow><mml:mi>i</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula> for the MDCS algorithm. Together with other inputs (<inline-formula><mml:math id="M51" display="inline"><mml:msub><mml:mrow><mml:mi>m</mml:mi></mml:mrow><mml:mrow><mml:mi>e</mml:mi><mml:mo>,</mml:mo><mml:mi>k</mml:mi><mml:mo>,</mml:mo><mml:mi>I</mml:mi><mml:mi>C</mml:mi><mml:mi>P</mml:mi></mml:mrow></mml:msub></mml:math></inline-formula> from ICP-MS and <inline-formula><mml:math id="M52" display="inline"><mml:msub><mml:mrow><mml:mi>C</mml:mi></mml:mrow><mml:mrow><mml:mi>k</mml:mi></mml:mrow></mml:msub><mml:mfenced separators="|"><mml:mrow><mml:msub><mml:mrow><mml:mi>d</mml:mi></mml:mrow><mml:mrow><mml:mi>p</mml:mi></mml:mrow></mml:msub></mml:mrow></mml:mfenced></mml:math></inline-formula> from measurement), we then ran the MDCS algorithm to calculate the mass concentrations by size for each element. Mn was used as an indicator of the ultrafine mode, and Cu was used as an indicator of the fine mode. Fe is one of the main elements in the Arizona road dust, so we used the Fe as an indicator of the coarse mode (<xref rid="R19" ref-type="bibr">Ramadan, Song, and Hopke 2000</xref>).</p></sec></sec><sec id="S7"><label>3.</label><title>Results and discussion</title><sec id="S8"><label>3.1.</label><title>Near-real-time aerosol size distributions</title><p id="P23">The near-real-time number, surface area and mass concentrations by size measured with the PACS and SMPS/APS are presented graphically for the three-mode aerosol in <xref rid="F3" ref-type="fig">Figure 3</xref> and for the two-mode aerosol in <xref rid="F4" ref-type="fig">Figure 4</xref>, and summarized in <xref rid="T1" ref-type="table">Table 1</xref>. In these figures, Panel a shows the raw concentration data from the PACS detectors (WCPC and photometer) relative to time, and Panel b shows the size distribution results from the MMLN algorithm compared to that from the SMPS/APS.</p><p id="P24">For the three-mode aerosol, the size selector in the PACS removed more particles with each stage added in a sequence of measurement, resulting in stair steps in the raw number and mass concentration (<xref rid="F3" ref-type="fig">Figure 3a</xref>). The number concentration was more stable than the mass concentration because the metal fume generated by the spark discharging system was more stable than the Arizona road dust generated by the fluidized bed aerosol generator. Particle number, surface area and mass concentrations by size measured with the PACS were compared to those measured with the SMPS/APS (<xref rid="F3" ref-type="fig">Figure 3b</xref>). The number concentration measured with the PACS was similar to that measured with the SMPS/APS (<italic toggle="yes">percentage bias</italic> for the total number concentration was 9.4%, coupled with <inline-formula><mml:math id="M53" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of 0.96 shown in <xref rid="T1" ref-type="table">Table 1</xref>). The surface area concentration was overestimated with a <italic toggle="yes">percentage bias</italic> of 17.8% and <inline-formula><mml:math id="M54" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of 0.77. The mass concentration measured with the PACS was 2.2% lower than that measured with the SMPS/APS with <inline-formula><mml:math id="M55" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> of 0.94.</p><p id="P25">For the two-mode aerosol, mass concentrations detected with the photometer were low (0.003 &#x000b1; 0.001 mg/m<sup>3</sup>) in all stages (<xref rid="F4" ref-type="fig">Figure 4a</xref>) because of the limitations of photometer for measuring mass concentrations. The photometer uses the Mie theory of light scattering of particles and the built-in optical parameters (e.g., light wavelength and detection angle) (<xref rid="R7" ref-type="bibr">G&#x000f6;rner, Bemer, and Fabries 1995</xref>). Therefore, the mass concentration measured with the photometer is a function of the main aerosol parameters including the refractive index, particle density, particle size, etc. For metal fume, <xref rid="R20" ref-type="bibr">Sousan et al. (2017)</xref> found that mass concentrations measured with a photometer were highly linear (correlation coefficient <inline-formula><mml:math id="M56" display="inline"><mml:mi mathvariant="normal">r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.99</mml:mn></mml:math></inline-formula>) with those measured gravimetrically, but were severely underestimated (slope of 0.2 &#x000b1; 0.01; photometer concentrations were five times lower than gravimetric mass concentrations). In addition, the photometer does not measure the mass concentration of ultrafine mode particles because the photometer only responds to particles larger than 100 nm (as reported by the manufacturer).</p><p id="P26">The size distributions measured with the PACS compared poorly to those from the SMPS/APS (<xref rid="F4" ref-type="fig">Figure 4b</xref>). For number concentration, the PACS underestimated the particle size of both ultrafine and fine modes. The inability to identify the ultrafine and fine modes resulted in underestimated total concentration and poor <inline-formula><mml:math id="M57" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:math></inline-formula> values for number (<inline-formula><mml:math id="M58" display="inline"><mml:mi mathvariant="normal">b</mml:mi><mml:mi mathvariant="normal">i</mml:mi><mml:mi mathvariant="normal">a</mml:mi><mml:mi mathvariant="normal">s</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn>17.7</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>; <inline-formula><mml:math id="M59" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.51</mml:mn></mml:math></inline-formula>), surface area (<inline-formula><mml:math id="M60" display="inline"><mml:mi mathvariant="normal">b</mml:mi><mml:mi mathvariant="normal">i</mml:mi><mml:mi mathvariant="normal">a</mml:mi><mml:mi mathvariant="normal">s</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn>45.5</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>; <inline-formula><mml:math id="M61" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0</mml:mn></mml:math></inline-formula>), and mass concentration (<inline-formula><mml:math id="M62" display="inline"><mml:mi mathvariant="normal">b</mml:mi><mml:mi mathvariant="normal">i</mml:mi><mml:mi mathvariant="normal">a</mml:mi><mml:mi mathvariant="normal">s</mml:mi><mml:mo>=</mml:mo><mml:mo>-</mml:mo><mml:mn>81.8</mml:mn><mml:mi mathvariant="normal">%</mml:mi></mml:math></inline-formula>; <inline-formula><mml:math id="M63" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup><mml:mo>=</mml:mo><mml:mn>0.08</mml:mn></mml:math></inline-formula>) (<xref rid="T1" ref-type="table">Table 1</xref>). We attribute this poor agreement to the inability of the photometer to measure particles throughout the fine mode. If we apply the correction factor of five for the metal fume obtained from the study of <xref rid="R20" ref-type="bibr">Sousan et al. (2017)</xref>, the size distributions measured with the PACS were greatly improved (<xref rid="SD1" ref-type="supplementary-material">Figure S1</xref>) shown in the <xref rid="SD1" ref-type="supplementary-material">online supplementary information</xref>. The bias of the number concentration was increased from &#x02212;17.7% to 31.8% with <italic toggle="yes">R</italic><sup><italic toggle="yes">2</italic></sup> increased from 0.51 to 0.76. The bias of the surface area concentration was increased from &#x02212;45.5% to 39.6% with <italic toggle="yes">R</italic><sup><italic toggle="yes">2</italic></sup> increased from 0 to 0.25. The bias of the mass concentration was increased from &#x02212;81.8% to &#x02212;10.6% with <italic toggle="yes">R</italic><sup><italic toggle="yes">2</italic></sup> increased from 0.08 to 0.77.</p><p id="P27">The PACS was able to fit aerosol size distributions for the three-mode aerosol substantially better than for the two-mode aerosol. As designed, reasonable size distributions for number, surface area, and mass concentration were obtained with the MMLN fitting algorithm when raw measurement data was available in all stages (i.e., the three-mode aerosol, <xref rid="F3" ref-type="fig">Figure 3</xref>). Thus, the PACS is able to successfully leverage the two-metric, low-resolution data from handheld CPC and photometer technology to estimate size distributions with high resolution over a wide size range in near-real-time.</p><p id="P28">We envision several ways to improve the ability of the PACS to measure near-real-time aerosol size distributions. For both three- and two-mode aerosols generated in this study, very little mass was detected by the photometer in diffusion stages due to the inability of the photometer to detect metal fume (<xref rid="F3" ref-type="fig">Figures 3a</xref> and <xref rid="F4" ref-type="fig">4a</xref>). The addition of a diffusion charger would provide a direct and highly sensitive way to measure ultrafine and fine particle surface area concentration of ultrafine and fine particles. However, adding a diffusion charger would increase the cost (~$15,000) and size of the device.</p><p id="P29">Adding a stage to the size selector may also help resolve the ultrafine and fine modes. Another impactor stage between impactor stage 2 (<italic toggle="yes">d</italic><sub><italic toggle="yes">50</italic></sub> of 400 nm) and 3 (<italic toggle="yes">d</italic><sub><italic toggle="yes">50</italic></sub> of 1 <italic toggle="yes">&#x003bc;</italic>m) may provide more information needed to better estimate the fine mode, whereas adding another diffusion stage after the diffusion stage with <italic toggle="yes">d</italic><sub><italic toggle="yes">50</italic></sub> of 56 nm may help with estimating both ultrafine and fine modes. However, adding stages would increase the measurement time, device size and device weight.</p></sec><sec id="S9"><label>3.2.</label><title>Mass concentration by element and size</title><p id="P30">The results of experiments to evaluate the ability of the PACS to measure mass concentration by element and size by comparing to nanoMOUDI are presented for the three-mode aerosol in <xref rid="F5" ref-type="fig">Figure 5</xref> and the two-mode aerosols in <xref rid="F6" ref-type="fig">Figure 6</xref>. In these figures, Panel a shows the raw and time-adjusted mass of the three elements selected to represent different aerosol modes measured on each PACS stage by ICP-MS chemical analysis. Since the valve is open and closed one by one, the time adjusted masses are higher than the raw determined masses, especially in the diffusion stages. The raw data are used as input to the PACS MDCS algorithm, and Panel b shows the mass size distribution output by the MDCS algorithm compared to that from the nanoMOUDI. The mass concentrations of the three elements measured with the PACS and the nanoMOUDI are summarized in <xref rid="T2" ref-type="table">Table 2</xref>.</p><p id="P31">For the three-mode aerosol, Fe, an indicator of coarse particles, was detected in impactor stages (<xref rid="F5" ref-type="fig">Figure 5a</xref>) but not in diffusion stages. We expected this result because the measured <italic toggle="yes">MMD</italic> of Arizona road dust is ~3.3 <italic toggle="yes">&#x003bc;</italic>m of aerodynamic diameter (<xref rid="F3" ref-type="fig">Figure 3b</xref>), which is consistent with the measurement from the study of <xref rid="R17" ref-type="bibr">Peters, Ott, and O&#x02019;Shaughnessy (2006)</xref>. The impactor stage with the <italic toggle="yes">d</italic><sub><italic toggle="yes">50</italic></sub> of 0.4 <italic toggle="yes">&#x003bc;</italic>m removed all dust particles. Also as expected based on SMPS/APS measurements (<xref rid="F3" ref-type="fig">Figure 3b</xref>), the marker for fine-mode particles, Cu, was detected in both diffusion stages, and the marker for ultrafine particles, Mn, was detected in the first diffusion stage. However, we were surprised that Cu and Mn were found at appreciable levels on the impactor stages. We discuss this finding during the presentation of results for the two-mode aerosol.</p><p id="P32">The mass concentrations of elements measured with the nanoMOUDI in the three modes shown in <xref rid="F5" ref-type="fig">Figure 5b</xref> were consistent with the time-adjusted masses of elements in PACS stages shown in <xref rid="F5" ref-type="fig">Figure 5a</xref>. For example, the Fe was only detected in impactor stages, so the coarse mode dominated the Fe mass concentration. Cu were mainly collected by the second diffusion stage, so the fine mode dominated the Cu mass concentration. Mn were determined in both impactor and diffusion stages, the Mn concentrations were found among all three modes. In addition, since the element masses estimated with the MDCS algorithm in the three modes were found in similar particle sizes compared to the <italic toggle="yes">d</italic><sub><italic toggle="yes">50s</italic></sub> of PACS stages, the mode selection process presented in the algorithm development was reasonable.</p><p id="P33">The PACS estimated the <italic toggle="yes">MMDs</italic> of the coarse mode well for all three elements, but overestimated the <italic toggle="yes">MMDs</italic> of the fine modes (<xref rid="F5" ref-type="fig">Figure 5b</xref>). However, according to <xref rid="T2" ref-type="table">Table 2</xref>, the Cu mass concentration in fine mode measured with the PACS (7.3 <italic toggle="yes">&#x003bc;</italic>g/m<sup>3</sup>) was similar to that measured with the nanoMOUDI (6.0 <italic toggle="yes">&#x003bc;</italic>g/m<sup>3</sup>). These results suggest that the <italic toggle="yes">MMD</italic> of the fine mode obtained from MMLN fitting results for the three-mode aerosol may not be applicable for each specific element. This finding is consistent with a previous study showing that particles of different composition usually have different modal structures (<xref rid="R2" ref-type="bibr">Bardouki et al. 2003</xref>). The PACS substantially underestimated the particles smaller than 10 nm. For the WCPC used in the PACS, the count efficiency of particles rapidly decreases from ~100% for 10-nm particles to ~0% for ~4-nm particles (<xref rid="R8" ref-type="bibr">Hakala et al. 2013</xref>). This may explain why the ultrafine mode measured with the PACS is consistent with that measured with the SMPS (<xref rid="F3" ref-type="fig">Figure 3b</xref>), but severely underestimated when compared to that measured with the nanoMOUDI (<xref rid="F5" ref-type="fig">Figure 5b</xref>).</p><p id="P34">For the two-mode aerosol, Fe was negligible because Arizona road dust was not present (<xref rid="F6" ref-type="fig">Figure 6a</xref>). As expected based on SMPS/APS measurements (<xref rid="F4" ref-type="fig">Figure 4b</xref>), Cu was mostly detected on Diffusion Stage 2, but also to a much lower extent in Impactor Stage 2 and Diffusion Stage 1. Interestingly, substantial quantities of Mn and Cu were collected on the impactor stages for the three-mode aerosol but not for the two-mode aerosol. We hypothesize that the metallic ultrafine and fine mode particles coagulated with the coarse-mode particles in the mixing and sampling zones of the chamber. The ultrafine and fine metal particles associated with larger particles were then collected on impactor plates of the PACS. We also considered losses due to diffusion, especially for ultrafine mode particles. However, the fact that Mn and Cu were present at substantially lower levels on the impactor stages for the two-mode aerosol than those for the three-mode aerosol suggests that diffusion is a minor mechanism of deposition on impactor plates.</p><p id="P35">The mass concentrations of elements measured with the nanoMOUDI in the three modes shown in <xref rid="F6" ref-type="fig">Figure 6b</xref> are consistent with the time-adjusted masses of elements in PACS stages shown in <xref rid="F6" ref-type="fig">Figure 6a</xref>. For example, Cu was mainly collected by the second diffusion stage, so the fine mode dominated the Cu mass concentration. Mn was measured in both impactor and diffusion stages, the Mn concentrations were found among all three modes. However, the element mass concentrations estimated with the MDCS algorithm were not inconsistent with nanoMOUDI or the <italic toggle="yes">d</italic><sub><italic toggle="yes">50s</italic></sub> of PACS stages.</p><p id="P36">Agreement between the mass size distributions from the PACS and nanoMOUDI was considerably poorer for the two-mode aerosol (<xref rid="F6" ref-type="fig">Figure 6b</xref>) than that for the three-mode aerosol (<xref rid="F5" ref-type="fig">Figure 5a</xref>). Similar to the three-mode aerosol, the PACS was unable to measure particles smaller than 10 nm. The PACS overestimated the Mn and Cu mass concentration of the ultrafine mode, but severely underestimate the Cu mass concentration of the fine mode (<xref rid="T2" ref-type="table">Table 2</xref>). Adding a backup filter as a last PACS stage might solve the issue of substantially overestimate/underestimate mass concentration for each element. With a backup filter, the PACS would be able to collect all size particles, so that conservation of mass could be used to distribute the mass of each element in each mode.</p><p id="P37">The accuracy of the fitting results from the MMLN algorithm greatly influenced the accuracy of the results from the MDCS algorithm. We used the <italic toggle="yes">MMD</italic> and <italic toggle="yes">GSD</italic> of each mode obtained from the MMLN fitting results to distribute the mass concentration of the aerosol composition in each mode. For the three-mode aerosol, the algorithm overestimated the number concentration and the <italic toggle="yes">CMD</italic> of the fine mode (<xref rid="F3" ref-type="fig">Figure 3b</xref>); consequently, the PACS overestimated the mass concentration and the <italic toggle="yes">MMD</italic> of the fine mode as well (<xref rid="F5" ref-type="fig">Figure 5b</xref> and <xref rid="T2" ref-type="table">Table 2</xref>). For the two-mode aerosol, the MMLN algorithm underestimated the <italic toggle="yes">CMD</italic> of the fine mode (<xref rid="F4" ref-type="fig">Figure 4b</xref>), therefore, compared to the nanoMOUDI, the PACS substantially underestimated mass concentration of the fine mode (<xref rid="F6" ref-type="fig">Figure 6b</xref> and <xref rid="T2" ref-type="table">Table 2</xref>).</p><p id="P38">The results from the MDCS algorithm were also affected by some assumptions made in the algorithm inputs. For example, we used non-chemical specific data on modes from the MMLN algorithm results to distribute the element mass data (Input 3). This assumption may explain the difference observed between the measurements from the PACS and nanoMOUDI because particles of different composition usually have various modal structures (<xref rid="R2" ref-type="bibr">Bardouki et al. 2003</xref>). In addition, when we calculated the mass percentage of each mode (<xref rid="FD4" ref-type="disp-formula">Equation (4)</xref>) and the mass percentage of particles collected by each stage (<xref rid="FD5" ref-type="disp-formula">Equation (5)</xref>), we assumed standard density and spherical shape of all particles in the calculation. Furthermore, converting the equivalent mobility diameter measured with the PACS for particles smaller than ~700 nm to the aerodynamic diameter was also based on the assumption of standard density spheres, which is the same as the assumption used to convert the number concentration by size measured with SMPS to surface area and mass concentration by size. However, the particle density and shape factor might be different for various aerosol types. This may be why the size distributions measured with the PACS were consistent with those measured with the SMPS/APS, but not consistent with those measured with nanoMOUDI.</p><p id="P39">We envision several ways to improve the ability of the PACS to resolve mass size distributions by composition and size in the future. First, the MDCS algorithm is dependent on the accuracy of the fitting results from the MMLN algorithm. The MMLN algorithm could be improved by applying a detector (e.g., diffusion charger) more sensitive to ultrafine mode particles and by adding impactor/diffusion stages. Knowing the modal structure by composition might improve the MDCS algorithm results. We could measure the particle size distribution by composition using the nanoMOUDI, so that we could apply the measured modal structure by composition to the MDCS algorithm. In addition, after collecting particles, we can analyze the particles physically and chemically to have more reasonable assumptions of the particle density and shape factor. By knowing the particle density and shape factor could improve the MMLN fitting results as well as presented by <xref rid="R5" ref-type="bibr">Cai et al. (2018)</xref>.</p><p id="P40">Limitations of the study include the potential that the laboratory generated multi-mode aerosols are not representative of real multi-mode aerosols in the occupational and environmental settings. In this study, we only generated fresh Mn fume and aged Cu fume for the ultrafine and fine mode particles, respectively. Many other metal and nonmetal aerosol types are needed to be tested. A field study would allow for a practical assessment of the PACS, including set up and durability, and performance of analytical methods in a &#x02018;real-world&#x02019; environment.</p></sec></sec><sec id="S10"><label>4.</label><title>Conclusion</title><p id="P41">In laboratory tests, we demonstrated the feasibility of measuring the size distributions of multi-modal aerosols with the PACS. For a three-mode aerosol, the near-real-time number, surface area and mass concentrations by size measured with the newly-developed PACS agreed well with those from the SMPS/APS. The mass concentration by element and size estimated with the PACS compared well to those measured with the nanoMOUDI for the coarse mode of all elements, but less so for ultrafine and fine modes. Results were considerably poorer for the two-mode aerosol, especially for near-real-time surface area and mass concentrations by size. Although promising, the PACS in its current form has insufficient accuracy to replace the SMPS/APS. However, the deviation of the PACS from SMPS/APS does not entirely reflect the bias of the PACS due to the assumptions (spherical particle with standard density) used in this study. For example, the surface area estimated in this study is geometric surface area assuming each particle is spherical. However, each instrument used in the comparison measures different equivalent size (mobility for SMPS, aerodynamic for APS, and diffusion for the PACS diffusion stages), and none of these are geometric size. The testing particles generated using spark discharge are highly agglomerated (non-sphere). Therefore, the measurements from these instruments are expected to be different. In the future, applying spherical nanoparticles as testing aerosol might be better than using the agglomerated nanoparticles generated by spark discharge. Future work will also explore ways to improve accuracy through hardware modifications, improvements to the MMLN algorithm, and making reasonable assumptions of particle density, shape factor and modal structure by composition.</p></sec><sec sec-type="supplementary-material" id="SM1"><title>Supplementary Material</title><supplementary-material id="SD1" position="float" content-type="local-data"><label>Supplementary Material</label><media xlink:href="NIHMS1923255-supplement-Supplementary_Material.docx" id="d64e2225" position="anchor"/></supplementary-material></sec></body><back><ack id="S11"><title>Acknowledgments</title><p id="P42">The authors would like to express their appreciation to Dr. Beau Farmer of TSI for providing the photometer and technical support. We would also like to thank Dr. Susanne V. Hering of Aerosol Dynamics for providing the WCPC and technical support.</p><sec id="S12"><title>Funding</title><p id="P43">This work was supported by a small-business innovative research (SBIR) project (AF131-024) funded by the U.S. Air Force and a pilot project (No. T42OH008491) funded by the Heartland Center for Occupational Health &#x00026; Safety.</p></sec></ack><fn-group><fn id="FN3"><p id="P44"><xref rid="SD1" ref-type="supplementary-material">Supplemental data</xref> for this article is available online at on the publisher&#x02019;s website.</p></fn></fn-group><ref-list><title>Reference</title><ref id="R1"><mixed-citation publication-type="journal"><name><surname>Baker</surname><given-names>J</given-names></name>, <name><surname>Peate</surname><given-names>D</given-names></name>, <name><surname>Waight</surname><given-names>T</given-names></name>, and <name><surname>Meyzen</surname><given-names>C</given-names></name>. <year>2004</year>. <article-title>Pb isotopic analysis of standards and samples using a 207 Pb&#x02013;204 Pb double spike and thallium to correct for mass bias with a double-focusing MC-ICP-MS</article-title>. <source>Chem. Geol</source>. <volume>211</volume> (<issue>3&#x02013;4</issue>):<fpage>275</fpage>&#x02013;<lpage>303</lpage>. doi:<pub-id pub-id-type="doi">10.1016/j.chemgeo.2004.06.030</pub-id>.</mixed-citation></ref><ref id="R2"><mixed-citation publication-type="journal"><name><surname>Bardouki</surname><given-names>H</given-names></name>, <name><surname>Liakakou</surname><given-names>H</given-names></name>, <name><surname>Economou</surname><given-names>C</given-names></name>, <name><surname>Sciare</surname><given-names>J</given-names></name>, <name><surname>Smol&#x000ed;k</surname><given-names>J</given-names></name>, <name><surname>&#x0017d;d&#x000ed;mal</surname><given-names>V</given-names></name>, <name><surname>Eleftheriadis</surname><given-names>K</given-names></name>, <name><surname>Lazaridis</surname><given-names>M</given-names></name>, <name><surname>Dye</surname><given-names>C</given-names></name>, and <name><surname>Mihalopoulos</surname><given-names>N</given-names></name>. <year>2003</year>. <article-title>Chemical composition of size-resolved atmospheric aerosols in the Eastern Mediterranean during summer and winter</article-title>. <source>Atmos. Environ</source>. <volume>37</volume> (<issue>2</issue>):<fpage>195</fpage>&#x02013;<lpage>208</lpage>. doi:<pub-id pub-id-type="doi">10.1016/S1352-2310(02)00859-2.</pub-id></mixed-citation></ref><ref id="R3"><mixed-citation publication-type="journal"><name><surname>Baron</surname><given-names>PA</given-names></name>
<year>1986</year>. <article-title>Calibration and use of the aerodynamic particle sizer (APS 3300)</article-title>. <source>Aerosol Sci. Technol</source>. <volume>5</volume> (<issue>1</issue>):<fpage>55</fpage>&#x02013;<lpage>67</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786828608959076</pub-id>.</mixed-citation></ref><ref id="R4"><mixed-citation publication-type="journal"><name><surname>Brouwer</surname><given-names>DH</given-names></name>, <name><surname>Gijsbers</surname><given-names>JH</given-names></name>, and <name><surname>Lurvink</surname><given-names>MW</given-names></name>. <year>2004</year>. <article-title>Personal exposure to ultrafine particles in the workplace: Exploring sampling techniques and strategies</article-title>. <source>Ann. Occup. Hyg</source>. <volume>48</volume> (<issue>5</issue>):<fpage>439</fpage>&#x02013;<lpage>453</lpage>. doi:<pub-id pub-id-type="doi">10.1093/annhyg/meh040</pub-id>.<pub-id pub-id-type="pmid">15240340</pub-id></mixed-citation></ref><ref id="R5"><mixed-citation publication-type="journal"><name><surname>Cai</surname><given-names>C</given-names></name>, <name><surname>Thomas</surname><given-names>GW</given-names></name>, <name><surname>Yang</surname><given-names>T</given-names></name>, <name><surname>Park</surname><given-names>JH</given-names></name>, <name><surname>Gogineni</surname><given-names>SP</given-names></name>, and <name><surname>Peters</surname><given-names>TM</given-names></name>. <year>2018</year>. <article-title>Development of a portable aerosol collector and spectrometer (PACS)</article-title>. <source>Aerosol Sci. Technol</source>. <volume>52</volume> (<issue>12</issue>):<fpage>1351</fpage>&#x02013;<lpage>1369</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786826.2018.1524985</pub-id>.<pub-id pub-id-type="pmid">37654799</pub-id></mixed-citation></ref><ref id="R6"><mixed-citation publication-type="book"><name><surname>Ellenbecker</surname><given-names>MJ</given-names></name>, and <name><surname>Tsai</surname><given-names>CSJ</given-names></name>. <year>2015</year>. <source>Exposure assessment and safety considerations for working with engineered nanoparticles</source>. <publisher-loc>Hoboken, NJ</publisher-loc>: <publisher-name>John Wiley &#x00026; Sons</publisher-name>.</mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>G&#x000f6;rner</surname><given-names>P</given-names></name>, <name><surname>Bemer</surname><given-names>D</given-names></name>, and <name><surname>Fabries</surname><given-names>JF</given-names></name>. <year>1995</year>. <article-title>Photometer measurement of polydisperse aerosols</article-title>. <source>J. Aerosol Sci</source>. <volume>26</volume> (<issue>8</issue>):<fpage>1281</fpage>&#x02013;<lpage>1302</lpage>. doi:<pub-id pub-id-type="doi">10.1016/0021-8502(95)00049-6</pub-id>.</mixed-citation></ref><ref id="R8"><mixed-citation publication-type="journal"><name><surname>Hakala</surname><given-names>J</given-names></name>, <name><surname>Manninen</surname><given-names>HE</given-names></name>, <name><surname>Pet&#x000e4;j&#x000e4;</surname><given-names>T</given-names></name>, and <name><surname>Sipil&#x000e4;</surname><given-names>M</given-names></name>. <year>2013</year>. <article-title>Counting efficiency of a TSI environmental particle counter monitor model 3783</article-title>. <source>Aerosol Sci. Technol</source>. <volume>47</volume> (<issue>5</issue>):<fpage>482</fpage>&#x02013;<lpage>487</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786826.2013.766666</pub-id>.</mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Harrison</surname><given-names>RM</given-names></name>, and <name><surname>Yin</surname><given-names>J</given-names></name>. <year>2000</year>. <article-title>Particulate matter in the atmosphere: Which particle properties are important for its effects on health?</article-title>
<source>Sci. Total Environ</source>. <volume>249</volume> (<issue>1&#x02013;3</issue>):<fpage>85</fpage>&#x02013;<lpage>101</lpage>.<pub-id pub-id-type="pmid">10813449</pub-id></mixed-citation></ref><ref id="R10"><mixed-citation publication-type="book"><name><surname>Hinds</surname><given-names>WC</given-names></name>
<year>1999</year>. <source>Aerosol technology: Properties, behavior, and measurement of airborne particles</source>. <publisher-name>John Wiley &#x00026; Sons</publisher-name>.</mixed-citation></ref><ref id="R11"><mixed-citation publication-type="journal"><name><surname>Karthikeyan</surname><given-names>S</given-names></name>, <name><surname>Joshi</surname><given-names>UM</given-names></name>, and <name><surname>Balasubramanian</surname><given-names>R</given-names></name>. <year>2006</year>. <article-title>Microwave assisted sample preparation for determining water-soluble fraction of trace elements in urban airborne particulate matter: Evaluation of bioavailability</article-title>. <source>Anal. Chim. Acta</source>
<volume>576</volume> (<issue>1</issue>):<fpage>23</fpage>&#x02013;<lpage>30</lpage>. doi:<pub-id pub-id-type="doi">10.1016/j.aca.2006.05.051</pub-id>.<pub-id pub-id-type="pmid">17723609</pub-id></mixed-citation></ref><ref id="R12"><mixed-citation publication-type="journal"><name><surname>Kittelson</surname><given-names>DB</given-names></name>
<year>1998</year>. <article-title>Engines and nanoparticles: A review</article-title>. <source>J. Aerosol Sci</source>. <volume>29</volume> (<issue>5&#x02013;6</issue>):<fpage>575</fpage>&#x02013;<lpage>588</lpage>. doi:<pub-id pub-id-type="doi">10.1016/S0021-8502(97)10037-4</pub-id>.</mixed-citation></ref><ref id="R13"><mixed-citation publication-type="journal"><name><surname>Kulkarni</surname><given-names>P</given-names></name>, <name><surname>Chellam</surname><given-names>S</given-names></name>, <name><surname>Flanagan</surname><given-names>JB</given-names></name>, and <name><surname>Jayanty</surname><given-names>RKM</given-names></name>. <year>2007</year>. <article-title>Microwave digestion&#x02014;ICP-MS for elemental analysis in ambient airborne fine particulate matter: Rare earth elements and validation using a filter borne fine particle certified reference material</article-title>. <source>Anal. Chim. Acta</source>
<volume>599</volume> (<issue>2</issue>):<fpage>170</fpage>&#x02013;<lpage>176</lpage>. doi:<pub-id pub-id-type="doi">10.1016/j.aca.2007.08.014</pub-id>.<pub-id pub-id-type="pmid">17870279</pub-id></mixed-citation></ref><ref id="R14"><mixed-citation publication-type="journal"><name><surname>Marple</surname><given-names>VA</given-names></name>, <name><surname>Rubow</surname><given-names>KL</given-names></name>, and <name><surname>Behm</surname><given-names>SM</given-names></name>. <year>1991</year>. <article-title>A microorifice uniform deposit impactor (MOUDI): description, calibration, and use</article-title>. <source>Aerosol Sci. Technol</source>. <volume>14</volume> (<issue>4</issue>):<fpage>434</fpage>&#x02013;<lpage>446</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786829108959504</pub-id>.</mixed-citation></ref><ref id="R15"><mixed-citation publication-type="journal"><name><surname>Pak</surname><given-names>SS</given-names></name>, <name><surname>Liu</surname><given-names>BY</given-names></name>, and <name><surname>Rubow</surname><given-names>KL</given-names></name>. <year>1992</year>. <article-title>Effect of coating thickness on particle bounce in inertial impactors</article-title>. <source>Aerosol Sci. Technol</source>. <volume>16</volume> (<issue>3</issue>):<fpage>141</fpage>&#x02013;<lpage>150</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786829208959544</pub-id>.</mixed-citation></ref><ref id="R16"><mixed-citation publication-type="journal"><name><surname>Park</surname><given-names>JH</given-names></name>, <name><surname>Mudunkotuwa</surname><given-names>IA</given-names></name>, <name><surname>Kim</surname><given-names>JS</given-names></name>, <name><surname>Stanam</surname><given-names>A</given-names></name>, <name><surname>Thorne</surname><given-names>PS</given-names></name>, <name><surname>Grassian</surname><given-names>VH</given-names></name>, and <name><surname>Peters</surname><given-names>TM</given-names></name>. <year>2014</year>. <article-title>Physicochemical characterization of simulated welding fumes from a spark discharge system</article-title>. <source>Aerosol Sci. Technol</source>. <volume>48</volume> (<issue>7</issue>):<fpage>768</fpage>&#x02013;<lpage>776</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786826.2014.925536</pub-id>.</mixed-citation></ref><ref id="R17"><mixed-citation publication-type="journal"><name><surname>Peters</surname><given-names>TM</given-names></name>, <name><surname>Ott</surname><given-names>D</given-names></name>, and <name><surname>O&#x02019;Shaughnessy</surname><given-names>PT</given-names></name>. <year>2006</year>. <article-title>Comparison of the Grimm 1.108 and 1.109 portable aerosol spectrometer to the TSI 3321 aerodynamic particle sizer for dry particles</article-title>. <source>Ann. Occup. Hyg</source>. <volume>50</volume> (<issue>8</issue>):<fpage>843</fpage>&#x02013;<lpage>850</lpage>. doi:<pub-id pub-id-type="doi">10.1093/annhyg/mel067</pub-id>.<pub-id pub-id-type="pmid">17041244</pub-id></mixed-citation></ref><ref id="R18"><mixed-citation publication-type="journal"><name><surname>Ramachandran</surname><given-names>G</given-names></name>, <name><surname>Paulsen</surname><given-names>D</given-names></name>, <name><surname>Watts</surname><given-names>W</given-names></name>, and <name><surname>Kittelson</surname><given-names>D</given-names></name>. <year>2005</year>. <article-title>Mass, surface area and number metrics in diesel occupational exposure assessment</article-title>. <source>J. Environ. Monit</source>. <volume>7</volume> (<issue>7</issue>):<fpage>728</fpage>&#x02013;<lpage>735</lpage>. doi:<pub-id pub-id-type="doi">10.1039/b503854e</pub-id>.<pub-id pub-id-type="pmid">15986054</pub-id></mixed-citation></ref><ref id="R19"><mixed-citation publication-type="journal"><name><surname>Ramadan</surname><given-names>Z</given-names></name>, <name><surname>Song</surname><given-names>XH</given-names></name>, and <name><surname>Hopke</surname><given-names>PK</given-names></name>. <year>2000</year>. <article-title>Identification of sources of phoenix aerosol by positive matrix factorization</article-title>. <source>J. Air Waste Manage. Assoc</source>. <volume>50</volume> (<issue>8</issue>):<fpage>1308</fpage>&#x02013;<lpage>1320</lpage>.</mixed-citation></ref><ref id="R20"><mixed-citation publication-type="journal"><name><surname>Sousan</surname><given-names>S</given-names></name>, <name><surname>Koehler</surname><given-names>K</given-names></name>, <name><surname>Hallett</surname><given-names>L</given-names></name>, and <name><surname>Peters</surname><given-names>TM</given-names></name>. <year>2017</year>. <article-title>Evaluation of consumer monitors to measure particulate matter</article-title>. <source>J. Aerosol Sci</source>. <volume>107</volume>:<fpage>123</fpage>&#x02013;<lpage>133</lpage>. doi:<pub-id pub-id-type="doi">10.1016/j.jaerosci.2017.02.013</pub-id>.<pub-id pub-id-type="pmid">28871212</pub-id></mixed-citation></ref><ref id="R21"><mixed-citation publication-type="journal"><name><surname>Valavanidis</surname><given-names>A</given-names></name>, <name><surname>Fiotakis</surname><given-names>K</given-names></name>, and <name><surname>Vlachogianni</surname><given-names>T</given-names></name>. <year>2008</year>. <article-title>Airborne particulate matter and human health: Toxicological assessment and importance of size and composition of particles for oxidative damage and carcinogenic mechanisms</article-title>. <source>J. Environ. Sci. Health Part C</source>
<volume>26</volume> (<issue>4</issue>):<fpage>339</fpage>&#x02013;<lpage>362</lpage>. doi:<pub-id pub-id-type="doi">10.1080/10590500802494538</pub-id>.</mixed-citation></ref><ref id="R22"><mixed-citation publication-type="journal"><name><surname>Wang</surname><given-names>SC</given-names></name>, and <name><surname>Flagan</surname><given-names>RC</given-names></name>. <year>1990</year>. <article-title>Scanning electrical mobility spectrometer</article-title>. <source>Aerosol Sci. Technol</source>. <volume>13</volume> (<issue>2</issue>):<fpage>230</fpage>&#x02013;<lpage>240</lpage>. doi:<pub-id pub-id-type="doi">10.1080/02786829008959441</pub-id>.</mixed-citation></ref><ref id="R23"><mixed-citation publication-type="journal"><name><surname>Whitby</surname><given-names>KT</given-names></name>, and <name><surname>Sverdrup</surname><given-names>GM</given-names></name>. <year>1980</year>. <article-title>California aerosols-their physical and chemical characteristics</article-title>. <source>Adv. Environ. Sci. Technol</source>. <volume>9</volume>:<fpage>477</fpage>&#x02013;<lpage>525</lpage>.</mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Figure 1.</label><caption><p id="P45">Flow chart of the mass distribution by composition and size (MDCS) algorithm to estimate mass size distributions by particle compositions.</p></caption><graphic xlink:href="nihms-1923255-f0001" position="float"/></fig><fig position="float" id="F2"><label>Figure 2.</label><caption><p id="P46">Experimental set-up used to compare particle size distributions measured with the PACS to those measured with SMPS, APS, and Nano-MOUDI.</p></caption><graphic xlink:href="nihms-1923255-f0002" position="float"/></fig><fig position="float" id="F3"><label>Figure 3.</label><caption><p id="P47">Near-real-time number, surface area, and mass concentration by size measured with the PACS compared to the SMPS/APS for the three-mode aerosol: (a) raw input to the multi-modal log-normal (MMLN) algorithm from the WCPC and photometer (stage d<sub>50</sub> provided in parentheses), and (b) output size distributions from the algorithm. Error bars represent the standard deviation of three measurements during the 1st hour experiment.</p></caption><graphic xlink:href="nihms-1923255-f0003" position="float"/></fig><fig position="float" id="F4"><label>Figure 4.</label><caption><p id="P48">Near-real-time number, surface area, and mass concentration by size measured with the PACS compared to the SMPS/APS for the two-mode aerosol: (a) raw input to the multi-modal log-normal (MMLN) algorithm from the WCPC and photometer (stage d<sub>50</sub> provided in parentheses), and (b) output size distributions from the algorithm. Error bars represent the standard deviation of three measurements during the 1st hour experiment.</p></caption><graphic xlink:href="nihms-1923255-f0004" position="float"/></fig><fig position="float" id="F5"><label>Figure 5.</label><caption><p id="P49">Mass concentration by size and composition measured with the PACS compared to the nanoMOUDI for the three-mode aerosol: (a) raw and adjusted input to the mass distribution by composition and size (MDCS) algorithm from ICP-MS (stage d<sub>50</sub> provided in parentheses), and (b) output size distributions from the algorithm output. Error bars represent the standard deviation of three measurements.</p></caption><graphic xlink:href="nihms-1923255-f0005" position="float"/></fig><fig position="float" id="F6"><label>Figure 6.</label><caption><p id="P50">Mass concentration by size and composition measured with the PACS compared to the nanoMOUDI for the two-mode aerosol: (a) raw and adjusted input to the mass distribution by composition and size (MDCS) algorithm from ICP-MS (stage d<sub>50</sub> provided in parentheses), and (b) output size distributions from the algorithm output. Error bars represent the standard deviation of three measurements.</p></caption><graphic xlink:href="nihms-1923255-f0006" position="float"/></fig><table-wrap position="float" id="T1" orientation="landscape"><label>Table 1.</label><caption><p id="P51">Near-real-time particle size distributions measured with the PACS compared to the SMPS/APS.</p></caption><table frame="hsides" rules="none"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="bottom" rowspan="1" colspan="1">Number of modes</th><th align="center" valign="bottom" rowspan="1" colspan="1">Concentration</th><th align="center" valign="bottom" rowspan="1" colspan="1">Measurement PACS</th><th align="center" valign="bottom" rowspan="1" colspan="1">SMPS/APS</th><th align="center" valign="bottom" rowspan="1" colspan="1">Percentage bias, %</th><th align="center" valign="bottom" rowspan="1" colspan="1">
<inline-formula>
<mml:math id="M64" display="inline"><mml:msup><mml:mrow><mml:mi>R</mml:mi></mml:mrow><mml:mrow><mml:mn>2</mml:mn></mml:mrow></mml:msup></mml:math>
</inline-formula>
</th></tr><tr><th colspan="6" align="left" valign="bottom" rowspan="1">
<hr/>
</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Three</td><td align="left" valign="top" rowspan="1" colspan="1">Number, particles/cm<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">2.7 &#x000d7; 10<sup>5</sup></td><td align="center" valign="top" rowspan="1" colspan="1">2.4 &#x000d7; 10<sup>5</sup></td><td align="center" valign="top" rowspan="1" colspan="1">14.2</td><td align="center" valign="top" rowspan="1" colspan="1">0.97</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="top" rowspan="1" colspan="1">Surface area, <italic toggle="yes">&#x003bc;</italic>m<sup>2</sup>/cm<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">4.5 &#x000d7; 10<sup>9</sup></td><td align="center" valign="top" rowspan="1" colspan="1">4.3 &#x000d7; 10<sup>9</sup></td><td align="center" valign="top" rowspan="1" colspan="1">20.9</td><td align="center" valign="top" rowspan="1" colspan="1">0.64</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="top" rowspan="1" colspan="1">Mass, <italic toggle="yes">&#x003bc;</italic>g/m<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">1.6 &#x000d7; 10<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">1.9 &#x000d7; 10<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;11.1</td><td align="center" valign="top" rowspan="1" colspan="1">0.84</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Two</td><td align="left" valign="top" rowspan="1" colspan="1">Number, particles/cm<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">2.7 &#x000d7; 10<sup>5</sup></td><td align="center" valign="top" rowspan="1" colspan="1">2.2 &#x000d7; 10<sup>5</sup></td><td align="center" valign="top" rowspan="1" colspan="1">24.0</td><td align="center" valign="top" rowspan="1" colspan="1">0.90</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="top" rowspan="1" colspan="1">Surface area, <italic toggle="yes">&#x003bc;</italic>m<sup>2</sup>/cm<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">6.6 &#x000d7; 10<sup>8</sup></td><td align="center" valign="top" rowspan="1" colspan="1">7.2 &#x000d7; 10<sup>8</sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;7.8</td><td align="center" valign="top" rowspan="1" colspan="1">0.08</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="top" rowspan="1" colspan="1">Mass, <italic toggle="yes">&#x003bc;</italic>g/m<sup>3</sup></td><td align="center" valign="top" rowspan="1" colspan="1">4.5 &#x000d7; 10<sup>0</sup></td><td align="center" valign="top" rowspan="1" colspan="1">1.6 &#x000d7; 10<sup>1</sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02212;71.8</td><td align="center" valign="top" rowspan="1" colspan="1">0.09</td></tr></tbody></table></table-wrap><table-wrap position="float" id="T2" orientation="landscape"><label>Table 2.</label><caption><p id="P52">Mass concentrations of various elements in each mode measured with the PACS and nanoMOUDI</p></caption><table frame="hsides" rules="none"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th rowspan="2" align="left" valign="bottom" colspan="1">Number of modes</th><th rowspan="2" align="left" valign="bottom" colspan="1">Device</th><th colspan="4" align="center" valign="top" rowspan="1">Mn, &#x003bc;g/m<sup>3</sup><hr/></th><th colspan="4" align="center" valign="top" rowspan="1">Cu, &#x003bc;g/m<sup>3</sup><hr/></th><th colspan="4" align="center" valign="top" rowspan="1">Fe, &#x003bc;g/m<sup>3</sup><hr/></th></tr><tr><th align="center" valign="top" rowspan="1" colspan="1">ultrafine</th><th align="center" valign="top" rowspan="1" colspan="1">fine</th><th align="center" valign="top" rowspan="1" colspan="1">coarse</th><th align="center" valign="top" rowspan="1" colspan="1">total</th><th align="center" valign="top" rowspan="1" colspan="1">ultrafine</th><th align="center" valign="top" rowspan="1" colspan="1">fine</th><th align="center" valign="top" rowspan="1" colspan="1">coarse</th><th align="center" valign="top" rowspan="1" colspan="1">total</th><th align="center" valign="top" rowspan="1" colspan="1">ultrafine</th><th align="center" valign="top" rowspan="1" colspan="1">fine</th><th align="center" valign="top" rowspan="1" colspan="1">coarse</th><th align="center" valign="top" rowspan="1" colspan="1">total</th></tr><tr><th colspan="14" align="center" valign="top" rowspan="1">
<hr/>
</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Three</td><td align="left" valign="top" rowspan="1" colspan="1">PACS</td><td align="center" valign="top" rowspan="1" colspan="1">1.14</td><td align="center" valign="top" rowspan="1" colspan="1">4.09</td><td align="center" valign="top" rowspan="1" colspan="1">2.49</td><td align="center" valign="top" rowspan="1" colspan="1">6.58</td><td align="center" valign="top" rowspan="1" colspan="1">0.44</td><td align="center" valign="top" rowspan="1" colspan="1">19.38</td><td align="center" valign="top" rowspan="1" colspan="1">0.43</td><td align="center" valign="top" rowspan="1" colspan="1">20.25</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td><td align="center" valign="top" rowspan="1" colspan="1">1.47</td><td align="center" valign="top" rowspan="1" colspan="1">47.61</td><td align="center" valign="top" rowspan="1" colspan="1">49.08</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="top" rowspan="1" colspan="1">Nano_MOUDI</td><td align="center" valign="top" rowspan="1" colspan="1">0.93</td><td align="center" valign="top" rowspan="1" colspan="1">1.39</td><td align="center" valign="top" rowspan="1" colspan="1">1.83</td><td align="center" valign="top" rowspan="1" colspan="1">4.15</td><td align="center" valign="top" rowspan="1" colspan="1">0.11</td><td align="center" valign="top" rowspan="1" colspan="1">5.96</td><td align="center" valign="top" rowspan="1" colspan="1">0.38</td><td align="center" valign="top" rowspan="1" colspan="1">6.45</td><td align="center" valign="top" rowspan="1" colspan="1">0.01</td><td align="center" valign="top" rowspan="1" colspan="1">7.93</td><td align="center" valign="top" rowspan="1" colspan="1">71.33</td><td align="center" valign="top" rowspan="1" colspan="1">79.27</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Two</td><td align="left" valign="top" rowspan="1" colspan="1">PACS</td><td align="center" valign="top" rowspan="1" colspan="1">2.56</td><td align="center" valign="top" rowspan="1" colspan="1">0.40</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td><td align="center" valign="top" rowspan="1" colspan="1">2.96</td><td align="center" valign="top" rowspan="1" colspan="1">0.84</td><td align="center" valign="top" rowspan="1" colspan="1">0.13</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td><td align="center" valign="top" rowspan="1" colspan="1">0.97</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td><td align="center" valign="top" rowspan="1" colspan="1">0.00</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1"/><td align="left" valign="top" rowspan="1" colspan="1">Nano_MOUDI</td><td align="center" valign="top" rowspan="1" colspan="1">0.42</td><td align="center" valign="top" rowspan="1" colspan="1">0.27</td><td align="center" valign="top" rowspan="1" colspan="1">0.07</td><td align="center" valign="top" rowspan="1" colspan="1">0.76</td><td align="center" valign="top" rowspan="1" colspan="1">0.02</td><td align="center" valign="top" rowspan="1" colspan="1">8.44</td><td align="center" valign="top" rowspan="1" colspan="1">0.11</td><td align="center" valign="top" rowspan="1" colspan="1">8.57</td><td align="center" valign="top" rowspan="1" colspan="1">0.34</td><td align="center" valign="top" rowspan="1" colspan="1">0.08</td><td align="center" valign="top" rowspan="1" colspan="1">0.30</td><td align="center" valign="top" rowspan="1" colspan="1">0.72</td></tr></tbody></table></table-wrap></floats-group></article>