Personal Author:McKay, Susannah L. ; Tobolowsky, Farrell A. ; Moritz, Erin D. ; Hatfield, Kelly M. ; Bhatnagar, Amelia ; LaVoie, Stephen P. ; Jackson, David A. ; Lecy, K. Danielle ; Bryant-Genevier, Jonathan ; Campbell, Davina ; Freeman, Brandi ; Gilbert, Sarah E. ; Folster, Jennifer M. ; Medrzycki, Magdalena ; Shewmaker, Patricia L. ; Bankamp, Bettina ; Radford, Kay W. ; Anderson, Raydel ; Bowen, Michael D. ; Negley, Jeanne ; Reddy, Sujan C. ; Jernigan, John A. ; Brown, Allison C. ; McDonald, L. Clifford ; Kutty, Preeta K.
-
Corporate Authors:
-
Description:Background:
To address high COVID-19 burden in U.S. nursing homes, rapid SARS-CoV-2 antigen tests have been widely distributed in those facilities. However, performance data are lacking, especially in asymptomatic people.
Objective:
To evaluate the performance of SARS-CoV-2 antigen testing when used for facility-wide testing during a nursing home outbreak.
Design:
A prospective evaluation involving 3 facility-wide rounds of testing where paired respiratory specimens were collected to evaluate the performance of the BinaxNOW antigen test compared with virus culture and real-time reverse transcription polymerase chain reaction (RT-PCR). Early and late infection were defined using changes in RT-PCR cycle threshold values and prior test results.
Setting:
A nursing home with an ongoing SARS-CoV-2 outbreak.
Participants:
532 paired specimens collected from 234 available residents and staff.
Measurements:
Percentage of positive agreement (PPA) and percentage of negative agreement (PNA) for BinaxNOW compared with RT-PCR and virus culture.
Results:
BinaxNOW PPA with virus culture, used for detection of replication-competent virus, was 95%. However, the overall PPA of antigen testing with RT-PCR was 69%, and PNA was 98%. When only the first positive test result was analyzed for each participant, PPA of antigen testing with RT-PCR was 82% among 45 symptomatic people and 52% among 343 asymptomatic people. Compared with RT-PCR and virus culture, the BinaxNOW test performed well in early infection (86% and 95%, respectively) and poorly in late infection (51% and no recovered virus, respectively).
Limitation:
Accurate symptom ascertainment was challenging in nursing home residents; test performance may not be representative of testing done by nonlaboratory staff.
Conclusion:
Despite lower positive agreement compared with RT-PCR, antigen test positivity had higher agreement with shedding of replication-competent virus. These results suggest that antigen testing could be a useful tool to rapidly identify contagious people at risk for transmitting SARS-CoV-2 during nascent outbreaks and help reduce COVID-19 burden in nursing homes.
Primary Funding Source:
None.
-
Subjects:
-
Source:Ann Intern Med. 2021;
-
Pubmed ID:33900791
-
Pubmed Central ID:PMC8108910
-
Document Type:
-
Collection(s):
-
Main Document Checksum:urn:sha256:50b7b1ffffd7daf1135807a111faa49545a79f3c05c78bca34925ba04f84cb78
-
Download URL:
-
File Type:
Supporting Files
File Language:
English
ON THIS PAGE
CDC STACKS serves as an archival repository of CDC-published products including
scientific findings,
journal articles, guidelines, recommendations, or other public health information authored or
co-authored by CDC or funded partners.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
As a repository, CDC STACKS retains documents in their original published format to ensure public access to scientific information.
You May Also Like
COLLECTION
CDC Public Access