Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

An analyzer for determining helium-4 in the parts-per-billion range

Filetype[PDF-601.99 KB]


  • English

  • Details:

    • Personal Author:
    • Description:
      "The Bureau of Mines has developed a trace helium analyzer for determining helium-4 in the parts-per-billion range. The instrument is used for analyzing pure gases, laboratory-prepared standards, and atmospheric samples. Accuracy at the 95-pct confidence level in the 50- to 20,000-ppb range is within +/-2 ppb or +/-0.4 pct, whichever is greater. The minimum detectable helium-4 concentration is calculated to be 5 ppb. The analyzer consists of a modified helium leak-detector mass spectrometer, a laboratory-built sample inlet system, and a liquid-nitrogen-cooled charcoal trap. A programmable integrator and event-control module make automatic operation possible. The portability of the analyzer allows it to be used in the field.The Bureau of Mines has developed a trace helium analyzer for determining helium-4 in the parts-per-billion range. The instrument is used for analyzing pure gases, laboratory-prepared standards, and atmospheric samples. Accuracy at the 95-pct confidence level in the 50- to 20,000-ppb range is within +/-2 ppb or +/-0.4 pct, whichever is greater. The minimum detectable helium-4 concentration is calculated to be 5 ppb. The analyzer consists of a modified helium leak-detector mass spectrometer, a laboratory-built sample inlet system, and a liquid-nitrogen-cooled charcoal trap. A programmable integrator and event-control module make automatic operation possible. The portability of the analyzer allows it to be used in the field." - NIOSHTIC-2

      NIOSH no. 10003355

    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov