<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.3 20210610//EN" "JATS-archivearticle1-3-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" dtd-version="1.3" xml:lang="en" article-type="research-article"><?properties manuscript?><processing-meta base-tagset="archiving" mathml-version="3.0" table-model="xhtml" tagset-family="jats"><restricted-by>pmc</restricted-by></processing-meta><front><journal-meta><journal-id journal-id-type="nlm-journal-id">101550009</journal-id><journal-id journal-id-type="pubmed-jr-id">38924</journal-id><journal-id journal-id-type="nlm-ta">J Test Eval</journal-id><journal-id journal-id-type="iso-abbrev">J Test Eval</journal-id><journal-title-group><journal-title>Journal of testing and evaluation</journal-title></journal-title-group><issn pub-type="ppub">0090-3973</issn><issn pub-type="epub">1945-7553</issn></journal-meta><article-meta><article-id pub-id-type="pmid">36147246</article-id><article-id pub-id-type="pmc">9490760</article-id><article-id pub-id-type="doi">10.1520/jte20180350</article-id><article-id pub-id-type="manuscript">HHSPA1835206</article-id><article-categories><subj-group subj-group-type="heading"><subject>Article</subject></subj-group></article-categories><title-group><article-title>Evaluation of Apparatus Used to Test Liquid through Protective Materials: Comparison of a Modified Dot-Blot Apparatus to the ASTM Penetration Cell</article-title></title-group><contrib-group><contrib contrib-type="author"><name><surname>Schwerin</surname><given-names>Matthew R.</given-names></name><xref rid="A1" ref-type="aff">1</xref></contrib><contrib contrib-type="author"><name><surname>Portnoff</surname><given-names>Lee</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-3768-9361</contrib-id><xref rid="A2" ref-type="aff">2</xref></contrib><contrib contrib-type="author"><name><surname>Furlong</surname><given-names>Jennifer L.</given-names></name><xref rid="A2" ref-type="aff">2</xref></contrib><contrib contrib-type="author"><name><surname>Das</surname><given-names>Srilekha S.</given-names></name><xref rid="A1" ref-type="aff">1</xref></contrib><contrib contrib-type="author"><name><surname>Gordon</surname><given-names>Edward A.</given-names></name><xref rid="A1" ref-type="aff">1</xref></contrib><contrib contrib-type="author"><name><surname>Woods</surname><given-names>Terry O.</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-4584-2012</contrib-id><xref rid="A1" ref-type="aff">1</xref></contrib><contrib contrib-type="author"><name><surname>Wood</surname><given-names>Steven C.</given-names></name><xref rid="A1" ref-type="aff">1</xref></contrib><contrib contrib-type="author"><name><surname>Lucas</surname><given-names>Anne D.</given-names></name><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-3938-9127</contrib-id><xref rid="A3" ref-type="aff">3</xref></contrib></contrib-group><aff id="A1"><label>1</label>Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD 20993, USA,</aff><aff id="A2"><label>2</label>The National Personal Protective Technology Laboratory, National Institute for Occupational Safety and Health, 626 Cochrans Mill Rd., Pittsburgh, PA 15236, USA,</aff><aff id="A3"><label>3</label>Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, MD 20993, USA</aff><author-notes><corresp id="CR1">(Corresponding author), <email>anne.lucas@fda.hhs.gov</email></corresp></author-notes><pub-date pub-type="nihms-submitted"><day>9</day><month>9</month><year>2022</year></pub-date><pub-date pub-type="ppub"><day>07</day><month>3</month><year>2019</year></pub-date><pub-date pub-type="pmc-release"><day>21</day><month>9</month><year>2022</year></pub-date><volume>48</volume><issue>1</issue><elocation-id>10.1520/jte20180350</elocation-id><abstract id="ABS1"><p id="P1">Personal protective equipment (PPE), such as gowns used in the latest Ebola outbreak in Western Africa, are critical in preventing the spread of deadly diseases. Appropriate test systems and test soils are needed to adequately evaluate PPE. ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link>, <italic toggle="yes">Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquid</italic>, has been used for decades to test fabrics&#x02019; resistance to liquid penetration. However, this test apparatus requires at least 60 mL of test solutions, is labor intensive, and has problems with leakage around the gaskets. We compared the F903 test apparatus to a modified dot-blot apparatus to evaluate the visual penetration of a blood test soil. A series of commercially available gowns and drapes were tested in each apparatus. Using blood test soil at 2 psi, there was no statistically significant difference between the two methods except for in one gown. By comparing this gown in the ASTM test apparatus with and without a screen, the particular screen selected did not account for the difference between the dot-blot and F903 apparatuses; however, it is conceivable that a particular screen/fabric combination could account for this difference. The modified dot-blot apparatus was evaluated using three different test solutions: blood, vomit, and a labeled protein (goat anti-rabbit immunoglobulin G&#x02013;horseradish peroxidase [GaR IgG-HRP]) in a blood test soil solution. This testing revealed significant difference in penetration for some of the PPE garments. The modified dot-blot had several large advantages over the ASTM apparatus&#x02014;over six times less specimen volume and no edge or gasket leakage. In addition, nitrocellulose can be easily incorporated into the modified dot-blot apparatus, enabling the trapping of viruses and proteins that penetrate PPE&#x02014;thus permitting the use of antibodies to quickly and sensitively detect penetration.</p></abstract><kwd-group><kwd>personal protective equipment</kwd><kwd>gowns</kwd><kwd>aprons</kwd><kwd>ASTM standards</kwd><kwd>virus (generic)</kwd><kwd>penetration testing</kwd></kwd-group></article-meta></front><body><sec id="S1"><title>Introduction</title><p id="P2">At the time the original ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link>, <italic toggle="yes">Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquids</italic>, ASTM <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link>, <italic toggle="yes">Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood</italic>, and ASTM <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link>, <italic toggle="yes">Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System</italic>, standards were written, from the mid-1980s to the mid-1990s, the pressing concern was to prevent exposure to HIV in blood.<sup><xref rid="R1" ref-type="bibr">1</xref></sup> ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link><sup><xref rid="R2" ref-type="bibr">2</xref></sup> is the general test system for penetration of liquids, ASTM <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link><sup><xref rid="R3" ref-type="bibr">3</xref></sup> is the specific application of this test system for a blood test soil, and ASTM <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link><sup><xref rid="R4" ref-type="bibr">4</xref></sup> is specific for bacteriophage penetration. However, concerns about infectious microbes and the physiological environment in which they may be present have expanded. For instance, in light of the recent outbreak of Ebola in Africa, testing of personal protective equipment (PPE) with viral surrogates in more clinically relevant test soils like vomit, fecal, and mucosal secretions has become a pressing need. To address these concerns, two clinically relevant test soils were selected to test in a modified dot-blot and ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test apparatus: an existing blood soil and a newly developed vomit soil.</p><p id="P3">PPE (e.g., drapes and gowns) are in the first line of defense for health-care workers who come in close proximity to viruses with devastating outcomes, like HIV and Ebola. Therefore, safety and effectiveness of these devices are critical to meeting the labeled performance claims for impermeability. Preventing health-care worker exposure is a crucial factor in sustaining the fight against infectious diseases. There is an array of standard methods for testing PPE,<sup><xref rid="R2" ref-type="bibr">2</xref>&#x02013;<xref rid="R11" ref-type="bibr">11</xref></sup> most dealing with a single isolated challenge. Additionally, ANSI/AAMI PB70, <italic toggle="yes">Liquid Barrier Performance and Classification of Protective Apparel and Drapes Intended for use in Health Care Facilities</italic>, specifies four different levels for PPE.<sup><xref rid="R11" ref-type="bibr">11</xref></sup> Level 1 is least protective (passing a water resistance test<sup><xref rid="R9" ref-type="bibr">9</xref></sup>); Level 4 is the highest level for gowns (passing a barrier test against viral challenges<sup><xref rid="R4" ref-type="bibr">4</xref></sup>).<sup><xref rid="R11" ref-type="bibr">11</xref></sup> Although viral tests developed in the 1990s in response to the HIV epidemic use a live surrogate virus, research has not confirmed the relative penetration of different types of viruses. Furthermore, the scope of the standard viral test methods (ASTM <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link> and ISO 16604, <italic toggle="yes">Clothing for Protection against Contact with Blood and Body Fluids</italic>&#x02014;<italic toggle="yes">Determination of the Resistance of Protective Clothing Materials to Penetration by Blood and Body Fluids</italic>&#x02014;<italic toggle="yes">Test Method Using Phi-X174 Bacteriophage</italic>) does not include comparison between different viruses. A body of relevant, standardized tests and test soils will assist both manufacturers and device regulators by providing specific standardized methods that can be used as is, saving time and the cost of developing new methods, allowing more straightforward comparison of different PPE tested using the standard methods, and ultimately speeding the entry of new devices to the market.</p><p id="P4">The liquid penetration test apparatus specified in ASTM test method <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> uses a large, heavy, and cumbersome setup (<xref rid="F1" ref-type="fig">fig. 1</xref>). False positives can occur from fabric being pinched at the perimeter of the apparatus. Also, results depend on the type of screen used.<sup><xref rid="R12" ref-type="bibr">12</xref></sup> The ASTM standards specify that the screen should be a smooth finished square mesh made of either metal or plastic, with an open area of at least 50 %.<sup><xref rid="R3" ref-type="bibr">3</xref>,<xref rid="R4" ref-type="bibr">4</xref></sup> This gives a wide range of potential variation and, because of this, ASTM Committee F23 is working to standardize the screen design (ASTM ballot item WK60738, 2017). The modified dot-blot is much smaller and lightweight (<xref rid="F2" ref-type="fig">fig. 2</xref>), has a simpler and easier setup that does not use screens, and does not have sharp edges that would cut into the test fabric. Additionally, this apparatus is not prone to leakage around the edges of the test cells because at the bottom of the sample well is an O-ring that, when clamped into place, seals the fabric between the well and the lower layers of blotting paper (<xref rid="F2" ref-type="fig">fig. 2</xref>).</p><p id="P5">Use of the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> apparatus requires a large volume (60 mL) of test solution, whereas the modified dot-blot apparatus uses much less (9.6 mL). This difference in test volume becomes significant if microorganisms are to be used to test the PPE. Propagating and plating large volumes of bacteriophage are labor intensive, requiring technical skill to prevent contamination, as well as three- or four-day blocks of time to sanitize equipment, grow the bacteriophage, run the viral penetration test on the PPE, and plate the penetrating solution onto its host <italic toggle="yes">Escherichia coli</italic>. The modified dot-blot can enable users to more quickly and easily test PPE materials in applications in which bacteriophage or virus surrogates are used as challenge organisms, because the nitrocellulose membrane (<xref rid="F2" ref-type="fig">fig. 2</xref>) traps proteins and virus, enabling quick and specific detection using antibodies rather than the more cumbersome and time-consuming traditional microbiological method.</p><p id="P6">Another drawback with the F903 apparatus is that the test result provides nonparametric, binary statistics (i.e., pass/fail). Statistical comparisons between two specimen groups are performed with a Mann&#x02013;Whitney-type test that may use hundreds or thousands of specimen to demonstrate differences.<sup><xref rid="R13" ref-type="bibr">13</xref></sup> In contrast, the dot-blot apparatus contains 96 wells that provide a greater specimen size for statistical comparison of uniform fabrics that have few imperfections across a large area of fabric.</p><p id="P7">The goals of this research were (1) to evaluate if there is any significant difference between penetration test results for the modified dot-blot apparatus and the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> apparatus using synthetic blood, (2) to determine if the presence of a screen in the F903 apparatus accounts for any significant difference between the two test methods, (3) to determine if a labeled protein (goat anti-rabbit immunoglobulin G&#x02013;horseradish peroxidase [GaR IgG-HRP]) is more sensitive than a visualization of the red dye used in the synthetic blood, and (4) to evaluate any difference between penetration test results for synthetic blood and an alternate test soil simulating vomit. The intent of this work is to investigate the test methods and not to assess the performance of specific PPE products.</p></sec><sec id="S2"><title>Materials and Methods</title><sec id="S3"><title>GOWNS AND DRAPES</title><p id="P8">Gowns, drapes, and one hospital curtain with different labeled levels of protection were obtained from commercially available sources. As the purpose of this study was to compare performance of test apparatus and procedures, not to evaluate different PPE materials, the materials and manufacturers are not mentioned.</p></sec><sec id="S4"><title>PPE TESTING APPARATUS</title><sec id="S5"><title>ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> Test Apparatus</title><p id="P9">This apparatus was constructed as detailed in ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link>, <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link>, and <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link> (<xref rid="F1" ref-type="fig">fig. 1</xref>). ASTM <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link> and <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link> specify the option of using a retaining screen. Both standards describe procedure A (without a retaining screen) and procedure B (with a retaining screen). Whenever specified in our testing, a type 304 stainless steel 16 by 16 wire mesh with 0.016-in. (0.04064-cm) diameter wire and 55.4 % clear opening (L.E. Jones Wire Cloth, Baltimore, MD) was used. High-temperature silicone gasket material, Durometer 60A, 1/16-in. (0.15875-cm) thick (McMaster-Carr, Robbinsville, NJ), was used in the assembly of the test cell.</p></sec><sec id="S6"><title>National Institute for Occupational Safety and Health Gasket/Screen</title><p id="P10">Screens may be designed to achieve different test results.<sup><xref rid="R12" ref-type="bibr">12</xref></sup> To help provide consistent results, National Institute for Occupational Safety and Health (NIOSH) developed a new screen that would standardize the screens used for viral penetration testing (<xref rid="F3" ref-type="fig">fig. 3</xref>). This new screen consists of a hexagon hole perforated screen encapsulated within a polytetrafluoroethylene ring gasket. The screen provided the test surface, with a 79 % open area. This gasket was adopted for testing after the first three runs with all fabric specimen due to the high failure rate of some specimens.</p></sec><sec id="S7"><title>Modified Dot-Blot Test Apparatus</title><p id="P11">A Whatman Schleicher &#x00026; Schuell Minifold I Dot-Blot, acrylic 96-well plate (<xref rid="F2" ref-type="fig">fig. 2</xref>) was modified. The filtration plate holes, initially around 1 mm in diameter, were drilled out to 5 mm, slightly smaller than the corresponding holes on the 96-sample well plate (<xref rid="F2" ref-type="fig">fig. 2</xref>). This was done to allow a larger area of the PPE material to be under vacuum. A vacuum gauge (EN 837&#x02013;1 WIKAI, Lawrenceville, GA) was used to establish and monitor the pressure on the fabric in this test setup. Otherwise, the apparatus was used as directed in the manual, with the portion of PPE to be tested placed between the nitrocellulose membrane and the sample well plate, as shown in <xref rid="F2" ref-type="fig">figure 2</xref>. The volume of test soils per well was 100 &#x003bc;L. Catastrophic failures were easy to detect in the dot-blot setup. As the test solution was pulled through the fabric and the nitrocellulose and blotting paper layers, the red dye in the synthetic blood was clearly visible in the vacuum plenum, and no solution was left in the sample wells. More subtle failures could only be visualized after dismantling the apparatus. Removal of any remaining liquid in the wells must be performed first to minimize cross contamination. This was accomplished with a multichannel pipette or a small handheld vacuum plate washer held at an angle so that the tips of the device removing the liquid did not touch the material being tested. The modified dot-blot apparatus could then be dismantled for visual examination.</p></sec></sec><sec id="S8"><title>CHEMICALS</title><p id="P12">Unless otherwise noted, chemicals were purchased from Sigma-Aldrich (St. Louis, MO). Water used in this experiment was purified by a Barnstead NANOpure Diamond water purification unit from Thermo Fisher Scientific (Rockford, IL).</p></sec><sec id="S9"><title>TEST SOILS</title><sec id="S10"><title>Vomit Test Soil</title><p id="P13">The development of a vomit test soil was undertaken after discussions with health-care workers who had been in Western Africa following the 2014 Ebola outbreak. In addition to blood, vomit was identified by the health-care workers as a likely fluid for transmission of the virus. Vomiting is the involuntary, forceful expulsion of stomach contents through the mouth and sometimes the nose.<sup><xref rid="R14" ref-type="bibr">14</xref></sup> The objective was to develop a reasonable test soil that would reflect the clinically relevant chemical components in human vomit. In individuals who are sick and vomiting over a period of time, the undigested food content of the stomach is no longer present. The basic composition of vomitus after undigested food is expelled is the gastric juices and bile.<sup><xref rid="R15" ref-type="bibr">15</xref>,<xref rid="R16" ref-type="bibr">16</xref></sup> Previous work on simulating stomach fluid to examine changes in bioavailability of metals<sup><xref rid="R17" ref-type="bibr">17</xref></sup> or changes in size and surface chemistry of nanoparticles<sup><xref rid="R17" ref-type="bibr">17</xref>,<xref rid="R18" ref-type="bibr">18</xref></sup> indicated that a combination of hydrochloric acid (HCl) and glycine (both 0.4 M) at a pH of 1.5 is a good approximation of stomach fluid. Some bile acid may be expected in vomit. A study of the amount of bile acids in fasting gastric aspirates shows a large range in bile concentration. We chose to use 0.4 g/L, which is at the upper end of the concentration observed by Hoare et al.<sup><xref rid="R19" ref-type="bibr">19</xref></sup> As human bile contains mucin,<sup><xref rid="R15" ref-type="bibr">15</xref></sup> 1 g/100 mL mucin was added to vomit test soil to mimic the sticky mucus characteristic. As the mucin is above saturation in this test soil, vigorous stirring or vortexing is necessary immediately prior to use. Amaranth dye (1 mg/mL) was added to aid in visualization of any vomit test soil penetration of PPE materials.</p></sec><sec id="S11"><title>Blood</title><p id="P14">The ISO 16603, <italic toggle="yes">Clothing for Protection against Contact with Blood and Body Fluids</italic>&#x02014;<italic toggle="yes">Determination of the Resistance of Protective Clothing Materials to Penetration by Blood and Body Fluids</italic>&#x02014;<italic toggle="yes">Test Method Using Synthetic Blood</italic>, blood test soil<sup><xref rid="R7" ref-type="bibr">7</xref></sup> was used in both the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> and dot-blot apparatuses. This blood test soil was chosen, as the chemicals needed to make the test soil were easily commercially available (<xref rid="T1" ref-type="table">Table 1</xref>). Because the surface tension of synthetic blood is inconsistent with time and handling,<sup><xref rid="R20" ref-type="bibr">20</xref></sup> the surface tension measurements of the blood test soil (<xref rid="T2" ref-type="table">Table 2</xref>) should not be interpreted as exact values.</p></sec><sec id="S12"><title>Subset of Blood</title><p id="P15">A labeled protein, GaR IgG-HRP (Sigma-Aldrich 1:10,000) was used as an alternate to the amaranth dye in the ISO 16603 blood test soil in the modified dot-blot apparatus. The nitrocellulose membrane, used in many applications, as it traps proteins, was used to retain the GaR IgG-HRP protein (<xref rid="F2" ref-type="fig">fig. 2</xref>). This protein was visualized with a one-component 3,3&#x02032;,5,5&#x02032;-tetramethylbenzidine membrane peroxidase substrate, which reacts with the HRP on the GaR IgG protein to create a colored precipitate, from Kirkegaard &#x00026; Perry Laboratories (Gaithersburg, MD), now SeraCare (Milford, MA). Some initial work was performed in attempting to use blotting paper and nitrocellulose in the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> apparatus, but because of expense and the bulging of some fabrics with no screen tore the nitrocellulose, this approach was abandoned.</p></sec></sec><sec id="S13"><title>CHARACTERIZATION OF THE TEST SOLUTIONS</title><sec id="S14"><title>Conductivity and pH</title><p id="P16">The conductivity and pH of test solutions were measured with a Mettler Toledo Seven Compact (Columbus, OH) and Hanna Instruments HI 8519N (Woonsocket, RI) meter, respectively.</p></sec><sec id="S15"><title>Viscosity</title><p id="P17">Viscosities of the test solutions were measured at 25&#x000b0;C under 0.1/s to 100/s shear rate using a standard cup and din rotor system in a rheometer (model AR G2, TA Instruments, New Castle, DE).</p></sec><sec id="S16"><title>Surface Tension</title><p id="P18">Surface tension was measured using both a capillary surface tension tensiometer (Cole-Parmer, Vernon Hills, IL) and a Du Nouy precision tensiometer (CSC Scientific Co., Fairfax, VA), used as per manufacturer instructions. Because of variable response over time with the Du Nouy tensiometer, only surface tension as measured by the capillary tensiometer is reported (<xref rid="T2" ref-type="table">Table 2</xref>).</p><p id="P19">The composition and methods to make the test soils used in this study are summarized in <xref rid="T1" ref-type="table">Table 1</xref>. Test soil pH, conductivity, surface tension, and viscosity are listed in <xref rid="T2" ref-type="table">Table 2</xref>.</p></sec></sec><sec id="S17"><title>STATISTICAL METHODS</title><sec id="S18"><title>Goal 1: ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> to Dot-Blot Comparison</title><p id="P20">Our first consideration was to account for the difference in area between the dot-blot and ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> apparatuses. If the fabric were perfectly uniform, a large-area test may provide the same results as a small-area test; however, fabric imperfections that manifest over a large area may not be found within a single dot-blot cell. As the diameter of the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> apparatus (57.3 mm) is larger than a dot-blot cell (5 mm), we calculated the number of dot-blot cells having the same area as the ASTM penetration cell: &#x003c0; (28.65 mm)<sup>2</sup> / &#x003c0; (2.5 mm)<sup>2</sup> = 131 cells. ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> defines a test specimen failure as any observed penetration, regardless of quantity or intensity. To compare to the dot-blot apparatus, when considering a group of 131 cells, any observed penetration in one or more cells was counted as a singular specimen failure.</p><p id="P21">To compare statistical differences, we chose a nonparametric, two-proportion z-test. An initial specimen size of <italic toggle="yes">n</italic> = 5 was used to screen for penetrable and non-penetrable fabrics. Considering the two-proportion z-test, if 5/5 passed apparatus &#x0201c;a&#x0201d; and 5/5 passed apparatus &#x0201c;b,&#x0201d; to show a significant difference between apparatuses at <italic toggle="yes">p</italic> = 0.05, the next four tests would need to all pass apparatus &#x0201c;a&#x0201d; while four consecutive tests fail in apparatus &#x0201c;b.&#x0201d; We consider this scenario sufficiently improbable; therefore, in lieu of conducting nine tests on each apparatus, if all five passed (or all five failed), the apparatuses were not significantly different.</p><p id="P22">If the first five tests had a mixture of results, the specimen size was increased to <italic toggle="yes">n</italic> = 25. This specimen size is large enough to detect a moderate difference in proportions as significant. Given that small differences are not scientifically meaningful, we deem this specimen size as appropriate, with consideration of the time and expense of the analysis.</p></sec><sec id="S19"><title>Goal 2: Screen Effect</title><p id="P23">The ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test method specifies that if a fabric stretches more than 5 mm during the test, a screen may be used to limit distention of the specimen. Limiting fabric stretching can improve the performance. Because the modified dot-blot apparatus is comprised of many small diameter tests with O-rings that press into the fabric, which is supported by blotting paper, a screen is not used, as there is no distension. Because of these spatial differences, we hypothesize that if the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> and modified dot-blot apparatuses obtain different results, the difference could be mitigated by the use of a screen. Fabrics in which the test method obtained statistically different results using ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> without a screen compared with the modified dot-blot method were then evaluated with a two-proportion z-test to compare the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test with a screen against the dot-blot apparatus.</p></sec><sec id="S20"><title>Goals 3 and 4: Labeled Protein (GaR IgG-HRP) and Vomit Test Soil versus Blood</title><p id="P24">The dot-blot apparatus was selected for these comparisons because it requires a smaller volume of test fluid and provides a greater number of specimens to calculate a z-score. A specimen size of seven tests (each having 96 cells) was selected for an <italic toggle="yes">n</italic> = 672. For the synthetic blood soil, 34 tests had been run for some of the fabrics. The first 7 of the 34 tests were selected for statistical analysis.</p></sec></sec></sec><sec id="S21"><title>Results</title><sec id="S22"><title>APPARATUS EVALUATION</title><sec id="S23"><title>Goals 1 and 2: Comparison of ASTM and Dot-Blot Apparatuses</title><p id="P25"><xref rid="T3" ref-type="table">Table 3</xref> details a comparison of the ASTM apparatus with the dot-blot using the ISO 10663 blood test soil at 2 psi. P (Pass) indicates that no visual dye penetration was observed and F (Fail) indicates there was visual dye penetration. Only gown #3 showed a significant difference (<italic toggle="yes">p</italic> &#x0003c; 0.05) between the ASTM and the dot-blot apparatus. Gowns #2 and #4 did not show significant difference (<italic toggle="yes">p</italic> &#x0003c; 0.05) between the ASTM and dot-blot apparatuses.</p><p id="P26">Because the type of apparatus used (i.e., ASTM or dot-blot) was different for gown #3, that gown was evaluated with the ASTM apparatus using a screen. For gown #3, 96 % of the specimens (33/34 or 24/25) passed using the dot-blot apparatus, whereas 60 % (15/25) passed using the ASTM apparatus with a screen, and only 28 % (7/25) passed using the ASTM apparatus without a screen. Although less than the dot-blot and ASTM without a screen, the difference between the dot-blot and ASTM with screen was still significant (<italic toggle="yes">p</italic> &#x0003c; 0.05), with a z-score of 3.0725 and <italic toggle="yes">p</italic>-value of 0.00214.</p><p id="P27"><xref rid="T4" ref-type="table">Table 4</xref> shows the results of PPE testing using the dot-blot apparatus for the International Standards Organization (ISO)<sup><xref rid="R7" ref-type="bibr">7</xref></sup> blood test soil with dye, ISO blood test soil without dye but with the labeled protein (GaR IgG-HRP), and vomit test soils. Specimens of all fabric were run with seven 96-well plates at 2 psi except fabrics specimens 2, 3, and 4, which were run with 34 of the 96-well plates for the ISO blood soil (only the first seven of these runs were used for this comparison). The results of the different test soils used with the dot-blot apparatus were converted to the number of individual wells that passed the test soil challenge (7 tests &#x000d7; 96 wells per test =672 wells total). Statistical comparison of the different test soils for fabrics 1&#x02013;4, 6, and 7 are delineated on the right. These data indicate that vomit test soil generates more failures than blood alone and that the labeled protein (GaR IgG-HRP) can be a more sensitive indicator of material penetration than the dye in the blood test soil.</p></sec></sec></sec><sec id="S24"><title>Discussion</title><p id="P28">A dot-blot is a technique initially used in molecular biology to detect proteins; it is a simplified version of western blotting. In addition to proteins, the dot-blot apparatus has been used to detect a variety of different compounds of interest, including viruses. The test apparatus is relatively simple and easy to use. There is a bottom plate, the filtration plate, with holes that match the 96 wells of the sample well plate (<xref rid="F2" ref-type="fig">fig. 2</xref>). The holes on the filtration plate are smaller than the sample well plate. Blotting paper is place on the lower filtration plate, and the PPE material is placed on the blotting paper. The apparatus is then clamped together, so that there are 96 wells with the PPE material clamped at the bottom of the well. Now, test solutions such as synthetic blood or vomit can be placed in each well, and the ability of the PPE material to resist penetration of the test solution can be evaluated. In the case in which we wish to trap proteins, such as the GaR-HRP, a sheet of nitrocellulose is placed between the blotting paper and the PPE. Any proteins (in this case, GaR-HRP) passing through the PPE material are trapped on the nitrocellulose membrane. In the absence of airflow within the dot-blot apparatus, the pressure is hydrostatic (i.e., equal in all wells, regardless of well size or position). As ASTM <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link> states, pressure was added slowly to the system<sup><xref rid="R3" ref-type="bibr">3</xref></sup>; the application of a vacuum to the modified dot-blot mirrored this requirement.</p><p id="P29">This initial study comparing the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test apparatus with a modified dot-blot apparatus (Goal 1) demonstrated that there is statistically no difference between the two test setups at 2 psi when using a blood test soil for all but one (gown #3) of the 13 tested PPE fabrics specimens. Use of a screen did not change the result for gown #3, with the dot-blot significantly different from the ASTM apparatus with the screen, also. Notably, the use of a screen for this particular gown resulted in a doubling of the number of specimens that passed the penetration test.</p><p id="P30">There is a higher percentage of failures with the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test apparatus than with the modified dot-blot. This could be due, at least in part, to the vertical orientation of the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test apparatus, in which gravitational force adds 0.1 psi of pressure to the bottom of the test specimen. An additional problem with the ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> test apparatus was the tendency of soil to penetrate at the gasket, both with and without the presence of a screen. More penetration was seen at the gasket when certain types of screen were used; thus, the failure may not be due to the material but the failure of the gasket to appropriately seal the test specimen.</p><p id="P31">In contrast, the modified dot-blot test apparatus has some significant advantages. The problems with gasket and edge leakage were not seen with the dot-blot. Previous work by Nandy et al. clearly demonstrated that visual dye alone is often not as sensitive as other detection methods, so a method that also incorporates the identification of a penetrating microorganism is highly desirable.<sup><xref rid="R21" ref-type="bibr">21</xref></sup> The dot-blot method uses smaller amounts of liquid, which is a great advantage when microorganisms (bacteriophage) are used in the test system, as growing large volumes of microorganisms can be very labor and time intensive. In addition, nitrocellulose can be easily incorporated into this test system, allowing for proteins and viruses to be trapped and then antibodies to be used in the detection step. The utility of having one test for drapes using a blood test soil with dye (F1670) and a separate test for gowns using a bacteriophage (F1671) needs to be reevaluated. Work addressing this issue is ongoing. It may be possible to develop one optimized method that may be used for both applications. Furthermore, both the effort and time required to use an antibody to detect the presence of a bacteriophage or viral surrogate are substantially less than what is required to plate the bacteriophage on a bacterial lawn and wait days for plaques to form. In future studies, the use of a labeled protein (GaR IgG-HRP), a fluorescent chemical, or particle may prove to be a more reliable means of detecting penetration of PPE material than either dye or viruses.</p><p id="P32">This study did have its limitations. Initial runs with a simple screen and gaskets leaked; however, when using the gaskets and screens designed by NIOSH, most of this type of problem was alleviated. Most of the work in this study had been completed prior to receiving the new screens and gaskets designed by NIOSH. Although the use of a screen for gown #3 resulted in a doubling of the number of specimens that passed the penetration test, more testing would be helpful to compare different fabrics and different screen types. Finally, to validate the dot-blot apparatus, a carefully constructed round-robin with several participants would be needed.</p><p id="P33">The test setups used here provide information on the penetration of test solutions on various PPE materials; however, the question of how well these materials may perform in the field needs to be addressed. In addition to saturation level,<sup><xref rid="R22" ref-type="bibr">22</xref></sup> application of realistic test soils, such as vomit, may alter the ability of viruses to penetrate PPE materials. Adding realistic pressures or stresses to the PPE material while testing for penetration is another area that needs to be investigated.<sup><xref rid="R23" ref-type="bibr">23</xref></sup> The work described here provides information that can be used in the development of new and revised test methods for determining viral penetration of PPE material. These methods will provide manufacturers with standard, well-defined means of assessing PPE material penetration and assist the Food and Drug Administration (FDA) in evaluating claims for gowns and materials intended to protect against deadly viruses, enabling more straightforward comparisons and results for different gowns or other PPE, thereby reducing the time to review a new application, and providing health-care workers and the public access to new devices more quickly.</p></sec></body><back><ack id="S25"><title>ACKNOWLEDGMENTS</title><p id="P34">This project was initiated by a Reseach Collaboration Agreement (RCA) between the FDA and NIOSH and was supported in part by an appointment to the Research Participation Program at the Center for Device and Radiological Heath, administered by the Oak Ridge Institute for Science and Education through an interagency agreement between the U.S. Department of Energy and the U.S. FDA. Additionally, this project was funded by the FDA&#x02019;s Medical Counter Measures (MCMi) program.</p><p id="P35">The mention of commercial products, their sources, or their use in connection with material reported herein is not to be construed as either an actual or implied endorsement of such products by the Department of Health and Human Services or NIOSH, Centers for Disease Control and Prevention. The findings and conclusions in this article are those of the author(s) have not been formally disseminated by the U.S. FDA nor NIOSH, Centers for Disease Control and Prevention, and should not be construed to represent any agency determination or policy.</p></ack><ref-list><title>References</title><ref id="R1"><label>1.</label><mixed-citation publication-type="journal"><name><surname>L Belkin</surname><given-names>N</given-names></name>, &#x0201c;<article-title>The New American Society for Testing and Materials Tests: All That Glitters is not Gold</article-title>,&#x0201d; <source>American Journal of Infection Control</source>
<volume>22</volume>, no. <issue>3</issue> (<month>June</month>
<year>1994</year>): <fpage>172</fpage>&#x02013;<lpage>176</lpage>, <pub-id pub-id-type="doi">10.1016/0196-6553(94)90006-X</pub-id><pub-id pub-id-type="pmid">7943928</pub-id></mixed-citation></ref><ref id="R2"><label>2.</label><mixed-citation publication-type="book"><source>Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Liquid</source>, <comment>ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link></comment> (<year>2018</year>) (<publisher-loc>West Conshohocken, PA</publisher-loc>: <publisher-name>ASTM International</publisher-name>). <pub-id pub-id-type="doi">10.1520/F0903-18</pub-id></mixed-citation></ref><ref id="R3"><label>3.</label><mixed-citation publication-type="book"><source>Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood</source>, <comment>ASTM <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link>/F1670M</comment> (<year>2017</year>) (<publisher-loc>West Conshohocken, PA</publisher-loc>: <publisher-name>ASTM International</publisher-name>). <pub-id pub-id-type="doi">10.1520/F1670_F1670M-17A</pub-id></mixed-citation></ref><ref id="R4"><label>4.</label><mixed-citation publication-type="book"><source>Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174 Bacteriophage Penetration as a Test System</source>, <comment>ASTM <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link>/F1671M</comment> (<year>2013</year>) (<publisher-loc>West Conshohocken, PA</publisher-loc>: <publisher-name>ASTM International</publisher-name>). <pub-id pub-id-type="doi">10.1520/F1671_F1671M-13</pub-id></mixed-citation></ref><ref id="R5"><label>5.</label><mixed-citation publication-type="book"><source>Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities</source>, <comment>ASTM <ext-link xlink:href="https://www.astm.org/standards/f2407" ext-link-type="uri">F2407</ext-link>&#x02013;06</comment>(<year>2013</year>)<fpage>e1</fpage> (<publisher-loc>West Conshohocken, PA</publisher-loc>: <publisher-name>ASTM International</publisher-name>). <pub-id pub-id-type="doi">10.1520/F2407-06R13E01</pub-id></mixed-citation></ref><ref id="R6"><label>6.</label><mixed-citation publication-type="book"><source>Standard Test Method for Resistance of Materials Used in Protective Clothing to Penetration by Synthetic Blood Using a Mechanical Pressure Technique</source>, <comment>ASTM <ext-link xlink:href="https://www.astm.org/standards/f1819" ext-link-type="uri">F1819</ext-link>&#x02013;07</comment> (<year>2013</year>) (<publisher-loc>West Conshohocken, PA</publisher-loc>: <publisher-name>ASTM International</publisher-name>). <pub-id pub-id-type="doi">10.1520/F1819-07R13</pub-id></mixed-citation></ref><ref id="R7"><label>7.</label><mixed-citation publication-type="book"><source>Clothing for Protection against Contact with Blood and Body Fluids &#x02013; Determination of the Resistance of Protective Clothing Materials to Penetration by Blood and Body Fluids &#x02013; Test Method Using Synthetic Blood</source>, <comment>ISO 16603</comment> (<year>2004</year>) (<publisher-loc>Geneva Switzerland</publisher-loc>: <publisher-name>International Standards Organization</publisher-name>). <comment><ext-link xlink:href="http://www.iso.org" ext-link-type="uri">www.iso.org</ext-link></comment></mixed-citation></ref><ref id="R8"><label>8.</label><mixed-citation publication-type="book"><source>Clothing for Protection against Contact with Blood and Body Fluids &#x02013; Determination of the Resistance of Protective Clothing Materials to Penetration by Blood and Body Fluids &#x02013; Test Method Using Phi-X174 Bacteriophage</source>, <comment>ISO 16604</comment> (<year>2004</year>) (<publisher-loc>Geneva Switzerland</publisher-loc>: <publisher-name>International Standards Organization</publisher-name>). <comment><ext-link xlink:href="http://www.iso.org" ext-link-type="uri">www.iso.org</ext-link></comment></mixed-citation></ref><ref id="R9"><label>9.</label><mixed-citation publication-type="book"><source>Water Resistance: Impact Penetration Test</source>, <comment>TM042-TM42-TM 42</comment> (<year>2013</year>) (<publisher-loc>Research Triangle Park, NC</publisher-loc>: <publisher-name>American Association of Textile Chemists and Colorists</publisher-name>). <comment><ext-link xlink:href="http://www.aatcc.org" ext-link-type="uri">www.aatcc.org</ext-link></comment></mixed-citation></ref><ref id="R10"><label>10.</label><mixed-citation publication-type="book"><source>Water Resistance: Hydrostatic Pressure Test</source>, <comment>AATCC TM127</comment>(<year>2014</year>) (<publisher-loc>Research Triangle Park, NC</publisher-loc>: <publisher-name>American Association of Textile Chemists and Colorists</publisher-name>. <comment><ext-link xlink:href="http://www.aatcc.org" ext-link-type="uri">www.aatcc.org</ext-link></comment></mixed-citation></ref><ref id="R11"><label>11.</label><mixed-citation publication-type="book"><source>Liquid Barrier Performance and Classification of Protective Apparel and Drapes Intended for use in Health Care Facilities</source>, <comment>ANSI/AAMI PB70</comment>(<year>2012</year>) (<publisher-loc>Arlington, VA</publisher-loc>: <publisher-name>Association for the Advancement of Medical Instrumentation</publisher-name>). <comment><ext-link xlink:href="http://www.aami.org" ext-link-type="uri">www.aami.org</ext-link></comment></mixed-citation></ref><ref id="R12"><label>12.</label><mixed-citation publication-type="journal"><name><surname>Kisielewski</surname><given-names>RW</given-names></name>, <name><surname>Routson</surname><given-names>LB</given-names></name>, <name><surname>Chaput</surname><given-names>MP</given-names></name>, and <name><surname>Lytle</surname><given-names>CD</given-names></name>, &#x0201c;<article-title>Modification of ASTM F1671&#x02013;97a, Resistance of Materials to Penetration by Blood-Borne Pathogens, for Use with Elastomeric Materials</article-title>,&#x0201d; <source>Journal of Testing and Evaluation</source>
<volume>28</volume>, no. <issue>2</issue> (<month>March</month>
<year>2000</year>): <fpage>136</fpage>&#x02013;<lpage>138</lpage>, <pub-id pub-id-type="doi">10.1520/JTE12087J</pub-id></mixed-citation></ref><ref id="R13"><label>13.</label><mixed-citation publication-type="journal"><name><surname>Zhao</surname><given-names>YD</given-names></name>, <name><surname>Rahardja</surname><given-names>D</given-names></name>, and <name><surname>Qu</surname><given-names>Y</given-names></name>, &#x0201c;<article-title>Sample Size Calculation for the Wilcoxon&#x02013;Mann&#x02013;Whitney Test Adjusting for Ties</article-title>,&#x0201d; <source>Statistics in Medicine</source>
<volume>27</volume>, no. <issue>3</issue> (<month>May</month>
<year>2008</year>): <fpage>462</fpage>&#x02013;<lpage>468</lpage>, <pub-id pub-id-type="doi">10.1002/sim.2912</pub-id><pub-id pub-id-type="pmid">17487941</pub-id></mixed-citation></ref><ref id="R14"><label>14.</label><mixed-citation publication-type="book"><name><surname>Tintinalli</surname><given-names>JE</given-names></name>, &#x0201c;<part-title>Nausea and Vomiting</part-title>,&#x0201d; in <source>Emergency Medicine: A Comprehensive Study Guide</source>, (<publisher-loc>New York, NY</publisher-loc>: <publisher-name>McGraw-Hill Companies</publisher-name>, <year>2010</year>), <fpage>830</fpage>.</mixed-citation></ref><ref id="R15"><label>15.</label><mixed-citation publication-type="book"><name><surname>Hawk</surname><given-names>PB</given-names></name>, &#x0201c;<part-title>Gastric Digestion and Analysis</part-title>,&#x0201d; in <source>Hawk&#x02019;s Physiological Chemistry</source>, <name><surname>Oser</surname><given-names>BL</given-names></name>, ed. (<publisher-loc>New York NY</publisher-loc>: <publisher-name>McGraw-Hill</publisher-name>, <year>1965</year>), <fpage>466</fpage>&#x02013;<lpage>500</lpage>.</mixed-citation></ref><ref id="R16"><label>16.</label><mixed-citation publication-type="book"><name><surname>Kelley</surname><given-names>ME</given-names></name>, <name><surname>Brauning</surname><given-names>SE</given-names></name>, <name><surname>Schoof</surname><given-names>RA</given-names></name>, and <name><surname>Ruby</surname><given-names>MV</given-names></name>, &#x0201c;<part-title>Design/Conducting a Bioavailability Study</part-title>,&#x0201d; in <source>Assessing Oral Bioavailability of Metals in Soil</source> (<publisher-loc>Columbus, OH</publisher-loc>: <publisher-name>Battelle Press</publisher-name>, <year>2002</year>), <fpage>17</fpage>&#x02013;<lpage>88</lpage>.</mixed-citation></ref><ref id="R17"><label>17.</label><mixed-citation publication-type="journal"><name><surname>Rogers</surname><given-names>KR</given-names></name>, <name><surname>Bradham</surname><given-names>K</given-names></name>, <name><surname>Tolaymat</surname><given-names>T</given-names></name>, <name><surname>Thomas</surname><given-names>DJ</given-names></name>, <name><surname>Hartmann</surname><given-names>T</given-names></name>, <name><surname>Ma</surname><given-names>L</given-names></name>, and <name><surname>Williams</surname><given-names>A</given-names></name>, &#x0201c;<article-title>Alterations in Physical State of Silver Nanoparticles Exposed to Synthetic Human Stomach Fluid</article-title>,&#x0201d; <source>Science of the Total Environment</source>
<volume>420</volume> (<month>March</month>
<year>2012</year>): <fpage>334</fpage>&#x02013;<lpage>339</lpage>, <pub-id pub-id-type="doi">10.1016/j.scitotenv.2012.01.044</pub-id><pub-id pub-id-type="pmid">22330420</pub-id></mixed-citation></ref><ref id="R18"><label>18.</label><mixed-citation publication-type="journal"><name><surname>Mwilu</surname><given-names>SK</given-names></name>, <name><surname>El Badawy</surname><given-names>AM</given-names></name>, <name><surname>Bradham</surname><given-names>K</given-names></name>, <name><surname>Nelson</surname><given-names>C</given-names></name>, <name><surname>Thomas</surname><given-names>D</given-names></name>, <name><surname>Scheckel</surname><given-names>KG</given-names></name>, <name><surname>Tolaymat</surname><given-names>T</given-names></name>, <name><surname>Ma</surname><given-names>L</given-names></name>, and <name><surname>Rogers</surname><given-names>KR</given-names></name>, &#x0201c;<article-title>Changes in Silver Nanoparticles Exposed to Human Synthetic Stomach Fluid: Effects of Particle Size and Surface Chemistry</article-title>,&#x0201d; <source>Science of the Total Environment</source>
<volume>447</volume> (<month>March</month>
<year>2013</year>): <fpage>90</fpage>&#x02013;<lpage>98</lpage>, <pub-id pub-id-type="doi">10.1016/j.scitotenv.2012.12.036</pub-id><pub-id pub-id-type="pmid">23376520</pub-id></mixed-citation></ref><ref id="R19"><label>19.</label><mixed-citation publication-type="journal"><name><surname>Hoare</surname><given-names>AM</given-names></name>, <name><surname>Keighley</surname><given-names>MR</given-names></name>, <name><surname>Starkey</surname><given-names>B</given-names></name>, and <name><surname>Alexander-Williams</surname><given-names>J</given-names></name>, &#x0201c;<article-title>Measurement of Bile Acids in Fasting Gastric Aspirates: An Objective Test for Bile Reflux after Gastric Surgery</article-title>,&#x0201d; <source>Gut</source>
<volume>19</volume>, no. <issue>3</issue> (<month>March</month>
<year>1978</year>): <fpage>166</fpage>&#x02013;<lpage>169</lpage>, <pub-id pub-id-type="doi">10.1136/gut.19.3.166</pub-id><pub-id pub-id-type="pmid">631636</pub-id></mixed-citation></ref><ref id="R20"><label>20.</label><mixed-citation publication-type="journal"><name><surname>Portnoff</surname><given-names>L</given-names></name>, <name><surname>Jaques</surname><given-names>PA</given-names></name>, and <name><surname>Furlong</surname><given-names>JL</given-names></name>, &#x0201c;<article-title>The Surface Tension of Synthetic Blood used for ASTM F1670 Penetration Tests</article-title>,&#x0201d; <source>Journal of Testing and Evaluation</source>
<volume>47</volume>, no. <issue>2</issue> (<month>March</month>
<year>2019</year>), <pub-id pub-id-type="doi">10.1520/JTE20170285</pub-id></mixed-citation></ref><ref id="R21"><label>21.</label><mixed-citation publication-type="journal"><name><surname>Nandy</surname><given-names>P</given-names></name>, <name><surname>Young</surname><given-names>M</given-names></name>, <name><surname>Haugen</surname><given-names>SP</given-names></name>, <name><surname>Katzenmeyer-Pleuss</surname><given-names>K</given-names></name>, <name><surname>Gordon</surname><given-names>EA</given-names></name>, <name><surname>Retta</surname><given-names>SM</given-names></name>, <name><surname>Wood</surname><given-names>SC</given-names></name>, and <name><surname>Lucas</surname><given-names>AD</given-names></name>, &#x0201c;<article-title>Evaluation of One-way Valves for Use in Medical Devices</article-title>,&#x0201d; <source>American Journal of Infection Control</source>
<volume>45</volume>, no. <issue>7</issue> (<month>July</month>
<year>2017</year>): <fpage>793</fpage>&#x02013;<lpage>798</lpage>, <pub-id pub-id-type="doi">10.1016/j.ajic.2017.02.015</pub-id><pub-id pub-id-type="pmid">28359612</pub-id></mixed-citation></ref><ref id="R22"><label>22.</label><mixed-citation publication-type="journal"><name><surname>Nikiforuk</surname><given-names>AM</given-names></name>, <name><surname>Cutts</surname><given-names>TA</given-names></name>, <name><surname>Theriault</surname><given-names>SS</given-names></name>, and <name><surname>Cook</surname><given-names>BW</given-names></name>, &#x0201c;<article-title>Challenge of Liquid Stressed Protective Materials and Environmental Persistence of Ebola Virus</article-title>,&#x0201d; <source>Scientific Reports</source>
<volume>7</volume> (<month>June</month>
<year>2017</year>): <comment>article no.</comment>
<fpage>4388</fpage>, <pub-id pub-id-type="doi">10.1038/s41598-017-04137-2</pub-id><pub-id pub-id-type="pmid">28663587</pub-id></mixed-citation></ref><ref id="R23"><label>23.</label><mixed-citation publication-type="journal"><name><surname>Jaques</surname><given-names>PA</given-names></name>, <name><surname>Gao</surname><given-names>P</given-names></name>, <name><surname>Kilinc-Balci</surname><given-names>S</given-names></name>, <name><surname>Portnoff</surname><given-names>L</given-names></name>, <name><surname>Weible</surname><given-names>R</given-names></name>, <name><surname>Horvatin</surname><given-names>M</given-names></name>, <name><surname>Strauch</surname><given-names>A</given-names></name>, and <name><surname>Shaffer</surname><given-names>R</given-names></name>, &#x0201c;<article-title>Evaluation of Gowns and Coveralls Used by Medical Personnel Working with Ebola Patients against Simulated Bodily Fluids Using an Elbow Lean Test</article-title>,&#x0201d; <source>Journal of Occupational and Environmental Hygiene</source>
<volume>13</volume>, no. <issue>11</issue> (<month>November</month>
<year>2016</year>): <fpage>881</fpage>&#x02013;<lpage>893</lpage>, <pub-id pub-id-type="doi">10.1080/15459624.2016.1186279</pub-id><pub-id pub-id-type="pmid">27171285</pub-id></mixed-citation></ref></ref-list></back><floats-group><fig position="float" id="F1"><label>FIG. 1</label><caption><p id="P36">The ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> setup used in this study; it was originally designed for ASTM <ext-link xlink:href="https://www.astm.org/standards/f903" ext-link-type="uri">F903</ext-link> and also used in ASTM <ext-link xlink:href="https://www.astm.org/standards/f1670" ext-link-type="uri">F1670</ext-link> and ASTM <ext-link xlink:href="https://www.astm.org/standards/f1671" ext-link-type="uri">F1671</ext-link>. The size of the box housing the test cell is 42 by 32 by 40 cm.</p></caption><graphic xlink:href="nihms-1835206-f0001" position="float"/></fig><fig position="float" id="F2"><label>FIG. 2</label><caption><p id="P37">Modified dot-blot apparatus. The sample well plate contains 96 wells; all wells were used for testing in this study. For trapping the labeled protein, GaR IgG-HRP, nitrocellulose was used. For simple visualization of dye penetration, the nitrocellulose was not necessary. The size of this test apparatus is 13.5 by 10 by 7 cm.</p></caption><graphic xlink:href="nihms-1835206-f0002" position="float"/></fig><fig position="float" id="F3"><label>FIG. 3</label><caption><p id="P38">NIOSH retaining screen and gasket.</p></caption><graphic xlink:href="nihms-1835206-f0003" position="float"/></fig><table-wrap position="float" id="T1"><label>TABLE 1</label><caption><p id="P39">Composition of test soils used in this study</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1">Test Soils</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Blood test soil<sup><xref rid="R7" ref-type="bibr">7</xref></sup>:<break/>In 500 mL DD water, add slowly while stirring, 2 g carboxymethylcellulose.<break/>Add 1.2 g KH<sub>2</sub>PO<sub>4</sub> and 4.3 g Na<sub>2</sub>HPO<sub>4</sub>,<break/>4 mL of 1 % Tween 20 solution (in DD water),<break/>1 g Amaranth,<break/>2.4 g NaCl.<break/>Bring to 1 L using DD water.</td></tr><tr style="border-top: solid 1px"><td align="left" valign="top" rowspan="1" colspan="1">Labeled protein test soil:<break/>Made exactly the same as the blood test soil, but no Amaranth is added&#x02014;the dye would interfere with visualizing the HRP substrate.<break/>Prior to using this test soil, add 1:10,000 dilution of a commercially available secondary antibody, GaR IgG-HRP.</td></tr><tr style="border-top: solid 1px"><td align="left" valign="top" rowspan="1" colspan="1">Vomit test soil:<break/>0.4 M glycine,<break/>0.04 g bile salt,<break/>1 g mucin (not 100 % soluble, must mix well to make suspension before use).<break/>Bring to about 95 mL with DD water. Stir overnight.<break/>The next day, add 3&#x02013;4 mL of concentrated HCl (about 12 M) to bring to pH 1.5.<break/>Bring to 100 mL.</td></tr></tbody></table><table-wrap-foot><fn id="TFN1"><p id="P40"><italic toggle="yes">Note</italic>: DD = distilled, deionized.</p></fn></table-wrap-foot></table-wrap><table-wrap position="float" id="T2"><label>TABLE 2</label><caption><p id="P41">Test soil properties</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1">Test Soil</th><th align="center" valign="middle" rowspan="1" colspan="1">pH</th><th align="center" valign="middle" rowspan="1" colspan="1">Conductivity</th><th align="center" valign="middle" rowspan="1" colspan="1">Viscosity, Pa/s</th><th align="center" valign="middle" rowspan="1" colspan="1">Surface Tension, dyne/cm</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Synthetic Blood</td><td align="center" valign="top" rowspan="1" colspan="1">7.32</td><td align="center" valign="top" rowspan="1" colspan="1">10.89</td><td align="center" valign="top" rowspan="1" colspan="1">2.54&#x02013;2.55</td><td align="center" valign="top" rowspan="1" colspan="1">62.2</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Vomit</td><td align="center" valign="top" rowspan="1" colspan="1">1.49</td><td align="center" valign="top" rowspan="1" colspan="1">49.38</td><td align="center" valign="top" rowspan="1" colspan="1">1.92&#x02013;2.05</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr></tbody></table><table-wrap-foot><fn id="TFN2"><p id="P42"><italic toggle="yes">Note</italic>: The surface tension was measured using the capillary method immediately after mixing the synthetic blood or vomit test soil. Surface tension was not measured for vomit, as it is not a true solution.</p></fn></table-wrap-foot></table-wrap><table-wrap position="float" id="T3"><label>TABLE 3</label><caption><p id="P43">Comparison of the ASTM apparatus with the dot-blot using the ISO 10663 blood test soil at 2 psi for a series of gowns and drapes</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="middle" rowspan="1" colspan="1">Fabric</th><th align="center" valign="middle" rowspan="1" colspan="1">Level</th><th align="center" valign="middle" rowspan="1" colspan="1">ASTM No Screen</th><th align="center" valign="middle" rowspan="1" colspan="1">ASTM Screen</th><th colspan="2" align="center" valign="middle" rowspan="1">Dot-Blot</th><th align="center" valign="middle" rowspan="1" colspan="1">No Screen versus Screen (<italic toggle="yes">p</italic> &#x02264; 0.05)</th><th align="center" valign="middle" rowspan="1" colspan="1">No Screen versus Dot-Blot<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup> (<italic toggle="yes">p</italic> &#x02264; 0.05)</th><th align="center" valign="middle" rowspan="1" colspan="1">Screen versus Dot-Blot<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup> (<italic toggle="yes">p</italic> &#x02264; 0.05)</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 1</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">7/7</td><td align="center" valign="top" rowspan="1" colspan="1">(5/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 2</td><td align="center" valign="top" rowspan="1" colspan="1">3</td><td align="center" valign="top" rowspan="1" colspan="1">1/25</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">10/34</td><td align="center" valign="top" rowspan="1" colspan="1">(5/25)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 3</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">7/25</td><td align="center" valign="top" rowspan="1" colspan="1">13/25</td><td align="center" valign="top" rowspan="1" colspan="1">33/34</td><td align="center" valign="top" rowspan="1" colspan="1">(24/25)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 4</td><td align="center" valign="top" rowspan="1" colspan="1">3</td><td align="center" valign="top" rowspan="1" colspan="1">24/25</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">33/34</td><td align="center" valign="top" rowspan="1" colspan="1">(24/25)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 5</td><td align="center" valign="top" rowspan="1" colspan="1">2</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">0/7</td><td align="center" valign="top" rowspan="1" colspan="1">(0/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 6</td><td align="center" valign="top" rowspan="1" colspan="1">1</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">0/7</td><td align="center" valign="top" rowspan="1" colspan="1">(0/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 7</td><td align="center" valign="top" rowspan="1" colspan="1">N/A</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">0/5</td><td align="center" valign="top" rowspan="1" colspan="1">0/7</td><td align="center" valign="top" rowspan="1" colspan="1">(0/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 8</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">7/7</td><td align="center" valign="top" rowspan="1" colspan="1">(5/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 9</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">7/7</td><td align="center" valign="top" rowspan="1" colspan="1">(5/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Drape 1</td><td align="center" valign="top" rowspan="1" colspan="1">N/A</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">7/7</td><td align="center" valign="top" rowspan="1" colspan="1">(5/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Drape 2</td><td align="center" valign="top" rowspan="1" colspan="1">N/A</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">5/5</td><td align="center" valign="top" rowspan="1" colspan="1">7/7</td><td align="center" valign="top" rowspan="1" colspan="1">(5/5)<sup><xref rid="TFN4" ref-type="table-fn">a</xref></sup></td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr></tbody></table><table-wrap-foot><fn id="TFN3"><p id="P44"><italic toggle="yes">Note</italic>: PB70 levels for the materials are included, unless there was no indication of level (N/A). In cases in which there were mixed results (i.e., not all P or F for specimens 2, 3, and 4), a higher number of specimens was run to provide statistical significance. Different numbers of specimens were run for the ASTM and the dot-blot tests so that the total surface area tested was equivalent.</p></fn><fn id="TFN4"><label>a</label><p id="P45">Results reported in number of dot-blot actual tests <italic toggle="yes">n</italic>/7 and converted to equivalencies with comparable area (<italic toggle="yes">n</italic>/5) to facilitate statistical comparison with ASTM data.</p></fn></table-wrap-foot></table-wrap><table-wrap position="float" id="T4"><label>TABLE 4</label><caption><p id="P46">Results of PPE testing using the dot-blot apparatus for blood test soil with dye, blood test soils without dye but with the labeled protein (GaR IgG-HRP), and vomit test soils</p></caption><table frame="hsides" rules="groups"><colgroup span="1"><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/><col align="left" valign="middle" span="1"/></colgroup><thead><tr><th align="left" valign="top" rowspan="1" colspan="1">Fabric</th><th align="center" valign="top" rowspan="1" colspan="1">Level</th><th align="center" valign="top" rowspan="1" colspan="1">Blood</th><th align="center" valign="top" rowspan="1" colspan="1">Labeled Protein</th><th align="center" valign="top" rowspan="1" colspan="1">Vomit</th><th align="center" valign="top" rowspan="1" colspan="1">Blood versus Labeled Protein (<italic toggle="yes">p</italic> &#x02264; 0.05)</th><th align="center" valign="top" rowspan="1" colspan="1">Blood versus Vomit (<italic toggle="yes">p</italic> &#x02264; 0.05)</th><th align="center" valign="top" rowspan="1" colspan="1">Labeled Protein versus Vomit (<italic toggle="yes">p</italic> &#x02264; 0.05)</th></tr></thead><tbody><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 1</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 2</td><td align="center" valign="top" rowspan="1" colspan="1">3</td><td align="center" valign="top" rowspan="1" colspan="1">668/672</td><td align="center" valign="top" rowspan="1" colspan="1">558/672</td><td align="center" valign="top" rowspan="1" colspan="1">316/672</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 3</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">671/672</td><td align="center" valign="top" rowspan="1" colspan="1">669/672</td><td align="center" valign="top" rowspan="1" colspan="1">665/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 4</td><td align="center" valign="top" rowspan="1" colspan="1">3</td><td align="center" valign="top" rowspan="1" colspan="1">671/672</td><td align="center" valign="top" rowspan="1" colspan="1">670/672</td><td align="center" valign="top" rowspan="1" colspan="1">441/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 5</td><td align="center" valign="top" rowspan="1" colspan="1">2</td><td align="center" valign="top" rowspan="1" colspan="1">0/672</td><td align="center" valign="top" rowspan="1" colspan="1">0/672</td><td align="center" valign="top" rowspan="1" colspan="1">0/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 6</td><td align="center" valign="top" rowspan="1" colspan="1">1</td><td align="center" valign="top" rowspan="1" colspan="1">171/672</td><td align="center" valign="top" rowspan="1" colspan="1">0/672</td><td align="center" valign="top" rowspan="1" colspan="1">0/672</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">yes</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 7</td><td align="center" valign="top" rowspan="1" colspan="1">N/A</td><td align="center" valign="top" rowspan="1" colspan="1">3/672</td><td align="center" valign="top" rowspan="1" colspan="1">0/672</td><td align="center" valign="top" rowspan="1" colspan="1">1/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 8</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Gown 9</td><td align="center" valign="top" rowspan="1" colspan="1">4</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Drape 1</td><td align="center" valign="top" rowspan="1" colspan="1">N/A</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr><tr><td align="left" valign="top" rowspan="1" colspan="1">Drape 2</td><td align="center" valign="top" rowspan="1" colspan="1">N/A</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">672/672</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td><td align="center" valign="top" rowspan="1" colspan="1">&#x02026;</td></tr></tbody></table><table-wrap-foot><fn id="TFN5"><p id="P47"><italic toggle="yes">Note</italic>: All specimens were run, <italic toggle="yes">n</italic> = 7, at 2 psi except ISO blood for specimens 2, 3, and 4; <italic toggle="yes">n</italic> = 34 (<xref rid="T2" ref-type="table">Table 2</xref>). The results of the different test soils used with the dot-blot apparatus were converted to the number of individual wells that passed the test soil challenge (7 tests &#x000d7; 96 wells per test = 672 wells total). Statistical comparison of the different test soils for fabrics 1&#x02013;4, 6, and 7 are delineated on the right.</p></fn></table-wrap-foot></table-wrap></floats-group></article>