Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

A model of shield-strata interaction and its implications for active shield setting requirements

Filetype[PDF-1.25 MB]


  • English

  • Details:

    • Personal Author:
    • Description:
      "This U.S. Bureau of Mines study evaluates factors that influence longwall support and strata interaction. The longwall system is composed of an immediate and main roof structure and three supporting foundations: longwall panel, powered roof supports, and gob waste. The main roof forms a structure that is generally supported by all three foundations, while the immediate roof acts as a beam that cantilevers from the coal face to the powered support. In most cases, shield loading involves a complex interaction of both main roof and immediate roof behavior and is a combination of loads produced from convergence of the main roof and displacements of the immediate roof caused by deformations of the cantilevered roof beam. Since the shield stiffness remains constant for all leg pressures and main roof convergence is irresistible in terms of shield capacity, the shield must be able to control the behavior of the immediate roof or floor structure for shield loading to be sensitive to setting pressures. If the goal is to minimize total shield loading, any active setting force must be offset by reduced passive shield loading to justify the active setting loads. Field data suggest that the typical reductions in passive loading do not justify the required increases in setting pressure in some applications." - NIOSHTIC-2

      NIOSH no. 10011078

    • Document Type:
    • Main Document Checksum:
    • File Type:

    Supporting Files

    • No Additional Files

    More +

    You May Also Like

    Checkout today's featured content at stacks.cdc.gov