A Field Study of Longwall Mine Ventilation Using Tracer Gas in a Trona Mine
Advanced Search
Select up to three search categories and corresponding keywords using the fields to the right. Refer to the Help section for more detailed instructions.

Search our Collections & Repository

All these words:

For very narrow results

This exact word or phrase:

When looking for a specific result

Any of these words:

Best used for discovery & interchangable words

None of these words:

Recommended to be used in conjunction with other fields

Language:

Dates

Publication Date Range:

to

Document Data

Title:

Document Type:

Library

Collection:

Series:

People

Author:

Help
Clear All

Query Builder

Query box

Help
Clear All

For additional assistance using the Custom Query please check out our Help Page

i

A Field Study of Longwall Mine Ventilation Using Tracer Gas in a Trona Mine

Filetype[PDF-2.31 MB]


  • English

  • Details:

    • Alternative Title:
      Min Metall Explor
    • Description:
      A ventilation research study was conducted by the National Institute for Occupational Safety and Health and a cooperating trona mine in the Green River basin of Wyoming, USA. The mine operation uses the longwall mining method in trona bed 17, a commonly mined unit in the region. The longwall face length is 228 m (750 ft), and caving on the face occurred up to the back of the longwall shields. The mine is ventilated using a main blowing fan and a bleeder shaft. For this study, sulfur hexafluoride (SF|) tracer gas was released in two separate monitoring experiments. For the first experiment, tracer gas was released on the face, this test focused on airflow along the longwall face of the active panel. Face test showed the airflow patterns to be more complex than just head-to-tail flow in the main ventilation air stream on the active panel. For the second experiment, tracer gas was released 2 crosscuts inby the face on the headgate side, this test focused on gas transport in the mined-out portion of the same active panel. Gob test showed a pathway of movement through the front of the active panel gob that moved outby from the tailgate corner. The primary pathway of tracer gas movement in the active panel gob was towards the headgate and tailgate bleeders and out of a bleeder shaft. The rate of movement towards the back of the gob was measured to be 0.19 m/s (37 fpm).
    • Subjects:
    • Pubmed ID:
      31768500
    • Pubmed Central ID:
      PMC6876311
    • Document Type:
    • Collection(s):
    • Main Document Checksum:
    • File Type:

    You May Also Like