<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.3 20210610//EN" "JATS-archivearticle1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">0261412</journal-id><journal-id journal-id-type="pubmed-jr-id">20783</journal-id><journal-id journal-id-type="nlm-ta">Appl Ergon</journal-id><journal-id journal-id-type="iso-abbrev">Appl Ergon</journal-id><journal-title-group><journal-title>Applied ergonomics</journal-title></journal-title-group><issn pub-type="ppub">0003-6870</issn><issn pub-type="epub">1872-9126</issn></journal-meta><article-meta><article-id pub-id-type="pmid">26674410</article-id><article-id pub-id-type="pmc">9774999</article-id><article-id pub-id-type="doi">10.1016/j.apergo.2015.09.007</article-id><article-id pub-id-type="manuscript">HHSPA1856050</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Evaluation of four sensor locations for physical activity assessment</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Schall</surname><given-names>Mark C.</given-names><suffix>Jr.</suffix></name><xref rid="A1" ref-type="aff">a</xref></contrib><contrib contrib-type="author"><name><surname>Fethke</surname><given-names>Nathan B.</given-names></name><xref rid="A2" ref-type="aff">b</xref></contrib><contrib contrib-type="author"><name><surname>Chen</surname><given-names>Howard</given-names></name><xref rid="A2" ref-type="aff">b</xref></contrib></contrib-group><aff id="A1"><label>a</label>Department of Industrial and Systems Engineering, Auburn University, Auburn, AL</aff><aff id="A2"><label>b</label>Department of Occupational and Environmental Health, University of Iowa, Iowa City, IA</aff><pub-date pub-type="nihms-submitted"><day>10</day><month>12</month><year>2022</year></pub-date><pub-date pub-type="ppub"><month>3</month><year>2016</year></pub-date><pub-date pub-type="epub"><day>29</day><month>9</month><year>2015</year></pub-date><pub-date pub-type="pmc-release"><day>22</day><month>12</month><year>2022</year></pub-date><volume>53</volume><issue>Pt A</issue><fpage>103</fpage><lpage>109</lpage><abstract id="ABS1"><p id="P1">Direct measurements of physical activity (PA) obtained with inertial measurement units (IMUs) secured to the upper arms and trunk of 36 registered nurses working a full shift were compared to measurements obtained with a commercially-available PA monitor (ActiGraph wGT3X-BT) worn at the waist. Raw accelerations from each device were summarized into PA counts/min and metabolic equivalent (METs) categories using standard definitions. Differences between measurements were examined using repeated measures one-way analyses of variance (ANOVA) and agreement was assessed using Bland-Altman plots. Statistically significant differences were observed between all sensor locations for all PA summary metrics except for between the left and right arm for percentages of work time in the light and moderate counts/min categories. Bland-Altman plots suggested limited agreement between measurements obtained with the IMUs and measurements obtained with the wGT3X-BT waist-worn PA monitor. Results indicate that PA measurements vary substantially based on sensor location.</p></abstract><kwd-group><kwd>musculoskeletal disorders</kwd><kwd>posture</kwd><kwd>physical activity</kwd><kwd>accelerometer</kwd><kwd>low back</kwd><kwd>shoulder</kwd></kwd-group></article-meta></front><body><sec id="S1"><label>1.</label><title>Introduction</title><p id="P2">Musculoskeletal health outcomes of the low back and neck/shoulder are among the most prevalent and burdensome of all occupational injuries. Estimates from the Global Burden of Disease 2010 study suggest that low back pain causes more global disability than any other condition, accounting for 83 million disability-adjusted life years (DALYs) in 2010 alone (<xref rid="R35" ref-type="bibr">Hoy et al., 2012</xref>; <xref rid="R36" ref-type="bibr">Hoy et al., 2014a</xref>). Low back pain arising from occupational exposure to physical risk factors caused 21.7 million DALYs; an increase of 22% between 1990 and 2010 (<xref rid="R16" ref-type="bibr">Driscoll et al., 2014</xref>; <xref rid="R53" ref-type="bibr">Murray et al., 2013</xref>). Neck/shoulder pain was estimated to account for 33.6 million DALYs in 2010, ranking it the 4<sup>th</sup> highest in terms of disability and 21<sup>st</sup> in terms of overall burden (<xref rid="R37" ref-type="bibr">Hoy et al., 2014b</xref>).</p><p id="P3">Occupational exposure to non-neutral postures has been associated with musculoskeletal health outcomes of the low back and neck/shoulder (<xref rid="R14" ref-type="bibr">da Costa and Vieira, 2010</xref> ; <xref rid="R75" ref-type="bibr">van Rijn et al., 2010</xref>; <xref rid="R78" ref-type="bibr">Vieira and Kumar, 2004</xref>). Methods for assessing exposure to non-neutral working postures in a field setting include self-report, observational, and direct measurement (<xref rid="R11" ref-type="bibr">Burdorf and Van Der Beek, 1999</xref>; <xref rid="R15" ref-type="bibr">David, 2005</xref>). The standard approach for directly measuring occupational exposure to non-neutral postures of the low back and shoulder is with piezoresistive accelerometers or, more recently, inertial measurement units (IMUs) secured to the trunk and/or upper arms (<xref rid="R15" ref-type="bibr">David, 2005</xref>; <xref rid="R46" ref-type="bibr">Li and Buckle, 1999</xref>; <xref rid="R67" ref-type="bibr">Teschke et al., 2009</xref>).</p><p id="P4">An IMU is a solid-state device that measures and reports an object&#x02019;s spatial orientation and motion characteristics using multiple electromechanical sensors (i.e., accelerometers, gyroscopes, and/or magnetometers). They are considered advantageous to accelerometers for posture assessment as fusion of the components of an IMU may address limitations of each individual sensor component (<xref rid="R48" ref-type="bibr">Luinge and Veltink, 2005</xref>; <xref rid="R57" ref-type="bibr">Roetenberg et al., 2007</xref>). For example, gyroscope measurements can be used to compensate for accelerometer-based measurements that are known to be negatively affected by dynamic and complex motions (<xref rid="R2" ref-type="bibr">Amasay et al., 2009</xref>; <xref rid="R21" ref-type="bibr">Godwin et al., 2009</xref>). Several recent studies have indicated that IMUs are reasonably stable and accurate when estimating trunk and upper arm postures in comparison to &#x0201c;gold-standard&#x0201d; optoelectric motion capture systems (<xref rid="R13" ref-type="bibr">Cuesta-Vargas et al., 2010</xref>; <xref rid="R17" ref-type="bibr">El-Gohary and McNames, 2012</xref>; <xref rid="R43" ref-type="bibr">Kim and Nussbaum, 2013</xref>; <xref rid="R58" ref-type="bibr">Schall Jr et al., 2015a</xref>) and a field-capable reference device (<xref rid="R59" ref-type="bibr">Schall Jr et al., 2015b</xref>). Additionally, the small size and increasing affordability of IMUs make them practical instruments for measuring posture in field-based research.</p><p id="P5">In addition to posture, an IMU&#x02019;s accelerometer may be used to measure other aspects of worker health that are typically difficult to observe, such as intensity of physical activity (PA). Although leisure-time PA is widely considered beneficial to overall health (<xref rid="R24" ref-type="bibr">Haskell et al., 2007</xref>; <xref rid="R79" ref-type="bibr">Warburton et al., 2006</xref>), and some studies have observed favorable effects of PA on musculoskeletal pain among worker populations (<xref rid="R29" ref-type="bibr">Hildebrandt et al., 2000</xref>), high intensity occupational PA has been associated with increased risk of several chronic health conditions and may be deleterious to health (<xref rid="R23" ref-type="bibr">Harari et al., 2015</xref>; <xref rid="R26" ref-type="bibr">Heneweer et al., 2011</xref>; <xref rid="R32" ref-type="bibr">Holtermann et al., 2012a</xref>; <xref rid="R33" ref-type="bibr">Holtermann et al., 2012b</xref>; <xref rid="R34" ref-type="bibr">Holtermann et al., 2010</xref>; <xref rid="R63" ref-type="bibr">Sitthipornvorakul et al., 2011</xref>). Moreover, some investigators have suggested a U-shaped relationship between intensity of PA and undesirable health outcomes (i.e. both inactivity and excessive activity may increase risk; <xref rid="R27" ref-type="bibr">Heneweer et al., 2009</xref>; <xref rid="R60" ref-type="bibr">Sesso et al., 2000</xref>). Recent work has thus emphasized the need for more accurate ascertainment of exposure to occupational and leisure-time PA using objective and validated field measurement instruments to better establish future public and occupational health recommendations (<xref rid="R31" ref-type="bibr">Holtermann, 2015</xref>; <xref rid="R56" ref-type="bibr">Prince et al., 2008</xref>).</p><p id="P6">Modern PA monitors are portable, electronic devices used to measure and track fitness-related metrics such as energy expenditure, caloric consumption, sleep patterns, and total activity. PA monitors are commonly used in epidemiological research because of their small size, freedom from biases associated with self-report, and accuracy and precision in estimating intensity of activity (<xref rid="R19" ref-type="bibr">Freedson et al., 2012</xref>; <xref rid="R51" ref-type="bibr">Matthews et al., 2012</xref>). Most PA monitors are worn at the waist or wrist and use single or multi-axis accelerometers to provide summary metrics of the quantity and intensity of movements during set time intervals (<xref rid="R66" ref-type="bibr">Taraldsen et al., 2012</xref>; <xref rid="R69" ref-type="bibr">Troiano et al., 2008</xref>; <xref rid="R74" ref-type="bibr">Van Remoortel et al., 2012</xref>). PA monitors have been used extensively to promote workplace health, with promising results (<xref rid="R8" ref-type="bibr">Bravata et al., 2007</xref>; <xref rid="R18" ref-type="bibr">Freak-Poli et al., 2011</xref>; <xref rid="R55" ref-type="bibr">Pal et al., 2009</xref>; <xref rid="R76" ref-type="bibr">van Sluijs et al., 2006</xref>).</p><p id="P7">Because IMUs and commercially available PA monitors incorporate fundamentally identical hardware (accelerometers), the use of small numbers of sensors in anatomic locations to capture both biomechanically meaningful posture information and PA information may be possible. Commercially available PA monitors positioned on the upper arms and on the upper back provide valid inclination data for direct long-term field measurements of upper arm and trunk inclinations in comparison to a magnetic tracking device (<xref rid="R44" ref-type="bibr">Korsh&#x000f8;j et al., 2014</xref>) and a universal goniometer (<xref rid="R30" ref-type="bibr">Hirschhorn, 2015</xref>). However, the extent to which PA measurements obtained from sensors located on the upper arms or on the trunk agree with PA measurements obtained from PA monitor worn at the waist is not known. The objective of this study was, therefore, to estimate the agreement between measures of PA obtained with IMUs attached to the upper arms and to the trunk and measures of PA obtained with a commercially available PA monitor worn at the waist.</p></sec><sec id="S2"><label>2.</label><title>Methods</title><sec id="S3"><label>2.1.</label><title>Participants and Study Design</title><p id="P8">A convenience sample of 36 healthy, female registered nurses (mean age=30.8 years, SD=10.1; mean body mass index [BMI] =24.1, SD=4.4) was recruited from two medical surgical inpatient units in the University of Iowa Hospitals and Clinics. Participants self-reported 1) no history of physician-diagnosed MSDs in the neck/shoulder or back regions, 2) no neck/shoulder or back pain two weeks prior to enrollment, and 3) no history of neurodegenerative disease (e.g., Parkinson&#x02019;s disease). All participants were right-hand dominant. Study procedures were approved by the University of Iowa Institutional Review Board and the University of Iowa Hospitals and Clinics Nursing Review Committee. Informed consent was obtained prior to participation.</p></sec><sec id="S4"><label>2.2.</label><title>Physical Activity Data Processing</title><p id="P9">Direct measurements of PA from each participant were obtained using three IMUs and one wGT3X-BT PA monitor (ActiGraph, Pensacola, Florida, USA). Each IMU (ArduIMU v3, 3D Robotics Inc., Berkeley, CA) was a small wireless, battery-powered unit that was set to measure and store acceleration (triaxial, +/&#x02212; 8 g) information. One IMU was secured to the posterior trunk at approximately the level of the 4th thoracic vertebral body and one IMU was secured to the lateral aspect of both upper arms approximately one-half the distance between the lateral epicondyle and the acromion (<xref rid="F1" ref-type="fig">Figure 1</xref>). The raw acceleration data streams of the wGT3X-BT (triaxial, +/&#x02212; 8 g) and each IMU were sampled at 50 Hz for a continuous duration of 12 hours. All devices stored the raw acceleration data to on-board flash memory. A combination of custom LabVIEW (version 2014, National Instruments Inc., Austin, TX) and Matlab (r2014a, The Mathworks, Natick, MA) programs were used to synchronize the data from each device (using time stamps recorded with the data) and process the raw acceleration information to PA summary metrics.</p><p id="P10">The raw acceleration information from each IMU and the wGT3X-BT were summarized using two approaches. For the first approach, the raw acceleration information was transformed from units of gravity (i.e., g) to a unitless metric describing the intensity of the acceleration (i.e., &#x0201c;counts&#x0201d;) (<xref rid="R12" ref-type="bibr">Chen and Bassett, 2005</xref>; <xref rid="R39" ref-type="bibr">John and Freedson, 2012</xref>). First, the raw acceleration values were converted into an omnidirectional measure of acceleration by calculating the vector magnitude of the three accelerometer axes. The resulting acceleration signal was then band-pass filtered (zero-phase, 6<sup>th</sup> order Butterworth) at a bandwidth of 0.25 to 2.5 Hz and full-wave rectified (<xref rid="R39" ref-type="bibr">John and Freedson, 2012</xref>). The filtered acceleration signal was then converted to activity counts, defined as any activity that was measured above a predefined threshold of 0.016317 m/s<sup>2</sup> (<xref rid="R3" ref-type="bibr">Arias et al., 2015</xref>; <xref rid="R71" ref-type="bibr">Umukoro et al., 2013</xref>). The counts at each data sample were summed across non-overlapping epochs of 1-min in duration, providing results in terms of counts/min. Finally, the counts/min at each epoch was categorized into different intensities of PA. We used definitions from <xref rid="R20" ref-type="bibr">Freedson et al. (1998)</xref> to categorize PA as &#x0201c;sedentary&#x0201d; (0-100 counts/min), &#x0201c;light&#x0201d; (101-1952 counts/min), &#x0201c;moderate&#x0201d; (1953-5724 counts/min), vigorous (5725-9498 counts/min), and &#x0201c;very vigorous&#x0201d; (&#x0003e;9498 counts/min). For each participant and sensor, we then computed the total number of minutes assigned to each PA category across the full sampling duration.</p><p id="P11">For the second approach, the raw acceleration information was transformed to reflect metabolic equivalents (METs) expressing the energy cost of physical activities following the recommendations of <xref rid="R28" ref-type="bibr">Hildebrand et al. (2014)</xref>. Specifically, the raw acceleration values were converted into an omnidirectional measure of acceleration by calculating the vector magnitude of the three accelerometer axes and then subtracting the value of gravity (g), after which, negative values were rounded up to zero. The resulting value has been referred to as the Euclidian norm minus one (ENMO) (<xref rid="R73" ref-type="bibr">van Hees et al., 2013</xref>). Data were then further reduced by calculating the average acceleration values per 1-s epoch and then finding the average of these 1-s epoch values over 1-min intervals. The resulting acceleration averages per 1-min epoch were then used to predict METs based on the relationship between acceleration and oxygen consumption (VO<sub>2</sub>) (<xref rid="R28" ref-type="bibr">Hildebrand et al., 2014</xref>). We used standard definitions to categorize PA as &#x0201c;light&#x0201d; (&#x02264;3.0 METs), &#x0201c;moderate&#x0201d; (&#x0003e;3.0 METs), or &#x0201c;vigorous&#x0201d; (&#x0003e;6.0 METs) intensity activity.</p></sec><sec id="S5"><label>2.3.</label><title>Statistical Analysis</title><p id="P12">Differences between percentages of work time in each PA summary metric category by sensor location (IMUs on the trunk and each upper arm and the wGT3X-BT on the waist) were examined using repeated measures one-way analyses of variance (ANOVA), with device as a fixed effect. A separate analysis was performed for each PA category, and post-hoc pairwise comparisons were performed using a Bonferroni correction.</p><p id="P13">Agreement between the counts/min and METs obtained by the IMUs and the wGT3X-BT was also assessed using Bland-Altman analyses (<xref rid="R7" ref-type="bibr">Bland and Altman, 2007</xref>). Specifically, for each epoch, we calculated the average of the IMU and wGT3X-BT measurements and the difference between the IMU and wGT3X-BT measurements. Estimates of the mean (fixed) bias of the IMU measurement in comparison to the wGT3X-BT measurement and upper and lower limits of agreement were obtained using calculations that considered both repeated measures and a time-varying &#x0201c;true&#x0201d; value of the measurement (<xref rid="R7" ref-type="bibr">Bland and Altman, 2007</xref>).</p><p id="P14">Due to the large number of 1-min epochs in the data set (36 participants &#x000d7; 720 1-min epochs = 25,920 total epochs), a &#x0201c;summarized&#x0201d; Bland-Altman plot was also developed to qualitatively assess inter-method agreement. Specifically, across all epochs for each participant, we calculated the mean and standard deviation of the average of the IMU and the wGT3X-BT measurements and the mean and standard deviation of the differences between the IMU and the wGT3X-BT measurements. We then plotted the means of the differences against the means of the averages and assessed the strength of the linear relationship between the means of the averages and the means of the differences using Pearson correlation coefficients. Linear regression lines were fit to check for proportional bias and hyperbolic, 95% prediction limits were plotted around the line of best fit (<xref rid="R4" ref-type="bibr">Armitage et al., 2008</xref>; <xref rid="R47" ref-type="bibr">Ludbrook, 2010</xref>).</p></sec></sec><sec id="S6"><label>3.</label><title>Results</title><p id="P15">Complete ActiGraph data were obtained on all 36 participants. Instrumentation failure (IMUs) led to the loss of one participant&#x02019;s trunk data, three participants&#x02019; left upper arm data, and three participants&#x02019; right upper arm data. All but three participants worked a 12 hour shift (two worked for eight hours and one worked for 11 hours). Twenty-one participants worked day shifts (starting at 7 am) and 15 participants worked night shifts (starting at 7pm). Overall, a small percentage of work time was spent performing moderate PA across all participants regardless of sensor location. On average, participants spent less than 0.25% of their work day performing any vigorous activity (&#x0003e;5725 counts/min or &#x0003e;6 METS). Due to the small percentage of work time spent performing vigorous activity, the percentage of work time spent performing vigorous or very vigorous activity was combined with the percentage of work time performing moderate activity for all analyses.</p><p id="P16">Statistically significant differences were observed between all sensor locations for all PA summary metrics except for between the left and right arm for percentages of work time in the light and moderate counts/min categories (<xref rid="T1" ref-type="table">Table 1</xref>). In general, the IMU worn on the dominant (right) arm displayed the greatest range and mean percentage of work time performing moderate intensity PA, followed by the non-dominant (left) arm, the waist, and the trunk (e.g., percentage of work time METs moderate; <xref rid="F2" ref-type="fig">Figure 2</xref>).</p><p id="P17">Bland-Altman evaluations used to assess agreement between the PA measurements from each IMU and the wGT3X-BT further suggested that PA measurements from the trunk and each upper arm were substantially different (<xref rid="T2" ref-type="table">Table 2</xref>). Mean bias estimates indicated that the IMUs worn on the upper arms both estimated about 200 counts/min more, on average, than the wGT3X-BT (195 counts/min for the left arm and 208 for the right arm). In addition, estimates for the limits of agreement indicated potentially large differences between measurements. The IMU worn on the right (dominant) upper arm had a greater range for the limits of agreement (2229 counts/min) in comparison to that of the left upper arm (1743 counts/min). The IMU worn on the trunk had a smaller mean bias than the upper arm IMUs, estimating about 8 counts/min fewer, on average, than the wGT3X-BT. Despite the smaller mean bias, however, the IMU worn on the trunk displayed the greatest range of the limits of agreement (2581 counts/min). A similar pattern of mean bias and limits of agreement results was observed for METs, although the greatest range of the limits of agreement occurred with the right (dominant) upper arm (1.33 METs) rather than the trunk.</p><p id="P18">Qualitative assessment of the summarized Bland-Altman plots (<xref rid="F3" ref-type="fig">Figure 3</xref>) indicated that, in general, as the mean of the average of two measurement approaches increased, the difference between the measurement approaches also increased. An exception was an observed decrease in the difference in METs between the IMU at the trunk and the wGT3X-BT with an increase in the average METs of these two sensors. Within-subject variability of both the averages of the measurement approaches and the differences between them also generally increased as the average increased. The existence of proportional bias, especially for the upper arms, suggests that PA measurements (i.e., counts/min and METs) from the IMUs at the trunk and upper arms did not agree equally through the full range of measurements with PA measurements from the wGT3X-BT at the waist. This observation was most pronounced when comparing the IMUs on the upper arms with the wGT3X-BT.</p></sec><sec id="S7"><label>4.</label><title>Discussion</title><p id="P19">While participation in moderate- or vigorous-intensity leisure-time PA is considered an important aspect of good overall health (<xref rid="R24" ref-type="bibr">Haskell et al., 2007</xref>; <xref rid="R79" ref-type="bibr">Warburton et al., 2006</xref>), large amounts of both low intensity (i.e., sedentary) and high intensity occupational PA may be detrimental to health (<xref rid="R23" ref-type="bibr">Harari et al., 2015</xref>; <xref rid="R26" ref-type="bibr">Heneweer et al., 2011</xref>; <xref rid="R27" ref-type="bibr">Heneweer et al., 2009</xref>; <xref rid="R32" ref-type="bibr">Holtermann et al., 2012a</xref>; <xref rid="R34" ref-type="bibr">Holtermann et al., 2010</xref>; <xref rid="R63" ref-type="bibr">Sitthipornvorakul et al., 2011</xref>). Further development of objective, field capable measurement devices are needed to more accurately ascertain exposure to occupational and leisure-time PA and understand their relationship with health outcomes (<xref rid="R31" ref-type="bibr">Holtermann, 2015</xref>). Several recent studies and systematic reviews have assessed the validity and/or reliability of PA monitors among participants in controlled laboratory environments and/or during free-living conditions (<xref rid="R1" ref-type="bibr">Aguilar-Far&#x000ed;as et al., 2014</xref>; <xref rid="R9" ref-type="bibr">Brazeau et al., 2014</xref>; <xref rid="R22" ref-type="bibr">Grydeland et al., 2014</xref>; <xref rid="R38" ref-type="bibr">Jarrett et al., 2014</xref>; <xref rid="R41" ref-type="bibr">John et al., 2010</xref>,<xref rid="R40" ref-type="bibr">2013</xref>; <xref rid="R42" ref-type="bibr">Kelly et al., 2013</xref>; <xref rid="R45" ref-type="bibr">Kowalski et al., 2012</xref>; <xref rid="R74" ref-type="bibr">Van Remoortel et al., 2012</xref>; <xref rid="R68" ref-type="bibr">Thiese, 2014</xref>; <xref rid="R77" ref-type="bibr">Vanhelst et al., 2010</xref>; <xref rid="R80" ref-type="bibr">Welk et al., 2012</xref>; <xref rid="R81" ref-type="bibr">Yang and Hsu, 2010</xref>). Results have generally suggested a high level of heterogeneity (<xref rid="R74" ref-type="bibr">Van Remoortel et al., 2012</xref>), indicating a need for researchers to cautiously select monitors and summary metrics that are appropriate for their research questions (<xref rid="R45" ref-type="bibr">Kowalski et al., 2012</xref>). Recommendations and protocols for evaluating and using wearable monitors for researchers, developers, and end users have thus been developed in an effort to control for differences among monitors and summary metrics (<xref rid="R10" ref-type="bibr">Brazendale et al., 2015</xref>; <xref rid="R19" ref-type="bibr">Freedson et al., 2012</xref>; <xref rid="R80" ref-type="bibr">Welk et al., 2012</xref>).</p><p id="P20">IMUs are reasonably stable and accurate instruments capable of simultaneously measuring multiple components of worker health such as exposure to high intensity PA and non-neutral working postures. Despite the large number of studies comparing various PA monitors and activity outcomes, the current study represents the first effort we are aware of to estimate the agreement between measures of PA obtained with IMUs attached to the upper arms and to the trunk to measures of PA obtained with an ActiGraph wGT3X-BT worn at the waist. Overall, results suggested that PA measurements obtained from the four sensor locations evaluated in this study (the waist, trunk, and each upper arm) varied substantially. The IMU worn on the dominant (right) arm displayed the greatest amount of moderate intensity PA for all summary metrics evaluated, followed by the non-dominant (left) arm, the waist, and the trunk.</p><p id="P21">Accelerometers worn on the waist may underestimate the energy expenditure of free-living individuals because of an inability to detect arm movements and upper body work (<xref rid="R5" ref-type="bibr">Bassett Jr et al., 2000</xref>; <xref rid="R25" ref-type="bibr">Hendelman et al., 2000</xref>; <xref rid="R50" ref-type="bibr">Matthews, 2005</xref>; <xref rid="R51" ref-type="bibr">Matthews et al., 2012</xref>). Given this limitation, it is worth considering if PA measurements for individuals performing complex, high intensity upper body activities should be assessed using PA monitors worn on the upper arm instead of the waist. Patient care workers, for example, have been observed to report a substantially greater duration of moderate to vigorous PA during a work week than what is directly measured by PA monitors worn at the waist (<xref rid="R71" ref-type="bibr">Umukoro et al., 2013</xref>). Although nurses may perceive their work as physically-demanding, PA monitors worn at the waist may not be sensitive to the tasks potentially culpable for the sentiment (e.g., extremes of posture during patient transfers). The results of the current study imply that an IMU worn on the upper arm may provide more representative estimates of PA than a waist-worn PA monitor for field-based occupational research. However, while we have observed a greater range and higher percentage of work time performing moderate PA for IMUs located on the upper arms in comparison to the waist-worn PA monitor, it is unknown what specific tasks participants were doing that led to this observation.</p><p id="P22">An additional incentive to wearing PA monitors on the upper arm is the ability to capture information regarding exposure to non-neutral shoulder postures, a risk factor for the development of work-related musculoskeletal health outcomes (<xref rid="R14" ref-type="bibr">da Costa and Vieira, 2010</xref>; <xref rid="R52" ref-type="bibr">Miranda et al., 2001</xref>; <xref rid="R54" ref-type="bibr">Ohlsson et al., 1994</xref>; NIOSH, 1997; <xref rid="R61" ref-type="bibr">Silverstein et al., 2008</xref>; <xref rid="R62" ref-type="bibr">Silverstein et al., 2006</xref>; <xref rid="R64" ref-type="bibr">Svendsen et al., 2004a</xref>; <xref rid="R65" ref-type="bibr">Svendsen et al., 2004b</xref>; <xref rid="R75" ref-type="bibr">van Rijn et al., 2010</xref>; <xref rid="R72" ref-type="bibr">van der Windt et al., 2000</xref>). Estimates of arm and trunk inclination obtained with PA monitors have been observed to compare favorably to estimates from a magnetic tracking device (<xref rid="R44" ref-type="bibr">Korsh&#x000f8;j et al., 2014</xref>) and universal goniometer (<xref rid="R30" ref-type="bibr">Hirschhorn, 2015</xref>). While PA monitors have been used to assess PA levels in the context of worker health promotion (<xref rid="R49" ref-type="bibr">Malik et al., 2014</xref>) and have strong potential for posture measurement, few studies have simultaneously measured occupational exposure to working postures and PA. This study provides a critical step towards understanding the potential limitations of using IMUs worn on the trunk and upper arms to simultaneously measure PA and exposure to non-neutral working postures.</p><p id="P23">Limitations of the study include the lack of a wrist-worn PA monitor and the collection of PA data during a single work shift. Several studies have recommended multiple measurement days for reliable accelerometer estimates of habitual daily PA (<xref rid="R6" ref-type="bibr">Berlin et al., 2006</xref>; <xref rid="R70" ref-type="bibr">Trost et al., 2000</xref>; <xref rid="R80" ref-type="bibr">Welk et al., 2012</xref>). Agreement between sensor locations may have improved had measurements been obtained over multiple days. Additionally, while we used raw acceleration to measure PA and summarized our estimates of PA using two approaches, the use of traditional PA count cut points is becoming less common (<xref rid="R40" ref-type="bibr">John et al., 2013</xref>). Finally, it is important to note that while the IMU worn on the dominant (right) arm displayed greater levels of moderate intensity PA for all summary metrics evaluated, on average, than the non-dominant (left) arm, it is unknown if this result was a function of worker handedness or if the work itself required more right arm movement. Further research on the effects of worker handedness and the design of the work environment on PA estimation is needed.</p></sec><sec id="S8"><label>5.</label><title>Conclusions</title><p id="P24">Efficient estimation of the physical demands of work remains somewhat limited by the need for multiple sensors to capture different aspects of physical demands (e.g., ActiGraph or other commercially available monitors to capture PA and a separate accelerometer or IMU to measure posture). The results of this study indicate that the location of the sensor used to obtain acceleration information may substantially affect PA estimates when compared to estimates from a waist-worn PA monitor. Additional research is needed to better understand how PA measurements obtained from the upper arm and trunk relates to measurements obtained from waist and wrist-worn PA monitors. Specifically, validation studies conducted in controlled laboratory environments or using systematic observation of field-based activities are needed to develop conversion algorithms intended to relate or synthesize PA estimates from various studies (e.g., <xref rid="R10" ref-type="bibr">Brazendale et al., 2015</xref>). Standardized, non-proprietary metrics and procedures for using ambulatory sensors such as IMUs in field-based research must also continue to be developed and evaluated (<xref rid="R19" ref-type="bibr">Freedson et al., 2012</xref>).</p><p id="P25">While PA measurements obtained from the upper arm and trunk may not agree with measurements obtained from the waist, they may provide more representative PA estimates for demanding work tasks than a waist-worn PA monitor. The existence of a potential interaction between intensity of PA and non-neutral working postures should, therefore, also be further investigated. Such research may provide valuable insight into the association between physical risk factors in the workplace and musculoskeletal health outcomes.</p></sec></body><back><ack id="S9"><title>Acknowledgements</title><p id="P26">This research was supported (in part) by a pilot project grant from the Healthier Workforce Center for Excellence (HWCE) at the University of Iowa. The HWCE is supported by Cooperative Agreement No. U19OH008858 from the Centers for Disease Control and Prevention (CDC) / National Institute for Occupational Safety and Health (NIOSH). The contents are solely the responsibility of the author(s) and do not necessarily represent the official views of the CDC, NIOSH, or the HWCE.</p></ack><ref-list><title>References</title><ref id="R1"><mixed-citation publication-type="journal"><name><surname>Aguilar-Far&#x000ed;as</surname><given-names>N</given-names></name>, <name><surname>Brown</surname><given-names>WJ</given-names></name>, <name><surname>Peeters</surname><given-names>GG</given-names></name>, <year>2014</year>. <article-title>ActiGraph GT3X+ cut-points for identifying sedentary behaviour in older adults in free-living environments</article-title>. <source>Journal of Science and Medicine in Sport</source>
<volume>17</volume>, <fpage>293</fpage>&#x02013;<lpage>299</lpage>.<pub-id pub-id-type="pmid">23932934</pub-id></mixed-citation></ref><ref id="R2"><mixed-citation publication-type="journal"><name><surname>Amasay</surname><given-names>T</given-names></name>, <name><surname>Zodrow</surname><given-names>K</given-names></name>, <name><surname>Kincl</surname><given-names>L</given-names></name>, <name><surname>Hess</surname><given-names>J</given-names></name>, <name><surname>Karduna</surname><given-names>A</given-names></name>, <year>2009</year>. <article-title>Validation of tri-axial accelerometer for the calculation of elevation angles</article-title>. <source>International Journal of Industrial Ergonomics</source>
<volume>39</volume>, <fpage>783</fpage>&#x02013;<lpage>789</lpage>.</mixed-citation></ref><ref id="R3"><mixed-citation publication-type="journal"><name><surname>Arias</surname><given-names>OE</given-names></name>, <name><surname>Caban-Martinez</surname><given-names>AJ</given-names></name>, <name><surname>Umukoro</surname><given-names>PE</given-names></name>, <name><surname>Okechukwu</surname><given-names>CA</given-names></name>, <name><surname>Dennerlein</surname><given-names>JT</given-names></name>, <year>2015</year>. <article-title>Physical activity levels at work and outside of work among Commercial Construction Workers</article-title>. <source>Journal of Occupational and Environmental Medicine</source>
<volume>57</volume>, <fpage>73</fpage>&#x02013;<lpage>78</lpage>.<pub-id pub-id-type="pmid">25563543</pub-id></mixed-citation></ref><ref id="R4"><mixed-citation publication-type="book"><name><surname>Armitage</surname><given-names>P</given-names></name>, <name><surname>Berry</surname><given-names>G</given-names></name>, <name><surname>Matthews</surname><given-names>JN</given-names></name>, <year>2008</year>. <source>Statistical methods in medical research</source>. <publisher-name>John Wiley &#x00026; Sons</publisher-name>.</mixed-citation></ref><ref id="R5"><mixed-citation publication-type="journal"><name><surname>Bassett</surname><given-names>DR</given-names><suffix>Jr</suffix></name>, <name><surname>Ainsworth</surname><given-names>BE</given-names></name>, <name><surname>Swartz</surname><given-names>AM</given-names></name>, <name><surname>Strath</surname><given-names>SJ</given-names></name>, <name><surname>O&#x02019;Brien</surname><given-names>WL</given-names></name>, <name><surname>King</surname><given-names>GA</given-names></name>, <year>2000</year>. <article-title>Validity of four motion sensors in measuring moderate intensity physical activity</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>32</volume>, <fpage>S471</fpage>&#x02013;<lpage>480</lpage>.<pub-id pub-id-type="pmid">10993417</pub-id></mixed-citation></ref><ref id="R6"><mixed-citation publication-type="journal"><name><surname>Berlin</surname><given-names>JE</given-names></name>, <name><surname>Storti</surname><given-names>KL</given-names></name>, <name><surname>Brach</surname><given-names>JS</given-names></name>, <year>2006</year>. <article-title>Using activity monitors to measure physical activity in free-living conditions</article-title>. <source>Physical Therapy</source>
<volume>86</volume>, <fpage>1137</fpage>&#x02013;<lpage>1145</lpage>.<pub-id pub-id-type="pmid">16879047</pub-id></mixed-citation></ref><ref id="R7"><mixed-citation publication-type="journal"><name><surname>Bland</surname><given-names>JM</given-names></name>, <name><surname>Altman</surname><given-names>DG</given-names></name>, <year>2007</year>. <article-title>Agreement between methods of measurement with multiple observations per individual</article-title>. <source>Journal of Biopharmaceutical Statistics</source>
<volume>17</volume>, <fpage>571</fpage>&#x02013;<lpage>582</lpage>.<pub-id pub-id-type="pmid">17613642</pub-id></mixed-citation></ref><ref id="R8"><mixed-citation publication-type="journal"><name><surname>Bravata</surname><given-names>DM</given-names></name>, <name><surname>Smith-Spangler</surname><given-names>C</given-names></name>, <name><surname>Sundaram</surname><given-names>V</given-names></name>, <name><surname>Gienger</surname><given-names>AL</given-names></name>, <name><surname>Lin</surname><given-names>N</given-names></name>, <name><surname>Lewis</surname><given-names>R</given-names></name>, <name><surname>Stave</surname><given-names>CD</given-names></name>, <name><surname>Olkin</surname><given-names>I</given-names></name>, <name><surname>Sirard</surname><given-names>JR</given-names></name>, <year>2007</year>. <article-title>Using pedometers to increase physical activity and improve health: a systematic review</article-title>. <source>Journal of the American Medical Association</source>
<volume>298</volume>, <fpage>2296</fpage>&#x02013;<lpage>2304</lpage>.<pub-id pub-id-type="pmid">18029834</pub-id></mixed-citation></ref><ref id="R9"><mixed-citation publication-type="journal"><name><surname>Brazeau</surname><given-names>A-S</given-names></name>, <name><surname>Beaudoin</surname><given-names>N</given-names></name>, <name><surname>B&#x000e9;lisle</surname><given-names>V</given-names></name>, <name><surname>Messier</surname><given-names>V</given-names></name>, <name><surname>Karelis</surname><given-names>AD</given-names></name>, <name><surname>Rabasa-Lhoret</surname><given-names>R</given-names></name>, <year>2014</year>. <article-title>Validation and reliability of two activity monitor for energy expenditure assessment</article-title>. <source>Journal of Science and Medicine in Sport</source>.</mixed-citation></ref><ref id="R10"><mixed-citation publication-type="journal"><name><surname>Brazendale</surname><given-names>K</given-names></name>, <name><surname>Beets</surname><given-names>MW</given-names></name>, <name><surname>Bornstein</surname><given-names>DB</given-names></name>, <name><surname>Moore</surname><given-names>JB</given-names></name>, <name><surname>Pate</surname><given-names>RR</given-names></name>, <name><surname>Weaver</surname><given-names>RG</given-names></name>, <name><surname>Falck</surname><given-names>RS</given-names></name>, <name><surname>Chandler</surname><given-names>JL</given-names></name>, <name><surname>Andersen</surname><given-names>LB</given-names></name>, <name><surname>Anderssen</surname><given-names>SA</given-names></name>, <year>2015</year>. <article-title>Equating accelerometer estimates among youth: The Rosetta Stone 2</article-title>. <source>Journal of Science and Medicine in Sport</source>.</mixed-citation></ref><ref id="R11"><mixed-citation publication-type="journal"><name><surname>Burdorf</surname><given-names>A</given-names></name>, <name><surname>Van Der Beek</surname><given-names>A</given-names></name>, <year>1999</year>. <article-title>Exposure assessment strategies for work-related risk factors for musculoskeletal disorders</article-title>. <source>Scandinavian Journal of Work, Environment and Health</source>
<volume>25</volume>, <fpage>25</fpage>&#x02013;<lpage>30</lpage>.</mixed-citation></ref><ref id="R12"><mixed-citation publication-type="journal"><name><surname>Chen</surname><given-names>KY</given-names></name>, <name><surname>Bassett</surname><given-names>DR</given-names></name>, <year>2005</year>. <article-title>The technology of accelerometry-based activity monitors: current and future</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>37</volume>, <fpage>S490</fpage>.<pub-id pub-id-type="pmid">16294112</pub-id></mixed-citation></ref><ref id="R13"><mixed-citation publication-type="journal"><name><surname>Cuesta-Vargas</surname><given-names>AI</given-names></name>, <name><surname>Galan-Mercant</surname><given-names>A</given-names></name>, <name><surname>Williams</surname><given-names>JM</given-names></name>, <year>2010</year>. <article-title>The use of inertial sensors system for human motion analysis</article-title>. <source>Physical Therapy Reviews : PTR</source>
<volume>15</volume>, <fpage>462</fpage>&#x02013;<lpage>473</lpage>.<pub-id pub-id-type="pmid">23565045</pub-id></mixed-citation></ref><ref id="R14"><mixed-citation publication-type="journal"><name><surname>da Costa</surname><given-names>BR</given-names></name>, <name><surname>Vieira</surname><given-names>ER</given-names></name>, <year>2010</year>. <article-title>Risk factors for work-related musculoskeletal disorders: A systematic review of recent longitudinal studies</article-title>. <source>American Journal of Industrial Medicine</source>
<volume>53</volume>, <fpage>285</fpage>&#x02013;<lpage>323</lpage>.<pub-id pub-id-type="pmid">19753591</pub-id></mixed-citation></ref><ref id="R15"><mixed-citation publication-type="journal"><name><surname>David</surname><given-names>GC</given-names></name>, <year>2005</year>. <article-title>Ergonomic methods for assessing exposure to risk factors for work-related musculoskeletal disorders</article-title>. <source>Occupational Medicine</source>
<volume>55</volume>, <fpage>190</fpage>&#x02013;<lpage>199</lpage>.<pub-id pub-id-type="pmid">15857898</pub-id></mixed-citation></ref><ref id="R16"><mixed-citation publication-type="journal"><name><surname>Driscoll</surname><given-names>T</given-names></name>, <name><surname>Jacklyn</surname><given-names>G</given-names></name>, <name><surname>Orchard</surname><given-names>J</given-names></name>, <name><surname>Passmore</surname><given-names>E</given-names></name>, <name><surname>Vos</surname><given-names>T</given-names></name>, <name><surname>Freedman</surname><given-names>G</given-names></name>, <name><surname>Lim</surname><given-names>S</given-names></name>, <name><surname>Punnett</surname><given-names>L</given-names></name>, <year>2014</year>. <article-title>The global burden of occupationally related low back pain: estimates from the Global Burden of Disease 2010 study</article-title>. <source>Annals of the Rheumatic Diseases</source>
<volume>73</volume>, <fpage>975</fpage>&#x02013;<lpage>981</lpage>.<pub-id pub-id-type="pmid">24665117</pub-id></mixed-citation></ref><ref id="R17"><mixed-citation publication-type="journal"><name><surname>El-Gohary</surname><given-names>M</given-names></name>, <name><surname>McNames</surname><given-names>J</given-names></name>, <year>2012</year>. <article-title>Shoulder and elbow joint angle tracking with inertial sensors</article-title>. <source>Biomedical Engineering, IEEE Transactions on</source>
<volume>59</volume>, <fpage>2635</fpage>&#x02013;<lpage>2641</lpage>.</mixed-citation></ref><ref id="R18"><mixed-citation publication-type="journal"><name><surname>Freak-Poli</surname><given-names>R</given-names></name>, <name><surname>Wolfe</surname><given-names>R</given-names></name>, <name><surname>Backholer</surname><given-names>K</given-names></name>, <name><surname>De Courten</surname><given-names>M</given-names></name>, <name><surname>Peeters</surname><given-names>A</given-names></name>, <year>2011</year>. <article-title>Impact of a pedometer-based workplace health program on cardiovascular and diabetes risk profile</article-title>. <source>Preventive Medicine</source>
<volume>53</volume>, <fpage>162</fpage>&#x02013;<lpage>171</lpage>.<pub-id pub-id-type="pmid">21762721</pub-id></mixed-citation></ref><ref id="R19"><mixed-citation publication-type="journal"><name><surname>Freedson</surname><given-names>P</given-names></name>, <name><surname>Bowles</surname><given-names>HR</given-names></name>, <name><surname>Troiano</surname><given-names>R</given-names></name>, <name><surname>Haskell</surname><given-names>W</given-names></name>, <year>2012</year>. <article-title>Assessment of physical activity using wearable monitors: recommendations for monitor calibration and use in the field</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>44</volume>, <fpage>S1</fpage>.<pub-id pub-id-type="pmid">22157769</pub-id></mixed-citation></ref><ref id="R20"><mixed-citation publication-type="journal"><name><surname>Freedson</surname><given-names>PS</given-names></name>, <name><surname>Melanson</surname><given-names>E</given-names></name>, <name><surname>Sirard</surname><given-names>J</given-names></name>, <year>1998</year>. <article-title>Calibration of the Computer Science and Applications, Inc. accelerometer</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>30</volume>, <fpage>777</fpage>&#x02013;<lpage>781</lpage>.<pub-id pub-id-type="pmid">9588623</pub-id></mixed-citation></ref><ref id="R21"><mixed-citation publication-type="journal"><name><surname>Godwin</surname><given-names>A</given-names></name>, <name><surname>Agnew</surname><given-names>M</given-names></name>, <name><surname>Stevenson</surname><given-names>J</given-names></name>, <year>2009</year>. <article-title>Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion</article-title>. <source>Journal of Biomechanical Engineering</source>
<volume>131</volume>, <fpage>114501</fpage>.<pub-id pub-id-type="pmid">20353265</pub-id></mixed-citation></ref><ref id="R22"><mixed-citation publication-type="journal"><name><surname>Grydeland</surname><given-names>M</given-names></name>, <name><surname>Hansen</surname><given-names>BH</given-names></name>, <name><surname>Ried-Larsen</surname><given-names>M</given-names></name>, <name><surname>Kolle</surname><given-names>E</given-names></name>, <name><surname>Anderssen</surname><given-names>SA</given-names></name>, <year>2014</year>. <article-title>Comparison of three generations of ActiGraph activity monitors under free-living conditions: do they provide comparable assessments of overall physical activity in 9-year old children?</article-title>
<source>BMC Sports Science, Medicine and Rehabilitation</source>
<volume>6</volume>, <fpage>26</fpage>.</mixed-citation></ref><ref id="R23"><mixed-citation publication-type="journal"><name><surname>Harari</surname><given-names>G</given-names></name>, <name><surname>Green</surname><given-names>MS</given-names></name>, <name><surname>Zelber-Sagi</surname><given-names>S</given-names></name>, <year>2015</year>. <article-title>Combined association of occupational and leisure-time physical activity with all-cause and coronary heart disease mortality among a cohort of men followed-up for 22 years</article-title>. <source>Occupational and Environmental Medicine</source>, <comment>oemed-2014-102613.</comment></mixed-citation></ref><ref id="R24"><mixed-citation publication-type="journal"><name><surname>Haskell</surname><given-names>WL</given-names></name>, <name><surname>Lee</surname><given-names>I-M</given-names></name>, <name><surname>Pate</surname><given-names>RR</given-names></name>, <name><surname>Powell</surname><given-names>KE</given-names></name>, <name><surname>Blair</surname><given-names>SN</given-names></name>, <name><surname>Franklin</surname><given-names>BA</given-names></name>, <name><surname>Macera</surname><given-names>CA</given-names></name>, <name><surname>Heath</surname><given-names>GW</given-names></name>, <name><surname>Thompson</surname><given-names>PD</given-names></name>, <name><surname>Bauman</surname><given-names>A</given-names></name>, <year>2007</year>. <article-title>Physical activity and public health: updated recommendation for adults from the American College of Sports Medicine and the American Heart Association</article-title>. <source>Circulation</source>
<volume>116</volume>, <fpage>1081</fpage>.<pub-id pub-id-type="pmid">17671237</pub-id></mixed-citation></ref><ref id="R25"><mixed-citation publication-type="journal"><name><surname>Hendelman</surname><given-names>D</given-names></name>, <name><surname>Miller</surname><given-names>K</given-names></name>, <name><surname>Baggett</surname><given-names>C</given-names></name>, <name><surname>Debold</surname><given-names>E</given-names></name>, <name><surname>Freedson</surname><given-names>P</given-names></name>, <year>2000</year>. <article-title>Validity of accelerometry for the assessment of moderate intensity physical activity in the field</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>32</volume>, <fpage>S442</fpage>&#x02013;<lpage>449</lpage>.<pub-id pub-id-type="pmid">10993413</pub-id></mixed-citation></ref><ref id="R26"><mixed-citation publication-type="journal"><name><surname>Heneweer</surname><given-names>H</given-names></name>, <name><surname>Staes</surname><given-names>F</given-names></name>, <name><surname>Aufdemkampe</surname><given-names>G</given-names></name>, <name><surname>van Rijn</surname><given-names>M</given-names></name>, <name><surname>Vanhees</surname><given-names>L</given-names></name>, <year>2011</year>. <article-title>Physical activity and low back pain: a systematic review of recent literature</article-title>. <source>European Spine Journal</source>
<volume>20</volume>, <fpage>826</fpage>&#x02013;<lpage>845</lpage>.<pub-id pub-id-type="pmid">21221663</pub-id></mixed-citation></ref><ref id="R27"><mixed-citation publication-type="journal"><name><surname>Heneweer</surname><given-names>H</given-names></name>, <name><surname>Vanhees</surname><given-names>L</given-names></name>, <name><surname>Picavet</surname><given-names>HSJ</given-names></name>, <year>2009</year>. <article-title>Physical activity and low back pain: a U-shaped relation?</article-title>
<source>Pain</source>
<volume>143</volume>, <fpage>21</fpage>&#x02013;<lpage>25</lpage>.<pub-id pub-id-type="pmid">19217208</pub-id></mixed-citation></ref><ref id="R28"><mixed-citation publication-type="journal"><name><surname>Hildebrand</surname><given-names>M</given-names></name>, <name><surname>Van Hees</surname><given-names>VT</given-names></name>, <name><surname>Hansen</surname><given-names>BH</given-names></name>, <name><surname>Ekelund</surname><given-names>U</given-names></name>, <year>2014</year>. <article-title>Age-group comparability of raw accelerometer output from wrist-and hip-worn monitors</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>46</volume>, <fpage>1816</fpage>&#x02013;<lpage>1824</lpage>.<pub-id pub-id-type="pmid">24887173</pub-id></mixed-citation></ref><ref id="R29"><mixed-citation publication-type="journal"><name><surname>Hildebrandt</surname><given-names>V</given-names></name>, <name><surname>Bongers</surname><given-names>P</given-names></name>, <name><surname>Dul</surname><given-names>J</given-names></name>, <name><surname>Van Dijk</surname><given-names>F</given-names></name>, <name><surname>Kemper</surname><given-names>H</given-names></name>, <year>2000</year>. <article-title>The relationship between leisure time, physical activities and musculoskeletal symptoms and disability in worker populations</article-title>. <source>International Archives of Occupational and Environmental Health</source>
<volume>73</volume>, <fpage>507</fpage>&#x02013;<lpage>518</lpage>.<pub-id pub-id-type="pmid">11100945</pub-id></mixed-citation></ref><ref id="R30"><mixed-citation publication-type="journal"><name><surname>Hirschhorn</surname><given-names>ADL</given-names></name>, <name><surname>John</surname><given-names>W</given-names></name>; <name><surname>Breckenridge</surname><given-names>John D.</given-names></name>, <year>2015</year>. <article-title>Can a physical activity monitor provide a valid measure of arm elevation angle? A study to assess agreement between the SenseWear Mini Armband and the universal goniometer</article-title>. <source>BMC Musculoskeletal Disorders</source>
<volume>16</volume>.</mixed-citation></ref><ref id="R31"><mixed-citation publication-type="journal"><name><surname>Holtermann</surname><given-names>A</given-names></name>, <year>2015</year>. <article-title>Occupational and leisure-time physical activity and coronary heart disease</article-title>. <source>Occupational and Environmental Medicine</source>, <comment>oemed-2015-102933.</comment></mixed-citation></ref><ref id="R32"><mixed-citation publication-type="journal"><name><surname>Holtermann</surname><given-names>A</given-names></name>, <name><surname>Burr</surname><given-names>H</given-names></name>, <name><surname>Hansen</surname><given-names>JV</given-names></name>, <name><surname>Krause</surname><given-names>N</given-names></name>, <name><surname>S&#x000f8;gaard</surname><given-names>K</given-names></name>, <name><surname>Mortensen</surname><given-names>OS</given-names></name>, <year>2012a</year>. <article-title>Occupational physical activity and mortality among Danish workers</article-title>. <source>International Archives of Occupational and Environmental Health</source>
<volume>85</volume>, <fpage>305</fpage>&#x02013;<lpage>310</lpage>.<pub-id pub-id-type="pmid">21695437</pub-id></mixed-citation></ref><ref id="R33"><mixed-citation publication-type="journal"><name><surname>Holtermann</surname><given-names>A</given-names></name>, <name><surname>Hansen</surname><given-names>J</given-names></name>, <name><surname>Burr</surname><given-names>H</given-names></name>, <name><surname>S&#x000f8;gaard</surname><given-names>K</given-names></name>, <name><surname>Sj&#x000f8;gaard</surname><given-names>G</given-names></name>, <year>2012b</year>. <article-title>The health paradox of occupational and leisure-time physical activity</article-title>. <source>British Journal of Sports Medicine</source>
<volume>46</volume>, <fpage>291</fpage>&#x02013;<lpage>295</lpage>.<pub-id pub-id-type="pmid">21459873</pub-id></mixed-citation></ref><ref id="R34"><mixed-citation publication-type="journal"><name><surname>Holtermann</surname><given-names>A</given-names></name>, <name><surname>Mortensen</surname><given-names>OS</given-names></name>, <name><surname>Burr</surname><given-names>H</given-names></name>, <name><surname>S&#x000f8;gaard</surname><given-names>K</given-names></name>, <name><surname>Gyntelberg</surname><given-names>F</given-names></name>, <name><surname>Suadicani</surname><given-names>P</given-names></name>, <year>2010</year>. <article-title>Physical work demands, hypertension status, and risk of ischemie heart disease and all-cause mortality in the Copenhagen Male Study</article-title>. <source>Scandinavian Journal of Work, Environment and Health</source>, <fpage>466</fpage>&#x02013;<lpage>472</lpage>.</mixed-citation></ref><ref id="R35"><mixed-citation publication-type="journal"><name><surname>Hoy</surname><given-names>D</given-names></name>, <name><surname>Bain</surname><given-names>C</given-names></name>, <name><surname>Williams</surname><given-names>G</given-names></name>, <name><surname>March</surname><given-names>L</given-names></name>, <name><surname>Brooks</surname><given-names>P</given-names></name>, <name><surname>Blyth</surname><given-names>F</given-names></name>, <name><surname>Woolf</surname><given-names>A</given-names></name>, <name><surname>Vos</surname><given-names>T</given-names></name>, <name><surname>Buchbinder</surname><given-names>R</given-names></name>, <year>2012</year>. <article-title>A systematic review of the global prevalence of low back pain</article-title>. <source>Arthritis and Rheumatism</source>
<volume>64</volume>, <fpage>2028</fpage>&#x02013;<lpage>2037</lpage>.<pub-id pub-id-type="pmid">22231424</pub-id></mixed-citation></ref><ref id="R36"><mixed-citation publication-type="journal"><name><surname>Hoy</surname><given-names>D</given-names></name>, <name><surname>March</surname><given-names>L</given-names></name>, <name><surname>Brooks</surname><given-names>P</given-names></name>, <name><surname>Blyth</surname><given-names>F</given-names></name>, <name><surname>Woolf</surname><given-names>A</given-names></name>, <name><surname>Bain</surname><given-names>C</given-names></name>, <name><surname>Williams</surname><given-names>G</given-names></name>, <name><surname>Smith</surname><given-names>E</given-names></name>, <name><surname>Vos</surname><given-names>T</given-names></name>, <name><surname>Barendregt</surname><given-names>J</given-names></name>, <year>2014a</year>. <article-title>The global burden of low back pain: estimates from the Global Burden of Disease 2010 study</article-title>. <source>Annals of the Rheumatic Diseases</source>
<volume>73</volume>, <fpage>968</fpage>&#x02013;<lpage>974</lpage>.<pub-id pub-id-type="pmid">24665116</pub-id></mixed-citation></ref><ref id="R37"><mixed-citation publication-type="journal"><name><surname>Hoy</surname><given-names>D</given-names></name>, <name><surname>March</surname><given-names>L</given-names></name>, <name><surname>Woolf</surname><given-names>A</given-names></name>, <name><surname>Blyth</surname><given-names>F</given-names></name>, <name><surname>Brooks</surname><given-names>P</given-names></name>, <name><surname>Smith</surname><given-names>E</given-names></name>, <name><surname>Vos</surname><given-names>T</given-names></name>, <name><surname>Barendregt</surname><given-names>J</given-names></name>, <name><surname>Blore</surname><given-names>J</given-names></name>, <name><surname>Murray</surname><given-names>C</given-names></name>, <name><surname>Burstein</surname><given-names>R</given-names></name>, <name><surname>Buchbinder</surname><given-names>R</given-names></name>, <year>2014b</year>. <article-title>The global burden of neck pain: estimates from the Global Burden of Disease 2010 study</article-title>. <source>Annals of Rheumatic Diseases</source>
<volume>73</volume>, <fpage>1309</fpage>&#x02013;<lpage>1315</lpage>.</mixed-citation></ref><ref id="R38"><mixed-citation publication-type="journal"><name><surname>Jarrett</surname><given-names>H</given-names></name>, <name><surname>Fitzgerald</surname><given-names>L</given-names></name>, <name><surname>Routen</surname><given-names>AC</given-names></name>, <year>2014</year>. <article-title>Inter-instrument reliability of the actigraph GT3X+ ambulatory activity monitor during free-living conditions in adults</article-title>. <source>Journal of Physical Activity and Health</source>.</mixed-citation></ref><ref id="R39"><mixed-citation publication-type="journal"><name><surname>John</surname><given-names>D</given-names></name>, <name><surname>Freedson</surname><given-names>P</given-names></name>, <year>2012</year>. <article-title>ActiGraph and Actical physical activity monitors: a peek under the hood</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>44</volume>, <fpage>S86</fpage>.<pub-id pub-id-type="pmid">22157779</pub-id></mixed-citation></ref><ref id="R40"><mixed-citation publication-type="journal"><name><surname>John</surname><given-names>D</given-names></name>, <name><surname>Sasaki</surname><given-names>J</given-names></name>, <name><surname>Staudenmayer</surname><given-names>J</given-names></name>, <name><surname>Mavilia</surname><given-names>M</given-names></name>, <name><surname>Freedson</surname><given-names>PS</given-names></name>, <year>2013</year>. <article-title>Comparison of raw acceleration from the GENEA and ActiGraph<sup>&#x02122;</sup> GT3X+ activity monitors</article-title>. <source>Sensors</source>
<volume>13</volume>, <fpage>14754</fpage>&#x02013;<lpage>14763</lpage>.<pub-id pub-id-type="pmid">24177727</pub-id></mixed-citation></ref><ref id="R41"><mixed-citation publication-type="journal"><name><surname>John</surname><given-names>D</given-names></name>, <name><surname>Tyo</surname><given-names>B</given-names></name>, <name><surname>Bassett</surname><given-names>DR</given-names></name>, <year>2010</year>. <article-title>Comparison of four ActiGraph accelerometers during walking and running</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>42</volume>, <fpage>368</fpage>.<pub-id pub-id-type="pmid">19927022</pub-id></mixed-citation></ref><ref id="R42"><mixed-citation publication-type="journal"><name><surname>Kelly</surname><given-names>LA</given-names></name>, <name><surname>McMillan</surname><given-names>DG</given-names></name>, <name><surname>Anderson</surname><given-names>A</given-names></name>, <name><surname>Fippinger</surname><given-names>M</given-names></name>, <name><surname>Fillerup</surname><given-names>G</given-names></name>, <name><surname>Rider</surname><given-names>J</given-names></name>, <year>2013</year>. <article-title>Validity of actigraphs uniaxial and triaxial accelerometers for assessment of physical activity in adults in laboratory conditions</article-title>. <source>BMC Medical Physics</source>
<volume>13</volume>, <fpage>5</fpage>.<pub-id pub-id-type="pmid">24279826</pub-id></mixed-citation></ref><ref id="R43"><mixed-citation publication-type="journal"><name><surname>Kim</surname><given-names>S</given-names></name>, <name><surname>Nussbaum</surname><given-names>MA</given-names></name>, <year>2013</year>. <article-title>Performance evaluation of a wearable inertial motion capture system for capturing physical exposures during manual material handling tasks</article-title>. <source>Ergonomics</source>
<volume>56</volume>, <fpage>314</fpage>&#x02013;<lpage>326</lpage>.<pub-id pub-id-type="pmid">23231730</pub-id></mixed-citation></ref><ref id="R44"><mixed-citation publication-type="journal"><name><surname>Korsh&#x000f8;j</surname><given-names>M</given-names></name>, <name><surname>Skotte</surname><given-names>JH</given-names></name>, <name><surname>Christiansen</surname><given-names>CS</given-names></name>, <name><surname>Mortensen</surname><given-names>P</given-names></name>, <name><surname>Kristiansen</surname><given-names>J</given-names></name>, <name><surname>Hanisch</surname><given-names>C</given-names></name>, <name><surname>Ingebrigtsen</surname><given-names>J</given-names></name>, <name><surname>Holtermann</surname><given-names>A</given-names></name>, <year>2014</year>. <article-title>Validity of the Acti4 software using ActiGraph GT3X+ accelerometer for recording of arm and upper body inclination in simulated work tasks</article-title>. <source>Ergonomics</source>
<volume>57</volume>, <fpage>247</fpage>&#x02013;<lpage>253</lpage>.<pub-id pub-id-type="pmid">24392673</pub-id></mixed-citation></ref><ref id="R45"><mixed-citation publication-type="journal"><name><surname>Kowalski</surname><given-names>K</given-names></name>, <name><surname>Rhodes</surname><given-names>R</given-names></name>, <name><surname>Naylor</surname><given-names>P-J</given-names></name>, <name><surname>Tuokko</surname><given-names>H</given-names></name>, <name><surname>MacDonald</surname><given-names>S</given-names></name>, <year>2012</year>. <article-title>Direct and indirect measurement of physical activity in older adults: a systematic review of the literature</article-title>. <source>International Journal of Behavioral Nutrition and Physical Activity</source>
<volume>9</volume>, <fpage>148</fpage>.<pub-id pub-id-type="pmid">23245612</pub-id></mixed-citation></ref><ref id="R46"><mixed-citation publication-type="journal"><name><surname>Li</surname><given-names>G</given-names></name>, <name><surname>Buckle</surname><given-names>P</given-names></name>, <year>1999</year>. <article-title>Current techniques for assessing physical exposure to work-related musculoskeletal risks, with emphasis on posture-based methods</article-title>. <source>Ergonomics</source>
<volume>42</volume>, <fpage>674</fpage>&#x02013;<lpage>695</lpage>.<pub-id pub-id-type="pmid">10327891</pub-id></mixed-citation></ref><ref id="R47"><mixed-citation publication-type="journal"><name><surname>Ludbrook</surname><given-names>J</given-names></name>, <year>2010</year>. <article-title>Confidence in Altman&#x02013;Bland plots: a critical review of the method of differences</article-title>. <source>Clinical and Experimental Pharmacology and Physiology</source>
<volume>37</volume>, <fpage>143</fpage>&#x02013;<lpage>149</lpage>.<pub-id pub-id-type="pmid">19719745</pub-id></mixed-citation></ref><ref id="R48"><mixed-citation publication-type="journal"><name><surname>Luinge</surname><given-names>HJ</given-names></name>, <name><surname>Veltink</surname><given-names>PH</given-names></name>, <year>2005</year>. <article-title>Measuring orientation of human body segments using miniature gyroscopes and accelerometers</article-title>. <source>Medical and Biological Engineering and Computing</source>
<volume>43</volume>, <fpage>273</fpage>&#x02013;<lpage>282</lpage>.<pub-id pub-id-type="pmid">15865139</pub-id></mixed-citation></ref><ref id="R49"><mixed-citation publication-type="journal"><name><surname>Malik</surname><given-names>SH</given-names></name>, <name><surname>Blake</surname><given-names>H</given-names></name>, <name><surname>Suggs</surname><given-names>LS</given-names></name>, <year>2014</year>. <article-title>A systematic review of workplace health promotion interventions for increasing physical activity</article-title>. <source>British Journal of Health Psychology</source>
<volume>19</volume>, <fpage>149</fpage>&#x02013;<lpage>180</lpage>.<pub-id pub-id-type="pmid">23827053</pub-id></mixed-citation></ref><ref id="R50"><mixed-citation publication-type="journal"><name><surname>Matthews</surname><given-names>CE</given-names></name>, <year>2005</year>. <article-title>Calibration of accelerometer output for adults</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>37</volume>, <fpage>S512</fpage>.<pub-id pub-id-type="pmid">16294114</pub-id></mixed-citation></ref><ref id="R51"><mixed-citation publication-type="journal"><name><surname>Matthews</surname><given-names>CE</given-names></name>, <name><surname>Hagstr&#x000f6;mer</surname><given-names>M</given-names></name>, <name><surname>Pober</surname><given-names>DM</given-names></name>, <name><surname>Bowles</surname><given-names>HR</given-names></name>, <year>2012</year>. <article-title>Best practices for using physical activity monitors in population-based research</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>44</volume>, <fpage>S68</fpage>.<pub-id pub-id-type="pmid">22157777</pub-id></mixed-citation></ref><ref id="R52"><mixed-citation publication-type="journal"><name><surname>Miranda</surname><given-names>H</given-names></name>, <name><surname>Viikari-Juntura</surname><given-names>E</given-names></name>, <name><surname>Martikainen</surname><given-names>R</given-names></name>, <name><surname>Takala</surname><given-names>E</given-names></name>, <name><surname>Riihim&#x000e4;ki</surname><given-names>H</given-names></name>, <year>2001</year>. <article-title>A prospective study of work related factors and physical exercise as predictors of shoulder pain</article-title>. <source>Occupational and Environmental Medicine</source>
<volume>58</volume>, <fpage>528</fpage>&#x02013;<lpage>534</lpage>.<pub-id pub-id-type="pmid">11452048</pub-id></mixed-citation></ref><ref id="R53"><mixed-citation publication-type="journal"><name><surname>Murray</surname><given-names>CJ</given-names></name>, <name><surname>Vos</surname><given-names>T</given-names></name>, <name><surname>Lozano</surname><given-names>R</given-names></name>, <name><surname>Naghavi</surname><given-names>M</given-names></name>, <name><surname>Flaxman</surname><given-names>AD</given-names></name>, <name><surname>Michaud</surname><given-names>C</given-names></name>, <name><surname>Ezzati</surname><given-names>M</given-names></name>, <name><surname>Shibuya</surname><given-names>K</given-names></name>, <name><surname>Salomon</surname><given-names>JA</given-names></name>, <name><surname>Abdalla</surname><given-names>S</given-names></name>, <year>2013</year>. <article-title>Disability-adjusted life years (DALYs) for 291 diseases and injuries in 21 regions, 1990&#x02013;2010: a systematic analysis for the Global Burden of Disease Study 2010</article-title>. <source>The Lancet</source>
<volume>380</volume>, <fpage>2197</fpage>&#x02013;<lpage>2223</lpage>.</mixed-citation></ref><ref id="R54"><mixed-citation publication-type="journal"><name><surname>Ohlsson</surname><given-names>K</given-names></name>, <name><surname>Attewell</surname><given-names>RG</given-names></name>, <name><surname>Johnsson</surname><given-names>B</given-names></name>, <name><surname>Ahml</surname><given-names>A</given-names></name>, <name><surname>Skerfving</surname><given-names>S</given-names></name>, <year>1994</year>. <article-title>An assessment of neck and upper extremity disorders by questionnaire and clinical examination</article-title>. <source>Ergonomics</source>
<volume>37</volume>, <fpage>891</fpage>&#x02013;<lpage>897</lpage>.<pub-id pub-id-type="pmid">8206057</pub-id></mixed-citation></ref><ref id="R55"><mixed-citation publication-type="journal"><name><surname>Pal</surname><given-names>S</given-names></name>, <name><surname>Cheng</surname><given-names>C</given-names></name>, <name><surname>Egger</surname><given-names>G</given-names></name>, <name><surname>Binns</surname><given-names>C</given-names></name>, <name><surname>Donovan</surname><given-names>R</given-names></name>, <year>2009</year>. <article-title>Using pedometers to increase physical activity in overweight and obese women: a pilot study</article-title>. <source>BMC Public Health</source>
<volume>9</volume>, <fpage>309</fpage>.<pub-id pub-id-type="pmid">19703317</pub-id></mixed-citation></ref><ref id="R56"><mixed-citation publication-type="journal"><name><surname>Prince</surname><given-names>SA</given-names></name>, <name><surname>Adamo</surname><given-names>KB</given-names></name>, <name><surname>Hamel</surname><given-names>ME</given-names></name>, <name><surname>Hardt</surname><given-names>J</given-names></name>, <name><surname>Gorber</surname><given-names>SC</given-names></name>, <name><surname>Tremblay</surname><given-names>M</given-names></name>, <year>2008</year>. <article-title>A comparison of direct versus self-report measures for assessing physical activity in adults: a systematic review</article-title>. <source>International Journal of Behavioral Nutrition and Physical Activity</source>
<volume>5</volume>, <fpage>56</fpage>.<pub-id pub-id-type="pmid">18990237</pub-id></mixed-citation></ref><ref id="R57"><mixed-citation publication-type="journal"><name><surname>Roetenberg</surname><given-names>D</given-names></name>, <name><surname>Slycke</surname><given-names>PJ</given-names></name>, <name><surname>Veltink</surname><given-names>PH</given-names></name>, <year>2007</year>. <article-title>Ambulatory position and orientation tracking fusing magnetic and inertial sensing</article-title>. <source>Biomedical Engineering, IEEE Transactions on</source>
<volume>54</volume>, <fpage>883</fpage>&#x02013;<lpage>890</lpage>.</mixed-citation></ref><ref id="R58"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Oyama</surname><given-names>S</given-names></name>, <name><surname>Douphrate</surname><given-names>DI</given-names></name>, <year>2015a</year>. <article-title>Accuracy and repeatability of an inertial measurement unit system for field-based occupational studies</article-title>. <source>Ergonomics</source>.</mixed-citation></ref><ref id="R59"><mixed-citation publication-type="journal"><name><surname>Schall</surname><given-names>MC</given-names><suffix>Jr</suffix></name>, <name><surname>Fethke</surname><given-names>NB</given-names></name>, <name><surname>Chen</surname><given-names>H</given-names></name>, <name><surname>Gerr</surname><given-names>F</given-names></name>, <year>2015b</year>. <article-title>A comparison of instrumentation methods to estimate thoracolumbar motion in field-based occupational studies</article-title>. <source>Applied Ergonomics</source>
<volume>48</volume>, <fpage>224</fpage>&#x02013;<lpage>231</lpage>.<pub-id pub-id-type="pmid">25683549</pub-id></mixed-citation></ref><ref id="R60"><mixed-citation publication-type="journal"><name><surname>Sesso</surname><given-names>HD</given-names></name>, <name><surname>Paffenbarger</surname><given-names>RS</given-names></name>, <name><surname>Lee</surname><given-names>I-M</given-names></name>, <year>2000</year>. <article-title>Physical activity and coronary heart disease in men the Harvard Alumni Health Study</article-title>. <source>Circulation</source>
<volume>102</volume>, <fpage>975</fpage>&#x02013;<lpage>980</lpage>.<pub-id pub-id-type="pmid">10961960</pub-id></mixed-citation></ref><ref id="R61"><mixed-citation publication-type="journal"><name><surname>Silverstein</surname><given-names>BA</given-names></name>, <name><surname>Bao</surname><given-names>SS</given-names></name>, <name><surname>Fan</surname><given-names>ZJ</given-names></name>, <name><surname>Howard</surname><given-names>N</given-names></name>, <name><surname>Smith</surname><given-names>C</given-names></name>, <name><surname>Spielholz</surname><given-names>P</given-names></name>, <name><surname>Bonauto</surname><given-names>D</given-names></name>, <name><surname>Viikari-Juntura</surname><given-names>E</given-names></name>, <year>2008</year>. <article-title>Rotator cuff syndrome: personal, work-related psychosocial and physical load factors</article-title>. <source>Journal of Occupational and Environmental Medicine</source>
<volume>50</volume>, <fpage>1062</fpage>&#x02013;<lpage>1076</lpage>.<pub-id pub-id-type="pmid">18784555</pub-id></mixed-citation></ref><ref id="R62"><mixed-citation publication-type="journal"><name><surname>Silverstein</surname><given-names>BA</given-names></name>, <name><surname>Viikari-Juntura</surname><given-names>E</given-names></name>, <name><surname>Fan</surname><given-names>ZJ</given-names></name>, <name><surname>Bonauto</surname><given-names>DK</given-names></name>, <name><surname>Bao</surname><given-names>S</given-names></name>, <name><surname>Smith</surname><given-names>C</given-names></name>, <year>2006</year>. <article-title>Natural course of nontraumatic rotator cuff tendinitis and shoulder symptoms in a working population</article-title>. <source>Scandinavian Journal of Work, Environment and Health</source>, <fpage>99</fpage>&#x02013;<lpage>108</lpage>.</mixed-citation></ref><ref id="R63"><mixed-citation publication-type="journal"><name><surname>Sitthipornvorakul</surname><given-names>E</given-names></name>, <name><surname>Janwantanakul</surname><given-names>P</given-names></name>, <name><surname>Purepong</surname><given-names>N</given-names></name>, <name><surname>Pensri</surname><given-names>P</given-names></name>, <name><surname>van der Beek</surname><given-names>AJ</given-names></name>, <year>2011</year>. <article-title>The association between physical activity and neck and low back pain: a systematic review</article-title>. <source>European Spine Journal</source>
<volume>20</volume>, <fpage>677</fpage>&#x02013;<lpage>689</lpage>.<pub-id pub-id-type="pmid">21113635</pub-id></mixed-citation></ref><ref id="R64"><mixed-citation publication-type="journal"><name><surname>Svendsen</surname><given-names>SW</given-names></name>, <name><surname>Bonde</surname><given-names>JP</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <name><surname>Stengaard-Pedersen</surname><given-names>K</given-names></name>, <name><surname>Frich</surname><given-names>LH</given-names></name>, <year>2004a</year>. <article-title>Work related shoulder disorders: quantitative exposure-response relations with reference to arm posture</article-title>. <source>Occupational and Environmental Medicine</source>
<volume>61</volume>, <fpage>844</fpage>&#x02013;<lpage>853</lpage>.<pub-id pub-id-type="pmid">15377771</pub-id></mixed-citation></ref><ref id="R65"><mixed-citation publication-type="journal"><name><surname>Svendsen</surname><given-names>SW</given-names></name>, <name><surname>Gelineck</surname><given-names>J</given-names></name>, <name><surname>Mathiassen</surname><given-names>SE</given-names></name>, <name><surname>Bonde</surname><given-names>JP</given-names></name>, <name><surname>Frich</surname><given-names>LH</given-names></name>, <name><surname>Stengaard-Pedersen</surname><given-names>K</given-names></name>, <name><surname>Egund</surname><given-names>N</given-names></name>, <year>2004b</year>. <article-title>Work above shoulder level and degenerative alterations of the rotator cuff tendons: a magnetic resonance imaging study</article-title>. <source>Arthritis and Rheumatism</source>
<volume>50</volume>, <fpage>3314</fpage>&#x02013;<lpage>3322</lpage>.<pub-id pub-id-type="pmid">15476229</pub-id></mixed-citation></ref><ref id="R66"><mixed-citation publication-type="journal"><name><surname>Taraldsen</surname><given-names>K</given-names></name>, <name><surname>Chastin</surname><given-names>SF</given-names></name>, <name><surname>Riphagen</surname><given-names>II</given-names></name>, <name><surname>Vereijken</surname><given-names>B</given-names></name>, <name><surname>Helbostad</surname><given-names>JL</given-names></name>, <year>2012</year>. <article-title>Physical activity monitoring by use of accelerometer-based body-worn sensors in older adults: a systematic literature review of current knowledge and applications</article-title>. <source>Maturitas</source>
<volume>71</volume>, <fpage>13</fpage>&#x02013;<lpage>19</lpage>.<pub-id pub-id-type="pmid">22134002</pub-id></mixed-citation></ref><ref id="R67"><mixed-citation publication-type="journal"><name><surname>Teschke</surname><given-names>K</given-names></name>, <name><surname>Trask</surname><given-names>C</given-names></name>, <name><surname>Johnson</surname><given-names>P</given-names></name>, <name><surname>Chow</surname><given-names>Y</given-names></name>, <name><surname>Village</surname><given-names>J</given-names></name>, <name><surname>Koehoorn</surname><given-names>M</given-names></name>, <year>2009</year>. <article-title>Measuring posture for epidemiology: comparing inclinometry, observations and self-reports</article-title>. <source>Ergonomics</source>
<volume>52</volume>, <fpage>1067</fpage>&#x02013;<lpage>1078</lpage>.<pub-id pub-id-type="pmid">19787510</pub-id></mixed-citation></ref><ref id="R68"><mixed-citation publication-type="journal"><name><surname>Thiese</surname><given-names>M</given-names></name>, <year>2014</year>. <article-title>Important differences in accelerometer cut points for quantifying physical activity in a nested occupational cohort</article-title>. <source>Journal of Exercise, Sports, and Orthopedics</source>
<volume>1</volume>, <fpage>12</fpage>.</mixed-citation></ref><ref id="R69"><mixed-citation publication-type="journal"><name><surname>Troiano</surname><given-names>RP</given-names></name>, <name><surname>Berrigan</surname><given-names>D</given-names></name>, <name><surname>Dodd</surname><given-names>KW</given-names></name>, <name><surname>M&#x000e2;sse</surname><given-names>LC</given-names></name>, <name><surname>Tilert</surname><given-names>T</given-names></name>, <name><surname>McDowell</surname><given-names>M</given-names></name>, <year>2008</year>. <article-title>Physical activity in the United States measured by accelerometer</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>40</volume>, <fpage>181</fpage>.<pub-id pub-id-type="pmid">18091006</pub-id></mixed-citation></ref><ref id="R70"><mixed-citation publication-type="journal"><name><surname>Trost</surname><given-names>SG</given-names></name>, <name><surname>Pate</surname><given-names>RR</given-names></name>, <name><surname>Freedson</surname><given-names>PS</given-names></name>, <name><surname>Sallis</surname><given-names>JF</given-names></name>, <name><surname>Taylor</surname><given-names>WC</given-names></name>, <year>2000</year>. <article-title>Using objective physical activity measures with youth: how many days of monitoring are needed?</article-title>
<source>Medicine and Science in Sports and Exercise</source>
<volume>32</volume>, <fpage>426</fpage>&#x02013;<lpage>431</lpage>.<pub-id pub-id-type="pmid">10694127</pub-id></mixed-citation></ref><ref id="R71"><mixed-citation publication-type="journal"><name><surname>Umukoro</surname><given-names>PE</given-names></name>, <name><surname>Arias</surname><given-names>OE</given-names></name>, <name><surname>Stoffel</surname><given-names>SD</given-names></name>, <name><surname>Hopcia</surname><given-names>K</given-names></name>, <name><surname>Sorensen</surname><given-names>G</given-names></name>, <name><surname>Dennerlein</surname><given-names>JT</given-names></name>, <year>2013</year>. <article-title>Physical Activity at Work Contributes Little to Patient Care Workers&#x02019; Weekly Totals</article-title>. <source>Journal of Occupational and Environmental Medicine</source>
<volume>55</volume>, <fpage>S63</fpage>&#x02013;<lpage>S68</lpage>.<pub-id pub-id-type="pmid">24284756</pub-id></mixed-citation></ref><ref id="R72"><mixed-citation publication-type="journal"><name><surname>van der Windt</surname><given-names>DA</given-names></name>, <name><surname>Thomas</surname><given-names>E</given-names></name>, <name><surname>Pope</surname><given-names>DP</given-names></name>, <name><surname>de Winter</surname><given-names>AF</given-names></name>, <name><surname>Macfarlane</surname><given-names>GJ</given-names></name>, <name><surname>Bouter</surname><given-names>LM</given-names></name>, <name><surname>Silman</surname><given-names>AJ</given-names></name>, <year>2000</year>. <article-title>Occupational risk factors for shoulder pain: a systematic review</article-title>. <source>Occupational and Environmental Medicine</source>
<volume>57</volume>, <fpage>433</fpage>&#x02013;<lpage>442</lpage>.<pub-id pub-id-type="pmid">10854494</pub-id></mixed-citation></ref><ref id="R73"><mixed-citation publication-type="journal"><name><surname>van Hees</surname><given-names>VT</given-names></name>, <name><surname>Gorzelniak</surname><given-names>L</given-names></name>, <name><surname>Leon</surname><given-names>ECD</given-names></name>, <name><surname>Eder</surname><given-names>M</given-names></name>, <name><surname>Pias</surname><given-names>M</given-names></name>, <name><surname>Taherian</surname><given-names>S</given-names></name>, <name><surname>Ekelund</surname><given-names>U</given-names></name>, <name><surname>Renstr&#x000f6;m</surname><given-names>F</given-names></name>, <name><surname>Franks</surname><given-names>PW</given-names></name>, <name><surname>Horsch</surname><given-names>A</given-names></name>, <year>2013</year>. <article-title>Separating movement and gravity components in an acceleration signal and implications for the assessment of human daily physical activity</article-title>. <source>PLoS One</source>
<volume>8</volume>, <fpage>e61691</fpage>.<pub-id pub-id-type="pmid">23626718</pub-id></mixed-citation></ref><ref id="R74"><mixed-citation publication-type="journal"><name><surname>Van Remoortel</surname><given-names>H</given-names></name>, <name><surname>Giavedoni</surname><given-names>S</given-names></name>, <name><surname>Raste</surname><given-names>Y</given-names></name>, <name><surname>Burtin</surname><given-names>C</given-names></name>, <name><surname>Louvaris</surname><given-names>Z</given-names></name>, <name><surname>Gimeno-Santos</surname><given-names>E</given-names></name>, <name><surname>Langer</surname><given-names>D</given-names></name>, <name><surname>Glendenning</surname><given-names>A</given-names></name>, <name><surname>Hopkinson</surname><given-names>NS</given-names></name>, <name><surname>Vogiatzis</surname><given-names>I</given-names></name>, <year>2012</year>. <article-title>Validity of activity monitors in health and chronic disease: a systematic review</article-title>. <source>International Journal of Behavioral Nutrition and Physical Activity</source>
<volume>9</volume>, <fpage>84</fpage>.<pub-id pub-id-type="pmid">22776399</pub-id></mixed-citation></ref><ref id="R75"><mixed-citation publication-type="journal"><name><surname>van Rijn</surname><given-names>RM</given-names></name>, <name><surname>Huisstede</surname><given-names>BMA</given-names></name>, <name><surname>Koes</surname><given-names>BW</given-names></name>, <name><surname>Burdorf</surname><given-names>A</given-names></name>, <year>2010</year>. <article-title>Associations between work-related factors and specific disorders of the shoulder &#x02013; a systematic review of the literature</article-title>. <source>Scandinavian Journal of Work</source>, Environment and Health <volume>36</volume>, <fpage>189</fpage>&#x02013;<lpage>201</lpage>.</mixed-citation></ref><ref id="R76"><mixed-citation publication-type="journal"><name><surname>van Sluijs</surname><given-names>EM</given-names></name>, <name><surname>van Poppel</surname><given-names>MN</given-names></name>, <name><surname>Twisk</surname><given-names>JW</given-names></name>, <name><surname>van Mechelen</surname><given-names>W</given-names></name>, <year>2006</year>. <article-title>Physical activity measurements affected participants&#x02019; behavior in a randomized controlled trial</article-title>. <source>Journal of Clinical Epidemiology</source>
<volume>59</volume>, <fpage>404</fpage>&#x02013;<lpage>411</lpage>.<pub-id pub-id-type="pmid">16549263</pub-id></mixed-citation></ref><ref id="R77"><mixed-citation publication-type="journal"><name><surname>Vanhelst</surname><given-names>J</given-names></name>, <name><surname>Theunynck</surname><given-names>D</given-names></name>, <name><surname>Gottrand</surname><given-names>F</given-names></name>, <name><surname>B&#x000e9;ghin</surname><given-names>L</given-names></name>, <year>2010</year>. <article-title>Reliability of the RT3 accelerometer for measurement of physical activity in adolescents</article-title>. <source>Journal of Sports Sciences</source>
<volume>28</volume>, <fpage>375</fpage>&#x02013;<lpage>379</lpage>.<pub-id pub-id-type="pmid">20175016</pub-id></mixed-citation></ref><ref id="R78"><mixed-citation publication-type="journal"><name><surname>Vieira</surname><given-names>ER</given-names></name>, <name><surname>Kumar</surname><given-names>S</given-names></name>, <year>2004</year>. <article-title>Working postures: a literature review</article-title>. <source>Journal of Occupational Rehabilitation</source>
<volume>14</volume>, <fpage>143</fpage>&#x02013;<lpage>159</lpage>.<pub-id pub-id-type="pmid">15074366</pub-id></mixed-citation></ref><ref id="R79"><mixed-citation publication-type="journal"><name><surname>Warburton</surname><given-names>DE</given-names></name>, <name><surname>Nicol</surname><given-names>CW</given-names></name>, <name><surname>Bredin</surname><given-names>SS</given-names></name>, <year>2006</year>. <article-title>Health benefits of physical activity: the evidence</article-title>. <source>Canadian Medical Association Journal</source>
<volume>174</volume>, <fpage>801</fpage>&#x02013;<lpage>809</lpage>.<pub-id pub-id-type="pmid">16534088</pub-id></mixed-citation></ref><ref id="R80"><mixed-citation publication-type="journal"><name><surname>Welk</surname><given-names>GJ</given-names></name>, <name><surname>McClain</surname><given-names>J</given-names></name>, <name><surname>Ainsworth</surname><given-names>BE</given-names></name>, <year>2012</year>. <article-title>Protocols for evaluating equivalency of accelerometry-based activity monitors</article-title>. <source>Medicine and Science in Sports and Exercise</source>
<volume>44</volume>, <fpage>S39</fpage>&#x02013;<lpage>49</lpage>.<pub-id pub-id-type="pmid">22157773</pub-id></mixed-citation></ref><ref id="R81"><mixed-citation publication-type="journal"><name><surname>Yang</surname><given-names>CC</given-names></name>, <name><surname>Hsu</surname><given-names>YL</given-names></name>, <year>2010</year>. <article-title>A review of accelerometry-based wearable motion detectors for physical activity monitoring</article-title>. <source>Sensors</source>
<volume>10</volume>, <fpage>7772</fpage>&#x02013;<lpage>7788</lpage>.<pub-id pub-id-type="pmid">22163626</pub-id></mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>Figure 1.</label><caption><p id="P27">The four sensor locations.</p></caption><graphic xlink:href="nihms-1856050-f0001" position="float"/></fig><fig position="float" id="F2"><label>Figure 2.</label><caption><p id="P28">Percentage of work time performing at least moderate PA as measured using <xref rid="R28" ref-type="bibr">Hildebrand et al. (2014)</xref> prediction of metabolic equivalents (METs) for the four different sensor locations.</p></caption><graphic xlink:href="nihms-1856050-f0002" position="float"/></fig><fig position="float" id="F3"><label>Figure 3.</label><caption><p id="P29">Summarized Bland-Altman plots for each sensor location, with linear regression lines and hyperbolic, 95% &#x0201c;prediction&#x0201d; limits. Pearson correlation coefficients assessing the strength of the proportional bias is presented in the upper left corner of each plot. Error bars represent standard errors of the mean of the averages and mean of the differences for each participant.</p></caption><graphic xlink:href="nihms-1856050-f0003" position="float"/></fig><table-wrap position="float" id="T1"><label>Table 1.</label><caption><p id="P30">The percentage of work time in each PA summary metric category [mean (SD)] by sensor location and results of one-way repeated measures analyses of variance.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th rowspan="2" align="left" valign="middle" colspan="1">Summary Metric</th><th colspan="4" align="center" valign="middle" rowspan="1">Sensor Location<hr/></th></tr><tr><th align="right" valign="middle" rowspan="1" colspan="1">Waist</th><th align="right" valign="middle" rowspan="1" colspan="1">Trunk</th><th align="right" valign="middle" rowspan="1" colspan="1">Left Arm</th><th align="right" valign="middle" rowspan="1" colspan="1">Right Arm</th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">Counts (% of work day)</td><td align="right" valign="middle" rowspan="1" colspan="1"/><td align="right" valign="middle" rowspan="1" colspan="1"/><td align="right" valign="middle" rowspan="1" colspan="1"/><td align="right" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">&#x02003;Sedentary<sup><xref rid="TFN2" ref-type="table-fn">A</xref></sup></td><td align="right" valign="middle" rowspan="1" colspan="1">34.9 (6.1)</td><td align="right" valign="middle" rowspan="1" colspan="1">29.3 (6.7)</td><td align="right" valign="middle" rowspan="1" colspan="1">12.8 (4.2)</td><td align="right" valign="middle" rowspan="1" colspan="1">11.4 (4.7)</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">&#x02003;Light <sup><xref rid="TFN3" ref-type="table-fn">B</xref></sup></td><td align="right" valign="middle" rowspan="1" colspan="1">58.2 (6.0)</td><td align="right" valign="middle" rowspan="1" colspan="1">64.6 (6.8)</td><td align="right" valign="middle" rowspan="1" colspan="1">78.9 (4.3)</td><td align="right" valign="middle" rowspan="1" colspan="1">79.6 (5.6)</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">&#x02003;Moderate <sup><xref rid="TFN3" ref-type="table-fn">B</xref></sup></td><td align="right" valign="middle" rowspan="1" colspan="1">7.0 (2.1)</td><td align="right" valign="middle" rowspan="1" colspan="1">6.1 (2.1)</td><td align="right" valign="middle" rowspan="1" colspan="1">8.4 (2.8)</td><td align="right" valign="middle" rowspan="1" colspan="1">9.0 (3.4)</td></tr><tr><td colspan="5" align="left" valign="middle" rowspan="1">
<hr/>
</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">METs (% of work day)</td><td align="right" valign="middle" rowspan="1" colspan="1"/><td align="right" valign="middle" rowspan="1" colspan="1"/><td align="right" valign="middle" rowspan="1" colspan="1"/><td align="right" valign="middle" rowspan="1" colspan="1"/></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">&#x02003;Light <sup><xref rid="TFN2" ref-type="table-fn">A</xref></sup></td><td align="right" valign="middle" rowspan="1" colspan="1">96.8 (1.5)</td><td align="right" valign="middle" rowspan="1" colspan="1">99.3 (0.6)</td><td align="right" valign="middle" rowspan="1" colspan="1">94.0 (3.3)</td><td align="right" valign="middle" rowspan="1" colspan="1">89.4 (5.0)</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">&#x02003;Moderate <sup><xref rid="TFN2" ref-type="table-fn">A</xref></sup></td><td align="right" valign="middle" rowspan="1" colspan="1">3.2 (1.5)</td><td align="right" valign="middle" rowspan="1" colspan="1">0.7 (0.6)</td><td align="right" valign="middle" rowspan="1" colspan="1">6.0 (3.3)</td><td align="right" valign="middle" rowspan="1" colspan="1">10.6 (5.0)</td></tr></tbody></table><table-wrap-foot><fn id="TFN1"><p id="P31"><italic toggle="yes">Note:</italic> The effect of sensor location on each summary metric was statistically significant (<italic toggle="yes">p</italic> &#x0003c;<italic toggle="yes">0.05</italic>).</p></fn><fn id="TFN2"><label>A</label><p id="P32">All post-hoc pairwise comparisons statistically significant with <italic toggle="yes">p</italic> &#x0003c;0.01.</p></fn><fn id="TFN3"><label>B</label><p id="P33">All post-hoc pairwise comparisons statistically significant with <italic toggle="yes">p</italic> &#x0003c;0.01 except the difference between the left and right arm sensor locations (<italic toggle="yes">p</italic> &#x0003e;<italic toggle="yes">0.05</italic>)</p></fn></table-wrap-foot></table-wrap><table-wrap position="float" id="T2"><label>Table 2.</label><caption><p id="P34">Bland-Altman results [mean bias (lower limit of agreement, upper limit of agreement)] for each 1-min epoch of observation by sensor location.</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th rowspan="2" align="left" valign="middle" colspan="1">Summary Metric</th><th colspan="3" align="center" valign="middle" rowspan="1">Sensor Location<hr/></th></tr><tr><th align="right" valign="middle" rowspan="1" colspan="1">Trunk</th><th align="right" valign="middle" rowspan="1" colspan="1">Left Arm</th><th align="right" valign="middle" rowspan="1" colspan="1">Right Arm</th></tr></thead><tbody><tr><td align="left" valign="middle" rowspan="1" colspan="1">Counts</td><td align="right" valign="middle" rowspan="1" colspan="1">&#x02212;8.3 (&#x02212;1298.8, 1282.2)</td><td align="right" valign="middle" rowspan="1" colspan="1">195.2 (&#x02212;676.2, 1066.7)</td><td align="right" valign="middle" rowspan="1" colspan="1">207.7 (&#x02212;906.7, 1322.1)</td></tr><tr><td align="left" valign="middle" rowspan="1" colspan="1">METs</td><td align="right" valign="middle" rowspan="1" colspan="1">&#x02212;0.16 (&#x02212;0.66, 0.35)</td><td align="right" valign="middle" rowspan="1" colspan="1">0.24 (&#x02212;0.22, 0.70)</td><td align="right" valign="middle" rowspan="1" colspan="1">0.35 (&#x02212;0.33, 1.00)</td></tr></tbody></table></table-wrap></floats-group></article>