Welcome to CDC stacks | Dust Considerations When Using Belt Entry Air To Ventilate Work Areas - 10098 | National Institute for Occupational Safety and Health
Stacks Logo
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.
 
 
Help
Clear All Simple Search
Advanced Search
Dust Considerations When Using Belt Entry Air To Ventilate Work Areas
  • Published Date:
    1/1/2010
Filetype[PDF-436.53 KB]


Details:
  • Description:
    In this U.S. Bureau of Mines study, four underground respirable dust surveys were conducted to determine factors affecting belt entry dust levels and how using belt air to ventilate work areas affected dust exposures. Belt entry dust levels on the surveyed longwall and continuous miner sections averaged 0.59 and 0.26 mg/m3, respectively. The stageloader-crusher contributed an additional 0.5 to 0.9 mg/m3 of dust to belt air, while the feeder-breaker contributed 0 to 0.2 mg/m3 of dust. A 1,000-ft increase in belt entry length or a 200-to 500-st-per-shift increase in production resulted in roughly a 0.1-mg/m3 increase in dust. Using the belt entry as an intake entry on the continuous miner section appeared to reduce dust levels by 0.1 to 0.3 mg/m3 during cutting. Belt air was not used to ventilate the face on the longwall section.

  • Supporting Files:
    No Additional Files
No Related Documents.