<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101669031</journal-id><journal-id journal-id-type="pubmed-jr-id">44389</journal-id><journal-id journal-id-type="nlm-ta">ACS Sens</journal-id><journal-id journal-id-type="iso-abbrev">ACS Sens</journal-id><journal-title-group><journal-title>ACS sensors</journal-title></journal-title-group><issn pub-type="epub">2379-3694</issn></journal-meta><article-meta><article-id pub-id-type="pmid">28967741</article-id><article-id pub-id-type="pmc">10083731</article-id><article-id pub-id-type="doi">10.1021/acssensors.7b00396</article-id><article-id pub-id-type="manuscript">HHSPA1880413</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Development of an Inexpensive RGB Color Sensor for the Detection of Hydrogen Cyanide Gas</article-title></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="false">http://orcid.org/0000-0002-7953-4659</contrib-id><name><surname>Greenawald</surname><given-names>Lee A.</given-names></name><xref rid="CR1" ref-type="corresp">*</xref><xref rid="A1" ref-type="aff">&#x02020;</xref></contrib><contrib contrib-type="author"><name><surname>Boss</surname><given-names>Gerry R.</given-names></name><xref rid="A2" ref-type="aff">&#x02021;</xref></contrib><contrib contrib-type="author"><name><surname>Snyder</surname><given-names>Jay L.</given-names></name><xref rid="FN1" ref-type="author-notes">#</xref></contrib><contrib contrib-type="author"><name><surname>Reeder</surname><given-names>Aaron</given-names></name><xref rid="A3" ref-type="aff">&#x02225;</xref></contrib><contrib contrib-type="author"><name><surname>Bell</surname><given-names>Suzanne</given-names></name><xref rid="A4" ref-type="aff">&#x022a5;</xref></contrib></contrib-group><aff id="A1"><label>&#x02020;</label>National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Evaluation and Testing Branch (CDC/NIOSH/NPPTL/ETB), Centers for Disease Control and Prevention, 1095 Willowdale Road, Morgantown, West Virginia 26505, United States</aff><aff id="A2"><label>&#x02021;</label>Department of Medicine, University of California, San Diego, 9500 Gilman Drive, La Jolla, California 92093, United States</aff><aff id="A3"><label>&#x02225;</label>National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory, Evaluation and Testing Branch (CDC/NIOSH/NPPTL/ETB), Centers for Disease Control and Prevention, 626 Cochrans Mill Road, Pittsburgh, Pennsylvania 15236, United States</aff><aff id="A4"><label>&#x022a5;</label>C. Eugene Bennett Department of Chemistry, West Virginia University, 217 Clark Hall, Morgantown, West Virginia 26506, United States</aff><author-notes><fn fn-type="present-address" id="FN1"><label>#</label><p id="P1">Present Address: 113 Snee Drive, Jefferson Hills, PA, 15025, United States</p></fn><fn fn-type="con" id="FN2"><p id="P2">Author Contributions</p><p id="P3">The manuscript was written through contributions of all authors. All authors have given approval to the final version of the manuscript. These authors contributed equally.</p></fn><corresp id="CR1"><label>*</label><bold>Corresponding Author</bold>: <email>lgreenawald@cdc.gov</email>. Phone: 304-285-5932.</corresp></author-notes><pub-date pub-type="nihms-submitted"><day>28</day><month>3</month><year>2023</year></pub-date><pub-date pub-type="ppub"><day>27</day><month>10</month><year>2017</year></pub-date><pub-date pub-type="epub"><day>12</day><month>10</month><year>2017</year></pub-date><pub-date pub-type="pmc-release"><day>10</day><month>4</month><year>2023</year></pub-date><volume>2</volume><issue>10</issue><fpage>1458</fpage><lpage>1466</lpage><abstract id="ABS1"><p id="P4">An inexpensive red, green, blue (RGB) color sensor was developed for detecting low ppm concentrations of hydrogen cyanide gas. A piece of glass fiber filter paper containing monocyanocobinamide [CN(H<sub>2</sub>O)Cbi] was placed directly above the RGB color sensor and an on chip LED. Light reflected from the paper was monitored for RGB color change upon exposure to hydrogen cyanide at concentrations of 1.0&#x02013;10.0 ppm as a function of 25%, 50%, and 85% relative humidity. A rapid color change occurred within 10 s of exposure to 5.0 ppm hydrogen cyanide gas (near the NIOSH recommended exposure limit). A more rapid color change occurred at higher humidity, suggesting a more effective reaction between hydrogen cyanide and CN(H<sub>2</sub>O)Cbi. The sensor could provide the first real time respirator end-of-service-life alert for hydrogen cyanide gas.</p></abstract><abstract id="ABS2" abstract-type="graphical"><title>Graphical Abstract</title><p id="P5">
<graphic xlink:href="nihms-1880413-f0001.jpg" position="anchor"/>
</p></abstract><kwd-group><kwd>cobinamide</kwd><kwd>hydrogen cyanide</kwd><kwd>paper-based sensor</kwd><kwd>respirator</kwd><kwd>end-of-service-life indicator</kwd></kwd-group></article-meta></front><body><p id="P6">Air-purifying respirators are worn in occupational settings to protect the worker when the air is contaminated with harmful gases, aerosols, or vapors. Unfortunately, the user generally does not know when to change a canister/cartridge before breakthrough occurs&#x02014;i.e., when the activated carbon is sufficiently saturated such that a harmful amount of the contaminant may penetrate the canister/cartridge.<sup><xref rid="R1" ref-type="bibr">1</xref></sup> Software models generated by respirator manufacturers are used to help estimate when breakthrough will occur, but the user may not be aware of unpredictable input data such as types and concentrations of toxic chemicals, relative humidity, and breathing rate. Additionally, most software models were developed for organic vapors.</p><p id="P7">In 1984, the National Institute for Occupational Safety and Health (NIOSH) published standards for certifying active end-of-service-life indicators (AESLI) to encourage development of sensors that can indicate imminent breakthrough.<sup><xref rid="R2" ref-type="bibr">2</xref></sup> The standards require that the sensors be embedded in a respirator carbon bed and provide a real-time alert (e.g., flashing light emitting diode (LED)) when the cartridge is near sufficient saturation to cause imminent vapor breakthrough. Current challenges in developing respirator cartridge sensors are the effects of humidity, selectivity, size, weight, and power restrictions. Additionally, manufacturers prefer to limit sensor costs to about $1 per cartridge, and $20&#x02013;$50 for sensor-related fixtures and electronics.<sup><xref rid="R2" ref-type="bibr">2</xref></sup> Only a limited number of colorimetric and qualitative end-of-service-life indicators (ESLI) are commercially available, e.g., for organic vapor; these rely on subjective visual identification of a color change.<sup><xref rid="R3" ref-type="bibr">3</xref></sup> For passive ESLIs, the user must routinely monitor the sensor for color change. This is inappropriate in poorly lit environments, in full facepiece respirators that may become fogged, or for color-blind persons. Currently, no NIOSH-approved AESLIs exist.</p><p id="P8">We have previously shown that diffuse reflectance of cobinamide&#x02014;a vitamin B<sub>12</sub> derivative&#x02014;immobilized on cellulose and glass fiber filter paper is an effective and inexpensive AESLI prototype for detecting hydrogen cyanide (HCN) and hydrogen sulfide (H<sub>2</sub>S) gas.<sup><xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R5" ref-type="bibr">5</xref></sup> However, miniaturization and fabrication of spectrometers may be difficult and expensive. Color sensors are an economical and easily miniaturized alternative, where light is separated into a set of colors, primarily red (R), green (G), and blue (B).<sup><xref rid="R6" ref-type="bibr">6</xref></sup> Modern color sensors are used to assess pH, and to quantify color in the food, beverage, cosmetic, printing, and textile industries.<sup><xref rid="R6" ref-type="bibr">6</xref>,<xref rid="R7" ref-type="bibr">7</xref></sup> Many color sensors do not function in real-time&#x02014;i.e., the sensor is exposed to the analyte and scanned (via flatbed scanner) into a computer, which is not realistic for a respirator ESLI application. The color analysis is performed by software (e.g., Adobe Photoshop) or on a smartphone application in terms of RGB values of 8-bit resolution (256-bit color scale with 255, 255, 255 corresponding to white, and 0, 0, 0 corresponding to black).<sup><xref rid="R8" ref-type="bibr">8</xref>,<xref rid="R9" ref-type="bibr">9</xref></sup> Data are frequently presented in terms of total color differences (&#x00394;<italic toggle="yes">C</italic>) using the Euclidean distance equation:<sup><xref rid="R9" ref-type="bibr">9</xref>,<xref rid="R10" ref-type="bibr">10</xref></sup>
<disp-formula id="FD1">
<label>(1)</label>
<mml:math id="M1" display="block"><mml:mrow><mml:mi mathvariant="normal">&#x00394;</mml:mi><mml:mi>C</mml:mi><mml:mo>=</mml:mo><mml:msqrt><mml:mrow><mml:msup><mml:mrow><mml:mfenced><mml:mrow><mml:mi mathvariant="normal">&#x00394;</mml:mi><mml:mi>R</mml:mi></mml:mrow></mml:mfenced></mml:mrow><mml:mn>2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mrow><mml:mfenced><mml:mrow><mml:mi mathvariant="normal">&#x00394;</mml:mi><mml:mi>G</mml:mi></mml:mrow></mml:mfenced></mml:mrow><mml:mn>2</mml:mn></mml:msup><mml:mo>+</mml:mo><mml:msup><mml:mrow><mml:mfenced><mml:mrow><mml:mi mathvariant="normal">&#x00394;</mml:mi><mml:mi>B</mml:mi></mml:mrow></mml:mfenced></mml:mrow><mml:mn>2</mml:mn></mml:msup></mml:mrow></mml:msqrt></mml:mrow></mml:math>
</disp-formula>
where &#x00394;<italic toggle="yes">R</italic>, &#x00394;<italic toggle="yes">G</italic>, and &#x00394;<italic toggle="yes">B</italic> are the change in R, G, and B colors from reference values, respectively.</p><p id="P9">We chose HCN gas to assess proof-of-concept of an RGB color sensor and compare it to a previously reported diffuse reflectance configuration which comprised a tungsten halogen light source, miniature spectrometer, and bifurcated optical fiber (herein referred to as the &#x0201c;diffuse reflectance configuration&#x0201d;).<sup><xref rid="R4" ref-type="bibr">4</xref></sup> Hydrogen cyanide has a NIOSH short-term recommended exposure limit (REL) of 4.7 parts-per-million (ppm) HCN; this means a worker should not inhale HCN concentrations above 4.7 ppm during a 15 min time-weighted average exposure at any time during a 10 h work day. A HCN ESLI located in the back end of a respirator canister must be able to rapidly detect a minimum 4.7 ppm of HCN. Paper is a unique substrate for real-time, low cost sensors because paper offers a bright, high-contrast backing and is highly porous, an advantage for rapid adsorption of gas phase analytes. We chose cobinamide (Cbi) as the indicating compound to detect HCN; it can bind up to two cyanide (CN<sup>&#x02212;</sup>) ions with an overall affinity of <italic toggle="yes">K</italic><sub>a</sub> = 10<sup>22</sup> M<sup>&#x02212;2</sup>.<sup><xref rid="R11" ref-type="bibr">11</xref></sup> The Cbi structure is shown in <xref rid="SD1" ref-type="supplementary-material">Figure S1</xref> (<xref rid="SD1" ref-type="supplementary-material">Supporting Information</xref>), where the X and Y ligands can be OH<sup>&#x02212;</sup>, H<sub>2</sub>O, HS<sup>&#x02212;</sup>, or CN<sup>&#x02212;</sup>, among others. At neutral pH in water, Cbi exists as the mixed aquo-hydroxo complex OH(H<sub>2</sub>O)Cbi, termed aquohydroxocobinamide (with Co in 3+ oxidation state).<sup><xref rid="R12" ref-type="bibr">12</xref></sup> Adding a 1:1 mol equiv of CN<sup>&#x02212;</sup> to OH(H<sub>2</sub>O)Cbi produces CN(H<sub>2</sub>O)Cbi (monocyanocobinamide), which on binding a second cyanide ion provides fast and sensitive detection of cyanide forming CN<sub>2</sub>Cbi (dicyanocobinamide), with resulting characteristic spectral shifts and a visible color change.<sup><xref rid="R12" ref-type="bibr">12</xref>,<xref rid="R13" ref-type="bibr">13</xref></sup></p><p id="P10">The RGB sensor developed is enclosed in a light-tight holder, allowing a CN(H<sub>2</sub>O)Cbi-immobilized paper circle to be exposed to HCN gas. The sensor is regulated by a microcontroller, which converts data to real time RGB readouts and allows for rapid color change analysis. Color change was monitored as a function of HCN concentration, time, and percent relative humidity (%RH). We compared the RGB color sensor, a diffuse reflectance configuration, and a commercially available electrochemical detector to monitor HCN breakthrough of respirator canisters.<sup><xref rid="R4" ref-type="bibr">4</xref></sup></p><sec id="S1"><title>MATERIALS AND METHODS</title><sec id="S2"><title>Chemicals and Materials.</title><p id="P11">Aquohydroxocobinamide [OH(H<sub>2</sub>O)-Cbi], Co(III) was synthesized from hydroxocobalamin as described previously.<sup><xref rid="R14" ref-type="bibr">14</xref></sup> A benchtop UV&#x02013;vis spectrometer (Thermo Scientific Evolution 300) was used to verify the CN(H<sub>2</sub>O)Cbi solution concentration under the following conditions: pH = 7.0 in deionized H<sub>2</sub>O; 1.0 cm path length; molar extinction coefficient of 10,450 M<sup>&#x02212;1</sup> cm<sup>&#x02212;1</sup> at 583 nm.<sup><xref rid="R15" ref-type="bibr">15</xref></sup> Potassium cyanide (KCN) was purchased from Fisher Scientific (granular; certified ACS) and dissolved in 1 M sodium hydroxide (NaOH; (Fisher Scientific, certified). Stock HCN gas was purchased from Butler Gas at a concentration of 495.0 (&#x000b1;2%) ppm. Gelman Sciences A/E Borosilicate glass fiber filter paper (without binder, 330 <italic toggle="yes">&#x003bc;</italic>m thick, 1 <italic toggle="yes">&#x003bc;</italic>m pore size) was used as the support media. Deionized water was from an 18 M&#x003a9;-cm deionized in-line water system (Thermo Scientific Micropure).</p></sec><sec id="S3"><title>Preparation of Paper Substrates.</title><p id="P12">Glass fiber filter paper was cut into uniform 6.0 &#x000b1; 0.5 mm diameter circles. CN(H<sub>2</sub>O)Cbi was pipetted onto the paper circles and allowed to dry fully (&#x0223c;1 h). The CN(H<sub>2</sub>O)Cbi concentration was optimized by comparing color change after pipetting 15.0 <italic toggle="yes">&#x003bc;</italic>L of 50.0, 100.0, 200.0, and 300.0 <italic toggle="yes">&#x003bc;</italic>M CN(H<sub>2</sub>O)Cbi before and after exposure to 5.0 ppm of HCN. The selected CN(H<sub>2</sub>O)Cbi concentration was compared across 30 samples using the RGB sensor, along with RGB values for 12 blank samples. Data were analyzed by the average of each R, G, and B value using standard deviation (SD), relative standard deviation (%RSD), and 95% confidence interval (CI).</p></sec><sec id="S4"><title>RGB Color Sensor and Test Holder.</title><p id="P13">An RGB color sensor chip (TCS34725, ams) was purchased from Adafruit (<ext-link xlink:href="https://www.adafruit.com" ext-link-type="uri">adafruit.com</ext-link>).<sup><xref rid="R16" ref-type="bibr">16</xref></sup> The chip incorporates the sensor along with a neutral white, 4150 K LED to illuminate the material of interest (<xref rid="F1" ref-type="fig">Figure 1</xref>).<sup><xref rid="R16" ref-type="bibr">16</xref></sup></p><p id="P14">The photodiode color array comprises a 4 &#x000d7; 3 array of red, green, and blue-filtered photodiodes, as well as three clear (unfiltered) photodiodes. Four integrated analog-to-digital (ADC) converters simultaneously convert the amplified photodiode currents to a 10-bit digital value.<sup><xref rid="R16" ref-type="bibr">16</xref></sup> The results are then transferred to data registers and communicated to a microcontroller through a 400 kHz, Inter-Integrated Circuit (I<sup>2</sup>C) serial bus.<sup><xref rid="R16" ref-type="bibr">16</xref></sup> The LED is indium gallium nitride (InGaN) based, and has a viewing angle of 120&#x000b0;, with maximum illumination in the desired spectrum ranges (400&#x02013;700 nm).<sup><xref rid="R16" ref-type="bibr">16</xref></sup> An infrared (IR) blocking filter is integrated on the chip and located near the color sensing photodiodes. The manufacturer reports that this minimizes the IR spectral component and allows more accurate color measurements.<sup><xref rid="R16" ref-type="bibr">16</xref></sup></p><p id="P15">Header pins were soldered directly onto the backside of the chip to ensure efficient electrical contact when connecting to a ribbon cable (<xref rid="SD1" ref-type="supplementary-material">Figure S2A</xref>). A ribbon cable was soldered to the sensor pins and used to connect the RGB sensor to appropriate ports on the Arduino microcontroller (<xref rid="SD1" ref-type="supplementary-material">Figure S2B</xref> and <xref rid="SD1" ref-type="supplementary-material">C</xref>). The microcontroller was connected to a laptop via universal serial bus (USB) cable and controlled with software using I<sup>2</sup>C communication. Color View software sketch was used to control the color sensor and provide output data in separate R, G, B, and clear light elements. Sensor output values, separated by RGB values, are in terms of counts or digital values (D.V.; particularly counts/<italic toggle="yes">&#x003bc;</italic>W/cm<sup>2</sup>). The sketch was modified to output RGB values at 6 s intervals, and calculate the total change in color (&#x00394;<italic toggle="yes">C</italic>) at each measurement using <xref rid="FD1" ref-type="disp-formula">eq 1</xref>. The sensor can be modified to indicate when a minimum &#x00394;<italic toggle="yes">C</italic> is reached by flashing the LED (to simulate reaching end-of-service-life; <xref rid="SD1" ref-type="supplementary-material">Figure S2D</xref>).</p><p id="P16">A test holder housed the RGB sensor (<xref rid="SD1" ref-type="supplementary-material">Figure S2D</xref>). The holder incorporates a glass window separating HCN from the sensor electronics, while allowing HCN to flow over the Cbi-immobilized glass fiber paper. A complete assembly can be seen in <xref rid="SD1" ref-type="supplementary-material">Figure S2E</xref>. Light is reflected from the paper circle and detected by the color sensor photodiodes. &#x00394;<italic toggle="yes">C</italic> is computed by the microcontroller program using <xref rid="FD1" ref-type="disp-formula">eq 1</xref>.</p></sec><sec id="S5"><title>System Optimization.</title><p id="P17">When light is detected by the photodiodes, current is generated that is converted to voltage and separated into respective R, G, and B output values in the form of digital values (D.V.). A sensor clock runs at 425 Hz, or 2.4 ms, the lowest possible single integration time for this configuration. The chip uses a 10-bit ADC, and the sensor has a 3,800,000:1 dynamic range, with adjustable integration time (2.4&#x02013;700 ms) and gain for increased sensitivity.<sup><xref rid="R16" ref-type="bibr">16</xref></sup> An integration time of 700 ms yields 256 cycles, or 65,535 maximal counts (i.e., 16-bit resolution). &#x00394;<italic toggle="yes">C</italic> values were computed every 6 s based on initial RGB values for CN(H<sub>2</sub>O)Cbi calculated by <xref rid="FD1" ref-type="disp-formula">eq 1</xref>.</p></sec><sec id="S6"><title>Chip-LED and Color Sensor Responsivity.</title><p id="P18">A previously described diffuse reflectance configuration comprising a bifurcated optical fiber, Ocean Optics miniature spectrometer, and tungsten halogen light source was used here to determine the normalized intensity of the chip-LED.<sup><xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R5" ref-type="bibr">5</xref></sup> The common end of the bifurcated fiber optic was held close to the LED at different angles, to capture the average LED spectrum (<italic toggle="yes">n</italic> = 3) by the spectrometer. Spectral responsivity of the on-chip LED was determined by holding a mirror directly above both the chip-LED and photodiodes and recording the RGB values.</p><p id="P19">Experiments were performed to ensure the chip-LED did not degrade or alter the Cbi spectrum when the paper is placed in the holder and exposed to the LED. Using the diffuse reflectance configuration, an initial Kubelka&#x02013;Munk reflectance (in terms of the remission function, F(R)) spectrum was taken and the paper circle was inserted into the RGB color sensor holder for 60 min (<italic toggle="yes">n</italic> = 3; LED on). Final F(R) spectra were taken immediately after using the same diffuse reflectance configuration. Total &#x00394;<italic toggle="yes">C</italic> after 60 min was calculated (<italic toggle="yes">n</italic> = 6).</p><p id="P20">To determine &#x00394;<italic toggle="yes">C</italic> drift in the absence of HCN, samples were placed in the sensor holder for 30 min with the desired %RH (25%, 50%, or 85%). Reference R (i.e., R<sub>1</sub>), G (i.e., G<sub>1</sub>), and B (i.e., B<sub>1</sub>) values were recorded at <italic toggle="yes">t</italic> = 0. &#x00394;<italic toggle="yes">C</italic> values were obtained every 6 s. Average &#x00394;<italic toggle="yes">C</italic> values (in triplicate) were evaluated for each %RH.</p></sec><sec id="S7"><title>HCN Flow Experimental Setup: NIOSH REL.</title><p id="P21">A low HCN concentration gas-flow experimental setup is shown in <xref rid="SD1" ref-type="supplementary-material">Figure S3</xref> and was described previously.<sup><xref rid="R4" ref-type="bibr">4</xref></sup> Three mass flow controllers (MFCs; Alicat Scientific) regulate air flow, HCN concentration, and the percent relative humidity (%RH) based on air passing through a water bubbler. The HCN was diluted with oil-free compressed air and the concentration was confirmed using an HCN-specific electrochemical detector (Interscan RM, 0&#x02013;50.0 &#x000b1; 0.1 ppm). The lowest HCN concentration that could be measured accurately was 1.0 ppm of HCN. All tubing was made of Teflon (PFTE) material. Experiments were performed at a carrier gas flow rate of 0.75 L per minute (LPM) at 25%, 50%, and 85% RH at room temperature. This flow rate prevents back pressure in the sensor holder, and although it does not correlate with air flow through a respirator canister/cartridge, it was chosen to focus on studying the &#x00394;<italic toggle="yes">C</italic> for the reaction between HCN and CN(H<sub>2</sub>O)Cbi. The small size of the sensor holder combined with the 0.75 LPM flow rate yields a several second time constant for a step change in HCN concentration.</p><p id="P22">The system was flushed with air at the desired %RH (no HCN) for 1&#x02013;2 h. A piece of CN(H<sub>2</sub>O)Cbi-immobilized paper was then placed in the test holder and the initial RGB values (pre-HCN exposure) were recorded. The paper circles were allowed to equilibrate with the desired %RH for 15 min, and once the desired HCN concentration was detected by the electrochemical detector, a three-way valve was switched to direct air through the test holder, above the CN(H<sub>2</sub>O)-Cbi-immobilized paper circle. The valve switching time was designated as the start of the experiment (i.e., <italic toggle="yes">t</italic> = 0). The CN(H<sub>2</sub>O)Cbi paper was then exposed to HCN concentrations of 1.0, 3.0, 5.0, and 10.0 ppm, where &#x00394;<italic toggle="yes">C</italic> was calculated using RGB values recorded at <italic toggle="yes">t</italic> = 0, 1, 5, 10, and 15 min after HCN exposure (<italic toggle="yes">n</italic> = 3 for each concentration). The R, G, B values at <italic toggle="yes">t</italic> = 0 are the reference values (i.e., R<sub>1</sub>, G<sub>1</sub>, B<sub>1</sub>) after equilibration.</p></sec><sec id="S8"><title>HCN Flow Experimental Setup: HCN Breakthrough of Respirator Canisters.</title><p id="P23">HCN breakthrough experiments were performed at the NIOSH, National Personal Protective Technology Laboratory (NPPTL) facility in Pittsburgh, PA. The standard test procedure (STP) with associated experimental equipment and setup titled &#x0201c;Determination of CBRN Acid Gases (Hydrogen Cyanide) Service-Life Test, Air-Purifying Standard Test Procedure (STP-CET-APRS-STP-CBRN-0303)&#x0201d; can be found online.<sup><xref rid="R17" ref-type="bibr">17</xref></sup> In short, an Interscan electrochemical HCN detector was placed downstream of the respirator canister to sample effluent flow and monitor HCN breakthrough from NIOSH-approved Chemical, Biological, Radiological, and Nuclear (CBRN) canisters used to provide protection against HCN. This downstream electrochemical detector was calibrated with certified 10.1 ppm of HCN (&#x000b1;5%). To verify the challenge gas concentration, a Photoacoustic Multi-Gas Monitor 1314A (California Analytical Instruments Model UA989) with an optical filter for HCN was used. This instrument samples gas at 30 mL/min (&#x000b1;1% of measured value); range for HCN is (0.8&#x02013;8000) &#x000b1; 0.08 ppm. This instrument was calibrated with certified 1001 &#x000b1; 2% ppm of HCN calibration gas. All valves were controlled by a custom LabVIEW based software. Average %RH, temperature, challenge HCN concentration (photoacoustic gas monitor), breakthrough concentration (electrochemical detector), and test time were monitored and stored by the software in real time. The high concentration gas-flow experimental setup can be seen in <xref rid="SD1" ref-type="supplementary-material">Figure S4</xref>. The canisters were mounted on a fixture within the airtight testing chamber. One opening located on the side of the test chamber was used for entry of the challenge gas, where exit gas is forced through the canister and through an outlet in the back of the test chamber, where the effluent gas is sampled by the downstream detector.<sup><xref rid="R17" ref-type="bibr">17</xref></sup></p><p id="P24">The system was initially flushed with clean, oil-free air at 64 LPM at the desired %RH (no HCN) for 30 min, and then evaluated by the electrochemical detector to ensure a reading of 0.0 ppm of HCN. Air was pulled through the test holder in the diffuse reflectance configuration at 1.0 LPM (&#x000b1;5%) and through the RGB color sensor holder at 0.75 LPM (&#x000b1;5%) by a Gilian Air Sampling Pump (GilAir-3, <xref rid="SD1" ref-type="supplementary-material">Figure S6</xref>). The tubing from the test chamber to each sensor holder was 1.2 m long, permitting a time delay of 2.3 s. A piece of CN(H<sub>2</sub>O)Cbi-impregnated paper was then placed in each holder; the initial reflectance spectrum was recorded, along with the initial RGB values. The diffuse reflectance spectrum of CN(H<sub>2</sub>O)Cbi-immobilized paper was designated as the &#x0201c;blank&#x0201d; to monitor changes in the CN(H<sub>2</sub>O)Cbi spectrum. Diffuse reflectance spectra and RGB values were recorded at various time intervals throughout each experiment and at HCN breakthrough.</p><p id="P25">To determine if distinguishable Cbi spectral shifts were a result of a cyanogen byproduct due to reaction of HCN with the activated carbon chemical impregnants, a Kin-TEK Trace Source cyanogen permeation tube was used to expose 5.0 &#x000b1; 2% (CN)<sub>2</sub> over the Cbi paper sensor at 0.49 &#x000b1; 0.01 LPM at 30.00 &#x000b1; 0.01 &#x000b0;C by using the following permeation tube calculator:
<disp-formula id="FD2">
<label>(2)</label>
<mml:math id="M2" display="block"><mml:mrow><mml:msub><mml:mi>C</mml:mi><mml:mrow><mml:mtext>ppmv</mml:mtext></mml:mrow></mml:msub><mml:mo>=</mml:mo><mml:mfrac><mml:mrow><mml:msub><mml:mi>E</mml:mi><mml:mrow><mml:mrow><mml:mrow><mml:mtext>ng/min</mml:mtext></mml:mrow></mml:mrow></mml:mrow></mml:msub><mml:mo>&#x000d7;</mml:mo><mml:mn>22.41</mml:mn></mml:mrow><mml:mrow><mml:mtext>MW</mml:mtext><mml:mo>&#x000d7;</mml:mo><mml:msub><mml:mi>F</mml:mi><mml:mrow><mml:mtext>pd</mml:mtext></mml:mrow></mml:msub></mml:mrow></mml:mfrac></mml:mrow></mml:math>
</disp-formula>
where <italic toggle="yes">C</italic><sub>ppmv</sub> is the generated concentration (ppm by volume), <italic toggle="yes">E</italic><sub>ng/min</sub> is the emission rate of component from the permeation tube, MW is the molecular weight of the component (g/mol), 22.41 is the volume (L) of 1 mol of gas at standard temperature and pressure, and <italic toggle="yes">F</italic><sub>pd</sub> is the primary dilution flow rate (standard cubic centimeters, sccm). The cyanogen permeation tube was stored within a heated Kin-Tek Flexstream Gas Standards Generator. The flow rate was set to generate 5.0 &#x000b1; 0.1 ppm cyanogen at an emission rate of 5837 ng/min at 30 &#x000b0;C.</p></sec></sec><sec id="S9"><title>RESULTS AND DISCUSSION</title><sec id="S10"><title>Volume and Concentration of Cobinamide.</title><p id="P26">In previous studies, glass fiber filter paper demonstrated larger reflectance signals than cellulose filter paper, presumably because the glass fiber paper is thicker and allows more light to reach the detector in a reflectance configuration.<sup><xref rid="R4" ref-type="bibr">4</xref>,<xref rid="R5" ref-type="bibr">5</xref></sup> Additionally, glass fiber paper is less affected by water vapor. The optimal concentration and volume of CN(H<sub>2</sub>O)Cbi placed on the paper was found to be 15.00 &#x000b1; 0.02 <italic toggle="yes">&#x003bc;</italic>L of 200.0 &#x000b1; 0.2 <italic toggle="yes">&#x003bc;</italic>M. This volume and concentration of CN(H<sub>2</sub>O)Cbi was pipetted onto the center of each piece of paper leading to &#x0223c;3.6 <italic toggle="yes">&#x003bc;</italic>g CN(H<sub>2</sub>O)Cbi per paper circle. The CN(H<sub>2</sub>O)Cbi solution diffused uniformly across the paper circle, and the wetted paper was allowed to dry fully for 1 h at room temperature (&#x0223c;21 &#x000b0;C). These optimized conditions yielded a reflectance spectrum with subjectively acceptable signal-to-noise ratio without being too concentrated, which would result in lower sensitivity in determining small color changes. The spotted papers were stored at 4 &#x000b0;C. The average RGB values of blank (<italic toggle="yes">n</italic> = 12) and 200 <italic toggle="yes">&#x003bc;</italic>M Cbi-immobilized paper (<italic toggle="yes">n</italic> = 30) are shown in <xref rid="SD1" ref-type="supplementary-material">Table S1</xref>.</p></sec><sec id="S11"><title>UV&#x02013;vis Spectra of Cobinamide.</title><p id="P27">The absorbance spectra of 20 <italic toggle="yes">&#x003bc;</italic>M OH(H<sub>2</sub>O)Cbi, CN(H<sub>2</sub>O)Cbi, and (CN)<sub>2</sub>Cbi in aqueous solution are shown in <xref rid="F2" ref-type="fig">Figure 2A</xref>. When a second cyanide ion binds to CN(H<sub>2</sub>O)Cbi, a peak appears at 583 nm, absorption at 450&#x02013;500 nm decreases, an isosbestic point occurs at 531 nm, and a visible violet color develops. The absorption spectrum of a 50 <italic toggle="yes">&#x003bc;</italic>M CN(H<sub>2</sub>O)Cbi solution is similar to the optical fiber diffuse reflectance spectra of CN(H<sub>2</sub>O)Cbi on glass fiber paper before and after excess CN<sup>&#x02212;</sup> (<xref rid="F2" ref-type="fig">Figure 2B</xref>), indicating the binding of gas-phase CN<sup>&#x02212;</sup> is successful.</p></sec><sec id="S12"><title>Effect of LED and Drift on Cbi Spectra.</title><p id="P28">The average (<italic toggle="yes">n</italic> = 3) normalized intensity spectrum of the chip-LED is shown in <xref rid="SD1" ref-type="supplementary-material">Figure S5</xref>. The warm neutral white LED emits a similar spectra shown in the manufacturer datasheet with a distinctive InGaN LED peak observable at &#x0223c;450 nm.<sup><xref rid="R16" ref-type="bibr">16</xref></sup> When a mirror is placed directly above the chip-LED and photodiodes, the RGB values are recorded and normalized to the highest R (615 nm), G (525 nm), or B (465 nm) value. The spectral response using a mirror, blank glass fiber paper, and CN(H<sub>2</sub>O)Cbi-immobilized glass fiber paper were similar at 465, 525, and 615 nm. A similar normalization approach was performed for blank glass fiber response (<italic toggle="yes">n</italic> = 12) and 200 <italic toggle="yes">&#x003bc;</italic>M CN(H<sub>2</sub>O)Cbi on glass fiber paper (<italic toggle="yes">n</italic> = 30) with the data shown in <xref rid="SD1" ref-type="supplementary-material">Table S2</xref>. The normalized data suggest an appropriate spectral response of the photodiodes for the blank glass fiber paper and immobilized CN(H<sub>2</sub>O)Cbi within the wavelengths of interest.</p><p id="P29">The chip-LED did not alter the Cbi spectrum when the paper sensor was placed in the sensor holder for 1 h. Using the optical fiber diffuse reflectance setup, an initial F(R) spectrum for 200 <italic toggle="yes">&#x003bc;</italic>M CN(H<sub>2</sub>O)Cbi-fixed paper was recorded, after which the paper circle was inserted into the RGB color sensor holder. The overall spectrum of CN(H<sub>2</sub>O)Cbi remained the same. The total average &#x00394;<italic toggle="yes">C</italic> after 60 min of LED exposure was 195.6 &#x000b1; 24.8 (uncertainty in 95% CI; <italic toggle="yes">n</italic> = 6) with data shown in <xref rid="SD1" ref-type="supplementary-material">Table S3</xref>.</p></sec><sec id="S13"><title>Cobinamide Detection of HCN at the NIOSH REL Using the RGB Color Sensor.</title><p id="P30">A paper circle impregnated with CN(H<sub>2</sub>O)Cbi was secured in the sensor holder and exposed to HCN gas. The average R, G, and B values after exposure to 5.0 ppm of HCN (close to the NIOSH HCN REL) at 25%RH are shown in <xref rid="F3" ref-type="fig">Figure 3</xref>. The R (dotted line) and G (dashed line) values decreased, while the B values (solid line) increased as a function of time. The increase and decrease in readings correlate well with (CN)<sub>2</sub>Cbi absorbance intensities&#x02014;i.e., upon formation of (CN)<sub>2</sub>Cbi, an absorbance increase occurs from 531 to 600 nm, while a decrease occurs from &#x0223c;420 to 531 nm (<xref rid="F2" ref-type="fig">Figure 2B</xref>). A decrease in absorbance in the blue region of (CN)<sub>2</sub>Cbi absorption increases the reflectance/signal detected by the RGB color sensor, and thus an increase in the blue-filtered photodiode signal is observed. It would be possible to monitor just the &#x00394;<italic toggle="yes">B</italic>, but the addition of &#x00394;<italic toggle="yes">R</italic> and &#x00394;<italic toggle="yes">G</italic> help compensate for drift and potential interfering gases&#x02014;this will be further explored. &#x00394;<italic toggle="yes">C</italic> was calculated using <xref rid="FD1" ref-type="disp-formula">eq 1</xref>; the red photodiode displayed the largest response, followed by the G and B photodiodes with &#x00394;<italic toggle="yes">C</italic> corresponding to 1910 &#x000b1; 130, 880 &#x000b1; 110, and 420 &#x000b1; 30, respectively (uncertainty expressed by S.D.).</p></sec><sec id="S14"><title>Detection at non-NIOSH REL HCN Concentrations.</title><p id="P31">Exposing the paper to 1.0, 3.0, and 10.0 ppm of HCN at 25% RH increased the &#x00394;<italic toggle="yes">C</italic> as a function of HCN concentration, where exposure to 3.0 and 10.0 ppm cause the response to plateau after &#x0223c;15 min (<xref rid="F4" ref-type="fig">Figure 4A</xref>, <italic toggle="yes">n</italic> = 3). All concentrations at 25%RH had similar response curves, but yielded different final &#x00394;<italic toggle="yes">C</italic> values and slopes; average initial &#x00394;<italic toggle="yes">C</italic> values (<italic toggle="yes">n</italic> = 3) are in <xref rid="F4" ref-type="fig">Figure 4B</xref>. The 25%RH blank is the average drift response of a CN(H<sub>2</sub>O)Cbi paper exposed to 0.0 ppm of HCN air at 25%RH after 15 min of equilibration (final &#x00394;<italic toggle="yes">C</italic>= 117.3 &#x000b1; 66.6, <italic toggle="yes">n</italic> = 3). As reported earlier, the average &#x00394;<italic toggle="yes">C</italic> drift after 60 min of 0.0 ppm of HCN at 25%RH was 195.6 &#x000b1; 24.8; thus, the &#x00394;<italic toggle="yes">C</italic> of the RGB color sensor exposed to 1.0 ppm of HCN after 15 min is 10&#x000d7; this drift. Data for each concentration at 25%RH are shown in <xref rid="SD1" ref-type="supplementary-material">Table S4</xref>.</p></sec><sec id="S15"><title>Effect of Percent Relative Humidity (%RH) on HCN Detection.</title><p id="P32">Increasing the %RH to 50% increased the &#x00394;<italic toggle="yes">C</italic> at all HCN concentrations compared to exposure to 25%RH. Total &#x00394;<italic toggle="yes">C</italic> after 15 min for the R, G, and B photodiodes were 3100 &#x000b1; 500, 1700 &#x000b1; 500, and 790 &#x000b1; 70, respectively. Average R, G, and B values for 5.0 ppm of HCN at 85%RH are shown in <xref rid="F5" ref-type="fig">Figure 5A</xref>. Each color-filtered photodiode responds rapidly, with the signal reaching steady state within 2 min of HCN exposure. The plateau for the remainder of the experiment is stable. The total &#x00394;<italic toggle="yes">C</italic> after 15 min for the R, G, and B photodiodes at 85% RH are 3600 &#x000b1; 300, 1500 &#x000b1; 100, and 900 &#x000b1; 90, respectively (<italic toggle="yes">n</italic> = 3). The average computed total &#x00394;<italic toggle="yes">C</italic> for each HCN concentration at 85%RH is shown in <xref rid="F5" ref-type="fig">Figure 5B</xref> (<italic toggle="yes">n</italic> = 3), with data in <xref rid="SD1" ref-type="supplementary-material">Table S4</xref>. The increased &#x00394;<italic toggle="yes">C</italic> may be attributed to water vapor adsorption by the paper, creating a more solution-like medium for CN<sup>&#x02212;</sup> binding to CN(H<sub>2</sub>O)Cbi and thus allowing a more rapid reaction.</p><p id="P33">To assess reversibility, HCN was added to the gas stream at 0 and 30 min removed at <italic toggle="yes">t</italic> = 15 and 45 min (<xref rid="F6" ref-type="fig">Figure 6</xref>). At each relative humidity, a small decrease in &#x00394;<italic toggle="yes">C</italic> was observed when HCN was removed, which can be attributed to a slow, reversible removal of CN<sup>&#x02212;</sup> from the (CN)<sub>2</sub>Cbi compound and a resultant color closer to that of the reference (i.e., CN(H<sub>2</sub>O)Cbi on paper). This demonstrated that the reaction is partially reversible in the gas-phase when CN<sup>&#x02212;</sup> is removed. For an ESLI, reversibility is not relevant as long as the user is alerted upon initial breakthrough and detection of the gas. In summary, high &#x00394;<italic toggle="yes">C</italic> values are obtained by the RGB sensor as a function of increasing both the HCN concentration and/or % RH (<xref rid="SD1" ref-type="supplementary-material">Table S4</xref>). Steady-state conditions are reached rapidly at higher %RH, and thus the difference in &#x00394;<italic toggle="yes">C</italic> values between 1 and 15 min exposure times at higher HCN concentrations is reduced.</p></sec><sec id="S16"><title>HCN Canister Breakthrough Experiments: Diffuse Reflectance Configuration vs Electrochemical Detector.</title><p id="P34">A CBRN respirator canister was placed in the test fixture and exposed to a challenge concentration of 1000 &#x000b1; 2% ppm of HCN until breakthrough was observed. A comparison of breakthrough curves for the Cbi paper using the diffuse reflectance configuration (primary axis) and the electrochemical detector (secondary axis) is shown in <xref rid="F7" ref-type="fig">Figure 7</xref> (the raw data from the electrochemical detector is shown in <xref rid="SD1" ref-type="supplementary-material">Figure S7A</xref>).</p><p id="P35">A small amount of HCN permeated through the carbon bed throughout the test as indicated by the diffuse reflectance configuration sensor. Small amounts of breakthrough commonly occurs during canister testing and may be due to low amounts of vapor permeating through the channels of the irregular carbon granules (common in high-flow canister testing) or the formation of chemical byproducts (e.g., cyanogen). However, an increase in the F(R) slope near 120 min is apparent and corresponds to canister breakthrough detected by the electrochemical detector near this time. A comparison of the first derivatives of the F(R) response at 583 nm and electrochemical response (raw data) shows that the start of breakthrough correlated well for both detectors with both sensors showing a change in slope, i.e., imminent breakthrough near 90 min (<xref rid="SD1" ref-type="supplementary-material">Figure S7B</xref>).</p><p id="P36">The &#x00394;F(R) spectra at <italic toggle="yes">t</italic> = 0, 15, 30, 60, 105 min, and at the end of the test (164 min) are shown in <xref rid="F8" ref-type="fig">Figure 8A</xref>. Distinctive spectral shifts for dicyanocobinamide are readily observed. The final concentration of HCN was &#x0223c;1 ppm before the test was terminated (described in the <xref rid="SD1" ref-type="supplementary-material">Supporting Information</xref>). A small increase near 545 nm is observed along with less pronounced response from 450&#x02013;500 nm compared to direct exposure of Cbi to HCN (expanded inset of <xref rid="F8" ref-type="fig">Figure 8A</xref>). This difference could be due to generation of cyanogen [(CN)<sub>2</sub>], an intermediate and/or byproduct of HCN removal by activated carbon.<sup><xref rid="R18" ref-type="bibr">18</xref></sup> Cyanogen is generated by oxidation of HCN in the presence of copper, a common impregnant in CBRN activated carbon.</p><p id="P37">The average Cbi F(R) spectrum after 10 min of 5.0 ppm (CN)<sub>2</sub> exposure and after 15 min of 5.0 ppm of HCN exposure are shown in <xref rid="F8" ref-type="fig">Figure 8B</xref> (<italic toggle="yes">n</italic> = 3). When Cbi is exposed to (CN)<sub>2</sub>, the distinctive dicyanocobinamide isosbestic point at 531 nm is not observed; however, the small increase near 545 nm observed during canister breakthrough experiments is apparent and the peak F(R) is slightly blue-shifted to shorter wavelengths (&#x0223c;568 nm), compared to 583 nm for exposure to HCN. Limited data are available for Cbi reaction with cyanogen. Because the absorbance spectrum of Cbi is dependent on the properties of the axial ligands to Cbi, the shift to shorter wavelengths may be due to the more electronegative donor ligand which tend to shift the peaks to shorter wavelengths.<sup><xref rid="R19" ref-type="bibr">19</xref></sup> The breakthrough data suggest that Cbi can detect small amounts of cyanogen produced as a byproduct of HCN exposure to a respirator canister. This additive detection is important as the NIOSH REL of HCN is a summation of HCN and (CN)<sub>2</sub>.</p></sec><sec id="S17"><title>HCN Canister Breakthrough Experiments: Diffuse Reflectance Configuration vs RGB Color Sensor.</title><p id="P38">The RGB sensor was placed adjacent to the diffuse reflectance configuration test holder so that HCN breakthrough downstream of the respirator canister was detected simultaneously for both sensor configurations. &#x00394;<italic toggle="yes">C</italic> (secondar<italic toggle="yes">y</italic>-axis) of the RGB color sensor compared with the diffuse reflectance fiber optic configuration (&#x00394;<italic toggle="yes">F</italic>(R), primary axis) is shown in <xref rid="F9" ref-type="fig">Figure 9</xref>. The response for both sensors correlate well upon breakthrough of HCN.</p><p id="P39">At &#x0223c;115 min, a change in slope is observed for both Cbi sensors. Similar to the diffuse reflectance configuration, the RGB sensor responds to low concentrations of HCN permeating through the canister as designated by the increase in &#x00394;<italic toggle="yes">C</italic> prior to breakthrough. The cumulative response may cause a premature end-of-service life warning signal to a respirator user; thus more experiments are required to either lower the sensitivity or include an increased threshold. However, unrealistically high concentrations of HCN (i.e., 1000 ppm) were exposed to canisters during these breakthrough experiments (as per NIOSH testing protocols), so a minimized presence of HCN prior to breakthrough would be expected.</p><p id="P40">Other relevant gaseous species that bind to Cbi include hydrogen sulfide, ammonia, and nitric oxide. However, these species cause a spectral shift at wavelengths differently than the distinct spectral peak at 583 nm upon CN<sup>&#x02212;</sup> binding to Cbi.<sup><xref rid="R5" ref-type="bibr">5</xref>,<xref rid="R14" ref-type="bibr">14</xref>,<xref rid="R19" ref-type="bibr">19</xref></sup> Noncharged species (e.g., ethanol, toluene) bind poorly to cobinamide with spectral shifts dissimilar than the one at 583 nm; thus these species were not assessed in this proof-of-concept study, but will be further explored.<sup><xref rid="R19" ref-type="bibr">19</xref></sup></p></sec></sec><sec id="S18"><title>CONCLUSION</title><p id="P41">An RGB color sensor is a promising low-power and inexpensive ESLI configuration to detect imminent breakthrough of a respirator. The amount of Cbi necessary to generate a color difference upon HCN exposure costs less than a penny per sample (assuming &#x0223c;$1/mg Cbi). The RGB photodiodes demonstrated, in real-time, a rapid change in the red, green, and blue values of the CN(H<sub>2</sub>O)Cbi compound on filter paper upon exposure to HCN at various concentrations and %RH levels. Total &#x00394;<italic toggle="yes">C</italic> from initial CN(H<sub>2</sub>O)Cbi on filter paper was calculated in real-time and yielded values that increased as a function of HCN concentration and %RH, where faster reaction kinetics may be attributed at higher %RH. Effects of temperature will be explored in future studies. Using the total &#x00394;<italic toggle="yes">C</italic> values for each individual paper sensor decreases the variability between paper sensors. The RGB color sensor and associated electronics can be further miniaturized including use of microprocessing chips and Bluetooth technology. The RGB sensor also shows potential to detect low concentrations (ppb) of HCN and (CN)<sub>2</sub> through a respirator canister that correlated well with both a previously used fiber optic diffuse reflectance configuration and an HCN-specific electrochemical detector. The color sensor offers an economical and quantitative approach to determine color-change of an end-of-service-life indicator and shows proof-of-concept for the first HCN ESLI.</p></sec><sec sec-type="supplementary-material" id="SM1"><title>Supplementary Material</title><supplementary-material id="SD1" position="float" content-type="local-data"><label>Development of an Inexpensive RGB Color Sensor for the Detection of Hydrogen Cyanide Gas(NIHMS1880413)_SupplementalInformation</label><media xlink:href="NIHMS1880413-supplement-Development_of_an_Inexpensive_RGB_Color_Sensor_for_the_Detection_of_Hydrogen_Cyanide_Gas_NIHMS1880413__SupplementalInformation.pdf" id="d64e1048" position="anchor"/></supplementary-material><supplementary-material id="SD2" position="float" content-type="local-data"><label>2</label><media xlink:href="NIHMS1880413-supplement-2.pdf" id="d64e1051" position="anchor"/></supplementary-material></sec></body><back><ack id="S19"><title>ACKNOWLEDGMENTS</title><p id="P42">The authors acknowledge financial support from CDC, NIOSH NPPTL, and from the Office of the Director of NIH, and NINDS Grant #U01 NS058030 for the funding of this project. First author would like to acknowledge Drs. Nicole Fry, Dr. Michael Sailor, and Dr. Harry Finklea for insightful discussions that were essential to this manuscript. Author would also like to acknowledge Bradley Newbraugh (CDC, NIOSH DSR) for his assistance with the RGB color sensor electronic connections.</p></ack><fn-group><fn id="FN3"><p id="P43">The findings and conclusions in this report are those of the authors and do not necessarily represent the views of the National Institute for Occupational Safety and Health. Mention of product name does not constitute endorsement by the National Institute for Occupational Safety and Health or the Centers for Disease Control and Prevention.</p></fn><fn fn-type="COI-statement" id="FN4"><p id="P44">The authors declare no competing financial interest.</p></fn></fn-group><glossary><title>ABBREVIATIONS</title><def-list><def-item><term>NIOSH</term><def><p id="P45">National Institute for Occupational Safety and Health</p></def></def-item><def-item><term>AESLI</term><def><p id="P46">active end-of-service-life indicator</p></def></def-item><def-item><term>LED</term><def><p id="P47">light emitting diode</p></def></def-item><def-item><term>ESLI</term><def><p id="P48">end-of-service-life indicator</p></def></def-item><def-item><term>HCN</term><def><p id="P49">hydrogen cyanide</p></def></def-item><def-item><term>H<sub>2</sub>S</term><def><p id="P50">hydrogen sulfide</p></def></def-item><def-item><term>R</term><def><p id="P51">red</p></def></def-item><def-item><term>G</term><def><p id="P52">green</p></def></def-item><def-item><term>B</term><def><p id="P53">blue</p></def></def-item><def-item><term>REL</term><def><p id="P54">recommended exposure limit</p></def></def-item><def-item><term>ppm</term><def><p id="P55">parts-per-million</p></def></def-item><def-item><term>Cbi</term><def><p id="P56">cobinamide</p></def></def-item><def-item><term>CN<sup>&#x02212;</sup></term><def><p id="P57">cyanide ion</p></def></def-item><def-item><term>SD</term><def><p id="P58">standard deviation</p></def></def-item><def-item><term>% RSD</term><def><p id="P59">percent relative standard deviation</p></def></def-item><def-item><term>CI</term><def><p id="P60">confidence interval</p></def></def-item><def-item><term>D.V.</term><def><p id="P61">digital value</p></def></def-item><def-item><term>MFC</term><def><p id="P62">mass flow controller</p></def></def-item><def-item><term>LPM</term><def><p id="P63">liters per minute</p></def></def-item><def-item><term>NPPTL</term><def><p id="P64">National Personal Protective Technology Laboratory</p></def></def-item><def-item><term>CBRN</term><def><p id="P65">chemical, biological, radiological, nuclear</p></def></def-item><def-item><term>F(R)</term><def><p id="P66">diffuse reflectance</p></def></def-item></def-list></glossary><ref-list><title>REFERENCES</title><ref id="R1"><label>(1)</label><mixed-citation publication-type="webpage"><collab>CDC</collab>
<source>End-of-Service-Life</source>
<comment><ext-link xlink:href="http://www.cdc.gov/niosh/npptl/topics/respirators/disp_part/RespSource3end.html" ext-link-type="uri">http://www.cdc.gov/niosh/npptl/topics/respirators/disp_part/RespSource3end.html</ext-link></comment> (<comment>accessed</comment>
<date-in-citation>05/08/2015</date-in-citation>).</mixed-citation></ref><ref id="R2"><label>(2)</label><mixed-citation publication-type="book"><name><surname>Rose-Pehrsson</surname><given-names>S</given-names></name>; <name><surname>Williams</surname><given-names>ML</given-names></name>
<source>Integration of Sensor Technologies in Respirator Vapor Cartridges as End-of-Service Life Indicators: Literature and Manufacturers Review and Research Roadmap</source>; <year>2005</year>.</mixed-citation></ref><ref id="R3"><label>(3)</label><mixed-citation publication-type="webpage"><source>3M Worker Health &#x00026; Safety</source>
<comment><ext-link xlink:href="http://www.3m.com/3M/en_US/worker-health-safety-us/personal-protective-equipment/organic-vapor-cartridge/" ext-link-type="uri">http://www.3m.com/3M/en_US/worker-health-safety-us/personal-protective-equipment/organic-vapor-cartridge/</ext-link></comment> (<comment>accessed</comment>
<month>07</month>/<day>20</day>).</mixed-citation></ref><ref id="R4"><label>(4)</label><mixed-citation publication-type="journal"><name><surname>Greenawald</surname><given-names>LA</given-names></name>; <name><surname>Snyder</surname><given-names>JL</given-names></name>; <name><surname>Fry</surname><given-names>NL</given-names></name>; <name><surname>Sailor</surname><given-names>MJ</given-names></name>; <name><surname>Boss</surname><given-names>GR</given-names></name>; <name><surname>Finklea</surname><given-names>HO</given-names></name>; <name><surname>Bell</surname><given-names>S</given-names></name>
<article-title>Development of a Cobinamide-Based End-of-Service-Life Indicator for Detection of Hydrogen Cyanide Gas.</article-title>
<source>Sens. Actuators, B</source>
<year>2015</year>, <volume>221</volume>, <fpage>379</fpage>&#x02013;<lpage>385</lpage>.</mixed-citation></ref><ref id="R5"><label>(5)</label><mixed-citation publication-type="journal"><name><surname>Greenawald</surname><given-names>LA</given-names></name>; <name><surname>Boss</surname><given-names>GR</given-names></name>; <name><surname>Reeder</surname><given-names>A</given-names></name>; <name><surname>Bell</surname><given-names>S</given-names></name>
<article-title>Development of a hydrogen sulfide end-of-service-life indicator for respirator cartridges using cobinamide.</article-title>
<source>Sens. Actuators, B</source>
<year>2016</year>, <volume>230</volume>, <fpage>658</fpage>&#x02013;<lpage>666</lpage>.</mixed-citation></ref><ref id="R6"><label>(6)</label><mixed-citation publication-type="book"><name><surname>Puiu</surname><given-names>PD</given-names></name>
<part-title>Optical Nano-and Microsystems for Bioanalytics.</part-title> In <source>Springer Series on Chemical Sensors and Biosensors</source>, <name><surname>Urban</surname><given-names>G</given-names></name>, Ed.; <publisher-name>Springer</publisher-name>: <publisher-loc>Berlin</publisher-loc>, <year>2012</year>; Vol. <volume>10</volume>, pp <fpage>3</fpage>&#x02013;<lpage>47</lpage>.</mixed-citation></ref><ref id="R7"><label>(7)</label><mixed-citation publication-type="book"><name><surname>de la Torre</surname><given-names>C</given-names></name>; <name><surname>Mu&#x000f1;iz</surname><given-names>R</given-names></name>; <name><surname>Pe&#x00155;ez</surname><given-names>MA</given-names></name>
<source>A New, Lost-Cost, On-Line RGB Colorimeter for Wine Industry Based on Optical Fibers</source> In <publisher-name>XIX IMEKO World Congress</publisher-name>, <publisher-loc>Portugal</publisher-loc>, <year>2009</year>; pp <fpage>2554</fpage>&#x02013;<lpage>2558</lpage>.</mixed-citation></ref><ref id="R8"><label>(8)</label><mixed-citation publication-type="journal"><name><surname>Janzen</surname><given-names>MC</given-names></name>; <name><surname>Ponder</surname><given-names>JB</given-names></name>; <name><surname>Bailey</surname><given-names>DP</given-names></name>; <name><surname>Ingison</surname><given-names>CK</given-names></name>; <name><surname>Suslick</surname><given-names>KS</given-names></name>
<article-title>Colorimetric Sensor Arrays for Volatile Organic Compounds.</article-title>
<source>Anal. Chem</source>
<year>2006</year>, <volume>78</volume>, <fpage>3591</fpage>&#x02013;<lpage>3600</lpage>.<pub-id pub-id-type="pmid">16737212</pub-id></mixed-citation></ref><ref id="R9"><label>(9)</label><mixed-citation publication-type="journal"><name><surname>Soga</surname><given-names>T</given-names></name>; <name><surname>Jimbo</surname><given-names>Y</given-names></name>; <name><surname>Suzuki</surname><given-names>K</given-names></name>; <name><surname>Citterio</surname><given-names>D</given-names></name>
<article-title>Inkjet-Printed Paper-Based Colorimetric Sensor Array for the Discrimination of Volatile Primary Amines.</article-title>
<source>Anal. Chem</source>
<year>2013</year>, <volume>85</volume>, <fpage>8973</fpage>&#x02013;<lpage>8978</lpage>.<pub-id pub-id-type="pmid">24044503</pub-id></mixed-citation></ref><ref id="R10"><label>(10)</label><mixed-citation publication-type="journal"><name><surname>Eaidkong</surname><given-names>T</given-names></name>; <name><surname>Mungkarndee</surname><given-names>R</given-names></name>; <name><surname>Phollookin</surname><given-names>C</given-names></name>; <name><surname>Tumcharern</surname><given-names>G</given-names></name>; <name><surname>Sukwattanasinitt</surname><given-names>M</given-names></name>; <name><surname>Wacharasindhu</surname><given-names>S</given-names></name>
<article-title>Polydiacetylene paper-based colorimetric sensor array for vapor phase detection and identification of volatile organic compounds.</article-title>
<source>J. Mater. Chem</source>
<year>2012</year>, <volume>22</volume> (<issue>13</issue>), <fpage>5970</fpage>&#x02013;<lpage>5977</lpage>.</mixed-citation></ref><ref id="R11"><label>(11)</label><mixed-citation publication-type="journal"><name><surname>Brenner</surname><given-names>M</given-names></name>; <name><surname>Mahon</surname><given-names>SB</given-names></name>; <name><surname>Lee</surname><given-names>J</given-names></name>; <name><surname>Kim</surname><given-names>J</given-names></name>; <name><surname>Mukai</surname><given-names>D</given-names></name>; <name><surname>Goodman</surname><given-names>S</given-names></name>; <name><surname>Kreuter</surname><given-names>KA</given-names></name>; <name><surname>Ahdout</surname><given-names>R</given-names></name>; <name><surname>Mohammad</surname><given-names>O</given-names></name>; <name><surname>Sharma</surname><given-names>VS</given-names></name>; <name><surname>Blackledge</surname><given-names>W</given-names></name>; <name><surname>Boss</surname><given-names>GR</given-names></name>
<article-title>Comparison of Cobinamide to Hyroxocobalamin in Reversing Cyanide Physiologic Effects in Rabbits using Diffuse Optical Spectroscopy Monitoring.</article-title>
<source>Journal of Biomedical Optics</source>
<year>2010</year>, <volume>15</volume>, <fpage>017001</fpage>.<pub-id pub-id-type="pmid">20210475</pub-id></mixed-citation></ref><ref id="R12"><label>(12)</label><mixed-citation publication-type="journal"><name><surname>Ma</surname><given-names>J</given-names></name>; <name><surname>Dasgupta</surname><given-names>P</given-names></name>; <name><surname>Zelder</surname><given-names>FH</given-names></name>; <name><surname>Boss</surname><given-names>GR</given-names></name>
<article-title>Cobinamide Chemistries for Photometric Cyanide Determination. A Merging Zone Liquid Core Wavequide Cyanide Analyzer Using Cyanoaquacobinamide.</article-title>
<source>Anal. Chim. Acta</source>
<year>2012</year>, <volume>736</volume>, <fpage>78</fpage>&#x02013;<lpage>84</lpage>.<pub-id pub-id-type="pmid">22769008</pub-id></mixed-citation></ref><ref id="R13"><label>(13)</label><mixed-citation publication-type="journal"><name><surname>Baldwin</surname><given-names>DA</given-names></name>; <name><surname>Betterton</surname><given-names>EA</given-names></name>; <name><surname>Pratt</surname><given-names>JM</given-names></name>
<article-title>The Chemistry of Vitamin B12. Part 20. Diaquocobinamide: pKa Values and Evidence for Conformatinal Isomers.</article-title>
<source>J. Chem. Soc., Dalton Trans</source>
<year>1983</year>, <fpage>217</fpage>&#x02013;<lpage>223</lpage>.</mixed-citation></ref><ref id="R14"><label>(14)</label><mixed-citation publication-type="journal"><name><surname>Broderick</surname><given-names>KE</given-names></name>; <name><surname>Singh</surname><given-names>V</given-names></name>; <name><surname>Zhuang</surname><given-names>S</given-names></name>; <name><surname>Kambo</surname><given-names>A</given-names></name>; <name><surname>Chen</surname><given-names>JC</given-names></name>; <name><surname>Sharma</surname><given-names>VS</given-names></name>; <name><surname>Pilz</surname><given-names>RB</given-names></name>; <name><surname>Boss</surname><given-names>GR</given-names></name>
<article-title>Nitric Oxide Scavenging by the Cobalamin Precursor Cobinamide.</article-title>
<source>J. Biol. Chem</source>
<year>2005</year>, <volume>280</volume>, <fpage>8678</fpage>&#x02013;<lpage>8686</lpage>.<pub-id pub-id-type="pmid">15632180</pub-id></mixed-citation></ref><ref id="R15"><label>(15)</label><mixed-citation publication-type="journal"><name><surname>Ford</surname><given-names>SH</given-names></name>; <name><surname>Nichols</surname><given-names>A</given-names></name>; <name><surname>Shambee</surname><given-names>M</given-names></name>
<article-title>The Preparation and Characterization of the diaquo- Forms of Several Incomplete Corrinoids Cobyric Acid, Cobinamide, and Three Isomeric Cibinic Acid Pentaamines.</article-title>
<source>J. Inorg. Biochem</source>
<year>1991</year>, <volume>41</volume>, <fpage>235</fpage>&#x02013;<lpage>244</lpage>.<pub-id pub-id-type="pmid">2056308</pub-id></mixed-citation></ref><ref id="R16"><label>(16)</label><mixed-citation publication-type="webpage"><collab>Adafruit</collab>. <source>Overview of Adafruit TCS34725</source>; <comment><ext-link xlink:href="https://learn.adafruit.com/adafruit-color-sensors/overview" ext-link-type="uri">https://learn.adafruit.com/adafruit-color-sensors/overview</ext-link></comment> (<comment>accessed</comment>
<date-in-citation>07/31/2015</date-in-citation>).</mixed-citation></ref><ref id="R17"><label>(17)</label><mixed-citation publication-type="book"><collab>NIOSH</collab>, <source>Determination of CBRN Acid Gases (Hydrogen Cyanide) Service Life Test, Air-Purifying Respirators Standard Test Procedure (STP)</source>
<publisher-name>NPPTL</publisher-name>: <publisher-loc>Pittsburgh</publisher-loc>, <year>2005</year>.</mixed-citation></ref><ref id="R18"><label>(18)</label><mixed-citation publication-type="journal"><name><surname>Alves</surname><given-names>BR</given-names></name>; <name><surname>Clark</surname><given-names>AJ</given-names></name>
<article-title>An Examination of the Products Formed on Reaction of Hydrogen Cyanide and Cyanogen with Copper, Chromium (6+) and Copper-Chromium (6+) Impregnated Activated Carbons.</article-title>
<source>Carbon</source>
<year>1986</year>, <volume>24</volume> (<issue>3</issue>), <fpage>287</fpage>&#x02013;<lpage>294</lpage>.</mixed-citation></ref><ref id="R19"><label>(19)</label><mixed-citation publication-type="book"><name><surname>Pratt</surname><given-names>JM</given-names></name>
<source>Inorganic Chemistry of Vitamin B<sub>12</sub></source>; <publisher-name>Academic Press Inc.</publisher-name>: <publisher-loc>New York</publisher-loc>, <year>1972</year>.</mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Figure 1.</label><caption><p id="P67">(A) Top view of RGB color sensor in holder. (B) Expanded view of sensor chip.</p></caption><graphic xlink:href="nihms-1880413-f0002" position="float"/></fig><fig position="float" id="F2"><label>Figure 2.</label><caption><p id="P68">(A) Absorption spectra of three Cbi complexes&#x02014;20.0 <italic toggle="yes">&#x003bc;</italic>M OH(H<sub>2</sub>O)Cbi (solid line), 20.0 <italic toggle="yes">&#x003bc;</italic>M CN(H<sub>2</sub>O)Cbi (dotted line), and 20.0 <italic toggle="yes">&#x003bc;</italic>M (CN)<sub>2</sub>Cbi (dashed line).<sup><xref rid="R4" ref-type="bibr">4</xref></sup> (B) Diffuse reflectance spectra (plotted using the Kubelka&#x02013;Munk function) of monocyanocobinamide on glass fiber paper before and after exposure to HCN. Part A reprinted with permission from ref <xref rid="R4" ref-type="bibr">4</xref>. Copyright 2015, Elsevier.</p></caption><graphic xlink:href="nihms-1880413-f0003" position="float"/></fig><fig position="float" id="F3"><label>Figure 3.</label><caption><p id="P69">Response of the separate &#x00394;<italic toggle="yes">R</italic> (dotted line), &#x00394;<italic toggle="yes">G</italic> (dashed line), and &#x00394;<italic toggle="yes">B</italic> (solid line) values (D.V.) on exposure of CN(H<sub>2</sub>O)Cbi-impregnated filter paper to 5.0 ppm of HCN at 25%RH.</p></caption><graphic xlink:href="nihms-1880413-f0004" position="float"/></fig><fig position="float" id="F4"><label>Figure 4.</label><caption><p id="P70">(A) Total &#x00394;<italic toggle="yes">C</italic> during HCN exposure of CN(H<sub>2</sub>O)Cbi-impregnated filter paper at 25%RH&#x02013;Blank (solid line), 1.0 ppm (crossed line), 3.0 ppm (circle line), 5.0 ppm (triangle line), 10.0 ppm of HCN (square line). (B) Expanded view of initial response (60 s). (C) CN(H<sub>2</sub>O)Cbi on glass fiber filter paper after 10.0 ppm of HCN exposure with chip LED on and (D) before HCN exposure.</p></caption><graphic xlink:href="nihms-1880413-f0005" position="float"/></fig><fig position="float" id="F5"><label>Figure 5.</label><caption><p id="P71">(A) Response of the separate &#x00394;<italic toggle="yes">R</italic> (dotted line), &#x00394;<italic toggle="yes">G</italic> (dashed line), and &#x00394;<italic toggle="yes">B</italic> (solid line) values (D.V.) upon 5.0 ppm of HCN exposure to the CN(H<sub>2</sub>O)Cbi-impregnated filter paper at 85%RH. (B) RGB color sensor total &#x00394;<italic toggle="yes">C</italic> during HCN exposure at 85%RH.</p></caption><graphic xlink:href="nihms-1880413-f0006" position="float"/></fig><fig position="float" id="F6"><label>Figure 6.</label><caption><p id="P72">Average total &#x00394;<italic toggle="yes">C</italic> during 5.0 ppm of HCN exposure to the CN(H<sub>2</sub>O)Cbi-impregnated filter paper at various %RH; HCN was cycled on and off (<italic toggle="yes">n</italic> = 3).</p></caption><graphic xlink:href="nihms-1880413-f0007" position="float"/></fig><fig position="float" id="F7"><label>Figure 7.</label><caption><p id="P73">Breakthrough curves for Cbi paper sensor at 583 nm (solid line) and electrochemical detector (dotted line; plotted as 10-point moving average). An average Cbi F(R) response of 700&#x02013;750 nm is used as reference (not shown).</p></caption><graphic xlink:href="nihms-1880413-f0008" position="float"/></fig><fig position="float" id="F8"><label>Figure 8.</label><caption><p id="P74">(A) &#x00394;<italic toggle="yes">F</italic>(R) spectra during HCN breakthrough experiment. Inset: Expanded view of 450&#x02013;650 nm. (B). Comparison of CN(H<sub>2</sub>O)Cbi on paper when exposed to 5.0 ppm (CN)<sub>2</sub> and 5.0 ppm of HCN (separate experiments).</p></caption><graphic xlink:href="nihms-1880413-f0009" position="float"/></fig><fig position="float" id="F9"><label>Figure 9.</label><caption><p id="P75">CN(H<sub>2</sub>O)Cbi-impregnated filter paper response to HCN breakthrough from a respirator canister using the RGB color sensor (square markers) compared to with the diffuse reflectance sensor configuration (diamond markers).</p></caption><graphic xlink:href="nihms-1880413-f0010" position="float"/></fig></floats-group></article>